W912QR25BA017_Plans-0002.pdf

PDF 3 MB Posted

Attached to
Construction of Rickenbacker Small Arms Range
Solicitation number
W912QR25BA017
Issued by

About this file

This document is a comprehensive Architectural Door and Window Schedule for the Ohio Air National Guard's Small Arms Range project at Rickenbacker International Airport, prepared by the U.S. Army Corps of Engineers Louisville District. The schedule details multiple exterior and interior door and window types, including specifications for materials, dimensions, glazing, fire ratings, and special requirements like bullet resistance. Key door types range from full flush and seamless designs to half-glass and vision lite doors, with frame types including hollow metal, aluminum, and CMU (concrete masonry unit) constructed for various ratings and security needs. Window specifications include thermally broken aluminum storefront windows, bullet-resistance rated windows, and fire-rated windows, with detailed glazing requirements such as blast resistance, tempered glass, and multi-layer ballistic protection. The project is marked as certified final on May 23, 2025, with a revision on August 29, 2025, and involves precise technical specifications for a specialized military facility construction project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR SCHEDULE NOTES

1. INSULATED DOOR AND FRAME.

2. EXIT ONLY DOOR.

3. BUILDING ACCESS CONTROLS.

DOOR SCHEDULE ABBREVIATIONS

AL ALUMINUM HM HOLLOW METAL

BA BRONZE ANODIZED HV HALF VIEW

BR BULLET RESISTANT IHM INSULATED HOLLOW

BRHM BULLET RESISTANT METAL

HOLLOW METAL PT PAINT

DD DOUBLE DOOR SG SINGLE DOOR

EXTR EXTERIOR SS STAINLESS STEEL

FL FLUSH SSL SINGLE SIDE LITE

FV FULL VIEW STL STEEL

INTR INTERIOR

GLAZING SCHEDULE

G1 GLAZING IS NOT REQUIRED TO BE DESIGNED OR CONSTRUCTED FOR

BLAST RESISTANCE. GLAZING ONLY INTENDED TO MINIMIZE

HAZARDOUS GLAZING FRAGMENTS. THE FOLLOWING IS A

PRESCRIPTIVE PROVISION:

1" INSULATED GLAZING UNIT TO MEET THE REQUIREMENTS OF

STANDARD 10 GLAZING UFC 4-010-01. GLASS TO BE 1/4" NOMINAL

LAMINATED GLASS CONSISTING OF TWO 1/8" NOMINAL GLASS PANES

BONDED TOGETHER WITH A MINIMUM OF A 0.030" INTERLAYER OF A

MATERIAL THAT HAS TYPICALLY BEEN USED IN DESIGNE FOR BLAST

RESISTANCE.

G2 1/4" CLEAR TEMPERED GLAZING

G3 BULLET RESISTANT RATED - UL 752 LEVELL III

1-3/16" GLAZING UNIT

THREAT SIDE

LAYER 1: 3/8" GLASS

LAYER 2: 0.03" URETHANE

LAYER 3: 3/8" GLASS

LAYER 4: 0.05" URETHANE

LAYER 5: 1/8" POLYCARBONATE

LAYER 6: 0.05" URETHANE

LAYER 7: 3/16" GLASS

SECURE SIDE

G4 2 HOUR FIRE RATED - 2-1/4" GLAZING UNIT

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR

TO PROCEEDING.

DOOR SCHEDULE NOMENCLATURE

FLUSH DOOR (DESIGN F)

THE TERM “FLUSH,” WHEN USED TO DESCRIBE A DOOR TYPE, REFERS TO A

DOOR WITHOUT LITES.

FULL FLUSH DOOR

FEATURES NO VISIBLE SEAMS ON THE SURFACE OF THE FACES. FULL

HEIGHT VERTICAL SEAMS ARE VISIBLE ON DOOR EDGES.

SEAMLESS DOOR

FEATURES NO VISIBLE SEAMS EITHER ON THE FACE OR ALONG THE

VERTICAL EDGES OF THE DOOR.

HALF GLASS DOORS (DESIGN G)

THE SIZE AND LOCATION FROM THE FINISHED FLOOR TO THE GLAZED

OPENING WILL VARY WITH THE MANUFACTURER. THEIR LITERATURE

SHOULD BE CONSULTED TO DETERMINE THIS INFORMATION AS WELL AS

RECOMMENDED GLASS SIZES. MULTIPLE LITE PATTERNS ARE CREATED BY

THE INSTALLATION OF MUNTINS.

DOORS WITH LITES ARE DESIGNED TO ACCEPT GLAZING MATERIAL OF

VARIOUS THICKNESSES.

IN ACCORDANCE WITH ANSI/ICC A117.1, DOORS CONTAINING ONE OR MORE

GLAZING PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE GLASS PANEL

A MAXIMUM OF 43" FROM THE FINISHED FLOOR.

FULL GLASS DOORS (DESIGN FG)

A MAXIMUM 7" RAIL AND STILE OCCUR AT THE TOP AND AT THE VERTICAL

EDGES OF THIS DOOR. AN 8" MINIMUM RAIL OCCURS AT THE BOTTOM.

TO COMPLY WITH ANSI/ICC A117.1 SPECIFICATION, THE BOTTOM RAIL SHALL

BE SPECIFIED AS MINIMUM 10” MEASURED VERTICALLY FROM THE FLOOR

AND SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE

FULL WIDTH OF THE DOOR. MUNTINS ARE NORMALLY USED TO CREATE THE

MULTIPLE LITE FG3 UNIT, ALTHOUGH A 5"-5 1/2" WELDED-IN RAIL IS

STANDARD WITH SOME DOOR MANUFACTURERS. CONSULT INDIVIDUAL

MANUFACTURER’S LITERATURE FOR THEIR DESIGN VARIATIONS.

VISION LITE DOOR (DESIGN V)

THE INDUSTRY STANDARD IS A 10" X 10" LITE ON THE VERTICAL CENTERLINE

OF THE DOOR. THE HORIZONTAL CENTERLINE OF THE LITE WILL VARY FROM

60" TO 66" FROM THE FINISHED FLOOR. CONSULT THE INDIVIDUAL

MANUFACTURER’S LITERATURE FOR DETAILS. THE “V” DOOR DOES NOT

COMPLY WITH ANSI/ICC A117.1. TO SATISFY THIS REQUIREMENT A NARROW

LITE (N) SHALL BE USED.

DOOR PANEL TYPES

PANEL WIDTH

SCHEDULED

S C

H E

D U

LE

D

H E

IG

H

T

A

EXTERIOR HOLLOW METAL PANEL

A INSULATED NON-RATED AB INSULATED BULLET RESISTANT

INTERIOR HOLLOW METAL PANEL

A1 NON-RATED A1B NON-RATED BULLET RESISTANT

A1R 45 MIN RATED A2BR 90 MIN RATED BULLET RESISTANT

A2R 90 MIN RATED

FLUSH - NON-RATED/RATED

PANEL WIDTH

SCHEDULED

S C

H E

D U

LE

D

H E

IG

H

T

B

INTERIOR HOLLOW METAL PANEL w/ HALF LITE

B1 NON-RATED

HALF LITE - NON-RATED

EQ. 2'-0" EQ.

3' -0

3'

-6

PANEL WIDTH

SCHEDULED

S C

H E

D U

LE

D

H E

IG

H

T

C

EXTERIOR FULL VIEW ALUMINUM PANEL

C INSULATED/NON-RATED w/ TINTED INSULATED GLAZING UNIT

INTERIOR FULL VIEW ALUMINUM PANEL

C1 NON-RATED w/ FULL VIEW TEMPERED GLAZING

FULL VIEW - NON-RATED

6"

6"

6"

T

DOOR FRAME TYPES

EXTERIOR HOLLOW METAL FRAME

A INSULATED NON-RATED AB INSULATED BULLET RESISTANT

INTERIOR HOLLOW METAL FRAME

A1 NON-RATED - GWB A2B NON-RATED BULLET RESISTANT - PC

A1R 45 MIN RATED - GWB A2BR 90 MIN RATED BULLET RESISTANT - PC

A2 NON- RATED - PRECAST A2R 90 MIN RATED - PRECAST

B

HOLLOW METAL CMU - NON-RATED/RATED

C

EXTERIOR FULL VIEW ALUMINUM PANEL

C NON-RATED w/ BLAST RESISTANT TINTED INSULATED GLAZING UNIT

ALUMINUM - SIDELITE - NON-RATED

2" [WIDTH] 2"

2" 7'

-0

A

HOLLOW METAL - NON-RATED/RATED

F R

A M

E H

E

IG

H T

'-2

[WIDTH] + 4"

FRAME WIDTH

2" [WIDTH] 2"

[WIDTH] + 4"

FRAME WIDTH

7' -0

4"

F R

A M

E H

E

IG

H T

'-4

EXTERIOR HOLLOW METAL CMU FRAME

B INSULATED NON-RATED BB INSULATED BULLET RESISTANT

INTERIOR HOLLOW METAL CMU FRAME

B1 NON-RATED B1B NON-RATED BULLET RESISTANT

B1R 45 MIN RATED B1BR 90 MIN RATED BULLET RESISTANT

PANEL WIDTH

3'-0"2" 2"

GLZ WD

1'-1 5/8"2"

3/8"FRAME WIDTH= 4'-7 5/8"3/8"

P A

N E

L H

E

IG

H T

'-0

2" 1'

-4

2"

F R

A M

E H

E

IG

H T

'-8

3/ 8"

O P

E N

IN

G

H E

IG

H

T

'-8

/8

OPENING WIDTH = 4'-8 3/8"

G

LZ

H T

1' -2

/8

1/ 8"

3/ 8"

S

ID

E

LI

G H

T H

E

IG

H T

'-7

/8

3/ 8"

1/

2"

G

LZ

H T

2'

-6

2"

G

LZ

I H T

'-1

/8 "2"

G

LZ

H T

'-4

2"

SL WD

1'-5 5/8"

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

R

IC

K E

N B

A C

K E

R

IN

T E

R N

A T

IO

N

A L

A

IR

P O

R T

A

N G

O

H

IO

O H

IO

A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E P

2# : 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

F ile

P a th

P lo t D a te

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

. . P R

O J E

C T

N O

N L

Z G

B

IM

/1 U

S A

C E

S m a ll

A rm s R a n g e r

J V

R

/1

A rc h L a n e C

F .r v t

/2

/2

:1

:3

A

M

A-621

S H

U B

E R

T

M N

O B

E R

T

G P

A R

K E

R

D M

O T

L E

Y D

O O

R S

C H

E D

U L

E

C

ER

TI

FI

ED

F

IN

AL

M A

Y

A R

C H

IT

E

C T

U R

A L

DOOR SCHEDULE - EXTERIOR

MARK DESCRIPTIION

NOMINAL PANEL FRAME

F

IR

E R

A T

IN

G

H A

R D

W A

R E

DETAILS

COMMENTS W

ID

T

E

IG

W

ID

T

T

IG

K

Y

P

P

M

T E

R

IA

L

A Z

F

IS

IG

D

P

P

T E

R

JAMB HEAD SILL

102-A 3'-0" x 7'-0" FULL VIEW ALUMINUM/GLASS STOREFRONT DOOR 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" C - AL G1 BA 4'-8" 8'-8" 2" 2" 4 1/2" C AL BA - - K1/A-623 A1/A-623 A6/A-623

A1/A-623 A6/A-623

SIDELITE 1-'2"W x 6'-10"H / TRANSOM 1'-2"W x 1'4"H & 3'-0"W x 1'-4"H, NOTE 3

102-B 3'-0" x 7'-0" FULL VIEW ALUMINUM/GLASS STOREFRONT DOOR 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" C - AL G1 BA 4'-8" 8'-8" 2" 2" 4 1/2" C AL BA - - K1/A-623 A1/A-623 A6/A-623

A1/A-623 A6/A-623

SIDELITE 1-'2"W x 6'-10"H / TRANSOM 1'-2"W x 1'4"H & 3'-0"W x 1'-4"H, NOTE 3

105-A EXTERIOR 4'-0"x7'-0" HOLLOW FLUSH METAL PANEL & CMU FRAME 4'-0" 7'-0" 4'-0" 7'-0" 1 3/4" FL - IHM - PT 4'-4" 7'-4" 2" 4" 7 3/4" B IHM PT - - K6/A-622 F6/A-622 A6/A-622

115-A EXTERIOR BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" FL - BHM - PT 3'-4" 7'-2" 2" 2" 7 3/4" AB BHM PT - - K1/A-622 F1/A-622 A1/A-622

115-B EXTERIOR BULLET RESISTANT 6'-0"x7'-0" HOLLOW METAL DOUBLE FLUSH PANEL & FRAME 6'-0" 7'-0" 3'-0" 3'-0" 7'-0" 1 3/4" AB AB BRHM - PT 6'-4" 7'-2" 2" 2" 7 3/4" AB BRHM PT - - K1/A-623 F1/A-623 A1/A-623

118-A EXTERIOR BULLET RESISTANT 6'-0"x7'-0" HOLLOW METAL DOUBLE FLUSH PANEL & FRAME 6'-0" 7'-0" 3'-0" 3'-0" 7'-0" 1 3/4" AB AB BRHM - PT 6'-4" 7'-2" 2" 2" 7 3/4" AB BRHM PT - - K1/A-623 F1/A-623 A1/A-623

118-B EXTERIOR BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" FL - BHM - PT 3'-4" 7'-2" 2" 2" 7 3/4" AB BHM PT - - K1/A-622 F1/A-622 A1/A-622

119-A EXTERIOR 4'-0"x7'-0" HOLLOW FLUSH METAL PANEL & CMU FRAME 4'-0" 7'-0" 4'-0" 7'-0" 1 3/4" FL - IHM - PT 4'-4" 7'-4" 2" 4" 7 3/4" B IHM PT - - K6/A-622 F6/A-622 A6/A-622

DOOR SCHEDULE - INTERIOR

MARK DESCRIPTIION

NOMINAL PANEL FRAME

F

IR

E R

A T

R D

W A

R E

DETAILS

COMMENTS W

ID

IG

IG

P E

M A

T E

R

A Z

IG

P

P

T E

R

JAMB HEAD SILL

106-A BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A1B BRHM - PT 3'-4" 7'-2" 2" 2" 6" A2B BRHM PT - - K11/A-622 F11/A-622 A11/A-622

106-B RATED BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & CMU FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A2BR BRHM - PT 3'-4" 7'-4" 2" 4" 6" B1BR BRHM PT 90 - K16/A-622 F16/A-622 A16/A-622

107-A RATED INTERIOR 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & CMU FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A2R HM - PT 3'-4" 7'-4" 2" 4" 6" B1R HM PT 90 - K16/A-622 F16/A-622 A16/A-622

108-A BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A1B BRHM - PT 3'-4" 7'-2" 2" 2" 6" A2B BRHM PT - - K11/A-622 F11/A-622 A11/A-622

108-B RATED BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & CMU FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A2BR BRHM - PT 3'-4" 7'-4" 2" 4" 6" B1BR BRHM PT 90 - K16/A-622 F16/A-622 A16/A-622

109-A BULLET RESISTANT 3'-0"x7'-0" HOLLOW FLUSH METAL PANEL & FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A1B BRHM - PT 3'-4" 7'-2" 2" 2" 6" A2B BRHM PT - - K11/A-622 F11/A-622 A11/A-622

111-A 3'-0"x7'-0" HOLLOW FLUSH PANEL IN HOLLOW METAL FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" B1 HM - PT 3'-4" 7'-2" 2" 2" 6" A1 HM PT - - K11/A-623 F11/A-623 A11/A-623

112-A 3'-0"x7'-0" HOLLOW FLUSH PANEL IN HOLLOW METAL FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" B1 HM - PT 3'-4" 7'-2" 2" 2" 6" A1 HM PT - - K11/A-623 F11/A-623 A11/A-623

113-A 3'-0"x7'-0" RATED HOLLOW METAL FLUSH PANEL IN RATED HOLLOW METAL FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" A1R HM - PT 3'-4" 7'-2" 2" 2" 6" A1R HM PT 45 - K11/A-623 F11/A-623 A11/A-623

114-A 3'-0"x7'-0" HOLLOW METAL HALF VIEW PANEL IN HOLLOW METAL FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" B1 HM G2 PT 3'-4" 7'-2" 2" 2" 6" A1 HM PT - - K11/A-623 F11/A-623 A11/A-623

122-A 3'-0"x7'-0" HOLLOW METAL HALF VIEW PANEL IN HOLLOW METAL FRAME 3'-0" 7'-0" 3'-0" 7'-0" 1 3/4" B1 HM G2 PT 3'-4" 7'-2" 2" 2" 6" A1 HM PT - - K11/A-623 F11/A-623 A11/A-623

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

D C

M

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

D C

M

W

2Q R

BA

7_

Pl an s-

WINDOW TYPES

W1

THERMALLY BROKEN ALUMINUM

INTERIOR BULLET RESISTANT HOLLOW METAL FRAME

W4 18'-8"W x 4'-0"H BULLET RESISTANT WINDOW

GLAZING: G3

W4

BULLET RESISTANT HOLLOW METAL

EXTERIOR THERMALLY BROKEN ALUMINUM FRAME

W1 4'-0"W x 3'-4"H WINDOW

GLAZING: G1

3" 5'-9 3/4" 4 1/2" 5'-9 1/2" 4 1/2" 5'-9 3/4" 3"

H E

A D

H E

IG

H

T

'-8

LEVEL 1

100'-0"

ACCESS FLOOR

102'-0"

107-RSO

LEVEL 1

100'-0"

FRAME WIDTH = 18'-8"

3"

3' -6

3"

2' -8

2'

-0

FRAME WIDTH

4'-0"

H E

A D

H E

IG

H

T

'-8

3" 3'

-6

3" 2'

-0

2' -8

S

IL

L H

E

IG

H T

'-8

F R

A M

E H

E

IG

H T

4' -0

3" 3'-6" 3"

INTERIOR BULLET RESISTANT HOLLOW METAL FRAME

W2 4'-0"W x 4'-0"H BULLET RESISTANT WINDOW

GLAZING: G3

W2

BULLET RESISTANT HOLLOW METAL

LEVEL 1

100'-0"

ACCESS FLOOR

102'-0"

107-RSO

FRAME WIDTH

4'-0"

1/

2" 1'

-5

/2

2"1' -4

2"

2" 3'-8" 2"

H E

IG

H

T A

T S

T O

R E

F R

O N

T

7' -0

M A

T C

H D

O O

R

S

IL

L H

E

IG

H T

'-4

F R

A M

E H

E

IG

H T

3' -4

H E

A D

H E

IG

H

T

'-8

F R

A M

E H

E

IG

H T

4' -0

S

IL

L

H E

IG

H

T

'-8

LEVEL 1

100'-0"

ACCESS FLOOR

102'-0"

107-RSO

FRAME WIDTH

4'-0"

H E

A D

H E

IG

H

T

'-8

3" 3'

-6

3"

2' -0

2'

-8

S

IL

L H

E

IG

H T

'-8

F R

A M

E H

E

IG

H T

4' -0

3" 3'-6" 3"

INTERIOR RATED ALUMINUM FRAME

W3 4'-0"W x 4'-0"H 2 HOUR FIRE RATED WINDOW

GLAZING: G4

W3

2 HOUR FIRE RATED ALUMINUM FRAME

A6

A-632

K6 A-632

A1

A-633

K1 A-633

A6

A-633

K6 A-633

K11 A-633

A11

A-633

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR

TO PROCEEDING.

GLAZING SCHEDULE

G1 GLAZING IS NOT REQUIRED TO BE DESIGNED OR CONSTRUCTED FOR

BLAST RESISTANCE. GLAZING ONLY INTENDED TO MINIMIZE

HAZARDOUS GLAZING FRAGMENTS. THE FOLLOWING IS A

PRESCRIPTIVE PROVISION:

1" INSULATED GLAZING UNIT TO MEET THE REQUIREMENTS OF

STANDARD 10 GLAZING UFC 4-010-01. GLASS TO BE 1/4" NOMINAL

LAMINATED GLASS CONSISTING OF TWO 1/8" NOMINAL GLASS PANES

BONDED TOGETHER WITH A MINIMUM OF A 0.030" INTERLAYER OF A

MATERIAL THAT HAS TYPICALLY BEEN USED IN DESIGNE FOR BLAST

RESISTANCE.

G2 1/4" CLEAR TEMPERED GLAZING

G3 BULLET RESISTANT RATED - UL 752 LEVELL III

1-3/16" GLAZING UNIT

THREAT SIDE

LAYER 1: 3/8" GLASS

LAYER 2: 0.03" URETHANE

LAYER 3: 3/8" GLASS

LAYER 4: 0.05" URETHANE

LAYER 5: 1/8" POLYCARBONATE

LAYER 6: 0.05" URETHANE

LAYER 7: 3/16" GLASS

SECURE SIDE

G4 2 HOUR FIRE RATED - 2-1/4" GLAZING UNIT

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

R

IC

K E

N B

A C

K E

R

IN

T E

R N

A T

IO

N

A L

A

IR

P O

R T

A

N G

O

H

IO

O H

IO

A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E P

2# : 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

F ile

P a th

P lo t D a te

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

. . P R

O J E

C T

N O

N L

Z G

B

IM

/1 U

S A

C E

S m a ll

A rm s R a n g e r

J V

R

/1

A rc h L a n e C

F .r v t

/2

/2

:1

:3

A

M

A-631

S H

U B

E R

T

M N

O B

E R

T

G P

A R

K E

R

D M

O T

L E

Y W

IN

D

O W

S C

H E

D U

L E

A N

D T

Y P

E S

C

ER

TI

FI

ED

F

AL

Y

A R

C H

IT

E

C T

U R

A L

WINDOW SCHEDULE - EXTERIOR

MARK DESCRIPTION

DIMENSIONS

GLAZING

TYPE

FIRE

RATING

DETAILS

COUNT COMMENTSWIDTH HEIGHT DEPTH

HEAD

HEIGHT

SILL

HEIGHT JAMB HEAD SILL

W1 THERMALLY BROKEN ALUMINUM STOREFRONT WINDOW W/ BLAST RATED TINTED INSULATED

GLAZING UNIT - 4'-0"W x 3'-4"H/8'-8" HEAD HEIGHT

4'-0" 3'-4" 4 1/2" 8'-8" 5'-4" G1 - K12/A632 A6/A632 A6/A632 6

WINDOW SCHEDULE - INTERIOR

MARK DESCRIPTION

DIMENSIONS

GLAZING

TYPE

FIRE

RATING

DETAILS

COUNT COMMENTSWIDTH HEIGHT DEPTH

HEAD

HEIGHT

SILL

HEIGHT JAMB HEAD SILL

W2 BULLET RESISTANT HOLLOW METAL WINDOW W/ BALLISTIC GLAZING UNIT - 4'-0"W x 4'-0"H/8'-8" HEAD

HEIGHT

4'-0" 4'-0" 4 7/8" 8'-8" 4'-8" G3 - K1/A-633 A1/A-633 A1/A-633 2

W3 ALUMINUM WINDOW 2-HOUR RATED - 4'-0"W x 4'-0"H - 8'-8" HEAD HEIGHT 4'-0" 4'-0" 6" 8'-8" 5'-4" G4 2HR K6/A-633 A6/A-633 A6/A-633 1

W4 BULLET RESISTANT HOLLOW METAL TRIPLE PANE WINDOW W/ BALLISTIC GLAZING UNIT - 18'-8"W x

4'-0"H/8'-8" HEAD HEIGHT

18'-8" 4'-0" 4 7/8" 8'-8" 4'-8" G3 - K11/A-63

A11/A-63

A11/A-63

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

C

E R

T

IF

IE

D

F

IN

A L

D C

M

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

D C

M

W

2Q R

BA

7_

Pl an s-

SAW CUT

SAW CUT

FILTER TUBE /

SOCK FILTER DAM

FILTER TUBE /

SOCK SEDIMENT CONTROL

EXIST. STORM HEADWALL

TO REMAIN

FH

D

D

S

FH

S

H

S

MW

C

C

J

FH

C

E

E

E

E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E

BLOCK BUILDING

FL=736.75

STORM INLET

RIM=739.84

ENE 8" CHDPE=737.24

STORM INLET

RIM=739.76

SW 8" CHDPE=737.06

NW 10" CHDPE=736.91

STORM INLET

RIM=739.93

SE 10" CHDPE=736.83

NW 12" CHDPE=736.68

STORM INLET

RIM=739.58

SE 12" CHDPE=735.68

NW 12" CHDPE=735.63

STORM INLET

RIM=739.88

NE 8" CHDPE=737.38

SE 12" CHDPE=735.46

SW 15" CHDPE=735.18

STORM INLET

RIM=739.91

ENE 15" CHDPE=734.86

SW 15" CHDPE=734.81

STORM MANHOLE

RIM=741.55

E 15" CHDPE=734.30

NW 15" CHDPE=734.23

STORM VAULT

RIM=739.23

NE 60" RCP=726.13

SW 60" RCP=726.13

STORM INLET

RIM=739.23

NE 60" RCP=725.15

SE 8" VCP=733.87

SW 15" CHDPE=725.15

STORM INLET

RIM=739.30

SE 12" RCP=733.60

NW 18" RCP=730.30

STORM INLET

RIM=739.49

SE 12" RCP=733.39

SW 8" VCP=732.04

NW 18" RCP=730.39

SANITARY MANHOLE

RIM=740.12

NE 15" PVC=732.55

SE 8" PVC=733.16

SW 8" PVC =732.72

NW 8" PVC=736.58

SANITARY MANHOLE

RIM=740.29

NE 15" PVC=731.84

SW 15" PVC=731.64

MANHOLE

RIM=738.39

FULL OF WATER

BOTTOM=734.7

WATER MANHOLE

RIM=743.66

BOTTOM=736.3

FL CMP=736.90

FILLED WITH SILT

APPROXIMATE

LOCATION PER

SURFACE

EVIDENCE

FL 18" RCP=734.88

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SDSDSDSDSD

SDSDSDSDSD

COMMUNICATION MANHOLE

RIM=742.11

COMMUNICATION MANHOLE

RIM=739.41

TR

EN

C H

SC

AR

U N

KN

O

W N

U

TILITY

W W W

W W

W

W W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

WWWWWWWWW

W

WWWW

W W

W W

COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM

ELECTRICAL EQUIPMENT

POWER POLE W/ DROP

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

GRAVEL

6' WOOD

PRIVACY FENCE

CONCRETE

DUMPSTER PAD

G

AT

E

HAND HOLE - LIGHTING?

COVERED RR TRACKS

W W

W W

W W

W W

W W

W W

W

F

FFFFFFFFFFF

F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F

FFFFF

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN

MINUTEMAN WAY

ZISTEL ST.

(ASPHALT)

(ASPHALT)

(ASPHALT)

(CONC)

(CONC)

CONTROL POINT #2

CONTROL POINT #3

CONTROL POINT #4

CONTROL POINT #1

6' C

H

AI

N L

IN

K

FE

N

C E

W

IT

H B

AR

BE

D W

IR

E

740 740

736 737

(A

SP

H

AL

T)

(ASPHALT)

(GRASS)

(GRASS)

(GRASS)

(GRASS)

(GRASS)

NO VISIBLE EVIDENCE OF

TERMINUS(TYP.)

CENTERLINE DITCH

E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E

E E

E E

ELECTRIC LINE IS APPROXIMATE

FIELD VERIFY

SD SD SD SD SD SD SD SD SD SD SD SD SD

APPROXIMATE

LOCATION 60" RCP

D

EM

O

LI

TI

O

N A

N D

E R

O

SI

O N

C-101

J

PO

LL

M

AN

J

BE

AN

R P

EA

R

SO

N

D M

O

TL

EY

C

ER

TI

FI

ED

F

AY

3, M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N

LZ

G

C

ER

TI

FI

ED

F

IN

AL

D

C M

SHEET ID

D

ES

IG

N

B Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

SU

BM

IT

TE

D B

Y:

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R M

AR

TI

N L

U

TH

ER

J

R P

L

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

A

RI

CK

EN

BA

CK

ER

IN

TE

RN

AT

IO

NA

L A

IR

PO

RT

(A

NG

OH

IO

OH

IO

A

IR

N

AT

IO

NA

L G

UA

RD

AN

G

SM

AL

L A

RM

S

RA

NG

E

P 2#

CI

VI

L

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

Fi le

P at h:

Pl ot D at e:

US Army Corps of Engineers ®

IS

SU

E D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

SI

ZE

AN

SI

D

. . PR

O

JE

C

T N

O

NOTES:

1. REFER TO SHEET NO. C-002 FOR GENERAL

NOTES .

2. REFER TO SHEET NO. C-003 FOR SITE LEGEND.

KEYNOTES:

PROPOSED SMALL ARMS BUILDING.

WASHOUT. SEE SHEET C-512.

LAYDOWN AREA.

SAW CUT EXISTING ASPHALT PAVEMENT MINIMUM

2'-0" INSIDE EXISTING EDGE OF PAVEMENT AND

REMOVE EXISTING ASPHALT PAVEMENT TO FULL

DEPTH SOUTH OF SAW CUT LINE.

SILT FENCE. SEE SHEET C-513

FILTER SOCK. SEE DETAIL C-514.

REMOVE FIRE HYDRANT, VALVE AND PIPE.

C O

N

TR

O L

6 6

REMOVE

63 LF WATER LINE

1-GATE VALVE

1-FIRE HYDRANT

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

D

C M

W

2Q R

BA

7_

Pl an s-

HH

TO SECURITY FORCES B876 (BUILING

155) VIA EXISTING MANHOLE AND

DUCTBANK SYSTEM

(2) 4" CONDUITS

KEYED PLAN

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

R

IC

K E

N B

A C

K E

R

IN

T E

R N

A T

IO

N

A L

A

IR

P O

R T

A

N G

O

H

IO

O H

IO

A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E P

2# : 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

F ile

P a th

P lo t D a te

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

. . P R

O J E

C T

N O

N L

Z G

B

IM

/1 U

S A

C E

S m a ll

A rm s R a n g e r

J V

R

/1

T e c h L a n e C

F .r v t

/2

/2

:2

:3

P

M

T-100

N M

A P

L E

S

J H

O U

L

IH

A N

A P

IL

L A

I

D M

O T

L E

Y T

E

LE

C O

M S

IT

E

P

LA

N

C

ER

TI

FI

ED

F

U G

T E

LE

C

O M

M U

N

IC

A T

IO

N

S

3/32" = 1'-0" C1

FIRST FLOOR TELECOM PLAN - SITEFIRST FLOOR TELECOM PLAN - SITE

KEYED NOTES (THIS SHEET ONLY)

1. TWO (2) FOUR-INCH CONDUITS INSTALLED UNDERGROUND FROM

EXISTING SECURITY FORCES B876 TO ELECTRICAL ROOM 119 (APPROX.

100 LINEAR FEET). EACH CONDUIT WILL HAVE TWO TRI-CELL MESH

INNERDUCT FOR FIBEROPTIC CABLE (24-STRAND SMFO), COPPER CABLE

(25 PAIR CATEGORY 3), AND FUTURE SPARE. SEE DETAIL K11 / T-501.

2. NEW COMMUNICATIONS HANDHOLE. SEE DETAIL G1 / T-501.

3. TWO (2) FOUR-INCH OSP CONDUIT PENETRATIONS. STUB UP CONDUITS

6" AFF.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

D C

M

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 3/32" = 1'-0"

8' 4' 0' 8' 24'16'

W

2Q R

BA

7_

Pl an s-

Architectural
A-621 - DOOR SCHEDULE
A-631 - WINDOW SCHEDULE AND TYPES
C-101 Demo and Erosion Control
T-100 Telecom Site Plan

File details come from the government source that posted it. Updated .