W912QR24R0011_Specs-0001.pdf
PDF 1 MB Posted
- Solicitation number
- W912QR24R0011
About this file
This is a summary of a federal contract solicitation for the construction of an Army Reserve Center and associated facilities in Asheville, North Carolina. The U.S. Army Corps of Engineers Louisville District intends to issue a request for proposal for construction services including an insulated concrete form Army Reserve Center totaling 31,637 square feet, a vehicle maintenance shop of insulated concrete forming totaling 9,781 square feet, and a 1,500 square foot pre-engineered metal unheated storage building. Additional site work will include utilities, paving, parking, and landscaping. The contract will be a firm-fixed-price design-bid-build delivery method with a duration of 720 calendar days from notice to proceed. The North American Industry Classification System code is 236220 and there is no set-aside designated. Proposals will be evaluated using best value tradeoff with evaluation factors including past performance, management plan, and price. Discussions may be held but award is intended without discussions.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Solicitation W912QR24R0011 for Construction of an Army Reserve Center (ARC), Vehicle Maintenance Facility, and Organizational Storage Building in Asheville, North Carolina is hereby amended as follows:
See Continuation Page.
1. CONTRACT ID CODE PAGE OF PAGES
1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912QR24R0011
X 9B. DATED (SEE ITEM 11)
07-Feb-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
U0001
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3.EFFECTIVE DATE
05 - Mar-2024
CODE
U. S. ARMY ENGINEER DISTRICT, LOUISVILLE
600 DR. MARTIN LUTHER KING, JR. PLACE
ROOM 821
LOUISVILLE KY 40202-2239
W912QR 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912QR24R0011_Specs-0001
W912QR24R0011
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been added by full text:
AMDT 0001 CONTINUATION PAGE
a. The folling SPECIFICATION SECTIONS have been replaced in their entirety:
1) 10 90 00.00 48 MISCELLENEOUS SPECIALTIES (PARTIAL OMAR FUNDED)
2) 06 20 00 FINISH CARPENTRY
b. The following DRAWINGS have been replaced in their entirety:
CS101 Revised note “V. SITE COVERAGE” in lower left corner. (Grid A1). This is a City of Hendersonville Zoning Requirement.
CS502 Revised Detail 8 (Curb & Gutter) to match standard NCDOT 846.01 1’ – 6” Detail.
Included 6” of graded aggregate base to detail.
CU112 Included backflow preventer with hot box on domestic water service.
CU406 Sheet note 13. Included backflow preventer with hot box on domestic water service.
CU514 Included note for Detail 1 regarding the Backflow Prevention Assembly.
ES002 Updated utility contact information.
ES101 Updated to accommodate backflow preventer hot box requirements.
ES502 Added sheet in its entirety.
1A—420 Revised detail 4 and key notes.
1A—800 Revised section A, and key notes.
1EP111 Updated receptacle layout and circuiting.
1EP702 Updated panel schedule.
1EP705 Updated panel schedule.
c. Proposal due date revised to 19 March 2024 at 2:00 PM Eastern Time.
W912QR24R0011
d. All other terms and conditions remain unchanged.
SECTION 00 10 00 - SOLICITATION
The required response date/time has changed from 12-Mar-2024 02:00 PM to 19-Mar-2024 02:00 PM.
(End of Summary of Changes)
P2#: 481815 Asheville USARC Asheville, North Carolina
SECTION 06 20 00
FINISH CARPENTRY
08/16, CHG 2: 11/18
Amendment 0001
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN HARDBOARD ASSOCIATION (AHA)
AHA A135.4 (1995; R 2004) Basic Hardboard
AMERICAN LUMBER STANDARDS COMMITTEE (ALSC)
ALSC PS 20 (2015) American Softwood Lumber Standard
AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
ASME B18.2.1 (2012; Errata 2013) Square and Hex Bolts and Screws (Inch Series)
ASME B18.2.2 (2015) Nuts for General Applications:
Machine Screw Nuts, Hex, Square, Hex Flange, and Coupling Nuts (Inch Series)
ASME B18.6.1 (2016) Wood Screws (Inch Series)
AMERICAN WOOD PROTECTION ASSOCIATION (AWPA)
AWPA U1 (2021) Use Category System: User Specification for Treated Wood
APA - THE ENGINEERED WOOD ASSOCIATION (APA)
APA L870 (2010) Voluntary Product Standard, PS 1-09, Structural Plywood
ASTM INTERNATIONAL (ASTM)
Amendment 0001****************************************************
ASTM A167 (2011) Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip
****************************************************Amendment 0001
ASTM F547 (2017) Standard Terminology of Nails for Use with Wood and Wood-Base Materials
SECTION 06 20 00 Page 1 AMENDMENT 0001 - Certified Final
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.9 (2020) Cabinet Hardware
CALIFORNIA AIR RESOURCES BOARD (CARB)
CARB 93120 (2007) Airborne Toxic Control Measure (ATCM) to Reduce Formaldehyde Emissions from Composite Wood Products
FOREST STEWARDSHIP COUNCIL (FSC)
FSC STD 01 001 (2015) Principles and Criteria for Forest Stewardship
HARDWOOD PLYWOOD AND VENEER ASSOCIATION (HPVA)
HPVA HP-1 (2016) American National Standard for Hardwood and Decorative Plywood
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates
NATIONAL HARDWOOD LUMBER ASSOCIATION (NHLA)
NHLA Rules (2015) Rules for the Measurement & Inspection of Hardwood & Cypress
NORTHEASTERN LUMBER MANUFACTURERS ASSOCIATION (NELMA)
NELMA Grading Rules (2013) Standard Grading Rules for Northeastern Lumber
REDWOOD INSPECTION SERVICE (RIS) OF THE CALIFORNIA REDWOOD
ASSOCIATION (CRA)
RIS Grade Use (1998) Redwood Lumber Grades and Uses
SOUTHERN PINE INSPECTION BUREAU (SPIB)
SPIB 1003 (2014) Standard Grading Rules for Southern Pine Lumber
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
40 CFR 770 Formaldehyde Standards for Composite Wood Products
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings
WEST COAST LUMBER INSPECTION BUREAU (WCLIB)
WCLIB 17 (2015) Standard Grading Rules
SECTION 06 20 00 Page 2
WESTERN WOOD PRODUCTS ASSOCIATION (WWPA)
WWPA G-5 (2017) Western Lumber Grading Rules
WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)
WDMA I.S.4 (2015A) Preservative Treatment for Millwork
WOODWORK INSTITUTE (WI)
NAAWS 3.1 (2017; 2018 Errata Edition) North American Architectural Woodwork Standards
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submittals with an "S" are for inclusion in the Sustainability eNotebook, inconformance with Section 01 33 29.00 06 SUSTAINABILITY REPORTING.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Amendment 0001****************************************************
Detail Drawings Indicating All Wood Assemblies including countertops and wall caps ; G
****************************************************Amendment 0001
SD-03 Product Data
Wood Products ; G
Countertops ; G
Amendment 0001****************************************************
Treated Wood Products ; G
Fascias and Trim ; G
Hardware and Accessories ; G
****************************************************Amendment 0001
SD-04 Samples
Samples ; G
SD-07 Certificates
Indoor Air Quality for Hardwood Plywood ; S
SECTION 06 20 00 Page 3
1.3 DETAIL DRAWINGS
Submit detail drawings indicating all wood assemblies proposed for use in the project. Indicate materials, species, grade, density, grain, finish details of construction, location of use in the project, finishes, types, method and arrangement of fasteners, and installation details. This includes all fabricated assemblies.
1.4 PRODUCT DATA
Submit Manufacturers printed data including proposed species, grade, density grain, and finish as applicable; sufficient to demonstrate compliance with this specification for each type of wood product specified. For treated wood products also provide documentation of environmentally safe preservatives for each type of wood product specified.
Provide Manufacturers printed data for hardware and all wood accessories including but not limited to edge banding, adhesives, and sealers.
1.5 SAMPLES
Samples indicating proposed species, grade, density grain, and finish for each type of wood product specified. Provide samples of sufficient size to show pattern and color ranges of proposed products.
1.6 DELIVERY, STORAGE, AND HANDLING
Deliver wood products to the jobsite in an undamaged condition. Stack materials to ensure ventilation and drainage. Protect against dampness before and after delivery. Store materials under cover in a well ventilated enclosure and protect against extreme changes in temperature and humidity. Keep materials wrapped and separated from off-gassing materials (such as drying paints and adhesives). Do not use materials that have visible moisture or biological growth. Do not store products in building until wet trade materials are dry and humidity of the space is within wood manufacturer's tolerance limits for storage.
1.7 QUALITY ASSURANCE
1.7.1 Certifications
1.7.1.1 Certified Sustainably Harvested Wood
Provide wood certified as sustainably harvested by FSC STD 01 001 .
Provide a letter of Certification of Sustainably Harvested Wood signed by the wood supplier. Identify certifying organization and their third party program name and indicate compliance with chain-of-custody program requirements. Submit sustainable wood certification data; identify each certified product on a line item basis. Submit copies of invoices bearing certification numbers.
1.7.1.2 Indoor Air Quality Certifications
1.7.1.2.1 Adhesives and Sealants
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party programs that products meet the requirements of this Section. Provide current product
SECTION 06 20 00 Page 4 certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.
1.7.1.2.2 Composite Wood Products
For purposes of this specification, composite wood products include hardwood plywood, particleboard, medium density fiberboard (MDF), panel substrates, and door cores. Provide products certified to meet requirements of both 40 CFR 770 and CARB 93120 . Provide current product certification documentation from certification body.
1.7.2 Lumber
Identify each piece or each bundle of lumber, millwork, and trim by the grade mark of a recognized association or independent inspection agency certified by the Board of Review of the ALSC to grade the species.
1.7.3 Plywood
Provide each sheet of plywood with the mark of a recognized association or independent inspection agency that maintains continuing control over the quality of the plywood. Marks must identify plywood by species group or span rating, exposure durability classification, grade, and compliance with APA L870 .
1.7.4 Hardboard
Provide materials marks or written documentation identifying the producer and the applicable standard.
1.7.5 Pressure Treated Lumber and Plywood
Inspect each treated piece in accordance with AWPA U1.
1.7.6 Non-Pressure Treated Woodwork and Millwork
Mark, stamp, or label to indicate compliance with WDMA I.S.4 .
1.7.7 Fire-Retardant Treated Lumber
Each piece must bear an Underwriters Laboratories fire resistance label or comparable label of another nationally recognized independent fire retardant materials testing laboratory.
PART 2 PRODUCTS
2.1 WOOD PRODUCTS
2.1.1 Sizes and Patterns of Wood Products
Provide yard and board lumber sizes in accordance with ALSC PS 20 .
Provide shaped lumber and millwork in the patterns indicated and in standard patterns of the association covering the species. Size references, unless otherwise specified, are nominal sizes. Provide actual sizes within manufacturing tolerances allowed by the applicable standard.
SECTION 06 20 00 Page 5
2.1.2 Species and Grades
Provide in accordance with AWPA U1 Use Category System Tables unless otherwise specified herein.
2.1.3 Trim, Finish, and Frames
Provide species and grades listed in the table below for wood materials that must be painted. For materials that must be stained, have a natural, or a transparent finish, provide materials one grade higher than those listed in the table below. Provide trim, except window stools and aprons with hollow backs.
TABLE OF GRADES FOR WOOD TO RECEIVE PAINT FINISH
Grading Rules Species Exterior and Interior Trim, Finis h, and Frames
WWPA G-5 standard grading rules
Aspen, Douglas Fir-Larch, Douglas Fir South, Engelmann Spruce-Lodgepole Pine, Engelmann Spruce, Hem-Fir, Idaho White P ine, Lodgepole Pine, Mountain Hemlock, Mountain Hemlock-Hem-Fir, Ponderosa Pine-Sugar Pine, (Ponderosa Pine-Lodgepole Pine,) White Woods, (Western Woods, ) Western Cedars, Western Hemlock
All Species: C & BTR. Select (Ch oice & BTR Idaho White Pine) or Superior Finish.
Western Red Cedar may be graded C & BTR. Select or A & BTR in accordance with Special Western Red Cedar Rules.
WCLIB 17 standard grading rules
Douglas Fir-Larch, Hem-Fir, Mountain Hemlock, Sitka Spruce, Western Cedars, Western Hemlock
All Species: C & BTR VG, except A for Western Red Cedar
SPIB 1003 standard grading rules
Southern Pine C & BTR
NHLA Rules Cypress C-Select
NELMA Grading Rules standard grad ing rules **
Balsam Fir, Eastern Hemlock-Tamar ack, Eastern Spruce, Eastern White Pine, Northern Pine, Northern Pin e, Northern White Cedar
All Species: C-Select except C & BTR for Eastern White Pine and Norway Pine
SECTION 06 20 00 Page 6
TABLE OF GRADES FOR WOOD TO RECEIVE PAINT FINISH
Grading Rules Species Exterior and Interior Trim, Finis h, and Frames
RIS Grade Use st andard specifications
Redwood Clear, Clear All Heart
NHLA Rules Cypress B Finish
Red Gum, Soft Elm, Birch Select or BTR (for interior use o nly)
Note: ** http://www.nelma.org/library/2013-standard-grading-rules-for-northeastern-lumber/
2.1.4 Softwood Plywood
Provide in accordance with APA L870 . When located on the interior of buildings, provide products with no added urea-formaldehyde resins.
a. Plywood for Countertops: Exterior type, A-C Grade.
2.1.5 Hardwood Plywood
HPVA HP-1 , Type II (Interior) , Good (1) Grade, hardwood veneer core construction, face veneers of , of thickness indicated. When located on the interior of buildings, provide products with no added urea-formaldehyde resins. For products located on the interior of the building (inside of the weatherproofing system), provide certification of indoor air quality for hardwood plywood .
2.1.6 Hardboard
AHA A135.4 , standard type.
2.2 FASCIAS AND TRIM
2.2.1 Wood
Provide species and grades for all fascia and trim, including exterior door and window casings, in accordance with AWPA U1 Use Category System Tables. Provide sizes indicated. If metal corners are used, provide galvanized steel or aluminum, completely coated with primer compatible for the specific metal substrate.
2.3 COUNTERTOPS
2.3.1 Laminated Plastic-faced Countertops
ANSI/NEMA LD 3 .
SECTION 06 20 00 Page 7
2.3.1.1 Countertop Finishes
High pressure plastic laminate, Grade GP 50 or PF 42, satin or textured finish.
2.3.1.2 Backing Sheet
Heavy gauge, BK 20.
2.3.2 Solid Surface
For solid surface countertops refer to Section 06 61 16 , SOLID POLYMER
(SOLID SURFACING) FABRICATIONS.
Amendment 0001****************************************************
2.3.3 Stainless Steel Countertops and Wall Caps
Fabricate stainless steel items of 18 gauge thick material conforming to ASTM A167, Grade 304, fully welded as necessary, seamless, and polished to a #4 commercial finish.
****************************************************Amendment 0001
2.4 MOISTURE CONTENT OF WOOD PRODUCTS
Air dry or kiln dry lumber. Kiln dry treated lumber after treatment.
Maximum moisture content of wood products at time of delivery to the jobsite, and when installed, must be as follows:
a. Interior Paneling: 6 percent.
b. Interior Finish Lumber, Trim, and Millwork: 1-1/4 Inches Nominal or Less in Thickness: 6 percent on 85 percent of the pieces and 8 percent on remainder. c. Provide moisture content of other materials in accordance with the applicable standards.
2.5 HARDWARE AND ACCESSORIES
Provide sizes, types, and spacings of hardware and accessories as recommended in writing by the wood product manufacturer, except as otherwise specified.
2.5.1 Wood Screws
ASME B18.6.1 .
2.5.2 Bolts, Nuts, Lag Screws, and Studs
ASME B18.2.1 and ASME B18.2.2 .
2.5.3 Nails
Use nails of a size and type best suited for each application and in accordance with ASTM F547. Use hot-dipped galvanized or aluminum nails for exterior applications. For siding, provide nails of sufficient length to extend 1-1/2 inches into supports, including wood sheathing over framing. Where nailing is impractical, provide screws of a size and type best suited for each application.
SECTION 06 20 00 Page 8
2.5.4 Vertical Slotted Shelf Standards
ANSI/BHMA A156.9 , Type B04102 , with shelf brackets Type B04102 .
2.6 FABRICATION
2.6.1 Quality Standards (QS)
2.6.1.1 Grades
The terms "Premium," "Custom," and "Economy" refer to the quality grades defined in NAAWS 3.1. Provide items not otherwise specified in a specific grade as "Custom" grade.
2.6.1.2 Adhesives
Select adhesives for durability and permanent bonding. Address factors such as materials that must be bonded, expansion and contraction, bond strength, fire rating, moisture resistance, and manufacturer's recommendations.
2.6.2 Countertops
Fabricate with lumber and a core of exterior plywood , glued and screwed to form an integral unit.
2.6.3 Cabinets
Fabricate cabinets with solid ends and frame fronts, or with frames all around. Provide frames of solid hardwood not less than 3/4 by 1-1/2 inches .
Provide ends, bottoms, backs, partitions, and doors as hardwood plywood.
Mortise and tenon, dovetail, or dowel and glue joints to produce a rigid unit. Cover exposed edges of plywood with hardwood strips. Provide cabinet doors, frames, and solid exposed ends 3/4 inch thick minimum.
Provide cabinet bottoms, partitions, and framed ends to be 1/2 inch minimum. Provide shelves to be 5/8 inch thick minimum. Provide cabinet backs 1/4 inch thick minimum.
2.6.3.1 Cabinet Hardware
ANSI/BHMA A156.9 . Provide cabinet hardware including two self, closing hinges for each door, two side mounted metal drawer slides for each drawer, and pulls for all doors and drawers .
2.6.3.2 Finish
Provide a clear factory finish on wood surfaces after fabrication. Provide fabricator's standard natural finish equivalent to one coat of sealer, one coat of varnish on all surfaces and a second coat of varnish on surfaces exposed to view. Provide spar varnish in exterior or wet area applications. Sand lightly and wipe clean between coats.
2.6.4 Workbenches
Dovetail and glue drawer corners. Fasten frames with suitable wood screws or bolts. Sand exposed surfaces smooth, and ease exposed edges.
SECTION 06 20 00 Page 9
2.6.5 Casework with Transparent Finish (CTF)
2.6.5.1 AWI Quality Grade
Custom grade.
2.6.5.2 Construction
Provide flush overlay design details.
2.6.5.3 Exposed Parts
Birch specie s, rotary cut.
2.6.5.4 Semi-Exposed Parts
As specified in the NAAWS 3.1 for the grade selected.
2.6.6 Casework with High Pressure Laminate Finish
2.6.6.1 AWI Quality Grade
Custom grade.
2.6.6.2 Construction
Provide flush overlay design details.
2.6.6.3 Exposed Surfaces
High pressure plastic laminate, color and pattern as shown on drawings .
2.6.6.4 Semi-Exposed Surfaces
As specified in the NAAWS 3.1 for the grade selected.
PART 3 EXECUTION
Do not install building construction materials that show visual evidence of biological growth.
3.1 FINISH WORK
Apply primer to finish work before installing. Where practicable, shop assemble and finish millwork items. Construct joints tight and in a manner to conceal shrinkage but to avoid cupping, twisting and warping after installation. Miter trim and mouldings at exterior angles; cope at interior angles and at returns. Provide millwork and trim in maximum practical lengths. Fasten finish work with finish nails. Provide blind nailing where practicable. Set face nails for putty stopping.
3.1.1 Exterior Finish Work
Machine sand exposed flat members and square edges. Machine finish semi-exposed surfaces. Construct joints to exclude water. In addition to nailing, glue joints with waterproof glue as necessary for weather resistant construction. Evenly distribute end joints in built-up members. Provide shoulder joints in flat work. Reinforce backs of wide-faced miters with metal rings and waterproof glue. Unless otherwise
SECTION 06 20 00 Page 10 indicated, provide fascia and other flat members 3/4 inch thick minimum.
Provide door and window trim in single lengths. Provide braced, blocked, and rigidly anchored cornices for support and protection of vertical joints. Provide soffits in largest practical size. Align joints of plywood over centerlines of supports. Fasten soffits with aluminum or stainless steel nails. Back prime all concealed surfaces of exterior trim.
3.1.2 Interior Finish Work
After installation, sand exposed surfaces smooth. Provide window and door trim in single lengths.
3.1.3 Door Frames
Set plumb and square. Provide solid blocking at not more than 16 inches on center for each jamb. Position blocking to occur behind hinges and lock strikes. Double wedge frames and fasten with finish nails. Set nails for putty stopping.
3.1.4 Thresholds
Unless otherwise indicated, provide thresholds 5/8 inch thick by 2-5/8 inches wide with beveled sides and cut to fit at jambs. Fasten thresholds with casing nails. Set nails for putty stopping.
3.1.5 Window Stools and Aprons
Provide stools with rabbets over window sills. Provide aprons with returns cut accurately to profile of member.
3.1.6 Bases
Provide flat member with a moulded top . Fasten base to framing or to grounds. Set after finish flooring is in place.
3.2 MISCELLANEOUS
Amendment 0001****************************************************
3.2.1 Countertops and Wall Caps
****************************************************Amendment 0001
Conceal fastenings where practicable. Fit counters tight to adjoining surfaces and scribe where necessary. Provide scribed joints neat and flush. Provide counter sections in longest lengths practicable with a minimum number of joints. Where joints are necessary, provide tight joints drawn up with concealed type heavy pull-up bolts. Glue joints with water resistant glue and make rigid with screws, bolts, or other approved fastenings.
3.2.2 Cabinets
Provide cabinets level, plumb, true, and tight to adjacent walls. Secure cabinets to walls with concealed toggle bolts. Secure top to cabinet with concealed screws. Make cutouts for fixtures from templates supplied by fixture manufacturer. Locate cutouts for pipes so that edges of holes are covered by escutcheons after installation.
SECTION 06 20 00 Page 11
3.2.3 Workbenches
Provide level, plumb, and tight to adjacent construction. Fasten workbenches to walls with screws or toggle bolts and to floors with expansion bolts.
3.3 MOULDING AND INTERIOR TRIM
Install mouldings and interior trim straight, plumb, level and with closely fitted joints. Provide exposed surfaces machine sanded at the shop. Cope returns and interior angles at moulded items and miter external corners. Shoulder intersections of flatwork to ease any inherent changes in plane. Provide window and door trim in single lengths. Blind nail to the extent practicable. Set and stop face nailing with a nonstaining putty to match the applied finish. Use screws for attachment to metal; set and stop screws in accordance with the same quality requirements for nails.
-- End of Section --
SECTION 06 20 00 Page 12
SECTION 10 90 00.00 48
MISCELLANEOUS SPECIALTIES (PARTIAL OMAR FUNDED)
04/06
Amendment 0001
PART 1 GENERAL
1.1 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Mail Boxes ; FIO
Wash Bay Curtain; FIO
Drawings showing construction and installation details.
SD-03 Product Data
Product certification and installation recommendation data.
Acceptable Manufacturer Products ; FIO
Refrigerator ; G
Microwave ; G
Amendment 0001*****************************************************
Compact Refrigerator ; G
*****************************************************Amendment 0001
Trash and Ash ; G
Hat and Coat Racks ; G
Recycling Center ; G
Wash Bay Curtain ; G
Ballet Rail ; G
Floor Mats ; G
Letter Drop (Same manufacturer as mail boxes.)
Mail Boxes : See Section 09 06 90 COLOR SCHEDULE; FIO
SECTION 10 90 00.00 48 Page 1
Mail Box ; G
Security Mesh ; FIO
Provide data describing security mesh installation and recommendations.
Mooring Eye Casting ; FIO
Mooring Eye ; G
SD-04 Samples
Color Charts ; FIO
Submit color chart for mailbox.
1.2 DELIVERY AND STORAGE
All items shall be delivered to the project site in manufacturer's undamaged containers.
1.3 WARRANTY
Provide manufacturer's standard warranty for the items.
PART 2 PRODUCTS
2.1 MAILBOXES
2.1.1 General
Mailboxes shall be U.S. Postal Service approved. Mailboxes, materials, sizes, construction, and installation shall comply with U.S. Postal Service regulations and shall be fully approved by the U.S. Postal Service.
2.1.2 Materials
Quantities and arrangement of mailboxes shall be as indicated on the drawings. Mailboxes shall be rear-loading type with sheet aluminum rear door with a continuous piano hinge on one side and a keyed lock on the other side strengthened with formed sheet aluminum stiffeners. Framework supporting compartment doors shall be fabricated from high strength extruded aluminum alloy. Compartment doors shall be fabricated from high strength extruded aluminum alloy, with a minimum of 3.2 mm thickness, and swing on concealed hinge pins. The compartment door shall be double wide to accept minimum 8.5" x 11" size mail without bending. When closed, the door shall interlock with frame member along hinge side and shall be precision fitted to preclude prying. Doors shall be reinforced vertically along both sides and near center with integral ribs. Locks on individual compartment doors shall be springlatch type lock actuated by a cam type lock with two change keys per lock and a minimum of 1000 available key changes. All locks within project shall be keyed differently.
Compartment construction shall be double-walled high strength sheet aluminum alloy with vertical stiffeners of formed aluminum. Finish shall be as indicated on the drawings. Mail box manufacturer shall furnish aluminum channel type cardholders with pressure sensitive backing to accommodate 7/16" by 2 1/2 inch cards for individual and/or unit names.
SECTION 10 90 00.00 48 Page 2
Provide spring hinged front door letter drop with finish to match mail boxes . Door shall have engraved "Mail Drop". Minimum size of 5" high x 12 5/8" wide. Provide wall liner secured to letter drop.
2.1.3 Color
Color shall be in accordance with Section 09915 COLOR SCHEDULE.
2.2 SECURITY MESH
Security mesh shall be a minimum of (8) .025 plain steel mesh 1/16" thick and weigh a minimum of .75 pounds per square foot. The mesh shall be diamond type with a minimum of 73 percent open area. The overall mesh size and orientation shall be as recommended by the manufacturer.
2.3 MOORING EYE
Mooring eye shall be a standard casting product constructed of ductile iron and made to be installed in concrete with top of casting flush with top of finish concrete.
2.3.1 Trash and Ash (OMAR Funded)
Freestanding trash receptacle and metal finish bucket flap top, 10 inch diameter by 28 inches high. Color "Graphite" as selected from manufacturer's standard colors.
2.3.2 Hat and Coat Racks
Wall mounted two prong polished aluminum coat hooks with plastic laminate or finshed wood unit.
Amendment 0001*****************************************************
2.3.3 DELETED
*****************************************************Amendment 0001
2.3.4 Recycling Bin (OMAR Funded)
Trash container shall be molded rubber with hinged lid, 60 gal capacity, 2 heavy duty wheels for mobility.
Amendment 0001*****************************************************
2.3.5 DELETED
*****************************************************Amendment 0001
2.3.6 Floor Mats
Recessed door entrance mats shall be coordinated with carpet specification.
2.3.7 Ballet Rail
Wall mounted fixed Ballet Barre bracket shall be of 1/4 inch steel plate approximately 1 x 5 1/2inch with two mounting holes for screws, fixed rail extension stud shall extend out 9 inches, finish shall be of chrome. Wood
SECTION 10 90 00.00 48 Page 3 rail shall be 1 - 1/ 2 inch diameter, length as indicated on the drawings.
Amendment 0001*****************************************************
2.3.8 DELETED
*****************************************************Amendment 0001
2.3.9 Refrigerator
UL 250, refrigerator with frostproof top freezer, minimum 20 cubic feet, automatic defrosting, two vegetable bottom baskets, two door shelves and minimum 12 egg container in the door, separate interior shelves, multiple door shelves, and door mounted ice and water dispencer. Provide reversible left and right swing doors. Provide four fixed rollers or adjustable leg levelers. Refrigerator shall be white.
2.3.10 Microwave
UL 923, with black glass window door, minimum 1.5 cubic feet capacity, automatic oven light, browning element, 10 power levels, automatic temperature controls, minimum two automatic memory levels, digital time controllers, and electronic touch-control panel. Microwave shall be white.
Amendment 0001*****************************************************
2.3.11 Compact Refrigerator
Compact Refrigerator with frost proof freezer compartment , minimum 4.5 cubic feet, automatic defrosting, minimum one door shelf, and separate interior shelves. Provide reversible left and right swing doors. Provide four fixed rollers or adjustable leg levelers. Refrigerator shall be white.
*****************************************************Amendment 0001
PART 3 EXECUTION
3.1 INSTALLATION
Install all items in strict accordance with manufacturer's recommendations at the locations indicated on the drawings. Align and plumb all items with adjacent surfaces and set accurately in location.
3.2 PROTECTION AND CLEANING
Protect the work from other trades and remove all protective wrappings when appropriate. Clean all surfaces in accordance with manufacturer's recommendations.
3.3 INSTALLATION OF KITCHEN EQUIPMENT
Install kitchen equipment in accordance with manufacturers' instructions and NFPA 70.
-- End of Section --
SECTION 10 90 00.00 48 Page 4
| SF30 |
| SUMMARY OF CHANGES |
| 06 20 00 |
| 06 20 00 - FINISH CARPENTRY |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 DETAIL DRAWINGS |
| 1.4 PRODUCT DATA |
| 1.5 SAMPLES |
| 1.6 DELIVERY, STORAGE, AND HANDLING |
| 1.7 QUALITY ASSURANCE |
| 1.7.1 Certifications |
| 1.7.1.1 Certified Sustainably Harvested Wood |
| 1.7.1.2 Indoor Air Quality Certifications |
| 1.7.1.2.1 Adhesives and Sealants |
| 1.7.1.2.2 Composite Wood Products |
| 1.7.2 Lumber |
| 1.7.3 Plywood |
| 1.7.4 Hardboard |
| 1.7.5 Pressure Treated Lumber and Plywood |
| 1.7.6 Non-Pressure Treated Woodwork and Millwork |
| 1.7.7 Fire-Retardant Treated Lumber |
| PART 2 PRODUCTS |
| 2.1 WOOD PRODUCTS |
| 2.1.1 Sizes and Patterns of Wood Products |
| 2.1.2 Species and Grades |
| 2.1.3 Trim, Finish, and Frames |
| 2.1.4 Softwood Plywood |
| 2.1.5 Hardwood Plywood |
| 2.1.6 Hardboard |
| 2.2 FASCIAS AND TRIM |
| 2.2.1 Wood |
| 2.3 COUNTERTOPS |
| 2.3.1 Laminated Plastic-faced Countertops |
| 2.3.1.1 Countertop Finishes |
| 2.3.1.2 Backing Sheet |
| 2.3.2 Solid Surface |
| 2.3.3 Stainless Steel Countertops and Wall Caps |
| 2.4 MOISTURE CONTENT OF WOOD PRODUCTS |
| 2.5 HARDWARE AND ACCESSORIES |
| 2.5.1 Wood Screws |
| 2.5.2 Bolts, Nuts, Lag Screws, and Studs |
| 2.5.3 Nails |
| 2.5.4 Vertical Slotted Shelf Standards |
| 2.6 FABRICATION |
| 2.6.1 Quality Standards QS |
| 2.6.1.1 Grades |
| 2.6.1.2 Adhesives |
| 2.6.2 Countertops |
| 2.6.3 Cabinets |
| 2.6.3.1 Cabinet Hardware |
| 2.6.3.2 Finish |
| 2.6.4 Workbenches |
| 2.6.5 Casework with Transparent Finish CTF |
| 2.6.5.1 AWI Quality Grade |
| 2.6.5.2 Construction |
| 2.6.5.3 Exposed Parts |
| 2.6.5.4 Semi-Exposed Parts |
| 2.6.6 Casework with High Pressure Laminate Finish |
| 2.6.6.1 AWI Quality Grade |
| 2.6.6.2 Construction |
| 2.6.6.3 Exposed Surfaces |
| 2.6.6.4 Semi-Exposed Surfaces |
| PART 3 EXECUTION |
| 3.1 FINISH WORK |
| 3.1.1 Exterior Finish Work |
| 3.1.2 Interior Finish Work |
| 3.1.3 Door Frames |
| 3.1.4 Thresholds |
| 3.1.5 Window Stools and Aprons |
| 3.1.6 Bases |
| 3.2 MISCELLANEOUS |
| 3.2.1 Countertops and Wall Caps |
| 3.2.2 Cabinets |
| 3.2.3 Workbenches |
3.3 MOULDING AND INTERIOR TRIM
| 10 90 00.00 48 |
| 10 90 00.00 48 - MISCELLANEOUS SPECIALTIES PARTIAL OMAR FUNDED |
| PART 1 GENERAL |
| 1.1 SUBMITTALS |
| 1.2 DELIVERY AND STORAGE |
| 1.3 WARRANTY |
| PART 2 PRODUCTS |
| 2.1 MAILBOXES |
| 2.1.1 General |
| 2.1.2 Materials |
| 2.1.3 Color |
| 2.2 SECURITY MESH |
| 2.3 MOORING EYE |
| 2.3.1 Trash and Ash OMAR Funded |
| 2.3.2 Hat and Coat Racks |
| 2.3.3 DELETED |
| 2.3.4 Recycling Bin OMAR Funded |
| 2.3.5 DELETED |
| 2.3.6 Floor Mats |
| 2.3.7 Ballet Rail |
| 2.3.8 DELETED |
| 2.3.9 Refrigerator |
| 2.3.10 Microwave |
| 2.3.11 Compact Refrigerator |
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.2 PROTECTION AND CLEANING |
| 3.3 INSTALLATION OF KITCHEN EQUIPMENT |
File details come from the government source that posted it. Updated .