STATEMENT OF WORK FOR
LRTI Replacemnt
1. SCOPE: The NH Air National Guard, 157th Security Forces Squadron, requires that two of existing thermal imagers for the PL3 area be replaced.
The NH NG contracting office intends to make a single award of a Firm Fixed Price contract for product(s) as stated on the requisition request to upgrade 2 existing General Dynamics Long Range Thermal Imagers (LRTI) to the FLIR DefendIR MS-UC 640 thermal camera system. All deliveries shall be provided to NH Air National Guard, 157 SFS/S5, 302 Newmarket St – Bld 257, Portsmouth NH 03803 unless specifically authorized.
2. LOCATION: Portsmouth International Airport at Pease, Portsmouth, New Hampshire.
2.1 Product(s) to be delivered to TSgt Derek Arsenault, 157 Security Forces Squadron, 302 Newmarket St – Bld 257, Portsmouth NH 03803.
3. DESCRIPTION OF REQUEST:
3.1 Two DefendIR MS-UC 640 cameras, with two pedestal heaters and pedestal heater cables, eight ADI GE-32711TP BNC-F to BNC-F connector 10 PK, and any other associated wiring/equipment to complete installation and connection into existing system.
3.2 Existing General Dynamics LRTI system removed an stored at BLDG 257.
3.3 Installation and connection must be done by an Advantor Systems certified company or sub-contract Advantor Systems to conduct installation.
3.4 Connection to the existing Video Management System (VMS) must be done by Advantor Systems.
3.5 Camera locations are sixty (60) feet in the air, a lift will be required to conduct installation.
3.6 A technical review is required when reviewing alternate solutions to ensure existing system compatibility.
3.7 1 Year enhanced warranty service.