W912QR25BA019_Plans-0000.pdf

PDF 40 MB Posted

Attached to
DBB - Construct Addition and Renovation AGE Facility B820, Minneapolis-St. Paul ARS, MN
Solicitation number
W912QR25BA019
Issued by

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

jo in t v e n t u re

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M

AR

K D

ES

C

R

IP

TI

O

N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

Au to de sk

D oc s:

//M

SP

A

R S

B8

A G

E R en ov at io n/

_0 2-

AR

C

H -M

SP

A

EJ

V

B8

_R

.rv t

7/ 2/

0:

:2

AM

G-001

C O

VE

R

S H

EE

T

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

J

KO

LS

H

O R

N

M H

AY

N

ES

J R

IT

TE

R

S D

U

FF

Y

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

LOUISVILLE DISTRICT

JULY 2025

CERTIFIED FINAL - JULY 2025

PROJECT SITE (B820)

MSP AIR RESERVE STATION

SITE VICINITY MAP

SCALE N/A

MSP

MILITARY HWY

5TH STREETLI

N

D

BE

R G

A

VE

N

SITE VICINITY MAP

SCALE N/A

N

MINNEAPOLIS-ST PAUL AIR RESERVE STATION, MN

CONSTRUCT ADDITION AND RENOVATE AGE

FACILITY, B820

P2: 509918

PROJECT #: QJKL210002

EXP. 1/31/2026

7-02-2025

28 July 2025

W912QR25BA019

W

2Q R

BA

9_

Pl an s-jo in t v e n t u re

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

Au to de sk

D oc s:

//M

SP

A

R S

B8

A G

E R en ov at io n/

_0 2-

AR

C

H -M

SP

A

EJ

V

B8

_R

.rv t

7/ 2/

0:

:0

AM

G-002

SH

EE

T

IN

D

EX

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

J

KO

LS

H

O R

N

M H

AY

N

ES

J R

IT

TE

R

S D

U

FF

Y

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

ARCHITECTURE

A-001 GENERAL NOTES AND ABBREVIATIONS

A-002 AIR BARRIER DIAGRAMS

A-003 AIR BARRIER DIAGRAMS

AD101 DEMOLITION PLAN

AD201 NORTH AND SOUTH DEMOLITION ELEVATIONS

AD202 EAST AND WEST DEMOLITION ELEVATIONS

A-101 FLOOR PLAN

A-102 PARTIAL FLOOR PLAN

A-103 PARTIAL FLOOR PLAN

A-111 ROOF PLAN

A-121 REFLECTED CEILING PLAN

A-122 PARTIAL REFLECTED CEILING PLAN

A-123 PARTIAL REFLECTED CEILING PLAN

A-201 NORTH AND SOUTH ELEVATIONS

A-202 EAST AND WEST ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-310 WALL SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-501 EXTERIOR ASSEMBLIES AND INTERIOR PARTITION DETAILS

A-510 DETAILS

A-511 DETAILS

A-550 OPENING DETAILS

A-601 OPENING SCHEDULE AND SIGNAGE DETAILS

STRUCTURAL

S-001 GENERAL NOTES - STRUCTURAL

S-002 GENERAL NOTES, DESIGN LOADS, AND

ABBREVIATIONS - STRUCTURAL

S-003 SPECIAL INSPECTIONS - STRUCTURAL

S-004 SPECIAL INSPECTIONS - STRUCTURAL

S-101 FOUNDATION PLAN

S-102 WASH BAY CEILING FRAMING PLAN

S-103 ROOF FRAMING PLAN

S-201 FRAMING ELEVATIONS

S-202 FRAMING ELEVATIONS

S-501 TYPICAL DETAILS - STRUCTURAL

S-502 TYPICAL DETAILS - STRUCTURAL

S-510 FOUNDATION DETAILS

S-511 FOUNDATION DETAILS

S-512 MECHANICAL PLATFORM & ROOF FRAMING DETAILS

S-513 ROOF FRAMING DETAILS

S-514 BASE PLATE & PEDESTAL DETAILS

S-515 FRAMING CONNECTION DETAILS

GENERAL

G-001 COVER SHEET

G-002 SHEET INDEX

GI001 CODE REVIEW 1 OF 3 - LIFE SAFETY

GI002 CODE REVIEW 2 OF 3 - LIFE SAFETY

GI003 CODE REVIEW 3 OF 3 - LIFE SAFETY

GI100 SITE PLAN - LIFE SAFETY

GI101 FIRST FLOOR PLAN - NORTH - LIFE SAFETY

GI102 FIRST FLOOR PLAN - SOUTH - LIFE SAFETY

CIVIL

V-101 EXISTING SITE CONDITIONS

B-101 SOIL BORING LOGS

B-102 SOIL BORING LOGS

CD101 SITE DEMOLITION PLAN

C-001 AERIAL LAYOUT PLAN

C-101 SITE LAYOUT PLAN

CS101 SITE LOCATION PLAN

CG101 SITE GRADING PLAN

CG102 SITE DRAINAGE PLAN

CG103 EROSION AND SEDIMENT CONTROL PLAN

CG201 STORM PROFILES

C-501 SITE DETAILS

C-502 SITE DETAILS

C-503 SITE DETAILS

C-504 SITE DETAILS

C-505 SITE DETAILS

C-506 SITE DETAILS

C-507 SITE DETAILS

MECHANICAL

M-001 GENERAL INFORMATION - MECHANICAL

MD101 FIRST FLOOR PLAN - MECHANICAL - DEMOLITION

M-101 FIRST FLOOR PLAN - NORTH - MECHANICAL

M-102 FIRST FLOOR PLAN - SOUTH - MECHANICAL

M-301 SECTIONS - MECHANICAL

M-401 ENLARGED PLANS - MECHANICAL

M-501 DETAILS - MECHANICAL

M-601 SCHEDULES - MECHANICAL

M-601A SCHEDULES (BID OPTION 1) - MECHANICAL

M-701 CONTROLS - MECHANICAL

M-702 CONTROLS - MECHANICAL

M-703 CONTROLS - MECHANICAL

M-704 CONTROLS - MECHANICAL

M-705 CONTROLS - MECHANICAL

M-706 CONTROLS - MECHANICAL

M-707 CONTROLS - MECHANICAL

PLUMBING

P-001 GENERAL INFORMATION - PLUMBING

PD101 FIRST FLOOR PLAN - PLUMBING - DEMOLITION

P-101 FIRST FLOOR PLAN - NORTH - SANITARY

P-102 FIRST FLOOR PLAN - SOUTH - SANITARY

P-111 FIRST FLOOR PLAN - NORTH - DOMESTIC &

NATURAL GAS

P-112 FIRST FLOOR PLAN - SOUTH - DOMESTIC

P-501 DETAILS - PLUMBING

P-601 SCHEDULES - PLUMBING

ELECTRICAL

E-001 GENERAL INFORMATION - ELECTRICAL

ESD101 SITE PLAN - ELECTRICAL - DEMOLITION

ES101 SITE PLAN - ELECTRICAL

ED101 FIRST FLOOR PLAN - ELECTRICAL - DEMOLITION

ED701 DEMOLITION - DIAGRAMS - ELECTRICAL

EL101 FIRST FLOOR PLAN - NORTH - LIGHTING

EL102 FIRST FLOOR PLAN - SOUTH - LIGHTING

EP101 FIRST FLOOR PLAN - NORTH - POWER

EP101A FIRST FLOOR PLAN (BID OPTION 1) - NORTH - POWER

EP102 FIRST FLOOR PLAN - SOUTH - POWER

E-401 ENLARGED PLANS - ELECTRICAL

E-501 DETAILS - ELECTRICAL

E-601 SCHEDULES - ELECTRICAL

E-601A SCHEDULES (BID OPTION 1) - ELECTRICAL

E-700 DIAGRAMS - ELECTRICAL

E-701 DIAGRAMS - ELECTRICAL

E-701A DIAGRAMS (BID OPTION 1) - ELECTRICAL

TECHNOLOGY

T-001 GENERAL INFORMATION - TELECOMMUNICATIONS

TSD101 SITE PLAN - TELECOMMUNICATIONS - DEMOLITION

TS101 SITE PLAN - TELECOMMUNICATIONS

T-101 FIRST FLOOR PLAN - NORTH - TELECOMMUNICATIONS

T-102 FIRST FLOOR PLAN - SOUTH - TELECOMMUNICATIONS

T-401 ENLARGED PLANS - TELECOMMUNICATIONS

T-501 DETAILS - TELECOMMUNICATIONS

FIRE PROTECTION

F-001 GENERAL INFORMATION - FIRE PROTECTION

FD101 FIRST FLOOR PLAN - FIRE PROTECTION - DEMOLITION

FA101 FIRST FLOOR PLAN - NORTH - FIRE ALARM

FA102 FIRST FLOOR PLAN - SOUTH - FIRE ALARM

FA501 DETAILS - FIRE ALARM

FX101 FIRST FLOOR PLAN - NORTH - FIRE SUPPRESSION

FX102 FIRST FLOOR PLAN - SOUTH - FIRE SUPPRESSION

FX501 DETAILS - FIRE SUPPRESSION

7-02-2025

W

2Q R

BA

9_

Pl an s-

Fire Protection / Life Safety / Accessibility Code Review

FORM VERSION 27 DATED 8 OCTOBER 2020

MINNEAPOLIS-ST. PAUL ARMY RESERVE STATION BUILDING 820

1. PROJECT'S APPLIED CODES & STANDARDS

A. UFC 1-200-01: DOD BUILDING CODE, WITH CHANGE 3, 24 FEB 2023

B. UFC 3-600-01: DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE 6, 6 MAY 2021.

C. UFC 4-010-01: DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 3, 24 MAY 2024

D. UFC 4-021-01: DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, WITH CHANGE 1, JANUARY 2010

E. IBC 2021: INTERNATIONAL BUILDING CODE FOR FIRE RESISTANCE REQUIREMENTS, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITS, AND

BUILDING SEPARATION DISTANCE, EXCEPT AS MODIFIED BY UFC 3-600-01

F. NFPA 1, 2024: FIRE CODE, FOR DETERMINING VEHICLE ACCESS REQUIREMENTS

G. NFPA 101, 2024: LIFE SAFETY CODE, FOR BUILDING EGRESS AND LIFE SAFETY EXCEPT AS MODIFIED IN UFC 3-600-01

H. NFPA 10, 2022: STANDARD FOR PORTABLE FIRE EXTINGUISHERS

I. NFPA 13, 2022: STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS, MINIMUM REQUIREMENTS FOR DESIGN AND INSTALLATION OF

AUTOMATIC FIRE SPRINKLER SYSTEMS AND EXPOSURE PROTECTION

J. NFPA 30, 2024: FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, FOR CONSTRUCTION REQUIREMENTS AND FIRE RESISTANCE RATINGS FOR LIQUID

STORAGE AREAS

K. NFPA 30A, 2024: CODE FOR MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES, FOR OCCUPANCY CLASSIFICATION AND MEANS OF

EGRESS FOR REPAIR GARAGES AND ORGANIZATIONAL MAINTENANCE SHOPS

L. NFPA 70, 2023: NATIONAL ELECTRICAL CODE (NEC) - ARTICLE 500 HAZARDOUS LOCATIONS & ARTICLE 511 COMMERCIAL GARAGES, REPAIR &

STORAGE

M. NFPA 80, 2022: STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES

N. NFPA 72, 2022: NATIONAL FIRE ALARM AND SIGNALING CODE

O. NFPA 90A, 2024: STANDARD INSTALLATION OF AIR CONDITIONING & VENTILATION SYSTEMS, FOR PROTECTION OF OPENINGS, SHAFTS, FIRE

DAMPERS, SMOKE DAMPERS, PENETRATIONS AND FAN CONTROL

P. NFPA 291, 2022: RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS

Q. NFPA 400, 2022: HAZARDOUS MATERIAL CODE

R. ABA (ARCHITECTURAL BARRIERS ACT) ACCESSIBILITY STANDARDS, AS DIRECTED BY DOD POLICY MEMO "ACCESS FOR PEOPLE WITH

DISABILITIES" DATED 31 OCT 2008.

S. ECB 2018-17 WITH REV. 3 DATED 31 AUGUST 23: NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS NOTIFICATION SYSTEMS

T. LOUISVILLE DISTRICT MILITARY DESIGN GUIDE (LDMDG)

2. BUILDING CODE REQUIREMENTS:

A. OCCUPANCY CLASSIFICATION:

IBC CHAPTER 3

B. CONSTRUCTION TYPE: TYPE II-B

IBC CHAPTER 6

TABLE 601

C. MIXED USE & OCCUPANCY SEPARATIONS

UFC 3-600-01: 5-4, 5-5

IBC SECTION 508

D. AREA LIMITATIONS / MODIFICATIONS:

UFC 3-600-01: 5-3

IBC SECTION 506

E. HEIGHT LIMITATIONS:

IBC SECTION 503

TABLES 504.3 & 504.4

F. VERTICAL ENCLOSURES, CONTINUITY, PROTECTION: N/A

3-600-01: 3-3.1.1

NFPA 101: 7.1.3, 8.6

NFPA 90A: 4.3.1.2, 5.3.4

G. OPENING PROTECTIVES & THRU-PENETRATIONS

NFPA 101: 8.3 THRU 8.6

NFPA 90A

NFPA 80

NFPA 13

H. HORIZONTAL SEPARATIONS: N/A

IBC: TABLE 508.4

I. FIRE RESISTIVE REQUIREMENTS: INDICATE REQUIREMENTS BASED ON CONSTRUCTION TYPE:

IBC: TABLE 601 AND SECTION 602 PRIMARY STRUCTURAL FRAME - 0 HOUR RATING

EXTERIOR BEARING WALLS - 0 HOUR RATING

INTERIOR BEARING WALLS - 0 HOUR RATING

EXTERIOR NONBEARING PARTITIONS - 0 HOUR RATING

INTERIOR NONBEARING PARTITIONS - 0 HOUR RATING

FLOOR CONSTRUCTION & SECONDARY MEMBERS - 0 HOUR RATING

ROOF CONSTRUCTION & SECONDARY MEMBERS - 0 HOUR RATING

J. ENCLOSURE PROTECTION: N/A

NFPA 101: SPECIFIC OCCUPANCY CHAPTERS

ASME A17.1

UFC 3-600-01; 4-46.5.2.2

K. FIRE PROTECTION SYSTEM: THE ADDITION SHALL BE FULLY PROTECTED BY A WET-PIPE AUTOMATIC SPRINKLER

SYSTEM PER UFC 3-600-01 CHAPTER 9-7.

UFC 3-600-01: CHAPTERS 4 & 9

UFC 3-600-01: APPENDIX B

THE PROJECT WILL HAVE NO FIRE RATED PARTITIONS OR SMOKE RATED

PARTITIONS PROVIDED, SO THERE WILL BE NO REQUIRED OPENING PROTECTION

FOR THIS PROJECT. THE EXISTING BUILDING'S OFFICE AREA HAD DOOR FRAMES THAT

THE ADDITION AND EXISTING BUILDING WILL CONTAIN THE FOLLOWING OCCUPANCIES:

BUSINESS (WITHIN EXISTING BUILDING ONLY) - GROUP B

MODERATE STORAGE - GROUP S-1

MOTOR-VEHICLE-RELATED OCCUPANCY (WITHIN EXISTING BUILDING ONLY):

HEIGHT LIMITATION: (IBC TABLES 504.3 AND 504.4)

PERMITTED – FOR TYPE II-B CONSTRUCTION, IBC TABLE 504.3 LIMITS BUILDING HEIGHT

TO 75 FT FOR GROUPS B AND S OCCUPANCIES. FOR TYPE II-B CONSTRUCTION, IBC

TABLE 504.4 LIMITS BUILDING HEIGHT TO 4 STORIES FOR GROUP B AND S-1

OCCUPANCIES.

PROVIDED – THE BUILDING WITH THE NEW ADDITION IS 1 STORY AND 30’-4-1/2” IN

WITH THE TYPE OF EQUIPMENT TO BE STORED IN THE BUILDING,THE CODE REVIEW

DETERMINED THAT THE MAXIMUM ALLOWABLE QUANTITIES INDICATED IN NFPA 400

WAS NOT EXCEEDED AND THE PROJECT'S SPACE COULD BE CLASSIFIED AS "STORAGE".

BUILDING HEIGHT FOR THE EXISTING STRUCTURE WILL BE AFFECTED BY THE

ADDITION, AS THE ADDITION IS REQUIRED TO HAVE A 25'-0" INSIDE CLEAR SPACE FOR

AREA LIMITATION: (IBC SECTION 506)

PERMITTED – 70,000 SF (FOR S-1 FULLY SPRINKLERED OCCUPANCIES, FRONTAGE

INCREASE NOT NEEDED).

PROVIDED – 15,697 SF

THE BUILDING WILL BE A NON-SEPARATED MIXED USE OCCUPANCY CONSISTING

OF THE OCCUPANCIES INDICATED ABOVE. THE MOST RESTRICTIVE OCCUPANCY FOR

HEIGHT LIMITATION AND AREA LIMITATION (WHICH IS THE S-1 OCCUPANCY) WILL

BE UTILIZED FOR THIS BUILDING.

UFC 3-600-01; 9-7, EXCEPT AS MODIFIED IN CHAPTER 4 OF

UFC FOR SPECIFIC FACILITY TYPES

UFC 3-600-01; 1-12.12, 9-7.3.1.2, 4-46

N/A

NFPA 13

UFC 3-600-01: CHAPTER 9-7.4 COVERAGE PER SPRINKLER MUST BE IN ACCORDANCE WITH NFPA 13, NOT EXCEEDING

130 SF FOR THE ENTIRE AREA OF THE ADDITION. EXTENDED COVERAGE HEADS ARE

NFPA 13

THE JACK TEST STAND. THE MAXIMUM HEIGHT FOR THE ADDITION IS 30'-4-1/2".

THE ADDITION HAS AN APPROXIMATE FLOOR AREA OF 8,278 SF, PROVIDING A TOTAL

BUILDING FLOOR AREA OF 15,697 SF.

HEIGHT.

L. AVAILABLE WATER SUPPLY TESTING A FIRE FLOW TEST WAS CONDUCTED ON 15 OCTOBER 2024 AT AROUND 0800 CDT. THE

FLOW TEST RESULTED IN A STATIC PRESSURE OF 86 PSIG WITH 1,138 GPM AVAILABLE

AT A RESIDUAL PRESSURE OF 70 PSIG. PRELIMINARY HYDRAULIC CALCULATIONS

INDICATE THAT THE CURRENT WATER SUPPLY IS ADEQUATE TO SUPPORT THE FIRE

SPRINKLER SYSTEM. A FIRE PUMP WILL NOT BE REQUIRED FOR THIS PROJECT.

WATER SUPPLY MEETS FIRE FLOW REQUIREMENTS (1,000 GPM AT 20 PSI REQUIRED,

2,446 GPM AVAILABLE AT 20 PSI) OF UFC 3-600-01 SECTION 9-2.1.

UFC 3-600-01: 1-12.5, 9-6.4

NFPA 291

UFC 3-600-01: 9-2.2 N/A

NFPA 1: TABLE 18.4.5.2.1

UFC 3-600-01: 1-12.10, 4-40 N/A

M. WATER STORAGE TANK REQUIREMENTS N/A

UFC 3-600-01: 1-12.4, CHAPTER 9-4

NFPA 22

N. BACKFLOW PREVENTER & TESTING MINIMUM PRESSURE DROP ACROSS BACKFLOW PREVENTER IS 8 PSI FOR HYDRAULIC

CALCULATIONS.

NFPA 13: 8.16.4.6.1

UFC 3-600-01; 9-6.3.5, 9-6.6

O. FIRE PUMP(S) N/A

UFC 3-600-01: CHAPTER 9-5

NFPA 20

UFC 3-600-01: 9-5.1.4

NOT PERMITTED. SPRINKLER HEADS WILL BE PROVIDED WITH A K-FACTOR OF 11.2 FOR.

THE MAIN AREA AND 8.0 FOR THE CONNECTOR AND THE ELECTRICAL ROOM.

REPAIR GARAGES - GROUP S-1 (406.8)

WERE RATED FOR 1-1/2 HOURS, BUT IT COULD NOT BE DETERMINED IF THE ACTUAL

WALLS WERE FIRE RATED. ALSO, DOORS DID NOT APPEAR TO BE RATED, AND SOME

SPACES DID NOT EVEN HAVE DOORS INSTALLED IN THESE RATED FRAMES. WITH THIS

CODE REVIEW, THE RATED WALLS ARE NOT REQUIRED FOR THESE SPACES, AND NO

WORK WILL BE PERFORMED ON THESE WALLS. ALL EXISTING PENETRATIONS REUSED

FOR NEW WORK WILL BE SEALED TO MATCH EXISTING CONDITIONS.

UTILIZING STORAGE FOR THE BUILDING AND CLASS IV COMMODITIES, THE SPACE WILL

BE SET UP TO BE HYDRAULICALLY CALCULATED WITH THE WORST-CASE CONDITION

FOR THE STORAGE AREAS PER NFPA 13 CHAPTERS 4 AND 21, AS WELL AS UFC 3-600-01.

FOR THE HIGH-BAY AREA, THE ONLY REASON IT IS TO THE SCALE PROVIDED IS FOR A

SPECIFIC PIECE OF EQUIPMENT, ITS STORAGE CONDITIONS WOULD BE, AT WORST-

CASE, SIMILAR TO THE LOW-BAY AREA, SO WE WILL USE THE SAME DESIGN CRITERIA

FOR THE ENTIRE STORAGE AREA FOR CONSISTENCY (18 FT. HIGH STORAGE FOR THE

29 FT. HIGH PEAK HEIGHT SPACE).

FOR THE MAIN STORAGE AREA, SYSTEM WILL BE PROVIDED PER TABLE 21.2.2.2.1 WITH

CONTROL MODE DENSITY AREA (CDMA) SPRINKLERS WITH HIGH-TEMPERATURE-RATED

HEAD FOR A STORAGE HEIGHT UP TO 18 FT.:

0.27-GPM/SF OVER THE MOST REMOTE 2,000 SF PER THE TABLE

FOR THE CONNECTOR AREA, BEING THAT THE SPACE HEIGHT IS LESS THAN 12 FT.,

THIS SPACE WILL BE PROTECTED PER TABLE 4.3.1.7.1.1 AS SOLID-PILED STORAGE FOR

STORAGE HEIGHTS UP TO 12 FT.. THAT HAS A REQUIREMENT OF ORDINARY HAZARD

PROTECTION FOR THE AREA.

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:2

P M

GI001

C O

D E

R E

V

IE

W

O F

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

8 W

2Q

R

BA

9_ Pl an s-

3. LIFE SAFETY REQUIREMENTS:

A. CLASSIFICATION OF OCCUPANCY: THE ADDITION AND EXISTING BUILDING WILL CONTAIN MIXED OCCUPANCIES

(NON-SEPARATED) CONSISTING OF THE FOLLOWING OCCUPANCIES:

BUSINESS

(WITHIN EXISTING BUILDING ONLY)

STORAGE

INDUSTRIAL (REPAIR GARAGE, WITHIN

EXISTING BUILDING ONLY)

NFPA 101: CH. 6

B. OCCUPANT LOAD:

NFPA 101: 7.3.1.2 & CHAPTERS 12-42

UFC 3-600-01: 10-3.1

C. CAPACITY OF MEANS OF EGRESS:

NFPA 101: 7.3.3 & CHAPTERS 12-42

D. NUMBER OF EXITS: MINIMUM OF 2 EXITS REQUIRED FOR THE EXISTING BUILDING. 11 EXITS PROVIDED.

SINGLE MEANS OF EGRESS IS PERMITTED IN STORAGE OCCUPANCIES WHEN EXIT CAN

BE REACHED WITHIN 100 FEET (COMMON PATH OF TRAVEL).

NFPA 101: 7.4 & CHAPTERS 12-42

E. ARRANGEMENT OF MEANS OF EGRESS MEANS OF EGRESS WILL COMPLY WITH NFPA 101. BUILDING WILL BE PROTECTED WITH

AUTOMATIC FIRE SPRINKLERS THROUGHOUT.

NFPA 101: 7.5 & CHAPTERS 12-42

F. ACCESSIBLE MEANS OF EGRESS NOT LESS THAN 2 ACCESSIBLE MEANS OF EGRESS REQUIRED. 2 ACCESSIBLE MEANS

OF EGRESS PROVIDED.

NFPA 101: 7.5.4

G. TRAVEL DISTANCE TO EXITS:

NFPA 101: 7.6 & CHAPTERS 12-42

H. ILLUMINATION OF MEANS OF EGRESS: ALL EXITS SHALL BE PROVIDED WITH EMERGENCY ILLUMINATION. ILLUMINATION OF

MEANS OF EGRESS SHALL BE PROVIDED AT ALL TIMES DURING OCCUPANCY.

NFPA 101: 7.8 & CHAPTERS 12-42

I. EMERGENCY LIGHTING:

NFPA 101: 7.9 & CHAPTERS 12-42

J. MARKING OF MEANS OF EGRESS:

NFPA 101: 7.10 & CHAPTERS 12-42

K. INTERIOR FINISH CLASSIFICATION LIMITS:

NFPA 101: TABLE A.10.2.2

L. DETECTION, ALARM, & COMMUNICATIONS: THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS), BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A

FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE

DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO

REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE

BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE

NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY

REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET

AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN

EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING

IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES

SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.

ALSO, WITHIN THE EXISTING SPRINKLER RISER ROOM, A NEW LOW-TEMPERATURE

DEVICE WILL BE PROVIDED IN THE SPACE TO ALERT THE FIRE ALARM REPORTING

STATION THAT AN ISSUE IS OCCURRING IF THE TEMPERATURE DROPS BELOW THE

DEVICE'S SET-POINT.

CO DETECTORS WILL BE PROVIDED WITHIN THE EXISTING BUILDING AND THE

ADDITION PER UFC 3-600-01.

UFC 3-600-01: CHAPTER 9-18

NFPA 101: 9.6 & CHAPTERS 12-42

M. PORTABLE FIRE EXTINGUISHERS: PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WITHIN THE ADDITION WHERE

REQUIRED PER NFPA 101. FIRE EXTINGUISHERS SHALL BE SIZED AND LOCATED IN

ACCORDANCE WITH NFPA 10.UFC 3-600-01, 9-17

NFPA 10

N. CORRIDORS: NO RATINGS REQUIRED.

NFPA 101: CHAPTERS 12-42

O. FIRE DAMPERS: N/A, AS THERE ARE NO FIRE RATED CONSTRUCTION TO BE PROVIDED FOR THIS

BUILDING.

NFPA 90A: 5.3.1, 5.4.1 & 5.4.2

P. SMOKE DAMPERS: N/A, AS THERE ARE NO SMOKE RATED CONSTRUCTION TO BE PROVIDED FOR THIS

BUILDING.

IBC: SECTION 716

NFPA 90A: 4.3.10.2, 5.3.5.1

Q. DUCT SMOKE DETECTORS

NFPA 90A: 6.4.2.1

R. ELEVATORS N/A

UFC 3-600-01: 4-13

IBC CHAPTER 30

ASME A17.1

NFPA 13

UFC 3-490-06: 3-3.1

S. ROOF ACCESS: N/A

UFC 3-600-01: 10-4

IBC CHAPTER 1011.12

T. HAZARDOUS LOCATIONS IN COMMERCIAL GARAGES N/A

NFPA 70: NEC ARTICLES 500 & 511

U. FIRE DEPT. VEHICLE ACCESS FIRE DEPARTMENT VEHICLES MUST HAVE UNIMPEDED ACCESS TO THE BUILDING

FROM AT LEAST ONE DIRECTION FOR EMERGENCY VEHICLE ACCESS. ACCESS SHALL

TERMINATE NO FURTHER THAN 33 FEET FROM THE BUILDING. PAVED AREAS PROVIDE

ACCESS TO ALL TWO SIDES OF THE BUILDING.

UFC 3-600-01: 9-1

NFPA 1: 18.2.3.4.1

V. FIRE HYDRANT INSTALLATION THE FDC MUST BE LOCATED WITHIN 150’ OF A FIRE HYDRANT PER UFC 3-600-01.

EXISTING FDC MEETS THIS REQUIREMENT.

UFC 3-600-01: 9-3.5

W. KITCHEN COOKING EXHAUST EQUIPMENT N/A

NFPA 101: 9.2.3, CHAPTERS 12-42

NFPA 96

OCCUPANT LOAD CALCULATION BELOW INCLUDES BOTH THE ADDITION AND THE

EXISTING BUILDING. OCCUPANT LOAD FACTORS ARE IN ACCORDANCE WITH NFPA 101

EXCEPT AS MODIFIED BY UFC 3-600-01.

MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES:

517 SF / 500 SF OCCUPANT = 1.03 OCCUPANTS

BUSINESS: 889 SF / 150 SF / OCCUPANT = 5.93 OCCUPANTS

STORAGE (INCLUDING JACK TEST STAND AND TOOL CRIB):

INDUSTRIAL(MAINTENANCE AREA, WASH BAY, PARTS CLEANING, BATTERY

2,787 SF / 100 SF / OCCUPANT = 27.87 OCCUPANTS

CALCULATED OCCUPANT LOAD: 58 OCCUPANTS.

NFPA 101 EXIT CAPACITIES (ADDITION AND EXISTING BUILDING)

EXIT DOOR = 34" OPENING (36" DOOR) / 0.2 IN/OCCUPANT = 170 OCCUPANTS

11 EXIT DOORS FOR ADDITION AND EXISTING BUILDING (NOT COUNTING MECHANICAL

OR ELECTRICAL ROOM)

BUILDING EXIT CAPACITY = 1,870 OCCUPANTS

EMERGENCY EGRESS LIGHTING WILL BE PROVIDED IN ACCORDANCE WITH NFPA 101

§7.9. THE EMERGENCY LIGHTING WILL BE PROVIDED FOR 1 ½ HOURS UPON THE

FAILURE OF NORMAL LIGHTING. INITIAL LIGHTING LEVELS WILL BE NOT LESS THAN AN

AVERAGE OF 1 FT-CANDLE AND NOT LESS THAN 0.1 FT-CANDLE ALONG THE PATH OF

EGRESS (AT FLOOR LEVEL). THESE LEVELS ARE PERMITTED TO DECLINE TO NOT LESS

THAN AN AVERAGE OF 0.6 FT-CANDLE AND NOT LESS THAN 0.06 FT-CANDLE ALONG THE

PATH OF EGRESS (AT FLOOR LEVEL) UNTIL 1 ½ HOURS HAVE PASSED.

THE EMERGENCY LIGHTING SYSTEM WILL BE AT LEAST TYPE 10, CLASS 1.5, LEVEL 1 IN

ACCORDANCE WITH NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER

SYSTEMS.

EMERGENCY LIGHTING WILL BE SHOWN ON ELECTRICAL PLANS FOR CLARITY AND

CIRCUITING. LIFE SAFETY PLANS WILL REFERENCE ELECTRICAL PLANS FOR

EMERGENCY LIGHTING.

THE MEANS OF EGRESS WILL BE MARKED IN ACCORDANCE WITH NFPA 101 §7.10 AND

UFC 3-600-01 §10-2. EACH EXIT DOOR WILL BE MARKED BY AN EXIT SIGN VISIBLE FROM

ANY DIRECTION OF EXIT ACCESS. ADDITIONAL EXIT SIGNS WILL BE PROVIDED ALONG

EXIT ACCESS PATHS WHERE THE PATH IS NOT OBVIOUS.

EXIT SIGNS WILL BE LIGHT EMITTING DIODE (LED), ELECTROLUMINESCENCE (LEC) OR

COLD CATHODE TYPE. INCANDESCENT TYPE EXIT SIGNS WILL NOT BE USED.

EXIT SIGNS WILL BE SHOWN ON THE ELECTRICAL PLANS (FOR CIRCUITING) AND THE

LIFE SAFETY PLANS.

TACTILE SIGNAGE READING “EXIT” WILL BE PROVIDED AT EACH EXIT DOOR. THESE

SIGNS SHALL COMPLY WITH ICC / ANSI A117.1, AMERICAN NATIONAL STANDARD FOR

ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES.

TACTILE SIGNS WILL BE SHOWN ON THE INTERIOR DESIGN SIGNAGE PLANS.

CLASS A, B, OR C FOR RATED CORRIDORS.

CLASS A, B, OR C FOR OTHER AREAS.

FLOOR FINISH TYPE 1 OR 2.

SMOKE DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE

LOCATED AS FOLLOWS:

DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN AIR

SUPPLY STEMS HAVING A CAPACITY GREATER THAN 2000 CFM.

11,504 SF / 500 SF / OCCUPANT = 23.01 OCCUPANTS

MEASURE - BUSINESS:

MAXIMUM TRAVEL DISTANCE = 300'

MAXIMUM COMMON PATH OF TRAVEL = 100'

MAXIMUM DEAD END = 50'

MEASURE - INDUSTRIAL (GENERAL PURPOSE):

MAXIMUM TRAVEL DISTANCE = 250'

MAXIMUM COMMON PATH OF TRAVEL = 100'

MAXIMUM DEAD END = 50'

MEASURE - STORAGE OCCUPANCY:

MAXIMUM TRAVEL DISTANCE = 400'

MAXIMUM COMMON PATH OF TRAVEL = 100'

MAXIMUM DEAD END = 50'

MEASURE - MECHANICAL PLATFORM (MECHANICAL ROOM PER SECTION 7.13):

MAXIMUM TRAVEL DISTANCE = 50'

(REFER TO SHEET GI103 FOR TABULATED OCCUPANT COUNT

PER SPACE/AREA)

ROOM, AND RESTROOMS):

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:2

P M

GI002

C O

D E

R E

V

IE

W

O F

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

8 W

2Q

R

BA

9_ Pl an s-

OCCUPANT COUNT

SPACE

BUSINESS GROUP

OFFICE AREA (X-110, X-112, X-113)

NUMBER OF OCCUPANTS

150 SF / OCCUPANT

5.74

MECHANICAL/ELECTRICAL

- X-112 IS UTILIZED AS OPEN OFFICE

COMM/ELECTRICAL (X-115, X-109)

MECHANICAL/SPRINKLER (X-107, X-108)

SQUARE FOOTAGE

500 SF / OCCUPANT

0.33

0.36

STORAGE AREA

TOOL CRIB (X-111)

MATERIAL STORAGE (X-117)

500 SF / OCCUPANT

0.43

0.54

INDUSTRIAL AREA

BATTERY ROOM (X-116)

RESTROOMS (ADJACENT TO THIS AREA) (X-105, X-106)

100 SF / OCCUPANT

0.70

6.13

TOTAL CALCULATED OCCUPANT LOAD = 57 OCCUPANTS

ELECTRICAL (102) 0.31157

OPEN STORAGE (MINUS REPAIR AREA) (X-104, 100) 21.3510,674

WASH BAY (101) 7.76776

REPAIR AREA OF OPEN STORAGE (X-104) 11.471,147

PARTS CLEANING (X-114) 0.9797

4. EXISTING FACILITIES:

A. EXISTING FACILITY DEFICIENCY UPGRADE: FACILITIES AS THEY EXIST PRIOR TO PROJECT, MUST MEET NFPA 101 FOR EXISTING

OCCUPANCY. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EVERY

EXISTING BUSINESS OCCUPANCY PER NFPA 101. ADDITIONAL FIRE EXTINGUISHERS

WILL BE PROVIDED IN THE EXISTING BUILDING TO SATISFY THIS REQUIREMENT.

UFC 3-600-01: 34-1.1

NFPA 101: CHAPTERS 12-42

B. WORK IN EXISTING FACILITIES:

UFC 3-600-01: 34-1.2.1

NFPA 101, CHAPTER 43, REPAIR N/A

NFPA 101, CHAPTER 43, RENOVATION THE EXISTING FIRE ALARM AND MASS NOTIFICATION SYSTEM WILL BE COMPLETELY

REMOVED FROM THE EXISTING BUILDING AND A NEW SYSTEM WILL BE INSTALLED,

COMPLYING TO THE REQUIREMENTS OF UFC 3-600-01 AND NFPA 72. THE BUILDING'S

OFFICE AREA WILL ALSO MEET THE INTELLIGIBILITY REQUIREMENTS FOR A MASS

NOTIFICATION SYSTEM PER UFC 4-021-01.

NFPA 101, CHAPTER 43, MODIFICATION THE EXISTING BUILDING WILL HAVE AN EXISTING ADDITION TO THE MAIN BUILDING

REMOVED, AS WELL AS THE REMOVAL OF A SEGMENT OF THE NE EXTERIOR WALL AND

A SECTION OF INTERIOR WALL ABOUT 20 FT LONG WITHIN THE EXISTING

SHOP/STORAGE AREA. NONE OF THESE MODIFICATION WILL AFFECT THE REMAINING

EXISTING BUILDING FLOOR AREA.

NFPA 101, CHAPTER 43, RECONSTRUCTION N/A

UFC 3-600-01: 34-1.2.8 THE AREA OF THE MODIFICATION WITHIN THE EXISTING REMAINING BUILDING IS

NEGLIBILE IN AREA.

UFC 3-600-01:34-1.2.9 N/A

NFPA 101, CHAPTER 43, ADDITION THE ADDITION SHALL BE SPRINKLERED THROUGHOUT AS REQUIRED BY UFC 3-600-01

SECTION 9-7.2.4. THE FIRE ALARM SYSTEM WILL ALSO BE EXTENDED TO COVER THE

ENTIRE ADDITION.

C. CHANGE IN USE CATEGORY: N/A

UFC 3-600-01:34-1.3

D. VACANT BLDG. CATEGORY: N/A

UFC 3-600-01:34-1.4

E. PHASED PROJECTS: N/A

UFC 3-600-01:34-2

F. COOKING AREAS: N/A

UFC 3-600-01:34-3

G. ELECTRONIC EQUIPMENT AREAS: N/A

UFC 3-600-01:34-5

H. AUTOMATIC SPRINKLER SYSTEMS: EXISTING BUILDING AND ADDITION SHALL BE SPRINKLERED THROUGHOUT PER UFC

3-600-01 SECTIONS 9-7.2.4 AND 9-7.2.1.1.

UFC 3-600-01: 34-1.2.6 & 9-7.2

I. FIRE ALARM SYSTEM:

THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS),

BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A

FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE

DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO

REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE

BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE

NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY

REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET

AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN

EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING

IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES

SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.

ALSO, WITHIN THE EXISTING SPRINKLER RISER ROOM, A NEW LOW-TEMPERATURE

DEVICE WILL BE PROVIDED IN THE SPACE TO ALERT THE FIRE ALARM REPORTING

STATION THAT AN ISSUE IS OCCURRING IF THE TEMPERATURE DROPS BELOW THE

DEVICE'S SET-POINT.

CO DETECTORS WILL BE PROVIDED WITHIN THE EXISTING BUILDING AND THE

ADDITION PER UFC 3-600-01.

UFC 3-600-01:34-1.2.8 & 9-18

5. MASS NOTIFICATION:

UFC 4-021-01 THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS), BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A

FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE

DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO

REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE

BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE

NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY

REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET

AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN

EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING

IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES

SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.

ECB 2018-17

6. ACCESSIBILITY REQUIREMENTS:

ABA CHAPTERS 1-10 THE FIRE ALARM MASS NOTIFICATION SYSTEM SHALL HAVE PERMANENTLY INSTALLED

AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72, EXCEPT THAT THE

MAXIMUM ALLOWABLE SOUND LEVEL OF AUDIBLE NOTIFICATION APPLIANCES SHALL

NOT HAVE A SOUND LEVEL EXCEEDING 110 DB AT THE MINIMUM HEARING DISTANCE

FROM THE AUDIBLE APPLIANCE.

LIFE SAFETY SYMBOLS

ACTUAL EGRESS CAPACITY

NOTE: NOT ALL SYMBOLS MAY BE USED

DESCRIPTIONSYMBOL COMMENTS

EGRESS CAPACITY

THROUGH DOORWAY

TRAVEL DISTANCE

EGRESS DOORS @ WIDTH (IN.)

EGRESS CAPACITY (OCCUPANTS)

X @ XX

XXX

XX = XX'-X" TD = TRAVEL DISTANCE

CT = COMMON PATH OF TRAVEL

DE = DEAD END

XX

PORTABLE FIRE

EXTINGUISHER

BASIC SHAPE, SEE

DRAWINGS FOR TYPE

REQUIREMENTS

END OF COMMON PATH

EXIT SIGN - SHADING

INDICATES FACE, ARROW

INDICATES DIRECTION

XXX'-X' HOSE PATH AND LENGTH

FROM HYDRANT TO END OF

LINE

LIFE SAFETY SYMBOLS

WALL - BASIC SHAPE

NOTE: NOT ALL SYMBOLS MAY BE USED

SSMOKE-RATED WALL

1/2-HOUR FIRE-RATED WALL

1/2-HOUR FIRE / SMOKE-RATED WALL S

3/4-HOUR FIRE-RATED WALL

3/4-HOUR FIRE / SMOKE-RATED WALL S

1-HOUR FIRE-RATED WALL

1-HOUR FIRE / SMOKE-RATED WALL S

2-HOUR FIRE-RATED WALL

2-HOUR FIRE WALL

F

2-HOUR FIRE / SMOKE-RATED WALL S

3-HOUR FIRE-RATED WALL

3-HOUR FIRE WALL

F

3-HOUR FIRE / SMOKE-RATED WALL S

4-HOUR FIRE-RATED WALL

4-HOUR FIRE WALL

F

4-HOUR FIRE / SMOKE-RATED WALL S

FIRE EXTINGUISHER REQUIREMENTS

UNIT SIZE

(POUNDS)

RATING COVERAGE AREA BASED ON

OCCUPANT HAZARD

NUMBER OF UNITS

REQUIRED

NUMBER OF UNITS

PROVIDED

MAXIMUM TRAVEL

DISTANCE

75 FEET753,000 ORDINARY

6,000 LIGHT

2A:10B:C5

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:3

P M

GI003

C O

D E

R E

V

IE

W

O F

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

8 W

2Q

R

BA

9_ Pl an s-

S

SS

E

E

E

E

E

G

G

C

C

FFE

FFE

FFE

834.50

834.30

834.48

U

U

D

D

D

C I

CB

CB

C I C

I

CB

MAGNAIL

MAGNAIL

MAGNAIL

IPIN

IPIN

CO

PIV

HYDRANT 46

HYDRANT 51

215'-7"

307'-7"

145'-2"

161'-2"

199'-0"

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:3

P M

GI100

S

IT

E P

L A

N

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

GENERAL SHEET NOTES

1. REFER TO DRAWING GI003 FOR SYMBOLS.

2. THERE IS NO WATER STORAGE TANK, HAZARDEOUS MATERIAL

SPILL CONTAINMENT TANKS, OR FIRE PUMP TO BE PROVIDED

FOR THIS PROJECT.

3. EXISTING BACKFLOW PREVENTER ASSEMBLY IS LOCATED

WITHIN THE BUILDING.

SHEET KEYNOTES

1. HYDRANT 58, UTILIZED AS THE FLOW HYRANT FOR THE FLOW

TEST, IS LOCATED FURTHER SOUTH ON THE SITE. THE

HYDRANT IS LOCATED APPROXIMATELY 192' FROM

SOUTHWESTERN CORNER OF THE EXISTING BUILDING.

2. HYDRANT 66, UTILIZED AS THE GAUGE (PRESSURE) HYDRANT

FOR THE FLOW TEST.

3. 6" WATER SERVICE FOR THE BUILDING.

4. FIRE TRUCK ACCESS VIA THE AIRFIELD.

5. FIRE DEPARTMENT ACCESS INTO THE BUILDING.

6. EXISTING SITE FENCE WITH SECURITY CONTROLLED GATE

ACROSS DOOLITTLE AVENUE.

7. SITE FENCE FROM BUILDING 820 AND ACROSS APOLLO

AVENUE.

8. EXISTING FIRE DEPARTMENT CONNECTION ON BUILDING,

HOSE LENGTH TO HYDRANT IS 136'-6".

9. LOCATION OF EXISTING POST INDICATOR VALVE.

NORTH

SCALE: 1" = 20'-0"

A2

SITE PLAN - LIFE SAFETY

0 10' 20' 40'

W

2Q R

BA

9_

Pl an s-

1 @ 34

1 @ 34

1 @ 34

TD = 87'-4"

T D

2 @ 68

LOW BAY

STORAGE

ELEC

WASH BAY

2.1 3 4 5

AA

BB

5.9 6.9

FF

EE

DD

CC

TD = 94'-8"

MULE

MAINTENANCE

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEY PLAN

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:3

P M

GI101

F

IR

S T

F L O

O R

P L A

N

N O

R T

H

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

GENERAL SHEET NOTES

1. REFER TO DRAWING GI003 FOR SYMBOLS.

SHEET KEYNOTES

1. TOP OF WASH BAY IS 16'-0" ABOVE FINISHED FLOOR AND IS A

MECHANICAL PLATFORM. MEANS OF EGRESS PATH IS FROM

ACCESS SIDE OF MAU-03, REFER TO SHEET M-101 FOR

ADDITIONAL INFORMATION. TRAVEL DISTANCE INCLUDES A

VERTICAL TRAVEL DISTANCE OF 13'-6" PLUS HORIZONTAL

TRAVEL DISTANCE SHOWN.

2. SHIPS LADDER FOR ACCESS TO MECHANICAL PLATFORM,

REFER TO ARCHITECTURAL SHEETS FOR MORE INFORMATION.

3. FOR EXIT POINT OF TRAVEL DISTANCE LINE, REFER TO FIRST

FLOOR PLAN - SOUTH - LIKE SAFETY PLAN ON SHEET GI102.

4. FIRE EXTINGUISHER LOCATED ON MECHANICAL PLATFORM

ABOVE WASH BAY.

NORTH

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR PLAN - NORTH - LIFE SAFETY

W

2Q R

BA

9_

Pl an s-

1 @ 34

1 @ 34

0 1

1 @ 34

T D

TD = 124'-2"

15 16

CLASSROOM

COMPUTER

X-112

OFFICE

X-113

BATTERY

X-116

HALL

X-110

PARTS CLEANING

X-114

COMM

X-115

ELEC

X-109

EXISTING

STORAGE

X-104

WOMENS

X-106

MENS

X-105

MECHANICAL

X-107

SPRINKLER

X-108

MATERIAL

STORAGE

X-117

2.1 3 4 5 62

AA

A

B

TOOL CRIB

X-111

BOWMAN

E-81028

JOHN

PHILIP

O

H

I

OFO

S

TA

ET

E R

E I

E

E

R E

N

G

ND

P R

SI

G

S F

E

S

E

O

R

T

I O N A L j o i n t v e n t u r e

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

KEY PLAN

07/01/2025

A u to d e s k D o c s

/M S

P A

R S

B A

G E

R e n o v a ti o n /M

S P

A E

J V

B v

M E

P F

T .r v t

/1

/2

:4

:4

P M

GI102

F

IR

S T

F L O

O R

P L A

N

S O

U T

H

L

IF

E S

A F

E T

Y

M

IN

N E

A P

O L

IS

-S T

P A

U L A

IR

R

E S

E R

V E

S T

A T

IO

N

M

N L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P .O

B

O X

L

O U

IS

V

IL

L E

K

Y

-0

P B

O W

M A

N

P B

O W

M A

N

J R

IT

T

E R

J L E

E

M A

Y

C E

R T

IF

IE

D F

IN

A

L

J U

L Y

C O

N S

T R

U C

T A

D D

IT

IO

N A

N D

R E

N O

V A

T E

A G

E F

A C

IL

IT

Y

B

P

GENERAL SHEET NOTES

1. REFER TO DRAWING GI003 FOR SYMBOLS.

SHEET KEYNOTES

1. FOR STARTING POINT OF TRAVEL DISTANCE LINE, REFER TO

FIRST FLOOR PLAN - NORTH - LIKE SAFETY PLAN ON SHEET

GI101.

2. FIRE EXTINGUISHER LOCATED ON EXISTING MEZANNINE.

NORTH

0 4' 8' 16'

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR PLAN - SOUTH - LIFE SAFETY

W

2Q R

BA

9_

Pl an s-

C I

G

CB

CO

C I D C

I

E

D

S U

U

E

IPIN

IPIN

MAGNAIL

MAGNAIL

MAGNAIL

FFE834.50

E

FFE834.30

S

E

G

FFE834.48

E

CB

CB

D

CB

D

G G

G

G G

G G

G G

G

W W W

W W

W W

W W

W W

W W

W

E

E

G G G

W W W W W W W W W W W W W W W W W W W W W W

G G G

G

G

G

X X X X X

X

X X X X X

SD SD SD SD SD SD

SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SAN

SAN

SAN SAN SAN SAN SAN

SA

N SAN

SAN

SAN

SAN

SAN

SANW

W

W W

W W W W W W W

W W W W W

W W W

W W

W W

W W

W W

WW

ES

ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES

E E E E E E E E E E E E E E E E E E E

E

E

E

E

E

E

E

E E

E E

W

ES ES ES ES ES ES ES ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES ES ES ES ES ES ES

FO

FO

FO FO

FO

E E

E E

E E

E E

E E

E E

E E E E E E E

FO

FO

FO

E E

E

C

C

S

SAN

SAN MH RIM 833.26

8" PVC 826.11(W)

8" PVC 826.16 (S)

6" PVC 826.86 (NE)

3" PVC 827.06 (E)

SAN MH RIM 833.85

8" PVC 827.65 (W)

8" PVC 827.65 (E)

4" PVC 827.60 (N)

SAN

SAN MH RIM 832.78

8" PVC 823.28 (E)

8" PVC 822.68 (N)

8" PVC 822.58 (S)

STM MH RIM 832.81

12" VCP 823.31 (N)

12" VCP 826.31 (W)

18" VCP 823.31 (S)

STM MH RIM 832.71

12" PVC 826.21 (NE)

12" RCP 824.31 (W)STM MH RIM 832.81

12" RCP 824.61 (E)

12" RCP 824.31 (S)

12" RCP 824.31 (W)

10" RCP 825.9 (NW)

12" RCP 828.21 (NW)

6" VCP 826.21 (NW)

SD SD

STM CB TOP 832.16

12" PVC 826.51 (W)

12" PVC 826.48 (N)

STM CB TOP 831.85

12" PVC 826.75 (S)

12" PVC 827.05 (N)

EMH TOP 833.39

BOT. 830.4

TOP COND. 832.2

ES

COMM MH 833.39

BOT. 825.8

BOT. T/SLAB (10") 831.1

COM MH 833.08

BOT. 826.23

BOT. T/SLAB (10") 831.1

SIXTH STREET

AP

O

LL

O

A

VE

N U

E

D O

O

LI

TT

LE

A

VE

N U

E

BUILDING 820

FFE 834.50

STM CB TOP 832.53

12" PVC 823.73 (N)

12" RCP 828.13 (W)

12" PVC 823.63 (S)

6" PVC 826.9 (S)

4" PVC 831.5 (SE)

ASPHALT DR.

CONC. DR.CONC. DR.

IPIN

N: 1019851.65 E: 2828626.33

Z: 833.17

IPIN

N: 1019798.72 E: 2828885.03 Z: 832.86

MAG NAIL

N: 1019628.39 E: 2828644.73

Z: 832.46

ASPHALT DR.

CONC.

DUMPSTER

PAD

GRASS

BLDG. 814

GRASS

CONC. WALK

GRASS

GRASS

GRASS

AS

PH

AL

T

D R

ASPHALT DRIVE

CONCRETE AIRFIELD RAMP

MAG NAIL

N: 1019655.87 E: 2828856.81

Z: 832.33BLDG. 822

BLDG. 807

CURB &

GUTTER

C U

R B

G

U

TT

ER

CURB &

GUTTER

CURB &

GUTTER

(ABAN.) STEAM MH 832.88

BOT. 826.7

BOT. T/SLAB (7") 831.4

PIV

E

EX RAMP LIGHT POLE

EX RAMP LIGHT POLE

AVIONICS B805

EXISTING

PARKING

LOT

BURIED

STRUCTURE

TO REMAIN

X

4 83

W W

EMH TOP 833.37

BOT. 828.0

BOT. T/SLAB (6") 832.3

SOIL - B-01 SOIL - B-02

SOIL - B-03

SOIL - B-04

SOIL - B-07SOIL - B-05

EXISTING LEGEND

AC UNIT

BUSH

SQUARE CATCH BASIN

CLEAN OUT

COMMUNICATION MANHOLE

GUY WIRE

DRAIN

ELECTRIC BOX

ELECTRIC METER

ELECTRIC MANHOLE

ELECTRIC/POWER POLE

FIRE HYDRANT

FINISH FLOOR ELEVATION

GAS METER

GAS VALVE

IRON PIN CONTROL POINT

LIGHT POLE

MONITORING WELL

PAYPHONE

PARKING MARKING - ACCESSIBLE

POST

SANITARY MANHOLE

SIGN

STORM MANHOLE

TREE

UTILITY MANHOLE

UTILITY VALVE

WATER VALVE

CB

CO

C

E

E

FFE

G

G

IPIN

MW

S

D

U

U

FIRE DEPARTMENT CONNECTIONFDC

ASPHALT

PIV

FDC

POST INDICATOR VALVE

FIRE DEPARTMENT CONNECTION

EXISTING MAJOR CONTOUR

EXISTING MINOR CONTOUR

SPOT ELEVATION837.50

CONCRETE PAVEMENT

CONTRACTOR WORK LIMITS

SOIL BORING

FO FIBER OPTICS

G G GAS

E E E E UNDERGROUND ELECTRIC

ES ES ES ES ES SECONDARY UNDERGROUND ELECTRIC

X X X X FENCE

SAN SAN SANITARY SEWER

SD SD STORM DRAIN

W W W W WATER MAIN

GENERAL NOTES:

1. SURVEY BASED ON MINNESOTA STATE STATE PLANE, SOUTH ZONE, US SURVEY

FEET, NAD83(2011). VERTICAL DATUM IS NAVD88. SURVEY DATE: 8/1/2023.

2. UNDERGROUND UTILITIES WERE CAPTURED FROM RECORD DRAWINGS AND

FIELD SURVEY. ACTUAL LOCATIONS MAY VARY FROM WHAT IS SHOWN HEREON.

CONTRACTOR MUST FIELD VERIFY ANY UTILITIES THAT MAY INTERFERE WITH

ALL EXCAVATIONS.

3. CONTRACTOR SHALL VERIFY THE POSITION OF SURVEY CONTROL POINTS

PRIOR TO CONSTRUCTION ACTIVITIES AND ESTABLISH NEW CONTROL POINTS

AS REQUIRED TO MAINTAIN SURVEY CONTROL FOR THE PROJECT AND SHALL BE

BASED ON THE PRIMARY CONTROL POINTS.

20' 40'

SCALE: 1 INCH = 20 FEET

10'20' 0'

A1 EXISTING SITE CONDITIONS

SCALE: 1" = 20'

US Army Corps of Engineers ®

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

A W

EB

ER

A W

EB

ER

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN NORTH

V-101

FI

LE

:F :\3

8\

5\

2\

_C

AD

\C

IV

L\

PL

O

T\

2_ V-

1.

dw g

PL

O

T D

AT

E:

6/

/2

Know what'sbelow Callbefore you dig.

www.call811.com

Know what'sbelow Callbefore you dig.

www.call811.com

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

W D

AW

SE

Y

J.

R

IT

TE

R

EX

IS

TI

N G

S

IT

E C

O N

D

IT

IO

N

S

CONTRACTOR WORK LIMITS

CONTRACTOR WORK LIMITS

CONTRACTOR

STAGING

AREA

MAGNAIL MAG NAIL CONTROL POINT

TREE STUMP

E E E E ABANDONED UNDERGROUND ELECTRIC

ES ES ES ES ES ABANDONED SECONDARY

UNDERGROUND ELECTRIC

07-01-2025

W

2Q R

BA

9_

Pl an s-

US Army Corps of Engineers ®

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

A W

EB

ER

A W

EB

ER

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B-101

FI

LE

:F :\3

8\

5\

2\

_C

AD

\C

IV

L\

PL

O

T\

2_ B-

1.

dw g

PL

O

T D

AT

E:

6/

/2

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

W D

AW

SE

Y

J.

R

IT

TE

R

A1 SOIL BORING LOGS

N.T.S.

SO

IL

B O

R

IN

G L

O G

S

07-01-2025

W

2Q R

BA

9_

Pl an s-

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

A W

EB

ER

A W

EB

ER

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

B-102

FI

LE

:F :\3

8\

5\

2\

_C

AD

\C

IV

L\

PL

O

T\

2_ B-

2.

dw g

PL

O

T D

AT

E:

6/

/2

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

W D

AW

SE

Y

J.

R

IT

TE

R

A1 SOIL BORING LOGS

N.T.S.

SO

IL

B O

R

IN

G L

O G

S

07-01-2025

W

2Q R

BA

9_

Pl an s-

G

CB

CO

C I D C

I

E

D

S U

U

E

IPIN

IPIN

MAGNAIL

MAGNAIL

MAGNAIL

FFE834.50

E

FFE834.30

S

E

G

FFE834.48

E

CB

CB

D

CB

D

G G

G

G G

G G

G G

G

W W W

W W

W W

W W

W W

W W

W

E

E

G G G

W W W W W W W W W W W W W W W W W W W W W W

G G G

G

G

G

X X X X X

X

X X X X X

SD SD SD SD SD SD

SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SAN

SAN

SAN SAN SAN SAN SAN

SA

N SAN

SAN

SAN

SAN

SAN

SANW

W

W W

W W W W W W W

W W W W W

W W W

W W

W W

W W

W W

WW

ES

ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES

E E E E E E E E E E E E E E E E E E E

E

E

E

E

E

E

E

E E

E E

W

ES ES ES ES ES ES ES ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES ES ES ES ES ES ES

FO

FO

FO FO

FO

E E

E E

E E

E E

E E

E E

E E E E E E E

FO

FO

FO

E E

E

C

C

S

SAN

SAN MH RIM 833.26

8" PVC 826.11(W)

8" PVC 826.16 (S)

6" PVC 826.86 (NE)

3" PVC 827.06 (E)

SAN MH RIM 833.85

8" PVC 827.65 (W)

8" PVC 827.65 (E)

4" PVC 827.60 (N)

SAN

SAN MH RIM 832.78

8" PVC 823.28 (E)

8" PVC 822.68 (N)

8" PVC 822.58 (S)

STM MH RIM 832.81

12" VCP 823.31 (N)

12" VCP 826.31 (W)

18" VCP 823.31 (S)

STM MH RIM 832.71

12" PVC 826.21 (NE)

12" RCP 824.31 (W)STM MH RIM 832.81

12" RCP 824.61 (E)

12" RCP 824.31 (S)

12" RCP 824.31 (W)

10" RCP 825.9 (NW)

12" RCP 828.21 (NW)

6" VCP 826.21 (NW)

SD SD

STM CB TOP 832.16

12" PVC 826.51 (W)

12" PVC 826.48 (N)

STM CB TOP 831.85

12" PVC 826.75 (S)

12" PVC 827.05 (N)

EMH TOP 833.39

BOT. 830.4

TOP COND. 832.2

ES

COMM MH 833.39

BOT. 825.8

BOT. T/SLAB (10") 831.1

COM MH 833.08

BOT. 826.23

BOT. T/SLAB (10") 831.1

SIXTH STREET

AP

O

LL

O

A

VE

N U

E

D O

O

LI

TT

LE

A

VE

N U

E

BUILDING 820

FFE 834.50

STM CB TOP 832.53

12" PVC 823.73 (N)

12" RCP 828.13 (W)

12" PVC 823.63 (S)

6" PVC 826.9 (S)

4" PVC 831.5 (SE)

ASPHALT DR.

CONC. DR.CONC. DR.

IPIN

N: 1019851.65 E: 2828626.33

Z: 833.17

IPIN

N: 1019798.72 E: 2828885.03 Z: 832.86

MAG NAIL

N: 1019628.39 E: 2828644.73

Z: 832.46

ASPHALT DR.

CONC.

DUMPSTER

PAD

GRASS

BLDG. 814

GRASS

CONC. WALK

GRASS

GRASS

GRASS

AS

PH

AL

T

D R

ASPHALT DRIVE

CONCRETE AIRFIELD RAMP

MAG NAIL

N: 1019655.87 E: 2828856.81

Z: 832.33BLDG. 822

BLDG. 807

CURB &

GUTTER

C U

R B

G

U

TT

ER

CURB &

GUTTER

CURB &

GUTTER

(ABAN.) STEAM MH 832.88

BOT. 826.7

BOT. T/SLAB (7") 831.4

PIV

E

EX RAMP LIGHT POLE

EX RAMP LIGHT POLE

AVIONICS B805

EXISTING

PARKING

LOT

BURIED

STRUCTURE

TO REMAIN

X

4 83

W W

EMH TOP 833.37

BOT. 828.0

BOT. T/SLAB (6") 832.3

SOIL - B-01 SOIL - B-02

SOIL - B-03

SOIL - B-04

SOIL - B-07SOIL - B-05

DEMO KEYNOTES

REMOVE CURB AND GUTTER

SAWCUT PAVEMENT FOR REMOVAL AND PROVIDE CLEAN EDGE

REMOVE BUILDING AND FOUNDATION

REMOVE TREE/VEGETATION

REMOVE CONCRETE

REMOVE FENCE AND SECURITY CURBING (IF APPLICABLE)

REMOVE ASPHALT

REMOVE SIDEWALK FOR NEW UTILITY INSTALLATION TO NEAREST

JOINT.

REMOVE SIDEWALK

REMOVE STORM STRUCTURE

REMOVE AND REPLACE FIBER OPTIC LINE. SEE COMMUNICATION

PLANS FOR DETAILS.

REMOVE BOLLARD

REMOVE ABANDONED UNDERGROUND ELECTRIC.

ABANDONED ELECTRIC CONDUIT TO REMAIN

REMOVE STORM DRAIN

PROTECT LIGHT/POLE DURING CONSTRUCTION

EXISTING AIR CONDITIONING TO BE PROTECTED DURING

CONSTRUCTION AND EXISTING COMPONENTS AND PAD TO BE

ADJUSTED TO GRADE

REMOVE BUILDING SIGN AND STORE FOR REINSTALLATION. SEE

C-101 FOR REINSTALLATION LOCATION.

1. ALL BOLD ITEMS ARE ASSUMED TO BE DEMO UNLESS OTHERWISE NOTED.

2. WHERE THE PLANS CALL FOR SAW CUTTING NEAT LINES ALONG THE EXISTING ASPHALT

SURFACES, THE SAW CUT SHALL BE FULL DEPTH. THE EXISTING PAVEMENT EDGE SHALL

BE SAW CUT TO LOCATE A SOUND PAVEMENT EDGE.

3. CONTRACTOR SHALL FIELD VERIFY DEPTH AND LOCATION OF ALL UNDERGROUND

UTILITIES PRIOR TO EXCAVATION AND SHALL PROTECT ALL EXISTING UTILITIES DURING

CONSTRUCTION. UTILITIES SHOWN ON THE DRAWINGS ARE BASED ON THE BEST

AVAILABLE INFORMATION AND MAY NOT REFLECT THE ACTUAL FIELD CONDITIONS OR

LOCATIONS OF UNDERGROUND STRUCTURES OR EXISTING UTILITIES. THE CONTRACTOR

SHALL BE RESPONSIBLE FOR ANY AND ALL DAMAGE TO EXISTING UTILITIES AND IS

RESPONSIBLE FOR IMMEDIATE REPAIR OF EXISTING PROJECT SITE UTILITY LINES

DAMAGED DURING CONSTRUCTION. REPAIRS SHALL BE MADE TO THE SATISFACTION

OF THE APPROPRIATE AFFECTED GOVERNMENT ENTITY OR UTILITY OWNER.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE NORMAL

OPERATING FUNCTIONS OF ALL UTILITY SYSTEMS THROUGH THE CONSTRUCTION SITE

DURING THE ENTIRE DURATION OF THE PROJECT.

5. ANY SOIL REMOVED AS PART OF THE WORK WILL NEED TO PROPERLY CHARACTERIZED

PRIOR TO DISPOSAL OFF-SITE. BORROW/DISPOSAL AREAS TO BE DETERMINED BY

CONTRACTING OFFICER.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR GROUNDS MAINTENANCE, INCLUDING

MOWING AND STANDARD HOUSEKEEPING, WITHIN THE PROJECT AREA THROUGHOUT

THE DURATION OF THE PROJECT.

7. THE CONTRACTOR SHALL MAINTAIN SITE SECURITY AND ABIDE BY ALL

MINNEAPOLIS-ST. PAUL AIR RESERVE STATION PROPERTY REGULATIONS.

8. ALL DEBRIS TO BE DISPOSED OFF-SITE.

9. SEE CS101 FOR LIMITS OF DISTURBANCE COORDINATES.

10. CONTRACTOR TO PROVIDE TEMPORARY STEEL PLATES FOR NEW UTILITY

TRENCHING ACROSS DOOLITTLE AVE UNTIL PAVEMENT IS REPLACED.

GENERAL NOTES:

DEMO LEGEND

REMOVE ASPHALT

REMOVE CONCRETE PAVEMENT

US Army Corps of Engineers ®

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

A W

EB

ER

A W

EB

ER

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN NORTH

CD101

FI

LE

:F :\3

8\

5\

2\

_C

AD

\C

IV

L\

PL

O

T\

2_ C

D

1.

dw g

PL

O T

D

AT

E:

6/

/2

Know what'sbelow Callbefore you dig.

www.call811.com

Know what'sbelow Callbefore you dig.

www.call811.com

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

W D

AW

SE

Y

J.

R

IT

TE

R

20' 40'

SCALE: 1 INCH = 20 FEET

10'20' 0'

A1 SITE DEMOLITION PLAN

SCALE: 1" = 20'

SI

TE

D

EM

O

LI

TI

O

N P

LA

N

7.5' 1

CONTRACTOR WORK LIMITS

CONTRACTOR WORK LIMITS

17 17

07-01-2025

W

2Q R

BA

9_

Pl an s-

CO

I

G

CB

CO

C I D C

I

E

D

S U

U

E

IPIN

IPIN

MAGNAIL

MAGNAIL

MAGNAIL

FFE834.50

E

FFE834.30

S

E

G

FFE834.48

E

CB

CB

D

W W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W W W W W W W W W W W W

X

X

X X X X X

SD SD SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SAN

SAN

SAN SAN SAN SAN SAN

SA

N SAN

SAN

SAN

SAN

SAN

SANW

W

W W

W W W W W W W

W W W W W

W W W

W W

W W

W W

W W

WW

ES

ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES

W

ES ES ES ES ES ES

ES

FO

FO

FO

FO

C

C

S

SAN

SAN

SD SD

ES

SIXTH STREET

AP

O

LL

O

A

VE

N U

E

D O

O

LI

TT

LE

A

VE

N U

E

BUILDING 820

FFE 834.50

ASPHALT DR.

IPIN

N: 1019851.65 E: 2828626.33

Z: 833.17

IPIN

N: 1019798.72 E: 2828885.03 Z: 832.86

MAG NAIL

N: 1019628.39 E: 2828644.73

Z: 832.46

CONC.

DUMPSTER

PAD

BLDG. 814

GRASS

CONC. WALK

GRASS AS

PH

AL

T

D R

ASPHALT DRIVE

CONCRETE AIRFIELD RAMP

MAG NAIL

N: 1019655.87 E: 2828856.81

Z: 832.33BLDG. 822

BLDG. 807

CURB &

GUTTER

C U

R B

G

U

TT

ER

CURB &

GUTTER

CURB &

GUTTER

PIV

EX RAMP LIGHT POLE

EX RAMP LIGHT POLE

AVIONICS B805

EXISTING

PARKING

LOT

BURIED

STRUCTURE

TO REMAIN

X

W W

SOIL - B-01 SOIL - B-02

SOIL - B-03

SOIL - B-04

SOIL - B-07SOIL - B-05

X X

X

X

X

FO

FO FO FO

U

G P

UGP UGP

U G

P

UGP UGP UGP

UGP

UGP

U G

P U

G P

U G

P

U G

P U

G P

1. ALL BOLD ITEMS ARE PROPOSED.

GENERAL NOTES:

US Army Corps of Engineers ®

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

A W

EB

ER

A W

EB

ER

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

PLAN NORTH

C-001

FI

LE

:F :\3

8\

5\

2\

_C

AD

\C

IV

L\

PL

O

T\

2_ C

-0

.d w g

PL

O T

D

AT

E:

6/

/2

Know what'sbelow Callbefore you dig.

www.call811.com

Know what'sbelow Callbefore you dig.

www.call811.com

M

IN

N

EA

PO

LI

S-

ST

P

AU

L

AI

R R

ES

ER

VE

S

TA

TI

O N

, M N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T P.

O . B

O X

L

O U

IS

VI

LL

E, K Y

1-

JU

LY

C

ER

TI

FI

ED

F

IN

AL

JU

LY

C O

N

ST

R U

C T

AD

D

IT

IO

N A

N D

R

EN

O

VA

TE

A

G E

FA

C

IL

IT

Y, B

P2 : 5

W D

AW

SE

Y

J.

R

IT

TE

R

20' 40'

SCALE: 1 INCH = 20 FEET

10'20' 0'

A1 AERIAL LAYOUT PLAN

SCALE: 1" = 20'

AE

R

IA

L

LA

YO

U T

P

LA

N

CONTRACTOR WORK LIMITS

PROPOSED LEGEND

CONCRETE STOOP

(SEE DETAIL K1/S-511)

SIDEWALK

(SEE DETAIL A1/C-501)

RIVER ROCK

(SEE DETAIL D16/C-501)

ASPHALT PAVEMENT

(SEE DETAIL K16/C-501)

3" MILL AND OVERLAY

GRAVEL MOW STRIP

(SEE DETAIL A8/C-501)

07-01-2025

W

2Q R

BA

9_

Pl an s-

I

G

CB

CO

C I D C

I

E

D

S U

U

E

IPIN

IPIN

MAGNAIL

MAGNAIL

MAGNAIL

FFE834.50

E

FFE834.30

S

E

G

FFE834.48

E

CB

CB

D

W W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W W W W W W W W W W W W

X

X

X X X X X

SD SD SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SAN

SAN

SAN SAN SAN SAN SAN

SA

N SAN

SAN

SAN

SAN

SAN

SANW

W

W W

W W W W W W W

W W W W W

W W W

W W

W W

W W

W W

WW

ES

ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES

W

ES ES ES ES ES ES

ES

FO

FO

FO

FO

C

C

S

SAN

SAN

SD SD

ES

SIXTH STREET

AP

O

LL

O

A

VE

N U

E

D O

O

LI

TT

LE

A

VE

N U

E

BUILDING 820

FFE 834.50

ASPHALT DR.

IPIN

N: 1019851.65 E: 2828626.33

Z: 833.17

IPIN

N: 1019798.72 E: 2828885.03 Z: 832.86

MAG NAIL

N: 1019628.39 E: 2828644.73

Z: 832.46

CONC.

DUMPSTER

PAD

BLDG. 814

GRASS

CONC. WALK

GRASS AS

PH

AL

T

D R

ASPHALT DRIVE

CONCRETE AIRFIELD RAMP

MAG NAIL

N: 1019655.87 E: 2828856.81

Z: 832.33BLDG. 822

BLDG. 807

CURB &

GUTTER

C U

R B

G

U

TT

ER

CURB &

GUTTER

CURB &

GUTTER

PIV

EX RAMP LIGHT POLE

EX RAMP LIGHT POLE

AVIONICS B805

EXISTING

PARKING

LOT

BURIED

STRUCTURE

TO REMAIN

X

W W

SOIL - B-01 SOIL - B-02

SOIL - B-03

SOIL - B-04

SOIL - B-07SOIL - B-05

X X

X

X

X

FO

FO FO FO

U

G P

UGP UGP

U G

P

UGP UGP UGP

UGP

UGP

U G

P U

G P

U G

P

U G

P U

G P

SITE KEYNOTES

PROPOSED CURB AND GUTTER (SEE DETAIL H1/C-501)

MECHANICAL/ELECTRICAL PAD. SEE MECHANICAL, ELECTRICAL,

ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR MORE DETAILS

PROPOSED BUILDING ADDITION. FFE 834.50

PROPOSED ELECTRIC MANHOLE. SEE ES101 FOR MORE DETAILS.

C3P TYPE CONTRACTION JOINT (SEE DETAIL H1/C-502)

PROPOSED SIDEWALK (SEE DETAIL A1/C-501)

RIVER ROCK (SEE DETAIL D16/C-501)

PROPOSED CONCRETE STOOP. SEE K1/S-511 FOR MORE DETAILS.

PROPOSED 7' FABRIC SECURITY FENCE (FE6-TR-84) (SEE DETAIL

A1/C-505)

THICKENED EDGE JOINT ABUTTING K1/S-511 (SEE DETAIL F13/C-503)

PROPOSED CURB AND GUTTER TIPOUT (SEE DETAIL H6/C-501)

GRAVEL MOW STRIP (SEE DETAIL A8/C-501)

STORM STRUCTURE. SEE SHEET CG102 FOR MORE DETAILS.

CONCRETE STEPS. SEE STRUCTURAL PLANS FOR MORE DETAILS.

PROPOSED ELECTRIC CONDUIT. SEE ES101 FOR MORE DETAILS.

REPLACE CONCRETE SIDEWALK TO NEAREST JOINT (SEE DETAIL

A1/C-501)

500 GAL. ABOVE GROUND STORAGE TANK. SEE PLUMBING

DRAWINGS FOR MORE DETAILS.

CONCRETE DUMPSTER PAD (SEE DETAIL B13/C-503)

PROPOSED TELECOM. SEE TS101 FOR MORE DETAILS.

PROPOSED BOLLARD (SEE DETAIL A14/C-501)

TRANSITION CUB FROM 6" TO 0" OVER 6'. SEE CG101 FOR GRADING.

PROPOSED 6'X6' CONCRETE PAD BENEATH STORAGE TANK. SEE

STRUCTURAL PLANS FOR MORE DETAILS.

3' X 4' CONCRETE PAD FOR NEW GAS METER

TELECOM MANHOLE. SEE TS101 FOR MORE DETAILS.

REINSTALL BUILDING SIGN

EXPANSION JOINT (SEE DETAIL A1/C-502)

1. ALL BOLD ITEMS ARE PROPOSED.

2. CONSTRUCTION FENCE SHALL BE PLACED TO ALLOW FOR ACCESS TO

BUILDINGS 807 AND 830 ON THE EAST SIDE OF THE WORK ZONE. ANY CLOSURE

PERIODS FOR CONSTRUCTION NEED TO BE COORDINATED WITH THE

GOVERNMENT.

3. CONTRACTOR TO PROVIDE TEMPORARY STEEL PLATES…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .