This solicitation package includes construction plans and specifications for an HVAC system upgrade project at two pole barns located in Olmsted, Illinois. Work will consist of installing new HVAC equipment including air conditioning, heating, ventilation fans, louvers, and carbon monoxide detectors. Ductwork and controls will also be provided.

The opportunity is a 100% woman-owned small business set-aside with an estimated value between $1 million to $5 million. The NAICS code is 236220 for commercial and institutional building construction. Proposals are due through the Army Corps of Engineers district office in Louisville, Kentucky. Any questions must be submitted through the Project Network website.

View the file

Other files for this federal contract opportunity

Other files attached to Olmsted Pole Barns 1 & 2, Olmsted IL, newest first.
File Type Posted
Bid Opening Results.pdf PDF
W912QR20B0016Specs-0003.pdf PDF
W912QR20B0016Specs-0002.pdf PDF
W912QR20B0016Plans-0002.pdf PDF
W912QR20B0016Specs-0001.pdf PDF
W912QR20B0016Plans-0001.pdf PDF
W912QR20B0016Plans-0000.pdf PDF
W912QR20B0016Specs-0000.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STORAGE

CONDITIONED

STORAGE

T

HP-1

AC-1

CO

SW

VENTILATION FAN

ON/OFF SWITCH

4FT A.F.F.

EF-1

EF-2

L-1

L-2

GRAVITY BACKDRAFT DAMPER

DH-1

L-3

GRAVITY BACKDRAFT DAMPER

GRAVITY BACKDRAFT DAMPER

GRAVITY BACKDRAFT DAMPER

L-4

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

O

LM

ST

ED

IL

PN

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

WH1

WH2

NNN

1-M-101

WH 1

H

VA

C F

LO

O

R P

LA

N

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

1/8" = 1'-0"1-M-101

HVAC FLOOR PLAN1

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

EXHAUST FAN

OSHA PERSONNEL

GUARD BY FAN

MANUFACTURER

ANGLE SUPPORT

AND CLOSURE

WALL

LOUVER

EXHAUST W/

BIRDSCREEN

GRAVITY BACKDRAFT

DAMPER WALL MOUNT COLLAR

BY FAN MANUFACTURER

HEX. NUT

HEX. NUT

HEX. NUT

STEEL

BEARING

PLATE

HANGER

ROD

TYPICAL

6" LONG HANGER

ROD WITH R.H.

AND L.H. THREAD

FLAT

WASHER

FLAT

WASHER STEEL ANGLE,

SIZE AS

REQUIRED

LOCKWASHER

R.H. THREAD

L.H. THREAD

TURNBUCKLE

2-HEX. NUTS

FLAT WASHER

NOTES:

1. THE CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE

WITH MANUFACTURER'S RECOMMENDATIONS.

CL.

3"

ENCLOSURE,

SEE NOTE 1

STRUCTURE OR

BUILDING WALL

SHOWN AS

PANEL

EXTERIOR FACE

LOUVER,

SEE NOTE 3

BIRDSCREEN,

SEE NOTE 4

CAULKING,

SEE NOTE 5

11/2"

RETURN

ALL AROUND

ENCLOSURE

GRAVITY

BACKDRAFT

DAMPER, WHERE

APPLICABLE

ANGLE,

SEE NOTE 2 LOUVER WITH GRAVITY BACKDRAFT DAMPER INSTALLATION NOTES:

1. SHEET METAL ENCLOSURE (GALV.) SIZE TO BE DETERMINED

BY EXHAUST FANS AND LOUVERS FURNISHED. SECURED

ENCLOSURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS

WITH EXPANSION SHIELDS. SHEET METAL SCREWS IF

WALL PANELS ARE USED.

2. SHEET METAL ANGLE CONTUNUOUS ALL AROUND ENCLOSURE.

SECURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS WITH

EXPANSION SHIELDS AND SECURE TO ENCLOSURE WITH

BOLTS. SHEET METAL SCREWS IF WALL PANELS ARE USED.

3. FIXED WEATHERPROOF LOUVER, MANUFACTURER'S STANDARD

SIZE. SECURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS WITH

EXPANSION SHIELDS, SHEET METAL SCREWS IF WALL PANELS

ARE USED.

4. REMOVE BIRD SCREEN WITH CONTINUOUS FRAME, SCREEN AND

FRAME TO BE GALV. SECURE TO STRUCTURE WALL AND SHEET

METAL ENCLOSURE WITH 1/4" DIA. BOLTS WITH EXPANSION SHIELDS,

WITH EXPANSION SHIELDS, SHEET METAL SCREWS IF WALL

PANELS ARE USED.

5. COULK ALL AROUND SHEET METAL ENCLOSURE WITH SEALANT.

6. FOR ACTUAL WALL OR ROOF SECTION, SEE ARCHITECTURAL

SHEETS.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

ST

ED

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

1-M-501

WH 1

H

VA

C D

ET

AI

LS

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

NTS1 DIRECT-DRIVE WALL EXHAUST FAN DETAIL

NTS2 EQUIPMENT SUPPORT DETAIL

NTS3 GRAVITY BACKDRAFT DAMPER DETAIL

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

AIR TO AIR HEAT PUMP UNIT SCHEDULE (AC-1/HP-1)

MARK TOTAL

REQ.

LOCATION TYPE OF

SYSTEM

AC-1/HP-1

SERVICE REMARKS

1 ROOM 102 ROOM 102CEILING

SUSPENDED,

SPLIT SYSTEM

NOTES:

1. SET THERMOSTAT AT 78 DEG F SUMMER AND 64 DEG F WINTER.

2. UNIT SHALL BE ENERGY STAR CERTIFIED.

3. CONDENSATE DRAIN SHALL RUN TO EXTERIOR WALL AND DISCHARGE OUTSIDE AT 1FT A.F.F. INSULATE INTERIOR CONDENSATE DRAIN WITH FLEXIBLE ELASTOMERIC CELLULAR, ASTM C534/C534M, TYPE I

3. INSULATE REFRIGERANT PIPING WITH FLEXIBLE ELASTOMERIC CELLULAR, ASTM C534/C534M, TYPE I.

COOLING COIL

MINIMUM

TOTAL (BTUH)

HEATING COIL

MINIMUM

SENSIBLE (BTUH)

7,830 9,000

MINIMUM

TOTAL

(BTUH)

6,900

ELECTRICAL

PH

208 3

HZ

V

MINIMUM

SEER

SEE NOTES22

MINIMUM

HSPF

FAN SCHEDULE

MARK TOTAL

REQ'D

EF-2

SERVICE MAX.

(HP)

ELECTRICAL

REMARKS

E.S.P.

IN.

W.C. VOLTS PHASE HERTZ

EF-1 1 ROOM 101 0.25 3/4 115 1 60 SEE NOTE

FAN

TYPE

PROPELLER

DIRECT DRIVE

MOUNTING CFM

ROOM 101

SIDE WALL

PROPELLER

DIRECT DRIVE

SIDE WALL 0.25 3/4 115 1 60 SEE NOTE

NOTE:

1. EF-1 & EF-2 SHALL BE INTERLOCKED WITH WALL MOUNTED ON/OFF SWITCH.

LOUVER SCHEDULE

MARK TOTAL

REQ'D

MIN. FREE

AREA (SF) LOCATION REMARKSSERVICE

SIZE

(W X H)

IN.

L-1

L-2

6.9

6.9

EXTERIOR WALL

RM 101 EF-1 &EF-2 EXHAUST 44X44

44 X 44

EXTERIOR WALL

RM 101

SEE NOTES

SEE NOTES

NOTES:

1. PROVIDE EXTERIOR REMOVABLE BIRDSCREEN ON ALL LOUVERS.

2. FIXED WEATHER PROOF & DRAINABLE BLADE TYPE LOUVERS.

3. LOUVER SHALL BE EQUIPPED WITH GRAVITY BACKDRAFT DAMPER.

EF-1 &EF-2 EXHAUST

L-3

L-4

6.9

6.9

EXTERIOR WALL

RM 101 EF-1 &EF-2 EXHAUST 44X44

44 X 44

EXTERIOR WALL

RM 101

SEE NOTES

SEE NOTES EF-1 &EF-2 EXHAUST

DEHUMIDIFIER UNIT SCHEDULE (DH-1)

MARK TOTAL

REQ'D

MINIMUM

CAPACITY (PINT

PER DAY)

LOCATION REMARKSSERVICE

DH-1 1921 RM 102 RM 102 SEE NOTES

NOTES:

1. UNIT SHALL USED REFRIGERANT TYPE R410A.

2. UNIT SHALL BE ENERY STAR CERTIFIED, UL AND cUL LISTED.

3. CONDENSATE DRAIN SHALL RUN TO EXTERIOR WALL AND DISCHSRGE OUTSIDE AT 1FT A.F.F. INSULATE CONDENSATE DRAIN WITH FLEXIBLE ELASTOMERIC CELLULAR, ASTM C534/C534M, TYPE I.

ELECTRICAL

(V/PH/HZ)

115/1/60

CARBON MONOXIDE UNIT SCHEDULE (CO)

MARK TOTAL

REQ'D

DETECTION

RANGE (PPM)

LOCATION REMARKSSERVICE

CO 0-1501 RM 101 RM 101 SEE NOTES

NOTES:

1. UNIT SHALL OPERATE 0 - 104 oF AND 0 - 90 %RH.

2. UNIT SHALL BE ENERY STAR CERTIFIED, UL AND cUL LISTED.

3. UNIT SHALL BE ABLE TO BE MOUNTED ON THE WALL.

ELECTRICAL

(V/PH/HZ)

115/1/60

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

ST

ED

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

1-M-601

WH 1

H

VA

C S

C H

ED

U

LE

S

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

NOTE: CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS

OF DESIGN.

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

EF-2

EF-1

L-2 WITH GRAVITY

BACKDRAFT DAMPER

L-1 WITH GRAVITY

BACKDRAFT DAMPER

SW

VENTILATION FANS

ON/OFF SWITH

4FT A.F.F.

STORAGE

L-3 WITH GRAVITY

BACKDRAFT DAMPER

L-4 WITH GRAVITY

BACKDRAFT DAMPER

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

ST

ED

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

NN

WH1

WH2

N

2-M-101

WH 2

H

VA

C F

LO

O

R P

LA

N

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

1/8" = 1'-0"1 HVAC FLOOR PLAN

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

EXHAUST FAN

OSHA PERSONNEL

GUARD BY FAN

MANUFACTURER

ANGLE SUPPORT

AND CLOSURE

WALL

LOUVER

EXHAUST W/

BIRDSCREEN

GRAVITY BACKDRAFT

DAMPER WALL MOUNT COLLAR

BY FAN MANUFACTURER

CL.

3"

ENCLOSURE,

SEE NOTE 1

STRUCTURE OR

BUILDING WALL

SHOWN AS

PANEL

EXTERIOR FACE

LOUVER,

SEE NOTE 3

BIRDSCREEN,

SEE NOTE 4

CAULKING,

SEE NOTE 5

11/2"

RETURN

ALL AROUND

ENCLOSURE

GRAVITY

BACKDRAFT

DAMPER, WHERE

APPLICABLE

ANGLE,

SEE NOTE 2 LOUVER WITH GRAVITY BACKDRAFT DAMPER INSTALLATION NOTES:

1. SHEET METAL ENCLOSURE (GALV.) SIZE TO BE DETERMINED

BY EXHAUST FANS AND LOUVERS FURNISHED. SECURED

ENCLOSURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS

WITH EXPANSION SHIELDS. SHEET METAL SCREWS IF

WALL PANELS ARE USED.

2. SHEET METAL ANGLE CONTUNUOUS ALL AROUND ENCLOSURE.

SECURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS WITH

EXPANSION SHIELDS AND SECURE TO ENCLOSURE WITH

BOLTS. SHEET METAL SCREWS IF WALL PANELS ARE USED.

3. FIXED WEATHERPROOF LOUVER, MANUFACTURER'S STANDARD

SIZE. SECURE TO STRUCTURE WALL WITH 1/4" DIA. BOLTS WITH

EXPANSION SHIELDS, SHEET METAL SCREWS IF WALL PANELS

ARE USED.

4. REMOVE BIRD SCREEN WITH CONTINUOUS FRAME, SCREEN AND

FRAME TO BE GALV. SECURE TO STRUCTURE WALL AND SHEET

METAL ENCLOSURE WITH 1/4" DIA. BOLTS WITH EXPANSION SHIELDS,

WITH EXPANSION SHIELDS, SHEET METAL SCREWS IF WALL

PANELS ARE USED.

5. COULK ALL AROUND SHEET METAL ENCLOSURE WITH SEALANT.

6. FOR ACTUAL WALL OR ROOF SECTION, SEE ARCHITECTURAL

SHEETS.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

ST

ED

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

2-M-501

WH 2

H

VA

C D

ET

AI

LS

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

NTS1 DIRECT-DRIVE WALL EXHAUST FAN DETAIL

NTS2

WALL LOUVER WITH GRAVITY BACKDRAFT DAMPER

DETAIL

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

FAN SCHEDULE

MARK TOTAL

REQ'D

EF-2

SERVICE MAX.

(HP)

ELECTRICAL

REMARKSE.S.P.

IN.

W.C. VOLTS PHASE HERTZ

EF-1 1 STORAGE ROOM 0.25 3/4 115 1 60 SEE NOTE

FAN

TYPE

PROPELLER

DIRECT DRIVE

MOUNTING CFM

STORAGE ROOM

SIDE WALL

PROPELLER

DIRECT DRIVE

SIDE WALL 0.25 3/4 115 1 60 SEE NOTE

NOTE:

1. EF-1 & EF-2 SHALL BE INTERLOCKED WITH WALL MOUNTED ON/OFF SWITCH.

LOUVER SCHEDULE

MARK TOTAL

REQ'D

MIN. FREE

AREA (SF) LOCATION REMARKSSERVICE

SIZE

(W X H)

IN.

L-1

L-2

6.9

6.9

EXTERIOR WALL

STORAGE ROOM

EF-1 &EF-2 EXHAUST 44X44

44 X 44

SEE NOTES

SEE NOTES

NOTES:

1. PROVIDE EXTERIOR REMOVABLE BIRDSCREEN ON ALL LOUVERS.

2. FIXED WEATHER PROOF & DRAINABLE BLADE TYPE LOUVERS.

3. LOUVER SHALL BE EQUIPPED WITH GRAVITY BACKDRAFT DAMPER.

EF-1 &EF-2 EXHAUSTEXTERIOR WALL

STORAGE ROOM

L-3

L-4

6.9

6.9

EXTERIOR WALL

STORAGE ROOM

EF-1 &EF-2 EXHAUST 44X44

44 X 44

SEE NOTES

SEE NOTES EF-1 &EF-2 EXHAUSTEXTERIOR WALL

STORAGE ROOM

CARBON MONOXIDE UNIT SCHEDULE (CO)

MARK TOTAL

REQ'D

DETECTION

RANGE (PPM)

LOCATION REMARKSSERVICE

CO 501 RM 103 RM 103 SEE NOTES

NOTES:

1. UNIT SHALL OPERATE 0 - 104 oF AND 0 - 90 %RH.

2. UNIT SHALL BE ENERY STAR CERTIFIED, UL AND cUL LISTED.

3. UNIT SHALL BE ABLE TO BE MOUNTED ON THE WALL.

ELECTRICAL

(V/PH/HZ)

115/1/60

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

O

LM

ST

ED

W

AR

EH

O

U

SE

ST

ED

4, F Y2

LO

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

Y

CERTIFIED FINAL

JU

N

E

D R

AW

IN

G C

O D

E:

M

. S C

H

EN

KE

N

FE

LD

ER

W

2Q R

B0

2-M-601

WH 2

H

VA

C S

C H

ED

U

LE

S

M . S

U

FI

V.

N

G U

YE

N

V.

N

G U

YE

N SE

C O

N D

T

IT

LE

NOTE: CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE STANDARD OF QUALITY AND CHARACTERISTICS OF THE BASIS

OF DESIGN.

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

8/

/2

W

2Q R

B0

6P la ns

-0

1-M-101
1-M-501
1-M-601
2-M-101
2-M-501
2-M-601

File details come from the government source that posted it. Updated .