W912QR20R0044_Plans-0002.pdf
PDF 10 MB Posted
- Solicitation number
- W912QR20R0044
About this file
This document outlines a request for proposal for the construction of an Aeromedical Evacuation Squadron Training/Administration Building at Joint Base Andrews in Maryland. Key details include:
-
The project involves construction of a 17,567 square foot masonry and steel facility to house administrative functions, classrooms, training rooms, an auditorium and support spaces. Supporting site work and utilities are also required.
-
Proposals are due under a best value tradeoff evaluation process, with technical factors considered approximately equal to price. Submissions should include past performance, management and price/financial information.
-
The contract is firm-fixed price for an estimated $10-25 million. The North American Industry Classification System code is 236220.
-
The solicitation is anticipated for release on May 26, 2020 through the System for Award Management website. Proposals are due 540 calendar days from notice to proceed. The contracting agency is the Department of the Army Corps of Engineers Louisville District.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INV =261.67
PLAYGROUND AREA
LOUISIANA AVE.
P A
T R
IC
K A
V E
STEAM PIT
ASSUMED
STEAM PIT
ASSUMED
INV = 247.22
INV = 247.32
INV = 247.32
INV = 247.50
INV = 259.23
INV = 261.83
5 INV = 267.91
INV = 268.18
INV = 269.56
INV = 270.79
INV = 271.14
INV = 271.96
INV = 271.97
INV = 272.18
INV = 272.19
INV = 272.79
INV = 272.80
INV = 272.80
INV = 272.97
INV = 272.97
INV = 273.11
INV = 273.12
INV = 273.28
INV = 273.42
INV = 273.43
S D
INV = 273.48
INV = 273.67
RIM EL = 273.73
8"FLOWLINE
INV = 273.97
C
INV = 274.57
INV = 274.74
POLE
WOOD
RIM EL = 275.46
PP#_
TYPE: GUM
SIZE: 12
W
INV = 276.50
INV = 276.50
TYPE: GUM
SIZE: 12
PP#_
S
D
RIM EL = 276.62
W
RIM EL = 276.79
INV = 277.00
W
RIM EL = 277.32
ID: DS1801
SQUARE GRATE
W
W
RIM EL = 278.03
W
RIM EL = 278.20
W
RIM EL = 278.63
W
RIM EL = 279.00
W
WW
W
RIM EL = 279.49
LIGHT POLE
ALUMINUM
W
W
AIR CONDITIONER
W
W
BOTTOM= 262.58'
AIR CONDITIONER
W
W
FFE=281.47
TYPE: OAK
SIZE: 14"
= 277.63
RIM EL
RIM EL = 278.46
INVERT IN CENTER
C
S
E
E
E
E
E
E
D
D
E
E
W
CB
D
CB
S
CI
CB
CB
W
CB
CC
CB
G
CB
CB
E
E E
E E
G
CI
26.25'
23.33'
.1
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L A
C E
L O
U
IS
V
IL
L E
K E
N T
U C
K Y
J B A
N D
R E
W S
M D
A E
R O
M E
D
IC
A L E
V A
C U
A T
IO
N S
Q U
A D
R O
N
T R
A
IN
IN
G A
N D A
D M
IN
IS
T R
A T
IO
N F
A C
IL
IT
Y
P N A
J X
F F
Y P
CERTIFIED FINAL
J U
N E
GENERAL SHEET NOTES
LEGEND
ITEM REMOVAL AS NOTED
LINEAR REMOVAL AS NOTED
SHEET KEYNOTES
AREAS TO BE REMOVED AS NOTED
PAVEMENT TO BE REMOVED
23. POTENTIAL ABANDONED UTILITY; REMOVE AS ENCOUNTERED
DETAIL D8, SHEET CU501 FOR REMOVAL LIMITS
22. REMOVE PAVEMENT FOR DEMOLITION OF UTILITIES; SEE
DETAIL D8, SHEET CU501 FOR REMOVAL LIMITS
21. REMOVE PAVEMENT FOR NEW UTILITY INSTALLATION; SEE
20. REMOVE ABANDONED STEAM PIT; ASSUME 14' DEPTH
19. REMOVE ABANDONED STEAM PIT; ASSUME 5' DEPTH
18. PROTECT EXISTING FACILITY SIGN
17. CUT AND CAP PIPE AT VALVE; SEE DETAIL C8 SHEET CU501
16. REMOVE GAS SERVICE LINE
15. PROTECT BURIED UTILITIES
14. REMOVE STORM PIPE
13. REMOVE CATCH BASIN
12. PROTECT MANHOLE
11. REMOVE ABANDONED STEAM MANHOLE
10. REMOVE GAS METER
9. REMOVE UTILITY POLE
8. REMOVE LIGHT POLE
7. REMOVE AIR CONDITIONER AND BRICK SCREEN WALL
6. REMOVE CURB AND GUTTER
5. REMOVE SIDEWALK TO SUBGRADE
4. REMOVE ASPHALT PAVEMENT SECTION TO SUBGRADE
3. REMOVE TREE; SEE SPECIFICATION SECTION 31 11 00
LOCATION TO PROVIDE A CLEAN TIE-IN.
2. SAWCUT EXISTING ASPHALT ALONG NEW ENTRANCE
ASSOCIATED FEATURES
1. REMOVE BUILDING, STAIRS, LOADING DOCK AND ALL
CONSTRUCTION
SPECIFICATION SECTION 02 83 13.00 06 LEAD IN
LEAD IN CONSTRUCTION STANDARD 29 CFR1926.62. SEE
AND MUST BE HANDLED IN ACCORDANCE WITH THE OSHA
7. ALL PAINTED SURFACES ARE ASSUMED TO CONTAIN LEAD
SECTION 02 82 00 ASBESTOS REMEDIATION.
TO BE HANDLED IN ACCORDANCE WITH SPECIFICATION
6. ALL ASBESTOS CONTAINING MATERIALS (ACM) ARE REQUIRED
CAP VOID USING QUICK SETTING HYDRAULIC CEMENT.
5. WHERE PIPES ARE REMOVED FROM EXISTING MANHOLES,
31 00 00.00 06 EARTHWORK.
PLACED AND COMPACTED FILL PER SPECIFICATION
EDGE SHALL BE REMOVED AND REPLACED WITH PROPERLY
PLANNED BUILDING AND EXTENDING 5' BEYOND THE BUILDING
4. THE UPPER 5' OF EXISTING FILL DIRECTLY BELOW THE
CONSTRUCTION.
AND RELOCATION WILL BE COMPLETED BY OTHERS PRIOR TO
3. REQUIRED SANITARY SEWER AND WATER LINE DEMOLITION
AND CONSTRUCTION.
FOR DEMOLITION SHALL BE PROTECTED DURING DEMOLITION
2. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED
UTILITIES.
SHALL BE RESPONSIBLE TO VERIFY ALL EXISTING
1. PRIOR TO ANY AND ALL CONSTRUCTION, CONTRACTOR
LRL_Screen.dscriptLRL_pdf.pltcfg12:24:34 PM 7/22/2020
...\Military\481544\CAD_BIM\CAD_BIM\03_Sheets\481544_CD101.dgn
A E
C S h e e tS e e d .d g n
NORTH
PLAN
CD101
20' 40'0
D E
M O
L
IT
IO
N P
L A
N
A1
DEMOLITION PLAN
B
D O
R S
C H
T S
M
IT
H
B S
A Y
L O
R
M
B A
R R
Y
1" = 20'
A M
D T M
O D
IF
IE
D G
E N
E R
A L N
O T
E S A
N D K
E Y
N O
T E
S -2
-2
W
2Q R
R
_P la ns -0
PLAYGROUND AREA
LOUISIANA AVE.
P A
T R
IC
K A
V E
PP#_
PP#_
W
W
.5
39.22'14.25'
6'
12'5'12'
.5
9'
.5
.5
9'
15.67'
24.93'
.7
18.93'
.5
25.34'
.7
49.6'
.3
.3
58.73'
61.05'
.2
10'
6'
6'
25'
3.27' 2.27'
9.45' 10.41'
R
R
4'
R
R
20'
R
R
5' R
5'
R
46'
R
R
2'
R
5' R
R
R
R
15' R15
R
.6
16.25'
13.67'
31.81'
25'
28.97'
.8
30.26'
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L A
C E
L O
U
IS
V
IL
L E
K E
N T
U C
K Y
J B A
N D
R E
W S
M D
A E
R O
M E
D
IC
A L E
V A
C U
A T
IO
N S
Q U
A D
R O
N
T R
A
IN
IN
G A
N D A
D M
IN
IS
T R
A T
IO
N F
A C
IL
IT
Y
P N A
J X
F F
Y P
CERTIFIED FINAL
J U
N E
4 4
6 6
3 3
1+00
Sta. 0+00.00
POB
Sta. 1+78.32
POE
S ta .0
P O
B
S ta .3
P O
E
CL POV LOT
Sta. 0+00.00
POB
Sta. 0+83.61
POE
ENTRANCE
CL WEST
TYP.
TYP.
TYP.
TYP.
TYP.
NEW BUILDING 3744
BUILDING 3745
LOOP
CL ACCESS
SUBMERGED GRAVEL
WETLAND; SEE CG101
11111111
A
B
C
D
F
G
H
I J
K
L
M
NO
P
Q R
S
T
U
V
W
X
Y
Z
1A
1B
1C
1D
1E
1F1G
1H
1I
1J
1K
1L 1M 1N
1O
1P
1Q
1R 1S
1T1U
E
1V
1W
1X 1Y
1Z
2A 2B
2C
2D 2E
2F
2G
2H
2I
2J
2K
2L 2M
GENERAL SHEET NOTES
SHEET KEYNOTES
LEGEND
UNLESS OTHERWISE NOTED.
3. SPOT COORDINATES ARE TO THE EDGE OF PAVEMENT
NOTED.
ARE TO THE EDGE OF PAVEMENT UNLESS OTHERWISE
2. ALL DIMENSIONS ARE IN US SURVEY FEET. DIMENSIONS
1. SEE VA101 FOR CONTRACTOR WORK LIMITS
SIGN; USE AS NOTED
ASPHALT PAVEMENT
CONCRETE PAVEMENT; USE AS NOTED
REQUIREMENTS
SHEET CU501 FOR PAVING LIMITS AND BACKFILLING
EXISTING; SEE SHEET SHEET CD101 AND DETAIL D8
16. REPLACE PAVEMENT. MATCH SECTION AND GRADE OF
15. OXYGEN STORAGE AREA; SEE ARCHITECTURAL PLANS
14. CONCRETE PAVEMENT; SEE STRUCTURAL DRAWINGS
13. DUMPSTER PAD; SEE DETAIL A2, SHEET CS502
DETAIL C4, SHEET CS501
12. PARALLEL HANDICAP ACCESSIBLE RAMP; SEE
11. BOLLARD; SEE DETAIL C9, SHEET CS502
A5, SHEET CS502
10. REINFORCED CONCRETE PAD; SEE DETAIL
F4, SHEET CS502
9. TIE-IN TO EXISTING PAVEMENT; SEE DETAIL
F6, SHEET CS502
8. NO PARKING AREA STRIPING; SEE DETAIL
SHEET CS502
7. PARKING SPACE STRIPING; SEE DETAIL F9,
SHEET CS501
6. RESERVED ADA PARKING SIGN; SEE DETAIL A2,
A7, SHEET CS501
5. HANDICAP ACCESSIBLE PARKING; SEE DETAIL
SEE DETAIL B2, SHEET CS502
4. PLAIN CONCRETE SIDEWALK, WIDTH AS SHOWN
RAMP; SEE DETAIL A4, SHEET CS501
3. PERPENDICULAR HANDICAP ACCESSIBLE
2. CURB AND GUTTER; SEE DETAIL B7, SHEET CS502
1. ASPHALT PAVEMENT; SEE DETAIL A8, SHEET CS502
LRL_Screen.dscriptLRL_pdf.pltcfg12:24:46 PM 7/22/2020
...\Military\481544\CAD_BIM\CAD_BIM\03_Sheets\481544_CS101.dgn
C S h e e tS e e d .d
CS101
IT
E P
L
N
A1 20' 40'0
NORTH
PLAN
SITE PLAN
B
D O
R S
C H
T S
M
IT
H
B S
A Y
L O
R
M
B A
R R
Y
1" = 20'
SITE COORDINATES
POINT NORTHING EASTING POINT NORTHING EASTING POINT NORTHING EASTING
-2
-2
A M
D T R
E O
M O
V E
D D
U M
P S
T E
R E
N C
L O
S U
R E
1 1
W
2Q R
R
_P la ns -0
VARIES
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L A
C E
L O
U
IS
V
IL
L E
K E
N T
U C
K Y
J B A
N D
R E
W S
M D
A E
R O
M E
D
IC
A L E
V A
C U
A T
IO
N S
Q U
A D
R O
N
T R
A
IN
IN
G A
N D A
D M
IN
IS
T R
A T
IO
N F
A C
IL
IT
Y
P N A
J X
F F
Y P
CERTIFIED FINAL
J U
N E
PLAN
F L
O W
BLDG
FROM
SECTION 1
NOTES:
FINISHED GRADE
BUILDING WALL
FOOTING
TRANSITIONAL COUPLING
MANUFACTURER'S STANDARD
CLEANOUT
FINISHED GRADE
OR APPROVED EQUAL)
FRAME (NEENAH R-1974-A
CAST IRON COVER AND
CONCRETE BASE
6" THICK (MIN.)
6" 45° PVC BEND
12" X 6" 45° PVC WYE
4" DIA. PVC PIPE
4" X 6" PVC ENLARGER
2 EACH 6" 45° PVC ELBOWS
6" 45° PVC BEND
PVC WYE
12" X 6" 45°
6" 45° PVC BEND
ROOF DRAIN PIPE
6" DIA. PVC
PVC WYE
12" X 6" 45°
PIPE
STORM DRAIN
12" DIA. PVC
AS PIPE SERVED
TO BE SAME SIZE
DIA. PVC PIPE
(2) 45° PVC BENDS
DRAIN LINES AS INDICATED.
STORM DRAIN LINES AND AT EACH 90 DEGREE TURN IN STORM
1. STORM DRAIN CLEANOUTS SHALL BE INSTALLED AT THE END OF
0.6% MIN.
A6
ROOF DRAIN LEADER
NTS
DOWNSPOUT
CAST IRON DOWNSPOUT SHOE
1 2 4 5 67893 10
NTS
E6
ROOF DRAIN CLEANOUT
STORM DRAIN PIPE
12" DIA. SCH. 80 PVC
ROOF DRAIN PIPE
6" DIA. SCH. 80 PVC
STORM DRAIN PIPE
12" DIA. SCH. 80 PVC
ROOF DRAIN PIPE
6" DIA. SCH. 80 PVC
PLAN
NTS
A3
MARYLAND TYPE G ENDWALL
LRL_Screen.dscriptLRL_pdf.pltcfg2:44:48 PM 7/23/2020
...\Military\481544\CAD_BIM\CAD_BIM\03_Sheets\481544_CG501.dgn
C S h e e tS e e d .d
CG501
R
A
IN
A G
E D
E T
A
IL
S
B
D O
R S
C H
T S
M
IT
H
B S
A Y
L O
R
M
B A
R R
Y
A M
D T M
O D
IF
IE
D D
E T
A
IL
-2
-2
W
2Q R
R
_P la ns -0
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L A
C E
L O
U
IS
V
IL
L E
K E
N T
U C
K Y
J B A
N D
R E
W S
M D
A E
R O
M E
D
IC
A L E
V A
C U
A T
IO
N S
Q U
A D
R O
N
T R
A
IN
IN
G A
N D A
D M
IN
IS
T R
A T
IO
N F
A C
IL
IT
Y
P N A
J X
F F
Y P
CERTIFIED FINAL
J U
N E
6" PIPE
TO SANITARY
SEWER
INCREASER
FINISHED
PAVEMENT
12" 12"
2'-0"x2'-0"
CONCRETE PAD
4" THICK
BUILDING WASTE
PVC PIPE
(2'-0" SECTION)
6" PVC
4" PVC
4" PVC
(1/16 BEND)
IRON BODY
FERRULE
WITH PVC
SCREW PLUG
PVC BRANCH
PIPE
MANHOLE
NTS
A8
CLEANOUT DETAIL
NTS
A5
MANHOLE CONNECTION
1 2 4 5 67893 10
NTS
C8
UTILITY PIPE CAPPING
NTS
D8
UTILITY TRENCH
NOTES:
1. ALLOWS FOR CHANGE OF DIRECTION
AND CHANGE OF DEPTH AT CLEANOUT.
2. CLEANOUT LOCATED A MINIMUM OF 3'-0"
FROM THE BUILDING.
NTS
B5
SERVICE LINE MANHOLE CONNECTION
PIPE CONNECTIONS TO BE SEALED
WITH NON-SHRINK GROUT TO MAKE
A WATERTIGHT CONNECTION
LRL_Screen.dscriptLRL_pdf.pltcfg12:24:53 PM 7/22/2020
...\Military\481544\CAD_BIM\CAD_BIM\03_Sheets\481544_CU501.dgn
C S h e e tS e e d .d
CU501
U T
IL
IT
Y D
E T
A
IL
S
B
D O
R S
C H
T S
M
IT
H
B S
A Y
L O
R
M
B A
R R
Y
-2
-2
M T C
H A
N G
E D D
E A
T
IL
A
N D N
O T
E
W
2Q R
R
_P la ns -0
I NFO RM ATIO N
S TR EET
S TR EET
STO P
STOP
STOP
SPEED
LOUISIANA AVE.
'-0
40' - 0" 40' - 0" 40' - 0"
SIZE: 1.5" DIAMETER
TYPE: CERCIS CANADENSIS-
EASTERN REDBUD
SIZE: 12" DIAMETER
TYPE: GUM
SIZE: 14" DIAMETER
TYPE: OAK
SIZE: 1.75" DIAMETER
TYPE: TILIA CORDATA -
LITTLELEAF LINDEN
SIZE: 1.75" DIAMETER
TYPE: TILIA CORDATA -
LITTLELEAF LINDEN
SIZE: 2" DIAMETER
TYPE: GLEDITISA TRIACANTHOS
VAR INERMIS - THORNLESS
HONEYLOCUST
LANDSCAPE LEGEND
EXISTING TREE TO REMAIN
EXISTING TREE TO BE DEMOLISHED
NEW TREE TO BE PLANTED
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
7/24/2020 9:46:18 AM
C:\Users\h2eddrah\Documents\481544_Revit2018_ARCH_SITE_AES_h2eddrah.rvt
L-110
AES
C O
M
PO
SI
TE
L
AN
D
SC
AP
E
PL
AN
M . B
AR
R
Y
R . H
O O
E
J.
S
C H
EN
KE
N
FE
LD
ER
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
FI
LE
N U
M
BE
R
1" = 20'-0"1 LANDSCAPE PLAN - COMPREHENSIVE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
N D
J U
L
W
2Q R
R
_P la ns -0
GENERAL NOTES
1. GENERAL NOTES SHALL APPLY UNLESS NOTED OTHERWISE IN THE CONTRACT
DOCUMENTS, INCLUDING PLANS, DETAILS, OR SPECIFICATIONS. USE TYPICAL
DETAILS WHERE APPLICABLE. SEE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
2. USE THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER DISCIPLINES.
COORDINATE THE WORK OF OTHER TRADES INCLUDING, BUT NOT LIMITED TO, THE
REQUIREMENTS FOR SLEEVES, INSERTS, HOLES, HANGERS, AND ANCHORS.
3. DO NOT SCALE THE DRAWINGS.
4. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO CONSTRUCTION. REPORT
DISCREPANCIES IN DIMENSIONS BETWEEN DIFFERENT DRAWINGS TO THE
CONTRACTING OFFICER PRIOR TO BEGINNING WORK IN AREAS THAT WILL BE
AFFECTED.
5. DURING THE BIDDING PHASE, THE CONTRACTOR SHALL SUBMIT A REQUEST FOR
INTERPRETATIONS OF CONFLICTS OR DISCREPANCIES. IF NO REQUEST IS MADE,
ALL PROVISIONS WILL BE ASSUMED TO BE INCLUDED IN THE BID. THE CONTRACTING
OFFICER SHALL DETERMINE WHICH PROVISION GOVERNS AND THE CONTRACTOR
SHALL PERFORM THE WORK AT NO ADDITIONAL COST TO THE GOVERNMENT.
6. NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES ON THE STRUCTURAL
DRAWINGS OR BETWEEN THE STRUCTURAL DRAWINGS AND OTHER DRAWINGS
(ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, ETC.) PRIOR TO
PROCEEDING WITH CONSTRUCTION.
7. DETAILS NOT SPECIFICALLY INDICATED SHALL BE SIMILAR TO DETAILS SHOWN FOR
SIMILAR CONDITIONS.
8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE SAFETY OF PERSONS
AND PROPERTY DURING CONSTRUCTION.
9. SLABS ON GRADE ARE DESIGNED PER THE DESIGN CRITERIA LISTED ON THE
DRAWINGS. THE CONTRACTOR SHALL PROVIDE SIGNED AND STAMPED
CALCULATIONS FOR LOADS THAT OCCUR DURING CONSTRUCTION EXCEEDING THOSE
LISTED ON THE DRAWINGS. THE CONTRACTOR SHALL SUBMIT SIGNED AND STAMPED
CALCULATIONS FOR CONSTRUCTION LOADS PRIOR TO COMMENCEMENT OF WORK.
10. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS AND METHODS TO
CONSTRUCT THE STRUCTURE, INCLUDING, BUT NOT LIMITED TO, VERIFICATION OF
LOAD CAPACITY OF THE STRUCTURE, NEW OR EXISTING, TO SUPPORT CONSTRUCTION
ACTIVITIES, EQUIPMENT, ETC. AND LIMITING THE AMOUNT OF CONSTRUCTION LOAD
IMPOSED ON THE STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT EXCEED
THE DESIGN CAPACITY OF THE FRAMING AT THE TIME THE LOADS ARE IMPOSED.
DAMAGE TO THE STRUCTURE CAUSED BY CONSTRUCTION ACTIVITIES SHALL BE
CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
TEMPORARY CONSTRUCTION MATERIAL SHALL REMAIN THE PROPERTY OF THE
CONTRACTOR AFTER COMPLETION OF THE PROJECT.
11. THE STRUCTURE IS DESIGNED ONLY TO FUNCTION AS A UNIT UPON COMPLETION OF
CONSTRUCTION. THE STRUCTURE IS DEPENDENT UPON DIAPHRAGM ACTION OF THE
ROOF DECK AND THE DIAPHRAGM ATTACHMENT TO THE FRAMES FOR STABILITY
AND RESISTANCE TO WIND FORCES. PROVIDE ALL BRACING REQUIRED TO PROPERLY
CONSTRUCT THE BUILDING UNTIL THE STRUCTURE IS COMPLETE AND CAPABLE OF
PROVIDING LATERAL STABILITY.
12. REPRODUCTION OF CONTRACT DRAWINGS SHALL NOT BE USED AS SHOP DRAWINGS.
SHOP DRAWINGS SHALL BE CHECKED, APPROVED, AND STAMPED BY THE
CONTRACTOR PRIOR TO SUBMISSION.
13. NON-STRUCTURAL ELEMENTS OF THE BUILDING (ARCHITECTURAL FINISHES, MASONRY
VENEER AND ASSOCIATED TIES, INSULATION, SHEATHING, DUCTWORK, PIPING, ETC.)
ARE TYPICALLY NOT SHOWN ON THE STRUCTURAL DRAWINGS. WHERE NON-
STRUCTURAL ELEMENTS ARE SHOWN ON THE STRUCTURAL DRAWINGS, THEY ARE
SHOWN FOR REFERENCE AND DESIGN INTENT ONLY. NON-STRUCTURAL ELEMENTS
SHALL BE CONSTRUCTED AS SHOWN ON THE OTHER DISCIPLINE DRAWINGS.
14. ELEVATIONS SHOWN ON STRUCTURAL DRAWINGS ARE IDEALIZED. ELEVATIONS ARE
BASED ON DECK THICKNESS AND SLOPES SHOWN ON DRAWINGS.
15. WALL OPENINGS AND TERMINATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE
FOR REFERENCE ONLY. WALL TERMINATIONS AND OPENING JAMBS, HEADS, AND SILLS
SHALL BE CONSTRUCTED PER THE ARCHITECTURAL DRAWINGS.
16. DO NOT PENETRATE STRUCTURAL MEMBERS WITH PIPES, CONDUIT, OR OTHER NON-
STRUCTURAL COMPONENTS UNLESS APPROVED BY THE CONTRACTING OFFICER OR
NOTED OTHERWISE.
17. USE MOST RECENT VERSION OF REFERENCED AMERICAN SOCIETY FOR TESTING AND
MATERIALS (ASTM) STANDARD UNLESS NOTED OTHERWISE IN THE REFERENCED
UFC, IBC, OR SPECIFICATIONS.
DESIGN CRITERIA
1. IN ACCORDANCE WITH IBC 2015 AND ASCE 7-10 AS MODIFIED BY UFC 1-200-01 AND
UFC 3-301-01.
2. DEAD LOADS: ACTUAL MATERIAL WEIGHTS PLUS ALLOWANCES.
3. LIVE LOADS
ROOF 20 PSF
FLOOR 100 PSF
MECH STORAGE 125 PSF
NOTE: LIVE LOAD REDUCTION WAS NOT USED FOR THE DESIGN OF THIS STRUCTURE
4. SNOW LOADS
GROUND SNOW LOAD Pg = 25 PSF IMPORTANCE FACTOR Is = 1.0 SNOW EXPOSURE FACTOR Ce = 0.9
THERMAL FACTOR
MAIN BUILDING Ct = 1.1 CANOPIES Ct = 1.2
ROOF SLOPE FACTOR Cs = 1.0 FLAT-ROOF SNOW LOAD (Pf = 0.7CeCtIsPg ≥ I Pg)
MAIN BUILDING Pf = 20 PSF CANOPIES Pf = 20 PSF
SLOPED-ROOF SNOW LOAD (Ps = CsPf) MAIN BUILDING Ps = 20 PSF CANOPIES Ps = 20 PSF
UNBALANCED SNOW SEE SHEET S-004
5. WIND LOADS
ULTIMATE WIND SPEED Vult = 115 MPH NOMINAL DESIGN WIND SPEED Vall = 89 MPH
RISK CATEGORY CATEGORY = II
WIND EXPOSURE CATEGORY CATEGORY = C
GUST EFFECT FACTOR FACTOR = 0.85
INTERNAL PRESSURE COEFFICIENTS
MAIN BUILDING GCpi = ± 0.18 CANOPIES GCpi = ± 0
WIND COMPONENTS AND CLADDING SEE SHEET S-004
6. SEISMIC LOADS
LOCATION PRINCE GEORGE,
MARYLAND
RISK CATEGORY CATEGORY= II
MAPPED SHORT PERIOD RESPONSE ACCELERATION Ss = 0.117g MAPPED 1 SECOND PERIOD RESPONSE ACCELERATION S1 = 0.050g
SITE CLASS CLASS = E
DESIGN SHORT PERIOD SPECTRAL RESPONSE COEF. Sds = 0.195 DESIGN 1 SECOND PERIOD SPECTRAL RESPONSE COEF. Sd1 = 0.117
SEISMIC DESIGN CATEGORY CATEGORY = B
BASIC SEISMIC-FORCE-RESISTING-SYSTEM:
STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR
SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR R = 3.0
SEISMIC RESPONSE COEFFICIENT Cs = 0.065 DESIGN BASE SHEAR V = 55 kips
ANALYSIS PROCEDURE
EQUIVALENT LATERAL FORCE METHOD
7. ENVIRONMENTAL SEVERITY CLASSIFICATION C3
8. DIAPHRAGM DESIGN
ROOF FLEXIBLE
FOUNDATION NOTES
1. THE FOUNDATIONS ARE DESIGNED BASED ON RECOMMENDATIONS INCLUDED IN
THE GEOTECHNICAL INVESTIGATION REPORT PREPARED BY THE US ARMY CORPS
OF ENGINEERS, LOUISVILLE DISTRICT, DATED FEB 2020.
2. THE CONTRACTOR SHALL RETAIN A GEOTECHNICAL ENGINEER LICENSED IN THE
STATE OF MARYLAND TO PROVIDE OBSERVATION AND TESTING SERVICES DURING
THE GRADING AND FOUNDATION PHASE OF CONSTRUCTION PER THE EARTHWORK
SPECIFICATIONS. INSPECTING AND TESTING REPORTS SHALL BE SUBMITTED TO THE
GOVERNMENT FOR REVIEW.
3. ALL EXISTING GRADE BEAMS AND SHALLOW FOUNDATION SHALL BE REMOVED IN
THEIR ENTIRETY. THE UPPER 5 FEET OF SOIL DIRECTLY BELOW THE PLANNED
BUILDING AND EXTENDING 5 FEET BEYOND THE BUILDING EDGE SHALL BE REMOVED
AND REPLACED WITH CONTROLLED STRUCTURAL FILL PER 31 00 00.00 06
EARTHWORK SPECIFICATION. EXISTING DRILLED SHAFTS SHALL BE CUTOFF TO A
DEPTH OF 5 FEET BELOW THE FINISHED FLOOR ELEVATION IN A MANNER THAT DOES
NOT RESULT IN UNACCEPTABLE DISTURBANCE TO THE SURROUNDING SOILS PER
THE CONTRACTING OFFICER, UNLESS THE DISTURBED SOILS ARE RECOMPACTED
PER 31 00 00.00 06 EARTHWORK SPECIFICATION.
4. INTERIOR SLABS ON GRADE SHALL BE PLACED OVER A 15 MIL VAPOR BARRIER OVER
A 6" MINIMUM THICKNESS CAPILLARY BREAK AGGREGATE BLANKET.
5. DO NOT ALLOW AGGREGATE BLANKET BELOW FLOOR SLAB TO BECOME SATURATED
DURING CONSTRUCTION. PREVENT WATER INFILTRATION INTO SUBGRADE.
6. SURFACE RUNOFF SHALL BE DIRECTED AWAY FROM FOUNDATION EXCAVATIONS
AND IS NOT PERMITTED TO POND WITHIN THE BUILDING FOOTPRINT.
7. LOWER THE PERCHED GROUNDWATER BY AN ACCEPTABLE DEWATERING SYSTEM.
THE GROUNDWATER LEVEL SHALL BE MAINTAINED CONTINUOUSLY A MINIMUM OF
2'-0" BELOW THE EXCAVATION WHEN EXCAVATIONS APPROACH THE GROUND
WATER LEVEL.
8. PREPARE SUBGRADE FOR SLABS ON GRADE PER THE EARTHWORK
SPECIFICATIONS.
9. CONDUIT SHALL BE LOCATED BELOW THE BOTTOM OF SLABS ON GRADE UNO.
ENCASE UNDERSLAB CONDUIT WITH FLOWABLE FILL (LEAN CONCRETE) UP TO THE
BOTTOM OF SLAB ELEVATION.
10. COORDINATE UNDERGROUND UTILITIES PRIOR TO THE START OF FOUNDATION
EXCAVATIONS. COORDINATE WITH UTILITY COMPANIES FOR ANY SHUT-OFF
REQUIREMENTS OF ACTIVE LINES.
11. OPEN FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE
LICENSED GEOTECHNICAL ENGINEER RETAINED BY THE CONTRACTOR PRIOR TO
PLACING CONCRETE.
12. EARTH-FORMED FOOTINGS ARE NOT ALLOWED.
13. PLACE FOUNDATION CONCRETE ON THE SAME DAY OF THE FOUNDATION
EXCAVATIONS. LEAN CONCRETE (500 PSI) MUD MAT SHALL BE PLACED OVER THE
PREPARED BEARING MATERIALS IF EXCAVATION MUST REMAIN OPEN DURING
INCLEMENT WEATHER OR OVERNIGHT. PROTECT FOUNDATION EXCAVATIONS FROM
STANDING WATER AND COLLAPSE.
14. THE MINIMUM DEPTH TO THE BOTTOM OF EXTERIOR FOOTINGS SHALL BE 36 INCHES
BELOW FINISHED FLOOR.
15. DO NOT PLACE FOUNDATION CONCRETE ON FROZEN OR SATURATED SUBGRADE.
16. SEE ARCHITECTURAL AND CIVIL/SITE DRAWINGS FOR CONTOUR AND LAYOUT OF
SIDEWALKS AND PAVEMENT. SLOPE EXTERIOR CONCRETE AWAY FROM BUILDING
PER THE CIVIL/SITE DRAWINGS.
DRILLED SHAFT NOTES
1. ELEVATIONS NOTED ARE TO APPROXIMATE BOTTOM OF DRILLED SHAFT
FOUNDATIONS. DEPTHS ARE FOR BASE BID PURPOSES ONLY. ACTUAL DEPTH
BEARING MAY VARY BASED ON LOCAL SITE CONDITIONS.
2. FINAL BEARING ELEVATION SHALL BE ADJUSTED TO MEET THE FOLLOWING
CRITERIA:
A. STRATA AT BOTTOM OF DRILLED SHAFT SHALL HAVE A BEARING
CAPACITY OF 3,000 PSF. IF BEARING STRATA VARIES BY MORE THAN 2'-0"
FROM PLAN ELEVATION, NOTIFY CONTRACTING OFFICER PRIOR TO
PLACING CONCRETE.
B. DRILLED SHAFT DEPTHS SPECIFIED ON DRAWINGS S-102 AND S-103 ARE
FOR BIDDING PUROSES. DRILLED SHAFTS SHALL BE EXTENDED TO A
DEPTH REQUIRED TO ACHIEVE THE SPECIFIED BEARING CAPACITY.
BEARING CAPACITY SHALL BE VERIFIED BY THE CONTRACTORS
GEOTECHNICAL ENGINEER. IF REQUIRED DEPTH DEVIATES FROM THE
VALUES SPECIFIED ON DRAWINGS S-102 AND S-103 BY MORE THAN 30%
NOTIFY CONTRACTING OFFICER PRIOR TO PROCEEDING WITH
INSTALLATION. DRILLED SHAFTS SHALL BE PROPERLY SEATED INTO
NATURAL UNDISTURBED SANDS AND SO THAT SIDE WALLS ARE FREE
FROM SOIL INCLUSIONS OR VOIDS, AND VERIFIED BY THE CONTRACTOR'S
GEOTECHNICAL ENGINEER PER SPECIFICATION 31 63 29.
3. ALL DRILLED SHAFTS SHALL BE INSTALL PER THE CONTRACTORS APPROVED
DRILLED SHAFT INSTALLATION PLAN.
4. ALL DRILLED SHAFTS SHALL BE FILLED WITH 4,000 PSI CONCRETE (28 DAY
STRENGTH). NO CONCRETE SHALL BE PLACED UNTIL THE DRILLED SHAFT HAS
BEEN INSPECTED AND APPROVED. AN ACCURATE VOLUME CHECK OF
CONCRETE PLACED IN EACH DRILLED SHAFT SHALL BE MADE BY THE
CONTRACTOR AS A CHECK TO VERIFY THE FINAL DIMENSIONS OF THE DRILLED
SHAFT. CONCRETE SHALL BE PLACED THE SAME DAY AS THE FINAL CLEANOUT
OF THE EXCAVATION.
5. CENTERLINES OF ALL DRILLED SHAFTS SHALL BE CHECKED FOR CONFORMANCE
TO SPECIFICATION PRIOR TO PLACING CONCRETE. ANY DEVIATION FROM THE
ACCEPTABLE INSTALLATION TOLERANCES SHALL BE REPORTED TO THE
CONTRACTING OFFICER AND NO CONCRETE SHALL BE PLACED UNTIL
AUTHORIZED BY THE CONTRACTING OFFICER. ANY CORRECTIVE MEASURES
REQUIRED BECAUSE OF MISALIGNMENT BEYOND THE PERMISSIBLE TOLERANCE
IS THE RESPONSIBILITY OF THE CONTRACTOR.
6. THE LOCATION OF EXISTING SEWER AND UNDERGROUND UTILITIES SHALL BE
VERIFIED PRIOR TO THE DRILLING OF DRILLED SHAFTS. IF EXISTING UTILITIES ARE
TO REMAIN IN PLACE, PROVIDE PROTECTION DURING DRILLED SHAFT
OPERATIONS. IF NEW DRILLED SHAFTS AS SHOWN ON PLAN WILL ENCROACH
UPON THOSE EXISTING STRUCTURES, THE CONTRACTOR SHALL CONTACT THE
CONTRACTING OFFICER FOR DIRECTION PRIOR TO PLACING DRILLED SHAFTS.
7. LOCATION OF EXISTING FOUNDATIONS AS SHOWN ON THE DRAWINGS ARE
APPROXIMATE. FIELD VERIFY. SEE GEOTECHNICAL REPORT AND CIVIL DRAWINGS
FOR DEMOLITION AND ADDITIONAL DETAILS.
8. IF GROUND WATER IS ENCOUNTERED DURING DRILLED SHAFT CONSTRUCTION,
CASE AND DEWATER SHAFTS PRIOR TO INSPECTION AND CONCRETE
PLACEMENT, OR ALLOW THE WATER TO STABILIZE AND TREMIE CONCRETE IN-
PLACE MAINTAINING A MINIMUM OF 5 FEET OF HEAD ABOVE THE TREMIE BOTTOM
AND GROUDWATER ELEVATION.
9. ELEVATIONS SHOWN ON PLAN ARE APPROXIMATE BEARING ELEVATIONS (NOT
TOP OF ROCK) WITH THE DEPTH OF THE EMBEDMENT INCLUDED. ADEQUATE
BEARING MAY BE AT LOWER ELEVATIONS (AS DETERMINED BY THE
GEOTECHNICAL ENGINEER). THE CONTRACTOR WILL NOT BE COMPENSATED
FOR UNNECESSARY EXCAVATION OF ADEQUATE BEARING MATERIAL TO ACHIEVE
ELEVATIONS SHOWN ON THE PLAN. ADJUSTMENTS TO PAYMENT WILL BE MADE
FROM THE BASE BID LUMP SUM BASED ON UNIT PRICES. UNIT PRICES FOR
ADDITIVE AND DEDUCTIVE ADJUSTMENTS SHALL BE THE SAME.
STRUCTURAL CONCRETE
1. STRUCTURAL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
AMERICAN CONCRETE INSTITUTE (ACI) 2014 "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE" (ACI 318), 2014 "SPECIFICATIONS FOR STRUCTURAL
CONCRETE" (ACI 303), AND 2004 "ACI DETAILING MANUAL" (ACI SP-66).
2. CAST-IN-PLACE CONCRETE FOR SLAB ON GRADE AND FOUNDATION GRADE BEAMS
SHALL ATTAIN A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4,000 PSI.
CAST-IN-PLACE CONCRETE FOR DRILLED SHAFT FOUNDATIONS SHALL ATTAIN A
MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 4,000 PSI.
3. CONCRETE DENSITY SHALL BE NORMAL WEIGHT FOR FOUNDATIONS AND SLAB ON
GRADE (SOG).
4. CONCRETE REINFORCEMENT SHALL BE STEEL DEFORMED BARS CONFORMING TO
ASTM A615, GRADE 60, EXCEPT WHERE WELDING REINFORCEMENT IS INDICATED.
WELDED REINFORCEMENT SHALL CONFORM TO ASTM A706, GRADE 60.
5. SHOP FABRICATE BENDS AND HOOKS. DO NOT FIELD BEND.
6. PROVIDE SUPPORTS FOR REINFORCEMENT AS NEEDED. WELDED WIRE
REINFORCEMENT SHALL BE SUPPORTED AT 2'-0" ON CENTER, EACH DIRECTION
MINIMUM. PROVIDE PLASTIC, PLASTIC-COATED (NOT PLASTIC TIPPED), OR STAINLESS
STEEL CHAIRS FOR CONCRETE EXPOSED TO VIEW.
7. CONCRETE REINFORCEMENT FOR SLABS ON GRADE SHALL BE LOCATED IN THE
MIDDLE THIRD OF THE SLAB UNLESS NOTED OTHERWISE AND BE POSITIVELY AND
CONTINUOUSLY SUPPORTED. SUPPORT SHALL BE MAINTAINED PRIOR TO AND
DURING CONCRETE PLACEMENT.
8. CONCRETE REINFORCEMENT SHALL BE CONTINUOUS. SPLICES SHALL BE MADE BY
LAPPING WITH CLASS B LAPS PER ACI 318.
9. BEND HORIZONTAL WALL AND FOOTING AND GRADE BEAM REINFORCEMENT 1'-0"
AROUND CORNERS OR PROVIDE CORNER BARS WITH 2'-0" LAP.
10. MINIMUM CONCRETE COVER FOR REINFORCEMENT SHALL BE IN ACCORDANCE WITH
ACI 318 AND UFC 3-301-01:
A. CONCRETE CAST AGAINST EARTH
1. SLAB-ON-GRADE
W31 OR D31 WIRE, AND SMALLER 1.5"
2. OTHER 3"
B. CONCRETE EXPOSED TO EARTH OR WEATHER 3"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER
1. SLABS, JOISTS, AND WALLS
#11 BAR AND SMALLER 1"
2. BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES 2"
11. PROVIDE STANDARD HOOKS WITH 90 DEGREE BENDS AND EXTEND A MINIMUM OF 12
BAR DIAMETERS IN LENGTH. STIRRUPS, TIES, AND 180 & 135 DEGREE HOOKS SHALL
CONFORM TO ACI 318.
12. PROVIDE 1/2" THICK JOINT FILLER MATERIAL WHERE SLABS ON GRADE ABUT
CONCRETE, MASONRY, OR STEEL VERTICAL SURFACES.
13. EMBEDDED ITEMS SHALL BE PROPERLY PLACED, ACCURATELY POSITIONED AND
SECURELY MAINTAINED IN PLACE PRIOR TO AND DURING CONCRETE PLACEMENT.
14. SPREAD CONCRETE REINFORCEMENT AT SLEEVES, ANCHORS, RECESSES AND
OTHER EMBEDDED ITEMS WHERE BAR SPACING WILL NOT EXCEED 1.5 TIMES THE
NORMAL SPACING. DO NOT CUT REINFORCEMENT TO FACILITATE PLACEMENT OF
EMBEDDED ITEMS.
#3
1. FOR CLASS 'A' SPLICE (PERMITTED ONLY WHEN NOT MORE THAN HALF THE
BARS SPLICED & SPLICES STAGGERED BY THE DISTANCE OF SPLICE LENGTH),
USE SAME AS ' Ld' = TENSION DEVELOPMENT LENGTH TABLE.
2. TOP BARS ARE DEFINED AS ANY HORIZONTAL BAR WITH MORE THAN 12" OF
FRESH CONCRETE CAST BELOW THE SPLICED BARS.
3. INCREASE LAP LENGTHS AS FOLLOWS (INCREASES ARE ACCUMULATIVE):
A. BAR SPACING LESS THAN 2 BAR DIAMETERS +50%
B. LIGHTWEIGHT CONCRETE +35%
C. EPOXY-COATED TOP BARS +20%
D. EPOXY-COATED OTHER BARS +50%
(GRADE 60 UNCOATED BARS - NORMAL WEIGHT CONCRETE)
TENSION LAP SPLICES - CLASS B
BAR SIZE
#4
#5
#6
#7
#8
#9
#10
#11 f'c= 3,000 psi f'c= 4,000 psi f'c= 5,000 psi
1'-10" 1'-7" 1'-6" 1'-5"
2'-5" 2'-1" 2'-0" 1'-11"
3'-0" 2'-7" 2'-6" 2'-4"
3'-7" 3'-1" 2'-11" 2'-10"
5'-3" 4'-6" 4'-3" 4'-1"
6'-0" 5'-2" 4'-11" 4'-8"
6'-9" 5'-10" 5'-6" 5'-3"
7'-6" 6'-6" 6'-1" 5'-9"
8'-2" 7'-1" 6'-8" 6'-4"
15. PROVIDE 3/4" CHAMFER AT EXPOSED CONCRETE EDGES OR WHERE CHAMFER
INDICATED.
16. ALUMINUM SHALL NOT BE PLACED IN DIRECT CONTACT WITH CONCRETE. COAT
ALUMINUM WITH COATING CONFORMING TO ASTM D1187, ASPHALT-BASE
EMULSION, TO PREVENT ALUMINUM-CONCRETE REACTION AND ELECTROLYTIC
ACTION BETWEEN ALUMINUM AND STEEL.
17. PROVIDE FOUNDATION DOWELS FOR WALLS, PIERS, AND COLUMNS. MATCH SIZE
AND SPACING OF VERTICAL STEEL.
18. PRIOR TO PLACEMENT OF CONCRETE, SUBMIT JOINT LAYOUTS TO THE
CONTRACTING OFFICER FOR APPROVAL. CONSTRUCTION JOINTS SHALL BE
POSITIONED TO PREVENT CHANGE IN STRUCTURAL DESIGN REQUIREMENTS.
LOCATE CONSTRUCTION JOINTS IN CONCRETE FLOORS SO LESS THAN 10,000 SF
OF CONCRETE IS POURED IN A SINGLE POUR AND THE MAXIMUM LENGTH OF
POUR DOES NOT EXCEED 100'-0". RATIO OF LENGTH TO WIDTH OF PANELS SHALL
NOT EXCEED 1.5.
19. SEAL THE VAPOR BARRIER OR WATERPROOFING SYSTEM TO PIPES AND
CONDUITS AT ALL PENETRATIONS THROUGH FLOOR SLABS AND FOUNDATION
WALLS.
20. SEE ARCHITECTURAL DRAWINGS FOR TYPE AND LOCATION OF FLOOR FINISHES,
FLOOR DEPRESSIONS, AND CURBS.
21. SEE MECHANICAL, ELECTRICAL, PLUMBING, AND CIVIL DRAWINGS FOR ADDITIONAL
SLAB PENETRATIONS, INSERTS, AND EMBEDDED ITEMS.
22. EXPOSED CONCRETE SUBJECTED TO FREEZE/THAW SHALL HAVE CEMENT
CONTENT OF 6 SACKS PER YARD MINIMUM, WATER/CEMENT RATIO OF 0.40
MAXIMUM, AND ENTRAINED AIR OF 6% ± 1%.
23. LAP SPLICES:
A. LAP COMPRESSION SPLICES 30 BAR DIAMETERS OF LARGER BAR.
B. LAP TENSION SPLICES PER THE FOLLOWING TABLE AND MODIFY LENGTHS
AS NOTED:
f'c= 4,500 psi
STRUCTURAL STEEL
1. STRUCTURAL STEEL DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 2010 "SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS" (AISC 360) AND 2010 "CODE OF STANDARD
PRACTICE FOR STEEL BUILDINGS AND BRIDGES" (AISC 303).
2. MATERIALS AND SHAPES.
a. WIDE FLANGE SHAPES SHALL BE ASTM A992, GRADE 50.
b. MISCELLANEOUS SHAPES, CHANNELS, ANGLES, AND PLATES SHALL BE
ASTM A36.
c. STRUCTURAL STEEL TUBING SHALL BE ASTM A500, GRADE B.
d. WELDING ELECTRODES SHALL BE E70XX EXCEPT WHERE OTHER ELECTRODES
ARE REQUIRED FOR COMPATIBILITY WITH MATERIAL BEING WELDED.
e. ANCHOR RODS SHALL BE ASTM F1554 GR. 36.
f. HEADED STUD ANCHORS (HSA) SHALL BE ASTM A108.
3. STEEL CONNECTIONS SHALL BE BOLTED OR WELDED AS INDICATED.
a. BOLTED CONNECTIONS SHALL CONFORM WITH THE RESEARCH COUNCIL ON
STRUCTURAL CONNECTIONS (RCSC) "SPECIFICATION FOR STRUCTURAL JOINTS
USING HIGH-STRENGTH BOLTS."
b. USE ASTM A325-SC, CLASS A BOLTED CONNECTIONS WITH HARDENED WASHERS
FOR MOMENT CONNECTIONS AND TENSION-ONLY CONNECTIONS (HANGERS).
c. USE FULLY PRE-TENSIONED ASTM A325-N BOLTED CONNECTIONS WITH
HARDENED WASHERS FOR CONNECTIONS UNLESS NOTED OTHERWISE.
d. USE HARDENED WASHERS FOR OVERSIZED AND SHORT-SLOTTED HOLES. USE
5/16" THICK A36 PLATE WASHERS FOR LONG-SLOTTED HOLES.
e. USE 3/4" DIAMETER (ø) BOLTS.
f. USE STANDARD SIZE BOLT HOLES. SHORT SLOTS PERPENDICULAR TO LOAD
MAY BE USED FOR BEAM END SHEAR CONNECTIONS.
g. PROVIDE MINIMUM EDGE DISTANCE AND BOLT SPACING PER AISC 360.
h. BOLTED CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS.
i. STRUCTURAL STEEL WELDING SHALL CONFORM WITH THE AMERICAN WELDING
SOCIETY (AWS) 2010 STRUCTURAL WELDING CODE - STEEL (AWS D1.1).
j. WHERE WELD SIZE IS NOT SHOWN, USE MINIMUM WELD SIZE PER AISC 360 AND
AWS D1.1. WHERE WELD LENGTH IS NOT SHOWN, USE CONTINUOUS WELDS.
k. WELDING SHALL BE PERFORMED BY OPERATORS CERTIFIED BY AWS IN
PERFORMING THE TYPE OF WORK INDICATED.
l. COLUMN BASES & SPLICED ENDS SHALL BE MILLED OR SAW CUT TO PROVIDE
FULL BEARING.
m. USE CONNECTIONS PER TYPICAL DETAILS WHERE APPLICABLE.
n. DEVELOP ONE-HALF OF THE TOTAL UNIFORM LOAD CAPACITY OF THE BEAM
WHERE TYPICAL DETAILS ARE NOT PROVIDED.
o. CONTRACTOR SHALL DESIGN CONNECTIONS NOT DETAILED. USE STANDARD
SHEAR CONNECTIONS IN THE AISC STEEL CONSTRUCTION MANUAL WHERE
POSSIBLE.
p. ANGLE OR PLATE CONNECTOR LENGTH FOR BEAM END CONNECTIONS SHALL
BE LARGER THAN 1/2 OF THE T DISTANCE OF THE BEAM WEB.
4. DO NOT FIELD CUT OR MODIFY STRUCTURAL STEEL FOR WORK OF
OTHER TRADES WITHOUT PRIOR WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
5. WHERE CAMBER IS NOT INDICATED FOR BEAMS, ORIENT BEAMS SO
RESIDUAL MILL CAMBER IS UPWARDS.
6. GALVANIZING: HOT DIP GALVANIZE STEEL EXPOSED TO WEATHER.
GALVANIZE PER ASTM A-123 FOR ROLLED, PRESSED, OR FORGED
SHAPES AND PLATES, ASTM A-153 FOR HARDWARE ITEMS, AND ASTM
A-386 FOR ASSEMBLED STEEL PRODUCTS. RELIEF ANGLES AND SHELF
ANGLES FOR MASONRY SHALL BE GALVANIZED. BOLTS EXPOSED TO
WEATHER OR BOLTS FOR STEEL EXPOSED TO WEATHER SHALL BE
HOT DIP GALVANIZED.
7. SURFACE PREPARATION: SEE SPECIFICATIONS.
8. PRIME PAINTING: AFTER MATERIAL HAS BEEN PROPERLY CLEANED
AND TREATED, APPLY SHOP PRIME COAT, EXCEPT SURFACES
EMBEDDED INTO CONCRETE, RECEIVING FIELD WELDING, RECEIVING
SPRAY-APPLIED FIREPROOFING, OR FAYING SURFACES OF PLIES
WITH SLIP CRITICAL BOLTS. TOUCH-UP PRIMER AT SITE.
MINIMUM DRY FILM THICKNESS SHALL BE 1.5 MIL.
9. DECK EDGE SUPPORT STEEL SHALL BE CONTINUOUS. SPLICE
SUPPORT STEEL WITH PARTIAL PENETRATION SQUARE GROOVE
WELD (BUTT JOINT) WITH 3/16" EFFECTIVE THROAT ON ONE SIDE OF
EACH LEG, MINIMUM UNO. SEE DETAIL .
10. HANGING LOADS BY OTHER TRADES, SUCH AS STAIRS, PIPES, DUCT,
ETC., SHALL APPLY VERTICAL ONLY LOADS AND NOT APPLY TORQUE
OR HORIZONTAL LOADS TO THE STRUCTURAL STEEL. HANGING
LOADS SHALL BE CENTERED ON THE MEMBER SO THAT THE LOAD
PASSES THROUGH THE SHEAR CENTER OF THE STEEL.
/1 S-522
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
7/23/2020 10:42:45 AM
C:\Users\h2eddkmj\Documents\481544_Revit2018_S_AES_h2eddkmj.rvt
S-001
AES
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
J.
B
U
SH
K.
J
O H
N
SO
N
D . S
M
IT
H
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
19' - 2" ± 19' - 0" ± 19' - 2" ±
18' - 4" ± 17' - 9" ± 18' - 11" ± 18' - 4" ± 18' - 4" ±
1'
0"
1'
0"
1'
0"
19' - 2" ± 19' - 0" ± 19' - 2" ± 18' - 4" ± 18' - 4" ± 18' - 4" ± 18' - 4" ± 18' - 4" ±
8'
8"
18' - 0" ± 18' - 1" ± 18' - 11" ± 18' - 4" ± 18' - 4" ±
18' - 11" ± 18' - 4" ± 18' - 4" ±
0"
92' - 8" ±
1' - 0" ± 56' - 4" ± 1' - 0" ±
S-003
EXISTING REINF
CONC GRADE
BEAM
EXISTING CONC
DRILLED SHAFT
FOUNDATION
MAX EXISTING
CONC BELL
APPROXIMATE
OUTLINE OF NEW
BUILDING FOOTPRINT
1' - 0" ± 35' - 2" ±
1'
0"
1'
0"
0"
1'
0"
8'
0"
28' - 0" ± 1' - 0" ± 6' - 0" ± 1' - 0" ± 28' - 0" ± 1' - 0" ±
65' - 0" ±
4'
6"
EXISTING REINF
CONC SPREAD
FOOTING
29' - 0" ± 6' - 8" ± 28' - 4" ±
EXISTING CMU
STEM WALL AND
WALL FOOTING
EXISTING
ORIGINAL
EXISTING
ADDITION
7' - 0" ±
54' - 8" ± 1' - 0" ±10" ±
8"
1'
0"
8" ± 8"
FIRST FLOOR
0' - 0"
5'
0"
EXCAVATE AND DEMO EXISTING
FOUNDATIONS 5'-0"± BELOW FINISH
FLOOR AND EXTENDING 5'-0" BEYOND
THE PLANNED BUILDING EDGE AND
REPLACE WITH STRUCTURAL FILL
SEE GEOTECHNICAL REPORT
T/EX PILE
-4' - 6"
EXISTING CONC
DRILLED SHAFT
FOUNDATION
EXISTING CMU
STEM WALL AND
WALL FOOTING
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
N
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
AREA "A" AREA "B"
KEY PLAN
7/23/2020 10:43:07 AM
C:\Users\h2eddkmj\Documents\481544_Revit2018_S_AES_h2eddkmj.rvt
S-003
AES
D
EM
O
LI
TI
O
N P
LA
N
J.
B
U
SH
K.
J
O H
N
SO
N
D . S
M
IT
H
3/32" = 1'-0"1 DEMOLITION PLAN - FOR REFERENCE ONLY
3/16" = 1'-0"2 EAST ELEVATION - FOR REFERENCE ONLY
1. DIMENSIONS ARE OBTAINED FROM AS BUILTS AND
SHALL BE FIELD VERIFIED BY THE CONTRACTOR.
2. SEE CIVIL DRAWINGS FOR LOCATION OF PROPOSED
STRUCTURE IN REFERENCE TO EXISTING FOUNDATIONS.
3. ALL EXISTING GRADE BEAMS AND SHALLOW FOUNDATION
SHALL BE REMOVED IN THEIR ENTIRETY. THE UPPER 5
FEET OF SOIL DIRECTLY BELOW THE PLANNED BUILDING
AND EXTENDING 5 FEET BEYOND THE BUILDING EDGE
SHALL BE REMOVED AND REPLACED WITH CONTROLLED
STRUCTURAL FILL PER 31 00 00.00 06 EARTHWORK
SPECIFICATION. EXISTING DRILLED SHAFTS SHALL BE
CUTOFF TO A DEPTH OF 5 FEET BELOW THE FINISHED
FLOOR ELEVATION IN A MANNER THAT DOES NOT RESULT
IN UNACCEPTABLE DISTURBANCE TO THE SURROUNDING
SOILS PER THE CONTRACTING OFFICER, UNLESS THE
DISTURBED SOILS ARE RECOMPACTED PER 31 00 00.00 06
EARTHWORK SPECIFICATION.
DEMO NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
SYMMETRICAL
ABOUT DRAIN
FLOOR DRAIN - SEE
ARCH & MECH DWGS
UPSET DRAIN IF REQ
FOR FLOOR FINISH
MIN UNO
2' - 0" RADIUS x 1/2" DEEP
SLOPE OR PER PATTERN
SHOWN ON PLAN SHEETS
T
3/4"øx10" SMOOTH DOWEL
BAR @ 12" OC
LUBRICATE ONE END OR
SET FIRST PLACEMENT END
IN APPROVED PLASTIC
INSERT
APPLY CURING COMPOUND
TO SLAB EDGE IMMEDIATELY
AFTER FORM IS REMOVED.
1/8"xT/4" CONTINUOUS SAW CUT
(1" MIN) OR STRIP INSERT W/ JT.
FILLER & ELASTOMERIC
SEALANT.
NOTES:
1. SAW CUT JOINTS WITH EARLY ENTRY SAW AS SOON AS THE SLAB CAN SUPPORT THE WEIGHT OF THE SAW CUTTING EQUIPMENT AND CUTTING DOES NOT DAMAGE THE SLAB.
2. INSTALL JOINTS INDICATED ON PLANS UNO. SUBMIT PROPOSED ALTERNATE LOCATIONS OR ADDITIONAL JOINTS NOT SHOWN TO THE CONTRACTING OFFICER FOR APPROVAL.
PROPOSED ALTERNATE LOCATIONS MAY BE REJECTED. MAX JOINT SPACING SHALL BE 24 x SLAB THICKNESS. MAX POUR LENGTH SHALL BE 100'-0" BETWEEN CONSTRUCTION JOINTS. RATIO OF LENGTH TO WIDTH SHALL NOT EXCEED 1.5. TOTAL AREA OF POUR SHALL NOT EXCEED 10,000 SF BETWEEN CONSTRUCTION JOINTS.
3. DISCONTINUE REINFORCEMENT AT CONSTRUCTION JOINTS.
1ST PLACEMENT2ND PLACEMENT
SE
E
PL
AN
T 6"
INDUCED CRACK
1" M
IN
T/
3/16" MAX
1/8" MIN 1/8" x T/4" CONTINUOUS SAW CUT
(1" MIN) OR STRIP INSERT W/ JT
FILLER & ELASTOMERIC SEALANT
PROVIDE 15 MIL VAPOR
BARRIER DIRECTLY
BELOW SLAB TYP
SLAB ON GRADE
SEE PLAN FOR THICKNESS
AND REINFORCING
6" GRANULAR BASE / CAPILLARY
WATER BARRIER TYP
SEE EARTHWORK SPECIFICATIONS
WWR OR REINF
BAR PER PLAN
TYP
0' - 2" CLR
1/ x T
M
AX
BO
T/
R
EI
N F
1/ x T
M
IN
CONSTRUCTION JOINT SAWN CONTROL JOINT SLAB ON GRADE
FOUNDATION
WALL
2"
4"
2'
- 0
(2) #4 x 4'-0"
IN TOP 1/3 OF SLAB
1/2" EXP JOINT
W/ SEALANT UNO
1' - 0"
CLR
1"
CLR
1"
2'
- 0
FOUNDATION WALL
1" C
LR
FLEXIBLE CLOSED
CELL FOAM PLANK
FULL DEPTH OF SLAB
(2) #4 TOP & BOT
1" CLR FROM TOP
2" CLR FROM BOT
TYP
DOUBLE DOOR
INTERIOR
SLAB
PAVEMENT
FOUNDATION WALL
2" C
LR
FLEXIBLE CLOSED
CELL FOAM PLANK
FULL DEPTH OF SLAB
#4 TOP & BOT
1 1/2" CLR FROM TOP
2 1/2" CLR FROM BOT
PERSONNEL DOOR
INTERIOR
SLAB
PAVEMENT
CLR
1"
CLR1"
#4 TOP & BOT
1" CLR FROM TOP
2" CLR FROM BOT
2'
- 0
CJ
C J
(2) #4 x 4'-0"
CENTER IN SLAB
2" 2"
2' - 0" TYP
SEE PLAN FOR SLAB
THICKNESS T
D < 2"
D
T
ADDITIONAL #4 CONT
+ #4 x 3'-0" DIAGONAL
CORNER BARS
OPTIONAL DOWELED
CONSTRUCTION JOINT
T/CONCRETE
ELEV - SEE PLAN
OR TYP PIER DET
BASE PLATE
SEE TYP DETAILS
"T
EM
BE
D M
EN
T
" M
IN
2" 2"
(2) HEAVY HEX NUTS
ASTM A563
SNUG-TIGHT
ANCHOR ROD
SEE ANCHOR ROD
OR COLUMN SCHEDULES
BA
SE
P L
TH
K
PE
R
T
YP
D
ET
S
PE
R
S C
H
ED
U
LE
"G " G
R O
U T
TH
IC
KN
ES
S
"M " M
IN
P
R O
JE
C
TI
O
N
OVERSIZED HOLE
PER SCHEDULE
HEAVY HEX NUT & PL WASHER "T"x"W"x"W"
TOP & BOT/BASE PL PER SCHEDULE
BOT LEVELING NUT & PL WASHER MAY BE
REPLACED WITH SHIM PACK AT CONTRACTOR'S OPTION
ANCHOR ROD SCHEDULE
ANCHOR
DIA
3/4"
HOLE DIA
1 5/16"
WASHER
WIDTH
"W"
WASHER
THK
"T"
2" 1/4"
GROUT
THK
"G"
MIN
PROJ-
ECTION
"M"
2" 3"
FINISHED FLOOR
ELEV - SEE PLAN
2"
B/CONCRETE
ELEV - SEE PLAN
4" M
IN
1" 1 13/16" 3" 3/8" 2" 3"
LE
N
G
TH
TH
R
EA
D12 " M
IN
M
IL
L
FI
N
IS
H
BO
T/
C O
L
BASE PLATE
NOTES
1. GROUT SHALL BE 8,000 PSI NON-SHRINK, NON-
METALLIC GROUT.
2. LEVELING SHIM, PLATE, AND GROUT MAY BE
SUBSTITUTED FOR LEVELING NUT AT
CONTRACTOR'S OPTION.
3. ANCHOR RODS SHALL BE ASTM F1554 ROD
WITH NUTS AND WASHERS AS SHOWN.
4. BASE PLATE TYPE A HAS A THICKNESS OF 1".
5. SEE TYP DET FOR ANCHOR ROD EDGE
DISTANCE.
EM
BE
D M
EN
T
FINISHED FLOOR
AT CANOPIES ONLY APPLY
ASPHALTIC COATING TO
STEEL BELOW GRADE
1/4x3x3 PLATE WASHER
AND NUT (2 PER ROD)
3/4"ø ANCHOR RODS
STEEL COLUMN
SEE PLAN
T/
PI
ER
C
AP
1/4
1/4
TY
P
2"
TYP
2"
7" 7"
7" 7"
NUT
TYPE A/5 S-502
CONCRETE PIER CAP
PER PLAN
BASE PL TYPE B
EQ EQ
STEEL COLUMN
SEE PLAN
1/4
BP TO WF
COL
BASE PLATE
TY
P
2"
TYP
2"
7" 7"
7" 7"
NOTES
1. GROUT SHALL BE 8,000 PSI NON-SHRINK, NON-
METALLIC GROUT.
2. LEVELING SHIM, PLATE, AND GROUT MAY BE
SUBSTITUTED FOR LEVELING NUT AT
CONTRACTOR'S OPTION.
3. ANCHOR RODS SHALL BE ASTM F1554 ROD
WITH NUTS AND WASHERS AS SHOWN.
4. BASE PLATE TYPE B HAS A THICKNESS OF 1".
5. SEE TYP DET FOR ANCHOR ROD EDGE
DISTANCE.
/5 S-502
1"ø ANCHOR RODS
TYPE B
EM
BE
D M
EN
T
" M
IN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
7/23/2020 10:43:21 AM
C:\Users\h2eddkmj\Documents\481544_Revit2018_S_AES_h2eddkmj.rvt
S-502
AES
TY
PI
C
AL
F O
U N
D
AT
IO
N
D
ET
AI
LS
J.
B
U
SH
K.
J
O H
N
SO
N
D . S
M
IT
H
NOT TO SCALE
7 TYPICAL FLOOR DRAIN DETAIL
NOT TO SCALE
1 TYPICAL SLAB ON GRADE CONSTRUCTION JOINT DETAIL
NOT TO SCALE
TYPICAL REENTRANT CORNER
REINFORCING DETAIL
NOT TO SCALE
2 TYPICAL SLAB AT DOOR OPENING DETAIL
NOT TO SCALE
8 TYPICAL DISCONTINUOUS CJ DETAIL
NOT TO SCALE
9 TYPICAL SOG STEP DETAIL
NOT TO SCALE
5 TYPICAL ANCHOR ROD DETAIL
NOT TO SCALE
3 TYPICAL STEEL COLUMN BASE PLATE DETAIL
NOT TO SCALE
TYPICAL BRACED FRAME COLUMN BASE
PLATE W/OUT BRACE DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
VS
OS
OS
OS
OS
OS
OSOS
OS
OSOS
OS
OS
OSOS
OS
OS
OS
TEXT
TEXT
CO
CO
VS VS VS VS
OS
OS
OS
OS
OS
TEXT
TEXT
GFEDC.6C.2CBA
102 103 104 105
124 123
110109
100A
2.7
3.1
3.5
9' - 0" 9' - 0" 9' - 0" 9' - 0" 10' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
10' - 0" 10' - 0" 9' - 0"
9' - 0" 9' - 0" 9' - 0" 9' - 0"
9' - 0" 9' - 0"
9' - 0"
EXP
EXP
EXP
2.6
8' - 0"
12" BULKHEAD
9' - 0"
12' - 2" 13' - 8 1/2"
13' - 8 1/2"
3.2
A-541
Sim
A-541
Sim
EXIT SIGN LOCATION
GWB CEILING
RECESSED CAN LIGHT FIXTURE
SUPPLY DIFFUSER
RETURN GRILLE
2x2 LAY-IN ACOUSTICAL CEILING
FLUORECENT LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
WALL MOUNTED FLUORECENT
LIGHT FIXTURE
OS OCCUPANCY SENSOR
L DAYLIGHTING SENSOR
EXP / EXPOSED
CEILING LEGEND
EXT. METAL SOFFIT
SPOT ELEVATION
VS VACANCY SENSOR
PROJECTION SCREEN
MOVABLE WALL TRACK
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
AREA "A" AREA "B"
KEY PLAN
7/27/2020 1:34:23 PM
C:\Users\h2eddrah\Documents\481544_Revit2018_A_AES_h2eddrah.rvt
A-131
AES
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
"A
M . B
AR
R
Y
B.
A
LL
EN
J.
S
C H
EN
KE
N
FE
LD
ER
W
8-
XX
-X
-X
XX
X
FI
LE
N U
M
BE
R
1/8" = 1'-0"1 REFLECTED CEILING PLAN "A"
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
OS
OS
TE
XT
TE
XT
VS
OS
VS
OS
KJH.6H.1HG
A-302
A-301
A-302
2.7
3.1
3.5
9' - 0"
10' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
EXP
EXP
EXP
A-301
A-302
2.6
12' - 8"
13' - 8 1/2"
13' - 8 1/2"
13' - 8 1/2"
A-302
A-418
L
3.2
12' - 2"
A-802
4' - 0"
EXIT SIGN LOCATION
GWB CEILING
RECESSED CAN LIGHT FIXTURE
SUPPLY DIFFUSER
RETURN GRILLE
2x2 LAY-IN ACOUSTICAL CEILING
FLUORECENT LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
WALL MOUNTED FLUORECENT
LIGHT FIXTURE
OS OCCUPANCY SENSOR
L DAYLIGHTING SENSOR
EXP / EXPOSED
CEILING LEGEND
EXT. METAL SOFFIT
SPOT ELEVATION
VS VACANCY SENSOR
PROJECTION SCREEN
MOVABLE WALL TRACK
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
AREA "A" AREA "B"
KEY PLAN
7/27/2020 1:34:51 PM
C:\Users\h2eddrah\Documents\481544_Revit2018_A_AES_h2eddrah.rvt
A-132
AES
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
"B
M . B
AR
R
Y
B.
A
LL
EN
J.
S
C H
EN
KE
N
FE
LD
ER
W
8-
XX
-X
-X
XX
X
FI
LE
N U
M
BE
R
1/8" = 1'-0"1 REFLECTED CEILING PLAN "B"
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
FIRST FLOOR
0"
T.O. WALL
14' - 0"
T.O. ROOF
25' - 8 1/2"
D C.6 C.2 C B A
A-302
A-302
SNOW GUARD (X6)
STANDING SEAM METAL
ROOF OVER 7"
VENTILATED NAILBASE
(X6)
SNOW GUARD (X6)
7"X7" PREFINISHED
METAL GUTTER (X5)
PREFINISHED VENTED
METAL FASCIA (X7)
BRICK VENEER, THREE
ROWS SOLDIER COURSE
(X2)
BRICK VENEER (X1)
SOLDIER COURSE
ABOVE WINDOW, 1/2"
OFFSET (X2)
BRICK VENEER, TWO
COURSE ACCENT BAND,
1/2" OFFSET (X2)
BRICK VENEER (X1)
ALUMINUM WINDOW,
FIXED, TYP.(X8)
CASTSTONE WINDOW
SILL (X3)
4" X 6" DOWNSPOUT (X5)
TO CAST IRON
DOWNSPOUT BOOT (X5)
RIDGE VENT (X6)
SNOW GUARD (X6)
STANDING SEAM METAL
ROOF OVER 7"
VENTILATED NAILBASE
(X6)
ALUMINUM STOREFRONT
DOORS AND FRAME (X9)
BEJBEJBEJBEJ
RIDGE VENT (X6)
BRAKE METAL COLUMN
COVER (X7)
BRAKE METAL COLUMN
COVER (X7)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
7/24/2020 12:38:57 PM
C:\Users\h2eddrah\Documents\481544_Revit2018_A_AES_h2eddrah.rvt
A-202
AES
EN
LA
R G
ED
E
XT
ER
IO
R
E
LE
VA
TI
O N
S
AN
D
EX
TE
R
IO
R
S C
H
ED
U
LE
S
M . B
AR
R
Y
B.
A
LL
EN
J.
S
C H
EN
KE
N
FE
LD
ER
W
8-
XX
-X
-X
XX
X
FI
LE
N U
M
BE
R
GENERAL NOTES - ELEVATIONS
1 CONTRACTOR TO COORDINATE PENETRATIONS WITH MEP
DRAWINGS AND SHALL FIELD VERIFY EXACT LOCATION &
SIZE OF PENETRATIONS.
2 BRICK EXPANSION JOINTS (BEJ) SHALL BE PROVIDED AT
22'-0" O.C. MAX. CONTROL JOINTS (CJ) SHALL BE PROVIDE
AT 10'-0" O.C. MAX.
3 BASIS OF DESIGN ( BOD ) IS INTENDED TO ESTABLISH
COLOR, PATTERN AND TEXTURE ONLY. THEY ARE NOT
INTENDENT TO LIMIT SELECTION FORM OTHER SUPPLIER.
WHEN ALTERNATE SELECTIONS ARE SUBMITTED, THE
SUBMITTAL SHALL INCLUDE COLOR SAMPLES OF
MATERIALS LISTED FOR COMPARISON.
4 ALL DOWNSPOUTS (DS) ARE TO TERMINATE IN TO A CAST
IRON DOWNSPOUT BOOT.
EXTERIOR FINISH SCHEDULE
MARK COMPONENT BASIS OF DESIGN ( BOD ) FINISH DESCRIPTION
X1 MODULAR BRICK VENEER, 3-5/8" D X 2-1/4" H X 7-5/8" L RED BRICK - MATCH HQ BLDG
ADJACENT TO THE NORTH
COLOR: CAROLINA CERAMICS, CHESTNUT BLEND 0808 WIRE CUT BRICK
X2 MODULAR BRICK VENEER, 3-5/8" D X 2-1/4" H X 7-5/8" L RED BRICK - SHADE DARKER THAN
FIELD BRICK X1
COLOR: RED BRICK - SHADE DARKER THAN FIELD BRICK X1
X3 PRECAST CONCRETE WINDOW SILLS PRECAST SUPPLIER - PROVIDE
SAMPLE
COLOR: DARK BUFF
X4 MORTAR BRIXMENT COLOR: BRIXMENT FLAMINGO 380 MIXED WITH YELLOW SAND ( ANNE ARUNDEL GOLD ) 3/8"
TOOLED CONCAVE JOINT
X5 GUTTERS AND DOWNSPOUT FED SPEC 595B COLOR: 20045
X6 STANDING SEAM METAL ROOF AND RIDGE VENT AND SNOW GUARDS VALSPAR COLOR: 437TR2440 FLUOROTHANE II SR MEDIUM BRONZE (FLOUROTHANE REQUIRED FOR
SSMR PANELS ONLY)
X7 PREFINISHED METAL TRIM AND FLASHING AND BRAKE METALS FED SPEC 595B COLOR: 20045
X8 ALUMINUM WINDOW UNITS KAWNEER COLOR: #40 ANODIZE, MEDIUM TINT
X9 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS KAWNEER COLOR: #40 ANODIZE, MEDIUM TINT X10 HOLLOW METAL DOOR AND FRAME AND COILING OVERHEAD DOOR DARK BRONZE - MATCH ALUM
STOREFRONT
COLOR: DARK BRONZE TO MATCH ALUM STOREFRONT
X11 MECH. YARD FENCE DARK BRONZE - MATCH ALUM
STOREFRONT
COLOR: DARK BRONZE TO MATCH ALUM STOREFRONT
X12 BOLLARD DARK BRONZE - MATCH ALUM
STOREFRONT
COLOR: DARK BRONZE (GLOSS) TO MATCH ALUM STOREFRONT WITH ONE BAND OF
REFLECTIVE TAPE 6" FROM THE TOP
1/4" = 1'-0"A-201
1 ENLARGED NORTH ELEVATION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
D T
J U L
W
2Q R
R
_P la ns -0
FINISH
FLOOR
FRAME TYPE A
HOLLOW METAL
FRAME TYPE B
HOLLOW METAL
FRAME TYPE C
HOLLOW METAL
FRAME TYPE D
HOLLOW METAL
FRAME TYPE E
GL-3
HOLLOW METAL
FRAME TYPE F1
GL-3
ALUMINUM
FRAME TYPE G1
GL-3
HOLLOW METAL
FRAME TYPE H
GL-3
ALUMINUM
FRAME TYPE J
GL-1
ALUMINUM
9'
4"
9'
0"
9'
0"
7'
0"
7'
0"
7'
0"
FRAME TYPE F2
GL-1
ALUMINUM
2"
2" 2"
PER SCHEDULE
2" 2"
4"
PER SCHEDULE
2" 2"
2"
PER SCHEDULE
2" 2"
4"
PER SCHEDULE 8'
8"
7'
0" 1'
4"
10' - 0"
2"
2"
2" 2"
2" 2"
2"
3' - 2" 3' - 2"
PER SCHEDULE
7'
2" 1'
2"
8'
8"
4' - 2"
2"2"
2"
2"
8"
PER SCHEDULE
1'
8"
8' - 10"
2" 2" 2" 2"
2"
2"
1' - 1" PER SCHEDULE 1' - 1"
2" 2"
2" 2"
1'
"2"
10' - 8"
2" 2" 2" 2"
2' - 0" PER SCHEDULE 2' - 0"
2'
0"
10' - 8"
2" 2" 2" 2"
2" 2"
2"
2' - 0" PER SCHEDULE 2' - 0"
GL-3
GL-3
FRAME TYPE G2
GL-3
ALUMINUM
ALUM ALUMINUM
ANOD ANODIZED
BLK BLK
F FLUSH DOOR
FG FULL GLASS DOOR
GL GLAZING
HM HOLLOW METAL
DOOR & WINDOW & LOUVER ABBREVIATIONS
IM INSULATED METAL
INS INSULATED
MTL METAL
PNT PAINTED
S/F STOREFRONT
ST STAINED
WD SOLID-CORE WOOD
DOOR TYPE NDOOR TYPE FG
SEE SCHEDULE
SE
E
SC
H
ED
U
LE
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
7" 4"
2' -1
6" 6"
6"
FINISHED FLOOR
DOOR TYPE F/O/R
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
DOOR TYPE OC -
OVERHEAD COILING
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
DOOR TYPE K
SEE SCHEDULE
SE
E
SC
H
ED
U
LE
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
JU
N
CERTIFIED FINAL
PN
A
JX
F2
FY
, P
AE
R
O M
ED
IC
AL
E
VA
C
U
AT
IO
N
S Q
U
AD
R O
N
TR
AI
N
IN
G
A N
D A
D M
IN
IS
TR
AT
IO
N
F
AC
IL
IT
Y
JB
A
N D
R
EW
S, M
D
LO
U
IS
VI
LL
E D
IS
TR
IC
T
D R
. M
AR
TI
N
L U
TH
ER
K
IN
G J
R . P
LA
C
E
LO
U
IS
VI
LL
, K Y
M . B
AR
R
Y
7/27/2020 1:35:34 PM
C:\Users\h2eddrah\Documents\481544_Revit2018_A_AES_h2eddrah.rvt
A-611
AES
D O
O R
/F R
AM
E
SC
H
ED
U
LE
A
N D
T
YP
ES
M . B
AR
R
Y
B.
A
LL
EN
J.
S
C H
EN
KE
N
FE
LD
ER
W
8-
XX
-X
-X
XX
X
FI
LE
N U
M
BE
R
DOOR SCHEDULE
DOOR NO.
SINGL
E/PAIR
DOOR TYPES DOOR FRAMES
HARDWARE COMMENTS:TYPE
SIZE
GLAZING MATERIAL FINISH
UNDER
CUT
FIRE
RATING
STC
RATING TYPE MATERIAL FINISH
DETAIL
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
100A PAIR FG 6' - 0" 7' - 0" 1 3/4" GL-1 INS ALUM ANOD J ALUM ANOD 1 2 3 01* * ELECTRONIC CYPHER LOCK AT THIS DOOR W/OUT COMMUNICATION
100B PAIR FG 6' - 0" 7' - 0" 1 3/4" GL-1 INS ALUM ANOD H ALUM ANOD 1 2 3 02
102 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
103 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
104 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
105 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
106 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
107 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 A HM PNT 7 8 - 10
108A SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 11
108B SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 11
109A SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 12
109B SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 12
110A PAIR K 6' - 0" 7' - 0" 1 3/4" - WD ST 45 G1 HM PNT 7 8 - 21
110B SINGLE N 3' - 0" 7' - 0" 1 3/4" GL-3 WD ST 45 A HM PNT 7 8 - 22
110C SINGLE N 3' - 0" 7' - 0" 1 3/4" GL-3 WD ST 45 A HM PNT 7 8 - 22
111A SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 12
111B SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 12
112A SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 13
112B SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 9 15
113A PAIR N 6' - 0" 7' - 0" 1 3/4" GL-3 WD ST 45 C HM PNT 7 8 9 23
113B SINGLE OC 8' - 0" 10' - 0" 2" GL-1 INS MTL PNT - MTL PNT 10 11 12 08
113C SINGLE N 3' - 0" 7' - 0" 1 3/4" GL-1 IM PNT B HM PNT 4 5 6 03* * ELECTRONIC CYPHER LOCK AT THIS DOOR W/OUT COMMUNICATION
114 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 9 13
115 SINGLE N 4' - 0" 7' - 0" 1 3/4" GL-3 WD ST 45 A HM PNT 7 8 - 15
116 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 09
117 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 45 E HM PNT 7 8 - 13
118 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 1" 45 A HM PNT 7 8 - 14
119 SINGLE O 3' - 0" 7' - 0" 1 3/4" - HM PNT 3/4 HR A HM PNT 7 8 9 16
120 SINGLE F 3' - 0" 7' - 0" 1 3/4" - IM PNT B HM PNT 4 5 6 07
121 PAIR F 6' - 0" 7' - 0" 1 3/4" - IM PNT D HM PNT 4 5 6 06
123 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 1" 45 A HM PNT 7 8 - 17
124 SINGLE F 3' - 0" 7' - 0" 1 3/4" - WD ST 1" 45 A HM PNT 7 8 - 17
126 SINGLE N 3' - 0" 7' - 0" 1 3/4" GL-4 WD ST 3/4 HR 45 A HM PNT 7 8 9 20
127A SINGLE FG 3' - 0" 7' - 2" 1 3/4" GL-3 ALUM ANOD 45 F1 ALUM ANOD 7 8 - 18
127B SINGLE FG 3' - 0" 7' - 2" 1 3/4" GL-1 INS ALUM ANOD F2 ALUM ANOD 1 2 3 04* * ELECTRONIC CYPHER LOCK AT THIS DOOR W/OUT COMMUNICATION
128A SINGLE R 3' - 0" 7' - 0" 1 3/4" - WD ST 3/4 HR 45 E HM PNT 7 8 9 19
128B SINGLE R 3' - 0" 7' - 0" 1 3/4" - WD ST 3/4 HR 45 E HM PNT 7 8 9 19
128C SINGLE F 3' - 0" 7' - 0" 1 3/4" - IM PNT B HM PNT 4 5 6 05
128D SINGLE F 3' - 0" 7' - 0" 1 3/4" - IM PNT B HM PNT 4 5 6 05
130A PAIR FG 6' - 0" 7' - 0" 1 3/4" GL-1 INS ALUM ANOD J ALUM ANOD 1 2 3 01* * ELECTRONIC CYPHER LOCK AT THIS DOOR W/OUT COMMUNICATION
130B PAIR FG 6' - 0" 7' - 0" 1 3/4" GL-1 INS ALUM ANOD G2 ALUM ANOD 1 2 3 02
1/4" = 1'-0"
DOOR FRAMES TYPES
GLAZING SCHEDULE
GL-1 EXTERIOR INSULATED TEMPERED CLEAR GLAZING
GL-2 EXTERIOR INSULATED TEMPERED FROSTED GLAZING
GL-3 TEMPERED SAFETY GLAZING
GL-4 FIRE RATED GLASS
GENERAL NOTES - DOORS
1 SEE SHEET A-611 FOR DOOR TYPES AND FRAMES
2 FLOOR, WALL & BASE…