TE_1_Doors-Windows-Lintels-Plates.pdf
PDF 2 MB Posted
- Attached to
- Window frames, Doors, Lintels and Steel Plates
- Solicitation number
- W912QM-19-Q-0072
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_W912QM-19-Q-0072.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
SHEET 2 OF 14
M E
D I U
M
C
L I N
I C
F L O
O R
P
L A
N
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
5 November 2017
Tojocaz Medium Size Clinic
1. NOTES FOR DOORS
2. Contractor shall apply one coat of anticorrosive primer and two coats of anticorrosive paint to the door and frame.
3. Contractor shall provide commercial grade locks and hardware.
4. Contractor shall provide one master key for exterior doors and one master key for interior doors. Contractor shall provide a total of 3 key sets for schools, clinic, and latrines.
5. Door shall includes frame, handles, stopper with hook, sill, sweep, backing rod, weather strips, anchor bolts, jambs, and accessories to proper frame and door installation.
6. Door and frame welding finishes shall be clean and professional.
7. Contractor shall validate all door opening dimensions before fabrication.
E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
D2
D1
DOOR MATERIAL
HOLLOW METAL
SIZE W/O JAMB
5'-0" X 6'-8" X 1 3/4 " (DOUBLE)
D3
INT/EXT FINISH
EXTERIOR PAINTED
INTERIOR
INTERIOR
HOLLOW METAL
HOLLOW METAL
3'-0" X 6'-8" X 1 3/4 " (LH)
3'-0" X 6'-8" X 1 3/4 " (RH)
PAINTED
PAINTED
SHEET 5 OF 14
M E
D I U
M
C
L I N
I C
O P
E N
I N
G
S
H E
E T
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
5 November 2017
WINDOW
W1
ROUGH OPENING SIZE
6'-0" X 3'-4" X 0'-7-5/8"
TYPE
LOCAL PURCHASE
NOTES
REFER TO MANUFACTURERS SPECS FOR INSTALLATOIN
D5
D4 HOLLOW METAL
2'-8" X 6'-8" X 1 3/4 " (RH)
INTERIOR PAINTED
EXTERIORHOLLOW METAL
3'-0" X 6'-8" X 1 3/4 " (LH)
PAINTED
W2 2'-0" X 3'-4" X 0'-7-5/8" LOCAL PURCHASE
REFER TO MANUFACTURERS SPECS FOR INSTALLATOIN
Tojocaz Medium Size Clinic
PI
T
TO
IL
ET
S
EA
T
TO
IL
ET
P
A
PE
R H
O
LD
ER
25'-4"
5'-4"
25'-4" 25'-4"
5'-4"
25'-4"
8'-8"
8' 6' 26' 6' 24'-8" 6' 26' 6' 17'-4"
126'-1"
3' 10'-11"
140'
8' 6' 7'-4" 3'-4" 15'-4" 6' 7'-4" 3'-4" 3'-4" 3'-4" 7'-4" 6' 15'-4" 3'-4" 7'-4" 6' 9'-4" 3'-4" 4'-8"
CLASSROOM 1 CLASSROOM 2 CLASSROOM 3 CLASSROOM 4
KITCHEN
A
B
C
D
E
1 2 3 4 5
6 7
F
7 8
A
B
C
D
E
F
F L
O O
R
P
L A
N
A
S H
E E
F
B T
H
H
A
S
I T
E
H U
E H
U E
T E
N A
N G
O
G
U A
T E
M A
L A
D A
T E
D
E C
S
C A
L E
D R
A W
N
B
Y
S
G
V
E R
S D
E S
I G
N E
D
B
Y
S
V
E R
S A
P P
R O
V E
D
B
Y
D A
T E
R E
V
D E
S C
R I P
T I O
N R
E V
B
Y A
P P
D
B
Y
854 EN BN, HHC CMS S/D
411 EN BDE
NORTH ARROW
TH
G G
A L
D E
A
E
L
P
A L
M A
R
S
N
D
C
H
O O
L
5'-4"
5. SEE SEPERATE DRAWING FOR 5 STALL LATRINE
Aldea Eucalipto Zona 7 - 4 rooms school
1. NOTES FOR DOORS
2. Contractor shall apply one coat of anticorrosive primer and two coats of anticorrosive paint to the door and frame.
3. Contractor shall provide commercial grade locks and hardware.
4. Contractor shall provide one master key for exterior doors and one master key for interior doors. Contractor shall provide a total of 3 key sets for schools, clinic, and latrines.
5. Door shall includes frame, handles, stopper with hook, sill, sweep, backing rod, weather strips, anchor bolts, jambs, and accessories to proper frame and door installation.
6. Door and frame welding finishes shall be clean and professional.
7. Contractor shall validate all door opening dimensions before fabrication.
W2
At the kitchen a Window 2 shall be added
AutoCAD SHX Text
E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
D2
D1
DOOR MATERIAL
HOLLOW METAL
SIZE W/O JAMB
3'-0" X 6'-8" X 1 3/4 " (RH)
D3
INT/EXT FINISH
EXTERIOR PAINTED
INTERIOR
INTERIOR
HOLLOW METAL
HOLLOW METAL
3'-0" X 6'-8" X 1 3/4 " (LH)
3'-0" X 6'-8" X 1 3/4 " (RH)
PAINTED
PAINTED
WINDOW
W1
ROUGH OPENING SIZE
6'-0" X 3'-4" X 0'-7-5/8"
TYPE
LOCAL PURCHASE
NOTES
REFER TO MANUFACTURERS SPECS FOR INSTALLATOIN
SHEET 5 OF 12
T H
R E
E
R
O O
M
S
C H
O O
L
O P
E N
I N
G
S
H E
E T
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
5 November 2017
Aldea Eucalipto Zona 7 - 4 rooms school
7'-4" 8' 5'-4" 8' 8' 6' 3'-4" 9'-4" 3'-4" 7'-4" 6' 8'
90' - 8"
5'-4"
57'-3
" 25' - 4"
10' - 8"
A
B
C
D
E
1 2 3 4 5 6 7 8
F
7 8
A
B
C
D
E
F
F L
O O
R
P
L A
N
A
S H
E E
F
B T
H
H
T
E
H U
E H
U E
T E
N A
N G
O
G
U A
T E
M A
L A
D A
T E
D
S
C A
L E
D R
A W
N
B
Y
S
V
E R
S
D E
S I G
N E
D
B
Y
S
V
E R
S A
P P
R O
V E
D
B
Y
D A
T E
R E
V
D E
S C
R I P
T I O
N R
E V
B
Y A
P P
D
B
Y
854 EN BN, HHC CMS S/D
411 EN BDE
NORTH ARROW
TH
G G
I N
J V
Inst. Nac. Educ Div Los Olivos open room school
1. NOTES FOR DOORS
2. Contractor shall apply one coat of anticorrosive primer and two coats of anticorrosive paint to the door and frame.
3. Contractor shall provide commercial grade locks and hardware.
4. Contractor shall provide one master key for exterior doors and one master key for interior doors. Contractor shall provide a total of 3 key sets for schools, clinic, and latrines.
5. Door shall includes frame, handles, stopper with hook, sill, sweep, backing rod, weather strips, anchor bolts, jambs, and accessories to proper frame and door installation.
6. Door and frame welding finishes shall be clean and professional.
7. Contractor shall validate all door opening dimensions before fabrication.
E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
D2
D1
DOOR MATERIAL
HOLLOW METAL
SIZE W/O JAMB
3'-0" X 6'-8" X 1 3/4 " (RH)
D3
INT/EXT FINISH
EXTERIOR PAINTED
INTERIOR
INTERIOR
HOLLOW METAL
HOLLOW METAL
3'-0" X 6'-8" X 1 3/4 " (LH)
3'-0" X 6'-8" X 1 3/4 " (RH)
PAINTED
PAINTED
WINDOW
W1
ROUGH OPENING SIZE
6'-0" X 3'-4" X 0'-7-5/8"
TYPE
LOCAL PURCHASE
NOTES
REFER TO MANUFACTURERS SPECS FOR INSTALLATOIN
SHEET 5 OF 12
T H
R E
E
R
O O
M
S
C H
O O
L
O P
E N
I N
G
S
H E
E T
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
Inst. Nac. Educ Div Los Olivos open room school
E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
SHEET 2 OF 12
T H
R E
E
R
O O
M
S
C H
O O
L
F L O
A
N
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
5 November 2017
Las Lagunas three room school
1. NOTES FOR DOORS
2. Contractor shall apply one coat of anticorrosive primer and two coats of anticorrosive paint to the door and frame.
3. Contractor shall provide commercial grade locks and hardware.
4. Contractor shall provide one master key for exterior doors and one master key for interior doors. Contractor shall provide a total of 3 key sets for schools, clinic, and latrines.
5. Door shall includes frame, handles, stopper with hook, sill, sweep, backing rod, weather strips, anchor bolts, jambs, and accessories to proper frame and door installation.
E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
D2
D1
DOOR MATERIAL
HOLLOW METAL
SIZE W/O JAMB
3'-0" X 6'-8" X 1 3/4 " (RH)
D3
INT/EXT FINISH
EXTERIOR PAINTED
INTERIOR
INTERIOR
HOLLOW METAL
HOLLOW METAL
3'-0" X 6'-8" X 1 3/4 " (LH)
3'-0" X 6'-8" X 1 3/4 " (RH)
PAINTED
PAINTED
WINDOW
W1
ROUGH OPENING SIZE
6'-0" X 3'-4" X 0'-7-5/8"
TYPE
LOCAL PURCHASE
NOTES
REFER TO MANUFACTURERS SPECS FOR INSTALLATOIN
SHEET 5 OF 12
T H
R E
E
R
O O
M
S
C H
O O
L
O P
E N
I N
G
S
H E
E T
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
Las Lagunas three room school
18'-8"
6' -8
0'-8"3'-4"1'-4"3'-4"1'-4"3'-4"1'-4"3'-4" 0'-8"
3'-8"4'-0"4'-0"3'-8"
5' -4
6'-8"
21'-4"
'-1
1"
1'-4" 1'-4"
1' -0
3'
-3
3' -0
SIDEWALK
#4 VERTICAL
REBAR &
FILLED CELL
PIT TOILET SEAT TOILET PAPER HOLDER
ROOF
OVERHANG
ROOF OVER HANG
ROOF OVERHANG
D E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
1. STRETCHER BLOCKS SHOULD BE UTILIZED UNLESS DIRECTED OTHERWISE IN THESE DRAWINGS.
2. U BLOCKS WILL BE USED IN CONTINUOUS BOND BEAMS LOCATED IN INTERIOR AND EXTERIOR WALLS. BOND BEAM LOCATIONS WILL BE THE 6th AND 15th COURSES.
3. UTILIZE CORNER BLOCKS ON ALL BUILDING CORNERS, AND IN ALL OPENINGS AS DIRECTED IN THESE DRAWINGS.
4. ABOVE OPENINGS UTILIZE U BLOCK AND REINFORCE WITH #4 REBAR TO CREATE CONCRETE LINTEL.
ANNOTATES SPECIFIC OPENING SEE OPENING SCHEDULE FOR DETAILS
DETAIL IDENTIFIER: LETTER IS DETAIL NAME NUMBER IS PAGE OF DETAIL
CMU U BLOCK USED IN BOND BEAMS
CMU CORNER BLOCK USED ON CORNERS AND OPENINGS
CMU STRETCHER BLOCK USED IN EXTERIOR AND INTERIOR WALLS
SHEET 2 OF 12
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
F O
U
A
L L
L A
T R
I N
E
F L O
A
N
5 November 2017
4 Stall Latrines total of 3 latrines:
- One at Aldea Eucalipto Zona 7
- Two at Lagunas
1. NOTES FOR DOORS
2. Contractor shall apply one coat of anticorrosive primer and two coats of anticorrosive paint to the door and frame.
3. Contractor shall provide commercial grade locks and hardware.
4. Contractor shall provide one master key for exterior doors and one master key for interior doors. Contractor shall provide a total of 3 key sets for schools, clinic, and latrines.
5. Door shall includes frame, handles, stopper with hook, sill, sweep, backing rod, weather strips, anchor bolts, jambs, and accessories to proper frame and door installation.
8' -0
0' -4
6' -8
'-0
7' -0
3'-0"
18'-8"
19'-0"
6'-8"
7'-0"
8' -0
7' -4
7' -0
1'
-6
0'-2" 0'-2"
3' -0
" M
IN
3'-0" DIA.
0' -6
10'-11"
6"
3' 2'-8" 3'
11" 1'-4"
6"
ACHIEVE 1% SLOPE TOWARD DRAIN.
2" Neopropene flashing for vent at roof penetration
GROUND LEVEL
ACHIEVE 1% SLOPE TOWARD DRAIN.
SHEET 4 OF 12
D E
S C
R I P
T I O
N
REVISIONS
DRAWN BY:
SGT Killian Simmons
APPROVED BY:
CW2 Michael Hanks
F O
U
A
L L
L A
T R
I N
E
S T
R U
C T
U R
E
E
L E
V A
T I O
N S
1s t Su rv ey a nd D es ig n
CA
MP
B
EA
UR
EG
AR
D
5 November 2017
4 Stall Latrines total of 3 latrines:
- One at Aldea Eucalipto Zona 7
- Two at Lagunas
BARS ARE EQUALLY SPACE
HORIZONTALLY AND
VERTICALLY.
WELD AT ALL BAR TO BAR CONNECTIONS AND AT BAR TO FRAME
CONNECTIONS. (TYPICAL)
WINDOW #1
LOUVER 1
WINDOW FRAME DETAILS
LOUVER 1
SECTION VIEW
12 GA. BENT STEEL PLATE
TOLERANCE: 5-15/16 + 1/16" /-0
INSIDE DIMENSION MUST BE EXACT TO GET
TIGHT FIT ON CMU WALL
1.
8" X
8" CORNER PIECE (12 GAUGE) WELDED IN ALL 4 CORNERS.
2. WELD AT ALL BAR TO BAR CONNECTIONS AND AT BAR TO FRAME CONNECTIONS. (TYPICAL)
3. VENDOR TO THE SITE COMPLETELY PRIMED ON ALL SURFACES, INSIDE AND OUTSIDE OF STEEL FRAME, AND ON ALL PIECES.
4. FABRICATED LOUVERS ARE BOLTED TOGETHER THEN INSERTED INTO METAL WINDOW AND SCREWED IN, FOUR SCREWS EACH SIDE.
5. HORIZONTAL BARS SIT 1" BACK FROM FRONT OF WINDOW.
6. WINDOW GAUGE 12 (1/8")
7. TOLERANCE + 1/16", - 0"
FRONT VIEW
8-1/4 IN
6 FT
NOT TO SCALE FOR ILLUSTARTION PURPOSE
REFER TO DOOR TECHNICAL EXHIBIT FOR
EXACT DIMENSIONS
BARS ARE EQUALLY SPACE
HORIZONTALLY AND
VERTICALLY.
WELD AT ALL BAR TO BAR CONNECTIONS AND AT BAR TO FRAME
CONNECTIONS. (TYPICAL)
WINDOW #2
WINDOW FRAME DETAILS
LOUVER 3
SECTION VIEW
12 ga. BENT STEEL PLATE
TOLERANCE: 5-15/16 + 1/16" /-0
INSIDE DIMENSION MUST BE EXACT
TO GET TIGHT FIT ON CMU WALL
NuForm LEG TO LEG WIDTH
STEEL FRAME CLEAR INSIDE WIDTH
SET OF LOUVER WINDOWS WIDTH
NuForm VERTICAL ROUGH OPG.
STEEL FRAME CLEAR INSIDE HEIGHT
LOUVER WINDOW HEIGHT
NOTES:
1.
8" X
8" CORNER PIECE (12 GAUGE) WELDED IN ALL 4 CORNERS.
2. WELD AT ALL BAR TO BAR CONNECTIONS AND AT BAR TO FRAME CONNECTIONS. (TYPICAL)
3. VENDOR TO THE SITE COMPLETELY PRIMED ON ALL SURFACES, INSIDE AND OUTSIDE OF STEEL FRAME, AND ON ALL PIECES.
4. FABRICATED LOUVERS ARE BOLTED TOGETHER THEN INSERTED INTO METAL WINDOW AND SCREWED IN, FOUR SCREWS EACH SIDE.
5. HORIZONTAL BARS SIT 1" BACK FROM FRONT OF WINDOW.
6. WINDOW GAUGE 12 (1/8" THICK BENT STEEL PLATE)
7. TOLERANCE + 1/16", - 0"
FRONT VIEW
8 1/4 in
2 ft
NOT TO SCALE FOR ILLUSTARTION PURPOSE
REFER TO DOOR TECHNICAL EXHIBIT FOR
EXACT DIMENSIONS
| BTH Clinic (70x30)-T-1 |
| BTH Clinic (70x30)-A-1 |
| BTH Clinic (70x30)-A-2 |
| BTH Clinic (70x30)-A-3 |
| BTH Clinic (70x30)-A-4 |
| BTH Clinic (70x30)-R-1 |
| BTH Clinic (70x30)-R-2 |
| BTH Clinic (70x30)-R-3 |
| BTH Clinic (70x30)-R-4 |
| BTH Clinic (70x30)-R-5 |
| BTH Clinic (70x30)-E-1 |
| BTH Clinic (70x30)-E-2 |
| BTH Clinic (70x30)-P-1 |
| BTH Clinic (70x30)-P-2 |
| BTH_19_HCA_SITE_2-SITE_PLAN.pdf |
| Sheets and Views |
| SITE_PLAN |
File details come from the government source that posted it.