A24 - Questions and Responses.pdf

PDF 73 KB Posted

Attached to
Murden Generator Procurement
Solicitation number
W912PM26QA012
Issued by

About this file

This is a Questions and Answers document for federal contract solicitation W912PM26QA012, issued on January 21, 2026. The document addresses a single inquiry regarding generator specifications for what appears to be a marine vessel application.

The response clarifies that the generator must be ABS (American Bureau of Shipping) certified rather than Lloyd's certified, per the Statement of Work specifications. The contractor is required to provide one STAMFORD Model S4L1M-F41 generator with the following specifications: Winding 25, ABS Marine Certified, SAE 1-14 rating, MX321 AVR (Automatic Voltage Regulator) with PMG (Permanent Magnet Generator), and an integrated 120V anti-condensation heater with louvres. The specification indicates marine-grade equipment suitable for vessel installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question # Question Response

Can you please confirm if this is for a vessel, and if they require Lloyds certification?

The Generator must be ABS certified per SOW Specifications. The Contractor Shall provide (1) STAMFORD Model S4L1M-F41 / Winding 25 / ABS Marine Certified / SAE 1-14 / MX321 AVR with PMG / Includes Anti Condensation Heater (120V) and Louvres.

Questions and Responses 21-Jan-26

Solicitation Number: W912PM26QA012

Sheet1

File details come from the government source that posted it. Updated .