W912QR25BA017_Plans-0000.pdf
PDF 44 MB Posted
- Attached to
- Construction of Rickenbacker Small Arms Range
- Solicitation number
- W912QR25BA017
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME: SHEET ID
D E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
P R
O J E
C T
N O
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
N L
Z G
VOLUME 1 OF 1
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
A rc h L a n e C
F .r v t
/2
/2
:0
:5
A
M
LOUISVILLE DISTRICT
RICKENBACKER INTERNATIONAL AIRPORT (ANG), OHIO
OHIO AIR NATIONAL GUARD
P2# 508679
ANG SMALL ARMS RANGE
CERTIFIED FINAL G-001
S H
U B
E R
T
M N
O B
E R
T
G P
A R
K E
R
D M
O T
L E
Y
C E
R T
IF
IE
D F
IN
A
L
MAY 23, 2025
M A
Y
C O
V E
R S
H E
E T
G E
N E
R A
L
CIVIL STRUCTURAL ARCHITECTURAL / INTERIORS
FIRE PROTECTION PLUMBING / MECHANICAL ELECTRICAL
TELECOMMUNICATIONS /
LOW VOLTAGE
A / E PROFESSIONAL STAMPS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
04 August 2025
W912QR25BA017
SHEET ID
D E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
A rc h L a n e C
F .r v t
/2
/2
:0
:5
A
M
G-002
S H
U B
E R
T
M N
O B
E R
T
G P
A R
K E
R
D M
O T
L E
Y
IN
D E
X O
F D
R A
W
IN
G S
C E
R T
IF
IE
D F
IN
A
L
M A
Y
G E
N E
R A
L
SHEET
NUMBER SHEET NAME REV DATE
FIRE PROTECTION
FA001 FIRE ALARM LEGEND AND NOTES 0 20250523
FA110 FIRE ALARM PLAN - COMPOSITE 0 20250523
FA600 FIRE ALARM / MASS NOTIFICATION SYSTEM RISER DIAGRAM 0 20250523
FA601 FIRE ALARM / MASS NOTIFICATION SYSTEM ACTION MATRIX 0 20250523
FA602 FIRE ALARM/ MASS NOTIFICATION SYSTEM AUDIBLE AND VISUAL MESSAGES 0 20250523
FIRE PROTECTION: 5
Grand total: 149
SHEET
NUMBER SHEET NAME REV DATE
ARCHITECTURAL
A-001 PROJECT RENDERINGS 0 20250523
A-002 PROJECT RENDERINGS 0 20250523
A-003 GENERAL PROJECT NOTES 0 20250523
A-004 ABBREVIATIONS 0 20250523
A-005 LEGENDS 0 20250523
A-006 LEGENDS 0 20250523
A-011 ACCESSIBILITY - FIRST FLOOR PLAN 0 20250523
A-012 ACCESSIBILTY - REQUIREMENTS 0 20250523
A-013 ACCESSIBILTY - REQUIREMENTS 0 20250523
A-021 AIR BARRIER - FIRST FLOOR PLAN 0 20250523
A-022 AIR BARRIER - BUILDING SECTIONS 0 20250523
A-023 AIR BARRIER - WALL SECTIONS 0 20250523
A-031 UL ASSEMBLIES - FIRST FLOOR PLAN 0 20250523
A-032 UL ASSEMBLIES - U905 0 20250523
A-033 UL ASSEMBLIES - U419 0 20250523
A-034 UL ASSEMBLIES - U419 0 20250523
A-035 UL ASSEMBLIES - U419 0 20250523
A-036 UL ASSEMBLIES - H505 0 20250523
A-041 DOWNSPOUTS AND GUTTER - ROOF PLAN 0 20250523
A-042 DOWNSPOUT AND GUTTER SIZING REPORTS 0 20250523
A-091 BUILDING AREA TABULATION - FIRST FLOOR PLAN 0 20250523
A-110 FIRST FLOOR PLAN - COMPOSITE 0 20250523
A-111 FIRST FLOOR PLAN - MCSATS 0 20250523
A-112 FIRST FLOOR PLAN - CATM 0 20250523
A-120 ROOF PLAN - COMPOSITE 0 20250523
A-121 ROOF PLAN - MCSATS 0 20250523
A-122 ROOF PLAN - CATM 0 20250523
A-201 BUILDING ELEVATIONS 0 20250523
A-301 BUILDING SECTIONS 0 20250523
A-311 WALL SECTIONS 0 20250523
A-312 WALL SECTIONS 0 20250523
A-313 WALL SECTIONS 0 20250523
A-314 WALL SECTIONS 0 20250523
A-401 110-WEAPONS MX PLANS AND ELEVATIONS 0 20250523
A-402 107-RSO PLANS AND ELEVATIONS 0 20250523
A-403 TOILET ROOMS PLANS AND ELEVATIONS 0 20250523
A-404 ENLARGED PLANS AND ELEVATIONS 0 20250523
A-501 DETAILS 0 20250523
A-502 DETAILS 0 20250523
A-503 DETAILS 0 20250523
A-504 DETAILS 0 20250523
A-505 DETAILS 0 20250523
A-506 DETAILS 0 20250523
A-507 DETAILS 0 20250523
A-508 DETAILS 0 20250523
A-601 PRECAST WALL TYPES 0 20250523
A-602 PRECAST WALL TYPES 0 20250523
A-603 PRECAST WALL TYPES 0 20250523
A-611 PARTITION TYPES 0 20250523
A-612 PARTITION TYPES 0 20250523
A-621 DOOR SCHEDULE 0 20250523
A-622 DOOR DETAILS 0 20250523
A-623 DOOR DETAILS 0 20250523
A-631 WINDOW SCHEDULE AND TYPES 0 20250523
A-632 EXTERIOR WINDOW DETAILS 0 20250523
A-633 INTERIOR WINDOW DETAILS 0 20250523
A-710 FIRST FLOOR REFLECTED CEILING PLAN 0 20250523
A-711 FIRST FLOOR REFLECTED CEILING PLAN - MCSATS 0 20250523
A-712 FIRST FLOOR REFLECTED CEILING PLAN - CATM 0 20250523
ARCHITECTURAL: 59
INTERIORS
I-111 FIRST FLOOR FINISH PLAN - SECTOR 1 0 20250523
I-112 FIRST FLOOR FINISH PLAN - SECTOR 2 0 20250523
I-151 FIRST FLOOR PATTERN PLAN - SECTOR 1 0 20250523
I-152 FIRST FLOOR PATTERN PLAN - SECTOR 2 0 20250523
I-400 ENLARGED PLANS & ELEVATIONS 0 20250523
I-401 ENLARGED PLANS & ELEVATIONS 0 20250523
IF111 FIRST FLOOR FURNITURE PLAN - SECTOR 1 0 20250523
IF112 FIRST FLOOR FURNITURE PLAN - SECTOR 2 0 20250523
IG111 FIRST FLOOR SIGNAGE PLAN - SECTOR 1 0 20250523
IG112 FIRST FLOOR SIGNAGE PLAN - SECTOR 2 0 20250523
IG531 SIGNAGE DETAILS 0 20250523
IG532 SIGNAGE DETAILS AND SCHEDULE 0 20250523
IN601 ROOM FINISH SCHEDULE AND MATERIALS & FINISH LEGEND 0 20250523
INTERIORS: 13
SHEET
NUMBER SHEET NAME REV DATE
GENERAL
G-001 COVER SHEET 0 20250523
G-002 INDEX OF DRAWINGS 0 20250523
G-003 INDEX OF DRAWINGS 0 20250523
GENERAL: 3
LIFE SAFETY
GI001 LIFE SAFETY CODE ANALYSIS 0 20250523
GI002 FPLS FORM 0 20250523
GI003 FPLS FORM CONT. 0 20250523
GI010 CODE COMPLIANCE SITE PLAN 0 20250523
GI110 LIFE SAFETY PLAN - COMPOSITE 0 20250523
LIFE SAFETY: 5
CIVIL
C-001 VICINITY MAP 0 20250515
C-002 GENERAL NOTES 0 20250515
C-003 CIVIL ABBREVIATIONS AND SYMBOLS 0 20250515
C-004 SITE PHOTOS 0 20250515
C-005 DESIGN CONCEPT PLAN 0 20250515
VF101 TOPOGRAPHIC SURVEY 0 20250515
C-101 DEMOLITION AND EROSION CONTROL 0 20250515
C-102 SITE PLAN 0 20250515
C-103 COORDINATE LAYOUT POINTS 0 20250515
C-104 GRADING AND STORM DRAINAGE PLAN 0 20250515
C-105 UTILITY PLAN 0 20250515
C-106 SANITARY SEWER PLAN AND PROFILE 0 20250515
CS151 COORDINATE TABLES 0 20250515
CP401 DRIVE LAYOUTS 0 20250515
BB-101 BORING LOCATION MAP 0 20250515
BB-102 BORING SPECIFICATIONS 0 20250515
C-501 SANITARY SEWER DETAILS - SHEET 1 0 20250515
C-502 SANITARY SEWER DETAILS - SHEET 2 0 20250515
C-503 STORM SEWER DETAILS 0 20250515
C-504 WATERLINE DETAILS 0 20250515
C-505 PAVING DETAILS - SHEET 1 0 20250515
C-506 PAVING DETAILS - SHEET 2 0 20250515
C-507 ACCESS CONTROL GATE DETAILS 0 20250515
C-508 BOLLARD DETAILS 0 20250515
C-509 ADA ACCESS DETAILS 0 20250515
C-510 SIGNING AND MARKING DETAILS 0 20250515
C-511 EROSION CONTROL DETAILS - SHEET 1 0 20250515
C-512 EROSION CONTROL DETAILS - SHEET 2 0 20250515
C-513 EROSION CONTROL DETAILS - SHEET 3 0 20250515
C-514 EROSION CONTROL DETAILS - SHEET 4 0 20250515
C-515 ROOF DRAIN DETAILS 0 20250515
C-516 FENCE DETAILS 0 20250515
C-517 GATE DETAILS 0 20250515
C-518 TEMPORARY SECURITY CONSTRUCTION FENCE DETAILS 0 20250515
C-519 TEMPORARY SECURITY CONSTRUCTION GATE DETAILS 0 20250515
CIVIL: 35
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES 0 20250523
S-002 GENERAL STRUCTURAL NOTES 0 20250523
S-003 GENERAL STRUCTURAL NOTES 0 20250523
S-004 GENERAL STRUCTURAL NOTES 0 20250523
S-005 STRUCTURAL ABBREVIATIONS AND SYMBOLS 0 20250523
S-010 TYPICAL DETAILS - CONCRETE SLAB-ON-GRADE 0 20250523
S-011 TYPICAL DETAILS - CONCRETE 0 20250523
S-012 TYPICAL DETAILS - CONCRETE MASONRY 0 20250523
S-013 TYPICAL DETAILS - STEEL FRAMING 0 20250523
S-014 TYPICAL DETAILS - CFMF TRUSS PROFILES 0 20250523
S-020 COMPONENTS AND CLADDING (C&C) - WIND PRESSURE DIAGRAMS 0 20250523
S-110 OVERALL FOUNDATION PLAN 0 20250523
S-111 FOUNDATION PLAN - MCSATS 0 20250523
S-112 FOUNDATION PLAN - CATM 0 20250523
S-121 INTERMEDIATE FRAMING PLAN - MCSATS 0 20250523
S-130 OVERALL ROOF FRAMING PLAN 0 20250523
S-131 ROOF FRAMING PLAN - MCSATS 0 20250523
S-132 ROOF FRAMING PLAN - CATM 0 20250523
S-200 WALL ELEVATIONS 0 20250523
S-201 WALL ELEVATIONS 0 20250523
S-202 WALL ELEVATIONS 0 20250523
S-203 WALL ELEVATIONS 0 20250523
S-400 ENLARGED FOUNDATION PLAN - MECHANICAL YARD 0 20250523
S-401 ENLARGED FRAMING PLAN 0 20250523
S-500 FOUNDATION SECTIONS AND DETAILS 0 20250523
S-501 FOUNDATION SECTIONS AND DETAILS 0 20250523
S-510 FRAMING SECTIONS AND DETAILS 0 20250523
S-511 FRAMING SECTIONS AND DETAILS 0 20250523
S-900 ISOMETRIC VIEWS 0 20250523
STRUCTURAL: 29
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
A rc h L a n e C
F .r v t
/2
/2
:0
:5
A
M
G-003
S H
U B
E R
T
M N
O B
E R
T
G P
A R
K E
R
D M
O T
L E
Y
IN
D E
X O
F D
R A
W
IN
G S
C E
R T
IF
IE
D F
IN
A
L
M A
Y
G E
N E
R A
L
SHEET
NUMBER SHEET NAME REV DATE
AUDIO VISUAL
TA111 FIRST FLOOR PLAN AV PLAN - SECTOR 1 0 20250523
TA112 FIRST FLOR PLAN AV PLAN - SECTOR 2 0 20250523
TA114 FIRST FLOOR AV RCP - SECTOR 2 0 20250523
TA401 ENLARGED AV ROOM 114 PLANS 0 20250523
TA501 AV DETAILS 0 20250523
TA502 AV DETAILS 0 20250523
TA601A AV SINGLE LINE DIAGRAMS - CLASSROOM 114 0 20250523
TA601B AV SINGLE LINE DIAGRAMS - ELECTRICAL 119 0 20250523
TA601C AV SINGLE LINE DIAGRAMS - CLASSROOM 114 0 20250523
TA602A AV SINGLE LINE DIAGRAMS - TYPICAL DIAGRAMS 0 20250523
TA801 AV EQUIPMENT SCHEDULE 0 20250523
AUDIO VISUAL: 11
SECURITY
TY000 SECURITY SYMBOLS & ABBREVIATIONS 0 20250523
TY111 FIRST FLOOR SECURITY PLAN - SECTOR 1 0 20250523
TY112 FIRST FLOOR SECURITY PLAN - SECTOR 2 0 20250523
TY500 ACS DETAILS 0 20250523
TY501 ACS DETAILS 0 20250523
TY502 ACS DETAILS 0 20250523
TY503 ACS DETAILS 0 20250523
TY504 CAMERA DETAILS 0 20250523
SECURITY: 8
Grand total: 81
SHEET
NUMBER SHEET NAME REV DATE
PLUMBING
P-001 LEGEND AND ABBREVATIONS 0 20250523
P-100 SANITARY & VENT - UNDERGROUND - COMPOSITE 0 20250523
P-102 SANITARY & VENT - UNDERGROUND - CATM 0 20250523
P-110 SANITARY & VENT - LEVEL 1 - COMPOSITE 0 20250523
P-112 SANITARY & VENT - LEVEL 1 - CATM 0 20250523
P-210 DOMESTIC WATER - LEVEL 1 - COMPOSITE 0 20250523
P-212 DOMESTIC WATER - LEVEL 1 - CATM 0 20250523
P-220 NATURAL GAS - LEVEL 1 - COMPOSITE 0 20250523
P-222 NATURAL GAS - LEVEL 1 - CATM 0 20250523
P-232 ROOF PLAN - CATM 0 20250523
P-501 PLUMBING DETAILS 0 20250523
P-601 PLUMBING SCHEDULES 0 20250523
P-901 WASTE AND VENT ISOMETRIC 0 20250523
P-902 DOMESTIC WATER ISOMETRIC 0 20250523
PLUMBING: 14
MECHANICAL
M-001 LEGEND AND ABBREVIATIONS 0 20250523
M-002 BASIS OF DESIGN / GENERAL NOTES 0 20250523
M-110 HVAC FIRST FLOOR PLAN - COMPOSITE 0 20250523
M-111 HVAC FIRST FLOOR PLAN - MCSATS 0 20250523
M-112 HVAC FIRST FLOOR PLAN - CATM 0 20250523
M-201 SECTION VIEW 0 20250523
M-401 AIR BALANCE DIAGRAM 0 20250523
M-501 DETAILS 0 20250523
M-502 DETAILS 0 20250523
M-503 DETAILS 0 20250523
M-601 SCHEDULES 0 20250523
M-602 SCHEDULES 0 20250523
M-701 CONTROLS GENERAL NOTES 0 20250523
M-702 POINT SCHEDULE FOR BUILDING CONTROLS INSTRUCTIONS 0 20250523
M-703 DDC SYSTEM ARCHITECTURE 0 20250523
M-704 CONTROL DIAGRAM - RANGE VENTILATION SYSTEM 0 20250523
M-705 CONTROL DIAGRAM - RANGE VENTILATION CONTROL DEVICE LOCATIONS 0 20250523
M-706 CONTROL DIAGRAM - ENERGY RECOVERY VENTILATOR 0 20250523
M-707 CONTROL DIAGRAM - AIR CONDITIONING UNITS 0 20250523
M-708 CONTROL DIAGRAM - MINI SPLIT AIR CONDITIONING UNIT 0 20250523
M-709 UTILITY METERING CONTROLS 0 20250523
MECHANICAL: 21
ELECTRICAL
E-001 LEGEND AND ABBREVIATIONS 0 20250515
ES101 ELECTRICAL SITE PLAN 0 20250515
EG110 GROUNDING PLAN 0 20250515
EG501 GROUNDING DETAILS 0 20250515
EP111 POWER PLAN 0 20250515
EQ111 EQUIPMENT POWER PLAN 0 20250515
EQ601 MECHANICAL EQUIPMENT ELECTRICAL CONNECTIONS 0 20250515
EL001 LIGHTING LEGEND AND SCHEDULES 0 20250515
EL111 LIGHTING PLAN 0 20250515
EL211 LIGHTING CONTROL PLAN 0 20250515
EL212 LIGHTING CONTROL SCHEDULES AND DIAGRAMS 0 20250515
EL501 LIGHTING FIXTURE DETAIL 0 20250515
EL502 LIGHTING FIXTURE DETAIL 0 20250515
E-600 ONE-LINE LEGEND 0 20250515
E-601 ELECTRICAL ONE-LINE DIAGRAM 0 20250515
E-602 PANEL SCHEDULES 0 20250515
E-603 PANEL SCHEDULES 0 20250515
ELECTRICAL: 17
TELECOMMUNICATIONS
T-000 TELECOM GENERAL NOTES, SYMBOLS & ABBREVIATIONS 0 20250523
T-100 TELECOM SITE PLAN 0 20250523
T-110 FIRST FLOOR TELECOM PLAN 0 20250523
T-111 FIRST FLOOR TELECOM PLAN - SECTOR 1 0 20250523
T-112 FIRST FLOOR TELECOM PLAN - SECTOR 2 0 20250523
T-400 ENLARGED TELECOM ROOM PLANS & RACK ELEVATIONS 0 20250523
T-500 TELECOM DETAILS 0 20250523
T-501 TELECOM DETAILS 0 20250523
T-502 TELECOM DETAILS 0 20250523
T-600 TELECOM WIRING DIAGRAM 0 20250523
TELECOMMUNICATIONS: 10
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
F ir e L a n e C
F .r v t
/1
/2
:1
:3
A
M
GI001
C
E N
N
IS
K
C L A
Y
N
S A
N M
A N
N
D
M O
T L E
Y
LI
F E
S A
F E
T Y
C O
D E
A N
A L
Y S
IS
C E
R T
IF
IE
D F
IN
A
L
M
AY
3, G E
N E
R A
L
APPLICABLE CODES AND STANDARDS
• ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS FOR DOD FACILITIES, 2015
• 2021 INTERNATIONAL BUILDING CODE (IBC), AS AMENDED BY UFC 1-200-01
• ENGINEERING AND CONSTRUCTION BULLETIN (ECB) NO. 2018-17, NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS
NOTIFICATION SYSTEMS, REV. 2, JANUARY 20, 2022.
• NFPA 1, FIRE CODE, 2021
• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2022
• NFPA 24, INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2022
• NFPA 70, NATIONAL ELECTRICAL CODE, 2023
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022
• NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2022
• NFPA 101, LIFE SAFETY CODE, 2021
• NFPA 221, STANDARD FOR HIGH CHALLENGE FIRE WALLS, FIRE WALLS, AND FIRE BARRIER WALLS, 2021
• NFPA 291, RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2022
• NFPA 400, HAZARDOUS MATERIALS CODE, 2019
• UFC 1-200-01, DOD BUILDING CODE, CHANGE 2, JUNE 2023
• UFC 3-420-01, PLUMBING SYSTEMS, APRIL 1, 2021
• UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, CHANGE 2, APRIL 12, 2021
• UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021
• UFC 4-010-01, DOD MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDINGS, CHANGE 2, JULY 30, 2022
• UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE 1, JANUARY 2010
• UFC 4-179-02, SMALL ARMS RANGES, MARCH 2020
UFC 3-600-01 SUPPLEMENTS THE REQUIREMENTS LISTED IN UFC 1-200-01. UFC 3-600-01 SUPERSEDES NFPA AND OTHER INDUSTRY STANDARDS WHERE THERE IS A CONFLICT, EXCEPT WHERE NOT SPECIFICALLY ADDRESSED BY UFC 3-600-01. (UFC 3-600-01 §1-4.2.1) WHERE THE IBC REFERENCES THE INTERNATIONAL FIRE CODE, (IFC), THE IFC MUST BE REPLACED WITH NFPA 1, EXCEPT WHERE
SUPERSEDED BY UFC 3-600-01 (UFC 3-600-01 §1-4.2.3).
HAZARDOUS MATERIALS
THE ARMS RANGE BUILDING CONTAINS A MATERIAL LABELED SYNTHETIC CLP GUN OIL, CLASSIFIED AS A COMBUSTIBLE LIQUID CLASS IIIB AND WILL BE LIMITED TO 10 PINTS, WHICH IS BELOW THE 13,200 GALLONS PERMITTED WITHIN THE FACILITY. THE QUANTITIES OF HAZARDOUS MATERIALS ARE SIGNIFICANTLY BELOW THE MAXIMUM ALLOWABLE QUANTITIES (MAQ) PERMITTED IN NFPA 400 TABLE
5.2.1.1.3 FOR A NONSPRINKLERED BUILDING.
OCCUPANCY CLASSIFICATION
THE BUILDING OCCUPANCY CLASSIFICATION FOR COMPLIANCE WITH BUILDING CODE REQUIREMENTS SUCH AS CONSTRUCTION TYPE, ALLOWABLE HEIGHT AND AREA, BUILDING SEPARATION DISTANCE, OCCUPANCY SEPARATION AND ASSOCIATED REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE IBC (UFC 3-600-01 §3-2.1.2). THE BUILDING OCCUPANCY CLASSIFICATION FOR COMPLIANCE WITH FIRE/SMOKE RESISTANCE RATING OF INTERIOR NON-LOAD BEARING PARTITIONS (OTHER THAN OCCUPANCY SEPARATION), MEANS OF EGRESS, INTERIOR FINISH, FEATURES OF FIRE PROTECTION (VERTICAL OPENINGS) AND ASSOCIATED REQUIREMENTS SHALL BE IN
ACCORDANCE WITH NFPA 101 (UFC 3-600-01 §3-3.1.1).
THE ARMS RANGE BUILDING IS A NON-SEPARATED, MIXED-USE BUILDING CONSISTING OF BUSINESS GROUP “B” AND MODERATE
HAZARD FACTORY INDUSTRIAL “F-1” (IBC §508.3 AND NFPA 101 §6.1.14.2.1).
THE OCCUPANCIES INVOLVED ARE AS FOLLOWS:
• BUSINESS GROUP “B” CLASSROOM PER IBC §304.1.
• MODERATE-HAZARD FACTORY INDUSTRIAL GROUP “F-1” CONSISTING OF RANGE BAY, SUPPORT SPACES, AND EQUIPMENT
STORAGE PER IBC §306.1.
• NEW BUSINESS GROUP “B” CONSISTING OF OFFICES, AND ADMINISTRATIVE AREAS NFPA 101 §6.1.11.1.
• INDUSTRIAL CONSISTING OF RANGE BAY, SUPPORT SPACES, AND EQUIPMENT STORAGE PER NFPA 101 §6.1.12.1.
**PER NFPA 101, A MIXED OCCUPANCY BUILDING IS WHEN DIFFERENT OCCUPANCY TYPES ARE INTERMINGLED WITHOUT FIRE-RATED SEPARATION. FOR MIXED OCCUPANCIES, THE BUILDING SHALL COMPLY WITH THE MOST RESTRICTIVE REQUIREMENTS OF THE
OCCUPANCIES INVOLVED, UNLESS SEPARATE SAFEGUARDS ARE APPROVED.
CONSTRUCTION TYPE
THE ARMS RANGE BUILDING IS A ONE-STORY STRUCTURE OF NON-FIRE-RESISTANCE RATED, NON-COMBUSTIBLE CONSTRUCTION WITH
A CONSTRUCTION CLASSIFICATION OF TYPE IIB (IBC §602.2).
THE FIRE-RESISTANCE REQUIREMENTS FOR BUILDING ELEMENTS OF TYPE IIB CONSTRUCTION (IBC TABLES 601 AND 602):
STRUCTURAL FRAME (INCLUDING COLUMNS, GIRDERS, AND TRUSSES) 0 HOUR
INTERIOR BEARING WALLS 0 HOUR
INTERIOR NONBEARING WALLS 0 HOUR
EXTERIOR WALLS
WITH FIRE SEPARATION DISTANCE OF AT LEAST 10 FT 0 HOUR
FLOOR CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS) 0 HOUR
ROOF CONSTRUCTION (INCLUDING SUPPORTING BEAMS AND JOISTS) 0 HOUR
BUILDING SEPARATION
THE ARMS RANGE BUILDING HAS A FIRE SEPARATION DISTANCE (FSD) OF AT LEAST 30 FT ON ALL SIDES OF THE BUILDING; THEREFORE, NO EXTERIOR WALL RATINGS ARE REQUIRED IN ACCORDANCE WITH IBC TABLE 602.
ALLOWABLE HEIGHT AND AREA
BASED ON NONSEPARATED MIXED USE OF B AND F-1 IBC §508.3
STORIES: 3 ALLOWED/ 1 ACTUAL IBC TABLE 504.4
FEET: 75 FT ALLOWED/ 43 FT ACTUAL IBC TABLE 504.3
OCCUPANCY BASE ALLOWED (SQ. FT.) TOTAL ALLOWABLE PER FLOOR (SQ. FT.)
B 23,000 23,000 F-1 15,500 15,500
BASED ON TYPE IIB, ONE STORY, NON SPRINKLERED BUILDING, THE MAXIMUM ALLOWABLE AREA PER FLOOR FOR THE NON-
SEPARATED MIXED USE BUILDING OF B AND F-1 IS 15.500 SQ. FT.
ACTUAL AREA:
TOTAL GROSS BUILDING AREA: 8,759 SQ. FT.
FIRE/SMOKE RESISTANCE RATED SEPARATIONS
RATING REFERENCE
TRAINING AND DIRECT TRAINING SUPPORT 2-HOUR UFC 4-179-02, §4-6
CORRIDORS 0-HOUR NFPA 101 §42.3.6
MECHANICAL SPACE W/ FUEL BURNING EQUIPMENT 1-HR NFPA 101 §38.3.2.1 & §8.7.1.2
STORAGE (OTHER THAN OFFICE SUPPLIES) 1-HR NFPA 101 §38.3.2.1 & §8.7.1.2
OPENING PROTECTION
TYPE OF ASSEMBLY FIRE DOOR FIRE DAMPER SMOKE DAMPER
AND RATING ASSEMBLY RATING RATING RATING REFERENCE
2 HR FIRE BARRIER 1-1/2 HR 1.5 HR N/A NFPA 221 TABLE 4.9.2, NFPA 90A §5.3.1.2
1 HR FIRE BARRIER 0.75 HR 1 HR N/A NFPA 221 TABLE 4.9.2, NFPA 90A §5.3.1.2
INTERIOR FINISHES
INTERIOR WALL AND CEILING FINISH IN EXITS CLASS A OR B NFPA 101 TABLE A.10.2.2
INTERIOR WALL AND CEILING FINISH IN ALL OTHER AREAS CLASS A, B, OR C NFPA 101 TABLE A.10.2.2
INTERIOR FLOOR FINISH CLASS I OR II NFPA 101 TABLE A.10.2.2
FIRE SUPPRESSION
THIS BUILDING IS LESS THAN 15,000 SQ. FT. AND DOES NOT REQUIRE AN AUTOMATIC SPRINKLER SYSTEM PER UFC 3-600-01 SECTION 9-7.2.1.1.
FIRE ALARM/MASS NOTIFICATION
BUILDING IS PROVIDED WITH A COMBINATION MONACO MAAP-X FIRE ALARM AND MASS NOTIFICATION SYSTEM. REFER TO THE FA
SERIES DRAWINGS.
SYSTEM REPORTING SHALL BE TO THE BASE CENTRAL MONITORING STATION.
PORTABLE FIRE EXTINGUISHERS:
HAZARD CLASSIFICATION: NFPA 10 §5.2 & §5.4
LIGHT HAZARD CLASS A: OFFICE AREAS
MAXIMUM TRAVEL DISTANCE TO FE: 75 FEET
MAXIMUM FLOOR AREA PER UNIT A: 3,000 SQ.FT.
MAXIMUM FLOOR AREA FOR FE: 11,250 SQ.FT.
ORDINARY HAZARD CLASS A: STORAGE ROOMS
MAXIMUM TRAVEL DISTANCE TO FE: 75 FEET
MAXIMUM FLOOR AREA PER UNIT A: 1,500 SQ.FT.
MAXIMUM FLOOR AREA FOR FE: 11,250 SQ.FT.
EXTINGUISHER FOR CLASS C HAZARDS SHALL BE LOCATED ON THE BASIS OF THE ANTICIPATED CLASS A HAZARDS (NFPA 10 §6.4.3).
DESIGN BASIS: 10 POUND MULTIPURPOSE DRY CHEMICAL: 4A:80B:C
FIRE DEPARTMENT ACCESS
BUILDING SHALL HAVE AT LEAST ONE MEANS OF ALL-WEATHER GROUND ACCESS TO ALLOW EMERGENCY VEHICLES UNIMPEDED ACCESS TO THE FACILITY. ALL-WEATHER GROUND ACCESS MUST BE PAVED, START FROM THE ROAD, AND TERMINATE NO FARTHER THAN 33 FEET FROM AN EXTERIOR DOOR ACCESSIBLE FOR FIRE DEPARTMENT INGRESS (I.E. AN EXTERIOR DOOR THAT PROVIDES
ACCESS TO THE FACILITY INTERIOR). (UFC 3-600-01 §9-1.1)
DIMENSIONS OF FIRE LANES AND TURNAROUNDS MUST COMPLY WITH NFPA 1 (UFC 3-600-01 §9-1.3). FIRE DEPARTMENT ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF NOT LESS THAN 20 FT AND AN UNOBSTRUCTED VERTICAL CLEARANCE OF NOT LESS THAN 13 FT 6 IN (NFPA 1 §18.2.3.5.1.1 AND §18.2.3.5.1.2). DEAD END FIRE DEPARTMENT ACCESS ROADS IN EXCESS OF 150 FT IN LENGTH SHALL BE PROVIDED WITH APPROVED PROVISIONS FOR THE FIRE APPARATUS TO TURN AROUND (NFPA 1 §18.2.3.5.4).
WATER SUPPLY
PRIVATE FIRE SERVICE MAINS SUPPLYING FIRE HYDRANTS.
FIRE FLOW
THE ARMS RANGE HAS A TOTAL FLOOR AREA OF 8,759 SQ. FT. AND IS OF TYPE IIB (000) CONSTRUCTION WHICH RESULTS IN A REQUIRED FIRE FLOW OF 2,250 GPM FOR 2 HOURS IN ACCORDANCE WITH NFPA 1 TABLE 18.4.5.2.1.
MEANS OF EGRESS
ALL COMPONENTS AND FEATURES RELATED TO MEANS OF EGRESS SHALL COMPLY NFPA 101 AND UFC 3-600-01 (UFC 3-600-01 §10-1.1).
THE OCCUPANCY LOADS ARE DETERMINED BASED ON THE AREA, FUNCTION OF THE SPACE, AND THE OCCUPANT LOAD FACTOR (SQ.
FT. /PERSON). THE OCCUPANT LOAD FACTORS ARE PROVIDED IN UFC 3-600-01 TABLE 10-1 AND NFPA 101 TABLE 7.3.1.2. THE OCCUPANT LOAD FACTOR IS BASED ON THE ACTUAL USE OF THE SPACE, NOT ON ITS OCCUPANCY CLASSIFICATION. OCCUPANT LOAD
CALCULATIONS ARE PROVIDED ON THE LIFE SAFETY FLOOR PLAN.
MINIMUM NUMBER OF MEANS OF EGRESS REQUIRED:
OCCUPANT LOAD 1-500: NOT LESS THAN 2 EXITS REQUIRED NFPA 101 §7.4.1.1
THE EGRESS/EXIT CAPACITY FOR AN EXIT IS DETERMINED BY DIVIDING THE CLEAR WIDTH OF THE EXIT, AS DETERMINED IN
ACCORDANCE WITH NFPA 101 §7.2.1.2.1, BY THE EGRESS CAPACITY FACTOR.
EGRESS CAPACITY FACTORS: NFPA 101 TABLE 7.3.3.1
LEVEL COMPONENTS & RAMPS: 0.2 INCHES PER OCCUPANT SERVED
EXIT CAPACITY CALCULATION FOR EACH EXIT IS SHOWN ON THE LIFE SAFETY FLOOR PLAN.
THE MINIMUM SEPARATION DISTANCE BETWEEN TWO EXITS, EXIT ACCESSES, OR EXIT DISCHARGES, SHALL BE NOT LESS THAN ONE- HALF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED (NFPA 101 §7.5.1.3.2).
THE DISTANCE SHALL BE MEASURED IN A STRAIGHT LINE BETWEEN THE NEAREST EDGE OF THE EXITS, EXIT ACCESSES, OR EXIT
DISCHARGES (NFPA 101 §7.5.1.3.2).
DOORS ARE REQUIRED TO SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA WITH AN OCCUPANT LOAD OF 50 OR MORE, THE DOOR IS PART OF AN EXIT ENCLOSURE, OR WHERE THE DOOR OPENING SERVES A HIGH HAZARD
CONTENTS AREA (NFPA 101 §7.2.1.4.2).
ALL LOCKS, LATCHES AND ALL OTHER FASTENING DEVICES ON A DOOR LEAF SHALL BE PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS (NFPA 101 §7.2.1.5.3).
MEANS OF EGRESS CONTINUED:
TRAVEL DISTANCE LIMIT: NFPA 101 TABLE A.7.6
GENERAL INDUSTRIAL: 200 FEET
NEW BUSINESS: 200 FEET
COMMON PATH LIMIT: NFPA 101 TABLE A.7.6
GENERAL INDUSTRIAL: 50 FEET
NEW BUSINESS: 75 FEET
DEAD-END LIMIT: NFPA 101 TABLE A.7.6
GENERAL INDUSTRIAL: 50 FEET
NEW BUSINESS: 20 FEET
WHERE THE CONTENTS ARE CLASSIFIED AS HIGH HAZARD, EXITS SHALL BE PROVIDED AND ARRANGED TO ALLOW ALL OCCUPANTS TO ESCAPE FROM THE BUILDING OR STRUCTURE, OR FROM THE HAZARDOUS AREA THEREOF, TO THE OUTSIDE OR TO A PLACE OF SAFETY WITH A TRAVEL DISTANCE OF NOT MORE THAN 75 FT (NFPA 101 §7.11.1). NFPA 101 §7.11.1 DOES NOT LIMIT OCCUPANTS TO A 75 FT TRAVEL DISTANCE BUT REQUIRES ESCAPE FROM THE HIGH HAZARD CONTENTS AREA ITSELF WITH NOT MORE THAN 75 FT OF TRAVEL. THE PLACE OF SAFETY OUTSIDE THE HIGH HAZARD AREA IS PERMITTED TO BE WITHIN THE BUILDING’S EXIT ACCESS AND
ADDITIONAL TRAVEL MIGHT BE NECESSARY TO REACH AN EXIT.
ACCESSIBLE MEANS OF EGRESS:
ACCESSIBLE MEANS OF EGRESS IS REQUIRED TO COMPLY WITH NFPA 101 (UFC 3-600-01 §10-1.2). AN ACCESSIBLE MEANS OF EGRESS IS DEFINED AS A MEANS OF EGRESS THAT PROVIDES AN ACCESSIBLE ROUTE TO AN AREA OF REFUGE, A HORIZONTAL EXIT, OR A PUBLIC
WAY (NFPA 101 §3.3.180.1).
THE BUILDING IS REQUIRED TO HAVE AT LEAST TWO ACCESSIBLE MEANS OF EGRESS (NFPA 101 §7.5.4.1). ACCESS WITHIN THE ALLOWABLE TRAVEL DISTANCE IS PROVIDED TO AT LEAST ONE ACCESSIBLE AREA OF REFUGE OR ONE ACCESSIBLE EXIT PROVIDING AN ACCESSIBLE ROUTE TO AN EXIT DISCHARGE (NFPA 101 §7.5.4.1.1). EXIT ACCESS TRAVEL ALONG THE ACCESSIBLE MEANS OF EGRESS IS PERMITTED TO BE COMMON FOR THE DISTANCES PERMITTED AS COMMON PATHS OF TRAVEL (NFPA 101 §7.5.4.1.4). THERE
ARE EIGHT ACCESSIBLE MEANS OF EGRESS PROVIDED FOR THIS FACILITY.
MEANS OF EGRESS ILLUMINATION
ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 101 §7.8 (NFPA 101 §40.2.8). NATURAL LIGHT THAT PROVIDED THE REQUIRED LEVEL OF ILLUMINATION IN THE INDUSTRIAL OCCUPANCY PROVIDED THAT THE SPACE IS OCCUPANCY ONLY DURING DAYLIGHT HOURS (NFPA 101 §40.2.8). ILLUMINATION OF MEANS OF EGRESS SHALL BE CONTINUOUS DURING TIMES OF OCCUPANCY (NFPA 101 §7.8.1.2). ILLUMINATION PROVIDED OUTSIDE THE BUILDING SHOULD BE TO EITHER A PUBLIC WAY OR A DISTANCE AWAY FROM THE BUILDING THAT IS CONSIDERED SAFE, WHICHEVER IS CLOSEST TO THE BUILDING BEING EVACUATED.
FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT OR WITHIN PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE ARE PROVIDED WITH A MINIMUM ILLUMINATION OF 1 FOOT-CANDLE (FTC; 10.8 LUX) MEASURED AT THE FLOOR (NFPA 101 §7.8.1.3(2)).
THE REQUIRED ILLUMINATION IS ARRANGED SO THAT THE FAILURE OF ANY SINGLE LIGHTING UNIT DOES NOT RESULT IN AN ILLUMINATION LEVEL OF LESS THAN 0.2 FTC (2.2 LUX) IN ANY DESIGNATED AREA (NFPA 101 §7.8.1.4).
AUTOMATIC LIGHTING CONTROL DEVICES ARE PERMITTED AND SHALL BE USED TO TEMPORARILY TURN OFF THE ILLUMINATION WITHIN THE MEANS OF EGRESS, AND EACH LIGHTING CONTROL DEVICE SHALL COMPLY WITH ALL OF THE FOLLOWING (NFPA 101 §7.8.1.2.2):
• THE LIGHTING CONTROL DEVICE SHALL BE LISTED.
• THE LIGHTING CONTROL DEVICE SHALL BE EQUIPPED TO AUTOMATICALLY ENERGIZE THE CONTROLLED LIGHTS UPON LOSS
OF NORMAL POWER AND IS EVALUATED FOR THIS PURPOSE.
• ILLUMINATION TIMERS ARE PROVIDED AND ARE SET FOR A MINIMUM 15-MINUTE DURATION.
• THE LIGHTING CONTROL DEVICE IS ACTIVATED BY ANY OCCUPANT MOVEMENT IN THE AREA SERVED BY THE LIGHTING
UNITS.
• THE LIGHTING CONTROL DEVICE SHALL BE ACTIVATED BY ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM.
• THE LIGHTING CONTROL DEVICE SHALL NOT TURN OFF ANY LIGHTS RELIED UPON FOR ACTIVATION OF
PHOTOLUMINESCENT EXIT SIGNS OR PATH MARKERS (IF APPLICABLE).
• THE LIGHTING CONTROL DEVICE DOES NOT TURN OFF ANY BATTERY-EQUIPPED EMERGENCY LUMINAIRES, UNIT
EQUIPMENT, OR EXIT SIGNS.
EMERGENCY LIGHTING
EMERGENCY LIGHTING MUST BE PROVIDED FOR MEANS OF EGRESS IN ACCORDANCE WITH NFPA 101 (NFPA 101 §40.2.9). EMERGENCY LIGHTING IS ALLOWED TO BE OMITTED IN THE INDUSTRIAL OCCUPANCY WHERE AREAS ARE ONLY OCCUPIED DURING DAYLIGHT HOURS, WITH SKYLIGHTS OR WINDOWS ARRANGED TO PROVIDE REQUIRED LEVEL OF ILLUMINATION ON ALL PORTIONS OF THE MEANS
OF EGRESS DURING SUCH HOURS.
EMERGENCY ILLUMINATION IS PROVIDED FOR A MINIMUM OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL LIGHTING PER NFPA 101 §7.9.2.1. EMERGENCY LIGHTING FACILITIES ARE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NO LESS THAN AN AVERAGE OF 1 FTC (10.8 LUX) AND, AT ANY POINT, NO LESS THAN 0.1 FTC (1.1 LUX), MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL (NFPA 101 §7.9.2.1.1). ILLUMINATION LEVELS ARE PERMITTED TO DECLINE TO NO LESS THAN AN AVERAGE OF 0.6 FTC (6.5 LUX) AND, AT ANY POINT, NO LESS THAN 0.06 FTC (0.65 LUX) AT THE END OF 1.5 HR. (NFPA 101 §7.9.2.1.2). A MAXIMUM-TO-MINIMUM ILLUMINATION
UNIFORMITY RATIO OF 40 TO 1 IS NOT TO BE EXCEEDED (NFPA 101 §7.9.2.1.3).
THE EMERGENCY LIGHTING SYSTEM MUST BE ARRANGED TO PROVIDE THE REQUIRED ILLUMINATION AUTOMATICALLY WHEN NORMAL LIGHTING IS INTERRUPTED DUE TO FAILURE OF A PUBLIC UTILITY OR OTHER OUTSIDE ELECTRICAL POWER SUPPLY, THE OPENING OF A CIRCUIT BREAKER OR FUSE, OR MANUAL ACT(S), INCLUDING ACCIDENTAL OPENING OF A SWITCH CONTROLLING NORMAL LIGHTING
FACILITIES (NFPA 101 §7.9.2.3).
MARKING OF MEANS OF EGRESS
MARKING OF MEANS OF EGRESS SHALL BE IN ACCORDANCE WITH NFPA 101 §7.10 (NFPA 101 §40.2.10). EXIT SIGNS INDICATING THE DIRECTION OF EGRESS WILL BE PROVIDED IN ACCORDANCE WITH NFPA 101. EXIT SIGNS WILL BE PLACED AT ALL EXIT DOORS (NFPA 101 §7.10.1.2.1). HORIZONTAL COMPONENTS OF THE EGRESS PATH ARE MARKED BY APPROVED EXIT OR DIRECTIONAL EXIT SIGNS WHERE THE CONTINUATION OF THE EGRESS PATH IS NOT OBVIOUS. EXIT SIGNS ARE PLACED SO THAT NO POINT IN AN EXIT ACCESS CORRIDOR EXCEEDS THE RATED VIEWING DISTANCE OR 100 FT, WHICHEVER IS LESS, FROM THE NEAREST SIGN (NFPA 101 §7.10.1.5.2).
INCANDESCENT OR FLUORESCENT FIXTURES ARE NOT PERMITTED FOR NEW INSTALLATION OR REPLACEMENT OF FIXTURES (UFC 3-600-01 §10-2.1.1). RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED (UFC 3-600-01 §10-2.2).
PHOTOLUMINESCENT EXIT SIGNS AND EGRESS PATH MARKINGS ARE PERMITTED PROVIDED THEY ARE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 101 (UFC 3-600-01 §10-2.3.1). THE ILLUMINATION SOURCE MUST BE ENERGIZED AT ALL TIMES DURING BUILDING OCCUPANCY. SUCH LIGHTING MUST NOT BE CONTROLLED BY AUTOMATIC TIMERS, AUTOMATIC SENSORS, INCLUDING ARE OCCUPANCY SENSORS, OR ACCESSIBLE MANUAL SWITCHES.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
F ir e L a n e C
F .r v t
/1
/2
:1
:3
A
M
GI002
C
E N
N
IS
K
C L A
Y
N
S A
N M
A N
N
D
M O
T L E
Y F
P
LS
F O
R M
C E
R T
IF
IE
D F
IN
A
L
M
AY
3, G E
N E
R A
L
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
F ir e L a n e C
F .r v t
/1
/2
:1
:3
A
M
GI003
C
E N
N
IS
K
C L A
Y
N
S A
N M
A N
N
D
M O
T L E
Y F
P
LS
F O
R M
C O
N T
C E
R T
IF
IE
D F
IN
A
L
M
AY
3, G E
N E
R A
L
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
F FF F F F F F F F F F F F F F F F
F F
F F
F
F F
F F
F F
F F
F F
F F
F F
F
F F
F F
F
F
F
F F
F F
201-7"
202'-4"
193'-1"
KB
INTENDED FIRE
DEPARTMENT MAIN
ENTRANCE
184'-6"
0"
30' - 0"
SITE SAFETY SYMBOLS AND LEGEND
DISTANCE FROM BUILDING, FEET
EXISTING FIRE WATER LINE
FIRE WATER LINE
FIRE HOSE LAY DISTANCE, FEET
EXISTING SECTION CONTROL VALVE
EXISTING FIRE HYDRANT
SECTION CONTROL VALVE
FIRE HYDRANT
KEYED LOCK BOX
1. MORE THAN 20 FEET WIDE, WHICH IS SUFFICIENT FOR FIRE
DEPARTMENT APPARATUS ONE-WAY ACCESS PER UFC 3-600-01.
2. FLOW TEST GAUGE HYDRANT.
3. FLOW TEST FLOW HYDRANT.
4. HYDRANT TO BE PROVIDED WITH BOLLARDS AS IT IS LOCATED
ADJACENT TO PARKING AREAS. REFER TO CIVIL DRAWINGS FOR
NUMBER AND LOCATION.
KEYED NOTES :#
GENERAL NOTES
1. BUILDING, FIRE LINE, AND WATER LINE SHOWN FOR GENERAL LIFE
SAFETY INFORMATION ONLY. REFER TO CIVIL DRAWINGS FOR MORE
DETAILS.
2. FIRE HYDRANTS ARE ON DOMESTIC WATER SUPPLY LOOP.
## FT
## FT
KB
SHEET ID
D E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
F ir e L a n e C
F .r v t
/1
/2
:1
:3
A
M
GI010
C
E N
N
IS
K
C L A
Y
N
S A
N M
A N
N
D
M O
T L E
Y C
O D
E C
O M
P
LI
A N
C E
S
IT
E P
LA
N
C E
R T
IF
IE
D F
IN
A
L
M
AY
3, G E
N E
R A
L
1" = 20'-0"1
CODE COMPLIANCE SITE PLAN N
MCSATS CATM
KEY PLAN
KEY PLAN
SCALE IN FEET - 1" = 20'-0"
20' 10' 0' 20' 60'40'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
C
F
F
F
F
F
F
F
F
C
C
C
C
S
S
S
S
C
C
C
C
C
C
C
ET
ET
ET
ET
CO
CO
S
S
S
SS
S
P
FMCU
TSP
C
S
CC
C
C
S
C
S
LOC
A A
B B
0.2
34"
0.2
34"
0.2
68"
0.2
34"
0.2
34"
0.2
34"
0.2
34"
TD: 50' - 4"
TD: 113' - 0"
1.5
TD: 38' - 10"
1.5118-A
0.2
34"
ARMS RANGE
BULLET TRAP
MECHANICAL
ACP VESTIBULE
106 CLASSROOM
CORRIDOR
RSO
ACP VESTIBULE
RANGE STORAGE
JANITOR AND
LAUNDRY
ELECTRICAL
CORRIDOR
TD: 49' - 10 1/2"
115-A
102-B 119-A
102-A105-A
115-B118-B
FEC
3/4
LCP
AOM
MAU-2
S
MAU-1
S
CP:40' - 4"
DE:7' - 6"
WEAPONS MX AND
CLEANING
1.5
2 HOUR FIRE RATED BARRIER
FIRE RATED BARRIER SYMBOLOGY
1 HOUR FIRE RATED BARRIER
EXIT ACCESS TRAVEL PATH
COMMON PATH OF TRAVEL
DEAD END DISTANCE
ACCESSBILE ENTRANCE/EXIT
EXIT LIGHT CEILING MOUNT
EXIT LIGHT WALL MOUNT
FIRE EXTINGUISHER CABINET
FIRE RATED DOOR (X=DOOR RATING)
FIRE DAMPER
LIFE SAFETY LEGEND
OCCUPANCY CLASSIFICATION
NFPA 101: BUSINESS
IBC: BUSINESS, GROUP B
NFPA 101: GENERAL INDUSTRIAL
IBC: FACTORY, GROUP F-1
DOOR NUMBERXXXX
XX"
.X
XXX
XX
CLEAR WIDTH
WIDTH FACTOR
EXIT CAPACITY
ASSIGNED CAPACITY
X
FEC
WALL MOUNTED FIRE ALARM/MNS
SPEAKER/STROBE, XX INDICATES CD
RATING
CEILING MOUNTED FIRE ALARM/MNS
SPEAKER/STROBE, XX INDICATES CD
RATING
SYMBOL DESCRIPTION
CARBON MONOXIDE DETECTOR
SMOKE DETECTOR - PHOTOELECTRIC
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE
WALL MOUNTED FIRE ALARM/MNS
SPEAKER
SYMBOL DESCRIPTION
MANUAL PULL STATION
C
XX
CEILING MOUNTED FIRE ALARM/MNS
SPEAKER
C
S
S
XX
P
CO
AIM
AOM
F
RADIO ANTENNA
SPD SURGE PROTECTION DEVICE
FIRE ALARM / MASS NOTIFICATION SYSTEM SYMBOLS LEGEND
FI
ET
END OF LINE RESISTOR
FIBER INTERFACE
EMERGENCY TEXT SIGN LOC LOCAL OPERATING CONSOLE
XX
R/S
DUCT SMOKE DETECTOR; XX INDICATES
ASSOCIATED UNIT; R=RETURN, S=SUPPLY
TSP TEXT SIGN PANELFMCU FIRE ALARM / MNS CONTROL UNIT
SHEET ID
D E
S
IG
N B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
J R
P L
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
A
R
IC
K E
N B
A C
K E
R
IN
T E
R N
A T
IO
N
A L
A
IR
P O
R T
A
N G
O
H
IO
O H
IO
A
IR
N
A T
IO
N
A L
G U
A R
D A
N G
S M
A
LL
A R
M S
R A
N G
E P
2# : 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
F ile
P a th
P lo t D a te
US Army Corps of Engineers ®
IS
S
U E
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
S
IZ
E
A N
S I D
. . P R
O J E
C T
N O
N L
Z G
B
IM
/1 U
S A
C E
S m a ll
A rm s R a n g e r
J V
R
/1
F ir e L a n e C
F .r v t
/1
/2
:1
:4
A
M
GI110
C
E N
N
IS
K
C L A
Y
N
S A
N M
A N
N
D
M O
T L E
Y
LI
F E
S A
F E
T Y
P
LA
N
C O
M P
O S
IT
E
C E
R T
IF
IE
D F
IN
A
L
M
AY
3, G E
N E
R A
L
1/8" = 1'-0"1
LIFE SAFETY PLAN - COMPOSITE
OCCUPANT LOAD CALCULATIONS
ROOM / AREA FUNCTION / USE SQ. FT. OCCUPANT LOAD FACTOR OCCUPANTS
CLASSROOM ASSEMBLY 365.86 15 SF / PERSON NET 25 PERSONS
TOILETS & SHOWER BUSINESS 142.41 150 SF / PERSON GROSS 1 PERSON
RSO BUSINESS 206.22 150 SF / PERSON GROSS 2 PERSONS
MECHANICAL BUILDING EQUIP. 88.27 500 SF / PERSON GROSS 1 PERSON
ELECTRICAL BUILDING EQUIP. 128.26 500 SF / PERSON GROSS 1 PERSON
JANITOR AND LAUNDRY BUILDING EQUIP. 77.98 500 SF / PERSON GROSS 1 PERSON
RANGE STORAGE STORAGE 88.87 500 SF / PERSON GROSS 1 PERSON
BULLET TRAP BUILDING EQUIP. 1,328.00 500 SF / PERSON GROSS 3 PERSONS
WEAPONS MIX/CLEANING BUSINESS 414.25 150 SF/ PERSON GROSS 3 PERSONS
REMAINDER OF BUILDING INDUSTRIAL 5,918.88 100 SF / PERSON GROSS 60 PERSONS
TOTALS 8,759 98 PERSONS
N
MCSATS CATM
KEY PLAN
KEY PLAN
SCALE IN FEET - 1/8" = 1'-0"
8' 4' 0' 8' 24'16'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C
E R
T
IF
IE
D
F
IN
A L
D C
M
W
2Q R
BA
7_
Pl an s-
VI
IN
IT
Y M
AP
VICINITY MAP
J
PO
LL
M
AN
J
BE
AN
R P
EA
R
SO
N
D M
O
TL
EY
C
ER
TI
FI
ED
F
IN
AL
M
AY
3, M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N
LZ
G
C
ER
TI
FI
ED
F
IN
AL
D
C M
SHEET ID
D
ES
IG
N
B Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SU
BM
IT
TE
D B
Y:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
D
R M
AR
TI
N L
U
TH
ER
J
R P
L
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
A
RI
CK
EN
BA
CK
ER
IN
TE
RN
AT
IO
NA
L A
IR
PO
RT
(A
NG
OH
IO
OH
IO
A
IR
N
AT
IO
NA
L G
UA
RD
AN
G
SM
AL
L A
RM
S
RA
NG
E
P 2#
CI
VI
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
Fi le
P at h:
Pl ot D at e:
US Army Corps of Engineers ®
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
SI
ZE
AN
SI
D
. . PR
O
JE
C
T N
O
PRELIMINARY
NOT FOR
CONSTRUCTION
SITE LOCATION AND PROPOSED HAUL ROUTE MAP
NOT TO SCALENOT TO SCALE
Fi le
P at h:
C-001
PROJECT LOCATION
PROPOSED CONSTRUCTION
STAGING & LAYDOWN YARD
PROJECT LOCATION
PROPOSED
CONSTRUCTION
ACCESS/HAUL ROAD
PROJECT LOCATION
PROJECT LOCATION
PROPOSED
CONSTRUCTION
ACCESS/HAUL ROAD
ALTERNATE PATH
PROJECT LOCATION
NOTES:
PROVIDE TEPORARY SECURITY FENCING ALONG THE CONSTRUCTION SITE AND AT ALL OPEN
EXCAVATIONS AND TUNNELS TO CONTROL ACCESS BY UNAUTHORIZED PERSONNEL. SAFETY FENCING MUST BE HIGHLY VISIBLE TO BE SEEN BY PEDESTRIANS AND VEHICULAR TRAFFIC. ALL FENCING MUST MEET THE REQUIREMENTS OF EM 385-1-1. REMOVE THE FENCE UPON COMPLETION AND ACCEPTANCE
OF THE WORK. REFER TO CIVIL DRAWINGS FOR LAYOUT AND REQUIREMENTS OF TEMPORARY
SECURITY FENCING.
PROPOSED
CONSTRUCTION
ACCESS/HAUL ROAD
ALTERNATE PATH
W
2Q R
BA
7_
Pl an s-
G
EN
ER
AL
N O
TE
S
C-002
PERMITS
1. THE CONTRACTOR WILL OBTAIN AS REQUIRED, AND PAY ALL RELATED COSTS AS INCIDENTAL TO THE
CONTRACT, THE FOLLOWING RELATED PROJECT PERMITS:
· ANY REQUIRED RIGHT-OF-WAY ENCROACHMENT PERMIT
· ANY REQUIRED ENVIRONMENTAL PERMIT OR AGREEMENT
· OH EPA NOTICE OF INTENT (NOI)
· OHIO DIVISION OF PLUMBING PERMIT
· OHIO ELECTRICAL PERMIT
· BUILDING PERMIT (LOCAL MUNICIPALITY)
3. COPIES OF ALL PERMITS SHALL BE MAINTAINED ONSITE BY THE CONTRACTOR AT ALL TIMES.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL PERMITS, THE COST OF WHICH SHALL BE INCIDENTAL TO THE CONTRACT. ANY PENALTIES OR FINES FOR PERMIT NON-COMPLIANCE SHALL BE BORNE
SOLELY BY THE CONTRACTOR.
5. CONTRACTOR SHALL SUBMIT TO THE OHANG, FOR REVIEW AND APPROVAL, PEDESTRIAN AND VEHICULAR TRAFFIC CONTROL PLANS (TCP). ANY TCP SHALL BE IN COMPLIANCE WITH THE LATEST VERSION OF THE
MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).
NOTICES
1. THE CONTRACTOR SHALL NOTIFY THE OHANG AT LEAST 48 HOURS PRIOR TO BEGINNING ANY CONSTRUCTION.
2. THE CONTRACTOR SHALL REQUEST, AT LEAST 72 HOURS IN ADVANCE, PERMISSION TO WORK OUTSIDE THE
SPECIFIED WORK HOURS OR FOR ANY WEEKEND WORK.
3. THE CONTRACTOR SHALL NOTIFY THE OHANG AT LEAST FORTY EIGHT (48) HOURS BEFORE REQUIRED INSPECTION ON EACH AND EVERY PHASE OF WORK. THE CONTRACTOR SHALL NOTIFY THE OHANG A MINIMUM OF FORTY EIGHT (48) HOURS PRIOR TO ANY SCHEDULED TESTING. NO PRESSURE TESTING OR FINAL TESTING
WILL BE ACCEPTED UNLESS WITNESSED BY THE OHANG.
SURVEYING
1. THE CONTRACTOR SHALL VERIFY ALL HORIZONTAL AND VERTICAL CONTROL SHOWN ON THE PLANS. THE OHANG SHALL BE NOTIFIED OF ANY CONFLICTS PRIOR TO INITIATION OF ANY CONSTRUCTION WORK.
2. THE CONTRACTOR(S) IS RESPONSIBLE FOR ITS RESPECTIVE SURVEYING AND LAYOUT FROM THE HORIZONTAL
AND VERTICAL CONTROL PROVIDED ON THE PLANS.
3. ANY SURVEY MONUMENT DISTURBED DURING CONSTRUCTION SHALL BE REPLACED UPON COMPLETION OF
THE WORK BY A REGISTERED LAND SURVEYOR.
4. THE CONTRACTOR SHALL MAINTAIN INDEPENDENT RECORDS OF ALL CONSTRUCTION WHICH SHALL BE SUBMITTED TO THE OHANG UPON COMPLETION OF CONSTRUCTION. THE RECORD SHALL SHOW FINAL VERTICAL AND HORIZONTAL ALIGNMENT OF ALL BURIED UTILITIES ADDED OR MOVED AS A RESULT OF CONSTRUCTION. THE RECORDS SHALL INCLUDE ALL LINES, ACTUAL FIELD ANGLES BETWEEN LINES, SERVICE LINES AND TEE LOCATIONS, VALVE VAULTS AND VALVE BOXES, AND STUB-OUTS. THE RECORDS SHALL
REFLECT ALL ALIGNMENT AND GRADE CHANGES FROM THE DESIGN DRAWINGS MADE DURING
CONSTRUCTION.
GENERAL
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES, ORDINANCES, REGULATIONS, AND OTHER REQUIREMENTS NECESSARY TO COMPLETE THE WORK. THIS INCLUDES PROVISIONS FOR VEHICULAR AND PEDESTRIAN TRAFFIC CONTROL AND SAFETY, BUILDING CODES, MANUFACTURING CODES (ASTM AND ACI, AND THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)).
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. IN CASES WHERE CONFLICTS EXIST BETWEEN OHANG STANDARD SPECIFICATIONS OR STANDARD DRAWINGS, THE CONTRACT DOCUMENTS SHALL PREVAIL. THE OHANG SHALL HAVE FINAL DETERMINATION IN ANY CONFLICTS.
3. ALL CONSTRUCTION OF EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES (BMPS) SHALL BE IN ACCORDANCE WITH OHIO DEPARTMENT OF ENVIRONMENTAL MANAGEMENT STORMWATER QUALITY
MANUAL LATEST EDITION.
4. DEVIATIONS FROM THE PLANS AND SPECIFICATIONS SHALL BE PERMITTED ONLY WHEN APPROVED BY THE
CONTRACTING OFFICER.
5. PRIOR TO BID PREPARATION, THE CONTRACTOR MUST BECOME FAMILIAR WITH THE OVERALL SITE CONDITIONS AND PERFORM ADDITIONAL INVESTIGATIONS AS DETERMINED NECESSARY TO UNDERSTAND THE ADEQUACY OF EXISTING MATERIALS SUCH AS FILL, DEWATERING REQUIREMENTS, CLEAN FILL REQUIRED FROM OFFSITE, AND MATERIALS TO BE DISPOSED OF OFFSITE. ANY DELAY, INCONVENIENCE, OR EXPENSE CAUSED TO THE CONTRACTOR DUE TO INADEQUATE INVESTIGATION OF EXISTING CONDITIONS SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED. ANY MATERIALS ANTICIPATED TO BE ENCOUNTERED DURING CONSTRUCTION MAY REQUIRE DRYING PRIOR TO USE AS BACKFILL, AND THE CONTRACTOR MAY HAVE TO IMPORT MATERIALS, AT NO EXTRA COST TO THE OWNER, FROM OFFSITE TO MEET THE REQUIREMENTS FOR COMPACTION AND PROPER FILL.
6. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR, MATERIAL, EQUIPMENT, TOOLS, AND SERVICES
REQUIRED TO COMPLETE CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. SHOP DRAWINGS SHALL BE SUBMITTED AS SPECIFIED IN THE PROJECT SPECIFICATIONS.
8. THE CONTRACTOR SHALL MAINTAIN A COPY OF THE SPECIFICATIONS AND DRAWINGS ON-SITE THROUGHOUT
CONSTRUCTION.
10. THE CONTRACTOR SHALL PROTECT UTILITIES AND OTHER IMPROVEMENTS SHOWN ON THESE PLANS, ALONG WITH OTHER UTILITIES AND OTHER IMPROVEMENTS NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF UTILITIES AND OTHER IMPROVEMENTS DAMAGED DURING CONSTRUCTION AS DIRECTED BY THE OHANG, AT NO ADDITIONAL COST TO THE OWNER, AND SHALL MAINTAIN SUFFICIENT PROTECTION TO UTILITIES REQUIRED TO PROTECT THEM FROM DAMAGE AND TO PROTECT THE PUBLIC
DURING CONSTRUCTION.
GENERAL CONSTRUCTION
1. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING STRUCTURE, FACILITY, OR LANDSCAPING DAMAGED DUE TO CONSTRUCTION ACTIVITIES. THIS WORK SHALL BE AT NO ADDITIONAL COST TO THE
OWNER.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING ANY CONSTRUCTION ACTIVITIES FROM TAKING PLACE OUTSIDE OF THE LIMITS OF CONSTRUCTION SHOWN ON THE PLANS. ANY ON-SITE OR OFF-SITE AREAS DISTURBED SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER. RESTORATION OF WORK OUTSIDE THE
LIMITS OF CONSTRUCTION SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
3. UPON COMPLETION OF CONSTRUCTION, ALL AREAS SHALL BE COMPLETELY CLEAR OF ALL TIMBER, BRUSH, STUMPS, ROOTS, GRASS, WEEDS, RUBBISH, ROCKS (ONE-INCH AND LARGER), AND ALL OTHER DEBRIS AND
OBSTRUCTIONS RESTING ON OR PROTRUDING THROUGH THE SURFACE OF THE GROUND.
4. CONTRACTOR SHALL ADJUST ELEVATION TO FINAL GRADE ANY SURFACE FEATURE (RIM, GRATE, INLET STRUCTURE, OUTLET STRUCTURE, CURB, GUTTER, OR OTHER) AS REQUIRED BY NEW CONSTRUCTION OR
GRADING. THIS WORK SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
5. EXCAVATION AND DISPOSAL OF ALL TREES, BRANCHES, LIMBS, AND BRUSH, DEMOLITION DEBRIS, TRENCH SPOILS, ROCK, PAVEMENT MATERIALS (CONCRETE OR ASPHALT), OR OTHER WASTE MATERIALS SHALL BE
DONE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL LAWS AND CODES.
6. ALL DEWATERING COSTS ASSOCIATED WITH THE INSTALLATION AND CONSTRUCTION OF THE UNDERGROUND UTILITIES; STORM WATER PIPES AND MANHOLES; SANITARY SEWER MAINS; AND MANHOLES; AND STORM WATER MANAGEMENT SYSTEMS SHALL BE INCLUDED AS PART OF THE CONSTRUCTION BID COSTS. ALL PIPES SHALL HAVE 3 FEET MINIMUM COVER UNLESS OTHERWISE SPECIFIED IN PLANS. CONTRACTOR SHALL TAKE
CARE TO PROVIDE PROPER GRADE ELEVATIONS AND ALIGNMENTS.
EXISTING UTILITIES
1. THE LOCATION OF EXISTING UTILITIES AND STORM DRAINAGE INFRASTRUCTURE SHOWN ON THE PLANS HAS BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND IS GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE OWNER AND ENGINEER ASSUME NO RESPONSIBILITY FOR THE ACCURACY OF THIS
INFORMATION. INDIVIDUAL SERVICE LINES ARE NOT SHOWN.
2. THE CONTRACTOR OR SUBCONTRACTOR SHALL NOTIFY THE OHIO UNDERGROUND PROTECTION (811) FORTY-EIGHT (48) HOURS IN ADVANCE OF ANY CONSTRUCTION ON THIS PROJECT. CONTRACTOR IS CAUTIONED THAT SOME UTILITIES ARE NOT MEMBERS OF OHIO UNDERGROUND PROTECTION AND PRIVATE UTILITIES ARE NOT LOCATED BY OHIO UNDERGROUND PROTECTION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR MAINTAINING ACTIVE OHIO UNDERGROUND PROTECTION MARKINGS.
3. RESTORATION OR REPAIR OF ANY DISTURBED OR DAMAGED UTILITY OR STORMWATER INFRASTRUCTURE, WHETHER LOCATED BY OHIO UNDERGROUND PROTECTION OR NOT, SHALL BE AT THE CONTRACTOR'S
EXPENSE.
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE UTILITIES WITH THE OWNER OF THE UTILITY.
THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES WHETHER SHOWN ON THE PLAN OR LOCATED BY OHIO UNDERGROUND PROTECTION OR THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE BROUGHT TO THE ATTENTION OF THE OHANG PRIOR TO INITIATION OF CONSTRUCTION. ANY FEES ASSOCIATED WITH UTILITY RELOCATIONS SHALL BE BORNE BY THE CONTRACTOR IN ACCORDANCE WITH RESPECTIVE UTILITY COMPANY STANDARDS. ANY DELAY OR INCONVENIENCE CAUSED BY THE RELOCATION OF THE VARIOUS UTILITIES SHALL BE INCIDENTAL
TO THE CONTRACT.
5. A MINIMUM SEPARATION OF TWENTY-FOUR (24) VERTICAL INCHES IS REQUIRED AT ANY LOCATION WHERE A WATERLINE CROSSES A SANITARY SEWER LINE. IF THIS SEPARATION CANNOT FEASIBLY BE OBTAINED, THE LOWER OF THE TWO PIPES SHALL BE WRAPPED IN POLYETHYLENE AND ENCASED IN CONCRETE FIVE FEET
EACH SIDE OF CROSSING.
6. DUCTILE IRON PIPE SHALL BE ENCASED IN POLYETHYLENE TWENTY-FIVE (25) FEET ON EACH SIDE OF ANY PERPENDICULAR CROSSING OF A METALLIC GAS MAIN, OR WHEN PARALLEL TO AND WITHIN TEN FEET OF A METALLIC GAS MAIN OR OTHER CATHODICALLY PROTECTED PIPE, OR WHEN THE DUCTILE IRON PIPE IS IN THE
AREA OF INFLUENCE OF A CATHODIC PROTECTION ANODE BED.
GENERAL:
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL REQUIRED PERMITS ARE OBTAINED BEFORE BEGINNING ANY CONSTRUCTION. NO CONSTRUCTION OR FABRICATION OF ANY ITEM SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED ALL PLANS AND ANY OTHER DOCUMENTATION FROM ALL OF THE PERMITTING AND ANY OTHER REGULATORY AUTHORITIES. ANY PENALTIES, STOP WORK ORDERS OR ADDITIONAL WORK RESULTING FROM THE CONTRACTOR BEING IN VIOLATION OF THE REQUIREMENTS
ABOVE, SHALL BE FULLY BORNE BY THE CONTRACTOR.
2. THE SEQUENCE OF CONSTRUCTION SHALL BE SUCH THAT ALL UNDERGROUND INSTALLATIONS OF EVERY KIND, SHALL BE PLACED BENEATH THE PAVEMENT AND ITS EDGES PRIOR TO THE CONSTRUCTION OF THE PAVEMENT. THE PAVEMENT SHALL NOT BE CUT WITHOUT PRIOR APPROVAL OF THE CONTRACTING OFFICER.
3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE EXISTING SITE CONDITIONS OF SOIL PRIOR TO ISSUING OF THE NOTICE TO PROCEED, TO DETERMINE IF ANY OFF SITE MATERIALS WILL NEED TO BE
IMPORTED TO ACHIEVE THE GRADES SPECIFIED ON THE DRAWINGS.
4. ALL EXCESS SPOILS FROM SITE SHALL BE STOCKPILED BY THE CONTRACTOR.
5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COMPLETE WORK ON DRAWINGS AND THE APPROPRIATE SPECIFICATIONS AS A UNIT. ANY OMISSIONS, DELETIONS, OR CONFLICTS ARISING AS A RESULT OF FAILURE TO INCORPORATE ALL DRAWINGS AND SPECIFICATIONS WHICH APPLY SHALL BE CORRECTED BY
THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER AND/OR COR.
6. ALL TREE CLEARING AND TREE DISPOSAL WITHIN THE LIMITS OF DISTURBANCE SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
7. THE CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN TO THE OHANG FOR REVIEW. TRAFFIC
CONTROL MEASURES SHALL BE INCLUDED IN THE TRAFFIC CONTROL PLAN.
8. ALL PIPES SHALL BE TESTED PRIOR TO BEING ENCASED IN CONCRETE OR A THRUST BLOCK.
9. CONTRACTOR SHALL PROVIDE TEMPORARY RESTROOMS FOR ALL EMPLOYEES.
10. A MINIMUM 10-FOOT HORIZONTAL SEPARATION AND TWENTY-FOUR (24)-INCH VERTICAL SEPARATION MUST BE
MAINTAINED BETWEEN A POTABLE WATER LINE AND ANY OTHER PIPING.
11. ALL COORDINATES PROVIDED ON THE STRUCTURAL COORDINATE TABLES ARE GIVEN AT THE PROPOSED
GROUND LEVEL.
EARTHWORK, GRADING, STABILIZATION, PAVING AND DRAINAGE:
1. TOPSOIL IN AREAS OF EXCAVATION SHALL BE STRIPPED AND SEPARATELY STOCKPILED ON SITE FOR
FINISH LANDSCAPING AND/OR GRADING USE ONLY.
2. ALL DITCHES TO TOP OF BANK SHALL BE ARMORED WITH EROSION CONTROL BLANKET UNTIL SOD IS
PLACED, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
3. THE CONTRACTOR SHALL STOCKPILE ALL TOPSOIL DURING CONSTRUCTION FOR PLACEMENT ON THE
SPOILS PILE AND REUSE ON-SITE.
4. ALL EROSION AND SEDIMENT CONTROL MEASURES SHOWN ARE A MINIMUM ONLY. IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO MEET ALL REQUIREMENTS OF OH EPA NPDES PERMIT.
PERMIT REQUIREMENTS:
1. SEDIMENT AND EROSION CONTROL MEASURES, SUCH AS CHECK-DAMS CONSTRUCTED OF ANY MATERIAL, SILT FENCING, HAY BALES, ETC. SHALL NOT BE PLACED WITHIN SURFACE WATERS, EITHER TEMPORARILY OR PERMANENTLY, WITHOUT PRIOR APPROVAL BY THE OHIO DEPARTMENT OF ENVIRONMENTAL MANAGEMENT.
ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE REMOVED AND NATURAL GRADE RESTORED WITHIN
THE COMPLETION TIMELINE OF THE ACTIVITIES.
J
PO
LL
M
AN
J
BE
AN
R P
EA
R
SO
N
D M
O
TL
EY
C
ER
TI
FI
ED
F
IN
AL
M
AY
3, M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N
LZ
G
C
ER
TI
FI
ED
F
IN
AL
D
C M
SHEET ID
D
ES
IG
N
B Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SU
BM
IT
TE
D B
Y:
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
D
R M
AR
TI
N L
U
TH
ER
J
R P
L
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
A
RI
CK
EN
BA
CK
ER
IN
TE
RN
AT
IO
NA
L A
IR
PO
RT
(A
NG
OH
IO
OH
IO
A
IR
N
AT
IO
NA
L G
UA
RD
AN
G
SM
AL
L A
RM
S
RA
NG
E
P 2#
CI
VI
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
B
C
D
E
F
G
H
J
K
L
M
N
P
Fi le
P at h:
Pl ot D at e:
US Army Corps of Engineers ®
IS
SU
E D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
SI
ZE
AN
SI
D
. . PR
O
JE
C
T N
O
PRELIMINARY
NOT FOR
CONSTRUCTION
PROJECT SPECIFIC NOTESPROJECT GENERAL NOTES
UTILITY CONTACT INFORMATION
ELECTRIC -
SOUTH CENTRAL POWER COMPANY
720 MILL PARK DRIVE
LANCASTER, OH 43130-7933
P.O.BOX 182058
COLUMBUS, OH 43218-2058
PHONE 1.800.282.5064
GAS-
COLUMBIA GAS OF OHIO
P.O.BOX 2318
COLUMBUS, OH 43216-2318
CUSTOMER SERVICE 1.800.344.4077
WATER & SEWER
THE CITY OF COLUMBUS
DEPARTMENT OF PUBLIC UTILITIES
910 DUBLIN RD.
COLUMBUS, OH 43215-1169
CUSTOMER SERVICE 614.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .