W912QR20R0019Plans-0002.pdf
PDF 3 MB Posted
- Attached to
- Modified TEMF at Yakima Training Center (YTC) Federal contract opportunity
- Solicitation number
- W912QR20R0019
About this file
This solicitation is for the construction of a 29,000 square foot Modified Tactical Equipment Maintenance Facility at the Yakima Training Center in Washington. The project cost is estimated between $10-25 million and has been set aside 100% for small businesses under NAICS code 236220 with a size standard of $39.5 million. Funds are not presently available and no contract will be awarded until appropriated funds are made available. Offerors must register in the System for Award Management, which has replaced the Central Contractor Registration and Online Representations and Certifications Application. Technical inquiries should be submitted through the Bidder Inquiry function on ProjNet. The solicitation number is W912QR20R0019 and was issued by the Department of the Army Corps of Engineers Louisville District.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912QR20R0019Plans-0005.pdf | ||
| W912QR20R0019Specs-0005.pdf | ||
| W912QR20R0019Specs-0004.pdf | ||
| W912QR20R0019 Amend 0003.pdf | ||
| W912QR20R0019Specs-0002.pdf | ||
| W912QR20R0019Specs-0001.pdf | ||
| W912QR20R0019Plans-0001.pdf | ||
| Site Walk Sign-in Sheet for solicitation W912QR20R0019.pdf | ||
| W912QR20R0019Plans_Vol2-0000.pdf | ||
| W912QR20R0019Specs_Vol3-0000.pdf | ||
| W912QR20R0019Specs_Vol2-0000.pdf | ||
| W912QR20R0019Specs_Vol1-0000.pdf | ||
| W912QR20R0019Plans_Vol1-0000.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
E 1652348.06
N 493283.35
S E
C U
R I T
Y
F
E N
C E
SECURITY FENCE
NOTES:
KEYPLAN:
X
X
X
X
D E
S I G
N E
D
B
Y
U S
A
R M
Y
C
O R
P S
O
F
E
N G
I N
E E
R S
L O
U I S
V I L L E
D
I S
T R
I C
T
D
R
M
K
N
G
J R
P
L A
C E
L O
U I S
V I L L E
K
E N
T U
C K
Y
D W
N
B
Y
C K
D
B
Y
F I
N
A M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
D A
T E
R A
W I N
G
C
O D
E
X
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K I M
A
T
R A
I N
I N
G
C
E N
T E
R
W
A
E C
S
M
O D
I F
I E
D
T
E M
F
P N
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
P
M
CERTIFIED FINAL SUBMITTAL
M A
R K
D E
S C
R I P
T I O
N D
A T
E
1. SEE SHEET CS100 FOR GENERAL SITE NOTES.
N
M A
T C
H L I N
E
S
H E
T
C
F
N
T I N
U A
T I O
N
MATCHLINE: SEE SHEET CS106 FOR CONTINUATION
N
A1
SITE PLAN 3
SCALE: AS SHOWN
20' 40'0
LEGEND:
CONCRETE PAVEMENT
AGGREGATE SURFACE
C1
C3
CS500
CS500
SECURITY FENCE
C2
CS503
X
FIRE HYDRANT
B2
CU503
BOLLARD
B1
CS505
LIGHT POLE FOUNDATION
CONCRETE SIDEWALK
ASPHALT PAVEMENT (POV)
ASPHALT PAVEMENT (HEAVY DUTY)
A1
CS500
A3
CS500
A3
CS501
B
M C
D D
F S
C
L I E
N T
S A
N F
U
S C
O E
L R
L Y
A K
I M
A T
E M
F D
E S
I G
N C
I V
I L S
H E
E T
S T
E M
F
B
U I L D
I N
G Y
T C
C
S D
W G
A
M
L M
C M
I L L I N
D I C
A T
E D
N O
V E
M B
Y
T C
C
S D
W G
L P
A I N
E
H F
E L L O
W S
A D
O R
M A
N
S I T
E
P
L A
N
CS103
C
E R
T I F
I E
D
F
I N
A L
S
U B
M I T
T A
L
A
M E
N D
M E
W
2Q R
R
Pl an s-
AutoCAD SHX Text P hfellows HMF MO Seal + Signature hfellows Text Box 3/13/2020
X X
X X
X X
X
X X
X X
X X
X X
X X
X
MEP
(BY OTHERS)
SECURITY FENCE
X
X X X X X X X X X X
X X
X X
X X
XXXX
0+00 1+00
E 1652295.51
N 492765.46
E 1652271.03
N 492790.96
E 1652271.56
N 492816.95
E 1652270.52
N 492765.97
E 1652542.32
CONNECT TO EXISTING
SECURITY FENCE
N 492852.14
R
R
R
34' SECURITY
DOUBLE
SWING GATE
SECURITY
FENCE
26.00'
E 1652309.28
N 492803.18
R
E 1652348.04
N 492988.04
E 1652342.05
N 492988.16
E 1652347.23
N 492948.44
E 1652509.22
N 492945.14
E 1652506.75
N 492824.86
E 1652386.78
N 492827.31
R
E 1652279.04
N 492840.09
DUMPSTER
ENCLOSURE
(SEE ARCH
DWGS)
TELECOMM MH
TELECOMM MH
FH1
N
D E
S I G
N E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
D
R
M
N
G
J R
P
L A
C E
L O
U I S
V I L L E
K
E N
T U
C K
Y
D W
N
B
Y
C K
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
D A
T E
A
W I N
G
C
O D
E
X
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K I M
A
T
R A
I N
I N
G
C
E N
T E
R
W
A
E C
S
M
O D
I F
I E
D
T
E M
F
P N
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
P
M
CERTIFIED FINAL SUBMITTAL
M A
R K
D E
S C
R I P
T I O
N D
A T
E
NOTES:
KEYPLAN:
X
X
X
X
N
A1
SITE PLAN 6
SCALE: AS SHOWN
20' 40'0
MATCHLINE: SEE SHEET CS103 FOR CONTINUATION
1. SEE SHEET CS100 FOR GENERAL SITE NOTES.
M A
T C
H L I N
E
S
H E
F
N
T I N
U A
T I O
N
MATCHLINE: SEE SHEET CS107 FOR CONTINUATION
LEGEND:
CONCRETE PAVEMENT
AGGREGATE SURFACE
C1
C3
CS500
CS500
SECURITY FENCE
C2
CS503
X
FIRE HYDRANT
B2
CU503
BOLLARD
B1
CS505
LIGHT POLE FOUNDATION
CONCRETE SIDEWALK
ASPHALT PAVEMENT (POV)
ASPHALT PAVEMENT (HEAVY DUTY)
A1
CS500
A3
CS500
A3
CS501
A3
CS503
B
M C
D D
F S
C
L I E
N T
S A
N F
U
S C
O E
L R
L Y
A K
I M
A T
E M
F D
E S
I G
N C
I V
I L S
H E
E T
S T
E M
F
B
U I L D
I N
G Y
T C
C
S D
A
M
L M
C M
I L L I N
D I C
A T
E D
N O
V E
M B
Y
T C
C
S D
W G
L
P
A I N
E
H
F
E L L O
W S
A
D
O R
M A
N
S I T
E
P
L A
N
CS106
C
E R
T I F
I E
D
F
I N
A L
S
U B
M I T
T A
L
A
M E
N D
M E
W
2Q R
R
Pl an s-
AutoCAD SHX Text P hfellows HMF MO Seal + Signature hfellows
NEMA 4X SS
TERMINATION
ENCLOSURE
PUMP CONTROL
PANEL
SCADA PANEL
#1/0 BC TO
GROUND ROD (TYP)
CONDUIT TO
WET WELL (TYP)
GRADE
POWER CONDUIT
TO ATS
HORN/STROBE
EXPLOSION PROOF
SEAL FITTING
(TYP)
BOLT TO
EQUIPMENT RACK
2"
M
I N
STAINLESS STEEL
STRUT BASE AND
1/2" EXPANSION
ANCHORS (TYP)
M
A X
STAINLESS STEEL
STRUT CHANNEL 41
[1 5/8"], 12GA. (TYP)
(B-LINE B22 OR
EQUIVALENT)
305 [12"] CONCRETE SLAB WITH
#13@305 [#4@12"] EACH WAY,
TOP AND BOTTOM. FINAL PAD
SIZE AS REQUIRED FOR
EQUIPMENT SUPPLIED ALLOWING
A MINIMUM OF 915 [3'-0"] IN FRONT
OF THE EQUIPMENT FACE
#6 BC TO PANEL
GROUNDING LUG
PUMP CONTROL
PANEL (BEHIND)
NEMA 4X S.S.
TERMINATION
ENCLOSURE
STAINLESS STEEL
STRUT SUPPORTS
NOTES:
1. MOUNT SUPPORT HOOK FOR PUMP CABLE ON
OPPOSITE SIDE OF HATCH HINGES.
2. PROVIDE STAINLESS STEEL STRAIN RELIEF GRIP.
GRADE
STAINLESS STEEL
STRUT SUPPORT
BRACING (TYP 2
PLACES)
915 [36"] (MIN)
EQUIPMENT PAD
FRP SLEEVE
WITH LINK SEAL
FINISHED
GRADE
TOP OF WET WELL
CONDUIT BUSHING
HATCH
STAINLESS STEEL
BRACKET (SIZE
AS REQUIRED)
STAINLESS
STEEL HOOK
(SEE NOTE 1)
STRAIN RELIEF GRIP
(SEE NOTE 2)
TO ELECTRICAL
EQUIPMENT RACK
CONCRETE FILL
SUBMERSIBLE
PUMP CABLE
SCALE: N.T.S.
SANITARY SEWER LIFT STATION (LS1)
A1
SCALE: N.T.S.
PRECAST WET WELL - TYPICAL CONDUIT
PENETRATION AND CABLE SUPPORT
A4
SECTION A
SECTION B
B
KEYED NOTES:
PROVIDE AND INSTALL REQUIRED TERMINAL BLOCKS WITHIN THE
TERMINATION ENCLOSURE FOR THE PUMP MOTOR, SEAL PROBES,
THERMAL SWITCHES, FLOAT SWITCHES, AND SUBMERSIBLE
PRESSURE TRANSDUCER CABLES. ALL MANUFACTURER SUPPLIED
CABLING SHALL BE TERMINATED WITHIN THIS ENCLOSURE.
CONTROL AND POWER CIRCUITS SHALL BE SEPARATED WITHIN
THIS ENCLOSURE. CONTRACTOR SHALL PROVIDE THE REQUIRED
CONDUIT AND CABLING BETWEEN THE TERMINATION ENCLOSURE
AND PUMP CONTROL PANEL.
CONTRACTOR SHALL INSTALL MANUFACTURER PROVIDED PUMP
AND CONTROL CABLING IN CONDUITS AS INDICATED.
THE LIFT STATION (LS1) CONTROL PANEL AND ENCLOSURES
SHALL BE MOUNTED TO THE EQUIPMENT SUPPORT RACK.
SCADA PANEL SHALL BE GOVERNMENT SUPPLIED EQUIPMENT.
CONTRACTOR SHALL BE RESPONSIBLE FOR MOUNTING THE
SCADA PANEL AND ASSOCIATED RADIO ANTENNA TO THE
EQUIPMENT RACK. ALL CABLING AND TERMINATIONS BETWEEN
THE SCADA PANEL AND THE PUMP CONTROL PANEL SHALL BE
MADE BY THE CONTRACTOR AS REQUIRED. PROVIDE A MINIMUM
53mm[2"] CONDUIT MAST FOR THE ANTENNA AS REQUIRED.
CONTRACTOR SHALL COORDINATE SPECIFIC ANTENNA MOUNTING
REQUIREMENTS WITH THE OWNER. SECURE ANTENNA MAST TO
THE EQUIPMENT SUPPORT RACK. ANTENNA AND MOUNT ARE NOT
SHOWN IN EQUIPMENT ELEVATION.
THE SUBMERSIBLE PRESSURE TRANSDUCER VENT FILTER
ASSEMBLY SHALL BE MOUNTED WITHIN THE TERMINATION
ENCLOSURE.
PROVIDE A 6" SCHEDULE 80 PVC STILLING WELL. REFER TO PIPE
SUPPORT DETAIL PS-2 ON C-507 FOR STILLING WELL MOUNTING.
TOP OF STILLING WELL SHALL BE AT EL 3.25' AND BOTTOM OF
STILLING WELL SHALL BE AT 6" ABOVE BOTTOM OF WET WELL (EL.
-12.86'). THE TRANSDUCER SHALL BE POSITIONED AT 12" ABOVE
THE BOTTOM OF THE WET WELL (EL. -11.36').
4'-0"
8'-0"
305 [12"] (MIN)
305 [12"] (MIN)
M
A X
305 [12"] (MIN) (TYP)
VALVE VAULT SSVV1
STILLING
WELL
LIT-01
PUMP
NO. 2
PUMP
NO. 1
ACCESS
HATCH
(ABOVE)
CONDUIT
PENETRATION (TYP)
REFER TO DETAIL C4
THIS DWG
INSTRUMENT
ACCESS
HATCH
(ABOVE)
CLASS I
DIVISION 1
HAZARDOUS
LOCATION
CLASS I
DIVISION 2
HAZARDOUS
LOCATION
WET WELL
LIFT STATION SSLS 1
UE
MANUFACTURER SUPPLIED
FLOAT CABLING, 38mm [1 1/2"] C
MANUFACTURER SUPPLIED
PUMP CABLING, 50mm [2"] C
SCADA PANEL
PUMP CONTROL
PANEL
TERMINATION
ENCLOSURE
EQUIPMENT PAD
EQUIPMENT SUPPORT
RACK (TYP)
#1/0 BC (TYP)
#6 BC
EP1-9
REFER ELECTRICAL
FOR CONTINUATION
FENCE
A
3/4" x 10'
COPPERCLAD
STEEL GROUND
ROD (TYP)
24"
(MIN)
MANUFACTURER SUPPLIED
INSTRUMENT CABLING, 25mm [1"] C
MANUFACTURER SUPPLIED
PUMP CABLING, 50mm [2"] C
UE
U
E
U
E
U
E
U E
U E
U E
U E
LSH-01,
LSH-02
1'-6" 1'-6"
BOND BEAM PER
STRUCT
8" CMU WALL, FULLY
GROUTED, W/ #5 @
32 OC VERT
DOWEL TO MATCH CMU
VERT SIZE AND SPACING
IJ (TYP)
SLAB
#5 @ 12" OC EW
SCALE: N.T.S.
CMU WALL
C5
D E
S I G
N E
D
B
Y
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
L O
U I S
V I L
S
T R
I C
T
D
R
M
N
G
J R
P
L A
C E
L O
U I S
V I L L E
K
E N
T U
C K
Y
D W
N
B
Y
C K
D
B
Y
F I
M
E
S I Z
E
P L O
T
S
C A
L E
P
L O
T
D
A T
E
D A
T E
A
W I N
G
C
O D
E
X
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K I M
A
T
R A
I N
I N
G
C
E N
T E
R
W
A
E C
S
M
O D
I F
I E
D
T
E M
F
P N
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
P
M
CERTIFIED FINAL SUBMITTAL
M A
R K
D E
S C
R I P
T I O
N D
A T
E
B
M C
D D
F S
C
L I E
N T
S A
N F
U
S C
O E
L R
L Y
A K
I M
A T
E M
F D
E S
I G
N C
I V
I L S
H E
E T
S T
E M
F
B
U I L D
I N
G Y
T C
C
U D
A
M
L M
C M
I L L I N
D I C
A T
E D
N O
V E
M B
Y
T C
C
U D
W G
L
P
A I N
E
H
F
E L L O
W S
A
D
O R
M A
N
S A
N I T
A R
Y
S
E W
F
T
S
T A
T I O
N
D
E T
A I
CU802
C
E R
T I F
I E
D
F
I N
A L
S
U B
M I T
T A
L
A
M E
N D
M E
W
2Q R
R
Pl an s-hfellows HMF MO Seal + Signature hfellows
GENERAL ROOM FINISH SCHEDULE NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
REFER TO SPECIFICATION 09 06 00 SCHEDULE FOR FINISH
MATERIALS. BASIS OF DESIGN OR EQUIVALENT COLOR AND FINISH
CODES ARE AS INDICATED ON THE ROOM FINISH SCHEDULE.
REFER TO INTERIOR ELEVATIONS, REFLECTED
CEILING DRAWINGS, FLOOR FINISH DRAWINGS, WALL FINISH
DRAWINGS, ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL
DRAWINGS FOR ADDITIONAL FINISH PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS
FOR COORDINATION OF BUILDING FINISHES TO BUILDING
SYSTEMS.
REFER TO FINISH DRAWINGS FOR PLACEMENT OF
FLOOR FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL
CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR
TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.
REFER TO FINISH DRAWINGS AND INTERIOR ELEVATIONS
FOR WALL FINISH EXTENTS, CORNER GUARD LOCATIONS,
SIGNAGE, ART AND SPECIALTY WALL FINISH LOCATIONS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING
HEIGHTS AND CEILING MATERIAL EXTENTS.
REFER TO ENLARGED TOILET DRAWINGS, WALL FINISH PLANS
AND INTERIOR ELEVATIONS FOR PLACEMENT OF INTERIOR
FINISHES IN TOILET/LOCKER ROOMS.
REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR
ELEVATIONS FOR ASSIGNMENT OF SOLID SURFACE AND
PLASTIC LAMINATE FINISHES AND ADDITIONAL INFORMATION.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL
MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET
ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,
COUNTERTOP SUPPORTS, MARKERBOARDS, FLAT PANEL
DISPLAYS, CAMERAS, ACOUSTICAL WALL PANELS, AND
ANY OTHER WALL MOUNTED OBJECT.
UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL
STEEL TO BE PAINTED PA-3.
UNLESS NOTED OTHERWISE, ALL EXTERIOR / PERIMETER
WINDOWS TO RECEIVE ROLLER SHADES (RS-1). ALL WINDOW
SHADES TO BE GFGI.
ALL WINDOW SILLS TO BE SSF-1
ALL DOOR FRAMES AND HOLLOW METAL DOORS TO BE PA-2.
ALL METAL FABRICATIONS AND HANDRAILS TO BE PA-1.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
NO FINISHES REQUIRED ON CONCRETE WALLS OR CONCRETE
CEILINGS UNLESS NOTED OTHERWISE.
ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE
TOP OF THE SCHEDULED WALL BASE.
AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL
EXPOSED SURFACES.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,
MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND
CONDUITS EXCEPT PRE-FINISHED LINER PANELS AND FOAM
GENERATORS. THE PAINT COLOR SHALL BE AS INDICATED
ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR SHALL
BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED PA-1
UNLESS OTHERWISE REQUIRED BY CODE. COORDINATE WITH
MECHANICAL / ELECTRICAL FOR FINISHES
ON MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL
SURFACES, OPERATING PARTS, LABELS OR WARNINGS.
REFER TO AND COORDINATE WITH FURNITURE DRAWINGS
AND TYPICAL MOUNTING HEIGHTS DRAWING FOR WALL
MOUNTING HEIGHTS OF FF&E, VISUAL DISPLAYS AND AUDIO
VISUAL EQUIPMENT.
D E
S
IG
N E
D B
Y
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
.L K
IN
G
J R
P
L A
C E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
D W
N B
Y
C K
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
D A
T E
A F
D R
A W
IN
G
C O
D E
X
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K
IM
A T
R A
IN
IN
G C
E N
T E
R
W A
E C
S M
O D
IF
IE
D T
E M
F P
N
CERTIFIED FINAL SUBMITTAL
/1
/2
:4
:1
P
M
/8
A-701
J T
O P
B B
O R
T Z
A R
E E
S E
/1
/2
J A
N U
A R
Y
A
C
E N
T R
A L
R O
O M
F
IN
IS
H
S C
H E
D U
L E
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR
BASE WALLS
CEILING REMARKSMATERIAL NORTH EAST SOUTH WEST
FINISH FLOOR
101 ADMIN. SHOP CONTROL RF-1 EB-1 PA-1 PA-1 PA-1 PA-1 ACT-1
102 OFFICE RF-1 EB-1 PA-3 PA-1 PA-1 PA-1 ACT-1
103 OFFICE RF-1 EB-1 PA-3 PA-1 PA-1 PA-1 ACT-1
104 OFFICE RF-1 EB-1 PA-1 PA-3 PA-1 PA-1 ACT-1
105 TR RF-2 RB-1 PA-1 PA-1 PA-1 PA-1 PA-5
107 CIRC. CS-1/WOM-1 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1
108 LACTATION RF-1 EB-1 PA-1 PA-3 PA-1 PA-1 ACT-1
109 JANITOR CLOSET CS-1 RB-1 PE-1 PE-1 PE-1/FRP-1 PE-1/FRP-1 PE-5
110 WOMEN TLP-1 TLB-1 PE-1/PE-3 TLC-1/PE-1 TLC-1/PE-1 PE-1 PE-5
111 MEN TLP-1 TLB-1 TLC-1/PE-1 PE-1 PE-1 PE-1/PE-2 PE-5
112 BREAK TRAINING CONFERENCE RF-1 EB-1 PE-1/PA-2 PA-1 PA-1 PA-1 ACT-1
113 PARTS ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
117 TOOL ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
118 FLUID DIST ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
119 SMALL ARMS REPAIR CS-1 - PA-1 PA-1 PA-1 PA-1 -
120 WEAPONS VAULT CS-1 - PA-1 PA-1 PA-1 PA-1 -
121 COMMO ELECTRONICS CS-1 - PA-1 PA-1 PA-1 PA-1 -
122 MAINTENANCE BAYS CS-1 - PA-1 PA-1 PA-1 PA-1 -
123 CIRCULATION BAY CS-1 - PA-1 PA-1 PA-1 PA-1 -
124 REPAIR BAYS CS-1 - PA-1 PA-1 PA-1 PA-1 -
125 MAINTENANCE BAYS CS-1 - PA-1 PA-1 PA-1 PA-1 -
126 REPAIR BAYS CS-1 - PA-1 PA-1 PA-1 PA-1 -
127 ELEC ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
130 FIRE PUMP ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
131 MECHANICAL ROOM CS-1 - PA-1 PA-1 PA-1 PA-1 -
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL MANUF. MODEL NUMBER PRODUCT NUMBER COLOR DESCRIPTION REMARKS
ACOUSTICAL CEILING TILE
ACT-1 ARMSTRONG FINE FISSURED 15/16" 465 WHITE 24" x 24" - ACOUSTICAL CEILING TILE
CONCRETE
CS-1 - - - - SEALED CONCRETE - CLEAR
CORNER GUARD
CG-1 CONSTRUCTION SPECIALTIES CO-8 - STAINLESS STEEL 304 STAIN FINISH, FULL HEIGHT
FLOORING
EB-1 STONHARD STONTEC PORTOBELLO ROAD INTEGRAL EPOXY BASE, SMALL FLAKE, 4"
RF-1 STONHARD STONTEC PORTOBELLO ROAD EPOXY FLAKE RESINOUS FLOORING, SMALL FLAKE
RF-2 TARKETT IQ GRANIT SD 421 0421 SANDLOT STATIC DISSIPATIVE TILE, 12" x 12"
WOM-1 CONSTRUCTION SPECIALTIES PEDIMAT M1 PEWTER WALK-OFF MAT
GROUT
GR-1 TEC SPECIALTIES - ACCUCOLOR 909 STERLING GROUT
PAINT
PA-1 SHERWIN WILLIAMS - SW6070 HERON PLUME LATEX EGGSHELL FINISH
PA-2 SHERWIN WILLIAMS - SW7701 CAVERN CLAY LATEX EGGSHELL FINISH
PA-3 SHERWIN WILLIAMS - SW7066 GRAY MATTERS LATEX EGGSHELL FINISH
PA-4 SHERWIN WILLIAMS - SW7067 CITYSCAPE LATEX SEMIGLOSS FINISH, DOORS & FRAMES
PA-5 SHERWIN WILLIAMS - SW7006 EXTRA WHITE LATEX FLAT MATTE FINISH
PE-1 SHERWIN WILLIAMS - SW6070 HERON PLUME EPOXY EGGSHELL FINISH
PE-2 SHERWIN WILLIAMS - SW7701 CAVERN CLAY EPOXY EGGSHELL FINISH
PE-3 SHERWIN WILLIAMS - SW7066 GRAY MATTERS EPOXY EGGSHELL FINISH
PE-5 SHERWIN WILLIAMS - SW7006 EXTRA WHITE EPOXY FLAT MATTE FINISH
PLASTIC LAMINATE
PLAM-1 WILSONART - 4878-38 PEWTER MESH 487 CASEWORK
RESILIENT BASE
RB-1 ROPPE - 4" RUBBER BASE BURNT UMBER #194 RUBBER BASE
ROLLER SHADES
RS-1 MECHOSHADE 0700 SERIES 0701 WHITE ROLLER SHADE - BLACKOUT FOR USE IN 112 BREAK TRAINING CONFERENCE ONLY
RS-2 MECHOSHADE 1600 SERIES 1610 GRAND ROLLER SHADE
SOLID SURFACE FABRICATION
SSF-1 WILSONART - 9199MG PEARL MIRAGE COUNTERTOPS AND WINDOW SILLS
TERRAZZO
TER-1 - - - LIGHT GREY, MANUFACTURER'S STANDARD TERRAZZO CAST SHOWER PAN
TILE
TLB-1 AMERICAN OLEAN - BRIGHT & MATTE MATTE MUSHROOM 6" x 6", CERAMIC COVE BASE
TLC-1 AMERICAN OLEAN - BRIGHT & MATTE MATTE MUSHROOM 6" x 6", CERAMIC
TLP-1 AMERICAN OLEAN - ELEMENTAL CANVAS CLASSIC GRAY 12" x 24", PORCELAIN
TOILET PARTITIONS
TP-1 SCRANTON PRODUCTS HINY HIDERS - SHALE - OP TOILET PARTITIONS
WALLCOVERING
FRP-1 PANOLAM CLASS C .090 BRIGHT WHITE - TEXTURED FIBERGLASS REINFORCED PLASTIC
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L S
U B
M
IT
T A
L
/1 /2
A
M E
N D
M E
N T
/1
/2
3/13/20
W
2Q R
R
Pl an s-
B
OFFICE
OFFICE
OFFICE
ADMIN. SHOP
CONTROL
TR
CIRC.
WOMEN
MEN
BREAK TRAINING
CONFERENCE
MAINTENANCE BAYS
PARTS ROOM
SMALL ARMS REPAIR
WEAPONS VAULT
COMMO
ELECTRONICS
TOOL ROOM
FLUID DIST ROOM
CH3
QTY 24
CH1
CH2 CH2
CH1
CH2 CH2
CH2
CH2
CH4
CH1
CH1
CH1
CH1
D2
D1
D1
LF53
LF53
D3
LF5 BC5
WA1
SC54SC54SC54SC54
LF5
D3
D3
LF5
SC54 SC54 SC54 SC54
E2
LE1
LF53
LACTATION
JANITOR CLOSET
E4
W1 R1
R1 W1
R1 W1
CH1 CH1
D3D3
CH1
D3
CH1
D3
SC54
ELEC ROOM
FIRE PUMP ROOM
MECHANICAL ROOM
T1 T1 T1 T1
T1T1T1T1
T1 T1 T1 T1
4.1
5.1
109' - 0"
2.8
AV1
QTY.
E2
WA1
CH1
D3
D3
E3
E1
E1
E2
QTY.
LF5
LF5
55 GAL DRUM
STORAGE AREA
30"W x 65"H x 32"D
VERTICAL CYLINDER
LOCKER
3' - 0" 4' - 4"
4" WIDE YELLOW
(FED-STD-595 COLOR
33538) LINE PAINTED
ON METAL GRATING
ALONG EDGE OF
EGRESS ONLY AREA
LF5
LF5
LF5
S1
REQUIRED SPACE RESERVED
FOR FUTURE VENDING MACHINE.
WB1 WB1 WB1 WB1 WB1WB1
WB1 WB1
OT1
W1
B3
I-103
MOBILE HIGH
DENSITY STORAGE
SAT
CH1
DE1
W4
W4
W4
ENCLOSED GLASS
DISPLAY BOARD
WS1 WS1 WS1 WS1
CH1
WS1WS1
CH1CH1
WS1
LF53
CH1 CH1 CH1 CH1
R1
LEGEND
EGRESS AREA
ONLY, NO STORAGE
D E
S
IG
N E
D B
Y
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
.L K
IN
G
J R
P
L A
C E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
D W
N B
Y
C K
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
D A
T E
A F
D R
A W
IN
G
C O
D E
X
KEY PLAN
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K
IM
A T
R A
IN
IN
G C
E N
T E
R
W A
E C
S M
O D
IF
IE
D T
E M
F P
N
A B
CERTIFIED FINAL SUBMITTAL
/1
/2
:4
:1
P
M
/8
I-101
J T
O P
B B
O R
T Z
A R
E E
S E
/1
/2
J A
N U
A R
Y
A
C
E N
T R
A L
F U
R N
IT
U
R E
F L O
O R
P L A
N
A R
E A
A
SCALE: 1/8" = 1'-0"
A1
FURNITURE FLOOR PLAN - AREA A
0 4' 8' 16'
N
FURNITURE SCHEDULE (GFGI)
ITEM
CODE ITEM DESCRIPTION
ACCESSORIES
R1 DESKSIDE RECYCLING - MEDIUM (7 GAL)
W1 WASTEBASKET - MEDIUM (7 GAL)
W4 WASTE RECEPTACLE A-6
CHAIRS
CH1 ERGONOMIC TASK CHAIR
CH3 TRAINING CHAIR
CH4 LOUNGE CHAIR
DESKS
D1 U-SHAPED DESK - 8' x 5' REAR OVERHEAD
D3 DUAL PEDESTAL DESK - 72"W
FILES & STORAGE
BC5 SHELVING - 18"D
LF5 LATERAL FILE 5 DRAWER - 36"W
LF53 LATERAL FILE 5 DRAWER - 30"W
SAT SAT STORAGE SYSTEM
SC54 STORAGE CABINET
FURNITURE SYSTEMS
WS1 L-SHAPED WORKSTATION - 8' x 6'
TABLES
LE1 LECTERN
WA1 WORKBENCH WITH SHELF RISER
WB1 WORKBENCH
NOTE:
FURNITURE SHOWN FOR LAYOUT PURPOSES ONLY. ALL FURNITURE WILL BE
PURCHASED AND INSTALLED UNDER A SEPERATE CONTRACT.
EQUIPMENT SCHEDULE (GFGI)
ITEM
CODE ITEM DESCRIPTION
EQUIPMENT
DE1 INDUSTRIAL PORTABLE DEHUMIDIFIER
E1 REFRIGERATOR
E2 MICROWAVE
E3 COFFEE MAKER
E4 UNDERCOUNTER REFRIGERATOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L S
U B
M
IT
T A
L
/1 /2
A
M E
N D
M E
N T
/1
/2
1 1
3/13/20
W
2Q R
R
Pl an s-
A B
470-12"x10"
SA-D
(4)555-20"x10"
SA-A
12"x10" SA
10"ø SA
12"ø SA
12' - 3" BOD EL
14"ø SA
VAV-110
VAV-109
VAV-107
VAV-108
8"ø EA
-4' - 2" BOD EL
EF-104 (3)900-16"x9"
EA-D
900-16"x10" (TYP 3)
12" AFF
26"ø EA
22"ø EA
23' - 5" BOD EL
18"ø EA
2" AFF
UH-104
UH-102
UH-101
"ø
E A
A1
M-302
ESS
ELEC ROOM
FIRE PUMP ROOM
MECHANICAL ROOM
TOOL ROOM
FLUID DIST ROOM
PARTS ROOM
OFFICE
OFFICE
OFFICE
ADMIN. SHOP
CONTROL
TR
LACTATION
JANITOR CLOSET
BREAK TRAINING
CONFERENCE
MAINTENANCE BAYS
WEAPONS VAULT
COMMO
ELECTRONICS
EF-108
VAV-111
EF-107
EF-106
(2)190-8"x8"
EA-D
12"x12" EA
6"ø SA
140-8"x6"
SA-D 515-10"x10"
SA-D
12"x10" SA
14"ø SA
23' - 11" BOD EL
14"ø SA
12' - 1" BOD EL
400-18"x12"
RA-D
SMALL ARMS REPAIR
T
T
T T
T
20"ø SA
11' - 10" BOD EL
(2)185-8"x8"
EA-D
30"ø SA
19' - 3" BOD EL
(10)540-18"x6"
SA-A
A1
M-401
B3
M-301
A1
M-402
RA-D
NA-12"x6"
RA-D
NA-18"x12"
RA-D
NA-24"x12"
340-12"x6"
SA-A
12"x6" SA
4"ø SA
TM
MEN
WOMEN
CIRC.
24"x24" RA
24"x24" RA
15' - 4" BOD EL
20"ø SA
14' - 8" BOD EL
18"x14" RA
15' - 9" BOD EL
RA-D
NA-18"x12"
RA-D
NA-12"x12"
RA-D
NA-12"x6"
18"x14" RA
13' - 4" BOD EL
14"x14" RA
50-8"x6"
EA-D
COCO
20"ø SA 19' - 8" BOD EL16"ø SA
16"ø RA
RA-D
NA-36"x12"
(3)250-12"x6"
SA-A
14"ø SA
7' - 6" BOD EL
(6)170-9"x6"
SA-A
6"ø EA
11' - 9" BOD EL
EF-109
M
M
A2
M-302
6' x 6' LOUVER
5' x 4' LOUVER
42"x42" EA
26"ø EA
4'x3'6" LOUVER
(2)105-8"ø
EA-D
B5
M-301
CAR-101
NOx NOx
14"ø SA
M
D E
S
IG
N E
D B
Y
U.S. FEDERAL GOVERNMENT HAS UNLIMITED REPRODUCTION RIGHTS
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
.L K
IN
G
J R
P
L A
C E
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
D W
N B
Y
C K
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
P
L O
T D
A T
E
D A
T E
A F
D R
A W
IN
G
C O
D E
X
KEY PLAN
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 432
A
B
C
D
US Army Corps of Engineers
Louisville District
SHEET ID
Y A
K
IM
A T
R A
IN
IN
G C
E N
T E
R
W A
E C
S M
O D
IF
IE
D T
E M
F P
N
A B
CERTIFIED FINAL SUBMITTAL
/1
/2
:2
:1
A
M
/8
M-101
S L
IF
F E
R T
H
R J O
R D
A N
J S
M
IT
H
/1
/2
J A
N U
A R
Y
M
C
E N
T R
A L
M E
C H
A N
IC
A
L H
V A
C P
L A
N A
R E
A A
SCALE: 1/8" = 1'-0"A1
FIRST FLOOR - HVAC PLAN - AREA A
GENERAL NOTES:
SEE SHEET M-001 FOR GENERAL NOTES,
ABBREVIATIONS AND LEGEND.
CONSTRUCT A 24" DEEP PLENUM BOX
BEHIND LOUVERS FOR CONNECTION TO
DUCTWORK. PITCH THE BOTTOM OF THE
PLENUM BOXES TOWARD THE LOUVER
OPENING.
1.
2.
N
0 4' 8' 16'
M A
T C
H L
IN
E
S E
E S
H E
E T
M -1
F
O R
C O
N T
IN
U
A T
IO
N
KEYED NOTES:
DUCT LOCATED BELOW SLAB SHALL BE
FIBERGLASS REINFORCED PLASTIC (FRP).
DEHUMIDIFIER. REFER TO ARCHITECTURAL
PLAN. DEHUMIDIFIER IS GOVERNMENT
FURNISHED AND GOVERNMENT
INSTALLED.
LOCATE BOTTOM OF EXHAUST GRILLES A
MAXIMUM OF 12" ABOVE THE CONCRETE
FLOOR OF THE SERVICE PIT. DUCT IS
SHOWN IN SECTION C1 ON SHEET P-301.
PROVIDE A MOTORIZED DAMPER TO
OPERATE IN CONJUNCTION WITH THE
ROOM EXHAUST FAN. REFER TO
CONTROLS DRAWINGS FOR OPERATIONAL
REQUIREMENTS.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
C
E R
T
IF
IE
D
F
IN
A L S
U B
M
IT
T A
L
/1
/2
A
M E
N D
M E
N T
/1 /2
3/13/2020
W
2Q R
R
Pl an s-
2Q R
R
Pl an s-
| TEMF AMENDMENT 0002 |
| CS103 - SITE PLAN 3 |
| CS106 - SITE PLAN 6 |
| CU802 - SANITARY SEWER LIFT STATION DETAILS 2 |
| A-701 - ROOM FINISH SCHEDULE |
| I-101 - FURNITURE FLOOR PLAN -AREA A |
| M-101 - MECHANICAL HVAC PLAN AREA A |
| ES101 - ELECTRICAL SITE PLAN |