W912QR20R0057Plans_Vol2-0000.pdf
PDF 22 MB Posted
- Solicitation number
- W912QR20R0057
About this file
This document describes a federal contract opportunity for the construction of a middle school at Fort Campbell, Kentucky. The project involves renovating and adding onto an existing high school to convert it into a middle school totaling approximately 167,000 square feet, including 126,000 square feet of new construction and 41,000 square feet of renovation. The scope of work also includes around 69,000 square feet of demolition. The contract value is estimated between $25-100 million. The solicitation will be a single-phase acquisition utilizing a best value tradeoff source selection process. The contract type will be firm-fixed-price for a duration of 950 calendar days from notice to proceed. Offerors must be registered in the System for Award Management database and have an active registration representing any joint ventures. The point of contact for inquiries is listed.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SEALS AND SIGNATURES
ARCHITECTURE HAZARDOUS
MATERIALS
STRUCTURAL CIVIL
FIRE PROTECTION/
LIFE SAFETY
PLUMBING &
MECHANICAL
ELECTRICAL
POWER & LIGHTING
TECHNOLOGY
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
US Army Corps of Engineers ®
P2 NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
G-001.1
C O
V E
R S
H E
E T
V
O L
U M
E
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
W T
S
W T
S
W T
S
W A
T
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
LOUISVILLE DISTRICT
372494
11 MARCH 2020
FORT CAMPBELL, KY
FORT CAMPBELL MIDDLE SCHOOL
AM00029
VICINITY MAP LOCATION MAP
PROJECT LOCATION PROJECT LOCATION
WALLER, TODD & SADLER ARCHITECTS, INC.
ARCHITECTURE / INTERIOR DESIGN
FANNING HOWEY ASSOCIATES, INC.
PME ENGINEERS / A/V ENGINEERS
SPEIGHT, MARSHALL & FRANCIS, P.C.
STRUCTURAL ENGINEERS
KIMLEY HORN
CIVIL ENGINEERS
JENSEN HUGHES
FIRE AND LIFE SAFETY
GEOENVIRONMENTAL RESOURCES
HAZMAT
4500 MAIN STREET
VIRGINIA BEACH, VA 23462
(757) 213-8600
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
(757) 417-0140
1228 PERIMETER PARKWAY, SUITE 201
VIRGINIA BEACH, VA 23454
(757) 427-1020
350 EAST NEW YORK STREET, SUITE 300
INDIANAPOLIS, IN 46204
(317) 848-0966
2712 SOUTHERN BOULEVARD, UNIT 101
VIRGINIA BEACH, VA 23452
(757) 463-3200
2712 COMMERCE DRIVE, SUITE 817
BALTIMORE, MD 21227
(410) 737-8677
FOODSERVICE CONSULTANTS STUDIO, INC
FOODSERVICE
3420 PUMP ROAD, #158
HENRICO, VA 23233
(804) 550-2090
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
029 June 2020
W912QR20R0057
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
G-002.1
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
W T
S
W T
S
W T
S
W A
T
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
INDEX OF DRAWINGS - VOLUME 2
SHEET # SHEET TITLE
S-145 HIGH ROOF FRAMING PLAN - AREA G
S-146 HIGH ROOF FRAMING PLAN - AREA H
S-147 HIGH ROOF FRAMING PLAN - AREA J
S-148 HIGH ROOF FRAMING PLAN - AREA K
S-201 FIREWALL PORTAL ELEVATION
S-202 FIREWALL PORTAL DETAILS
S-203 FIREWALL PORTAL DETAILS
S-301 FOUNDATION SECTIONS
S-302 FOUNDATION SECTIONS
S-303 FOUNDATION SECTIONS
S-304 FOUNDATION SECTIONS
S-311 FRAMING SECTIONS
S-312 FRAMING SECTIONS
S-313 FRAMING SECTIONS
S-314 FRAMING SECTIONS
S-315 FRAMING SECTIONS
S-316 FRAMING SECTIONS
S-317 FRAMING SECTIONS
S-318 FRAMING SECTIONS
S-319 FRAMING SECTIONS
S-321 FRAMING SECTIONS
S-322 FRAMING SECTIONS
S-323 FRAMING SECTIONS
S-324 FRAMING SECTIONS
S-325 FRAMING SECTIONS
S-402 OPERABLE PARTITION FRAMING PLAN - AREA G
S-403 OPERABLE PARTITION FRAMING PLAN - AREA H
S-404 OPERABLE PARTITION FRAMING PLAN - AREA K
S-405 GATHERING STAIR FRAMING PLAN - AREA F, SECTIONS AND DETAILS
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
S-503 TYPICAL DETAILS
S-504 TYPICAL DETAILS
S-505 TYPICAL DETAILS
S-506 TYPICAL DETAILS
S-507 TYPICAL DETAILS
S-508 TYPICAL DETAILS
S-509 TYPICAL DETAILS
S-510 TYPICAL DETAILS
S-511 TYPICAL DETAILS
S-512 TYPICAL DETAILS
S-513 SPECIAL CONNECTION DETAILS
AD100 OVERALL FIRST FLOOR PLAN - DEMOLITION
AD101 FIRST FLOOR PLAN - AREA A - DEMOLITION
AD102 FIRST FLOOR PLAN - AREA B - DEMOLITION
AD103 FIRST FLOOR PLAN - AREA C - DEMOLITION
AD104 FIRST FLOOR PLAN - AREA D - DEMOLITION
AD105 OVERALL MEZZANINE FLOOR PLAN - DEMOLITION
AD106 MEZZANINE FLOOR PLAN - AREA A - DEMOLITION
AD107 MEZZANINE FLOOR PLAN - AREA C - DEMOLITION
AD108 OVERALL ROOF PLAN - DEMOLITION
AD109 OVERALL EXTERIOR ELEVATIONS - DEMOLITION
AD110 DEMOLITION WALL SECTIONS
AD111 DEMOLITION WALL SECTIONS
AD112 DEMOLITION WALL SECTIONS
AD113 DEMOLITION WALL SECTIONS
AD114 DEMOLITION WALL SECTIONS
VOLUME 1 - TOTAL SHEETS: 115
INDEX OF DRAWINGS - VOLUME 2
SHEET # SHEET TITLE
G-001.1 COVER SHEET - VOLUME 2
G-002.1 INDEX OF DRAWINGS - VOLUME 2
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
S-003 STRUCTURAL NOTES AND ABBREVIATIONS
S-010 WALL REINFORCING PLAN - AREAS A, B, C AND D
S-011 WALL REINFORCING PLAN - AREAS E, F, G, H, J AND K
S-020 DIMENSION PLAN - OVERALL
S-021 DIMENSION PLAN - AREA A
S-022 DIMENSION PLAN - AREA B
S-023 DIMENSION PLAN - AREA C
S-024 DIMENSION PLAN - AREA D
S-025 DIMENSION PLAN - AREA E
S-026 DIMENSION PLAN - AREA F
S-027 DIMENSION PLAN - AREA G
S-028 DIMENSION PLAN - AREA H
S-029 DIMENSION PLAN - AREA J
S-030 DIMENSION PLAN - AREA K
S-040 FOUNDATION LOADING AND SUBGRADE IMPROVEMENT PLAN - AREAS A, B, C AND D
S-041 FOUNDATION LOADING AND SUBGRADE IMPROVEMENT PLAN - AREAS E, F, G, H, J AND K
S-050 ROOF SNOW LOADING PLAN
SD111 FOUNDATION PLAN - AREA A - DEMOLITION
SD112 FOUNDATION PLAN - AREA B - DEMOLITION
SD113 FOUNDATION PLAN - AREA C - DEMOLITION
SD114 FOUNDATION PLAN - AREA D - DEMOLITION
SD121 MEZZANINE FRAMING PLAN - AREAS A AND C - DEMOLITION
SD132 LOW ROOF FRAMING PLAN - AREA A - DEMOLITION
SD133 LOW ROOF FRAMING PLAN - AREA B - DEMOLITION
SD134 LOW ROOF FRAMING PLAN - AREA D - DEMOLITION
SD141 HIGH ROOF FRAMING PLAN - AREA C - DEMOLITION
S-110 FOUNDATION PLAN KEYNOTES AND LEGEND
S-111 FOUNDATION PLAN - AREA A
S-112 FOUNDATION PLAN - AREA B
S-113 FOUNDATION PLAN - AREA C
S-114 FOUNDATION PLAN - AREA D
S-115 FOUNDATION PLAN - AREA E
S-116 FOUNDATION PLAN - AREA F
S-117 FOUNDATION PLAN - AREA G
S-118 FOUNDATION PLAN - AREA H
S-119 FOUNDATION PLAN - AREA J
S-120 FOUNDATION PLAN - AREA K
S-121 FOUNDATION PLAN - SITE WALLS
S-122 FOUNDATION PLAN - BUS AND MAIN ENTRANCE CANOPIES
S-130 FRAMING PLAN KEYNOTES AND LEGENDS
S-131 LOW AND HIGH ROOF FRAMING PLANS - AREA A
S-132 LOW ROOF FRAMING PLAN - AREA B
S-133 SECOND FLOOR FRAMING PLAN - AREA C
S-134 LOW ROOF FRAMING PLAN - AREA D
S-135 SECOND FLOOR FRAMING PLAN - AREA E
S-136 SECOND FLOOR FRAMING PLAN - AREA F
S-137 SECOND FLOOR FRAMING PLAN - AREA G
S-138 SECOND FLOOR FRAMING PLAN - AREA H
S-139 SECOND FLOOR FRAMING PLAN - AREA J
S-140 SECOND FLOOR FRAMING PLAN - AREA K
S-141 HIGH ROOF FRAMING PLAN - AREA C
S-142 HIGH ROOF FRAMING PLAN - AREA D
S-143 HIGH ROOF FRAMING PLAN - AREA E
S-144 HIGH ROOF FRAMING PLAN - AREA F
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
FOUNDATION NOTES:
FOUNDATIONS FOR THIS STRUCTURE HAVE BEEN DESIGNED IN ACCORDANCE
WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL EXPLORATION REPORT,
PREPARED BY TERRACON CONSULTANTS, INC., DATED AUGUST 20, 2018.
FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE BEARING PRESSURE
PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS
SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER TO EXPLORE THE
EXTENT OF LOOSE, SOFT OR OTHERWISE UNSATISFACTORY SOIL MATERIAL AND
TO VERIFY DESIGN BEARING PRESSURE. THE GEOTECHNICAL ENGINEER WILL
PROVIDE DIRECTION FOR CORRECTIVE ACTION WHERE REQUIRED.
NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST WALLS UNLESS WALLS
ARE SECURELY BRACED AGAINST OVERTURNING, EITHER BY TEMPORARY
CONSTRUCTION BRACING OR BY PERMANENT CONSTRUCTION.
CAST-IN-PLACE CONCRETE NOTES:
CAST-IN-PLACE CONCRETE FOR THIS STRUCTURE HAS BEEN DESIGNED IN
ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-14) AND COMMENTARY
(ACI 318R-14)".
CONCRETE SHALL BE NORMAL WEIGHT AND SHALL OBTAIN 28 DAY COMPRESSIVE
STRENGTHS AS FOLLOWS:
REINFORCING MATERIALS SHALL BE AS FOLLOWS:
REINFORCING BARS - ASTM A615, GRADE 60, DEFORMED.
WELDED WIRE FABRIC - ASTM A185, WELDED STEEL WIRE FABRIC. SHEET
TYPE - ROLLED TYPE NOT ACCEPTABLE.
ALL REINFORCING STEEL AND EMBEDDED ITEMS SHALL BE ACCURATELY PLACED
IN THE POSITIONS SHOWN AND ADEQUATELY TIED AND SUPPORTED BEFORE
CONCRETE IS PLACED TO PREVENT DISPLACEMENT BEYOND PERMITTED
TOLERANCES.
MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS INDICATED ON THE
DRAWINGS SHALL GOVERN WHEN IN CONFLICT WITH ACI 318-14.
UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS:
LAP SPLICE LENGTHS SHALL COMPLY WITH 'CAST-IN-PLACE CONCRETE
REINFORCING BAR LAP SPLICE SCHEDULE' ON SHEET S-002
USE TENSION BAR LAP SPLICE LENGTHS
SPLICES MAY BE MADE WITH MECHANICAL SPLICES (AT CONTRACTOR'S
OPTION). MECHANICAL SPLICES SHALL BE:
SUBMITTED FOR REVIEW
STAGGERED A MINIMUM OF 24" ALONG THE LONGITUDINAL AXIS
OF ADJACENT BARS.
CONCRETE MASONRY NOTES:
CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 AND BE MADE WITH
LIGHTWEIGHT AGGREGATE. THE COMPRESSIVE STRENGTH OF MASONRY, F'm, EXPRESSED AS FORCE PER UNIT OF NET CROSS-SECTIONAL AREA, SHALL BE
2,000 PSI AT 28 DAYS.
REINFORCING STEEL SHALL COMPLY WITH ASTM A615, GRADE 60. SHOP
FABRICATE REINFORCING BARS WHICH ARE SHOWN TO BE BENT OR HOOKED.
GROUT SHALL COMPLY WITH ASTM C476, AND SHALL BE PROPORTIONED TO
OBTAIN A 28 DAY COMPRESSIVE STRENGTH OF 2,000 PSI.
MORTAR SHALL COMPLY WITH ASTM C270, TYPE S OR M. AGGREGATE FOR
MORTAR SHALL COMPLY WITH ASTM C144. AGGREGATE FAILING TO COMPLY
WITH ASTM C144 GRADATION REQUIREMENTS MAY BE USED PROVIDED THE
MORTAR CAN BE PREPARED TO COMPLY WITH THE AGGREGATE RATIO, WATER
RETENTION, AND COMPRESSIVE STRENGTH REQUIREMENTS OF THE PROPERTY
SPECIFICATIONS OF ASTM C270. USE TYPE M BELOW GRADE AND TYPE S ABOVE
GRADE (UNLESS CELLS ARE GROUTED SOLID).
VERTICAL REINFORCING BARS SHALL BE THE GIVEN SIZE AND SPACING SHOWN.
LAP REINFORCING AT ALL SPLICES AS FOLLOWS:
#4 - 25" #5 - 31"
REBAR DOWELS SHALL BE THE SAME SIZE AND SPACING AS VERTICAL
REINFORCING FROM FOUNDATION. DOWELS SHALL HAVE STANDARD ACI HOOKS.
DISCONTINUE ALL HORIZONTAL REINFORCING AT CONTROL JOINTS EXCEPT FOR
THE BOND BEAMS AT JOIST BEARING ELEVATIONS. HORIZONTAL BOND BEAMS
SHALL HAVE CONTINUOUS REINFORCING AS SHOWN IN THE SECTIONS AND
DETAILS.
HORIZONTAL JOINT REINFORCING SHALL BE STANDARD 9 GAGE LADDER TYPE IN
CMU WALLS AT 16" ON-CENTER. JOINT REINFORCING SHALL COMPLY WITH ASTM
A951 AND BE HOT-DIPPED GALVANIZED ACCORDING TO ASTM A153, CLASS B.
VERTICAL REINFORCING SHALL HAVE BAR POSITIONERS AT SPACING NOT TO
EXCEED 200 BAR DIAMETERS, AT GROUT LIFT HEIGHTS, OR BAR SPLICE
LOCATIONS, WHICHEVER IS LESS.
STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:
STRUCTURAL STEEL W- AND WT-SHAPES - ASTM A992, Fy=50 KSI RECTANGULAR AND SQUARE HSS - ASTM A500, GRADE B, Fy=46 KSI
ANCHOR RODS - ASTM F1554, GRADE 36 (WELDABLE)
HEADED STUDS - ASTM A 108, GRADES 1015 THROUGH 1020, TYPE B, Fu=65 KSI
ALL OTHER STRUCTURAL STEEL SHAPES, PLATES AND BARS - ASTM A36,
Fy=36 KSI (UNLESS OTHERWISE NOTED)
THE SUPPORTED FLOORS FOR THIS STRUCTURE HAVE BEEN DESIGNED IN
ACCORDANCE WITH THE AISC SPECIFICATIONS FOR UNSHORED PARTIAL
COMPOSITE CONSTRUCTION.
UNLESS OTHERWISE NOTED, ALL BEAM CONNECTIONS SHALL BE ACCORDING TO
"TYPICAL BOLTED WEB PLATE CONNECTION DETAILS" ON SHEET S-509 USING
ASTM A325 BOLTS.
HIGH STRENGTH BOLTS MAY BE TIGHTENED TO THE "SNUG TIGHT" CONDITION IN
LIEU OF FULL PRETENSIONING.
WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING
CODE - STEEL". WELD ELECTRODES SHALL BE E70XX. CONTINUOUS 3/16"
FILLET WELDS ARE REQUIRED UNLESS OTHERWISE NOTED.
SEE THE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR ADDITIONAL STEEL (IF ANY) NOT SHOWN ON THE STRUCTURAL
DRAWINGS.
UNLESS OTHERWISE NOTED, THE TOP OF ALL STEEL COLUMNS SHALL HAVE A
STEEL CAP PLATE. UNLESS OTHERWISE DETAILED OR NOTED, MINIMUM CAP
PLATE DIMENSIONS SHALL MATCH COLUMN WIDTH AND DEPTH, AND MINIMUM
THICKNESS OF CAP PLATE SHALL EQUAL COLUMN WEB THICKNESS (1/2" MIN).
STRUCTURAL STEEL NOTED TO BE GALVANIZED SHALL CONFORM TO ASTM A123
OR ASTM A153. GALVANIZE AFTER FABRICATION WHERE PRACTICAL. REPAIR
DAMAGED GALVANIZED COATING USING ASTM A780 ZINC-RICH PAINT.
STEEL JOIST NOTES:
STEEL JOISTS SHALL CONFORM TO THE LATEST EDITION OF THE STEEL JOIST
INSTITUTE (SJI) STANDARD SPECIFICATIONS.
PREPARE AND SUBMIT FOR REVIEW SHOP DRAWINGS SHOWING THE LAYOUT OF
JOIST MEMBERS, SPECIAL CONNECTIONS, JOINING AND ACCESSORIES. INCLUDE
MARK, NUMBER, TYPE, LOCATION AND SPACING OF JOISTS AND BRIDGING.
THE JOIST MANUFACTURER SHALL BE RESPONSIBLE FOR CONTINUOUS JOIST
BRIDGING LINES SATISFYING THE REQUIREMENTS OF THE SJI SPECIFICATION
FOR THE TOP AND BOTTOM CHORDS OF ALL STEEL JOISTS, AS WELL AS ANY
ADDITIONAL BRIDGING / BRACING SHOWN ON THE DRAWINGS OR REQUIRED FOR
JOISTS SUBJECTED TO NET UPLIFT OR OTHER SPECIAL LOADS. ALL REQUIRED
JOIST BRIDGING SHALL BE CLEARLY INDICATED ON THE SHOP DRAWINGS.
CROSS-BRIDGING IS REQUIRED AT CHANGES OF JOIST DEPTHS AND AT ENDS OF
ALL BRIDGING LINES UNLESS SUCH ENDS ARE PROPERLY ANCHORED INTO
INTERSECTING INTERIOR OR END WALLS. ALL BRIDGING AND BRIDGING
ANCHORS SHALL BE COMPLETELY INSTALLED BEFORE PLACING OF ANY
CONSTRUCTION LOADS ON THE JOISTS.
ROOF JOISTS SHALL BE DESIGNED FOR A NET UPLIFT LOAD OF 25 PSF. ONE-
THIRD STRESS INCREASE NOT PERMITTED FOR LOAD COMBINATIONS INVOLVING
WIND PER IBC SECTION 1605.3.1.1.
WHERE JOIST SPAN EQUALS 40 FEET OR GREATER JOIST SHALL BE ERECTION
BOLTED TO STEEL BEAM UNLESS PANELIZED JOIST ERECTION IS EMPLOYED.
GENERAL CONTRACTOR SHALL COORDINATE BOLT HOLE LOCATIONS REQUIRED
IN STRUCTURAL STEEL MEMBERS.
CONCENTRATED LOADS NOT LOCATED AT JOIST PANEL POINTS SHALL BE
REINFORCED PER 'TYPICAL DETAIL AT CONCENTRATED LOADS ON JOISTS'.
UNLESS OTHERWISE NOTED ON THE FRAMING PLANS, JOIST SEAT DEPTHS
SHALL BE AS FOLLOWS:
3-1/2" DEEP SEATS AT 'K' SERIES JOISTS (UNLESS OTHERWISE NOTED
1.
2.
3.
4.
5.
SLAB-ON-GRADE 3,500 PSI
SUPPORTED FLOOR SLABS 4,000 PSI
COLUMNS, PEDESTALS AND WALLS 4,000 PSI
FOOTINGS 3,000 PSI
GENERAL NOTES:
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS
OF THE INTERNATIONAL BUILDING CODE, 2015 EDITION, AND THE INTERNATIONAL
CRITERIA, AND AS FOLLOWS.
THE WORK UNDER THE FOLLOWING SPECIFICATION SECTIONS IS SUBJECT TO
SPECIAL INSPECTIONS AS DESCRIBED IN SECTION 1704 OF THE INTERNATIONAL
BUILDING CODE, 2015 EDITION.
312000 - EARTHWORK
033000 - CAST-IN-PLACE CONCRETE
042000 - UNIT MASONRY
051200 - STRUCTURAL STEEL
052100 - STEEL JOISTS
053100 - STEEL DECK
054000 - COLD-FORMED METAL FRAMING
THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY SHORING AND
BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER
ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL BRACING ARE IN PLACE.
BEFORE PROCEEDING WITH WORK WITHIN THE EXISTING STRUCTURE THE
CONTRACTOR SHALL BECOME FAMILIAR WITH THE EXISTING STRUCTURAL
CONDITIONS. THE SHORING AND BRACING SHOWN IS A PARTIAL AND SCHEMATIC
REPRESENTATION OF THAT REQUIRED. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE DESIGN AND ERECTION OF ALL SAFEGUARDS
NECESSARY TO PROTECT THE EXISTING STRUCTURE FROM DAMAGE.
THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, AND
OTHER REQUIREMENTS NECESSARY FOR THE PROPER CONSTRUCTION AND
ALIGNMENT OF THE NEW PORTIONS OF THE STRUCTURE TO THE EXISTING. THE
CONTRACTOR SHALL MAKE ALL MEASUREMENTS NECESSARY FOR FABRICATION
AND ERECTION OF STRUCTURAL MEMBERS.
THE PROJECT SPECIFICATIONS ARE NOT SUPERSEDED BY THE STRUCTURAL
NOTES BUT ARE INTENDED TO BE COMPLEMENTARY TO THEM. REFER TO THE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS IN EACH SECTION.
SPECIFIC NOTES AND SPECIFIC DETAILS ON THE DRAWINGS SHALL TAKE
PRECEDENCE OVER STRUCTURAL NOTES AND TYPICAL DETAILS.
CONSULTANTS' DRAWINGS, INCLUDING STRUCTURAL DRAWINGS, ARE
CONSIDERED SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. ANY
OMISSIONS OR CONFLICTS, INCLUDING DIMENSIONS, BETWEEN VARIOUS
ELEMENTS OF THE CONSULTANTS' DRAWINGS AND/OR SPECIFICATIONS SHALL
BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING
WITH THE WORK.
LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS:
LIVE LOADS:
(PLUS 15 PSF PARTITION ALLOWANCE)
SNOW DESIGN DATA:
WIND DESIGN DATA:
COMPONENTS AND CLADDING DESIGN PRESSURES
SEISMIC DESIGN DATA:
MECHANICAL UNIT WEIGHTS AND LOCATIONS SHOWN ON THE PLANS ARE
APPROXIMATE. CONTRACTOR SHALL VERIFY LOCATIONS AND WEIGHTS SHOWN
AND REPORT DISCREPANCIES TO THE ARCHITECT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
SLAB-ON-GRADE 100 PSF
CLASSROOMS 40 PSF
OFFICES 50 PSF
LOBBIES 100 PSF
80 PSFCORRIDORS ABOVE FIRST FLOOR
CORRIDORS ON FIRST FLOOR 100 PSF
STAIRWAYS 100 PSF
ROOF 20 PSF
STORAGE 125 PSF
MECHANICAL SPACE 150 PSF
15 PSFGROUND SNOW LOAD
EXPOSURE FACTOR 0.9
SNOW IMPORTANCE FACTOR 1.1
THERMAL FACTOR 1.0
ROOF SLOPE FACTOR 1.0
ULTIMATE WIND SPEED 120 MPH
WIND EXPOSURE C
BUILDING RISK CATEGORY III
INTERNAL PRESSURE COEFFICIENT ±0.18
(SEE COMPONENT AND CLADDING LEGEND ON SHEET S-002)
BUILDING RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR 1.25
SS 0.49g S1 0.20g
SITE CLASS C
SDS 0.392g SD1 0.213g
SEISMIC DESIGN CATEGORY D
DESIGN BASE SHEAR 76 KIPS
SEISMIC RESPONSE COEFFICIENT 0.245
RESPONSE MODIFICATION FACTOR 2
A.
B.
C.
D.
GENERAL NOTES (CONTINUED):
CAPABLE OF RESISTING 125% OF THE TENSION CAPACITY OF THE
POSITIVE-CONNECTING TYPE COUPLERS
SPLICED BAR
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
A.
B.
C.
D.
A.
B.
BASIC SEISMIC-FORCE-RESISTING SYSTEM IS SPECIAL REINFORCED
MASONRY SHEAR WALLS AND SPECIAL REINFORCED CONCRETE
SHEARWALLS
FROST LINE DEPTH IS 22" BELOW GRADE. BOTTOM OF ALL EXTERIOR FOUNDATIONS
SHALL BE A MINIMUM OF 22" BELOW EXTERIOR FINISHED GRADE ELEVATION.
CONCRETE MASONRY FOR THIS STRUCTURE HAS BEEN DESIGNED IN
ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES" ACI 530-13 / ASCE 5-13 / TMS 402- 13.
CONCRETE MASONRY CONSTRUCTION SHALL CONFORM TO THE "SPECIFICATIONS
FOR MASONRY STRUCTURES" ACI 530.1-13 / ASCE 6-13 / TMS 602-13.
#6 - 52"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
C.
D.
E.
1.
2.
3.
4.
5.
6.
7.
A.
UFC 1-200-01 (1 NOV 2018) GENERAL BUILDING REQUIREMENTS, WITH CHANGE 2
UFC 3-220-01 (1 NOV 2012) GEOTECHNICAL ENGINEERING
UFC 3-301-01 (1 NOV 2018) STRUCTURAL ENGINEERING, WITH CHANGE 4
UFC 3-310-04 (1 NOV 2018) SEISMIC DESIGN OF BUILDINGS, WITH CHANGE 1
A.
B.
C.
D.
E.
F.
G.
CONCRETE NOT OTHERWISE NOTED 3,000 PSIE.
IN ADDITION TO THE REFERENCES LISTED ABOVE, THE STRUCTURE HAS BEEN
DESIGNED IN ACCORDANCE WITH ASCE 7-10 'MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES'.
AT ALL CONDITIONS AT WHICH THE BELOW GRADE FOUNDATION WALL CONSISTS
OF CONCRETE MASONRY UNITS, GROUT ALL CELLS SOLID BELOW FINISHED FLOOR
AND GRADE ELEVATIONS.
FLAT ROOF SNOW LOAD 16.5 PSF
A.
B.
C.
D.
A.
COLD-FORMED METAL FRAMING NOTES:
ANALYSIS PROCEDURE SIMPLIFIED
OF 3,000 PSF IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE
GEOTECHNICAL REPORT. THE BEARING PRESSURE SHALL BE ACHIEVED BY UTILIZING
A STONE COLUMN AND / OR RAMMED AGGREGATE PIER AND SOIL IMPROVEMENT
SYSTEM CAPABLE OF PROVIDING THE DESIGN SOIL PRESSURE. SEE SHEET S-040
ON PLAN)
COLD-FORMED METAL FRAMING FOR THIS STRUCTURE SHALL BE DESIGNED IN
ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "COLD-
FORMED STEEL DESIGN MANUAL". THE CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS PREPARED BY A PROFESSIONAL ENGINEER FOR THE DESIGN OF
COLD-FORMED METAL FRAMING, INCLUDING DESIGN LOADINGS AND REACTIONS
APPLIED TO THE SUPPORTING STRUCTURE.
COLD-FORMED METAL FRAMING (SIZES/GAGES) AND CONNECTIONS INDICATED
ON DRAWINGS ARE FOR PRICING PURPOSES ONLY. COLD-FORMED ENGINEER
SHALL DESIGN AND DETAIL MEMBERS AND THEIR CONNECTIONS.
COLD-FORMED METAL FRAMING MEMBERS SHALL BE FORMED OF CORROSION-
RESISTANT STEEL CONFORMING TO ASTM A653 WITH A MINIMUM YIELD
STRENGTH OF 33 KSI FOR TRACKS AND RUNNERS AND 33 KSI (50 KSI FOR 54 MILS
16 GAGE AND HEAVIER) FOR ALL OTHER MEMBERS.
WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING
CODE - SHEET STEEL".
COLD-FORMED METAL FRAMING MEMBER SIZES AND GAGES INDICATED ARE IN
ACCORDANCE WITH THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA)
NOMENCLATURE.
COLD-FORMED METAL FRAMING MEMBERS SHALL BE DESIGNED FOR THE LOADS
GIVEN IN THE GENERAL NOTES. THE DESIGN LOADS ARE UNFACTORED SERVICE
LOADS, ALL APPLICABLE FACTORS SHALL BE APPLIED.
MAXIMUM LATERAL DEFLECTION OF COLD-FORMED FRAMING MEMBERS SHALL BE
DETERMINED BY THE FOLLOWING TABLE:
COLD-FORMED METAL FRAMING MEMBERS SHALL BE DESIGNED FOR ALL
FRAMING CONDITIONS FOUND IN THE STRUCTURE, INCLUDING WALLS, CORNERS,
HEADERS, AND JAMBS. SOME CONDITIONS MAY REQUIRE MODIFICATION OF
COLD-FORMED FRAMING MEMBERS (SUCH AS NOTCHING OR REVISING SIZES) OR
MULTIPLE STUDS TO SUPPORT INCREASED LOADS. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO COORDINATE ALL CONDITIONS AND DETAILS.
CROSS BRIDGING OR FULL-DEPTH BLOCKING IS REQUIRED AT WALL STUDS NOT
RECEIVING SHEATHING ON BOTH FACES. UNLESS OTHERWISE INDICATED, MAXIMUM
BRIDGING/BLOCKING SPACING SHALL BE 8'-0" o/c OR AT 1/3 POINTS OF MEMBER
SPAN, WHICHEVER IS LESS. COORDINATE EXTENTS OF WALL AND CEILING
SHEATHING WITH THE ARCHITECTURAL DRAWINGS.
COLD-FORMED METAL FRAMING CONNECTIONS TO THE STRUCTURE SHALL BE
DESIGNED FOR ALL FRAMING CONDITIONS. CONNECTIONS ARE SCHEMATICALLY
SHOWN ON THE STRUCTURAL DRAWINGS. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE ALL CONNECTION CONDITIONS AND LOCATIONS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
STUD USE L/y RATIO (LIMIT)
BACKING UP MASONRY L/600 (0.4 IN)
BACKING UP METAL PANEL L/360 (MANUF. RECOMMENDATION)
STRUCTURAL STEEL NOTES:
STRUCTURAL STEEL FOR THIS STRUCTURE HAS BEEN DESIGNED IN
ACCORDANCE WITH THE THIRTEENTH EDITION OF THE AMERICAN INSTITUTE OF
STEEL CONSTRUCTION (AISC 360-10) "STEEL CONSTRUCTION MANUAL" -
ALLOWABLE STRESS DESIGN.
1.
EXISTING BUILDING CODE, 2015 EDITION AS ADOPTED BY THE UNITED FACILITIES
UFC 4-010-01 (12 DEC 2018) DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGSE.
AND S-041 FOR FOUNDATION LOADS AND DESIGN CRITERIA.
SNOW DRIFT SEE SHEET S-050
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-001
S T
R U
C T
U R
A L
N O
T E
S
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R , T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C Y
P R
E S
S A
V E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
JC
S
/D W
S
M A
R C
H
A M
-3
-C W
T S
P R
O
JE
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
ADHESIVE ANCHOR
CAPACITY SCHEDULE
STEEL DECK NOTES:
STEEL DECK SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN IRON
AND STEEL INSTITUTE (AISI), "SPECIFICATION FOR THE DESIGN OF COLD-FORMED
STEEL STRUCTURAL MEMBERS" AND THE STEEL DECK INSTITUTE (SDI), "DESIGN
MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS."
STEEL DECK UNITS SHALL COMPLY WITH THE FOLLOWING:
1-1/2" ROOF DECK SHALL BE 18 GAGE PAINTED TYPE B RIB DECK SPANNING
PERPENDICULAR TO SUPPORTS UNLESS OTHERWISE NOTED. ATTACH
DECK TO STRUCTURAL STEEL SUPPORTS WITH 5/8" DIAMETER PUDDLE
WELDS AT EVERY RIB, INCLUDING RIBS WHERE SIDELAPS OCCUR. FASTEN
ADJACENT DECK UNITS WITH #10 SELF-TAPPING HEX HEAD SCREWS AT 1/10
POINTS BETWEEN SUPPORTS ALONG SIDELAPS AND FASTEN EDGEMOST
DECK PANEL TO STEEL FRAMING WITH 5/8" DIAMETER PUDDLE WELDS AT
SAME SPACING AS SIDELAP FASTENERS.
2" COMPOSITE DECK SHALL BE 20 GAGE GALVANIZED TYPE VLI
COMPOSITE FLOOR DECK SPANNING PERPENDICULAR TO SUPPORTS
UNLESS OTHERWISE NOTED. ATTACH DECK TO STRUCTURAL STEEL
SUPPORTS WITH 5/8" DIAMETER PUDDLE WELDS AT EVERY OTHER RIB
INCLUDING RIBS WHERE SIDELAPS OCCUR. FASTEN ADJACENT DECK
UNITS WITH #10 SELF-TAPPING HEX HEAD SCREWS AT 1/4 POINTS BETWEEN
SUPPORTS ALONG SIDELAPS AND FASTEN EDGEMOST DECK PANEL TO STEEL
FRAMING WITH 5/8" DIAMETER PUDDLE WELDS AT SAME SPACING AS
SIDELAP FASTENERS. ALL COMPOSITE DECK IS DESIGNED TO BE THREE
SPAN CONTINUOUS UNLESS OTHERWISE NOTED ON PLAN.
SHEAR CONNECTORS FOR COMPOSITE FLOOR SYSTEMS SHALL BE 3/4"
DIAMETER x 4" LONG HEADED STUDS, CONFORMING TO ASTM A 108, GRADES 1015 THROUGH 1020, TYPE B, Fu=65 KSI. HEADED STUDS SHALL BE AS SHOWN ON
PLANS AND DETAILS.
WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING
CODE - SHEET STEEL". FIELD WELDS SHALL BE WIRE BRUSHED AND PRIMED
PAINTED WITH ZINC RICH PAINT.
DECK OPENINGS MEASURING GREATER THAN 12" ON ANY SIDE SHALL HAVE
SUPPORTS ON ALL SIDES OF OPENING. SUPPORTS SHALL SPAN BETWEEN
ADJACENT BEAMS OR JOISTS ON TWO SIDES. UNLESS OTHERWISE NOTED OR
DETAILED ON THE DRAWINGS, USE 5x5x5/16" ANGLES FOR SPANS EXCEEDING 6'-0" AND 3x3x1/4" ANGLES FOR SPANS LESS THAN 6'-0". COORDINATE OPENING SIZES, LOCATIONS AND DETAILS WITH ARCHITECTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL DRAWINGS.
PERMANENT SUSPENDED LOADS SUCH AS SUSPENDED CEILINGS, LIGHT
FIXTURES, DUCTS, OR OTHER UTILITIES, SHALL NOT BE SUPPORTED BY STEEL
ROOF DECK.
DURING STEEL DECK ERECTION AND ROOFING OPERATIONS DISTRIBUTE
CONSTRUCTION LOADS TO PREVENT DAMAGE TO DECK. CONCENTRATED
CONSTRUCTION LOADS OF 200 POUNDS OR LESS DISTRIBUTED OVER A 1'-0" WIDE
SECTION OF DECK SHALL NOT REQUIRE ANY FURTHER DISTRIBUTION. USE
WORKING PLATFORMS FOR CONCENTRATED CONSTRUCTION LOADS OF OVER
200 POUNDS, SUCH THAT THE RESULTING UNIFORM CONSTRUCTION LOAD ON
THE DECK DOES NOT EXCEED 50 PSF.
DURING POURING OF CONCRETE OVER FLOOR FORM DECKS TAKE CARE TO
AVOID EXCESSIVE CONCRETE HEAPING. POUR CONCRETE OVER BEAMS AND
SPREAD TO THE CENTER OF THE DECK.
PREPARE AND SUBMIT SHOP DRAWINGS FOR REVIEW SHOWING THE LAYOUT AND
TYPES OF DECK UNITS, ANCHORAGE DETAILS AND CONDITIONS REQUIRING
CLOSURE STRIPS, SUPPLEMENTARY FRAMING AND OTHER ACCESSORIES.
TOUCH-UP ALL SCARRED, ABRADED, AND RUST AREAS IN STEEL DECK WITH ZINC
RICH PAINT.
POST-INSTALLED ANCHOR NOTES:
POST-INSTALLED ADHESIVE ANCHORS SHALL BE CAPABLE OF WITHSTANDING
DESIGN LOADS INDICATED IN THE ADHESIVE ANCHOR CAPACITY SCHEDULE ON
ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON TECHNICAL DATA
PUBLISHED BY THE ANCHOR MANUFACTURER OR SUCH OTHER METHOD AS
APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. CONTRACTOR SHALL
PROVIDE CALCULATIONS DEMONSTRATING THAT THE CHOSEN ANCHOR IS
CAPABLE OF ACHIEVING THE PERFORMANCE VALUES INDICATED. PRODUCTS
SUBMITTED WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING
COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD
RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE
INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO
CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION
TEMPERATURE.
INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN
ANCHOR PACKAGING.
OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING A PROPERLY
TESTED AND APPROVED INSTALLATION METHOD.
THE CONTRACTOR SHALL ARRANGE A REPRESENTATIVE OF THE ANCHOR
MANUFACTURER TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL
ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD
MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S
PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE
COMMENCEMENT OF INSTALLING ANCHORS.
ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT
ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL
ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED
ON THE DRAWINGS.
EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT
WITH SPECIFIC ANCHOR LOCATIONS. UNLESS NOTED ON THE DRAWINGS THAT
THE BARS CAN BE CUT, THE CONTRACTOR SHALL REVIEW THE EXISTING
STRUCTURAL DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION OF
THE REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS, BY
GPR, X-RAY, CHIPPING OR OTHER MEANS.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
A.
1.
2.
3.
4.
5.
6.
7.
COMPONENTS AND CLADDING DESIGN PRESSURES (PSF)
ROOF
ZONE
TRIBUTARY AREA (SQ. FT.)
WALL
ZONE
10 50 250
TRIBUTARY AREA (SQ. FT.)
10 50 250
+34.8 -46.4
+34.8 -37.7
+31.2 -39.2
+31.2 -34.1
+27.6 -32.1
+27.6 -30.5
+16.0 -96.0
+16.0 -63.8
+14.0 -57.7
+14.0 -48.0
+13.0 -41.2
+13.0 -41.2
+16.0 -38.0 +14.0 -35.8 +13.0 -34.8
NOTES:
PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD OR AWAY
FROM THE SURFACES, RESPECTIVELY.
WIDTH OF COEFFICIENT PRESSURE ZONE, a = 10 FEET. SEE 'COMPONENT AND
1.
2.
CLADDING LEGEND' ON THIS SHEET FOR LOCATIONS.
MINIMUM STEEL COMPOSITE DECK PROPERTIES SHALL BE AS FOLLOWS:1.
DESIGN THICKNESS = 0.0358 IN.
Ip = 0.409 IN4 / FT Sp = 0.341 IN3/FT In = 0.406 IN3/FT Sn = 0..346 IN3/FT Fy = 50 KSI
A.
B.
C.
D.
E.
F.
C.
2 1 2
COMPONENT AND CLADDING LEGEND
TYPICAL UNIT PLAN TYPICAL SIDE WALL
5 4 5
10' (TYP.) 10' (TYP.)
ALL WIND PRESSURES ARE ULTIMATE LOADS. FOR SERVICE LOAD PRESSURES,3.
MULTIPLY THE ABOVE VALUES BY 0.6 PER ASCE 7-10.
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE
NOTES (THESE NOTES SHALL BE USED FOR ALL SPLICES UNLESS NOTED OTHERWISE ON DRAWINGS):
91"
101"
#10
#11
70"
78"
91"
101"
118"
131"
61"
67"
79"
87"
79"
87"
102"
114"
REGULAR
CLASS
f'c = 3,000 PSI
B
29"
22"
43"
72"
63"
36"
81"
A
#8
#9
#6
#7
55"
62"
33"
48"
#4
#5
#3
22"
28"
17"
Fy =
60 KSI
BAR
SIZE
TENSION BARS
BABABA
72"
81"
63"
43"
93"
105"
48"
54"
56"
81"
29"
42"
29"
36"
22"
19"38"
47" 24"
28" 15"
37"
62"
54"
70"
62"
70"
37"
54"
81"
91"
49"
71"
25"
19"
31"
25"
31"
19"
33"
41"
25"
REGULAR
CLASS
f'c = 4,000 PSI
TOP
CLASS
TOP
CLASS
39"
43"
30"
34"
23"
27"
15"
19"
12" f'c = ALL
COMPRESSION BARS
65"
73"
85"
94"
85"
94"
110"
122"
BABA
51"
58"
31"
45"
21"
26"
16"
40"
67"
59"
75"
67"
75"
40"
59"
87"
98"
52"
75"
27"
21"
34"
27"
34"
21"
36"
44"
26"
REGULAR
CLASS
f'c = 3,500 PSI
TOP
CLASS
TOP BARS ARE HORIZONTAL BARS, SPLICED SO THAT 12" OR MORE OF FRESH CONCRETE IS CAST IN THE MEMBER
CLASS A SPLICES MAY BE USED ONLY WHEN 50% OR LESS OF THE BARS ARE SPLICED WITHIN THE LAP SPLICE LENGTH.
CLASS B SPLICES SHALL BE USED FOR ALL SPLICES IN SLABS, BEAMS, JOISTS, WALLS, MOMENT RESISTING COLUMNS, THE BAR LAP SPLICE LENGTHS SHALL BE MULTIPLIED BY 1.5 WHEN EITHER OF THE FOLLOWING IS TRUE:
CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN ONE BAR DIAMETER, CLEAR COVER IS LESS THAN
ONE BAR DIAMETER AND STIRRUPS OR TIES ALONG THE LENGTH OF THE SPLICE ARE LESS THAN THE CODE MINIMUM.
CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN 2 BAR DIAMETERS AND CLEAR COVER IS LESS
THAN ONE BAR DIAMETER.
FOR ALL LIGHTWEIGHT CONCRETE, LAP LENGTHS SHALL BE MULTIPLIED BY 1.3.
TIES AND STIRRUPS SHALL NOT BE SPLICED UNLESS APPROVED BY THE ENGINEER OF RECORD. ROUND COLUMN
AND JAMB COLUMNS, UNLESS THEY MEET THE REQUIREMENTS OF NOTE #2 ABOVE.
BELOW THE REINFORCING BAR.
3.
B.
6.
A.
4.
5.
2.
1.
TIES MAY BE SPLICED USING CLASS A LAPS.
3” ROOF DECK MUST BE 20 GAGE PAINTED NA RIB DECK
SPANNING PERPENDICULAR TO SUPPORTS UNLESS OTHERWISE NOTED.
ATTACH DECK TO STRUCTURAL STEEL SUPPORTS WITH 5/8” DIAMETER
PUDDLE WELDS AT EVERY RIB, INCLUDING RIBS WHERE SIDELAPS OCCUR.
FASTEN ADJACENT DECK UNITS WITH #10 SELF-TAPPING HEX HEAD SCREWS
AT 1/4 POINTS BETWEEN SUPPORTS ALONG SIDELAPS AND FASTEN
EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8” DIAMETER PUDDLE
WELDS AT SAME SPACING AS SIDELAP FASTENERS.
B.
WIND PRESSURES SHOWN ARE FOR AREAS 'E', 'G', 'H' AND 'K'.4.
20' 20'
10'
LO
W
E N
D
H
IG
H E
N D
D. 1" FORM DECK SHALL BE 22 GAGE GALVANIZED DECK SPANNING
PERPENDICULAR TO SUPPORTS UNLESS OTHERWISE NOTED. ATTACH DECK
TO STEEL SUPPORTS WITH #12 SELF-TAPPING HEX HEAD SCREWS AT EVERY
RIB, INCLUDING RIBS WHERE SIDELAPS OCCUR.
THIS SHEET. DESIGN VALUES INDICATED ARE WITHOUT REDUCTION FACTORS.
GROUT NEW AND EXISTING CMU WALLS 12" ALL AROUND ANCHOR.8.
ROD DIA. /
REBAR SIZE
ADHESIVE ANCHOR INTO CMU
3/4"
3/4"
5/8"
TENSION
5 5/8" 1,700 #
8" 1,490 #
1,435 #
1,350 #
6 1/2" 1,895 # 1,350 #
5/8" 8" 2,515 # 1,905 #
EMBEDMENT
DEPTH
ALLOWABLE LOADS
SHEAR
ROD DIA. /
REBAR SIZE
ADHESIVE ANCHOR INTO CONCRETE
3/4"
5/8" 3 1/4" 1,350 # 13,110 #
4" 1,310 # 19,370 #
1/2" 3" 1,300 # 8,235 #
EMBEDMENT
DEPTH
ULTIMATE STRENGTH
TENSION
#5 4 1,350 # 27,900 #
#4 6" 1,300 # 18,000 #
7,865 #
11,625 #
4,940 #
SHEAR
16,740 #
10,800 #
STEELBOND
IN TENSION
NOTES:
CRACKED CONCRETE
ANCHOR BOND STRENGTH IN CONCRETE MUST BE BASED ON
1.
MAXIMUM SHORT-TERM TEMPERATURE = 160°F
MAXIMUM LONG-TERM TEMPERATURE = 100°F3.
PERIODIC INSPECTION4.
THE FOLLOWING CRITERIA:
2.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-002
S T
R U
C T
U R
A L
N O
T E
S
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
STRUCTURAL TESTING:
THE FOLLOWING MATERIALS SHALL BE TESTED ACCORDING TO IBC SECTION
1704. ANY ITEMS FOUND TO BE DEFICIENT SHALL BE CORRECTED AND RE-
TESTED AT NO ADDITIONAL COST TO THE OWNER.
EARTHWORK: THE IN-PLACE DRY DENSITY OF COMPACTED FILL SHALL BE TESTED
FOR COMPLIANCE WITH THE GEOTECHNICAL REPORT. SEE THE GEOTECHNICAL
REPORT AND SPECIFICATIONS FOR THE FREQUENCY OF TESTING.
CONCRETE STRENGTH VERIFICATION AND TESTING: ALL CONCRETE SHALL BE
TESTED TO VERIFY STRENGTH, SLUMP, UNIT WEIGHT, AIR CONTENT AND
TEMPERATURE. SEE THE SPECIFICATIONS FOR TESTING CRITERIA, FREQUENCY,
AND ACCEPTABILITY CRITERIA.
STRUCTURAL MASONRY STRENGTH VERIFICATION AND TESTING: MASONRY
STRENGTH, F'm SHALL BE VERIFIED USING THE 'UNIT STRENGTH METHOD' PER IBC
CHAPTER 2105 AND AS FOLLOWS:
PRIOR TO CONSTRUCTION THE MASONRY UNITS AND GROUT SHALL BE
TESTED FOR COMPRESSIVE STRENGTH.
CERTIFICATES OF COMPLIANCE WITH STRENGTH REQUIREMENTS OF THE
MASONRY UNITS AND GROUT SHALL BE SUBMITTED BY THE MASONRY AND
GROUT SUPPLIERS.
DURING CONSTRUCTION THE MASONRY UNITS AND GROUT SHALL BE
TESTED FOR EVERY 5,000 SQUARE FEET OF MASONRY CONSTRUCTED.
PROPORTIONS OF MATERIALS IN MORTAR AND GROUT DELIVERED TO THE
SITE SHALL BE VERIFIED.
STRUCTURAL STEEL: WELDED CONNECTIONS SHALL BE TESTED FOR
COMPLIANCE WITH THE SPECIFICATIONS, AWS D.1.1 AND THE CONTRACT
DOCUMENTS. MINIMUM TESTING SHALL INCLUDE THE FOLLOWING:
ALL COMPLETE PENETRATION GROOVE WELDS SHALL BE TESTED
ACCORDING TO METHODS DESCRIBED IN THE SPECIFICATIONS.
A MINIMUM OF 50% OF PARTIAL PENETRATION GROOVE WELDS SHALL BE
TESTED ACCORDING TO METHODS DESCRIBED IN THE SPECIFICATIONS.
BASE METALS THICKER THAN 1-1/2" THAT ARE SUBJECT TO THROUGH
THICKNESS WELD SHRINKAGE STRAINS SHALL BE ULTRASONICALLY
TESTED FOR DISCONTINUITIES. TESTING SHALL BE PERFORMED DIRECTLY
BEHIND SUCH WELDS AND THREE INCHES ABOVE AND BELOW THE WELD
AFTER JOINT COMPLETION.
ALL DEFICIENT WELDS SHALL BE CORRECTED AND RE-TESTED AT NO
ADDITIONAL COST TO THE OWNER.
POST-INSTALLED ANCHORS, INCLUDING BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS, AND LOW VELOCITY FASTENERS SHALL BE
TESTED ACCORDING TO THE RELEVANT ANCHOR CODE EVALUATION REPORTS.
SEE THE IBC AND OTHER CONSULTANTS' DRAWINGS FOR NON-STRUCTURAL
ITEMS REQUIRED TO BE TESTED.
1.
2.
3.
4.
5.
6.
7.
A.
B.
C.
D.
A.
B.
C.
D.
SPECIAL INSPECTIONS:
SPECIAL INSPECTIONS SHALL BE COMPLETED FOR THE FOLLOWING ELEMENTS
ACCORDING TO IBC SECTION 1704.
EARTHWORK SHALL BE SPECIAL INSPECTED AS FOLLOWS:
PRIOR TO PLACEMENT OF PREPARED FILL, QUALITY ASSURANCE AGENT
SHALL DETERMINE THE SITE HAS BEEN PREPARED ACCORDING TO THE
GEOTECHNICAL REPORT AND STONE IMPROVEMENT SPECIFICATIONS.
QUALITY ASSURANCE AGENT SHALL DETERMINE FILL MATERIAL AND LIFT
THICKNESSES COMPLY WITH GEOTECHNICAL REPORT
CONCRETE AND ELEMENTS EMBEDDED IN CONCRETE SHALL BE SPECIAL
INSPECTED PRIOR TO, AND DURING, PLACEMENT OF CONCRETE. SPECIAL
INSPECTIONS SHALL INCLUDE THE FOLLOWING:
PERIODIC INSPECTION:
REINFORCING STEEL SIZE AND PLACEMENT
VERIFY USE OF APPROVED MIX DESIGN
AFTER PLACEMENT TO ENSURE ADEQUATE CURING AND WEATHER
PROTECTION PROCEDURES
SURFACE PREPARATION AND DETAILS AT COLD JOINTS, INCLUDING
PLACEMENT OF KEYWAYS
INSPECTION OF CONCRETE FORMWORK, SHORING AND RESHORING
CONTINUOUS INSPECTION:
BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING
PLACEMENT OF CONCRETE
DURING PLACEMENT OF CONCRETE
STRUCTURAL MASONRY SHALL BE SPECIAL INSPECTED ACCORDING TO THE
FOLLOWING:
PERIODIC INSPECTION:
PROPORTIONS OF SITE-PREPARED MORTAR
CONSTRUCTION OF MORTAR JOINTS
SPECIFIED SIZE, LOCATION, GRADE AND TYPE OF REINFORCEMENT
SIZE AND LOCATION OF STRUCTURAL ELEMENTS
TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING DETAILS OF
ANCHORAGE OF MASONRY TO PRIMARY STRUCTURAL SYSTEM
CLEANLINESS OF GROUT SPACE
PROTECTION OF MASONRY DURING HOT AND COLD WEATHER
PLACEMENT.
CONTINUOUS INSPECTION:
PREPARATION OF ANY GROUT SPECIMENS, MORTAR SPECIMENS
AND/OR PRISMS
GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE COMPLIANCE
WITH CODE AND CONSTRUCTION DOCUMENT PROVISIONS.
STRUCTURAL STEEL FABRICATION AND ERECTION SHALL BE SPECIAL INSPECTED
AS FOLLOWS:
PERIODIC INSPECTION:
HIGH-STRENGTH BOLTS, NUTS AND WASHERS ACCORDING TO IBC
SECTION 1704.3.3
SINGLE-PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16"
FLOOR AND ROOF DECK WELDS
STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH
CONSTRUCTION DOCUMENTS INCLUDING MEMBER LOCATIONS,
CONNECTION DETAILS AND ANY OTHER BRACING AND STIFFENING
DETAILS
HEADED STUD WELDING, QUANTITY AND LOCATIONS
CONTINUOUS INSPECTION:
FILLET WELDS GREATER THAN 5/16" AND ALL MULTI-PASS WELDS
GROOVE WELDS, INCLUDING PARTIAL AND COMPLETE PENETRATION
WELDING OF PRIMARY MEMBERS OF MOMENT FRAMES AND THEIR
CONNECTIONS.
COLD-FORMED STEEL FRAMING (EXTERIOR CLADDING STUDS) SHALL BE SPECIAL
INSPECTED AS FOLLOWS:
PERIODIC INSPECTION:
SIZE, GRADE AND LAYOUT OF FRAMING MEMBERS
WELDING OPERATIONS
CONNECTION DETAILS SUCH AS SCREWING, BOLTING, ANCHORING,
BRACING AND HOLD DOWNS.
POST-INSTALLED ANCHORS, INCLUDING BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS, AND LOW VELOCITY FASTENERS SHALL BE
SPECIAL INSPECTED ACCORDING TO THE RELEVANT ANCHOR CODE EVALUATION
REPORTS.
CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING THE
INSTALLATION OF POST-INSTALLED ANCHORS. SPECIAL INSPECTOR
SHALL VERIFY THE FOLLOWING:
ANCHOR SIZE AND STEEL GRADE
HOLE DIAMETER, LOCATION AND TYPE OF DRILL BIT
COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS, INCLUDING
HOLE AND ANCHOR CLEANLINESS, AND ADHESIVE APPLICATION
ANCHOR EMBEDMENT DEPTH.
SEE THE IBC AND OTHER CONSULTANTS' DRAWINGS FOR NON-STRUCTURAL
ITEMS REQUIRED TO BE SPECIAL INSPECTED.
1.
2.
3.
4.
5.
6.
7.
8.
A.
B.
A.
B.
A.
B.
A.
B.
A.
A.
1.
2.
3.
4.
5.
1.
2.
1.
2.
3.
4.
5.
6.
7.
1.
2.
1.
2.
3.
4.
5.
1.
2.
3.
1.
2.
3.
1.
2.
3.
4.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-003
S T
R U
C T
U R
A L
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
STRUCTURAL ABBREVIATION LIST:
WITH
PLUS/MINUS
CENTERLINE
ON CENTER
ANCHOR BOLT
ARCHITECT or ARCHITECTURAL
BOTTOM
BAR DIAMETER
BUILDING
BEAM
BRACING
BRIDGING
CENTER OF GRAVITY
CAST IN PLACE
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
COORDINATE
DETAIL
DIAMETER
DRAWING
EACH FACE
EACH WAY
EACH
ELEVATION
ELECTRICAL
ELEVATOR or ELEVATION
EXISTING
EXPANSION
FACE OF
FIRST RISER
FINISH or FINISHED
FLOOR
FOOTING
HOLLOW CORE
HOOK
HORIZONTAL
JOIST BEARING ELEVATION
JOINT
KIPS
KIPS PER SQUARE FOOT
KIPS PER SQUARE INCH
LONG
LONG LEG HORIZONTAL
LONG LEG OUTSTANDING
MIDDLE OF SLAB
MIDDLE OF WALL
MANUFACTURER or
MATERIAL
MECHANICAL
METAL
PRECAST
PRE-STRESSED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PLUMBING
RADIUS
REINFORCED or REINFORCING
REQUIRED
SLAB ON GRADE
STEPPED FOOTING
SECTION
SHEET
STANDARD
STIRRUP
STEEL
STRUCTURAL
TOP
TOP OF STEEL
TEMPERATURE
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WORKING POINT
WELDED WIRE FABRIC
CMU
ELEV.
J.B.E.
K.S.F.
K.S.I.
MANUF.
PSF
PSI
REINF.
U.O.N.
VERT.
W.P.
W.W.F.
S.O.G.
S.F.
SECT.
SHT.
STD.
STIR.
STL.
STRUCT.
T.
T.O.S.
TEMP.
TYP.
M.O.S.
M.O.W.
MATL.
MECH.
MTL.
P.C.
P.S.
PLUMB.
R.
REQD.
FLR.
FTG.
H.C.
HK.
HORIZ.
JT.
K
LG.
LLH
LLO
DET.
DIA.
DWG.
E.F.
E.W.
EA.
EL.
ELEC.
EXIST.
EXP.
F.O.
F.R.
FIN.
B.
B.D.
BLDG.
BM.
BRCG.
BRDG.
C.G.
C.I.P.
CLR.
COL.
CONC.
CONT.
COORD.
w/ o/c
A.B.
ARCH.
MANUFACTURER'S
ACI
ASTM
AMERICAN CONCRETE INSTITUTE
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
CANT. CANTILEVER
Pc PIECE
SCHED. SCHEDULE
GALV.
GD.
GALVANIZED
GRADE
DWL. DOWEL
ENG. ENGINEER
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
BTWN. BETWEEN
SIM. SIMILAR
SL. SLOPE
MAX.
MIN.
MAXIMUM
MINIMUM
N.T.S.
OPP.
NOT TO SCALE
OPPOSITE
D.
DBL.
DIAG.
DEEP or DEPTH
DOUBLE
DIAGONAL
EMB. EMBED or EMBEDMENT
W. WIDE or WIDTH
STIFF. STIFFENER
REF. REFERENCE
PROJ. PROJECTION
EQ. EQUAL
SPA. SPACE
B.E.J. BUILDING EXPANSION JOINT
G.C. GENERAL CONTRACTOR
F.L. FULL LENGTH
ga GAGE
ADJ. ADJACENT
BRG. BEARING
REVISIONREV.
C.J.P. COMPLETE JOINT PENETRATION
LSH
LSV
LONG SIDE HORIZONTAL
LONG SIDE VERTICAL
EQUIV. EQUIVALENT
LONG LEG VERTICALLLV
SHORT LEG OUTSTANDINGSLO
POWDER ACTUATED FASTENERPAF
STEEL JOIST INSTITUTES.J.I.
PRE-ENGINEERED BUILDINGP.E.B.
S.D.I. STEEL DECK INSTITUTEE.O. EDGE OF
CONN. CONNECT or CONNECTION
P.T. PRESSURE TREATED
MASONRYMAS.
STRUCTURAL STEEL
ARCHITECTURALLY EXPOSEDAESS
SEISMIC EXPANSION JOINTS.E.J.
A.R. ANCHOR ROD
DECK ASSEMBLY
SLOPED INTEGRAL ROOFS.I.R.D.A.
POST-TENSIONEDP/T
CL
INSULATED CONCRETE FORMICF
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
A
FINISHED FIRST FLOOR
TOP OF FOOTING
SECOND FLOOR AND
LOW ROOF FRAMING
ROOF FRAMING
WALL REINFORCING SCHEDULE
WALL MARK
WALL COMPOSITION
B C D
#5 A
T
2" o/ c (V
E R
T
#5 A
T
6" o/ c E
A C
H F
A C
E
V E
R T
#5 A
T
2" o/ c (V
E R
T
#5 A
T
4" o/ c (V
E R
T
#5 A
T
8" o/ c (H
O R
IZ
8" CMU
(E A
C H
W Y
T H
E
E
TOP OF FOOTING
WALL MARK
WALL COMPOSITION
F G
#5 A
T
2" o/ c (V
E R
T
#5 A
T
2" o/ c (V
E R
T
#4 A
T
8" o/ c (V
E R
T
EXIST.
8"±
CMU
FINISHED FIRST FLOOR
SECOND FLOOR AND
LOW ROOF FRAMING
ROOF FRAMING
#5 A
T
8" o/ c E
A C
H F
A C
E
H O
R
IZ
8" CMU
EXPANSION
JOINT
8" ICF 12" ICF
#5 A
T
8" o/ c (H
O R
IZ
8" ICF
#5 A
T
8" o/ c (H
O R
IZ
#5 A
T
8" o/ c (H
O R
IZ
#5 A
T
8" o/ c (H
O R
IZ
BOND
BEAM
BOND
BEAM
8" CMU
BOND
BEAM
#4 A
T
8" o/ c (V
E R
T
N O
T E
F A
N D
G
EXIST.
8"±
CMU
H J
#6 A
T
"o /c
V
E R
T
10" CMU
N O
T E
G
WALL REINFORCING PLAN SCHEDULE NOTES:
A. FOR CONCRETE AND CONCRETE MASONRY NOTES SEE SHEET S-001.
B. FOR TYPICAL CONCRETE MASONRY VERTICAL WALL REINFORCING
DETAILS SEE SHEET S-504. FOR TYPICAL ICF WALL REINFORCING
DETAILS SEE SHEET S-505.
C. FOR PARTITION WALLS NOT INDICATED PROVIDE #4 AT 48"o/c.
D. UNLESS OTHERWISE NOTED, REINFORCING SHALL BE CENTERED IN
MIDDLE OF WALL.
E. SEE RELEVANT PLANS, SECTIONS, DETAILS, AND ELEVATIONS
THROUGHOUT THE DRAWINGS FOR ADDITIONAL VERTICAL WALL
REINFORCING REQUIREMENTS.
F. AT LOCATIONS INDICATED ON PLAN, WALL SHALL BE FULLY
GROUTED FULL HEIGHT OF THE WALL.
G. ADD NEW VERTICAL REINFORCEMENT TO EXISTING CMU WALL.
SEE SHEET S-511 FOR 'TYPICAL EXISITNG MASONRY VERTICAL
WALL REINFORCING DETAILS'.
H. REMOVE FACESHELLS AND REINFORCE WALLS FROM SIDE OF
WALL INDICATED BY THIS NOTE.
J. REMOVE FACESHELLS OF ENTIRE BLOCK AND REINFORCE
VERTICAL CELL PER 'AT EXPOSED TO VIEW CMU WALL DETAIL'
ON SHEET S-511.
K. REMOVE FACESHELLS AND REINFORCE VERTICAL CELL PER
'AT CONCEALED CMU WALL DETAILS' ON SHEET S-511.
L. REMOVE FACESHELLS OF ENTIRE BLOCK AND REINFORCE
ALL CELLS OF PILASTER TO REMAIN AFTER DEMOLITION WITH #
5 AT 8" ON-CENTER PER 'AT EXPOSED TO VIEW CMU
DETAIL' ON SHEET S-511.
M. REINFORCE 8" JAMB BETWEEN WINDOWS WITH 2 - #5 VERTICAL
FOR FULL HEIGHT OF WALL.
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
E
E
E
E
E
E
E
E E
E
E
B
E
B
B
E
F
B
F E
E
A
E
E
G
GH
H
H
G
G
G
G
H
G
H
G
G
G
G
G
H
G
G
G
G
J
J
G
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND K
G
NOTES H
AND JNOTES H
AND J
NOTES H
AND K
NOTES H
AND J
NOTES H
AND K
NOTES H
AND K
NOTES H
AND K
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
NOTES H
AND J
C
C
NOTE L
N O
T E
L
SEE RELEVANT
FOUNDATION SECTION
FOR REINFORCING
NOTE M
NOTE M
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-010
W A
L L
R E
IN
F
O R
C
IN
G P
L A
N
A R
E A
S A
B
C
A N
D D
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
1/16" = 1'-0"
WALL REINFORCING PLAN -
AREAS A, B, C AND D
(FOR PLAN NOTES SEE THIS SHEET)
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
E
E
A
A
D
A
A
C
C
C
C
A
C
C
A
A
A A
D
D
D
A A
A
A A A
A
C
A
A
A
A
C
C
C
C
A
C
C
A
C
C
C
E
A
A
A
A
A
A
AA
D
F
C
ABOVE
ELEVATOR
PIT WALLS
C C
C C
NOTE M
NOTE M
NOTE M
NOTE M
NOTE M
NOTE M
NOTE M
NOTE M
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-011
W A
L L
R E
IN
F
O R
C
IN
G P
L A
N
A R
E A
S E
F
G
H
J A
N D
K
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
1/16" = 1'-0"
WALL REINFORCING PLAN - AREAS E, F, G, H, J AND K
(FOR PLAN NOTES AND LEGEND SEE SHEET S-010)
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
N
M.3
L
9.8
9.8
J
G.3
H
M
D
D.7
F
E
6.4
L.4
K
E.7
5.24.5
B
A
5.9
G
5.3
A'
C
C.5
D.8
E.3
F.1
J.9
L.1
L.3
ED
EC
EB
EA
E1 E2 E3 E4
G.4
G.5
H.5
H.6
6.1
1.5
6.9 7.2 8.1
L.7
M.4
D.2
E.4
3.5 6.7
3.1 3.7
6.2
G.6
H.4
1.6
1.4
EA.8
EC.2
E0.1
L.2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-020
D
IM
E N
S
IO
N P
L A
N
O V
E R
A L
L
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
1" = 20'-0"
DIMENSION PLAN - OVERALL
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
5.24.5
BB
A
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
FOR CONTINUATION SEE SHEET S-022
5.3
A'
C
17'-11 3/8" 29'-9 3/8" 6'-5 5/8"
(TYP.)
F.O. BUILDING
(TYP. U.O.N.)
CL COLUMN
(TYP. U.O.N.)
'-8
/4
5"
F.O. EXIST. PRECAST
CONC. WALL
'-1
1"
F.O. EXIST.
PRECAST
CONC. WALL
TO REMAIN
'-5
/8
/8
'-2
/8
'-0
/8
70'-10 3/8"
F.O. ICF WALL
4 7/8"+/-
F.O. BUILDING
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-021
D
IM
E N
S
IO
N P
L A
N
A R
E A
A
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
1/8" = 1'-0"
DIMENSION PLAN - AREA A
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
DIMENSION PLAN KEYNOTES
NO. DESCRIPTION
501 FIELD VERIFY DIMENSIONS TO EXISTING STRUCTURE.
502 SEE THE ARCHITECTURAL AND CIVIL DRAWINGS FOR DIMENSIONS TO SITE
WALLS.
503 SEE THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS TO EXISTING WALLS
AND COLUMNS.
504 SEE THE ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN. SEE THE
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF MASONRY CONTROL JOINTS.
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
FOR CONTINUATION SEE SHEET S-021
FOR CONTINUATION SEE SHEET S-023
5.3
C
C.5
D.8
E.3
F.1
1.5
D.2
E.4
(TYP.)
18'-1 5/16"+/- 12'-7 11/16"+/-
F.O. EXIST. PRECAST
CONC. WALL
1' -1
/2
CL COLUMN
(TYP. U.O.N.)
CL COLUMN AND EXIST.
9"+/- PRECAST CONC.
WALL TO BE DEMOLISHED
F.O. BUILDINGF.O. EXIST. PRECAST
CONC. WALL
'-9
/2
F.O. EXIST. PRECAST
CONC. WALL
1.6
7 1/2"+/-
1/
4"
EXIST. 9"+/- PRECAST CONC.
WALL TO BE DEMOLISHED
1.4
3/
END OF EXIST. 8"+/-
CMU WALL TO REMAIN
CL COLUMN AND
EXIST. 8"+/- CMU WALL
TO BE DEMOLISHED
'-1
7/
8"
'-0
/8
'-8
/4
F.O. EXIST. PRECAST
CONC. WALL
18'-7 3/8"+/-
5"
F.O. EXIST. PRECAST
CONC. WALL
F.O. EXIST.
PRECAST
CONC. WALL
TO REMAIN
4 7/8"+/-
F.O. BUILDING
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-022
D
IM
E N
S
IO
N P
L A
N
A R
E A
B
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
1/8" = 1'-0"
DIMENSION PLAN - AREA B
(FOR PLAN NOTES S-021)
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
FOR CONTINUATION SEE SHEET S-022
FOR CONTINUATION SEE SHEET S-024
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
F.1
ED
EC
EB
EA
E1 E2 E3 E4
(TYP.)
1/
4"
1.4
CL COLUMN AND
EXIST. 8"+/- CMU WALL
TO BE DEMOLISHED
'-9
/8
'-0
'-0
21'-0"+/- 21'-0"+/- 10'-9 1/16"+/-
EA.8
EC.2
'-6
E0.1
8' -9
/8
10'-2 7/8"+/-
'-6
CL EXIST. COLUMN
AND F.O. WALL
CL EXIST. COLUMN
(TYP. U.O.N)
F.O. ICF
WALL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-023
D
IM
E N
S
IO
N P
L A
N
A R
E A
C
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
1/8" = 1'-0"
DIMENSION PLAN - AREA C
(FOR PLAN NOTES S-021)
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
FOR CONTINUATION SEE SHEET S-023
O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
L.1
L.3
ED
E1 E2 E3
3.53.1 3.7
'-0
'-4
/1 6"
'-0
'-4
/8
6'-10 1/2"+/- 11'-4" 52'-8" 11'-0" 13'-8" 101'-8" 17'-8"
'-4
F.O. EXIST.
CONC. WALL
F.O. BUILDING
(TYP. U.O.N.)
49'-1 1/8"
1 1/2"+/-F.O. BUILDING
L.2 4" 21'-2 1/16" 20'-5" 11'-8 1/8" 48'-11 3/16"
F.O. ICF
WALL
1' -0
/1
6"
31'-5 1/2"± 17'-1 1/8"± 14'-8 7/8"
CL COLUMN AND
PRECAST CONC.
WALL TO BE
REMOVED
'-0
'-4
F.O. ICF
WALL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-024
D
IM
E N
S
IO
N P
L A
N
A R
E A
D
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
1/8" = 1'-0"
DIMENSION PLAN - AREA D
(FOR PLAN NOTES S-021)
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
7 8
D
D.7
F
E
E.7
G
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
FOR CONTINUATION SEE SHEET S-026
'-0
92'-8"
'-9
/8
'-9
/8
33'-5" 23'-10" 35'-5"
1'-10 7/8"
12'-1 5/8"
2" B.E.J.
'-1
/8
'-8
'-4
F.O. BUILDING
(TYP. U.O.N.)
CL COLUMN
(TYP.)
'-1
/4
'-7
/8
8' -2
/8
'-7
/2
8' -7
'-4
/2
1'-5 5/8"
2" B.E.J.
10'-1"
10'-8"
1'-5 5/8"
1'-5 5/8"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
P N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-025
D
IM
E N
S
IO
N P
L A
N
A R
E A
E
F O
R T
C A
M P
B E
L L
K
Y L
O U
IS
V
IL
L
E D
IS
T
R
IC
T
W A
L L E
R T
O D
D A
N D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E
V
IR
G
IN
IA
B
E A
C H
V
A
E H
I
S T
A F
F
J C
S /D
W S
M
A R
C H
A M
-3
-C W
T S
P R
O J E
C T
N O
RTA SUBMITTAL
F O
R T
C A
M P
B E
L L
M
ID
D L
E S
C H
O O
L
A M
KEY PLAN
NOT TO SCALE
A
B
C
D
E
F
G
H
J
K
1/8" = 1'-0"
DIMENSION PLAN - AREA E
(FOR PLAN NOTES S-021)
ARIMS: 200A Disposition: Maintain for 15yrs after construction
W
2Q R
R
-0
7 8
H
6.4
K
5.9
G
FOR CONTINUATION SEE SHEET S-025
FOR CONTINUATION SEE SHEET S-027
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0
F O
R C
O N
T
IN
U A
T
IO
N S
E E
S H
E E
T S
-0 29G.4
G.5
H.5
H.6
6.1 6.9 8.16.76.2
G.6
H.4
5'-11 3/4" 4'-2 15/16" 19'-0 1/8" 31'-9 1/16" 1'-3 5/8" 2'-8"
23'-10" 5'-0 11/16"
'-0
'-1 0"
1'-5 1/4"
2" B.E.J.
6'-10 3/16" 10'-8 11/16"
104'-4"
'-3
/4
1'-5 5/8"
3'-11 5/8"
3'-4"
'-3
/4
'-7
/8
1'-5 5/8"
CL COLUMN (TYP.)
This is the start of the file's text. The full file is on GovTribe.