W912QR25BA019_Plans-0000.pdf
PDF 40 MB Posted
- Solicitation number
- W912QR25BA019
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
jo in t v e n t u re
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M
AR
K D
ES
C
R
IP
TI
O
N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
Au to de sk
D oc s:
//M
SP
A
R S
B8
A G
E R en ov at io n/
_0 2-
AR
C
H -M
SP
A
EJ
V
B8
_R
.rv t
7/ 2/
0:
:2
AM
G-001
C O
VE
R
S H
EE
T
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
J
KO
LS
H
O R
N
M H
AY
N
ES
J R
IT
TE
R
S D
U
FF
Y
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
LOUISVILLE DISTRICT
JULY 2025
CERTIFIED FINAL - JULY 2025
PROJECT SITE (B820)
MSP AIR RESERVE STATION
SITE VICINITY MAP
SCALE N/A
MSP
MILITARY HWY
5TH STREETLI
N
D
BE
R G
A
VE
N
SITE VICINITY MAP
SCALE N/A
N
MINNEAPOLIS-ST PAUL AIR RESERVE STATION, MN
CONSTRUCT ADDITION AND RENOVATE AGE
FACILITY, B820
P2: 509918
PROJECT #: QJKL210002
EXP. 1/31/2026
7-02-2025
28 July 2025
W912QR25BA019
W
2Q R
BA
9_
Pl an s-jo in t v e n t u re
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
Au to de sk
D oc s:
//M
SP
A
R S
B8
A G
E R en ov at io n/
_0 2-
AR
C
H -M
SP
A
EJ
V
B8
_R
.rv t
7/ 2/
0:
:0
AM
G-002
SH
EE
T
IN
D
EX
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
J
KO
LS
H
O R
N
M H
AY
N
ES
J R
IT
TE
R
S D
U
FF
Y
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
ARCHITECTURE
A-001 GENERAL NOTES AND ABBREVIATIONS
A-002 AIR BARRIER DIAGRAMS
A-003 AIR BARRIER DIAGRAMS
AD101 DEMOLITION PLAN
AD201 NORTH AND SOUTH DEMOLITION ELEVATIONS
AD202 EAST AND WEST DEMOLITION ELEVATIONS
A-101 FLOOR PLAN
A-102 PARTIAL FLOOR PLAN
A-103 PARTIAL FLOOR PLAN
A-111 ROOF PLAN
A-121 REFLECTED CEILING PLAN
A-122 PARTIAL REFLECTED CEILING PLAN
A-123 PARTIAL REFLECTED CEILING PLAN
A-201 NORTH AND SOUTH ELEVATIONS
A-202 EAST AND WEST ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-501 EXTERIOR ASSEMBLIES AND INTERIOR PARTITION DETAILS
A-510 DETAILS
A-511 DETAILS
A-550 OPENING DETAILS
A-601 OPENING SCHEDULE AND SIGNAGE DETAILS
STRUCTURAL
S-001 GENERAL NOTES - STRUCTURAL
S-002 GENERAL NOTES, DESIGN LOADS, AND
ABBREVIATIONS - STRUCTURAL
S-003 SPECIAL INSPECTIONS - STRUCTURAL
S-004 SPECIAL INSPECTIONS - STRUCTURAL
S-101 FOUNDATION PLAN
S-102 WASH BAY CEILING FRAMING PLAN
S-103 ROOF FRAMING PLAN
S-201 FRAMING ELEVATIONS
S-202 FRAMING ELEVATIONS
S-501 TYPICAL DETAILS - STRUCTURAL
S-502 TYPICAL DETAILS - STRUCTURAL
S-510 FOUNDATION DETAILS
S-511 FOUNDATION DETAILS
S-512 MECHANICAL PLATFORM & ROOF FRAMING DETAILS
S-513 ROOF FRAMING DETAILS
S-514 BASE PLATE & PEDESTAL DETAILS
S-515 FRAMING CONNECTION DETAILS
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
GI001 CODE REVIEW 1 OF 3 - LIFE SAFETY
GI002 CODE REVIEW 2 OF 3 - LIFE SAFETY
GI003 CODE REVIEW 3 OF 3 - LIFE SAFETY
GI100 SITE PLAN - LIFE SAFETY
GI101 FIRST FLOOR PLAN - NORTH - LIFE SAFETY
GI102 FIRST FLOOR PLAN - SOUTH - LIFE SAFETY
CIVIL
V-101 EXISTING SITE CONDITIONS
B-101 SOIL BORING LOGS
B-102 SOIL BORING LOGS
CD101 SITE DEMOLITION PLAN
C-001 AERIAL LAYOUT PLAN
C-101 SITE LAYOUT PLAN
CS101 SITE LOCATION PLAN
CG101 SITE GRADING PLAN
CG102 SITE DRAINAGE PLAN
CG103 EROSION AND SEDIMENT CONTROL PLAN
CG201 STORM PROFILES
C-501 SITE DETAILS
C-502 SITE DETAILS
C-503 SITE DETAILS
C-504 SITE DETAILS
C-505 SITE DETAILS
C-506 SITE DETAILS
C-507 SITE DETAILS
MECHANICAL
M-001 GENERAL INFORMATION - MECHANICAL
MD101 FIRST FLOOR PLAN - MECHANICAL - DEMOLITION
M-101 FIRST FLOOR PLAN - NORTH - MECHANICAL
M-102 FIRST FLOOR PLAN - SOUTH - MECHANICAL
M-301 SECTIONS - MECHANICAL
M-401 ENLARGED PLANS - MECHANICAL
M-501 DETAILS - MECHANICAL
M-601 SCHEDULES - MECHANICAL
M-601A SCHEDULES (BID OPTION 1) - MECHANICAL
M-701 CONTROLS - MECHANICAL
M-702 CONTROLS - MECHANICAL
M-703 CONTROLS - MECHANICAL
M-704 CONTROLS - MECHANICAL
M-705 CONTROLS - MECHANICAL
M-706 CONTROLS - MECHANICAL
M-707 CONTROLS - MECHANICAL
PLUMBING
P-001 GENERAL INFORMATION - PLUMBING
PD101 FIRST FLOOR PLAN - PLUMBING - DEMOLITION
P-101 FIRST FLOOR PLAN - NORTH - SANITARY
P-102 FIRST FLOOR PLAN - SOUTH - SANITARY
P-111 FIRST FLOOR PLAN - NORTH - DOMESTIC &
NATURAL GAS
P-112 FIRST FLOOR PLAN - SOUTH - DOMESTIC
P-501 DETAILS - PLUMBING
P-601 SCHEDULES - PLUMBING
ELECTRICAL
E-001 GENERAL INFORMATION - ELECTRICAL
ESD101 SITE PLAN - ELECTRICAL - DEMOLITION
ES101 SITE PLAN - ELECTRICAL
ED101 FIRST FLOOR PLAN - ELECTRICAL - DEMOLITION
ED701 DEMOLITION - DIAGRAMS - ELECTRICAL
EL101 FIRST FLOOR PLAN - NORTH - LIGHTING
EL102 FIRST FLOOR PLAN - SOUTH - LIGHTING
EP101 FIRST FLOOR PLAN - NORTH - POWER
EP101A FIRST FLOOR PLAN (BID OPTION 1) - NORTH - POWER
EP102 FIRST FLOOR PLAN - SOUTH - POWER
E-401 ENLARGED PLANS - ELECTRICAL
E-501 DETAILS - ELECTRICAL
E-601 SCHEDULES - ELECTRICAL
E-601A SCHEDULES (BID OPTION 1) - ELECTRICAL
E-700 DIAGRAMS - ELECTRICAL
E-701 DIAGRAMS - ELECTRICAL
E-701A DIAGRAMS (BID OPTION 1) - ELECTRICAL
TECHNOLOGY
T-001 GENERAL INFORMATION - TELECOMMUNICATIONS
TSD101 SITE PLAN - TELECOMMUNICATIONS - DEMOLITION
TS101 SITE PLAN - TELECOMMUNICATIONS
T-101 FIRST FLOOR PLAN - NORTH - TELECOMMUNICATIONS
T-102 FIRST FLOOR PLAN - SOUTH - TELECOMMUNICATIONS
T-401 ENLARGED PLANS - TELECOMMUNICATIONS
T-501 DETAILS - TELECOMMUNICATIONS
FIRE PROTECTION
F-001 GENERAL INFORMATION - FIRE PROTECTION
FD101 FIRST FLOOR PLAN - FIRE PROTECTION - DEMOLITION
FA101 FIRST FLOOR PLAN - NORTH - FIRE ALARM
FA102 FIRST FLOOR PLAN - SOUTH - FIRE ALARM
FA501 DETAILS - FIRE ALARM
FX101 FIRST FLOOR PLAN - NORTH - FIRE SUPPRESSION
FX102 FIRST FLOOR PLAN - SOUTH - FIRE SUPPRESSION
FX501 DETAILS - FIRE SUPPRESSION
7-02-2025
W
2Q R
BA
9_
Pl an s-
Fire Protection / Life Safety / Accessibility Code Review
FORM VERSION 27 DATED 8 OCTOBER 2020
MINNEAPOLIS-ST. PAUL ARMY RESERVE STATION BUILDING 820
1. PROJECT'S APPLIED CODES & STANDARDS
A. UFC 1-200-01: DOD BUILDING CODE, WITH CHANGE 3, 24 FEB 2023
B. UFC 3-600-01: DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE 6, 6 MAY 2021.
C. UFC 4-010-01: DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 3, 24 MAY 2024
D. UFC 4-021-01: DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, WITH CHANGE 1, JANUARY 2010
E. IBC 2021: INTERNATIONAL BUILDING CODE FOR FIRE RESISTANCE REQUIREMENTS, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITS, AND
BUILDING SEPARATION DISTANCE, EXCEPT AS MODIFIED BY UFC 3-600-01
F. NFPA 1, 2024: FIRE CODE, FOR DETERMINING VEHICLE ACCESS REQUIREMENTS
G. NFPA 101, 2024: LIFE SAFETY CODE, FOR BUILDING EGRESS AND LIFE SAFETY EXCEPT AS MODIFIED IN UFC 3-600-01
H. NFPA 10, 2022: STANDARD FOR PORTABLE FIRE EXTINGUISHERS
I. NFPA 13, 2022: STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS, MINIMUM REQUIREMENTS FOR DESIGN AND INSTALLATION OF
AUTOMATIC FIRE SPRINKLER SYSTEMS AND EXPOSURE PROTECTION
J. NFPA 30, 2024: FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, FOR CONSTRUCTION REQUIREMENTS AND FIRE RESISTANCE RATINGS FOR LIQUID
STORAGE AREAS
K. NFPA 30A, 2024: CODE FOR MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES, FOR OCCUPANCY CLASSIFICATION AND MEANS OF
EGRESS FOR REPAIR GARAGES AND ORGANIZATIONAL MAINTENANCE SHOPS
L. NFPA 70, 2023: NATIONAL ELECTRICAL CODE (NEC) - ARTICLE 500 HAZARDOUS LOCATIONS & ARTICLE 511 COMMERCIAL GARAGES, REPAIR &
STORAGE
M. NFPA 80, 2022: STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES
N. NFPA 72, 2022: NATIONAL FIRE ALARM AND SIGNALING CODE
O. NFPA 90A, 2024: STANDARD INSTALLATION OF AIR CONDITIONING & VENTILATION SYSTEMS, FOR PROTECTION OF OPENINGS, SHAFTS, FIRE
DAMPERS, SMOKE DAMPERS, PENETRATIONS AND FAN CONTROL
P. NFPA 291, 2022: RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS
Q. NFPA 400, 2022: HAZARDOUS MATERIAL CODE
R. ABA (ARCHITECTURAL BARRIERS ACT) ACCESSIBILITY STANDARDS, AS DIRECTED BY DOD POLICY MEMO "ACCESS FOR PEOPLE WITH
DISABILITIES" DATED 31 OCT 2008.
S. ECB 2018-17 WITH REV. 3 DATED 31 AUGUST 23: NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS NOTIFICATION SYSTEMS
T. LOUISVILLE DISTRICT MILITARY DESIGN GUIDE (LDMDG)
2. BUILDING CODE REQUIREMENTS:
A. OCCUPANCY CLASSIFICATION:
IBC CHAPTER 3
B. CONSTRUCTION TYPE: TYPE II-B
IBC CHAPTER 6
TABLE 601
C. MIXED USE & OCCUPANCY SEPARATIONS
UFC 3-600-01: 5-4, 5-5
IBC SECTION 508
D. AREA LIMITATIONS / MODIFICATIONS:
UFC 3-600-01: 5-3
IBC SECTION 506
E. HEIGHT LIMITATIONS:
IBC SECTION 503
TABLES 504.3 & 504.4
F. VERTICAL ENCLOSURES, CONTINUITY, PROTECTION: N/A
3-600-01: 3-3.1.1
NFPA 101: 7.1.3, 8.6
NFPA 90A: 4.3.1.2, 5.3.4
G. OPENING PROTECTIVES & THRU-PENETRATIONS
NFPA 101: 8.3 THRU 8.6
NFPA 90A
NFPA 80
NFPA 13
H. HORIZONTAL SEPARATIONS: N/A
IBC: TABLE 508.4
I. FIRE RESISTIVE REQUIREMENTS: INDICATE REQUIREMENTS BASED ON CONSTRUCTION TYPE:
IBC: TABLE 601 AND SECTION 602 PRIMARY STRUCTURAL FRAME - 0 HOUR RATING
EXTERIOR BEARING WALLS - 0 HOUR RATING
INTERIOR BEARING WALLS - 0 HOUR RATING
EXTERIOR NONBEARING PARTITIONS - 0 HOUR RATING
INTERIOR NONBEARING PARTITIONS - 0 HOUR RATING
FLOOR CONSTRUCTION & SECONDARY MEMBERS - 0 HOUR RATING
ROOF CONSTRUCTION & SECONDARY MEMBERS - 0 HOUR RATING
J. ENCLOSURE PROTECTION: N/A
NFPA 101: SPECIFIC OCCUPANCY CHAPTERS
ASME A17.1
UFC 3-600-01; 4-46.5.2.2
K. FIRE PROTECTION SYSTEM: THE ADDITION SHALL BE FULLY PROTECTED BY A WET-PIPE AUTOMATIC SPRINKLER
SYSTEM PER UFC 3-600-01 CHAPTER 9-7.
UFC 3-600-01: CHAPTERS 4 & 9
UFC 3-600-01: APPENDIX B
THE PROJECT WILL HAVE NO FIRE RATED PARTITIONS OR SMOKE RATED
PARTITIONS PROVIDED, SO THERE WILL BE NO REQUIRED OPENING PROTECTION
FOR THIS PROJECT. THE EXISTING BUILDING'S OFFICE AREA HAD DOOR FRAMES THAT
THE ADDITION AND EXISTING BUILDING WILL CONTAIN THE FOLLOWING OCCUPANCIES:
BUSINESS (WITHIN EXISTING BUILDING ONLY) - GROUP B
MODERATE STORAGE - GROUP S-1
MOTOR-VEHICLE-RELATED OCCUPANCY (WITHIN EXISTING BUILDING ONLY):
HEIGHT LIMITATION: (IBC TABLES 504.3 AND 504.4)
PERMITTED – FOR TYPE II-B CONSTRUCTION, IBC TABLE 504.3 LIMITS BUILDING HEIGHT
TO 75 FT FOR GROUPS B AND S OCCUPANCIES. FOR TYPE II-B CONSTRUCTION, IBC
TABLE 504.4 LIMITS BUILDING HEIGHT TO 4 STORIES FOR GROUP B AND S-1
OCCUPANCIES.
PROVIDED – THE BUILDING WITH THE NEW ADDITION IS 1 STORY AND 30’-4-1/2” IN
WITH THE TYPE OF EQUIPMENT TO BE STORED IN THE BUILDING,THE CODE REVIEW
DETERMINED THAT THE MAXIMUM ALLOWABLE QUANTITIES INDICATED IN NFPA 400
WAS NOT EXCEEDED AND THE PROJECT'S SPACE COULD BE CLASSIFIED AS "STORAGE".
BUILDING HEIGHT FOR THE EXISTING STRUCTURE WILL BE AFFECTED BY THE
ADDITION, AS THE ADDITION IS REQUIRED TO HAVE A 25'-0" INSIDE CLEAR SPACE FOR
AREA LIMITATION: (IBC SECTION 506)
PERMITTED – 70,000 SF (FOR S-1 FULLY SPRINKLERED OCCUPANCIES, FRONTAGE
INCREASE NOT NEEDED).
PROVIDED – 15,697 SF
THE BUILDING WILL BE A NON-SEPARATED MIXED USE OCCUPANCY CONSISTING
OF THE OCCUPANCIES INDICATED ABOVE. THE MOST RESTRICTIVE OCCUPANCY FOR
HEIGHT LIMITATION AND AREA LIMITATION (WHICH IS THE S-1 OCCUPANCY) WILL
BE UTILIZED FOR THIS BUILDING.
UFC 3-600-01; 9-7, EXCEPT AS MODIFIED IN CHAPTER 4 OF
UFC FOR SPECIFIC FACILITY TYPES
UFC 3-600-01; 1-12.12, 9-7.3.1.2, 4-46
N/A
NFPA 13
UFC 3-600-01: CHAPTER 9-7.4 COVERAGE PER SPRINKLER MUST BE IN ACCORDANCE WITH NFPA 13, NOT EXCEEDING
130 SF FOR THE ENTIRE AREA OF THE ADDITION. EXTENDED COVERAGE HEADS ARE
NFPA 13
THE JACK TEST STAND. THE MAXIMUM HEIGHT FOR THE ADDITION IS 30'-4-1/2".
THE ADDITION HAS AN APPROXIMATE FLOOR AREA OF 8,278 SF, PROVIDING A TOTAL
BUILDING FLOOR AREA OF 15,697 SF.
HEIGHT.
L. AVAILABLE WATER SUPPLY TESTING A FIRE FLOW TEST WAS CONDUCTED ON 15 OCTOBER 2024 AT AROUND 0800 CDT. THE
FLOW TEST RESULTED IN A STATIC PRESSURE OF 86 PSIG WITH 1,138 GPM AVAILABLE
AT A RESIDUAL PRESSURE OF 70 PSIG. PRELIMINARY HYDRAULIC CALCULATIONS
INDICATE THAT THE CURRENT WATER SUPPLY IS ADEQUATE TO SUPPORT THE FIRE
SPRINKLER SYSTEM. A FIRE PUMP WILL NOT BE REQUIRED FOR THIS PROJECT.
WATER SUPPLY MEETS FIRE FLOW REQUIREMENTS (1,000 GPM AT 20 PSI REQUIRED,
2,446 GPM AVAILABLE AT 20 PSI) OF UFC 3-600-01 SECTION 9-2.1.
UFC 3-600-01: 1-12.5, 9-6.4
NFPA 291
UFC 3-600-01: 9-2.2 N/A
NFPA 1: TABLE 18.4.5.2.1
UFC 3-600-01: 1-12.10, 4-40 N/A
M. WATER STORAGE TANK REQUIREMENTS N/A
UFC 3-600-01: 1-12.4, CHAPTER 9-4
NFPA 22
N. BACKFLOW PREVENTER & TESTING MINIMUM PRESSURE DROP ACROSS BACKFLOW PREVENTER IS 8 PSI FOR HYDRAULIC
CALCULATIONS.
NFPA 13: 8.16.4.6.1
UFC 3-600-01; 9-6.3.5, 9-6.6
O. FIRE PUMP(S) N/A
UFC 3-600-01: CHAPTER 9-5
NFPA 20
UFC 3-600-01: 9-5.1.4
NOT PERMITTED. SPRINKLER HEADS WILL BE PROVIDED WITH A K-FACTOR OF 11.2 FOR.
THE MAIN AREA AND 8.0 FOR THE CONNECTOR AND THE ELECTRICAL ROOM.
REPAIR GARAGES - GROUP S-1 (406.8)
WERE RATED FOR 1-1/2 HOURS, BUT IT COULD NOT BE DETERMINED IF THE ACTUAL
WALLS WERE FIRE RATED. ALSO, DOORS DID NOT APPEAR TO BE RATED, AND SOME
SPACES DID NOT EVEN HAVE DOORS INSTALLED IN THESE RATED FRAMES. WITH THIS
CODE REVIEW, THE RATED WALLS ARE NOT REQUIRED FOR THESE SPACES, AND NO
WORK WILL BE PERFORMED ON THESE WALLS. ALL EXISTING PENETRATIONS REUSED
FOR NEW WORK WILL BE SEALED TO MATCH EXISTING CONDITIONS.
UTILIZING STORAGE FOR THE BUILDING AND CLASS IV COMMODITIES, THE SPACE WILL
BE SET UP TO BE HYDRAULICALLY CALCULATED WITH THE WORST-CASE CONDITION
FOR THE STORAGE AREAS PER NFPA 13 CHAPTERS 4 AND 21, AS WELL AS UFC 3-600-01.
FOR THE HIGH-BAY AREA, THE ONLY REASON IT IS TO THE SCALE PROVIDED IS FOR A
SPECIFIC PIECE OF EQUIPMENT, ITS STORAGE CONDITIONS WOULD BE, AT WORST-
CASE, SIMILAR TO THE LOW-BAY AREA, SO WE WILL USE THE SAME DESIGN CRITERIA
FOR THE ENTIRE STORAGE AREA FOR CONSISTENCY (18 FT. HIGH STORAGE FOR THE
29 FT. HIGH PEAK HEIGHT SPACE).
FOR THE MAIN STORAGE AREA, SYSTEM WILL BE PROVIDED PER TABLE 21.2.2.2.1 WITH
CONTROL MODE DENSITY AREA (CDMA) SPRINKLERS WITH HIGH-TEMPERATURE-RATED
HEAD FOR A STORAGE HEIGHT UP TO 18 FT.:
0.27-GPM/SF OVER THE MOST REMOTE 2,000 SF PER THE TABLE
FOR THE CONNECTOR AREA, BEING THAT THE SPACE HEIGHT IS LESS THAN 12 FT.,
THIS SPACE WILL BE PROTECTED PER TABLE 4.3.1.7.1.1 AS SOLID-PILED STORAGE FOR
STORAGE HEIGHTS UP TO 12 FT.. THAT HAS A REQUIREMENT OF ORDINARY HAZARD
PROTECTION FOR THE AREA.
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:2
P M
GI001
C O
D E
R E
V
IE
W
O F
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
8 W
2Q
R
BA
9_ Pl an s-
3. LIFE SAFETY REQUIREMENTS:
A. CLASSIFICATION OF OCCUPANCY: THE ADDITION AND EXISTING BUILDING WILL CONTAIN MIXED OCCUPANCIES
(NON-SEPARATED) CONSISTING OF THE FOLLOWING OCCUPANCIES:
BUSINESS
(WITHIN EXISTING BUILDING ONLY)
STORAGE
INDUSTRIAL (REPAIR GARAGE, WITHIN
EXISTING BUILDING ONLY)
NFPA 101: CH. 6
B. OCCUPANT LOAD:
NFPA 101: 7.3.1.2 & CHAPTERS 12-42
UFC 3-600-01: 10-3.1
C. CAPACITY OF MEANS OF EGRESS:
NFPA 101: 7.3.3 & CHAPTERS 12-42
D. NUMBER OF EXITS: MINIMUM OF 2 EXITS REQUIRED FOR THE EXISTING BUILDING. 11 EXITS PROVIDED.
SINGLE MEANS OF EGRESS IS PERMITTED IN STORAGE OCCUPANCIES WHEN EXIT CAN
BE REACHED WITHIN 100 FEET (COMMON PATH OF TRAVEL).
NFPA 101: 7.4 & CHAPTERS 12-42
E. ARRANGEMENT OF MEANS OF EGRESS MEANS OF EGRESS WILL COMPLY WITH NFPA 101. BUILDING WILL BE PROTECTED WITH
AUTOMATIC FIRE SPRINKLERS THROUGHOUT.
NFPA 101: 7.5 & CHAPTERS 12-42
F. ACCESSIBLE MEANS OF EGRESS NOT LESS THAN 2 ACCESSIBLE MEANS OF EGRESS REQUIRED. 2 ACCESSIBLE MEANS
OF EGRESS PROVIDED.
NFPA 101: 7.5.4
G. TRAVEL DISTANCE TO EXITS:
NFPA 101: 7.6 & CHAPTERS 12-42
H. ILLUMINATION OF MEANS OF EGRESS: ALL EXITS SHALL BE PROVIDED WITH EMERGENCY ILLUMINATION. ILLUMINATION OF
MEANS OF EGRESS SHALL BE PROVIDED AT ALL TIMES DURING OCCUPANCY.
NFPA 101: 7.8 & CHAPTERS 12-42
I. EMERGENCY LIGHTING:
NFPA 101: 7.9 & CHAPTERS 12-42
J. MARKING OF MEANS OF EGRESS:
NFPA 101: 7.10 & CHAPTERS 12-42
K. INTERIOR FINISH CLASSIFICATION LIMITS:
NFPA 101: TABLE A.10.2.2
L. DETECTION, ALARM, & COMMUNICATIONS: THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS), BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A
FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE
DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO
REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE
BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE
NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY
REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET
AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN
EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING
IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES
SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.
ALSO, WITHIN THE EXISTING SPRINKLER RISER ROOM, A NEW LOW-TEMPERATURE
DEVICE WILL BE PROVIDED IN THE SPACE TO ALERT THE FIRE ALARM REPORTING
STATION THAT AN ISSUE IS OCCURRING IF THE TEMPERATURE DROPS BELOW THE
DEVICE'S SET-POINT.
CO DETECTORS WILL BE PROVIDED WITHIN THE EXISTING BUILDING AND THE
ADDITION PER UFC 3-600-01.
UFC 3-600-01: CHAPTER 9-18
NFPA 101: 9.6 & CHAPTERS 12-42
M. PORTABLE FIRE EXTINGUISHERS: PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WITHIN THE ADDITION WHERE
REQUIRED PER NFPA 101. FIRE EXTINGUISHERS SHALL BE SIZED AND LOCATED IN
ACCORDANCE WITH NFPA 10.UFC 3-600-01, 9-17
NFPA 10
N. CORRIDORS: NO RATINGS REQUIRED.
NFPA 101: CHAPTERS 12-42
O. FIRE DAMPERS: N/A, AS THERE ARE NO FIRE RATED CONSTRUCTION TO BE PROVIDED FOR THIS
BUILDING.
NFPA 90A: 5.3.1, 5.4.1 & 5.4.2
P. SMOKE DAMPERS: N/A, AS THERE ARE NO SMOKE RATED CONSTRUCTION TO BE PROVIDED FOR THIS
BUILDING.
IBC: SECTION 716
NFPA 90A: 4.3.10.2, 5.3.5.1
Q. DUCT SMOKE DETECTORS
NFPA 90A: 6.4.2.1
R. ELEVATORS N/A
UFC 3-600-01: 4-13
IBC CHAPTER 30
ASME A17.1
NFPA 13
UFC 3-490-06: 3-3.1
S. ROOF ACCESS: N/A
UFC 3-600-01: 10-4
IBC CHAPTER 1011.12
T. HAZARDOUS LOCATIONS IN COMMERCIAL GARAGES N/A
NFPA 70: NEC ARTICLES 500 & 511
U. FIRE DEPT. VEHICLE ACCESS FIRE DEPARTMENT VEHICLES MUST HAVE UNIMPEDED ACCESS TO THE BUILDING
FROM AT LEAST ONE DIRECTION FOR EMERGENCY VEHICLE ACCESS. ACCESS SHALL
TERMINATE NO FURTHER THAN 33 FEET FROM THE BUILDING. PAVED AREAS PROVIDE
ACCESS TO ALL TWO SIDES OF THE BUILDING.
UFC 3-600-01: 9-1
NFPA 1: 18.2.3.4.1
V. FIRE HYDRANT INSTALLATION THE FDC MUST BE LOCATED WITHIN 150’ OF A FIRE HYDRANT PER UFC 3-600-01.
EXISTING FDC MEETS THIS REQUIREMENT.
UFC 3-600-01: 9-3.5
W. KITCHEN COOKING EXHAUST EQUIPMENT N/A
NFPA 101: 9.2.3, CHAPTERS 12-42
NFPA 96
OCCUPANT LOAD CALCULATION BELOW INCLUDES BOTH THE ADDITION AND THE
EXISTING BUILDING. OCCUPANT LOAD FACTORS ARE IN ACCORDANCE WITH NFPA 101
EXCEPT AS MODIFIED BY UFC 3-600-01.
MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES:
517 SF / 500 SF OCCUPANT = 1.03 OCCUPANTS
BUSINESS: 889 SF / 150 SF / OCCUPANT = 5.93 OCCUPANTS
STORAGE (INCLUDING JACK TEST STAND AND TOOL CRIB):
INDUSTRIAL(MAINTENANCE AREA, WASH BAY, PARTS CLEANING, BATTERY
2,787 SF / 100 SF / OCCUPANT = 27.87 OCCUPANTS
CALCULATED OCCUPANT LOAD: 58 OCCUPANTS.
NFPA 101 EXIT CAPACITIES (ADDITION AND EXISTING BUILDING)
EXIT DOOR = 34" OPENING (36" DOOR) / 0.2 IN/OCCUPANT = 170 OCCUPANTS
11 EXIT DOORS FOR ADDITION AND EXISTING BUILDING (NOT COUNTING MECHANICAL
OR ELECTRICAL ROOM)
BUILDING EXIT CAPACITY = 1,870 OCCUPANTS
EMERGENCY EGRESS LIGHTING WILL BE PROVIDED IN ACCORDANCE WITH NFPA 101
§7.9. THE EMERGENCY LIGHTING WILL BE PROVIDED FOR 1 ½ HOURS UPON THE
FAILURE OF NORMAL LIGHTING. INITIAL LIGHTING LEVELS WILL BE NOT LESS THAN AN
AVERAGE OF 1 FT-CANDLE AND NOT LESS THAN 0.1 FT-CANDLE ALONG THE PATH OF
EGRESS (AT FLOOR LEVEL). THESE LEVELS ARE PERMITTED TO DECLINE TO NOT LESS
THAN AN AVERAGE OF 0.6 FT-CANDLE AND NOT LESS THAN 0.06 FT-CANDLE ALONG THE
PATH OF EGRESS (AT FLOOR LEVEL) UNTIL 1 ½ HOURS HAVE PASSED.
THE EMERGENCY LIGHTING SYSTEM WILL BE AT LEAST TYPE 10, CLASS 1.5, LEVEL 1 IN
ACCORDANCE WITH NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER
SYSTEMS.
EMERGENCY LIGHTING WILL BE SHOWN ON ELECTRICAL PLANS FOR CLARITY AND
CIRCUITING. LIFE SAFETY PLANS WILL REFERENCE ELECTRICAL PLANS FOR
EMERGENCY LIGHTING.
THE MEANS OF EGRESS WILL BE MARKED IN ACCORDANCE WITH NFPA 101 §7.10 AND
UFC 3-600-01 §10-2. EACH EXIT DOOR WILL BE MARKED BY AN EXIT SIGN VISIBLE FROM
ANY DIRECTION OF EXIT ACCESS. ADDITIONAL EXIT SIGNS WILL BE PROVIDED ALONG
EXIT ACCESS PATHS WHERE THE PATH IS NOT OBVIOUS.
EXIT SIGNS WILL BE LIGHT EMITTING DIODE (LED), ELECTROLUMINESCENCE (LEC) OR
COLD CATHODE TYPE. INCANDESCENT TYPE EXIT SIGNS WILL NOT BE USED.
EXIT SIGNS WILL BE SHOWN ON THE ELECTRICAL PLANS (FOR CIRCUITING) AND THE
LIFE SAFETY PLANS.
TACTILE SIGNAGE READING “EXIT” WILL BE PROVIDED AT EACH EXIT DOOR. THESE
SIGNS SHALL COMPLY WITH ICC / ANSI A117.1, AMERICAN NATIONAL STANDARD FOR
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES.
TACTILE SIGNS WILL BE SHOWN ON THE INTERIOR DESIGN SIGNAGE PLANS.
CLASS A, B, OR C FOR RATED CORRIDORS.
CLASS A, B, OR C FOR OTHER AREAS.
FLOOR FINISH TYPE 1 OR 2.
SMOKE DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE
LOCATED AS FOLLOWS:
DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN AIR
SUPPLY STEMS HAVING A CAPACITY GREATER THAN 2000 CFM.
11,504 SF / 500 SF / OCCUPANT = 23.01 OCCUPANTS
MEASURE - BUSINESS:
MAXIMUM TRAVEL DISTANCE = 300'
MAXIMUM COMMON PATH OF TRAVEL = 100'
MAXIMUM DEAD END = 50'
MEASURE - INDUSTRIAL (GENERAL PURPOSE):
MAXIMUM TRAVEL DISTANCE = 250'
MAXIMUM COMMON PATH OF TRAVEL = 100'
MAXIMUM DEAD END = 50'
MEASURE - STORAGE OCCUPANCY:
MAXIMUM TRAVEL DISTANCE = 400'
MAXIMUM COMMON PATH OF TRAVEL = 100'
MAXIMUM DEAD END = 50'
MEASURE - MECHANICAL PLATFORM (MECHANICAL ROOM PER SECTION 7.13):
MAXIMUM TRAVEL DISTANCE = 50'
(REFER TO SHEET GI103 FOR TABULATED OCCUPANT COUNT
PER SPACE/AREA)
ROOM, AND RESTROOMS):
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:2
P M
GI002
C O
D E
R E
V
IE
W
O F
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
8 W
2Q
R
BA
9_ Pl an s-
OCCUPANT COUNT
SPACE
BUSINESS GROUP
OFFICE AREA (X-110, X-112, X-113)
NUMBER OF OCCUPANTS
150 SF / OCCUPANT
5.74
MECHANICAL/ELECTRICAL
- X-112 IS UTILIZED AS OPEN OFFICE
COMM/ELECTRICAL (X-115, X-109)
MECHANICAL/SPRINKLER (X-107, X-108)
SQUARE FOOTAGE
500 SF / OCCUPANT
0.33
0.36
STORAGE AREA
TOOL CRIB (X-111)
MATERIAL STORAGE (X-117)
500 SF / OCCUPANT
0.43
0.54
INDUSTRIAL AREA
BATTERY ROOM (X-116)
RESTROOMS (ADJACENT TO THIS AREA) (X-105, X-106)
100 SF / OCCUPANT
0.70
6.13
TOTAL CALCULATED OCCUPANT LOAD = 57 OCCUPANTS
ELECTRICAL (102) 0.31157
OPEN STORAGE (MINUS REPAIR AREA) (X-104, 100) 21.3510,674
WASH BAY (101) 7.76776
REPAIR AREA OF OPEN STORAGE (X-104) 11.471,147
PARTS CLEANING (X-114) 0.9797
4. EXISTING FACILITIES:
A. EXISTING FACILITY DEFICIENCY UPGRADE: FACILITIES AS THEY EXIST PRIOR TO PROJECT, MUST MEET NFPA 101 FOR EXISTING
OCCUPANCY. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EVERY
EXISTING BUSINESS OCCUPANCY PER NFPA 101. ADDITIONAL FIRE EXTINGUISHERS
WILL BE PROVIDED IN THE EXISTING BUILDING TO SATISFY THIS REQUIREMENT.
UFC 3-600-01: 34-1.1
NFPA 101: CHAPTERS 12-42
B. WORK IN EXISTING FACILITIES:
UFC 3-600-01: 34-1.2.1
NFPA 101, CHAPTER 43, REPAIR N/A
NFPA 101, CHAPTER 43, RENOVATION THE EXISTING FIRE ALARM AND MASS NOTIFICATION SYSTEM WILL BE COMPLETELY
REMOVED FROM THE EXISTING BUILDING AND A NEW SYSTEM WILL BE INSTALLED,
COMPLYING TO THE REQUIREMENTS OF UFC 3-600-01 AND NFPA 72. THE BUILDING'S
OFFICE AREA WILL ALSO MEET THE INTELLIGIBILITY REQUIREMENTS FOR A MASS
NOTIFICATION SYSTEM PER UFC 4-021-01.
NFPA 101, CHAPTER 43, MODIFICATION THE EXISTING BUILDING WILL HAVE AN EXISTING ADDITION TO THE MAIN BUILDING
REMOVED, AS WELL AS THE REMOVAL OF A SEGMENT OF THE NE EXTERIOR WALL AND
A SECTION OF INTERIOR WALL ABOUT 20 FT LONG WITHIN THE EXISTING
SHOP/STORAGE AREA. NONE OF THESE MODIFICATION WILL AFFECT THE REMAINING
EXISTING BUILDING FLOOR AREA.
NFPA 101, CHAPTER 43, RECONSTRUCTION N/A
UFC 3-600-01: 34-1.2.8 THE AREA OF THE MODIFICATION WITHIN THE EXISTING REMAINING BUILDING IS
NEGLIBILE IN AREA.
UFC 3-600-01:34-1.2.9 N/A
NFPA 101, CHAPTER 43, ADDITION THE ADDITION SHALL BE SPRINKLERED THROUGHOUT AS REQUIRED BY UFC 3-600-01
SECTION 9-7.2.4. THE FIRE ALARM SYSTEM WILL ALSO BE EXTENDED TO COVER THE
ENTIRE ADDITION.
C. CHANGE IN USE CATEGORY: N/A
UFC 3-600-01:34-1.3
D. VACANT BLDG. CATEGORY: N/A
UFC 3-600-01:34-1.4
E. PHASED PROJECTS: N/A
UFC 3-600-01:34-2
F. COOKING AREAS: N/A
UFC 3-600-01:34-3
G. ELECTRONIC EQUIPMENT AREAS: N/A
UFC 3-600-01:34-5
H. AUTOMATIC SPRINKLER SYSTEMS: EXISTING BUILDING AND ADDITION SHALL BE SPRINKLERED THROUGHOUT PER UFC
3-600-01 SECTIONS 9-7.2.4 AND 9-7.2.1.1.
UFC 3-600-01: 34-1.2.6 & 9-7.2
I. FIRE ALARM SYSTEM:
THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS),
BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A
FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE
DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO
REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE
BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE
NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY
REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET
AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN
EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING
IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES
SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.
ALSO, WITHIN THE EXISTING SPRINKLER RISER ROOM, A NEW LOW-TEMPERATURE
DEVICE WILL BE PROVIDED IN THE SPACE TO ALERT THE FIRE ALARM REPORTING
STATION THAT AN ISSUE IS OCCURRING IF THE TEMPERATURE DROPS BELOW THE
DEVICE'S SET-POINT.
CO DETECTORS WILL BE PROVIDED WITHIN THE EXISTING BUILDING AND THE
ADDITION PER UFC 3-600-01.
UFC 3-600-01:34-1.2.8 & 9-18
5. MASS NOTIFICATION:
UFC 4-021-01 THE EXISTING BUILDING HAS A FIRE ALARM MASS NOTIFICATION SYSTEM (FA/MNS), BUT DUE TO THE FACT THAT THE EXISTING SYSTEM IS CURRENTLY PROVIDED WITH A
FIRE ALARM NOTIFICATION AND A MASS NOTIFICATION SYSTEM WITH TWO SEPARATE
DEVICES, AS WELL AS THE AGE OF THE EXISTING SYSTEM, THE DECISION IS TO
REMOVE THE EXISTING SYSTEM AND PROVIDE A NEW FA/MNS FOR THE ENTIRE
BUILDING. THE ENTIRE BUILDING WILL BE PROVIDED WITH SPEAKER/STROBE
NOTIFICATION THROUGHOUT WITH VOICE ALERT, EVEN THOUGH INTELLIGIBILITY
REQUIREMENTS WILL ONLY BE ACHIEVED WITHIN WITHIN THE ADMIN. AND TOILET
AREA. THERE WILL ALSO BE LED EVACUATION/ ANNOUNCEMENT SIGNS AT THE MAIN
EGRESS DOORS. SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING
IN LIEU OF THE HORNS CURRENTLY PROVIDED ON THE BUILDING. ALL FA/MNS DEVICES
SHALL BE PROVIDED AS REQUIRED BY UFC 3-600-01, UFC 4-010-01, AND NFPA 72.
ECB 2018-17
6. ACCESSIBILITY REQUIREMENTS:
ABA CHAPTERS 1-10 THE FIRE ALARM MASS NOTIFICATION SYSTEM SHALL HAVE PERMANENTLY INSTALLED
AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72, EXCEPT THAT THE
MAXIMUM ALLOWABLE SOUND LEVEL OF AUDIBLE NOTIFICATION APPLIANCES SHALL
NOT HAVE A SOUND LEVEL EXCEEDING 110 DB AT THE MINIMUM HEARING DISTANCE
FROM THE AUDIBLE APPLIANCE.
LIFE SAFETY SYMBOLS
ACTUAL EGRESS CAPACITY
NOTE: NOT ALL SYMBOLS MAY BE USED
DESCRIPTIONSYMBOL COMMENTS
EGRESS CAPACITY
THROUGH DOORWAY
TRAVEL DISTANCE
EGRESS DOORS @ WIDTH (IN.)
EGRESS CAPACITY (OCCUPANTS)
X @ XX
XXX
XX = XX'-X" TD = TRAVEL DISTANCE
CT = COMMON PATH OF TRAVEL
DE = DEAD END
XX
PORTABLE FIRE
EXTINGUISHER
BASIC SHAPE, SEE
DRAWINGS FOR TYPE
REQUIREMENTS
END OF COMMON PATH
EXIT SIGN - SHADING
INDICATES FACE, ARROW
INDICATES DIRECTION
XXX'-X' HOSE PATH AND LENGTH
FROM HYDRANT TO END OF
LINE
LIFE SAFETY SYMBOLS
WALL - BASIC SHAPE
NOTE: NOT ALL SYMBOLS MAY BE USED
SSMOKE-RATED WALL
1/2-HOUR FIRE-RATED WALL
1/2-HOUR FIRE / SMOKE-RATED WALL S
3/4-HOUR FIRE-RATED WALL
3/4-HOUR FIRE / SMOKE-RATED WALL S
1-HOUR FIRE-RATED WALL
1-HOUR FIRE / SMOKE-RATED WALL S
2-HOUR FIRE-RATED WALL
2-HOUR FIRE WALL
F
2-HOUR FIRE / SMOKE-RATED WALL S
3-HOUR FIRE-RATED WALL
3-HOUR FIRE WALL
F
3-HOUR FIRE / SMOKE-RATED WALL S
4-HOUR FIRE-RATED WALL
4-HOUR FIRE WALL
F
4-HOUR FIRE / SMOKE-RATED WALL S
FIRE EXTINGUISHER REQUIREMENTS
UNIT SIZE
(POUNDS)
RATING COVERAGE AREA BASED ON
OCCUPANT HAZARD
NUMBER OF UNITS
REQUIRED
NUMBER OF UNITS
PROVIDED
MAXIMUM TRAVEL
DISTANCE
75 FEET753,000 ORDINARY
6,000 LIGHT
2A:10B:C5
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:3
P M
GI003
C O
D E
R E
V
IE
W
O F
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
8 W
2Q
R
BA
9_ Pl an s-
S
SS
E
E
E
E
E
G
G
C
C
FFE
FFE
FFE
834.50
834.30
834.48
U
U
D
D
D
C I
CB
CB
C I C
I
CB
MAGNAIL
MAGNAIL
MAGNAIL
IPIN
IPIN
CO
PIV
HYDRANT 46
HYDRANT 51
215'-7"
307'-7"
145'-2"
161'-2"
199'-0"
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:3
P M
GI100
S
IT
E P
L A
N
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
GENERAL SHEET NOTES
1. REFER TO DRAWING GI003 FOR SYMBOLS.
2. THERE IS NO WATER STORAGE TANK, HAZARDEOUS MATERIAL
SPILL CONTAINMENT TANKS, OR FIRE PUMP TO BE PROVIDED
FOR THIS PROJECT.
3. EXISTING BACKFLOW PREVENTER ASSEMBLY IS LOCATED
WITHIN THE BUILDING.
SHEET KEYNOTES
1. HYDRANT 58, UTILIZED AS THE FLOW HYRANT FOR THE FLOW
TEST, IS LOCATED FURTHER SOUTH ON THE SITE. THE
HYDRANT IS LOCATED APPROXIMATELY 192' FROM
SOUTHWESTERN CORNER OF THE EXISTING BUILDING.
2. HYDRANT 66, UTILIZED AS THE GAUGE (PRESSURE) HYDRANT
FOR THE FLOW TEST.
3. 6" WATER SERVICE FOR THE BUILDING.
4. FIRE TRUCK ACCESS VIA THE AIRFIELD.
5. FIRE DEPARTMENT ACCESS INTO THE BUILDING.
6. EXISTING SITE FENCE WITH SECURITY CONTROLLED GATE
ACROSS DOOLITTLE AVENUE.
7. SITE FENCE FROM BUILDING 820 AND ACROSS APOLLO
AVENUE.
8. EXISTING FIRE DEPARTMENT CONNECTION ON BUILDING,
HOSE LENGTH TO HYDRANT IS 136'-6".
9. LOCATION OF EXISTING POST INDICATOR VALVE.
NORTH
SCALE: 1" = 20'-0"
A2
SITE PLAN - LIFE SAFETY
0 10' 20' 40'
W
2Q R
BA
9_
Pl an s-
1 @ 34
1 @ 34
1 @ 34
TD = 87'-4"
T D
2 @ 68
LOW BAY
STORAGE
ELEC
WASH BAY
2.1 3 4 5
AA
BB
5.9 6.9
FF
EE
DD
CC
TD = 94'-8"
MULE
MAINTENANCE
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:3
P M
GI101
F
IR
S T
F L O
O R
P L A
N
N O
R T
H
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
GENERAL SHEET NOTES
1. REFER TO DRAWING GI003 FOR SYMBOLS.
SHEET KEYNOTES
1. TOP OF WASH BAY IS 16'-0" ABOVE FINISHED FLOOR AND IS A
MECHANICAL PLATFORM. MEANS OF EGRESS PATH IS FROM
ACCESS SIDE OF MAU-03, REFER TO SHEET M-101 FOR
ADDITIONAL INFORMATION. TRAVEL DISTANCE INCLUDES A
VERTICAL TRAVEL DISTANCE OF 13'-6" PLUS HORIZONTAL
TRAVEL DISTANCE SHOWN.
2. SHIPS LADDER FOR ACCESS TO MECHANICAL PLATFORM,
REFER TO ARCHITECTURAL SHEETS FOR MORE INFORMATION.
3. FOR EXIT POINT OF TRAVEL DISTANCE LINE, REFER TO FIRST
FLOOR PLAN - SOUTH - LIKE SAFETY PLAN ON SHEET GI102.
4. FIRE EXTINGUISHER LOCATED ON MECHANICAL PLATFORM
ABOVE WASH BAY.
NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR PLAN - NORTH - LIFE SAFETY
W
2Q R
BA
9_
Pl an s-
1 @ 34
1 @ 34
0 1
1 @ 34
T D
TD = 124'-2"
15 16
CLASSROOM
COMPUTER
X-112
OFFICE
X-113
BATTERY
X-116
HALL
X-110
PARTS CLEANING
X-114
COMM
X-115
ELEC
X-109
EXISTING
STORAGE
X-104
WOMENS
X-106
MENS
X-105
MECHANICAL
X-107
SPRINKLER
X-108
MATERIAL
STORAGE
X-117
2.1 3 4 5 62
AA
A
B
TOOL CRIB
X-111
BOWMAN
E-81028
JOHN
PHILIP
O
H
I
OFO
S
TA
ET
E R
E I
E
E
R E
N
G
ND
P R
SI
G
S F
E
S
E
O
R
T
I O N A L j o i n t v e n t u r e
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
KEY PLAN
07/01/2025
A u to d e s k D o c s
/M S
P A
R S
B A
G E
R e n o v a ti o n /M
S P
A E
J V
B v
M E
P F
T .r v t
/1
/2
:4
:4
P M
GI102
F
IR
S T
F L O
O R
P L A
N
S O
U T
H
L
IF
E S
A F
E T
Y
M
IN
N E
A P
O L
IS
-S T
P A
U L A
IR
R
E S
E R
V E
S T
A T
IO
N
M
N L O
U
IS
V
IL
L E
D
IS
T R
IC
T
P .O
B
O X
L
O U
IS
V
IL
L E
K
Y
-0
P B
O W
M A
N
P B
O W
M A
N
J R
IT
T
E R
J L E
E
M A
Y
C E
R T
IF
IE
D F
IN
A
L
J U
L Y
C O
N S
T R
U C
T A
D D
IT
IO
N A
N D
R E
N O
V A
T E
A G
E F
A C
IL
IT
Y
B
P
GENERAL SHEET NOTES
1. REFER TO DRAWING GI003 FOR SYMBOLS.
SHEET KEYNOTES
1. FOR STARTING POINT OF TRAVEL DISTANCE LINE, REFER TO
FIRST FLOOR PLAN - NORTH - LIKE SAFETY PLAN ON SHEET
GI101.
2. FIRE EXTINGUISHER LOCATED ON EXISTING MEZANNINE.
NORTH
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
FIRST FLOOR PLAN - SOUTH - LIFE SAFETY
W
2Q R
BA
9_
Pl an s-
C I
G
CB
CO
C I D C
I
E
D
S U
U
E
IPIN
IPIN
MAGNAIL
MAGNAIL
MAGNAIL
FFE834.50
E
FFE834.30
S
E
G
FFE834.48
E
CB
CB
D
CB
D
G G
G
G G
G G
G G
G
W W W
W W
W W
W W
W W
W W
W
E
E
G G G
W W W W W W W W W W W W W W W W W W W W W W
G G G
G
G
G
X X X X X
X
X X X X X
SD SD SD SD SD SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SAN
SAN
SAN SAN SAN SAN SAN
SA
N SAN
SAN
SAN
SAN
SAN
SANW
W
W W
W W W W W W W
W W W W W
W W W
W W
W W
W W
W W
WW
ES
ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES
E E E E E E E E E E E E E E E E E E E
E
E
E
E
E
E
E
E E
E E
W
ES ES ES ES ES ES ES ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES ES ES ES ES ES ES
FO
FO
FO FO
FO
E E
E E
E E
E E
E E
E E
E E E E E E E
FO
FO
FO
E E
E
C
C
S
SAN
SAN MH RIM 833.26
8" PVC 826.11(W)
8" PVC 826.16 (S)
6" PVC 826.86 (NE)
3" PVC 827.06 (E)
SAN MH RIM 833.85
8" PVC 827.65 (W)
8" PVC 827.65 (E)
4" PVC 827.60 (N)
SAN
SAN MH RIM 832.78
8" PVC 823.28 (E)
8" PVC 822.68 (N)
8" PVC 822.58 (S)
STM MH RIM 832.81
12" VCP 823.31 (N)
12" VCP 826.31 (W)
18" VCP 823.31 (S)
STM MH RIM 832.71
12" PVC 826.21 (NE)
12" RCP 824.31 (W)STM MH RIM 832.81
12" RCP 824.61 (E)
12" RCP 824.31 (S)
12" RCP 824.31 (W)
10" RCP 825.9 (NW)
12" RCP 828.21 (NW)
6" VCP 826.21 (NW)
SD SD
STM CB TOP 832.16
12" PVC 826.51 (W)
12" PVC 826.48 (N)
STM CB TOP 831.85
12" PVC 826.75 (S)
12" PVC 827.05 (N)
EMH TOP 833.39
BOT. 830.4
TOP COND. 832.2
ES
COMM MH 833.39
BOT. 825.8
BOT. T/SLAB (10") 831.1
COM MH 833.08
BOT. 826.23
BOT. T/SLAB (10") 831.1
SIXTH STREET
AP
O
LL
O
A
VE
N U
E
D O
O
LI
TT
LE
A
VE
N U
E
BUILDING 820
FFE 834.50
STM CB TOP 832.53
12" PVC 823.73 (N)
12" RCP 828.13 (W)
12" PVC 823.63 (S)
6" PVC 826.9 (S)
4" PVC 831.5 (SE)
ASPHALT DR.
CONC. DR.CONC. DR.
IPIN
N: 1019851.65 E: 2828626.33
Z: 833.17
IPIN
N: 1019798.72 E: 2828885.03 Z: 832.86
MAG NAIL
N: 1019628.39 E: 2828644.73
Z: 832.46
ASPHALT DR.
CONC.
DUMPSTER
PAD
GRASS
BLDG. 814
GRASS
CONC. WALK
GRASS
GRASS
GRASS
AS
PH
AL
T
D R
ASPHALT DRIVE
CONCRETE AIRFIELD RAMP
MAG NAIL
N: 1019655.87 E: 2828856.81
Z: 832.33BLDG. 822
BLDG. 807
CURB &
GUTTER
C U
R B
G
U
TT
ER
CURB &
GUTTER
CURB &
GUTTER
(ABAN.) STEAM MH 832.88
BOT. 826.7
BOT. T/SLAB (7") 831.4
PIV
E
EX RAMP LIGHT POLE
EX RAMP LIGHT POLE
AVIONICS B805
EXISTING
PARKING
LOT
BURIED
STRUCTURE
TO REMAIN
X
4 83
W W
EMH TOP 833.37
BOT. 828.0
BOT. T/SLAB (6") 832.3
SOIL - B-01 SOIL - B-02
SOIL - B-03
SOIL - B-04
SOIL - B-07SOIL - B-05
EXISTING LEGEND
AC UNIT
BUSH
SQUARE CATCH BASIN
CLEAN OUT
COMMUNICATION MANHOLE
GUY WIRE
DRAIN
ELECTRIC BOX
ELECTRIC METER
ELECTRIC MANHOLE
ELECTRIC/POWER POLE
FIRE HYDRANT
FINISH FLOOR ELEVATION
GAS METER
GAS VALVE
IRON PIN CONTROL POINT
LIGHT POLE
MONITORING WELL
PAYPHONE
PARKING MARKING - ACCESSIBLE
POST
SANITARY MANHOLE
SIGN
STORM MANHOLE
TREE
UTILITY MANHOLE
UTILITY VALVE
WATER VALVE
CB
CO
C
E
E
FFE
G
G
IPIN
MW
S
D
U
U
FIRE DEPARTMENT CONNECTIONFDC
ASPHALT
PIV
FDC
POST INDICATOR VALVE
FIRE DEPARTMENT CONNECTION
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
SPOT ELEVATION837.50
CONCRETE PAVEMENT
CONTRACTOR WORK LIMITS
SOIL BORING
FO FIBER OPTICS
G G GAS
E E E E UNDERGROUND ELECTRIC
ES ES ES ES ES SECONDARY UNDERGROUND ELECTRIC
X X X X FENCE
SAN SAN SANITARY SEWER
SD SD STORM DRAIN
W W W W WATER MAIN
GENERAL NOTES:
1. SURVEY BASED ON MINNESOTA STATE STATE PLANE, SOUTH ZONE, US SURVEY
FEET, NAD83(2011). VERTICAL DATUM IS NAVD88. SURVEY DATE: 8/1/2023.
2. UNDERGROUND UTILITIES WERE CAPTURED FROM RECORD DRAWINGS AND
FIELD SURVEY. ACTUAL LOCATIONS MAY VARY FROM WHAT IS SHOWN HEREON.
CONTRACTOR MUST FIELD VERIFY ANY UTILITIES THAT MAY INTERFERE WITH
ALL EXCAVATIONS.
3. CONTRACTOR SHALL VERIFY THE POSITION OF SURVEY CONTROL POINTS
PRIOR TO CONSTRUCTION ACTIVITIES AND ESTABLISH NEW CONTROL POINTS
AS REQUIRED TO MAINTAIN SURVEY CONTROL FOR THE PROJECT AND SHALL BE
BASED ON THE PRIMARY CONTROL POINTS.
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
A1 EXISTING SITE CONDITIONS
SCALE: 1" = 20'
US Army Corps of Engineers ®
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
A W
EB
ER
A W
EB
ER
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PLAN NORTH
V-101
FI
LE
:F :\3
8\
5\
2\
_C
AD
\C
IV
L\
PL
O
T\
2_ V-
1.
dw g
PL
O
T D
AT
E:
6/
/2
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
W D
AW
SE
Y
J.
R
IT
TE
R
EX
IS
TI
N G
S
IT
E C
O N
D
IT
IO
N
S
CONTRACTOR WORK LIMITS
CONTRACTOR WORK LIMITS
CONTRACTOR
STAGING
AREA
MAGNAIL MAG NAIL CONTROL POINT
TREE STUMP
E E E E ABANDONED UNDERGROUND ELECTRIC
ES ES ES ES ES ABANDONED SECONDARY
UNDERGROUND ELECTRIC
07-01-2025
W
2Q R
BA
9_
Pl an s-
US Army Corps of Engineers ®
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
A W
EB
ER
A W
EB
ER
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B-101
FI
LE
:F :\3
8\
5\
2\
_C
AD
\C
IV
L\
PL
O
T\
2_ B-
1.
dw g
PL
O
T D
AT
E:
6/
/2
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
W D
AW
SE
Y
J.
R
IT
TE
R
A1 SOIL BORING LOGS
N.T.S.
SO
IL
B O
R
IN
G L
O G
S
07-01-2025
W
2Q R
BA
9_
Pl an s-
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
A W
EB
ER
A W
EB
ER
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
B-102
FI
LE
:F :\3
8\
5\
2\
_C
AD
\C
IV
L\
PL
O
T\
2_ B-
2.
dw g
PL
O
T D
AT
E:
6/
/2
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
W D
AW
SE
Y
J.
R
IT
TE
R
A1 SOIL BORING LOGS
N.T.S.
SO
IL
B O
R
IN
G L
O G
S
07-01-2025
W
2Q R
BA
9_
Pl an s-
G
CB
CO
C I D C
I
E
D
S U
U
E
IPIN
IPIN
MAGNAIL
MAGNAIL
MAGNAIL
FFE834.50
E
FFE834.30
S
E
G
FFE834.48
E
CB
CB
D
CB
D
G G
G
G G
G G
G G
G
W W W
W W
W W
W W
W W
W W
W
E
E
G G G
W W W W W W W W W W W W W W W W W W W W W W
G G G
G
G
G
X X X X X
X
X X X X X
SD SD SD SD SD SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SAN
SAN
SAN SAN SAN SAN SAN
SA
N SAN
SAN
SAN
SAN
SAN
SANW
W
W W
W W W W W W W
W W W W W
W W W
W W
W W
W W
W W
WW
ES
ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES
E E E E E E E E E E E E E E E E E E E
E
E
E
E
E
E
E
E E
E E
W
ES ES ES ES ES ES ES ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES ES ES ES ES ES ES
FO
FO
FO FO
FO
E E
E E
E E
E E
E E
E E
E E E E E E E
FO
FO
FO
E E
E
C
C
S
SAN
SAN MH RIM 833.26
8" PVC 826.11(W)
8" PVC 826.16 (S)
6" PVC 826.86 (NE)
3" PVC 827.06 (E)
SAN MH RIM 833.85
8" PVC 827.65 (W)
8" PVC 827.65 (E)
4" PVC 827.60 (N)
SAN
SAN MH RIM 832.78
8" PVC 823.28 (E)
8" PVC 822.68 (N)
8" PVC 822.58 (S)
STM MH RIM 832.81
12" VCP 823.31 (N)
12" VCP 826.31 (W)
18" VCP 823.31 (S)
STM MH RIM 832.71
12" PVC 826.21 (NE)
12" RCP 824.31 (W)STM MH RIM 832.81
12" RCP 824.61 (E)
12" RCP 824.31 (S)
12" RCP 824.31 (W)
10" RCP 825.9 (NW)
12" RCP 828.21 (NW)
6" VCP 826.21 (NW)
SD SD
STM CB TOP 832.16
12" PVC 826.51 (W)
12" PVC 826.48 (N)
STM CB TOP 831.85
12" PVC 826.75 (S)
12" PVC 827.05 (N)
EMH TOP 833.39
BOT. 830.4
TOP COND. 832.2
ES
COMM MH 833.39
BOT. 825.8
BOT. T/SLAB (10") 831.1
COM MH 833.08
BOT. 826.23
BOT. T/SLAB (10") 831.1
SIXTH STREET
AP
O
LL
O
A
VE
N U
E
D O
O
LI
TT
LE
A
VE
N U
E
BUILDING 820
FFE 834.50
STM CB TOP 832.53
12" PVC 823.73 (N)
12" RCP 828.13 (W)
12" PVC 823.63 (S)
6" PVC 826.9 (S)
4" PVC 831.5 (SE)
ASPHALT DR.
CONC. DR.CONC. DR.
IPIN
N: 1019851.65 E: 2828626.33
Z: 833.17
IPIN
N: 1019798.72 E: 2828885.03 Z: 832.86
MAG NAIL
N: 1019628.39 E: 2828644.73
Z: 832.46
ASPHALT DR.
CONC.
DUMPSTER
PAD
GRASS
BLDG. 814
GRASS
CONC. WALK
GRASS
GRASS
GRASS
AS
PH
AL
T
D R
ASPHALT DRIVE
CONCRETE AIRFIELD RAMP
MAG NAIL
N: 1019655.87 E: 2828856.81
Z: 832.33BLDG. 822
BLDG. 807
CURB &
GUTTER
C U
R B
G
U
TT
ER
CURB &
GUTTER
CURB &
GUTTER
(ABAN.) STEAM MH 832.88
BOT. 826.7
BOT. T/SLAB (7") 831.4
PIV
E
EX RAMP LIGHT POLE
EX RAMP LIGHT POLE
AVIONICS B805
EXISTING
PARKING
LOT
BURIED
STRUCTURE
TO REMAIN
X
4 83
W W
EMH TOP 833.37
BOT. 828.0
BOT. T/SLAB (6") 832.3
SOIL - B-01 SOIL - B-02
SOIL - B-03
SOIL - B-04
SOIL - B-07SOIL - B-05
DEMO KEYNOTES
REMOVE CURB AND GUTTER
SAWCUT PAVEMENT FOR REMOVAL AND PROVIDE CLEAN EDGE
REMOVE BUILDING AND FOUNDATION
REMOVE TREE/VEGETATION
REMOVE CONCRETE
REMOVE FENCE AND SECURITY CURBING (IF APPLICABLE)
REMOVE ASPHALT
REMOVE SIDEWALK FOR NEW UTILITY INSTALLATION TO NEAREST
JOINT.
REMOVE SIDEWALK
REMOVE STORM STRUCTURE
REMOVE AND REPLACE FIBER OPTIC LINE. SEE COMMUNICATION
PLANS FOR DETAILS.
REMOVE BOLLARD
REMOVE ABANDONED UNDERGROUND ELECTRIC.
ABANDONED ELECTRIC CONDUIT TO REMAIN
REMOVE STORM DRAIN
PROTECT LIGHT/POLE DURING CONSTRUCTION
EXISTING AIR CONDITIONING TO BE PROTECTED DURING
CONSTRUCTION AND EXISTING COMPONENTS AND PAD TO BE
ADJUSTED TO GRADE
REMOVE BUILDING SIGN AND STORE FOR REINSTALLATION. SEE
C-101 FOR REINSTALLATION LOCATION.
1. ALL BOLD ITEMS ARE ASSUMED TO BE DEMO UNLESS OTHERWISE NOTED.
2. WHERE THE PLANS CALL FOR SAW CUTTING NEAT LINES ALONG THE EXISTING ASPHALT
SURFACES, THE SAW CUT SHALL BE FULL DEPTH. THE EXISTING PAVEMENT EDGE SHALL
BE SAW CUT TO LOCATE A SOUND PAVEMENT EDGE.
3. CONTRACTOR SHALL FIELD VERIFY DEPTH AND LOCATION OF ALL UNDERGROUND
UTILITIES PRIOR TO EXCAVATION AND SHALL PROTECT ALL EXISTING UTILITIES DURING
CONSTRUCTION. UTILITIES SHOWN ON THE DRAWINGS ARE BASED ON THE BEST
AVAILABLE INFORMATION AND MAY NOT REFLECT THE ACTUAL FIELD CONDITIONS OR
LOCATIONS OF UNDERGROUND STRUCTURES OR EXISTING UTILITIES. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ANY AND ALL DAMAGE TO EXISTING UTILITIES AND IS
RESPONSIBLE FOR IMMEDIATE REPAIR OF EXISTING PROJECT SITE UTILITY LINES
DAMAGED DURING CONSTRUCTION. REPAIRS SHALL BE MADE TO THE SATISFACTION
OF THE APPROPRIATE AFFECTED GOVERNMENT ENTITY OR UTILITY OWNER.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE NORMAL
OPERATING FUNCTIONS OF ALL UTILITY SYSTEMS THROUGH THE CONSTRUCTION SITE
DURING THE ENTIRE DURATION OF THE PROJECT.
5. ANY SOIL REMOVED AS PART OF THE WORK WILL NEED TO PROPERLY CHARACTERIZED
PRIOR TO DISPOSAL OFF-SITE. BORROW/DISPOSAL AREAS TO BE DETERMINED BY
CONTRACTING OFFICER.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR GROUNDS MAINTENANCE, INCLUDING
MOWING AND STANDARD HOUSEKEEPING, WITHIN THE PROJECT AREA THROUGHOUT
THE DURATION OF THE PROJECT.
7. THE CONTRACTOR SHALL MAINTAIN SITE SECURITY AND ABIDE BY ALL
MINNEAPOLIS-ST. PAUL AIR RESERVE STATION PROPERTY REGULATIONS.
8. ALL DEBRIS TO BE DISPOSED OFF-SITE.
9. SEE CS101 FOR LIMITS OF DISTURBANCE COORDINATES.
10. CONTRACTOR TO PROVIDE TEMPORARY STEEL PLATES FOR NEW UTILITY
TRENCHING ACROSS DOOLITTLE AVE UNTIL PAVEMENT IS REPLACED.
GENERAL NOTES:
DEMO LEGEND
REMOVE ASPHALT
REMOVE CONCRETE PAVEMENT
US Army Corps of Engineers ®
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
A W
EB
ER
A W
EB
ER
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PLAN NORTH
CD101
FI
LE
:F :\3
8\
5\
2\
_C
AD
\C
IV
L\
PL
O
T\
2_ C
D
1.
dw g
PL
O T
D
AT
E:
6/
/2
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
W D
AW
SE
Y
J.
R
IT
TE
R
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
A1 SITE DEMOLITION PLAN
SCALE: 1" = 20'
SI
TE
D
EM
O
LI
TI
O
N P
LA
N
7.5' 1
CONTRACTOR WORK LIMITS
CONTRACTOR WORK LIMITS
17 17
07-01-2025
W
2Q R
BA
9_
Pl an s-
CO
I
G
CB
CO
C I D C
I
E
D
S U
U
E
IPIN
IPIN
MAGNAIL
MAGNAIL
MAGNAIL
FFE834.50
E
FFE834.30
S
E
G
FFE834.48
E
CB
CB
D
W W W
W W
W W
W W
W W
W W
W
W W W W W W W W W W W W W W W W W W W W W W
X
X
X X X X X
SD SD SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SAN
SAN
SAN SAN SAN SAN SAN
SA
N SAN
SAN
SAN
SAN
SAN
SANW
W
W W
W W W W W W W
W W W W W
W W W
W W
W W
W W
W W
WW
ES
ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES
W
ES ES ES ES ES ES
ES
FO
FO
FO
FO
C
C
S
SAN
SAN
SD SD
ES
SIXTH STREET
AP
O
LL
O
A
VE
N U
E
D O
O
LI
TT
LE
A
VE
N U
E
BUILDING 820
FFE 834.50
ASPHALT DR.
IPIN
N: 1019851.65 E: 2828626.33
Z: 833.17
IPIN
N: 1019798.72 E: 2828885.03 Z: 832.86
MAG NAIL
N: 1019628.39 E: 2828644.73
Z: 832.46
CONC.
DUMPSTER
PAD
BLDG. 814
GRASS
CONC. WALK
GRASS AS
PH
AL
T
D R
ASPHALT DRIVE
CONCRETE AIRFIELD RAMP
MAG NAIL
N: 1019655.87 E: 2828856.81
Z: 832.33BLDG. 822
BLDG. 807
CURB &
GUTTER
C U
R B
G
U
TT
ER
CURB &
GUTTER
CURB &
GUTTER
PIV
EX RAMP LIGHT POLE
EX RAMP LIGHT POLE
AVIONICS B805
EXISTING
PARKING
LOT
BURIED
STRUCTURE
TO REMAIN
X
W W
SOIL - B-01 SOIL - B-02
SOIL - B-03
SOIL - B-04
SOIL - B-07SOIL - B-05
X X
X
X
X
FO
FO FO FO
U
G P
UGP UGP
U G
P
UGP UGP UGP
UGP
UGP
U G
P U
G P
U G
P
U G
P U
G P
1. ALL BOLD ITEMS ARE PROPOSED.
GENERAL NOTES:
US Army Corps of Engineers ®
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
A W
EB
ER
A W
EB
ER
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
PLAN NORTH
C-001
FI
LE
:F :\3
8\
5\
2\
_C
AD
\C
IV
L\
PL
O
T\
2_ C
-0
.d w g
PL
O T
D
AT
E:
6/
/2
Know what'sbelow Callbefore you dig.
www.call811.com
Know what'sbelow Callbefore you dig.
www.call811.com
M
IN
N
EA
PO
LI
S-
ST
P
AU
L
AI
R R
ES
ER
VE
S
TA
TI
O N
, M N
LO
U
IS
VI
LL
E
D
IS
TR
IC
T P.
O . B
O X
L
O U
IS
VI
LL
E, K Y
1-
JU
LY
C
ER
TI
FI
ED
F
IN
AL
JU
LY
C O
N
ST
R U
C T
AD
D
IT
IO
N A
N D
R
EN
O
VA
TE
A
G E
FA
C
IL
IT
Y, B
P2 : 5
W D
AW
SE
Y
J.
R
IT
TE
R
20' 40'
SCALE: 1 INCH = 20 FEET
10'20' 0'
A1 AERIAL LAYOUT PLAN
SCALE: 1" = 20'
AE
R
IA
L
LA
YO
U T
P
LA
N
CONTRACTOR WORK LIMITS
PROPOSED LEGEND
CONCRETE STOOP
(SEE DETAIL K1/S-511)
SIDEWALK
(SEE DETAIL A1/C-501)
RIVER ROCK
(SEE DETAIL D16/C-501)
ASPHALT PAVEMENT
(SEE DETAIL K16/C-501)
3" MILL AND OVERLAY
GRAVEL MOW STRIP
(SEE DETAIL A8/C-501)
07-01-2025
W
2Q R
BA
9_
Pl an s-
I
G
CB
CO
C I D C
I
E
D
S U
U
E
IPIN
IPIN
MAGNAIL
MAGNAIL
MAGNAIL
FFE834.50
E
FFE834.30
S
E
G
FFE834.48
E
CB
CB
D
W W W
W W
W W
W W
W W
W W
W
W W W W W W W W W W W W W W W W W W W W W W
X
X
X X X X X
SD SD SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SAN
SAN
SAN SAN SAN SAN SAN
SA
N SAN
SAN
SAN
SAN
SAN
SANW
W
W W
W W W W W W W
W W W W W
W W W
W W
W W
W W
W W
WW
ES
ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES
W
ES ES ES ES ES ES
ES
FO
FO
FO
FO
C
C
S
SAN
SAN
SD SD
ES
SIXTH STREET
AP
O
LL
O
A
VE
N U
E
D O
O
LI
TT
LE
A
VE
N U
E
BUILDING 820
FFE 834.50
ASPHALT DR.
IPIN
N: 1019851.65 E: 2828626.33
Z: 833.17
IPIN
N: 1019798.72 E: 2828885.03 Z: 832.86
MAG NAIL
N: 1019628.39 E: 2828644.73
Z: 832.46
CONC.
DUMPSTER
PAD
BLDG. 814
GRASS
CONC. WALK
GRASS AS
PH
AL
T
D R
ASPHALT DRIVE
CONCRETE AIRFIELD RAMP
MAG NAIL
N: 1019655.87 E: 2828856.81
Z: 832.33BLDG. 822
BLDG. 807
CURB &
GUTTER
C U
R B
G
U
TT
ER
CURB &
GUTTER
CURB &
GUTTER
PIV
EX RAMP LIGHT POLE
EX RAMP LIGHT POLE
AVIONICS B805
EXISTING
PARKING
LOT
BURIED
STRUCTURE
TO REMAIN
X
W W
SOIL - B-01 SOIL - B-02
SOIL - B-03
SOIL - B-04
SOIL - B-07SOIL - B-05
X X
X
X
X
FO
FO FO FO
U
G P
UGP UGP
U G
P
UGP UGP UGP
UGP
UGP
U G
P U
G P
U G
P
U G
P U
G P
SITE KEYNOTES
PROPOSED CURB AND GUTTER (SEE DETAIL H1/C-501)
MECHANICAL/ELECTRICAL PAD. SEE MECHANICAL, ELECTRICAL,
ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR MORE DETAILS
PROPOSED BUILDING ADDITION. FFE 834.50
PROPOSED ELECTRIC MANHOLE. SEE ES101 FOR MORE DETAILS.
C3P TYPE CONTRACTION JOINT (SEE DETAIL H1/C-502)
PROPOSED SIDEWALK (SEE DETAIL A1/C-501)
RIVER ROCK (SEE DETAIL D16/C-501)
PROPOSED CONCRETE STOOP. SEE K1/S-511 FOR MORE DETAILS.
PROPOSED 7' FABRIC SECURITY FENCE (FE6-TR-84) (SEE DETAIL
A1/C-505)
THICKENED EDGE JOINT ABUTTING K1/S-511 (SEE DETAIL F13/C-503)
PROPOSED CURB AND GUTTER TIPOUT (SEE DETAIL H6/C-501)
GRAVEL MOW STRIP (SEE DETAIL A8/C-501)
STORM STRUCTURE. SEE SHEET CG102 FOR MORE DETAILS.
CONCRETE STEPS. SEE STRUCTURAL PLANS FOR MORE DETAILS.
PROPOSED ELECTRIC CONDUIT. SEE ES101 FOR MORE DETAILS.
REPLACE CONCRETE SIDEWALK TO NEAREST JOINT (SEE DETAIL
A1/C-501)
500 GAL. ABOVE GROUND STORAGE TANK. SEE PLUMBING
DRAWINGS FOR MORE DETAILS.
CONCRETE DUMPSTER PAD (SEE DETAIL B13/C-503)
PROPOSED TELECOM. SEE TS101 FOR MORE DETAILS.
PROPOSED BOLLARD (SEE DETAIL A14/C-501)
TRANSITION CUB FROM 6" TO 0" OVER 6'. SEE CG101 FOR GRADING.
PROPOSED 6'X6' CONCRETE PAD BENEATH STORAGE TANK. SEE
STRUCTURAL PLANS FOR MORE DETAILS.
3' X 4' CONCRETE PAD FOR NEW GAS METER
TELECOM MANHOLE. SEE TS101 FOR MORE DETAILS.
REINSTALL BUILDING SIGN
EXPANSION JOINT (SEE DETAIL A1/C-502)
1. ALL BOLD ITEMS ARE PROPOSED.
2. CONSTRUCTION FENCE SHALL BE PLACED TO ALLOW FOR ACCESS TO
BUILDINGS 807 AND 830 ON THE EAST SIDE OF THE WORK ZONE. ANY CLOSURE
PERIODS FOR CONSTRUCTION NEED TO BE COORDINATED WITH THE
GOVERNMENT.
3. CONTRACTOR TO PROVIDE TEMPORARY STEEL PLATES…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .