A07_Drawings_-_Work_Locations_AXQD152009.pdf
PDF 9 MB Posted
- Attached to
- Repair Maintenance Electrical Interlock Connections Federal contract opportunity
- Solicitation number
- W912SV-16-T-0026
About this file
Drawings - Work Locations AXQD152009
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A07_Site_Visit_Sign-In_W912SV-16-T-0026_-_Install_Interlock_Connectors.pdf | ||
| Solicitation_QA_20160910.pdf | ||
| A07_252.225-7035_Alt_I.pdf | ||
| A01_AXQD152009_Repair_Interlock_Receptacles_SOW.pdf | ||
| Contractor_Entry_Authority_List.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N/A
023020
046 047 045013
N/A
N/A
Blast Wall
Blast Wall
Blast Wall
206206
N/A
Blast Wall
ITN
N/A gazebo
Lox Shed
N/A
FL I.A.P.
N/A
ACA_I.A.P.
BARNES AIR NATIONAL GUARD BASE
Westfield, Ma. 01085 Installation Map -( for general orientation only) Imagery from MassGIS dated 2013 Plot Date: May 2014 Plot Scale: N.T.S.
Blg 001 Operations and Training Blg 003 Dining Facility Blg 008 E.M. / NCO Club Blg 010 Liquid Fuels Storage Blg 012 Mobility Processing/gym/chaplain Blg 013 Ready Shelter Blg 015 Main Hangar Blg 016 Heating Facil ity Blg 017 Supply Warehouse Blg 019 Ready Shelter Blg 020 AGE/Engine/ NDI Shop Blg 021 Warehouse Blg 023 Weapons Release Hangar
Blg 025 Squadron Operations Blg 026 Avionics/Structural shop Blg 027 Fuels/Corrision Hangar Blg 028 Aircraft general purpose Blg 029 Clinic/Communications Blg 030 Main Gate Blg 031 Security Forces Blg 032 Communications Accessory Blg 033 POL Operations Blg 034 POL Fueling Control Blg 035 POL Fueling Pump house Blg 036 Transition Blg 037 Tool Kit Storage
Blg 038 Lox Storage Blg 039 Lox Office Blg 040 CE/Fire dept Blg 041 Sewage Lift Station Blg 042 CE Warehouse Blg 043 Sand/Salt storage Blg 044 EOD Blg 045-047 ACA Alert Hangar Blg 048 ACA Crew Quarters Blg 049 ACA ECP Blg 052 Hazmat Blg 053 Cylinder Storage Blg 054 Base Supply
Blg 055 Vehicle Maint Blg 056 CE Snow Storage Blg 058 ParkingShed Blg 070 Jet Engine Storage Blg 071 AGE Maint Storage Blg 077 Security/ FSS Blg 082 ACA Fire Pump House Blg 116 Drop Tank Storage Blg 401 Snow Equipment Building
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Rectangle
1254046139N Rectangle
1254046139N Rectangle
1254046139N Rectangle
1254046139N Callout 6 replacement
NO DEMOLITION
1254046139N Callout 4 demo 4 replacement
1254046139N Callout 1 replacement
1254046139N Callout 2 replacements
1254046139N Text Box
AXQD152009
GENERAL NOTES
1. Work in all areas will require an escort
J M JM
T
T
M
J
J
J M
J
SS
H
SS
J
T J M
S
J
S
H
MD MD
LP1-1
LP1-2
LP1-5
LP1-3
HP1-20,22,24
LP1-4
HP1-50,52,54HP1-49,51,53
LPI-6
HP1-25,27,29
LP1-16LP1-24
LP1-10HP1-26,28,30
HP1-43,45,47
LP1-22
HP1-44,46,48
F
HP1-
38,40,42
HP1-
14,16,18
HP1-
31,33,35
HP1-
8,10,12
LP1-18
J
J
C O P Y R
IG
H
B U
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
APRIL 13, 2010 K. DISPOTO
H. MATIC T. PARADEIS
FLOOR PLAN
AIRCRAFT SHELTER NO. 1
POWER AND GROUNDING
E102 1
55996E102.DWG
16'8'4'0
SCALE IN FEET
CONNECT TO SHELTER
NO. 2 GROUND GRID CONNECT TO SHELTER
NO. 2 GROUND GRID
GFI,
WPIU
GFI,
WPIU
GFI,WPIU
GFI, WPIU
GFI,
WPIU
S ca le F or M ic ro fil m in g
In ch es M ill im et er s
no. date descriptionby
1 1615141312111098765432 17
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd
C O P Y R
IG
H
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
BARNES AIR NATIONAL GUARD BASE
104th FIGHTER WING
175 FALCON DRIVE
WESTFIELD, MASS. 01085
C O P Y R
IG
H
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
AIRCRAFT READY SHELTERS
AXQD08907055996
E503
E501
E401
PRE-
CONDITIONING
AIR UNIT 1-2 4
PRE-
CONDITIONING
AIR UNIT 1-1
E503
#2 AWG
BARE COPPER
E501
E503E501
#6 AWG IN
3/4" CONDUIT
26 EF-1
UH-1
EF-2
UH-2
PRE- CONDITIONING
AIR UNIT 1-4
19DS#1-4
GFI,
WPIU
DS#1-3
PRE- CONDITIONING
AIR UNIT 1-3
#2 AWG
BARE COPPER
#2 AWG
BARE COPPER
240V/1P/NEMA 3R/5 6
FRN-R FUSES
AD-1 (AIR DRYER)
CA-1 (AIR COMPRESSOR)
SEE NOTE 6,
TYPICAL
HEF FOAM
DISPENSERS,
TYPICAL
ABC
A.7B.3
A.3B.7
TO DISC SW
DS1-S
TO DISC SW
DS1-N
WP
WP
21 32
E503
0 ISSUED FOR BIDTPHM
ISSUED FOR
CONSTRUCTION
HM
2-BAY AIRCRAFT
READY SHELTERS
FOAM
ROOM
ELEC/COMM
ROOM
POWER AND GROUNDING
AIRCRAFT SHELTER NO. 1
FLOOR PLAN
TYPICAL
TYPICAL
WP
1. CONTRACTOR SHALL WIRE AND INSTALL MANUFACTURER'S
FURNISHED CONTROL PANELS, MOTOR AND CONTROL
DEVICES, SENSORS, SAFETY DEVICES, ETC. THE
CONTRACTOR IS ALSO RESPONSIBLE IN PROVIDING FIELD
WIRING FROM CONTROL PANELS TO MOTORS, CONTROL
DEVICES, SENSORS, ETC PER MANUFACTURER'S WIRING
DIAGRAM. ALL WIRING SHALL BE IN MINIMUM 3/4" CONDUIT.
COMPLY WITH NEC ARTICLE 513 FOR ANY ELECTRICAL
WORK WITHIN AIRCRAFT 5'-0" [1524] ENVELOPE, SEE
DRAWING E101.
2. COORDINATE WITH OTHER TRADES AS TO THE EXACT
LOCATION OF THEIR RESPECTIVE EQUIPMENT. SUPPLY
POWER AND MAKE CONNECTION TO MOTORS AND
EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS AS
INDICATED ON THE SINGLE LINE DIAGRAM, ELECTRICAL
DRAWINGS, AND DRAWINGS OF OTHER TRADES. REVIEW
THE DRAWINGS OF OTHER TRADES FOR CONTROL
DIAGRAMS, SIZE AND LOCATION OF EQUIPMENT. UNLESS
PROVIDED BY EQUIPMENT MANUFACTURER DISCONNECT
SWITCHES, STARTERS, WIRING, CONTROLS AND CONDUIT
FOR MECHANICAL, FIRE PROTECTION AND PLUMBING
OPERATIONS SHALL BE PROVIDED. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING ENGINEER'S
APPROVED MANUFACTURER SHOP DRAWINGS PRIOR TO
ROUGHING IN ALL CONDUITS TO EQUIPMENT.
3. ALL EQUIPMENT, DEVICES AND WIRING IN AIRCRAFT
SHELTER BAYS AND HEF FOAM ROOM SHALL BE IN NEMA 3R
INSTALLATION UNLESS OTHERWISE NOTED.
4. ALL WIRING SHALL BE ABOVEGROUND. NO WIRING IN SLAB
OR BELOW SLAB ALLOWED UNLESS OTHERWISE NOTED.
5. INTERLOCK THE INFRA-RED HEATING SYSTEM WITH
AIRCRAFT SHELTER BAY DOOR OPERATION SO THE
HEATING IS INOPERATIVE WHEN DOORS ARE OPEN.
6. ACTIVATION OF HIGH EXPANSION FOAM SYSTEM SHALL
SHUT-DOWN SHELTER OVERHEAD INFRA-RED HEATING
SYSTEM AND FANS.
7. ALL ELECTRICAL EQUIPMENT IN SHELTER BAY AREAS SHALL
BE MOUNTED MINIMUM 4'-0" [1219] FROM BOTTOM OF
EQUIPMENT TO FINISHED FLOOR, UON.
NOTES:
WP
LV1-2
TYPICAL
TYPICAL
DS#1-2
DS#1-1
WP
TYPICAL
TYPICAL
SEE NOTES 5 AND 6
LV1-1 LV1-3
DOOR HEADER JUNCTION BOX
DOOR DRIVE MOTOR. COORDINATE EXACT LOCATION IN THE FIELD.
REMOTE DOOR PUSHBUTTON, WEATHER PROOF. COORDINATE
EXACT LOCATION WITH CONTRACTING OFFICER. MOUNTING HEIGHT
MINIMUM 4'-0" [1219] FROM BOTTOM OF ENCLOSURE TO FINISHED
FLOOR, TYPICAL.
CONVENIENCE OUTLET, COMMERCIAL GRADE, GROUND FAULT
CIRCUIT INTERRUPTER, 20A, 125V, WITH WEATHERPROOF
WHILE-IN-USE METAL COVER. MINIMUM MOUNTING HEIGHT 4'-0"
[1219] AFF/AFG TO BOTTOM OF DEVICE'S BOX. MOUNT 5'-0" [1520]
AFG IN HEF FOAM ROOM AREA.
SHELTER BAY MEGADOOR DOOR CONTROL PANEL,
WEATHERPROOF. MOUNTING HEIGHT MINIMUM 4'-0" [1219] AFF TO
BOTTOM OF CONTROL PANEL. COORDINATE EXACT LOCATION WITH
CONTRACTING OFFICER, TYPICAL.
LIGHTNING DOWN CONDUCTOR FROM ROOF TOP. SEE LIGHTNING
PROTECTION PLAN ON DRAWING E104.
EXOTHERMICALLY WELD GROUND CONDUCTOR TO EACH GROUND
ROD AND BUILDING STRUCTURAL STEEL BEAM.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR BURIED
2'-6" [762] MIN. BELOW GRADE AND MIN. OF 3'-0" [914] TO 8'-0" [2438]
AWAY FROM BUILDING FOUNDATION.
JUNCTION BOX FOR CAMERA POWER. COORDINATE WITH BASE
COMMUNICATION GROUP EXACT LOCATION AND MOUNTING HEIGHT
OF ALL CAMERA INSTALLATIONS. SEE INTRUSION DETECTION RISER
ON DRAWING E603 AND EQUIPMENT SPECIFICATIONS FOR
ADDITIONAL DETAILS.
TIN PLATED STATIC DISCHARGE TOUCH PLATE 4"x8"x1/4" [102x203x6]
MOUNTED NEXT TO DOOR STRIKE 4'-0" [1220] ABOVE THRESHOLD
UON. CONNECT TO GROUND ELECTRODE WITH #2 AWG COPPER
CONDUCTOR WITH EXOTHERMIC WELDS BOTH ENDS.
PROVIDE 24VDC POWER SUPPLY TRANSFORMER IN NEMA 3R
ENCLOSURE FOR SECURITY DEVICES. MOUNT 22'-0" [6706] AFF.
REFER TO DETAIL 7 DRAWING E501 FOR FURTHER INFORMATION.
200A, 3-POLE, 600V, PRE-CONDITION AIR UNIT OUTDOOR
RECEPTACLE. COORDINATE REQUIRED OUTLET CURRENT RATING
AND CONFIGURATION WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION, AND THE LOCATION WITH ARCHITECTURAL WORK.
TIN PLATED GROUND BAR MOUNT 2'-'0" [610] AFF. SEE DETAIL 6 ON
DRAWING E503.
INFRA-RED HEATING CONTROL PANEL, WEATHERPROOF, PROVIDED
UNDER MECHANICAL WORK. MOUNTING HEIGHT MINIMUM 4'-0" [1219]
AFF TO BOTTOM OF CONTROL PANEL. REFER TO MECHANICAL
DRAWING FOR EXACT LOCATION.
400 HZ CABLE ASSEMBLY WALL MOUNTED ALUMINUM CORD HOLDER.
WALL MOUNTED HOLDER SHALL WITHSTAND 250 LBS. CORD WEIGHT.
400 HZ CABLE ASSEMBLY IS GOVERNMENT FURNISHED
CONTRACTOR INSTALLED. COORDINATE CABLE HOLDER LOCATION
WITH CONTACTING OFFICER.
GOVERNMENT FURNISHED CONTRACTOR INSTALLED 62.5 KVA
400 HZ CONVERTER. 480V INPUT, 200Y/115V OUTPUT.
3#1/0 AWG, 1#6 GND - 2" CONDUIT.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR TO
AIRCRAFT GROUNDING RECEPTACLES AND AGE GROUNDING
POINTS. SEE DRAWING E005 FOR CONTINUATION.
200A, 600V, 3-POLE, 3-WIRE, NEMA 3R NON-FUSED DISCONNECT
SWITCH. MOUNT DISCONNECT WITH MINIMUM 4'-0" [1219] AFF TO
BOTTOM OF SWITCH ENCLOSURE.
12 FOOT [3658] ROLL-UP DOOR CONTROL PANEL, WEATHERPROOF.
MOUNTING HEIGHT MINIMUM 4'-0" [1219] AFF TO BOTTOM OF
CONTROL PANEL.
SHELTER BAY DOOR REMOTE FIREMAN'S SELECTOR SWITCH TO
OPEN NORTH OR SOUTH AIRCRAFT BAY DOOR. MOUNTING HEIGHT
MINIMUM 4'-0" [1219] AFG TO BOTTOM OF DEVICE ENCLOSURE. FINAL
LOCATION SHALL BE COORDINATED WITH CONTRACTING OFFICER.
OMNIDIRECTIONAL ANTENNA, OUTDOOR ON UPPER ROOF. SEE
DETAIL 3 ON DRAWING E502. COORDINATE LOCATION WITH VENDOR
AND BASE COMMUNICATION GROUP.
ANTENNA CABLE SURGE SUPPRESSION DEVICE IN NEMA 3R
ENCLOSURE AND BOND GROUNDING CONDUCTOR ON THE GROUND
RING. MOUNT DEVICE PER ANTENNA FIRE ALARM VENDOR
RECOMMENDATION.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR TO
MANHOLES, HANDHOLES, ALONGSIDE OF UNDERGROUND
DUCTBANKS AND TRANSFORMER 'T1'.
PROVIDE DISCONNECT SWITCH. COORDINATE DISCONNECT SWITCH
LOCATION WITH THE UNIT IT PROTECTS.
DISCONNECT SWITCH PROVIDED BY UNIT MANUFACTURER.
PROVIDE 20A, 120V, GROUNDING TYPE, HORSEPOWER RATED
TOGGLE SWITCH AS A UNIT DISCONNECT SWITCH.
VACUUM PUMP INFRA-RED HEATING SYSTEM. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK. CONTROL WIRING BETWEEN
INFRARED CONTROLLER, VACUUM PUMP, ETC SHALL BE PROVIDED
BY CONTRACTOR.
INFRA-RED HEATING SYSTEM SENSOR. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK.
OVERHEAD FAN CONTROLLER CABLE IN 3/4"C. COORDINATE
CONTROLLER CABLE REQUIREMENT UNDER MECHANICAL WORK.
OVERHEAD FAN PROVIDED UNDER MECHANICAL WORK COORDINATE
FINAL LOCATION.
PROVIDE AN ENGRAVED SIGN IN WHITE LETTER 1/4" HIGH IN BLACK
BACKGROUND, PERMANENTLY AFFIXED ON THE FRONT OF THE
EQUIPMENT AND VISIBLE. SIGN READS "WARNING: DO NOT OPERATE
PRE-CONDITIONING AIR UNITS 1-1 AND 1-4. SIMULTANEOUSLY, IT
WILL TRIP THE CIRCUIT BREAKER AND OVERHEAT CONDUCTORS."
INSTALL IN WEATHERPROOF FOR OUTDOOR EQUIPMENT, TYPICAL
FOR PRE-CONDITIONING AIR UNITS 1-2 AND 1-3.
OVERHEAD FAN CONTROLLERS IN NEMA 3R ENCLOSURE. PROVIDE
NEMA 3R HINGED-COVER LIFT-OFF ENCLOSURE. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK. ENCLOSURE REQUIRES
ENGINEER'S APPROVAL PRIOR TO INSTALLATION.
KEYED NOTES:
VF-2
WP
VF-1
WP
SEE
ENLARGED
PLAN
WP
WP
HM09/21/10 EI ADDENDUM #2
WP
I:\USAIRNG\55996\CAD\ELEC\55996E102.DWG 10/13/2010 8:54 AM KDISPOTO
General Notes for AXQD152009 Repair MXG Interlock Receptacles
1. All exterior receptacles to be demolished.
2. Exterior penetrations to be covered. Match existing.
3. Interlock Receptacles to be:
Crouse-Hinds EPC.... or equal
4. Interlock Receptacles installed with:
Push-Button ON/OFF LED Light Indicators ON/OFF
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Callout Move receptacle inside
1254046139N Callout Move receptacle inside
1254046139N Callout Demolish receptacle, conduit, wires back to panel
1254046139N Callout Demolish receptacle, conduit, wires back to panel
1254046139N Highlight
1254046139N Highlight
J M JM
T
M
J
J
J M
J
SS
H
MD
SS
J
T J M
MD S
J
S
H
LP2-5
LP2-3
LP2-10HP2-26,28,30
HP2-20,22,24
LP2-22
HP2-43,45,47
HP2-50,52,54HP2-49,51,53
LP2-6
HP2-25,27,29
LP2-16
LP2-18
HP2-44,46,48
F
HP2-
38,40,42
HP2-
8,10,12
HP2-
31,33,35
HP2-
14,16,18
LP2-1
LP2-2
LP2-4
LP2-24
J
J
C O P Y R
IG
H
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
APRIL 13, 2010 K. DISPOTO
H. MATIC T. PARADEIS
FLOOR PLAN
AIRCRAFT SHELTER NO. 2
POWER AND GROUNDING
E103 1
55996E103.DWG
16'8'4'0
SCALE IN FEET
S ca le F or M ic ro fil m in g
In ch es M ill im et er s
no. date descriptionby
1 1615141312111098765432 17
M
L
K
J
I
H
G
F
E
D
C
B
A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd
C O P Y R
IG
H
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
BARNES AIR NATIONAL GUARD BASE
104th FIGHTER WING
175 FALCON DRIVE
WESTFIELD, MASS. 01085
C O P Y R
IG
H
R N
S
M cD
O N
N E
LL
E
N G
IN
E
E R
IN
G
C O
M P
A N
Y , I
N C
AIRCRAFT READY SHELTERS
AXQD08907055996
CONNECT TO SHELTER
NO. 1 GROUND GRID CONNECT TO SHELTER
NO. 1 GROUND GRID
GFI,
WPIU
GFI,
WPIU
GFI,WPIU
GFI, WPIU
E501
PRE-
CONDITIONING
AIR UNIT 2-2
PRE-
CONDITIONING
AIR UNIT 2-1
E503
#2 AWG
BARE COPPER
E503
#6 AWG IN
3/4" CONDUIT
EF-3
UH-3
EF-4
UH-4
12PRE- CONDITIONING
AIR UNIT 2-4
19DS#2-4
GFI,
WPIU
DS#2-3
PRE- CONDITIONING
AIR UNIT 2-3
#2 AWG
BARE COPPER#2 AWG
BARE COPPER
240V/1P/NEMA 3R/5 6
FRN-R FUSES
AD-2 (AIR DRYER)
CA-2 (AIR COMPRESSOR)
SEE NOTE 6,
TYPICAL
E501
GFI,
WPIU
101HEF FOAM
DISPENSERS,
TYPICAL
ABC
A.7B.3
A.3B.7
TO DISC SW
DS2-S
WP
WP
TO DISC SW
DS2-N
E503
E501
E401
21 32
E503
0 ISSUED FOR BIDTPHM
ISSUED FOR
CONSTRUCTION
HM
POWER AND GROUNDING
AIRCRAFT SHELTER NO. 2
FLOOR PLAN
1. CONTRACTOR SHALL WIRE AND INSTALL MANUFACTURER'S
FURNISHED CONTROL PANELS, MOTOR AND CONTROL
DEVICES, SENSORS, SAFETY DEVICES, ETC. THE
CONTRACTOR IS ALSO RESPONSIBLE IN PROVIDING FIELD
WIRING FROM CONTROL PANELS TO MOTORS, CONTROL
DEVICES, SENSORS, ETC PER MANUFACTURER'S WIRING
DIAGRAM. ALL WIRING SHALL BE IN MINIMUM 3/4" CONDUIT.
COMPLY WITH NEC ARTICLE 513 FOR ANY ELECTRICAL
WORK WITHIN AIRCRAFT 5'-0" [1524] ENVELOPE, SEE
DRAWING E101.
2. COORDINATE WITH OTHER TRADES AS TO THE EXACT
LOCATION OF THEIR RESPECTIVE EQUIPMENT. SUPPLY
POWER AND MAKE CONNECTION TO MOTORS AND
EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS AS
INDICATED ON THE SINGLE LINE DIAGRAM, ELECTRICAL
DRAWINGS, AND DRAWINGS OF OTHER TRADES. REVIEW
THE DRAWINGS OF OTHER TRADES FOR CONTROL
DIAGRAMS, SIZE AND LOCATION OF EQUIPMENT. UNLESS
PROVIDED BY EQUIPMENT MANUFACTURER DISCONNECT
SWITCHES, STARTERS, WIRING, CONTROLS AND CONDUIT
FOR MECHANICAL, FIRE PROTECTION AND PLUMBING
OPERATIONS SHALL BE PROVIDED. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING ENGINEER'S
APPROVED MANUFACTURER SHOP DRAWINGS PRIOR TO
ROUGHING IN ALL CONDUITS TO EQUIPMENT.
3. ALL EQUIPMENT, DEVICES AND WIRING IN AIRCRAFT
SHELTER BAYS AND HEF FOAM ROOM SHALL BE IN NEMA 3R
INSTALLATION UNLESS OTHERWISE NOTED.
4. ALL WIRING SHALL BE ABOVEGROUND. NO WIRING IN SLAB
OR BELOW SLAB ALLOWED UNLESS OTHERWISE NOTED.
5. INTERLOCK THE INFRA-RED HEATING SYSTEM WITH
AIRCRAFT SHELTER BAY DOOR OPERATION SO THE
HEATING IS INOPERATIVE WHEN DOORS ARE OPEN.
6. ACTIVATION OF HIGH EXPANSION FOAM SYSTEM SHALL
SHUT-DOWN SHELTER OVERHEAD INFRA-RED HEATING
SYSTEM AND FANS.
7. ALL ELECTRICAL EQUIPMENT IN SHELTER BAY AREAS SHALL
BE MOUNTED MINIMUM 4'-0" [1219] FROM BOTTOM OF
EQUIPMENT TO FINISHED FLOOR, UON.
NOTES:
ELEC/COMM
ROOM
TYPICAL
WP
WP
WP
WP
TYPICAL
DS#2-2
DS#2-1
WP
TYPICAL
LV2-1 LV2-3
VF-4
WP
VF-3
WP
LV2-2
FOAM
ROOM
TYPICAL
2-BAY AIRCRAFT
READY SHELTERS TYPICAL
TYPICAL
SEE NOTES 5 AND 6
SEE
ENLARGED
PLAN
DOOR HEADER JUNCTION BOX
DOOR DRIVE MOTOR. COORDINATE EXACT LOCATION IN THE FIELD.
REMOTE DOOR PUSHBUTTON, WEATHER PROOF. COORDINATE
EXACT LOCATION WITH CONTRACTING OFFICER. MOUNTING HEIGHT
MINIMUM 4'-0" [1219] FROM BOTTOM OF ENCLOSURE TO FINISHED
FLOOR, TYPICAL.
CONVENIENCE OUTLET, COMMERCIAL GRADE, GROUND FAULT
CIRCUIT INTERRUPTER, 20A, 125V, WITH WEATHERPROOF
WHILE-IN-USE METAL COVER. MINIMUM MOUNTING HEIGHT 4'-0"
[1219] AFF/AFG TO BOTTOM OF DEVICE'S BOX. MOUNT 5'-0" [1520]
AFG IN HEF FOAM ROOM AREA.
SHELTER BAY MEGADOOR DOOR CONTROL PANEL,
WEATHERPROOF. MOUNTING HEIGHT MINIMUM 4'-0" [1219] AFF TO
BOTTOM OF CONTROL PANEL. COORDINATE EXACT LOCATION WITH
CONTRACTING OFFICER, TYPICAL.
LIGHTNING DOWN CONDUCTOR FROM ROOF TOP. SEE LIGHTNING
PROTECTION PLAN ON DRAWING E104.
EXOTHERMICALLY WELD GROUND CONDUCTOR TO EACH GROUND
ROD AND BUILDING STRUCTURAL STEEL BEAM.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR BURIED
2'-6" [762] MIN. BELOW GRADE AND MIN. OF 3'-0" [914] TO 8'-0" [2438]
AWAY FROM BUILDING FOUNDATION.
JUNCTION BOX FOR CAMERA POWER. COORDINATE WITH BASE
COMMUNICATION GROUP EXACT LOCATION AND MOUNTING HEIGHT
OF ALL CAMERA INSTALLATIONS. SEE INTRUSION DETECTION RISER
ON DRAWING E603 AND EQUIPMENT SPECIFICATIONS FOR
ADDITIONAL DETAILS.
TIN PLATED STATIC DISCHARGE TOUCH PLATE 4"x8"x1/4" [102x203x6]
MOUNTED NEXT TO DOOR STRIKE 4'-0" [1220] ABOVE THRESHOLD
UON. CONNECT TO GROUND ELECTRODE WITH #2 AWG COPPER
CONDUCTOR WITH EXOTHERMIC WELDS BOTH ENDS.
PROVIDE 24VDC POWER SUPPLY TRANSFORMER IN NEMA 3R
ENCLOSURE FOR SECURITY DEVICES. MOUNT 22'-0" [6706] AFF.
REFER TO DETAIL 7 DRAWING E501 FOR FURTHER INFORMATION.
200A, 3-POLE, 600V, PRE-CONDITION AIR UNIT OUTDOOR
RECEPTACLE. COORDINATE REQUIRED OUTLET CURRENT RATING
AND CONFIGURATION WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION, AND THE LOCATION WITH ARCHITECTURAL WORK.
TIN PLATED GROUND BAR MOUNT 2'-'0" [610] AFF. SEE DETAIL 6 ON
DRAWING E503.
INFRA-RED HEATING CONTROL PANEL, WEATHERPROOF, PROVIDED
UNDER MECHANICAL WORK. MOUNTING HEIGHT MINIMUM 4'-0" [1219]
AFF TO BOTTOM OF CONTROL PANEL. REFER TO MECHANICAL
DRAWING FOR EXACT LOCATION.
400 HZ CABLE ASSEMBLY WALL MOUNTED ALUMINUM CORD HOLDER.
WALL MOUNTED HOLDER SHALL WITHSTAND 250 LBS. CORD WEIGHT.
400 HZ CABLE ASSEMBLY IS GOVERNMENT FURNISHED
CONTRACTOR INSTALLED. COORDINATE CABLE HOLDER LOCATION
WITH CONTACTING OFFICER.
GOVERNMENT FURNISHED CONTRACTOR INSTALLED 62.5 KVA
400 HZ CONVERTER. 480V INPUT, 200Y/115V OUTPUT.
3#1/0 AWG, 1#6 GND - 2" CONDUIT.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR TO
AIRCRAFT GROUNDING RECEPTACLES. SEE DRAWING E005 FOR
CONTINUATION.
200A, 600V, 3-POLE, 3-WIRE, NEMA 3R NON-FUSED DISCONNECT
SWITCH. MOUNT DISCONNECT WITH MINIMUM 4'-0" [1219] AFF TO
BOTTOM OF SWITCH ENCLOSURE.
12 FOOT [3658] ROLL-UP DOOR CONTROL PANEL, WEATHERPROOF.
MOUNTING HEIGHT MINIMUM 4'-0" [1219] AFF TO BOTTOM OF
CONTROL PANEL.
SHELTER BAY DOOR REMOTE FIREMAN'S SELECTOR SWITCH TO
OPEN NORTH OR SOUTH AIRCRAFT BAY DOOR. MOUNTING HEIGHT
MINIMUM 4'-0" [1219] AFG TO BOTTOM OF DEVICE ENCLOSURE. FINAL
LOCATION SHALL BE COORDINATED WITH CONTRACTING OFFICER.
OMNIDIRECTIONAL ANTENNA, OUTDOOR ON UPPER ROOF. SEE
DETAIL 3 ON DRAWING E502. COORDINATE LOCATION WITH VENDOR
AND BASE COMMUNICATION GROUP.
ANTENNA CABLE SURGE SUPPRESSION DEVICE IN NEMA 3R
ENCLOSURE AND BOND GROUNDING CONDUCTOR ON THE GROUND
RING. MOUNT DEVICE PER ANTENNA FIRE ALARM VENDOR
RECOMMENDATION.
#4/0 AWG BARE COPPER STRANDED GROUND CONDUCTOR TO
MANHOLES, HANDHOLES, ALONGSIDE OF UNDERGROUND
DUCTBANKS AND TRANSFORMER 'T1'.
PROVIDE DISCONNECT SWITCH. COORDINATE DISCONNECT SWITCH
LOCATION WITH THE UNIT IT PROTECTS.
DISCONNECT SWITCH PROVIDED BY UNIT MANUFACTURER.
PROVIDE 20A, 120V, GROUNDING TYPE, HORSEPOWER RATED
TOGGLE SWITCH AS A UNIT DISCONNECT SWITCH.
VACUUM PUMP INFRA-RED HEATING SYSTEM. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK. CONTROL WIRING BETWEEN
INFRARED CONTROLLER, VACUUM PUMP, ETC SHALL BE PROVIDED
BY CONTRACTOR.
INFRA-RED HEATING SYSTEM SENSOR. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK.
OVERHEAD FAN CONTROLLER CABLE IN 3/4"C. COORDINATE
CONTROLLER CABLE REQUIREMENT UNDER MECHANICAL WORK.
OVERHEAD FAN PROVIDED UNDER MECHANICAL WORK COORDINATE
FINAL LOCATION.
PROVIDE AN ENGRAVED SIGN IN WHITE LETTER 1/4" HIGH IN BLACK
BACKGROUND, PERMANENTLY AFFIXED ON THE FRONT OF THE
EQUIPMENT AND VISIBLE. SIGN READS "WARNING: DO NOT OPERATE
PRE-CONDITIONING AIR UNITS 2-1 AND 2-4. SIMULTANEOUSLY, IT
WILL TRIP THE CIRCUIT BREAKER AND OVERHEAT CONDUCTORS."
INSTALL IN WEATHERPROOF FOR OUTDOOR EQUIPMENT, TYPICAL
FOR PRE-CONDITIONING AIR UNITS 2-2 AND 2-3.
OVERHEAD FAN CONTROLLERS IN NEMA 3R ENCLOSURE. PROVIDE
NEMA 3R HINGED-COVER LIFT-OFF ENCLOSURE. COORDINATE FINAL
LOCATION WITH MECHANICAL WORK. ENCLOSURE REQUIRES
ENGINEER'S APPROVAL PRIOR TO INSTALLATION.
STAND-ALONE COMMUNICATION TOWER. BOND TOWER TO GROUND
GRID PER TOWER MANUFACTURER'S RECOMMENDATION.
KEYED NOTES:
HM09/21/10 EI ADDENDUM #2
I:\USAIRNG\55996\CAD\ELEC\55996E103.DWG 10/13/2010 8:53 AM KDISPOTO
General Notes for AXQD152009 Repair MXG Interlock Receptacles
1. All exterior receptacles to be demolished.
2. Exterior penetrations to be covered.
Match existing.
3. Interlock Receptacles to be:
Crouse-Hinds EPC.... or equal
4. Interlock Receptacles installed with:
Push-Button ON/OFF LED Light Indicators ON/OFF
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
1254046139N Highlight
CHECKED:
DRAWN:
PROJ. NO:
SCALE:
STAMP:
PROJECT TITLE:
DATE:
DRAWING:
SHEET:
FILE NAME:
APPROVED
AIR NATIONAL GUARD
LT. COL. DUSHANE
LT. COL. W.P. KELLY
ANG BASE CIVIL ENGINEER
FUSS & O'NEILL
Disciplines to Deliver
| AXQD152009 - Location of Work |
| Hangar 013 Power Plan |
| Hangar 019 Power Plan |
| Hangar 023 Power Plan |
| Hangar 027 Power Plan |
| Hangar 045 Power Plan |
| Hangar 046 Power Plan |
| Hangar 047 Power Plan |
File details come from the government source that posted it. Updated .