This document outlines a federal contract opportunity for a Full Facility Restoration project at Fort Hunter Liggett in California. The opportunity involves restoring barracks 207, 208, and 230, with an estimated cost between $10-25 million. The project is set aside entirely for small businesses under NAICS code 236220 for construction of general residential buildings, with a size standard of $39.5 million. Interested parties must register with the System for Award Management at www.sam.gov to comply with various Central Contractor Registration and Online Representations and Certifications Application requirements. Technical inquiries should be submitted through the Bidder Inquiry system at http://projnet.org/projnet. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Louisville.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
G-001
C O
V E
R S
H E
E T
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
BUILDINGS 207, 208 AND 230
FORT HUNTER LIGGETT TRANSIENT TRAINING
BARRACKS FULL FACILITY RENOVATION
07-31-2020
W912QR-17-D-0027
REFER TO THE ATTACHED REFERENCE EXISTING CONDITIONS DRAWINGS FOR PREVIOUS DOCUMENTATION OF
BUILDNG SYSTEMS AND FIRE RATING ASSEMBLIES
CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE
STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.
SCHEDULE - SHEET INDEX
SHEET INFORMATION
NUMBER NAME
M-804 MECHANICAL CONTROLS AND SEQUENCE
M-805 MECHANICAL CONTROLS AND SEQUENCE
M-806 MECHANICAL CONTROLS AND SEQUENCE
M-807 MECHANICAL CONTROLS AND SEQUENCE
M-808 MECHANICAL CONTROLS AND SEQUENCE
ELECTRICAL
E-001 ELECTRICAL - NOTES, SYMBOLS, AND ABBREVIATIONS
ED101 DEMOLITION - ELECTRICAL - BASEMENT FLOOR PLAN
ED110 DEMOLITION - ELECTRICAL - FIRST FLOOR PLAN
ED120 DEMOLITION - ELECTRICAL - SECOND FLOOR PLAN
ED130 DEMOLITION - ELECTRICAL - THIRD FLOOR PLAN
EG110 ELECTRICAL - GROUNDING PLAN
EG111 ELECTRICAL - LIGHTNING PROTECTION PLAN
EG501 ELECTRICAL - GROUNDING DETAILS
EG502 ELECTRICAL - GROUNDING DETAILS
EL101 LIGHTING - BASEMENT FLOOR PLAN
EL110 LIGHTING - FIRST FLOOR PLAN
EL120 LIGHTING - SECOND FLOOR PLAN
EL130 LIGHTING - THIRD FLOOR PLAN
EP101 POWER - BASEMENT FLOOR PLAN
EP110 POWER - FIRST FLOOR PLAN
EP120 POWER - SECOND FLOOR PLAN
EP130 POWER - THIRD FLOOR PLAN
EP140 POWER - ROOF PLAN
E-401 POWER - ENLARGED PLANS
E-501 ELECTRICAL - DETAILS
E-502 ELECTRICAL - DETAILS
E-503 ELECTRICAL - DETAILS
E-601 ELECTRICAL - LIGHTING FIXTURE SCHEDULE
E-602 ELECTRICAL - SINGLE LINE DIAGRAM
E-603 ELECTRICAL - PANEL SCHEDULES
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS - NOTES, SYMBOLS, AND
ABBREVIATIONS
T-110 TELECOMMUNICATIONS - BASEMENT & FIRST FLOOR PLANS
T-120 TELECOMMUNICATIONS - SECOND FLOOR PLAN
T-130 TELECOMMUNICATIONS - THIRD FLOOR PLAN
T-301 TELECOMMUNICATIONS - SECTIONS
T-401 TELECOMMUNICATIONS - ENLARGED PLAN
T-501 TELECOMMUNICATIONS - DETAILS
T-502 TELECOMMUNICATIONS - DETAILS
T-503 TELECOMMUNICATIONS - DETAILS
T-601 TELECOMMUNICATIONS - DIAGRAMS
SCHEDULE - SHEET INDEX
SHEET INFORMATION
NUMBER NAME
P-401 PLUMBING - ENLARGED PLANS
P-402 PLUMBING - ENLARGED PLANS
P-403 PLUMBING - ENLARGED PLANS
P-404 PLUMBING - ENLARGED PLANS
P-405 PLUMBING - ENLARGED PLANS
P-406 PLUMBING - ENLARGED PLANS
P-407 PLUMBING - ENLARGED PLANS
P-408 PLUMBING - ENLARGED PLANS
P-409 PLUMBING - ENLARGED PLANS
P-501 PLUMBING - DETAILS
P-502 PLUMBING - DETAILS
P-601 PLUMBING - SCHEDULES
P-602 PLUMBING - SCHEDULES
P-701 PLUMBING - RISER DIAGRAMS
P-702 PLUMBING - RISER DIAGRAMS
P-703 PLUMBING - RISER DIAGRAMS
P-704 PLUMBING - RISER DIAGRAMS
P-705 PLUMBING - RISER DIAGRAMS
P-706 PLUMBING - RISER DIAGRAMS
P-707 PLUMBING - RISER DIAGRAMS
P-708 PLUMBING - RISER DIAGRAMS
MECHANICAL
M-001 MECHANICAL - SYMBOLS AND ABBREVIATIONS
M-002 MECHANICAL - GENERAL NOTES
MD100 MECHANICAL - BASEMENT FLOOR DEMOLITION PLAN
MD110 MECHANICAL - FIRST FLOOR DEMOLITION PLAN
MD120 MECHANICAL - SECOND FLOOR DEMOLITION PLAN
MD130 MECHANICAL - THIRD FLOOR DEMOLITION PLAN
M-100 MECHANICAL - BASEMENT PLAN
M-110 MECHANICAL - FIRST FLOOR PLAN - COMPREHENSIVE
M-120 MECHANICAL - SECOND FLOOR PLAN - COMPREHENSIVE
M-130 MECHANICAL - THIRD FLOOR PLAN - COMPREHENSIVE
M-150 MECHANICAL - ROOF PLAN
M-401 MECHANICAL - ENLARGED PLANS
M-402 MECHANICAL - ENLARGED PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL - SCHEDULES
M-801 MECHANICAL CONTROLS AND SEQUENCE
M-802 MECHANICAL CONTROLS AND SEQUENCE
M-803 MECHANICAL CONTROLS AND SEQUENCE
SCHEDULE - SHEET INDEX
SHEET INFORMATION
NUMBER NAME
IN202 INTERIOR FINISH - ELEVATIONS
IN203 INTERIOR FINISH - ELEVATIONS
IN401 INTERIOR FINISH - ENLARGED PLANS
IN501 INTERIOR FINISH - DETAILS
IN601 INTERIOR FINISH - ROOM SCHEDULES
IG501 SIGNAGE - DETAILS
IG502 SIGNAGE - DETAILS
IG601 SIGNAGE - SCHEDULES
IG602 SIGNAGE - SCHEDULES
IG603 SIGNAGE - SCHEDULES
IF110 COMPREHENSIVE 1ST FLOOR INTERIOR FURNITURE PLAN
IF111 1ST FLOOR INTERIOR FURNITURE PLAN - AREA A AND D
IF112 1ST FLOOR INTERIOR FURNITURE PLAN - AREA B AND C
IF120 COMPREHENSIVE 2ND FLOOR INTERIOR FURNITURE PLAN
IF121 2ND FLOOR INTERIOR FURNITURE PLAN - AREA A
IF122 2ND FLOOR INTERIOR FURNITURE PLAN - AREA B AND C
IF130 COMPREHENSIVE 3RD FLOOR INTERIOR FURNITURE PLAN
IF131 3RD FLOOR INTERIOR FURNITURE PLAN - AREA A
IF132 3RD FLOOR INTERIOR FURNITURE PLAN - AREA B AND C
PLUMBING
P-001 PLUMBING GENERAL NOTES, ABBREVIATIONS & SYMBOLS
PD101 PLUMBING - BASEMENT DEMOLITION PLAN
PD110 PLUMBING - FIRST FLOOR DEMOLITION PLAN -
COMPREHENSIVE
PD120 PLUMBING - SECOND FLOOR DEMOLITION PLAN -
COMPREHENSIVE
PD130 PLUMBING - THIRD FLOOR DEMOLITION PLAN -
COMPREHENSIVE
PB101 PLUMBING - BASEMENT PLAN
P-110 PLUMBING - FIRST FLOOR PLAN - COMPREHENSIVE
P-111 PLUMBING - FIRST FLOOR PLAN - AREA A
P-112 PLUMBING - FIRST FLOOR PLAN - AREA B
P-113 PLUMBING - FIRST FLOOR PLAN - AREA C
P-120 PLUMBING - SECOND FLOOR PLAN - COMPREHENSIVE
P-121 PLUMBING - SECOND FLOOR PLAN - AREA A
P-122 PLUMBING - SECOND FLOOR PLAN - AREA B
P-123 PLUMBING - SECOND FLOOR PLAN - AREA C
P-130 PLUMBING - THIRD FLOOR PLAN - COMPREHENSIVE
P-131 PLUMBING - THIRD FLOOR PLAN - AREA A
P-132 PLUMBING - THIRD FLOOR PLAN - AREA B
P-133 PLUMBING - THIRD FLOOR PLAN - AREA C
P-140 PLUMBING - ROOF PLAN
SCHEDULE - SHEET INDEX
SHEET INFORMATION
NUMBER NAME
A-140 COMPREHENSIVE ROOF PLAN
AR110 COMPREHENSIVE 1ST FLOOR REFLECTED CEILING PLAN
AR120 COMPREHENSIVE 2ND FLOOR REFLECTED CEILING PLAN
AR130 COMPREHENSIVE 3RD FLOOR REFLECTED CEILING PLAN
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-401 ENLARGED RESTROOM PLAN
A-402 STAIR DETAILS
A-403 STAIR DETAILS
A-501 DETAIL SECTION VIEWS
A-502 DETAIL SECTION VIEWS
A-601 PARTITION TYPES (METAL STUDS)
A-611 DOOR SCHEDULE
A-612 DOOR SCHEDULE, DOOR AND WINDOW ELEVATIONS
A-613 DOOR AND WINDOW - HEAD AND JAMB DETAILS
INTERIORS
IN001 INTERIOR FINISH AND SIGNAGE - DETAILED NOTES, LEGENDS
AND MATERIAL & COLOR SCHEDULE
IN110 COMPREHENSIVE 1ST FLOOR INTERIOR FINISH AND SIGNAGE
PLAN
IN111 1ST FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA A
AND D
IN112 1ST FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA B
AND C
IN120 COMPREHENSIVE 2ND FLOOR INTERIOR FINISH AND SIGNAGE
PLAN
IN121 2ND FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA A
IN122 2ND FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA B
AND C
IN130 COMPREHENSIVE 3RD FLOOR INTERIOR FINISH AND SIGNAGE
PLAN
IN131 3RD FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA A
IN132 3RD FLOOR INTERIOR FINISH AND SIGNAGE PLAN - AREA B
AND C
IN201 INTERIOR FINISH - ELEVATIONS
SCHEDULE - SHEET INDEX
SHEET INFORMATION
NUMBER NAME
GENERAL
G-001 COVER SHEET
G-002 SITE VICINITY MAPS
HAZMAT
H-110 FIRST FLOOR COMPREHENSIVE HAZMAT
H-120 SECOND FLOOR COMPREHENSIVE HAZMAT
H-130 THIRD FLOOR COMPREHENSIVE HAZMAT
H-140 ROOF PLAN COMPREHENSIVE HAZMAT
CIVIL
C-100 TELECOMMUNICATIONS SITE PLAN
ARCHITECTURE
A-001 ARCHITECTURAL GENERAL NOTES, MATERIAL & ANNOTATION
LEGEND
A-002 TYPICAL ADA DETAILS
AD110 COMPREHENSIVE FIRST FLOOR DEMOLITION PLAN
AD111 COMPREHENSIVE FIRST FLOOR DEMOLITION REFLECTED
CEILING PLAN
AD120 COMPREHENSIVE SECOND FLOOR DEMOLITION PLAN
AD121 COMPREHENSIVE SECOND FLOOR DEMOLITION REFLECTED
CEILING PLAN
AD130 COMPREHENSIVE THIRD FLOOR DEMOLITION PLAN
AD131 COMPREHENSIVE THIRD FLOOR DEMOLITION REFLECTED
CEILING PLAN
A-101 BASEMENT FLOOR PLAN
A-110 COMPREHENSIVE FIRST FLOOR PLAN
A-111 1ST FLOOR PLAN - AREA A & D
A-112 1ST FLOOR PLAN - AREA B & C
A-120 COMPREHENSIVE SECOND FLOOR PLAN
A-121 2ND FLOOR PLAN - AREA A
A-122 2ND FLOOR PLAN - AREA B & C
A-130 COMPREHENSIVE THIRD FLOOR PLAN
A-131 3RD FLOOR PLAN AREA A
A-132 3RD FLOOR PLAN AREA B & C
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
© 2020 Microsoft Corporation © 2019 DigitalGlobe ©CNES (2019) Distribution Airbus DS
PNN
C E
R T
I F
I E
D
F
I N
A L
S
U B
M I S
S I O
N
J U
L Y
US Army Corps of Engineers ®
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
C T
N
S O
L I C
I T
A T
I O
N
N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R I P
T I O
N D
A T
E
W Q
R F
W Q
R D
F O
H
N
T E
R
L I G
G E
T T
T R
A I N
I N
G
B
A R
R A
C K
S
F
U L L
F
A C
I L I T
Y
R
E N
O V
A T
I O
N
B U
I L D
I N
G
A
D
P N
L O
U I S
V I L
E
I S
T R
I C
T
L O
U I S
V I L L E
K
Y
LOUISVILLE DISTRICT
M
I
S
S
I
A
D
SCALE:
LOCATION MAP
N.T.S.
G-002
FORT
HUNTER
LIGGETT
SCALE:
LOCATION MAP
N.T.S.
G-002
SCALE:
SITE VICINITY MAP
1" = 300'
G-002
FORT
HUNTER
LIGGETT
PN&N
PN&N
MAIN GATE
VISITOR
CENTER
B
R
A
D
L
I V
E
B R
A D
L E
Y
D
R I V
E
V
I S
I
A
D
I N
F A
N
T
A
D
R
M
P
A
CONTRACTOR
ACCESS
ROUTE
CONTRACTOR
ACCESS
ROUTE
CONTRACTOR
ACCESS
ROUTE
CONTRACTOR
LAYDOWN/
STAGING AREA
G-002
S I T
E
V
I C
I N
I T
Y
M
A P
S
A
V
A S
K O
V
A
V
A S
K O
V
S
S
A V
I C
H
COYOTE DR.
BUILDING 230
BUILDING 208
BUILDING 207
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
C E
R T
I F
I E
D
F
I N
A L
S
U B
M I S
S I O
N
J U
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
C
S O
L I C
I T
A T
I O
N
N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R I P
T I O
N D
A T
E
W Q
R F
W Q
R D
F O
N
T E
R
L I G
G E
T T
T R
A I N
I N
G
B
A R
R A
C K
S
F
U L L
F
A C
I L I T
Y
R
E N
O V
A T
I O
N
B U
I L D
I N
G
A
P N
L O
U I S
V I L
S
T R
I C
T
L O
U I S
V I L L E
K
Y
LOUISVILLE DISTRICT
PNN
SCALE: 1''=150'-0''
150 75 0 150
NOTES:
1. THE CONTRACTOR SHALL, AT HIS OWN
EXPENSE, OBTAIN ANY FIELD SURVEY
INFORMATION REQUIRED TO PROVIDE
A COMPLETE AND USABLE DESIGN.
2. ALL CABLING TO BE INSTALLED IN
EXISTING UNDERGROUND
INFRASTRUCTURE. PROVIDE AND
INSTALL SINGLE MODE FIBER OPTIC
CABLING WITH FIBER COUNT NOTED ON
DRAWING.
3. EACH 36-STRAND SINGLE MODE SPLICE
TO 144 STRAND SINGLE MODE AT
MANHOLE SOUTH OF BLDG 206 TO BE
PERFORMED BY CONTRACTOR.
4. CONTRACTOR TO TERMINATE FIBER IN
BUILDINGS 241, 3010, AND 3011 WITH
L.C. CONNECTORS. FHLNEC
PERSONNEL TO MAKE FINAL
CONNECTIONS.
5. DURING CONSTRUCTION THE
CONTRACTOR SHALL PROVIDE ALL
NECESSARY BARRIERS AND SIGNAGE
FOR THE PROTECTION OF PEDESTRIAN
AND VEHICULAR TRAFFIC.
6. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR PROVIDING ALL
NECESSARY EROSION AND
SEDIMENTATION CONTROL MEASURES
FOR THE PROTECTION OF EXISTING
STORM SEWER STRUCTURES, AND
WATERWAYS. ALL EROSION AND
SEDIMENTATION CONTROL MEASURES
SHALL BE IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL
REGULATIONS.
THE CONSTRUCTION AND PLACEMENT
OF EROSION AND SEDIMENTATION
DEVICES SHALL BE APPROVED BY THE
CONTRACTING OFFICER.
NPDES PERMIT WILL NOT BE
REQUIRED FOR THIS PROJECT.
C-100
T E
L E
C O
M M
U N
I C
A T
I O
T
E
P
L A
N
A
V
A S
K O
V
A
V
A S
K O
V
J
G
O L D
C A
M P
PATCH 8-STRAND SM
BETWEEN 3010 & 3011
ASSUME 350'
VERIFY IN FIELD
36 STRAND SM
ASSUME 400'
VERIFY IN FIELD
36 STRAND SM
ASSUME 250'
VERIFY IN FIELD
36 STRAND SM
ASSUME 250'
VERIFY IN FIELD
144 STRAND SM
ASSUME 2,200'
VERIFY IN FIELD
8 STRAND SM
ASSUME 3,950'
VERIFY IN FIELD
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
WDWDWDWDWDWDWD
UP
UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
DAY
ROOM
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
LIVING/SLEEPING
BAY
LINEN
L
A V
A T
O R
IE
S
LIVING/SLEEPING
BAY
LINEN
SHOWERS
VESTIBULE
CORRIDOR
FIRST SERGEANTS &
CLERKS OFFICE
C O
M M
A N
D
IN
G
O F
F
IC
E R
E X
E C
U T
IV
E
O F
F
IC
E R
CONFERENCE
STORAGE
UNISEX
ELEC
CLOSET
EF
TRAINING
EQUIPMENT
MAINTENANCE
JAN
UNISEX
NUCLEAR
BIO &
CHEMICAL
COMO
UNIT
STORAGE
ARMS
VAULT
CORRIDOR
JAN
ELEC
CLOSET
TELECOMM
CLOSET
CORRIDOR110
ELEC
STAIR 1
TER
CLOSET
120A
CLOSET
S
H O
W E
R S
TOILET
SHOWERS
TOILET
TOILET
LAVATORIES
111A
STAIR 3
117A
STAIR 2
102A
STAIR 4
BBBB
BB
A
A
A A
A
A
A
A A
AA
A
A
A
A
A
A
A
A
A
A
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
H-110
F
IR
S T
F L O
O R
C O
M P
R E
H E
N S
IV
E
H A
Z M
A T
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE: 3/32" = 1'-0"
COMPREHENSIVE FIRST FLOOR ASBESTOS REMOVAL PLAN
NOTES: ABATEMENT PLAN
1. THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. THE CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2. ALL WORK IS TO BE DONE IN COMPLIANCE WITH
ALL APPLICABLE CODES, LAWS AND REGULATIONS.
3. PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE, OR DISRUPTION OF OPERATION.
4. SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE CONTRACTOR
SHALL COORDINATE WITH THE CONTRACTING
OFFICER.
5. REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
6. ALL DOORS ARE ASSUMED TO BE FIRE-RATED
AND MAY CONTAIN ASBESTOS. REMOVE AND
HANDLE WITH PROPER CARE.
KEYNOTES:
A – REMOVE VINYL FLOOR TILE AND FLOOR
ADHESIVE
B – REMOVE CEMENT WINDOW PANEL
C – REMOVE ASPHALTIC ROOF FLASHING MATERIAL
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
LIVING/SLEEPING
BAY
LINEN
TOILET
SHOWERS
LINEN
LIVING/SLEEPING
BAY
DAY
ROOM
CORRIDOR
SHOWERS
LINEN
LIVING/SLEEPING
BAY
ELEC
CLOSET
TELECOMM
CLOSET
TR
JAN210
ELEC
STAIR 1207
CLOSET
CLOSET
L
A V
A T
O R
IE
S
S
H O
W E
R S
TOILET
LAVATORIES
LAVATORIES
TOILET
NOTE - REFER TO
GENERAL NOTE 31 ON
SHEET A-001 FOR
DEMOLITION OF
EXISTING ROOF
ASSEMBLY
202A
STAIR 4
211A
STAIR 3
217A
STAIR 2
A
A
A
A
A A
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
H-120
S E
C O
N D
F L O
O R
C O
M P
R E
H E
N S
IV
E
H A
Z M
A T
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE: 3/32" = 1'-0"
COMPREHENSIVE SECOND FLOOR ASBESTOS REMOVAL PLAN
NOTES: ABATEMENT PLAN
1. THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. THE CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2. ALL WORK IS TO BE DONE IN COMPLIANCE WITH
ALL APPLICABLE CODES, LAWS AND REGULATIONS.
3. PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE, OR DISRUPTION OF OPERATION.
4. SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE CONTRACTOR
SHALL COORDINATE WITH THE CONTRACTING
OFFICER.
5. REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
6. ALL DOORS ARE ASSUMED TO BE FIRE-RATED
AND MAY CONTAIN ASBESTOS. REMOVE AND
HANDLE WITH PROPER CARE.
KEYNOTES:
A – REMOVE VINYL FLOOR TILE AND FLOOR
ADHESIVE
B – REMOVE CEMENT WINDOW PANEL
C – REMOVE ASPHALTIC ROOF FLASHING MATERIAL
A
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
J
K
L
M
CORRIDOR
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
LIVING/SLEEPING
BAY
LINEN
TOILET
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
DAY
ROOM
ELEC
CLOSET
TELECOM
CLOSET
ELEC
JAN 308
TR
STAIR 1
CLOSET
CLOSET
L
A V
A T
O R
IE
S
S
H O
W E
R S
SHOWERS
SHOWERS
TOILET
TOILET
A
A
A
A
A A
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
H-130
T H
IR
D
F L O
O R
C O
M P
R E
H E
N S
IV
E
H A
Z M
A T
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE: 3/32" = 1'-0"
COMPREHENSIVE THIRD FLOOR ASBESTOS REMOVAL PLAN
NOTES: ABATEMENT PLAN
1. THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. THE CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2. ALL WORK IS TO BE DONE IN COMPLIANCE WITH
ALL APPLICABLE CODES, LAWS AND REGULATIONS.
3. PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE, OR DISRUPTION OF OPERATION.
4. SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE CONTRACTOR
SHALL COORDINATE WITH THE CONTRACTING
OFFICER.
5. REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
6. ALL DOORS ARE ASSUMED TO BE FIRE-RATED
AND MAY CONTAIN ASBESTOS. REMOVE AND
HANDLE WITH PROPER CARE.
KEYNOTES:
A – REMOVE VINYL FLOOR TILE AND FLOOR
ADHESIVE
B – REMOVE CEMENT WINDOW PANEL
C – REMOVE ASPHALTIC ROOF FLASHING MATERIAL
A
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
/8
/8
3/8" / 12" 3/8" / 12"
/8
/8
3/8" / 12" 3/8" / 12"
/8
/8
3/8" / 12"
C
C
C C
C
C
C
C
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
H-140
R O
O F
P L A
N C
O M
P R
E H
E N
S
IV
E H
A Z
M A
T
D e s ig n e r
A u th o r
C h e c k e r
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE: 3/32" = 1'-0"
COMPREHENSIVE ROOF ASBESTOS REMOVAL PLAN
NOTES: ABATEMENT PLAN
1. THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. THE CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2. ALL WORK IS TO BE DONE IN COMPLIANCE WITH
ALL APPLICABLE CODES, LAWS AND REGULATIONS.
3. PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE, OR DISRUPTION OF OPERATION.
4. SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE CONTRACTOR
SHALL COORDINATE WITH THE CONTRACTING
OFFICER.
5. REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
6. ALL DOORS ARE ASSUMED TO BE FIRE-RATED
AND MAY CONTAIN ASBESTOS. REMOVE AND
HANDLE WITH PROPER CARE.
KEYNOTES:
A – REMOVE VINYL FLOOR TILE AND FLOOR
ADHESIVE
B – REMOVE CEMENT WINDOW PANEL
C – REMOVE ASPHALTIC ROOF FLASHING MATERIAL
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
CONCRETE BLOCK
SECTIONS/ SECTIONAL DETAILS
CAST-IN-PLACE-CONCRETE
STRUCTURAL/MISCELLANEO
US STEEL
EARTH
GRAVEL/ENGINEERED
FILL
STONE, OR NATURAL
BUILDING STONE
PLASTER OR GYPSUM
BOARD, OR EXTERIOR
SHEATHING
BATT INSULATION
ROOF, TAPERED, CAVITY OR
RIGID INSULATION
FINISHED WOOD TRIM
PLYWOOD
CAVITY DRAINAGE MATERIAL
SYMBOLS
CALLOUT PLAN,
SECTION OR DETAIL
BUILDING SECTION
WALL SECTION
INTERIOR SECTION
DETAIL SECTION
INTERIOR EXTERIOR
ELEVATIONS
VIEW TITLE
SCALE:
VIEW CALLOUT
COLUMN GRID LABEL -
NEW
COLUMN GRID LABEL -
EXISTING
REVISION
ROOM TAG
DOOR TAG - SEE
SCHEDULE
PARTITION TYPE#X#.#
ROOM NAME
##.## KEYNOTE
TOILET ROOM
ACCESSORIES
ELEVATION MARK
DENOTES ABOVE, BELOW,
OR BEHIND
WINDOW TYPE
ACCESSIBLE TOILET STALL
RECYCLING
COLLECTION AREA
LEVEL LINE
SLOPE
CENTER LINE
FLOOR TRANSITION
ROOF SLOPE ARROW
SPOT ELEVATION
NORTH ARROW
PLAN
NORTH
N
PLANS / PLAN DETAIL GRAPHICS
CONCRETE BLOCK WALLS
CAST-IN-PLACE-
CONCRETE WALLS
STUD WALLS
BRICK WALLS
CONCRETE SLABS AND/OR
CONCRETE SIDEWALKS
EXITSTING WALLS
SMOKE
1 HOUR
2 HOUR
3 HOUR
4 HOUR
PLANS/ PLAN FIRE RATED GRAPHICS
1/2 HOUR
DOOR DESIGNATIONS
EXISTING DOOR AND/OR FRAME TO
REMAIN - SEE DOOR SCHEDULE FOR ANY
ADDITIONAL WORK
EXISTING DOOR AND/OR FRAME TO BE
REMOVED - SEE DEMO PLAN/NOTES
NEW DOOR AND/OR FRAME TO BE
PROVIDED - SEE DOOR SCHEDULE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
A-001
A R
C H
IT
E
C T
U R
A L G
E N
E R
A L N
O T
E S
M
A T
E R
IA
L
A N
N O
T A
T
IO
N L
E G
E N
D
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
NOTES - GENERAL
1 ALL DIMENSIONS ARE IN FEET / INCHES UNLESS NOTED OTHERWISE
2 THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE SPECIFICATIONS - REFER TO
SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TO GENERAL NOTES
3 THE TERMS RENOVATE AND REHABILITATE ARE USED INTERCHANGEABLY IN THESE
DOCUMENTS.
4 ROOM AREAS AND PERIMETERS ARE APPROXIMATE AND FOR REFERENCE ONLY.
VERIFY QUANTITIES AND DIMENSIONS IN FIELD.
5 NO DEVIATIONS FROM THESE CONTRACT DOCUMENTS SHALL BE MADE WITHOUT THE
PRIOR WRITTEN APPROVAL OF THE ARCHITECT
6 DO NOT SCALE DIMENSIONS FROM DRAWINGS - THE CONTRACTOR SHALL REQUEST
NECESSARY DIMENSIONS NOT SHOWN ON THE DRAWINGS FROM THE ARCHITECT
7 ALL DIMENSIONS ARE TO FACE OF PARTITION OR CENTER OF DOORS, WINDOWS AND
OPENINGS UNLESS NOTED OTHERWISE - ALL NON-DIMENSIONED DOOR LOCATIONS
SHALL BE OFFSET 4" FROM THE ADJACENT WALL TO THE HINGE SIDE OF THE DOOR
OPENING.
8 DETAILS SHOWN ON DRAWINGS ARE TYPICAL FOR ALL SIMILAR CONDITIONS.
9 DRAWING NOTES AND SPECIFICATIONS ARE INSTRUCTIONS TO THE CONTRACTOR AND
APPLY TO ALL THE WORK UNLESS MORE SPECIFIC INFORMATION IS SHOWN
ELSEWHERE ON THE DRAWINGS OR WRITTEN IN THE SPECIFICATIONS - IN THE EVENT
OF CONFLICTING INSTRUCTIONS, THE ARCHITECT SHALL DETERMINE WHAT CONTROLS
10 VERIFY ALL DIMENSIONS IN THE FIELD AND COORDINATE DIMENSIONS SHOWN ON THE
CONTRACT DRAWINGS WITH FABRICATION AND FIELD CONDITIONS AND REPORT ANY
INCONSISTENCIES TO THE ARCHITECT BEFORE PROCEEDING WITH WORK
11 PRINCIPAL OPENINGS IN THE STRUCTURE ARE SHOWN ON THESE DRAWINGS - THE
GENERAL CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, MECHANICAL,
ELECTRICAL, AND PLUMBING DRAWINGS FOR REQUIRED OPENINGS GENERAL
CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL OPENINGS WITH ALL
SUB-CONTRACTORS PRIOR TO CONSTRUCTION
12 STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED
STRUCTURE, AND, EXCEPT WHERE SPECIFICALLY SHOWN, DO NOT INDICATE THE
METHOD OR MEANS OF CONSTRUCTION - THE CONTRACTOR SHALL SUPERVISE
CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, SEQUENCE, AND
APPLICABLE SAFETY REGULATIONS TO BE FOLLOWED
13 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING THE
WORK OF THE SUB-CONTRACTORS - THE CONTRACTOR SHALL BE RESPONSIBLE TO
COORDINATE WITH THE BUILDING OWNER, TENANT OR HIS REPRESENTATIVES THE
DELIVERY AND INSTALLATION OF ITEMS BEING PROVIDED AND INSTALLED BY OTHERS
14 MECHANICAL, PLUMBING AND ELECTRICAL WORK RELATED TO DEMOLITION AND NEW
INSTALLATION OF COMPONENTS SHALL COMPLY WITH ALL APPLICABLE CODES
15 ALL MATERIALS, FABRICATION AND INSTALLATION SHALL COMPLY WITH THE
APPLICABLE REQUIREMENTS AND SPECIFICATIONS FOR EACH DIVISION OF WORK
16 CONSTRUCTION MUST COMPLY WITH APPLICABLE CODES AND ORDINANCES, LAWS
AND SAFETY ORDERS AS DIRECTED BY LOCAL JURISDICTION
17 CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS
INCLUDED IN THESE CONTRACT DOCUMENTS - SOME ITEMS IN THESE DOCUMENTS
MAY REQUIRE LONG LEAD TIMES OR SPECIAL COORDINATION SUBSTITUTIONS WILL
NOT BE ALLOWED FOR MATERIAL NOT ORDERED IN A TIMELY FASHION
18 CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND GRADE CONDITIONS,
(BOTH NEW AND EXISTING) REPORTING ANY DISCREPANCIES TO THE ARCHITECT
PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH ANY PHASE OF THE WORK
19 CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS PRIOR TO COMMENCING
CONSTRUCTION - ALL DISCREPANCIES SHALL BE NOTED AND SENT TO THE ARCHITECT
WITH ADEQUATE TIME TO REVIEW PRIOR TO STARTING THAT PORTION OF THE WORK
IN ORDER TO AVOID PROJECT DELAYS
20 CONTRACTOR SHALL CLEAN, PATCH AND REPAIR ALL SURFACES DAMAGED BY
DEMOLITION, ALTERATION OR INSTALLATION OF THE WORK
21 CONTRACTOR SHALL PREPARE ALL WALLS AND PARTITIONS AS REQUIRED BY THE
FINISH MANUFACTURER TO RECEIVE THE FINISHES SPECIFIED
22 CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY
CORNERS DURING CONSTRUCTION
23 CONTRACTOR SHALL PROVIDE ADDITIONAL FURRING (THE ENTIRE LENGTH OF THE
WALL) TO FULLY CONCEAL ALL MECHANICAL, ELECTRICAL, PLUMBING AND
STRUCTURAL ITEMS THAT PROJECT FROM THE FACE OF THE WALL OR PARTITION AND
ARE NOT SPECIFICALLY NOTED TO BE SURFACE MOUNTED
24 CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS,
BUILDING UTILITY ENTRANCE LOCATIONS AND EXACT LOCATIONS AND DIMENSIONS OF
EXITS, CANOPIES, RAMPS, DOWNSPOUTS, GRAVEL AREAS ADJACENT TO BUILDING
WALLS, UTILITY ENTRANCE LOCATIONS AND BOLLARDS IN BUILDING WALKWAYS
25 CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS PRIOR TO
COMMENCING CONSTRUCTION - ALL DISCREPANCIES SHALL BE NOTED AND SENT TO
THE ARCHITECT WITH ADEQUATE TIME TO REVIEW PRIOR TO STARTING THAT PORTION
OF THE WORK IN ORDER TO AVOID PROJECT DELAYS
26 CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH
LOCAL JURISDICTION AND NFPA 10. MAXIMUM TRAVEL DISTANCE TO NEAREST FIRE
EXTINGUISHER FROM ANY POINT IN THE BUILDING SHALL NOT EXCEED 50 FEET.
EXISTING FIRE EXTINGUISHERS SHALL BE TESTED AND RE-USED IF FULLY
OPERATIONAL. FIRE EXTINGUISHERS SHALL BE SIZED FOR NO LESS THAN ORDINARY
HAZARD.
27 REMOVE AND REINSTALL PICTURES, TV'S, BULLETIN BOARDS ETC, PRIOR TO AND
AFTER PAINTING
28 ALL REQUESTS FROM INFORMATION PROMPTED BY THE BUILDING OFFICIALS SHALL
INCLUDE A COPY OF THE BUILDING OFFICIALS COMMENTS AND THE BUILDING
INSPECTORS FIELD REPORT TO ENSURE AN ACCURATE AND TIMELY RESPONSE
29 CONTRACTOR AND SUBCONTRACTOR SHALL ALL BE LICENSED TO PERFORM THEIR
REQUESTED DUTIES AS REQUIRED IN ACCORDANCE WITH LOCAL STANDARDS
30 CONTRACTOR SHALL COMPARE STRUCTURAL SECTIONS WITH ARCHITECTURAL
SECTIONS AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO
FABRICATION OR INSTALLATION OF STRUCTURAL MEMBERS
31 REMOVE EXISTING ROOF ASSEMBLY, INSULATION COPING, GUTTERS, AND
DOWNSPOUTS. ROOF ASSEMBLY TO BE REMOVED DOWN TO THE ROOF DECK. SEE
H-SERIES - PREPARE DECK FOR NEW ROOF ASSEMBLY, COPINGS, DOWNSPOUTS AND
GUTTERS AS INDICATED
ABB DESCRIPTION
REG REGISTER
REINF REINFORCING
REQ'D REQUIRED
RFG REFRIGERATOR
RG RANGE
RM ROOM
RO ROUGH OPENING
RTS RUBBER TRANSITION STRIP
RWC RAIN WATER CONDUCTOR
__________ S __________
S SOUTH
SAN SANITARY
SCHD SCHEDULE
SEC SECTION
SF SQUARE FOOT
SIM SIMILAR
SPKLR SPRINKLER
SQ SQUARE
SQ FT SQUARE FOOT
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
SUSP SUSPEND, SUSPENDED, OR SUSPENSION
SYS SYSTEM
__________ T __________
"T" TEE (BAR OR W)
T TREAD
T/ TOP OF
T/C TOP OF CURB
TB TACKBOARD
TC TERRA COTTA
TEL TELEPHONE
TEMP TEMPERED OR TEMPERATURE
TERM TERMINATE / TERMINAL
THRESH THRESHOLD
TLT TOILET
TV TELEVISION
TYP TYPICAL
__________ U __________
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
UMCT UNGLAZED MOSAIC CERAMIC TILE
UNO UNLESS NOTED OTHERWISE
__________ V __________
VEST VESTIBULE
VIF VERIFY IN FIELD
__________ W __________
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WIN WINDOW
WP WATERPROOF(ING)
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE REINFORCEMENT
ABB DESCRIPTION
FT FOOT/FEET
__________ G __________
GA GAUGE
GL GLASS OR GLAZING
GRD GROUND
GWB GYPSUM WALL BOARD
__________ H __________
HB HOSE BIBB
HC HANDICAP(PED)
HDW HARDWARE
HM HOLLOW METAL
HOR HORIZONTAL
HP HIGH POINT
HTR HEATER
__________ I __________
ID INSIDE DIAMETER
IN INCH(ES)
INT INTERIOR
__________ J __________
JB JAMB
JST JOIST
JT JOINT
__________ L __________
LAM LAMINATE
LAN LOCAL AREA NETWORK CONNECTION
LAV LAVATORY
LB POUND
LF LINEAL FOOT
LP LOW POINT
LTL LINTEL
__________ M __________ m METERS
MAS MASONRY
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURE
MH MANHOLE
MICRO MICROWAVE
MIN MINIMUM
MISC MISCELLANEOUS
mm MILLIMETERS
MO MASONRY OPENING
MTD MOUNTED EL
MTL METAL
__________ N __________
N NORTH
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
__________ O __________
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
__________ P __________
PART PARTITION
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PNL PANEL
POS POINT OF SALE
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PROP PROPERTY
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PT POINT
PTD PAINTED
__________ Q __________
QTY QUANTITY
__________ R __________
R RISER OR RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFER / REFERENCE
ABB DESCRIPTION
__________ A __________
& AND
< ANGLE
@ AT
A/ ABOVE
ACP ACOUSTIC CEILING PANEL
ADJ ADJACENT, ADJUSTABLE
AED AUTOMATED EXTERNAL DEFIBRILLATOR
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
APPROX APPROXIMATE(LY)
ARCH ARCHITECT OR ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING
MATERIAL
ATTEN ATTENUATE, ATTENUATION
AVG AVERAGE
__________ B __________
B/ BOTTOM OF
B/C BOTTOM OF CURB
BC BASE CABINET
BD BOARD
BIT BITUMINOUS
BLDG BUILDING
BSMT BASEMENT
__________ C __________
[ CHANNEL
C/ CENTER OF
CAB CABINET
CC CENTER TO CENTER
CG CORNER GUARD
CJ CORNER JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CP COPIER
CT CERAMIC TILE
CY CUBIC YARD
__________ D __________
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DW DISHWASHER
DWG DRAWING
__________ E __________
E EAST
EA EACH
EB EDGE BANDING
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSE(URE)
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP BLT EXPANSION BOLT
EXT EXTERIOR
__________ F __________
< FABRIC
F/F FACE TO FACE
FAX FACSIMILE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FL FLOOR
FL CO FLOOR CLEANOUT
FP FIRE PROTECTION
FPRF FIREPROOF(ING)
FR FIRE RATED OR FRAME
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
REAR WALL ELEV
42" SIDE WALL
GRAB BAR
TOILET PAPER DISPENSER
PARTITION
18" VERTICAL GRAB BAR
1' - 6"
M A
X
M
IN
1/
2" M
IN
9" MAX
7" MIN
WATER CLOSET IS FOR REF.
SEE P-SERIES FOR TYPE
36" REAR WALL
GRAB BAR
SEAT COVER
DISPENSER
1 1/2 " GAP
FLUSH CONTROL
ON OPEN SIDE OF WC 44
M
A X
39" MIN - 41" MAX
MAX
12".
48" MAX
24" MIN
NAPKIN
DISPOSAL
T /O
G R
IP
P
IN
G
S U
R F
A C
E
M
IN
M
A X
T /O
S U
R F
A C
E
M
IN
M
A X
SIDE WALL ELEV
2' - 0" 1' - 0"
36" AMBULATORY
5' - 0" MIN CLEAR WHEEL CHAIR
59" MIN CLEAR WHEEL CHAIR ACCESSIBLE FLOOR MOUNTED
56" MIN CLEAR NON-ACCESSIBLE
56" MIN CLEAR WHEEL CHAIR ACCESSIBLE WALL HUNG
M A
X
M
IN
42" SIDE WALL GRAB
BAR @ AMBULATORY
60" MIN CLEAR AMBULATORY
M
IN9"
T O
O P
E R
A B
LE
P
A R
T S
M A
X
M A
X
M
IN
TOILET ROOMS WITH STALLSTOILET STALLS
CL OPENING
DRINKING FOUNTAINS SIGNS & COUNTERS
APRON
FRONT VIEW (DOUBLE)
ADA
COMPLIANT
EWC
STANDARD
EWC
FACE OF
ADJACENT
WALL
SIDE VIEW
EDGE OF WALL
BEYOND
WIDTH OF ALCOVE
48" MIN
T O
S P
O U
T
M A
X
TO SPOUT
24" MIN CLR
O F
L E
A D
IN
G
E D
G E
T O
B O
T T
O M
CLR FLOOR SPACE
30" MIN
DEPTH OF
24" MAX
ALCOVE
T O
S P
O U
T
M A
X
9" M
IN
6" MAX 8" MIN
T O
B O
T T
O M
M
IN
F O
R C
LR
15" MIN. 5" MAX.
CL
INSULATE OR CONCEAL ALL
WATER & DRAIN PIPES
SOAP DISPENSER
MIRROR FEMININE NAPKIN
DISPENSER
PAPER TOWEL
DISPENSER
M A
X
A D
A /T
A S
M A
X
S T
A N
D A
R D
M A
X
9" M
IN27
M
IN
M
IN
M A
X
FAUCET AND SOAP DISPENSER CONTROLS
SHALL HAVE A REACH DEPTH OF 11" MAX
OBSTRUCTED REACH TO OPERABLE PARTS ON
DISPENSERS AND HAND DRYERS SHALL COMPLY
WITH ANSI
M A
X U
N O
B S
T R
T /O
O P
E R
A B
LE
P
A R
T S
M A
X
T /O
O P
E R
A B
LE
P
A R
T S
M A
X
T /O
O P
E R
A B
LE
P
A R
T S
M A
X
SINKS
(N
O T
IN
K
S
M
IN
T O
T
G
LA
S S
PAPER TOWEL
DISPENSER &
WASTE
RECEPTACLE
CLEAR
FLOOR
SPACE
36" IF IN ALCOVE
GREATER THAN 24" DEEP
30" TYP
T Y
P
TAPERED
ELONGATED
RIM
14" TYP
CLEAR FLOOR
SPACE
M
IN
M A
X
M
IN
30" MIN
32"" MIN
36" MIN 16
42" ICC/ANSI A117.1
GOVERNS - CLEAR FROM
OUTSIDE FACE OF
ADJACENT STALL
42" MIN
56" MIN WALL MOUNTED WC
59" MIN FLOOR MOUNTED WC
M
IN
6" M
A X
12" MAX
M
IN
CL
4' - 6" MIN
1. TOE CLEARANCE AT THE FRONT OF THE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 62" DEEP WITH A WALL-HUNG WATER CLOSET OR 65" DEEP WITH A FLOOR-MOUNTED WATER CLOSET. TOE CLEARANCE AT THE SIDE IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" WIDE (ICC/ANSI A117.1). TOE CLEARANCE IS EXCLUSIVE OF PARTITION SUPPORT MEMBERS. IF DEPTH OF STALL IS GREATER THAN 60", TOE CLEARANCE DOES NOT APPLY - ADA. (ICC/ANSI A117.1
GOVERNS).
2. WHERE 6 OR MORE STALLS ARE PROVIDED, IN ADDITION TO STANDARD STALL, PROVIDE AT LEAST 1 AMBULATORY STALL 36" WIDE WITH A DOOR THAT SWINGS OUT AND THE DEPTH OF THE STALL AS REQUIRED TO ACCOMMODATE LENGTH OF GRAB BAR.
STALL SHALL BE IN ACCORDANCE TO APPLICABLE PLUMBING CODE.
ALTERNATE WHEELCHAIR ACCESSIBLE STALL
EXIT
BACKSPLASH
CEILING, PENDANT OR WALL
MOUNTED EXIT SIGN
COUNTER
M A
X 4"
4"
CL
URINAL
T O
O P
E R
A T
IN
G
P A
R T
S
LE
A
D
IN
G E
D G
E W
H
O
JE
C T
IO
N
I S
M O
A
N
SIDE VIEW FRONT VIEW
FACE OF WALL
HANDLE
4" MAX INCLUDING
CLR FLOOR SPACE
30" MIN
CLR FLOOR SPACE
48" MIN
T O
B O
T T
O M
M
IN
R E
A C
H H
E
IG
H T
M A
X
FIRE EXTINGUISHER
TOILET FIXTURES & ACCESSORIES
T /O
O P
E R
A B
LE
P
A R
T S
M A
X
LIGHT SWITCH
T /O
O P
E R
A B
LE
P
A R
T S
M A
X
KNEE CLEARANCE
8" MIN
11" MIN 6" MAX
M A
X
M A
X
M
IN
M
IN9"
24" MIN
M
IN
. I F
C
LO
S E
R P
R O
V
ID
E D
M
IN
4" TYP
22" MIN
M
IN
IF
C
LO
S
E R
A N
D L
A T
C H
P R
O V
ID
E
D
M
IN
M
IN
H
IN
G
E A
P P
R O
A C
H
M
IN
H
IN
G
E A
P P
R O
A C
H
42" MIN
36" MIN
NOTE: X =
12 IF DOOR
HAS BOTH
A CLOSER
AND A
LATCH
X" MIN4" TYP
18" MIN
M
IN
M
IN
DOOR CLEARANCES
CL
42" MAX.
M
IN
M
A X
SHOWER STALL CLEARANCES
SHOWER CURTAIN ROD
(BEHIND)
REAR WALL ELEV
(CENTER)
SHOWER CURTAIN ROD
SHOWER HEAD
LINE OF REAR
WALL
SHOWERHEAD /
HAND SHOWER
3' - 0"
6'
CONTROL WALL ELEV
(RIGHT SIDE)
6'
1' - 6"
THRESHOLD 1/2" MAX. HT.
BEVELED AT 45
M A
X
M
IN
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
A-002
T Y
P
IC
A L A
D A
D E
T A
IL
S
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
UP
DAY
ROOM
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
LIVING/SLEEPING
BAY
LINEN
L
A V
A T
O R
IE
S
LIVING/SLEEPING
BAY
LINEN
SHOWERS
VESTIBULE
CORRIDOR
FIRST SERGEANTS &
CLERKS OFFICE
C O
M M
A N
D
IN
G O
F F
IC
E
R
E X
E C
U T
IV
E
O F
F
IC
E R
CONFERENCE
STORAGE
UNISEX
ELEC
CLOSET
EF
TRAINING
EQUIPMENT
MAINTENANCE
JAN
UNISEX
NUCLEAR
BIO &
CHEMICAL
COMO
UNIT
STORAGE
ARMS
VAULT
CORRIDOR
JAN
ELEC
CLOSET
TELECOMM
CLOSET
CORRIDOR110
ELEC
STAIR 1
TER
CLOSET
120A
CLOSET
S
H O
W E
R S
TOILET
SHOWERS
TOILET
TOILET
LAVATORIES
*10*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10*10*10*10*10*10
*10 *10 *10 *10
*10
*10
*10
*10 *10
*10
*10
*10
*10
*10
*10*10
*10*10*10*10
*2
*2*2*2
*2 *2*2
*2*2
*2*2*2
*2*2
*2*2
*2*2
*2
*2
*2
*2*2
*2*2
*2*2
*2*2 *2*2
*2*2
*2*2
*2*2
*2*2
*2
*2
*5*5*5
*19*19*19 *5*5 *18
TYP
*18
*5*5
*5*5*5
*19*19*19
*10*10
TYP
*5*5
*5*5*5
*19*19*19
*5*5*5
*5*5
*19 *19
*16*16
*16*16
*16
*16
111A
STAIR 3
117A
STAIR 2
102A
STAIR 4
*21
2.02
*21
*21
TYP
*1
*14
*21
*21
*2
*14
*14
*14
1 2 3 4 5 6 7 8 9 10 11
12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
*18
2.032.03
*2
2.01
2.01
2.01
2.01
2.04 2.01
2.04
2.04
TYP.
2.06
*21
*21
*22
*21
*21
*21
*21
LEGEND (DEMO)
EXISTING DOOR AND FRAME TO REMAIN
EXISTING DOOR AND FRAME TO BE
DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
EXISTING WINDOW TO BE
DEMOLISHED
SCALE: 3/32" = 1'-0"
COMPREHENSIVE FIRST FLOOR DEMOLITION PLAN
NOTES - DEMO PLANS
1 THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2 ALL EQUIPMENT TO REMAIN THE PROPERTY OF
THE GOVERNMENT. ALL EQUIPMENT THE
GOVERNMENT DOES NOT WANT TO KEEP AND
STORE SHALL BECOME THE PROPERTY OF THE
CONTRACTOR.
3 ALL DEMOLITION WORK IS TO BE DONE IN
COMPLIANCE WITH ALL APPLICABLE CODES, LAWS
AND REGULATIONS.
4 PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE OR DISRUPTION OF
OPERATION.
5 SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE
CONTRACTOR SHALL COORDINATE WITH THE
ARCHITECT.
6 ALL ABANDONED MECHANICAL, PLUMBING, AND
ELECTRICAL PIPING IS TO BE REMOVED TO A
POINT BELOW EXISTING CONCRETE FLOOR SLAB,
BEHIND WALLS AND AS CLOSE TO THE CEILING
DECK AS POSSIBLE AND MADE SAFE BY CAPPING.
7 WHERE NECESSARY, SAW-CUT SURFACES TO
PROTECT ADJACENT SURFACES NOT SCHEDULED
FOR DEMOLITION.
8 PATCH ALL INTERIOR AND EXTERIOR WALL
PENETRATIONS TO MATCH EXISTING ADJACENT
FINISHES. PATCH EXISTING WALLS TO REMAIN TO
MAINTAIN FIRE RATINGS INDICATED ON "G"
DRAWINGS. FINISH SHALL BE FLUSH WITH
ADJACENT CONSTRUCTION.
9 NOTIFY CONTRACTING OFFICER REPRESENTATIVE
IF ANY EXISTING ITEM THAT CONFLICTS WITH THE
INTENDED FINAL PRODUCT IS NOT SPECIFICALLY
CALLED OUT FOR DEMOLITION. CONTRACTOR IS
TO NOTIFY CONTRACTING OFFICER
REPRESENTATIVE OF ANY DISCREPANCIES IN THE
DOCUMENTS AND FIELD CONDITIONS BEFORE
PROCEEDING WITH DEMOLITION AND/OR
CONSTRUCTION.
10 SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE
CONTRACTOR SHALL COORDINATE WITH THE
ARCHITECT.
11 REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
12 COORDINATE WITH MECHANICAL, ELECTRICAL,
PLUMBING, AND COMMUNICATIONS DRAWINGS
AND SCOPES OF WORK FOR ADDITIONAL
DEMOLITION REQUIREMENTS.
13 PROVIDE TEMPORARY BARRICADES AND OTHER
FORMS OF PROTECTION AS REQUIRED TO
PROTECT OWNER'S PERSONNEL AND GENERAL
PUBLIC FROM INJURY DUE TO DEMOLITION WORK.
14 ALL DEMOLITION WORK IS TO BE DONE IN
COMPLIANCE WITH ALL APPLICABLE CODES, LAWS
AND REGULATIONS.
15 ALL ABANDONED MECHANICAL, PLUMBING, AND
ELECTRICAL PIPING IS TO BE REMOVED TO A
POINT BELOW EXISTING CONCRETE FLOOR SLAB,
BEHIND WALLS AND AS CLOSE TO THE CEILING
DECK AS POSSIBLE AND MADE SAFE BY CAPPING.
C
B
A
D
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
KEYPLAN
AD110
C O
M P
R E
H E
N S
IV
E
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
P L A
N
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
NOTE: REMOVE EXISTING FLOOR
FINISHES ALL ROOMS THIS FLOOR. PREP
FLOOR FOR POLISHING PROCESS, SEE
INTERIORS SHEETS.
KEYNOTES.
2.02 REMOVE, STORE AND PROTECT EXISTING
WASHERS / DRYERS TO ACCOMMODATE FINISH
WORK IN THIS AREA. REINSTALL MACHINES
AFTER FINISH WORK IS COMPLETE.
2.03 REMOVE, STORE AND PROTECT EXISTING
VENDING MACHINES TO ACCOMMODATE FINISH
WORK IN THIS AREA. REINSTALL MACHINES
AFTER FINISH WORK IS COMPLETE.
2.04 REMOVE, STORE AND PROTECT EXISTING
EXISTING WIRE MESH CAGING TO
ACCOMODATE FINISH WORK IN THIS AREA.
RESINSTALL CAGING AFTER FINISH WORK IS
COMPLETE.
2.06 EXISTING SHAFT SPACE TO REMAIN
KEYNOTES.
*1 REMOVE EXISTING WALLS
*2 REMOVE EXISTING DOOR AND FRAME
ASSEMBLY, TYPICAL
*5 REMOVE EXISTING PLUMBING FIXTURES, SEE
PLUMBING SERIES
*10 REMOVE EXISTING WINDOW ASSEMBLY.
*14 REMOVE EXISTING STAIR RAILINGS
*16 REMOVE EXISTING WALL WAINSCOT PANELING.
SEE INTERIOR SERIES
*18 REMOVE EXISTING SINKS, COUNTERTOPS,
WALL MIRRORS, AND WALL HUNG PAPER
TOWEL DISPENSERS. REMOVE SINK SIDE OF
EXISTING WET WALL FOR PLUMBING WORK.
SEE PLUMBING SERIES.
*19 REMOVE EXISTING TOILET PARTITIONS
*21 REMOVE EXISTING GYP BOARD WALL FINISH TO
STEEL STUD, ROOM IN ENTIRETY. PREP FOR
NEW WALL FINISH. SEE INTERIOR AND
ARCHITECTURAL SERIES.
*22 REMOVE EXISTING GANG SHOWERS CURB AND
FINISHES TO EXISTING STEEL STUDS. PREPARE
WALLS AND FLOORS FOR NEW INDIVIDUAL
SHOWER STALL CONSTRUCTION. SEE
ARCHITECTURAL, INTERIOR, AND PLUMBING
SERIES
2.01 EXISTING TO REMAIN. SEE OTHER DISCIPLINES
FOR WORK IN THIS AREA.
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
*11
*11
*11
*11 *11 *11
*11
*11 *11
2.01 *11
DAY
ROOM
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
LIVING/SLEEPING
BAY
LINEN
L A
V A
T O
R
IE
S
LIVING/SLEEPING
BAY
LINEN
SHOWERS
VESTIBULE
CORRIDOR
FIRST SERGEANTS &
CLERKS OFFICE
COMMANDING
OFFICER
EXECUTIVE
OFFICER 132
CONFERENCE
STORAGE
UNISEX
ELEC
CLOSET
EF
TRAINING
EQUIPMENT
MAINTENANCE
JAN 140
UNISEX
NUCLEAR
BIO &
CHEMICAL 142
COMO
UNIT
STORAGE
ARMS
VAULT
CORRIDOR
JAN
ELEC
CLOSET
TELECOMM
CLOSET
CORRIDOR
ELEC
STAIR 1
TER
CLOSET
120A
CLOSET
S H
O W
E R
S
TOILET
SHOWERS
TOILET
TOILET
LAVATORIES
*122.01
2.01 2.01
2.01
2.01
2.01
2.01
*20*20
*11
2.01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
TYP
2.01
*11
*11
*11
2.01
2.01
2.01
2.012.01
*20*20
TYP
*20*20
*20*20
TYP
TYP
*20*20
*20*20
TYP
TYP
RCP LEGEND
2'x2' ACOUSTICAL CEILING PANEL
PAINTED GYPSUM WALLBOARD CEILING
PAINTED EXPOSED STRUCTURE
DEMO LIGHTING FIXTURES SEE E-SERIES
DEMO ILLUMINATED EXIT SIGN
SEE E-SERIES
DEMO MECHANICAL DIFFUSER SEE M-
SERIES
DEMO MECHANICAL GRILLE SEE M-
SERIES
2'x2' ACOUSTICAL CEILING PANEL (DEMO)
C
B
A
D
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
KEYPLAN
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
AD111
C O
M P
R E
H E
N S
IV
E
F
IR
S T
F L O
O R
D E
M O
L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
SCALE: 3/32" = 1'-0"
COMPREHENSIVE FIRST FLOOR DEMOLITION REFLECTED CEILING PLAN
KEYNOTES
*11 REMOVE EXISTING ACP CEILING, GRID AND
LIGHT FIXTURES. SEE ELECTRICAL SERIES
*12 REMOVE EXISTING GYPSUM BOARD CEILING
AND LIGHT FIXTURES, TYPICAL. (SEE OTHER
DISCIPLINES FOR SCOPE OF WORK)
*20 REMOVE EXISTING LIGHT FIXTURE, SEE
ELECTRICAL
2.01 EXISTING TO REMAIN. SEE OTHER DISCIPLINES
FOR WORK IN THIS AREA.
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
UP
LIVING/SLEEPING
BAY
LINEN
TOILET
SHOWERS
LINEN
LIVING/SLEEPING
BAY
DAY
ROOM
CORRIDOR
SHOWERS
LINEN
LIVING/SLEEPING
BAY
ELEC
CLOSET
TELECOMM
CLOSET
TR
JAN210
ELEC
STAIR 1
CLOSET
CLOSET
L
A V
A T
O R
IE
S
S
H O
W E
R S
TOILET
LAVATORIES
LAVATORIES
TOILET
*10 *10 *10 *10 *10 *10
*10 *10 *10 *10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10 *10
*10
*10
*10
*2
*2
*2*2
*2
*2*2*2
*2
*2*2 *2*2*2
*2
*2
*2*2
*2
*2*2
*5*5*5
*5*5 *19*19*19
*18*18
TYP
*5*5*5
*5*5
TYP
*5*5
*5*5*5
*19*19*19
*10*10
*16
NOTE - REFER TO
GENERAL NOTE 31 ON
SHEET A-001 FOR
DEMOLITION OF
EXISTING ROOF
ASSEMBLY
202A
STAIR 4
211A
STAIR 3
217A
STAIR 2
*14
*14
*14
*14
*21
*21
*21
2.02
1 2 3 4 5 6 7 8 9 10 11
12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
*18
2.01
2.01
2.01
2.06
*21
*21
*21
*21
*21
*21
*22
*22
*2
LEGEND (DEMO)
EXISTING DOOR AND FRAME TO REMAIN
EXISTING DOOR AND FRAME TO BE
DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
EXISTING WINDOW TO BE
DEMOLISHED
NOTES - DEMO PLANS
1 THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2 ALL EQUIPMENT TO REMAIN THE PROPERTY OF
THE GOVERNMENT. ALL EQUIPMENT THE
GOVERNMENT DOES NOT WANT TO KEEP AND
STORE SHALL BECOME THE PROPERTY OF THE
CONTRACTOR.
3 ALL DEMOLITION WORK IS TO BE DONE IN
COMPLIANCE WITH ALL APPLICABLE CODES, LAWS
AND REGULATIONS.
4 PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE OR DISRUPTION OF
OPERATION.
5 SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE
CONTRACTOR SHALL COORDINATE WITH THE
ARCHITECT.
6 ALL ABANDONED MECHANICAL, PLUMBING, AND
ELECTRICAL PIPING IS TO BE REMOVED TO A
POINT BELOW EXISTING CONCRETE FLOOR SLAB,
BEHIND WALLS AND AS CLOSE TO THE CEILING
DECK AS POSSIBLE AND MADE SAFE BY CAPPING.
7 WHERE NECESSARY, SAW-CUT SURFACES TO
PROTECT ADJACENT SURFACES NOT SCHEDULED
FOR DEMOLITION.
8 PATCH ALL INTERIOR AND EXTERIOR WALL
PENETRATIONS TO MATCH EXISTING ADJACENT
FINISHES. PATCH EXISTING WALLS TO REMAIN TO
MAINTAIN FIRE RATINGS INDICATED ON "G"
DRAWINGS. FINISH SHALL BE FLUSH WITH
ADJACENT CONSTRUCTION.
9 NOTIFY CONTRACTING OFFICER REPRESENTATIVE
IF ANY EXISTING ITEM THAT CONFLICTS WITH THE
INTENDED FINAL PRODUCT IS NOT SPECIFICALLY
CALLED OUT FOR DEMOLITION. CONTRACTOR IS
TO NOTIFY CONTRACTING OFFICER
REPRESENTATIVE OF ANY DISCREPANCIES IN THE
DOCUMENTS AND FIELD CONDITIONS BEFORE
PROCEEDING WITH DEMOLITION AND/OR
CONSTRUCTION.
10 SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE
CONTRACTOR SHALL COORDINATE WITH THE
ARCHITECT.
11 REFER TO THE HAZARDOUS MATERIALS REPORT
FOR INFORMATION REGARDING HAZARDOUS
MATERIALS IN THE BUILDING.
12 COORDINATE WITH MECHANICAL, ELECTRICAL,
PLUMBING, AND COMMUNICATIONS DRAWINGS
AND SCOPES OF WORK FOR ADDITIONAL
DEMOLITION REQUIREMENTS.
13 PROVIDE TEMPORARY BARRICADES AND OTHER
FORMS OF PROTECTION AS REQUIRED TO
PROTECT OWNER'S PERSONNEL AND GENERAL
PUBLIC FROM INJURY DUE TO DEMOLITION WORK.
14 ALL DEMOLITION WORK IS TO BE DONE IN
COMPLIANCE WITH ALL APPLICABLE CODES, LAWS
AND REGULATIONS.
15 ALL ABANDONED MECHANICAL, PLUMBING, AND
ELECTRICAL PIPING IS TO BE REMOVED TO A
POINT BELOW EXISTING CONCRETE FLOOR SLAB,
BEHIND WALLS AND AS CLOSE TO THE CEILING
DECK AS POSSIBLE AND MADE SAFE BY CAPPING.
SCALE: 3/32" = 1'-0"
COMPREHENSIVE SECOND FLOOR DEMOLITION PLAN
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
C
B
A
D
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
KEYPLAN
AD120
C O
M P
R E
H E
N S
IV
C
O N
D F
L O
O R
D E
M O
L
IT
IO
N
P L A
N
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
NOTE: REMOVE EXISTING FLOOR
FINISHES ALL ROOMS THIS FLOOR.
PREP FLOOR FOR POLISHING
PROCESS, SEE INTERIORS SHEETS.
KEYNOTES.
2.02 REMOVE, STORE AND PROTECT EXISTING
WASHERS / DRYERS TO ACCOMMODATE FINISH
WORK IN THIS AREA. REINSTALL MACHINES
AFTER FINISH WORK IS COMPLETE.
2.06 EXISTING SHAFT SPACE TO REMAIN
KEYNOTES.
*2 REMOVE EXISTING DOOR AND FRAME
ASSEMBLY, TYPICAL
*5 REMOVE EXISTING PLUMBING FIXTURES, SEE
PLUMBING SERIES
*10 REMOVE EXISTING WINDOW ASSEMBLY.
*14 REMOVE EXISTING STAIR RAILINGS
*16 REMOVE EXISTING WALL WAINSCOT PANELING.
SEE INTERIOR SERIES
*18 REMOVE EXISTING SINKS, COUNTERTOPS,
WALL MIRRORS, AND WALL HUNG PAPER
TOWEL DISPENSERS. REMOVE SINK SIDE OF
EXISTING WET WALL FOR PLUMBING WORK.
SEE PLUMBING SERIES.
*19 REMOVE EXISTING TOILET PARTITIONS
*21 REMOVE EXISTING GYP BOARD WALL FINISH TO
STEEL STUD, ROOM IN ENTIRETY. PREP FOR
NEW WALL FINISH. SEE INTERIOR AND
ARCHITECTURAL SERIES.
*22 REMOVE EXISTING GANG SHOWERS CURB AND
FINISHES TO EXISTING STEEL STUDS. PREPARE
WALLS AND FLOORS FOR NEW INDIVIDUAL
SHOWER STALL CONSTRUCTION. SEE
ARCHITECTURAL, INTERIOR, AND PLUMBING
SERIES
2.01 EXISTING TO REMAIN. SEE OTHER DISCIPLINES
FOR WORK IN THIS AREA.
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
2.01
2.01
2.01
2.01
*20*20
TYP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
J
K
L
M
LIVING/SLEEPING BAY
LINEN
TOILET
SHOWERS
LINEN
LIVING/SLEEPING BAY
DAY ROOM
222CORRIDOR
SHOWERS
LINEN
LIVING/SLEEPING BAY
ELEC CLOSET
TELECOMM
CLOSET
TR
JAN
ELEC
STAIR 1
CLOSET
CLOSET
LAVATORIES
S H
O W
E R
S
TOILET
LAVATORIES
LAVATORIES
TOILET
STAIR 2
217A
STAIR 3
211A
STAIR 4
202A
*11
*11
2.01
2.01
2.01
*11
2.01
2.01
2.01
2.01
2.01
2.01
*20*20
*20*20
*20*20
*20*20
*20*20
TYP
TYP
TYP
TYP
TYP
RCP LEGEND
2'x2' ACOUSTICAL CEILING PANEL
PAINTED GYPSUM WALLBOARD CEILING
PAINTED EXPOSED STRUCTURE
DEMO LIGHTING FIXTURES SEE E-SERIES
DEMO ILLUMINATED EXIT SIGN
SEE E-SERIES
DEMO MECHANICAL DIFFUSER SEE M-
SERIES
DEMO MECHANICAL GRILLE SEE M-
SERIES
2'x2' ACOUSTICAL CEILING PANEL (DEMO)
C
B
A
D
N
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
W Q
R F
W Q
R -1
-D
-0
F O
R T
H U
N T
E R
L
IG
G E
T T
T R
A
IN
IN
G
B A
R R
A C
K S
F U
L L F
A C
IL
IT
Y R
E N
O V
A T
IO
N
B U
IL
D
IN
G
S
A
N D
P N
P
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y
LOUISVILLE DISTRICT
KEYPLAN
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
AD121
C O
M P
R E
H E
N S
IV
E
S E
C O
N D
F L O
O R
D E
M O
L
IT
IO
N
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
D L P
A L B
R M
S
-3
-2
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IS
S
IO
N
J U
L Y
SCALE:
8' - 0" 16' - 0" 32' - 0"
3/32" = 1' - 0"
SCALE: 3/32" = 1'-0"
COMPREHENSIVE SECOND FLOOR DEMOLITION REFLECTED CEILING PLAN
KEYNOTES
*11 REMOVE EXISTING ACP CEILING, GRID AND
LIGHT FIXTURES. SEE ELECTRICAL SERIES
*20 REMOVE EXISTING LIGHT FIXTURE, SEE
ELECTRICAL
2.01 EXISTING TO REMAIN. SEE OTHER DISCIPLINES
FOR WORK IN THIS AREA.
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
CORRIDOR
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
LIVING/SLEEPING
BAY
LINEN
TOILET
LIVING/SLEEPING
BAY
LINEN
LAVATORIES
DAY
ROOM
ELEC
CLOSET
TELECOM
CLOSET
ELEC
JAN 308
TR
STAIR 1
CLOSET
CLOSET
L
A V
A T
O R
IE
S
S
H O
W E
R S
SHOWERS
SHOWERS
TOILET
TOILET
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10
*10*10*10*10*10*10
*10 *10 *10 *10
*2*2 *2 *2*2
*10
*10
*10
*10
*2
*2
*2*2
*2*2
*2*2
*2
*2
*2
*2
*2
*2*2
*5*5*5
*5*5
*19*19*19
*18
TYP
*18*5*5
*5*5*5
*19*19*19
*14
*14
*14
*14
*14
*21
2.02
*21
*21
*14
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
J
K
L
M
*18
TYP.
2.01
2.01
2.01
2.06
*2
*21
*21
*21
*21
*21
*21 LEGEND (DEMO)
EXISTING DOOR AND FRAME TO REMAIN
EXISTING DOOR AND FRAME TO BE
DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
EXISTING WINDOW TO BE
DEMOLISHED
NOTES - DEMO PLANS
1 THE EXISTING BUILDING INFORMATION SHOWN
WAS COMPILED FROM DRAWINGS FURNISHED BY
THE GOVERNMENT. THESE DRAWINGS WERE
NOTED AS AS-BUILT DRAWINGS. ACTUAL
CONDITIONS MAY VARY. CONTRACTOR IS TO
VERIFY ALL CONDITIONS PRIOR TO START OF
WORK.
2 ALL EQUIPMENT TO REMAIN THE PROPERTY OF
THE GOVERNMENT. ALL EQUIPMENT THE
GOVERNMENT DOES NOT WANT TO KEEP AND
STORE SHALL BECOME THE PROPERTY OF THE
CONTRACTOR.
3 ALL DEMOLITION WORK IS TO BE DONE IN
COMPLIANCE WITH ALL APPLICABLE CODES, LAWS
AND REGULATIONS.
4 PROTECT ADJACENT AREAS FROM DUST,
EXCESSIVE NOISE OR DISRUPTION OF
OPERATION.
5 SHOULD HIDDEN FIELD CONDITIONS REQUIRE
MODIFICATIONS TO THE LAYOUT, THE
CONTRACTOR SHALL COORDINATE WITH THE
ARCHITECT.
6 ALL ABANDONED MECHANICAL, PLUMBING, AND
ELECTRICAL PIPING IS TO BE REMOVED TO A
POINT…