SC-00006-16_RTA_PLANS.pdf

PDF 21 MB Posted

Attached to
SC-00006-16 Reno Bldg 1750 Federal contract opportunity
Solicitation number
W912PM-17-B-0016
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

PLANS

View the file

Other files for this federal contract opportunity

Other files attached to SC-00006-16 Reno Bldg 1750, newest first.
File Type Posted
Bid_sign_in_sheet.pdf PDF
W912PM-17-B-0016_Bid_Abstract.pdf PDF
A21)_W912PM-17-B-0016_P00003_Conformed_copy.pdf PDF
A21)_W912PM-17-B-0016_P00003_Amendment_0003.pdf PDF
3-1750_Sprinkler_Plan_-_1st_Flr.pdf PDF
3-1750_Sprinkler_Plan_-_2nd_Flr.pdf PDF
W912PM17B0016_PreBid_Site_Visit_Sign_In_Sheet.pdf PDF
W912PM17B0016-P00002.pdf PDF
W912PM17B0016-P00002_Conformed.pdf PDF
Amendment_0001_W912PM-17-B-0016.pdf PDF
SC-00006-16_RTA_CAD_DWG.zip ZIP file
ADV_SPECS_SC00006-16.pdf PDF
CazB1750HoneywellJA_KO-signed.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C O

V E

R S

H E

E T

ISSUE DATE:

of Engineers

US Army Corps

Wilmington District

J

M

IT

C H

E L L

F

IL

E N

A M

E

D R

A W

IN

G C

O D

E

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S U

B M

IT

T E

D B

Y

D A

T E

C H

E C

K E

D B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

"x

S

IZ

E

FORT BRAGG, NORTH CAROLINA

CONTRACT No.: TBD

JULY 2017

J U

L Y

J

M

IT

C H

E L L

J

M

IT

C H

E L L

J

M

IT

C H

E L L

N /A

T B

D C

O N

T R

A C

T N o

W

IL

M

IN

G T

O N

N O

R T

H C

A R

O L

IN

A

D

A R

L

IN

G T

O N A

V E

N U

E W

IL

M

IN

G T

O N D

IS

T R

IC

T U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

MODIFY FIRST AND SECOND FLOOR

BUILDING 3-1750, JSOC

SC-00006-16

IFB No.: W912PM-17-B-0016

F O

R T B

R A

G G

N O

R T

H C

A R

O L

IN

A S

C -0

-1

B

U

IL

D

IN

G -1

J S

O C

M O

D

IF

Y F

IR

S T S

E C

O N

D F

L O

O R

W P

M -1

-B -0

IF

B N o

S C -0

-1

A d v C o v e r.

d g n

G-001

GL-6

DRAWING ABBREVIATIONS INDEX OF DRAWINGS

MATERIAL LEGEND

NUMBERING SYSTEM:

A2.10/01

DISCIPLINE:

C - CIVIL

L - LANDSCAPE

A - ARCHITECTURE

M - MECHANICAL

SERIES NUMBER

A ---------------------

A/E ARCHITECT/ENGINEER

ACC ACCESSIBLE

ACS AUTOMATIC CONTROL

SYSTEM

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH

DISABILITIES ACT

ADMIN ADMINISTRATION

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ALUM ALUMINUM

APPROX APPROXIMATE

AR AS REQUIRED

ARCH ARCHITECT

ASSY ASSEMBLY

ATC ACOUSTICAL TILE CEILING

AVG AVERAGE

B ---------------------

BD BOARD

BDRY BOUNDARY

BHMA BUILDER'S HARDWARE

MANUFACTURER'S

ASSOCIATION

BLDG BUILDING

BLKG BLOCKING

BN BULLNOSE

BOS BOTTOM OF STEEL

BOT BOTTOM

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOFING

C ---------------------

CAV CAVITY

CBB CEMENTITIOUS (BACKER)

BOARD

CD CONSTRUCTION

DOCUMENTS

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED

/CONTRACTOR INSTALLED

CFE CONTRACTOR FURNISHED

EQUIPMENT

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL

FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLRM CLASSROOM

CMU CONCRETE MASONRY UNIT

CDR CARD READER

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

COORD COORDINATE

CORR CORRIDOR

CPT CARPET

CT CERAMIC TILE

CTR CENTER

CU FT CUBIC FEET

D ---------------------

D DEPTH

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

E ---------------------

EA EACH

EIFS EXTERIOR INSULATION

AND FINISH SYSTEM

EJ EXPANSION JOINT

ES EACH SIDE

EL ELEVATION

ELEV ELEVATOR

ENTR ENTRANCE

EQ EQUAL

EWC ELECTRIC WATER COOLER

EXP EXPOSED

EXT EXTERIOR

EXT EXTINGUISHER

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR

PANEL

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER

CABINET

FF EL FINISH FLOOR ELEVATION

FGL FIBERGLASS

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLG FLOORING

FLR FLOOR

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FR FIRE RESISTANT

FRG FIBER REINFORCED

GYPSUM

FRMG FRAMING

FRP FIBERGLASS REINFORCED

PLASTIC

FRTW FIRE RETARDANT TREATED

WOOD

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET

FTG FOOTING

FWC FABRIC WALLCOVERING

G ---------------------

G NATURAL GAS

GA GAGE/GUAGE

GALV GALVANIZED

GB GRAB BAR

GFCI GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GFGI GOVERNMENT INSTALLED

FURNISHED INSTALLED BY

GOVERNMENT

GFRG GLASS-FIBER-REINFORCED

GYPSUM

GLZ GLAZING

GUT GUTTER

GYP BD GYPSUM BOARD

H ---------------------

HB HOSE BIBB

HDPE HIGH DENSITY

POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY

PARTICULATE AIR (FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HORIZ HORIZONTAL

HT HEIGHT

HYDR HYDRAULIC

I ---------------------

IBC INTERNATIONAL BUILDING

CODE

INSUL INSULATION

INT INTERIOR

ILO IN LIEU OF

J ---------------------

JAN JANITOR

K ---------------------

KPD KEYPAD

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAM LAMINATE

LAV LAVATORY

LBS POUND

LIB LIBRARY

LIN LINEAR

LOC LOCATION

LT LIGHT

LVR LOUVER

M ---------------------

MACH RM MACHINE ROOM

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MFR MANUFACTURER

MIL STD MILITARY STANDARD

MIN MINIMUM, MINUTE

MISC MISCELLANEOUS

MO MASONRY OPENING

MOD MODIFY

MTG MOUNTING

MTL METAL

MWP MEMBRANE

WATERPROOFING

T --------------------

T TREAD

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO

THK THICKNESS

TN TRUE NORTH

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF SLAB

E - ELECTRICAL

P - PLUMBING

S - STRUCTURAL

K - FOOD SERVICE

SHEET NUMBER WITHIN SERIES

NUMBER OF PLAN, DETAIL, ETC. ON

SHEET

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE

PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O -------------------

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OFF OFFICE

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OWSJ OPEN WEB STEEL JOIS

ORIG ORIGINAL

P --------------------

PA PUBLIC ADDRESS

PB PULL BOX

PBD PARTICLEBOARD

PCC PRECAST CONCRETE

PCF POUNDS PER CUBIC FT

PERF PERFORATED

PERIM PERIMETER

PH PHASE

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PNL PANEL

PP PL PUSH/PULL PLATE

PR PAIR

PRCST PRECAST

PRKG PARKING

PSF POUNDS PER SQUARE

FOOT

PSI POUNDS PER SQUARE

INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER

AND RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTY QUANTITY

R --------------------

RB RESILIENT BASE

RBR RUBBER

RC REINFORCED CONCRETE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFERENCE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

REST RESTROOM

RF RESILIENT FLOORING

RFG ROOFING

RH ROOF HATCH

RHR RIGHT HAND REVERSE

RM ROOM

RO ROUGH OPENING

RV ROOF VENT

RVL REVEAL

S --------------------

SB SPLASH BLOCK

SCHED SCHEDULE

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SGL SINGLE

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SL SLOPE

SLNT SEALANT

SMK SMOKE

SMLS SEAMLESS

SP EL SPOT ELEVATION

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SST STAINLESS STEEL

STD STANDARD

STL JST STEEL JOIST

STOR STORAGE

STRB/HRN STROBE/HORN

ACCESSORY BY MARK

12345X

Name

Elevation

ROOM NAME

150 SF

A202

SIM

1t

NORTH ARROW

SQUARE FOOTAGE

ROOM NUMBER

ROOM NAME

VIEW NUMBER

VIEW NAME

VIEW SCALE

WALL TAG

WINDOW TAG

DOOR TAG

LEVEL

MARK

SHEET NUMBER

SIMILAR TAG

DETAIL LOCATED ON SHEET (MAY ALSO BE

REF. UNDER TITLE FOR MULTIPLE SHEETS)

SIMILAR TAG

ELEVATION RELATIVE TO FIRST

FLOOR FIN. FLR.

FLOOR/LEVEL NAME

BUILDING SECTION

99 SIM

RE101 A103

99 SIM

AE101

DETAIL CALL-FROM SHEET

(IF USED)

VIEW NUMBER

SHEET NUMBER

SIMILAR TAG

PLAN

NORTH N

TRUE NORTH -56.247

DEGREE FROM PLAN

NORTH

PLAN NORTH INDICATOR

TRUE NORTH

MATCHLINE 11/ AE-101.A1

MATCH LINE

NUMBER ON

MATCHING SHEET

CONTINUATION SHEET

NOTE: 'CALL-FROM' REFERENCES ONLY REFER TO

ORIGINAL CALLOUT, 'SIM' CONDITIONS ARE NOT INCLUDED

DETAIL LOCATED

ON SHEET

AE101

A

VIEW IDENTIFIER

FURNITURE/EQUIP.

BY MARK

ROOM TAG WITH SQUARE FOOTAGES*

DETAIL CALLOUT

CALLOUT - DETAILS (BACK REFERENCES)

ELEVATION

MATCH LINE

VIEW TITLE

SIM

SIMILAR TAG

SIM

B

A202

SIM

A202

SIM

______________VIEW NUMBER

SHEET NUMBER

SIMILAR TAG

WALL SECTION

99 SIM

AE101

VIEW NUMBER

SHEET NUMBER

SIMILAR TAG

DETAIL CALLOUT

GRID HEAD

FINISH EXTENTS

VIEW NUMBER

SHEET NUMBER

SIMILAR TAG

BUILDING ELEVATION

VIEW NUMBER

XXXXX

999Z

DEMOLITION NOTE

XXXSPECIALTY EQUIP.

TARGET "AFF FIRST FLOOR"

"TARGET"

SPOT ELEVATION W/

REF TO FIN. FLR.

FINISH ID

Name

Elevation

EXTENT OF DETAIL

KEYED NOTE

RENOVATION NOTE

REVISION NOTE

C

D

0'-0"

FIN. FLR.

EARTH - COMPACTED

FILL

CONCRETE

BRICK - MASONRY

STEEL

PLYWOOD

RIGID INSULATION

BATT INSULATIONFINISHED WOOD

BLOCKING

CONTINUOUS WOOD

CONCRETE MASONRY

UNIT (PLAN)

CONCRETE MASONRY

UNIT (SECTION)

GLASS MAT

SHEATHING

SPRAY-FOAM

INSULATION

SAND, FIREPROOFING,

MORTAR, GROUT,

PLASTER, DRYWALL

ARCHITECTURAL SYMBOLS LEGEND

A202

SIM

PREFORMED SEALANT

8A

AE103 3/32" = 1'-0"RE101

VIEW NAMEVIEW REFERENCE

VIEW NUMBER

TILT WALL PANEL TAG 8A

C E

N T

E R

O F

L E

V E

R

MORTISE LOCK

MOUNTING HEIGHT

C E

N T

E R

O F

P A

N

IC

B A

R

PANIC BAR

MOUNTING HEIGHT

PUSH PULL

MOUNTING HEIGHT

COAT HOOK

MOUNTING HEIGHT

CENTER LINE

OF DOOR

COAT HOOK

'-3

'-3

/4

'-6

'-0

S

T A

N D

A R

D

'-0

A

D A

FIRE

EXTINGUISHER

CABINET

FIRE

VALVE/

FIRE HOSE

CABINET

ELECTRICAL/

COMMUNICATIONS

PANEL

BOARD

FIRE

DETECTION

PANEL

AUDIBLE

FIRE

ALARM &

STROBE

ACCESS

DOOR

C .L

H

A N

D L E

'-0

C .L

H

A N

D L E

'-0

" 6 '-0

'-0

'-2

" 6 '-8

X

NOTE: Y=48"

MIN IF DOOR

HAS A CLOSERNOTE:

X=12" IF

DOOR HAS

BOTH A

CLOSER AND

A LATCH.

NOTE: X=36" MIN IF Y=60"

NOTE: X=42" MIN IF Y=54"

NOTE: Y=48"

MIN IF DOOR

HAS BOTH A

CLOSER AND

A LATCH.

NOTE: Y=54" MIN

IF DOOR HAS CLOSER

'-0

1'-6" (24" PREFERRED)

X

'-6

Y

'-6

4'-6"

Y

'-6

2'-0"

X

1'-2"

'-6

Y

'-0

2'-0"

GENERAL NOTES

1. THE OBJECTIVE OF THIS SHEET IS TO ESTABLISH

GUIDELINES FOR THE VERTICAL LOCATION OF

ITEMS AND DEVICES THROUGHOUT THE

PROJECT.

A. COORDINATE THESE DIMENSIONS WITH

APPLICABLE CODES AND MANUFACTURER

STANDARDS. PER GOVERNMENT STATED

REQUIREMENTS, THIS FACILITY WILL BE

PRIMARILY UTILIZED BY ABLE BODIED

WORKERS, ADA ACCESS IS NOT REQUIRED.

B. IN ALL CASES, THE MORE STRINGENT

STATUTES AND CODES APPLY.

2. ITEMS ILLUSTRATED ON THIS SHEET ARE

REPRESENTATIVE OF CONDITIONS THAT MAY

OCCUR IN THE SCOPE OF THE PROJECT.

WEIGHTS AND OTHER INFORMATION SHOWN ARE

TYPICAL AND SHALL BE APPLIED THROUGHOUT

THE PROJECT.

3. ADDITIONAL MOUNTING HEIGHTS AND RELATED

INFORMATION IS SHOWN ON DRAWINGS OR AS

SPECIFIED.

4. PROVIDE BLOCKING AS NECESSARY.

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

GI002

K M

B L E

G E

N D

S A

B B

R E

V

IA

T

IO

N S

G E

N E

R A

L N

O T

E S

A

N D

T Y

P

IC

A L

M O

U N

T I N

G H

E

IG

H T

S

G I0

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

1/4" = 1'-0"GI002

1 DOOR HARDWARE MOUNT HEIGHTS

1/4" = 1'-0"GI002

2 DOD-PANEL MOUNTING HEIGHTS

1/4" = 1'-0"GI002

3 ADA-CLEARANCES FOR DOORS WITH CLOSERS & LATCHES

0" 2'-0" 4'-0" 8'-0"

1/4"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

06/09/2017

UP

FEC

FEC

219 SF

OFFICE

59 SF

STORAGE

360 SF

WORK SPACE

509 SF

OFFICE/ STUDIO

855 SF

OPEN OFFICE

176 SF

WORK SPACE

637 SF

GENERAL STORAGE

109 SF

VESTIBULE

102A

426 SF

FOYER

STAIR 1

424 SF

CONFERENCE

247 SF

STORAGE

190 SF

STORAGE

UPS

290 SF

MECHANICAL

104 SF

COMM ROOM

113 SF

WOMEN

173 SF

MEN

25 SF

JANITOR

STAIR 2

92 SF

SHOWERS

D

IS

TA

N

C E T

O E

G R E S S

D

IS

C H

A R G

E

8'

D

IS

T A

N C

E T

O E

G R

E S

S

D

IS

C H

A R

G E

' 0

DISTANCE TO EGRESS

DISCHARGE - 46' 2"

72 SF

STORAGE

92 SF

ELEVATOR EQUIPMENT

104A

Codes

UFC 3-600-01 Fire Protection Engineering For Facilities

UFC 4-021-01 Design And O&M: Mass Notification Systems

National Fire Protection Assoc. NFPA 13, 24, 101

International Building Code 2015

Building Code Evaluation

Occupancy

Storage Group - Group S-1, Moderate Hazard, Most Restrictive - Raw Stock (311)

Business Group - Group B, Business - Offices, Control Room and Training Rooms (304)

Construction Type IIB (Chapter 6)

Fire Resistive of Building Elements (Table 601)

Structural Frame: 0-Hour

Exterior Bearing Walls: 0-Hour

Interior Bearing Walls: 0-Hour

Floor Construction: 0-Hours

Greater Than 30 ft: 0-Hour

Exterior Wall Fire Resistance For Separation:

Less Than 5 ft 2-Hour

Between 5 ft and 10 ft 1-Hour

Between 10 ft and 30 ft 0-Hour

Greater Than 30 ft 0 -Hour

Allowable Height (Table 503): 2 Stories

Allowable Area (Table 503): 15,500 sf

Area Increase with Sprinklers: 300% (506.1)

Allowable Area with Sprinklers: 62,000 sf

Actual Area: First Floor = 6,845 sf

Second Floor = 7,645.50 sf

Total Area = 14,490.50 sf

Egress arrangement, interior finish, and exit capacity is based on NFPA 101, Life Safety Code.

Life Safety Code Evaluation

Occupancy:

Mixed With Separation

Chapter 39, Existing Business Occupancies

Chapter 42, Storage Occupancies

Classification of hazards of contents (40.1.5): Ordinary

Minimum Construction Requirements (40.1.6): None

Egress Capacity (40.2.3) and Number of Exits (40.2.4):

3 Doors @ 33" clear = 99 inches

1 Door @ 45" clear = 45 inches

144/0.2 inches per occupant = 720 occupants

Egress Arrangement (40.2.5) With Sprinkler System:

Dead End Corridor (Table 40.2.5): 50ft

Common Path of Travel (Table 40.2.5): 100ft

Travel Distance (40.2.6): 250ft

Exit Lighting (40.2.10): Provided

Protection of Vertical Openings (40.3): Shafts and stairs will be 1Hr rated

Protection from Hazards (40.3.2): No explosion hazards, complete sprinkler system.

Rated Barriers: Required and indicated.

Detection, Alarm and Communication (40.3.4): Fire Alarm system provided per

NFPA 72

Extinguishment (40.3.5): Complete Sprinkler Protection System Provided

Corridors (40.3.6): No Requirements

Occupant Load (40.1.7):

Occupancy Area Area Occupant Occupant

Classification Use Size (sf) Load Factor Load

(sf/Occupant) (Occupants)

Storage Storage 104 758 300 3

Storage 105 59.23 300 1

Storage (UPS) 189.88 300 1

Storage 116 246.71 300 1

Business Work Space 103 360.44 100 4

Office/Studio 102 508.57 100 6

Office 106 219.49 100 3

Open Office 110 855 100 9

Conference Room 118 423.99 100 5

Training Room 1st 1528 100 16

Training Room 2nd 1528 100 16

Conference Room 205 377.59 100 4

Open Office 206 645.82 100 7

Office 209 289.15 100 3

Office 208 233.13 100 3

Office 204 101.42 100 2

Work Space 213 246.65 100 3

Work Space 203 1766.42 100 18

Work Space 202 462.20 100 5

Work Space 212 595.90 100 6

Work Space 211 529.74 100 6

Break Room 210 142.22 100 2

Not Normally Comm Room 109 103.70 N/A N/A

Occupied Men Restroom 113 173.40 N/A N/A

Women Restroom 114 112.69 N/A N/A

Showers 121 91.53 N/A N/A

Mechanical 115 289.97 N/A N/A

Janitor 111 24.66 N/A N/A

Electrical Room 206A 64.19 N/A N/A

Men 207 166.69 N/A N/A

Total Occupants 101

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

ONE HOUR FIRE RATED WALL

SEMI-RECESSED FIRE

EXTINGUISHER CABINET

FEC

EXIT SIGN

TRAVEL PATH

GENERAL NOTES

1. PER THE GOVERNMENT ISSUED

SCOPE OF WORK, THIS FACILITY WILL

BE PRIMARILY UTILIZED BY ABLE

BODIED WORKER, ADA ACCESS IS

NOT REQUIRED

S1 STAIR

D1 EXIT DOOR

S2 STAIR

39" STAIR

7" RISE, 11" RUN

130 PERSONS MAX.

(0.3" PER OCCUPANT)

ACTUAL 62

(1) 36" DOOR

32" CLEAR OPENING

WIDTH

160 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 62

39" STAIR

7" RISE, 11" RUN

130 PERSONS MAX.

(0.3" PER OCCUPANT)

ACTUAL 62

NOTE: GOVERNMENT TO CONFIRM ALL 1HR RATED

WALLS INDICATED ON THE LIFE SAFETY SHEETS LS101

AND LS102 ARE INDEED 1HR RATED. CONTRACTOR TO

REPAIR ANY DAMAGED WALLS AND MAINTAIN ALL

RATED WALL ASSEMBLIES DURING CONSTRUCTION.

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

LS101

K M

B F

IR

S

T F

L O

O R

P A

R T

IA

L L

IF

E

S A

F E

T Y

P L A

N

L S

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"LS101

1 FIRST FLOOR PARTIAL LIFE SAFETY PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

D1 S2

D1 S1 D1

D1

M A

R K

D E

S C

R

IP

T

IO

N D

A T

DN

FEC

FEC

FEC

1766 SF

WORK SPACE

247 SF

WORK SPACE

101 SF

OFFICE

378 SF

CONFERENCE ROOM

646 SF

OPEN OFFICE

64 SF

ELECTRICAL ROOM

206A

289 SF

OFFICE

233 SF

OFFICE

167 SF

MEN

STAIR 1

462 SF

WORK SPACE

141 SF

BREAK ROOM

494 SF

HALL

530 SF

WORK SPACE

596 SF

WORK SPACE

STAIR 2

1" / 12"

3 1/2"

3 1/2"

206A

DISTANCE TO EGRESS

DISCHARGE - 99' 0"

DISTANCE TO EGRESS

DISCHARGE - 88' 0"

D1 S2

3 1/2"

D1 S1

EXISTING LEVEL 2 3/4" WALL TO REMAIN AS IS. ALL

INFRASTRUCTURE WILL BE

SURFACES MOUNTED.

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

ONE HOUR FIRE RATED WALL

SEMI-RECESSED FIRE

EXTINGUISHER CABINET

FEC

EXIT SIGN

TRAVEL PATH

GENERAL NOTES

1. PER THE GOVERNMENT ISSUED

SCOPE OF WORK, THIS FACILITY WILL

BE PRIMARILY UTILIZED BY ABLE

BODIED WORKER, ADA ACCESS IS

NOT REQUIRED

S1 STAIR

D1 EXIT DOOR

S2 STAIR

39" STAIR

7" RISE, 11" RUN

130 PERSONS MAX.

(0.3" PER OCCUPANT)

ACTUAL 62

(1) 36" DOOR

32" CLEAR OPENING

WIDTH

160 PERSONS MAX.

(0.2" PER OCCUPANT)

ACTUAL 62

39" STAIR

7" RISE, 11" RUN

130 PERSONS MAX.

(0.3" PER OCCUPANT)

ACTUAL 62

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

LS102

K M

B S

E C

O N

D F

L O

O R

P A

R T

IA

L L

IF

E

S A

F E

T Y

P L A

N

L S

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"LS102

1 SECOND FLOOR PARTIAL LIFE SAFETY PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

WORK SPACE

WORK SPACE

OFFICE/ STUDIO

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

3' - 4" 4"

8" 3' - 4"

/4

1' - 0" 4' - 9"

AD301

AD301

AD301

AD301

STORAGE

ELEVATOR EQUIPMENT

01 DEMOLISH REVOLVING DOOR

DEMOLITION NOTES

02 DEMOLISH WALL FOR NEW DOOR

03 DEMOLISH INTERIOR PARTITION

04 DEMOLISH DOOR AND FRAME

05 REMOVE SINK

06 PARTITIONS TO REMAIN, PATCH AS REQUIRED

07 EXISTING FINISHES AND LIGHTING TO REMAIN, PATCH AS REQUIRED

08 PROPOSED CONTRACTOR ENTRANCE DURING DEMO AND CONSTRUCTION

09 REMOVE COOLER

10 TRENCH DRAIN GRATES TO BE REMOVED

CAREFULLY REMOVE, PROTECT AND STORE EXISTING ACOUSTIC CEILING TILE

AND GRID FOR POSSIBLE REUSE OR DEMOLISH EXISTING GYPSUM BOARD

CEILING AFFECTED BY MECHANICAL DEMOLITION

12 3 1/2" ACCESS FLOOR TO REMAIN

13 RAMP TO REMAIN

14 FIRE RISER

EXISTING ACOUSTIC CEILING TILE TO REMAIN, VERIFY HEIGHT IN FIELD;

COORDINATE CEILING REMOVAL/ REPLACEMENT IN PORTIONS OF ROOMS 203

TO ACCOMODATE HVAC WORK. SEE SHEET MD102 AND MH102

16 EXISTING TRENCH TO REMAIN

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

DEMOLITION GENERAL NOTES

1. PROVIDE/ ACQUIRE ALL PERMITS NECESSARY FOR HAZARDOUS

MATERIALS ABATEMENT AND DISPOSAL WHERE APPLICABLE.

2. REMOVE AND SALVAGE UNLESS OTHERWISE NOTED, ALL FIRE

EXTINGUISHERS, FIRE ALARM SYSTEM, AND OTHER EQUIPMENT AS

INDICATED BY CONTRACTING OFFICER. COORDINATE WITH THE

REPRESENTATIVES ANY ADDITIONAL EQUIPMENT TO BE SALVAGED &

THE PROPER STORAGE FOR SALVAGED EQUIPMENT.

3. REMOVE AND DISPOSE U.O.N., ALL DOORS AND FRAMES.

4. NOTIFY CONTRACTING OFFICER REPRESENTATIVE (COR) OF ALL

DISCREPANCIES THAT AFFECT OTHER TRADES NOT TO BE

DEMOLISHED. COORDINATE ALL DEMOLITION WORKS WITH

MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, TELECOM,

DATA, CATV AND PA SYSTEMS.

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AD101

K M

B F

IR

S

T F

L O

O R

P A

R T

IA

L

D E

M O

L

IT

IO

N

P L A

N

A D

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AD101

1 FIRST FLOOR PARTIAL DEMOLITION PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

WORK SPACE

WORK SPACE

206 209

03 04

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

0"

0"

0"

3 1/2"

3 1/2"

/ 1

1" / 12"

7' - 10" 3' - 8" 3' - 4" 5' - 2"

AD301

AD301

AD301

AD301

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

01 DEMOLISH REVOLVING DOOR

DEMOLITION NOTES

02 DEMOLISH WALL FOR NEW DOOR

03 DEMOLISH INTERIOR PARTITION

04 DEMOLISH DOOR AND FRAME

05 REMOVE SINK

06 PARTITIONS TO REMAIN, PATCH AS REQUIRED

07 EXISTING FINISHES AND LIGHTING TO REMAIN, PATCH AS REQUIRED

08 PROPOSED CONTRACTOR ENTRANCE DURING DEMO AND CONSTRUCTION

09 REMOVE COOLER

10 TRENCH DRAIN GRATES TO BE REMOVED

CAREFULLY REMOVE, PROTECT AND STORE EXISTING ACOUSTIC CEILING TILE

AND GRID FOR POSSIBLE REUSE OR DEMOLISH EXISTING GYPSUM BOARD

CEILING AFFECTED BY MECHANICAL DEMOLITION

12 3 1/2" ACCESS FLOOR TO REMAIN

13 RAMP TO REMAIN

14 FIRE RISER

EXISTING ACOUSTIC CEILING TILE TO REMAIN, VERIFY HEIGHT IN FIELD;

COORDINATE CEILING REMOVAL/ REPLACEMENT IN PORTIONS OF ROOMS 203

TO ACCOMODATE HVAC WORK. SEE SHEET MD102 AND MH102

16 EXISTING TRENCH TO REMAIN

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AD102

K M

B S

E C

O N

D F

L O

O R

P A

R T

IA

L

D E

M O

L

IT

IO

N

P L A

N

A D

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AD102

1 SECOND FLOOR PARTIAL DEMOLITION PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

WORK SPACE

OFFICE/ STUDIO

WORK SPACE

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

9' - 10"

9' - 0"

10' - 6"

10' - 6"

15 15

AD301

AD301

AD301

AD301

STORAGE

ELEVATOR EQUIPMENT

NEW ACOUSTIC CEILING TILE

DEMOLISH GYPSUM BOARD

AREA NOT IN CONTRACT

RCP LEGEND

EXISTING ACOUSTIC

CEILING TILE TO REMAIN

DEMOLISH ACOUSTIC

CEILING TILE

CEILING ELEVATION AFF

0' 0"

1X4 LIGHT FIXTURE

2X2 LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR DIFFUSER

RECESSED DOWN LIGHT

01 DEMOLISH REVOLVING DOOR

DEMOLITION NOTES

02 DEMOLISH WALL FOR NEW DOOR

03 DEMOLISH INTERIOR PARTITION

04 DEMOLISH DOOR AND FRAME

05 REMOVE SINK

06 PARTITIONS TO REMAIN, PATCH AS REQUIRED

07 EXISTING FINISHES AND LIGHTING TO REMAIN, PATCH AS REQUIRED

08 PROPOSED CONTRACTOR ENTRANCE DURING DEMO AND CONSTRUCTION

09 REMOVE COOLER

10 TRENCH DRAIN GRATES TO BE REMOVED

CAREFULLY REMOVE, PROTECT AND STORE EXISTING ACOUSTIC CEILING TILE

AND GRID FOR POSSIBLE REUSE OR DEMOLISH EXISTING GYPSUM BOARD

CEILING AFFECTED BY MECHANICAL DEMOLITION

12 3 1/2" ACCESS FLOOR TO REMAIN

13 RAMP TO REMAIN

14 FIRE RISER

EXISTING ACOUSTIC CEILING TILE TO REMAIN, VERIFY HEIGHT IN FIELD;

COORDINATE CEILING REMOVAL/ REPLACEMENT IN PORTIONS OF ROOMS 203

TO ACCOMODATE HVAC WORK. SEE SHEET MD102 AND MH102

16 EXISTING TRENCH TO REMAIN

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AD103

K M

B F

I R S

T F

L O

O R

R E

F L E

C T

E D

C E

IL

IN

G D

E M

O L

IT

IO

N

P L A

N

A D

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AD103

1 FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

WORK SPACE

WORK SPACE

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

8' - 6"

8' - 6"

8' - 11"

7' - 10"

AD301

AD301

AD301

AD301

NEW ACOUSTIC CEILING TILE

DEMOLISH GYPSUM BOARD

AREA NOT IN CONTRACT

RCP LEGEND

EXISTING ACOUSTIC

CEILING TILE TO REMAIN

DEMOLISH ACOUSTIC

CEILING TILE

CEILING ELEVATION AFF

0' 0"

1X4 LIGHT FIXTURE

2X2 LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR DIFFUSER

RECESSED DOWN LIGHT

01 DEMOLISH REVOLVING DOOR

DEMOLITION NOTES

02 DEMOLISH WALL FOR NEW DOOR

03 DEMOLISH INTERIOR PARTITION

04 DEMOLISH DOOR AND FRAME

05 REMOVE SINK

06 PARTITIONS TO REMAIN, PATCH AS REQUIRED

07 EXISTING FINISHES AND LIGHTING TO REMAIN, PATCH AS REQUIRED

08 PROPOSED CONTRACTOR ENTRANCE DURING DEMO AND CONSTRUCTION

09 REMOVE COOLER

10 TRENCH DRAIN GRATES TO BE REMOVED

CAREFULLY REMOVE, PROTECT AND STORE EXISTING ACOUSTIC CEILING TILE

AND GRID FOR POSSIBLE REUSE OR DEMOLISH EXISTING GYPSUM BOARD

CEILING AFFECTED BY MECHANICAL DEMOLITION

12 3 1/2" ACCESS FLOOR TO REMAIN

13 RAMP TO REMAIN

14 FIRE RISER

EXISTING ACOUSTIC CEILING TILE TO REMAIN, VERIFY HEIGHT IN FIELD;

COORDINATE CEILING REMOVAL/ REPLACEMENT IN PORTIONS OF ROOMS 203

TO ACCOMODATE HVAC WORK. SEE SHEET MD102 AND MH102

16 EXISTING TRENCH TO REMAIN

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AD104

K M

B S

E C

O N

D F

L O

O R

R E

F L E

C T

E D

C E

IL

IN

G D

E M

O L

IT

IO

N

P L A

N

A D

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AD104

1 SECOND FLOOR REFLECTED CEILING DEMOLITION PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

LEVEL 1

0"

LEVEL 2

15' - 5 5/128"

LEVEL 3

30' - 10 5/64"

106104

205206

FOYER

STORAGE

MECHANICAL

COMM ROOM

WOMEN

OFFICE

HALL

WORK SPACE

AD301

AD301

04 05

03 0306

LEVEL 1

0"

LEVEL 2

15' - 5 5/128"

LEVEL 3

30' - 10 5/64"

AD301

AD301

103 110 104

203 205

01 0402

3' - 4"

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

01 DEMOLISH REVOLVING DOOR

DEMOLITION NOTES

02 DEMOLISH WALL FOR NEW DOOR

03 DEMOLISH INTERIOR PARTITION

04 DEMOLISH DOOR AND FRAME

05 REMOVE SINK

06 PARTITIONS TO REMAIN, PATCH AS REQUIRED

07 NOT USED

08 NOT USED

09 NOT USED

10 NOT USED

CAREFULLY REMOVE, PROTECT AND STORE EXISTING ACOUSTIC CEILING TILE

AND GRID FOR POSSIBLE REUSE OR DEMOLISH EXISTING GYPSUM BOARD

CEILING AFFECTED BY MECHANICAL DEMOLITION

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AD301

K M

B B

U

IL

D

IN

G S

E C

T I O

N

D E

M O

L

IT

IO

N

A D

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AD301

2 BUILDING SECTION DEMOLITION

3/16" = 1'-0"AD301

1 BUILDING SECTION DEMOLITION

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

OFFICE

STORAGE

WORK SPACE

OFFICE/ STUDIO

OPEN OFFICE

WORK SPACE

GENERAL STORAGE

VESTIBULE

102A

/8

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

8" 3' - 4" 12' - 3 5/8" 5' - 0" 31' - 4 3/4" 1' - 2 1/8" 3' - 4" 11' - 6 1/4"

/4

/2

/8

/4

03 03

1' - 0" 12' - 4" 1' - 0"

3 44

2A

2A

AE301

AE301

AE301

AE301

43 1/2"

3 1/2"

3 1/2" 0"

AE701

Sim

STORAGE

ELEVATOR EQUIPMENT

ALIGN

A L

IG

N

CARD

READER

104A

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

FLOOR PLAN NOTES

01 INSULATE EXISTING WALL TO MEET STC 45, REPAIR AS NEEDED

INFILL EXISTING RECESSED COOLER SLAB WITH CONCRETE FILL TO MATCH

EXISTING FLOOR LEVEL

INFILL EXISTING RECESSED TRENCH DRAIN WITH CONCRETE FILL TO MATCH

EXISTING FLOOR LEVEL

04 EXISTING ACCESS FLOOR

REPAIR WALL AS NEEDED WITH 5/8" GYPSUM BOARD FROM FLOOR TO CEILING

AS NEEDED

06 NEW LOW PROFILE ACCESS FLOOR

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE101

K M

B F

IR

S

T F

L O

O R

P A

R T

IA

L

P R

O P

O S

E D

P L A

N

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AE101

1 FIRST FLOOR PARTIAL PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

FEC

WORK SPACE

WORK SPACE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

206A

OFFICE

1" / 12"

3 1/2"

3 1/2"

3 1/2"

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

0"

0"

3 1/2"

3 1/2" 1" / 12"

/ 1

1" / 12"

9' - 10" 6' - 6 5/8" 3' - 4" 8" 30' - 9 5/8" 10" 3' - 4" 2' - 2 1/4"

/8

/2

3 3

2B

2B

AE301

AE301

AE301

AE301

0"

0"

AE701

Sim

AE701

Sim

ALIGN

3 1/2"

2 3/4"

3/4" DROP

VERIFY

2B

EXTEND EXISTING WALL TO DECK

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

FLOOR PLAN NOTES

01 INSULATE EXISTING WALL TO MEET STC 45, REPAIR AS NEEDED

INFILL EXISTING RECESSED COOLER SLAB WITH CONCRETE FILL TO MATCH

EXISTING FLOOR LEVEL

INFILL EXISTING RECESSED TRENCH DRAIN WITH CONCRETE FILL TO MATCH

EXISTING FLOOR LEVEL

04 EXISTING ACCESS FLOOR

REPAIR WALL AS NEEDED WITH 5/8" GYPSUM BOARD FROM FLOOR TO CEILING

AS NEEDED

06 NEW LOW PROFILE ACCESS FLOOR

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE102

K M

B S

E C

O N

D F

L O

O R

P A

R T

IA

L

P R

O P

O S

E D

P L A

N

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AE102

1 SECOND FLOOR PARTIAL PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC FEC

OFFICE

STORAGE

WORK SPACE

OFFICE/ STUDIO

OPEN OFFICE

GENERAL STORAGE

VESTIBULE

102A

FOYER

STAIR 1

CONFERENCE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

10' - 0"

10' - 0"

10' - 0"

9' - 0"

AE301

AE301

AE301

AE301

OPEN TO ABOVE

STORAGE

ELEVATOR EQUIPMENT

EQ EQ

E Q

E Q

NEW ACOUSTIC CEILING TILE

DEMOLISH GYPSUM BOARD

AREA NOT IN CONTRACT

RCP LEGEND

EXISTING ACOUSTIC

CEILING TILE TO REMAIN

DEMOLISH ACOUSTIC

CEILING TILE

CEILING ELEVATION AFF

0' 0"

1X4 LIGHT FIXTURE

2X2 LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR DIFFUSER

RECESSED DOWN LIGHT

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE103

K M

B F

I R S

T F

L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AE103

1 FIRST FLOOR REFLECTED CEILING PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

WORK SPACE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

OFFICE

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

OPEN TO

ABOVE

9' - 0"

10' - 0"

10' - 0"

10' - 0"

AE301

AE301

AE301

AE301

E Q

E Q

EQ EQ

E Q

E Q

EQ EQ

NEW ACOUSTIC CEILING TILE

DEMOLISH GYPSUM BOARD

AREA NOT IN CONTRACT

RCP LEGEND

EXISTING ACOUSTIC

CEILING TILE TO REMAIN

DEMOLISH ACOUSTIC

CEILING TILE

CEILING ELEVATION AFF

0' 0"

1X4 LIGHT FIXTURE

2X2 LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR DIFFUSER

RECESSED DOWN LIGHT

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE104

K M

B S

E C

O N

D F

L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AE104

1 SECOND FLOOR REFLECTED CEILING PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

LEVEL 1

0"

LEVEL 2

15' - 5 5/128"

LEVEL 3

30' - 10 5/64"

AE301

AE301

WORK SPACE

OPEN OFFICE

GENERAL STORAGE

WORK SPACE

CONFERENCE ROOM

LEVEL 1

0"

LEVEL 2

15' - 5 5/128"

LEVEL 3

30' - 10 5/64"

GENERAL STORAGE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

OFFICE

FOYER

STORAGE

MECHANICAL

COMM ROOM

WOMEN

HALL

WORK SPACE

AE301

AE301

OFFICE

AREA NOT IN CONTRACT

LEGEND

EXISTING TO REMAIN

DEMOLITION

NEW CONSTRUCTION

ACCESS FLOOR

SPOT ELEVATION AFF

0' 0"

1A PARTITION TYPES, SEE AE701

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE301

K M

B B

U I L

D

IN

G S

E C

T

IO

N S

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AE301

1 BUILDING SECTION

3/16" = 1'-0"AE301

2 BUILDING SECTION

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

HM1

R

.O

HOLLOW METAL FRAMES

3' - 4"

HM3

R .O

5' - 4"

HM4

R

.O

4' - 4"

HM5

R

.O

4' - 4"

FINISH

FLOOR

AL1

R

.O

6' - 4"

HM2

R

.O

3' - 4"

ALUMINUM FRAMES

"F"

SINGLE SWING

DOOR

"F1"

DOUBLE ONE WAY

SWING DOOR

"S"

DOUBLE SLIDING

GLASS DOOR

6' - 0"

MIN.

3' - 0"

GL1 GL1

GENERAL NOTES:

ACOU = ACOUSTIC

AL = ALUMINUM

ANOD = ANODIZED

ORG = ORGANIC

STL = STEEL

SC = SOLID CORE WOOD

HM = HOLLOW METAL

FPG = FIRE PROTECTIVE GLAZING

ATFP = ANTI TERRORISM / FORCE PROTECTION

STD = STD. DUTY

HD = HVY. DUTY

XHD = EXTRA HVY. DUTY

MD = MAX DUTY

IGU = INSULATED GLASS UNIT

LAM = LAMINATED

WD = WOOD

PT = PAINT COLOR

SMK = SMOKE RATED

ST = STAIN COLOR

STC = SOUND TRANSMISSION COEFFICIENT

PB = PANIC BAR

TEMP = TEMPERED

MG = METAL GATE

GL1 = TEMPERED CLEAR

LEGEND:

REMARKS:

1. REFER TO SHEET AE607-AE610 FOR DOOR DETAILS.

2. SEE EXTERIOR FINISH SCHEDULE FOR EXTERIOR

DOOR COLORS AND INTERIOR FINISH SCHEDULE

FOR INTERIOR DOOR COLORS.

3. REFER TO SHEET AE603 FOR CURTAIN WALL DOOR

FRAME TYPES.

1. 6'-0" DOORS ARE ACTUALLY PAIR OF 3'-0" DOORS

2. 5'-0" DOORS ARE ACTUALLY A 3'-0" DOOR & 2'-0" DOOR

3. STC RATED DOORS

4. ELECTRIC STRIKE & CARD READER

CAULK PERIMETER

OF DOOR FRAME

EACH SIDE

1 LAYER 5/8" GWB

EACH SIDE ON

3-5/8" METAL STUDS

HOLLOW METAL

FRAME

DOOR AS

SCHEDULED5 7/8"

5/8" 3 5/8" 5/8"

FOAM FILLED

ACOUSTIC

INSULATION

SOUND BATT. INSULATION

AS SCHEDULED

2 LAYER 5/8" GWB

ONE SIDE

CAULK PERIMETER

OF DOOR FRAME

EACH SIDE

SOUND BATT. INSULATION

AS SCHEDULED

HOLLOW METAL

FRAME

DOOR AS

SCHEDULED

3 5/8"

6 1/2"

FOAM FILLED

ACOUSTIC

INSULATION

1 LAYER 5/8" GWB ONE SIDE

ON 3-5/8" METAL STUDS

1 LAYER 5/8" GWB EACH

SIDE ON 3-5/8" METAL STUDS

DOOR AS SCHEDULED

HOLLOW METAL FRAME

CAULK PERIMETER OF

DOOR FRAME EACH SIDE

/8

FOAM FILLED ACOUSTIC

INSULATION

SOUND BATT. INSULATION

AS SCHEDULED

1 LAYER 5/8" GWB ONE SIDE

ON 3-5/8" METAL STUDS

DOOR AS SCHEDULED

CAULK PERIMETER OF

DOOR FRAME EACH SIDE

HOLLOW METAL FRAME

/2

FOAM FILLED ACOUSTIC INSULATION

2 LAYER 5/8" GWB ONE

SIDE

CAULK PERIMETER OF DOOR

FRAME EACH SIDE

1 LAYER 5/8" GWB EACH SIDE

ON 3-5/8" METAL STUDS

HOLLOW METAL FRAME

DOOR AS SCHEDULED

5 7/8"

FOAM FILLED

ACOUSTIC

INSULATION

SOUND BATT.

INSULATION AS

SCHEDULED

1 LAYER 5/8" GWB EACH

SIDE ON 3-5/8" METAL STUDS

DOOR AS

SCHEDULED

HOLLOW METAL

FRAME

CAULK PERIMETER OF

DOOR FRAME EACH SIDE

/8

FOAM FILLED

ACOUSTIC

INSULATION

SOUND BATT. INSULATION

AS SCHEDULED

7 5/8"

5 3/4"

1 LAYER 5/8" GWB EACH

SIDE ON 7/8" METAL HAT

CHANNELS

DOOR AS

SCHEDULED

HOLLOW METAL

FRAME

CAULK PERIMETER OF

DOOR FRAME EACH SIDE

EXISTING CMU WALL

PAINT

EXPOSED

SURFACE

1 LAYER 5/8" GWB EACH

SIDE ON 7/8" METAL HAT

CHANNELS

DOOR AS

SCHEDULED

HOLLOW METAL

FRAME

CAULK PERIMETER OF

DOOR FRAME EACH SIDE

EXISTING CMU WALL

/4

PAINT EXPOSED SURFACE

CL

EXISTING FLOOR

TO REMAIN

ALUM. THRESHHOLD SET

IN FULL BED OF MASTIC

DOOR AS SCHEDULED

5 3/4"

EXISTING EXTERIOR FINISH

DOOR AS SCHEDULED

CAULK PERIMETER OF

DOOR FRAME

EXISTING MASONRY WALL

2 1/2" 25 GA. METAL STUDS

@ 24" O.C. WITH 1 LAYER

5/8" GWB WITH 2" GLASS

FIBER BATT INSULATION

HOLLOW METAL DOOR

FRAME FILLED SOLID WITH

GROUT

EXISTING EXTERIOR FINISH

DOOR AS SCHEDULED

HOLLOW METAL FRAME

CAULK PERIMETER OF

DOOR FRAME

EXISTING MASONRY WALL

/4

2 1/2" 25 GA. METAL STUDS

@ 24" O.C. WITH 1 LAYER

5/8" GWB WITH 2" GLASS

FIBER BATT INSULATION

HOLLOW METAL DOOR

JAMB FILLED SOLID WITH

GROUT

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE601

K M

B D

O O

R S

C H

E D

U L E

T

Y P

E S

A

N D

D E

T A

IL

S

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

DOOR SCHEDULE

MARK ROOM NAME

ROOM

NUMBER

DOOR

HARDWARE

SET

FRAME

REMARKSWIDTH HEIGHT TYPE

DOOR

MATERIAL CLASSIFICATION PERFORMANCE FINISH COATING GLAZING STC RATING TYPE MATERIAL FINISH COATING HEAD JAMB THRESHOLD

102 VESTIBULE 102A 4' - 0" 7' - 0" F SC - - BIRCH ST - - - HW-2 HM4 HM FIELD PT 3/ AE601 4/ AE601

104 GENERAL STORAGE 104 5' - 0" 7' - 0" F1 HM XHD - FIELD PT - - - HW-1 HM3 HM FIELD PT 11/ AE60 12/ AE601 2, 4

104A GENERAL STORAGE 104 3' - 0" 7' - 0" F SC XHD - BIRCH ST - 45 - HW-4 HM1 HM FIELD PT 3/ AE601 4/ AE601 3

105 STORAGE 105 3' - 0" 7' - 0" F SC - - BIRCH ST - - - HW-5 HM2 HM FIELD PT 9/ AE601 10/ AE601

106 OPEN OFFICE 110 3' - 0" 7' - 0" F SC - - BIRCH ST - 45 - HW-3 HM5 HM FIELD PT 7/ AE601 8/ AE601 3

110 OPEN OFFICE 110 3' - 0" 7' - 0" F SC - - BIRCH ST - 45 - HW-3 HM1 HM FIELD PT 3/ AE601 4/ AE601 3

205 CONFERENCE ROOM 205 3' - 0" 7' - 0" F SC - - BIRCH ST - 50 - HW-3 HM1 HM FIELD PT 5/ AE601 6/ AE601 3

206 OPEN OFFICE 206 3' - 0" 7' - 0" F SC - - BIRCH ST - 50 HW-3 HM1 HM FIELD PT 5/ AE601 6/ AE601 3

206A OPEN OFFICE 206 3' - 0" 7' - 0" F SC - - BIRCH ST - - HW-2 HM1 HM FIELD PT 3/ AE601 4/ AE601

209 OFFICE 209 6' - 0" 7' - 0" S AL - - PRE-FINISHED ORG - - - AL1 AL PRE-FINISHED ORG 1

1/4" = 1'-0"AE601

1 DOOR FRAME TYPES LEGEND

1/4" = 1'-0"AE601

2 DOOR TYPE LEGEND

3" = 1'-0"AE601

3 HOLLOW METAL DOOR HEAD

3" = 1'-0"AE601

5 HOLLOW METAL DOOR HEAD

3" = 1'-0"AE601

4 HOLLOW METAL DOOR JAMB

3" = 1'-0"AE601

6 HOLLOW METAL DOOR JAMB

3" = 1'-0"AE601

7 HOLLOW METAL DOOR HEAD

3" = 1'-0"AE601

8 HOLLOW METAL DOOR JAMB

3" = 1'-0"AE601

9 HOLLOW METAL DOOR HEAD

3" = 1'-0"AE601

10 HOLLOW METAL DOOR HEAD

0" 2" 4" 0'-8"

3"=1'-0"

3" = 1'-0"AE601

13 MISC THRESHOLD DETAILS

3" = 1'-0"AE601

11 HOLLOW METAL DOOR HEAD

3" = 1'-0"AE601

12 HOLLOW METAL DOOR HEAD

M A

R K

D E

S C

R

IP

T

IO

N D

A T

PLAN

FINISH FLOOR AS

SCHEDULED

BASE AS

SCHEDULED

SECTION

3-5/8" 25 GA. METAL STUDS @ 24" O.C. WITH 1

LAYER 5/8" GWB ON BOTH SIDES WITH 3"

GLASS FIBER BATT INSULATION

WALL FINISHES

AS SCHEDULED CEILING FINISHES

AS SCHEDULED

UNDERSIDE DECK,

SLAB OR BEAM

ABOVE

3" GLASS FIBER

BATT INSULATION

ACOUSTICAL

SEALANT TOP/

BOTTOM AND

BOTH SIDES

NOT RATED

STC 45

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING: 45

PLAN

PARTITION TYPE DETAIL

1"=1'-0"

SECTION

NOT RATED

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING:

FINISH FLOOR AS SCHEDULED

BASE AS SCHEDULED

2 1/2" 25 GA. METAL STUDS @ 24" O.C. WITH 1 LAYER

5/8" GWB WITH 2" GLASS FIBER BATT INSULATION

WALL FINISHES

AS SCHEDULED

CEILING FINISHES

AS SCHEDULED

UNDERSIDE DECK,

SLAB OR BEAM

ABOVE

2 1/2" 25 GA. METAL STUDS

@ 24" O.C.

1 LAYER 5/8" GWB

3" GLASS FIBER

BATT INSULATION

1 LAYER 5/8" GWB

ON BOTH SIDES

EXISTING

MASONRY WALL

2A

PARTITION TYPE DETAIL

1"=1'-0"

WALL FINISHES AS SCHEDULED

WALL FINISHES AS SCHEDULED

PLAN

FINISH FLOOR AS

SCHEDULED

BASE AS

SCHEDULED

SECTION

3-5/8" 25 GA. METAL STUDS @ 24" O.C. WITH 1

LAYER 5/8" GWB ON BOTH SIDES

WALL FINISHES

AS SCHEDULED CEILING FINISHES

AS SCHEDULED

UNDERSIDE DECK,

SLAB OR BEAM

ABOVE

NOT RATED

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING: -

1 LAYER 5/8" GWB

ON BOTH SIDES

PARTITION TYPE DETAIL

1"=1'-0"

WALL FINISHES AS SCHEDULED

3 1/2"

PLAN

PARTITION TYPE DETAIL

1"=1'-0"

SECTION

NOT RATED

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING:

FINISH FLOOR AS SCHEDULED

BASE AS SCHEDULED

EXISTING MASONRY WALL

WALL FINISHES

AS SCHEDULED

CEILING FINISHES

AS SCHEDULED

UNDERSIDE DECK,

SLAB OR BEAM

ABOVE

7/8" METAL HAT CHANNELS

@ 24" O.C.

1 LAYER 5/8" GWB

EXISTING

MASONRY WALL

WALL FINISHES AS SCHEDULED

EXISTING MASONRY WALL

/2

PLAN

FINISH FLOOR AS

SCHEDULED

BASE AS

SCHEDULED

SECTION

(2) 3-5/8" 25 GA. METAL STUDS @ 24" O.C.

WITH 1 LAYER 5/8" GWB ON EACH SIDE

WALL FINISHES

AS SCHEDULED INFILL EXISTING

ROUGH OPENING

EXISTING

MASONRY WALL

NOT RATED

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING: -

1 LAYER 5/8" GWB

ON BOTH SIDES

PARTITION TYPE DETAIL

1"=1'-0"

WALL FINISHES AS SCHEDULED

FINISH FLOOR AS

SCHEDULED

BASE AS

SCHEDULED

7/8" METAL HAT

CHANNELS, BOTH SIDES

NEW PRECAST

LINTEL

7/8" METAL HAT CHANNELS @ 24" O.C. WITH 1 LAYER 5/8" GWB

NOT RATED

STC 50

FIRE RATING:

DESCRIPTION:

REMARKS:

UL DESIGN:

STC RATING: 50

2B

PARTITION TYPE DETAIL

1"=1'-0"

2 LAYERS OF GYPSUM TO INTERIOR

SIDE AND 1 LAYER ON OTHER SIDE

1. 20 GA. STUDS AND PLYWOOD BACKING REQUIRED WHERE WALL HUNG CABINETS AND APPURTENANCES OCCUR AND AT SELECT AREAS OF

IMPACT RESISTANCE. OTHERWISE GAUGE TO MEET MINIMUM PERFORMANCE OF WALL.

2. PROVIDE BRACING ABOVE CEILING FOR 25 GA. METAL STUDS SPACED 24" O.C. THAT EXCEED LIMITING HEIGHT FACTOR PER TABLES.

GENERAL NOTES:

EXISTING CMU WALL

7/8" HAT CHANNELS

5/8" GYPSUM BOARD

3 5/8" METAL STUD

ALIGN INFILL WALL WITH FURRED OUT CMU

EXISTING EXTERIOR CMU WALL

5/8" GYPSUM BOARD

2 1/2" METAL STUD

VERIFY LOCATION AND SIZE OF EXISTING

FIRE RISER

1" 2 1/2"

VIF

10"

V

IF

/2

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AE701

K M

B P

A R

T

IT

I O N

T Y

P E

S A

N D

P L A

N

D E

T A

IL

S

A E

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

1 1/2" = 1'-0"AE701

1 PLAN DETAIL

1 1/2" = 1'-0"AE701

2 PLAN DETAIL

0" 4" 8" 1'-4"

1 1/2"=1'-0"

0" 6" 12" 2'-0"

1"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

AE301

AE301

AE301

AE301

WORK SPACE

OFFICE

STORAGE

WORK SPACE

OFFICE/ STUDIO

OPEN OFFICE

GENERAL STORAGE

VESTIBULE

102A

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

STORAGE

ELEVATOR EQUIPMENT

AREA NOT IN CONTRACT

FINISH LEGEND

CPT-1

SC-1

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AF101

K M

B F

I R S

T F

L O

O R

F I N

IS

H

P L A

N

A F

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AF101

1 FIRST FLOOR FINISH PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

FEC

AE301

AE301

AE301

AE301

WORK SPACE

WORK SPACE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

OFFICE

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

1" / 12"

0"

3 1/2" 0"

3 1/2" 3 1/2"

0"

3 1/2"

AREA NOT IN CONTRACT

FINISH LEGEND

CPT-1

SC-1

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AF102

K M

B S

E C

O N

D F

L O

O R

F

IN

IS

H

P L A

N

A F

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AF102

1 SECOND FLOOR FINISH PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

BASIS OF DESIGN

ALL MANUFACTURERS, COLOR AND PRODUCT SELECTED ARE FOR IDENTIFICATION AND BASIS OF DESIGN PURPOSES ONLY; LISTING IS NOT

INTENDED TO LIMIT SELECTION OF SIMILAR COLORS FROM OTHER MANUFACTURERS.

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AF601

K M

B R

O O

M F

IN

IS

H S

C H

E D

U L E

A N

D

F

IN

I S H

K E

Y

A F

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

ROOM FINISH SCHEDULE

AT WALLS WHERE MORE THAN ONE FINISH IS NOTED INSTALL FINISH "TOP TO BOTTOM"

RM # ROOM NAME

FLOOR

FINISH

WALL

BASE

NORTH EAST SOUTH WEST CEILING

REMARKSFINISH FINISH FINISH FINISH MATERIAL FINISH

102A VESTIBULE CPT-1 RB-01 P-1 P-1 P-1 P-1 ACT-1 -

104 GENERAL STORAGE SC-1 RB-01 P-1 P-1 P-1 P-1 ACT-1 -

105 STORAGE SC-1 RB-01 P-1 P-1 P-1 P-1 - -

106 OFFICE CPT-1 RB-01 P-2 P-1 P-2 P-1 ACT-1 -

110 OPEN OFFICE CPT-1 RB-01 P-2 P-1 P-1 P-1 ACT-1 -

204 OFFICE CPT-1 RB-01 P-1 P-1 P-1 P-2 ACT-1 -

205 CONFERENCE ROOM CPT-1 RB-01 P-2 P-1 P-1 P-1 ACT-1 -

206 OPEN OFFICE CPT-1 RB-01 P-2 P-1 P-1 P-1 ACT-1 -

206A ELECTRICAL ROOM SC-1 RB-01 P-1 P-1 P-1 P-1 - -

209 OFFICE CPT-1 RB-01 P-2 P-1 P-1 P-1 ACT-1 -

FINISH KEY

FINISH CODE MATERIAL MANUFACTURER SERIES

FINISH FINISH FINISH

REMARKSSTYLE SIZE COLOR

FLOORING

CPT-1 CARPET TILE SHAW CONTRACT KASURI CARPET TILE 24" X 24" DESERT SAND

SC-1 EXISTING CONCRETE FLOOR TO REMAIN/ CLEAN AS REQUIRED - - - - - INFILL EXISTING RECESSED COOLER SLAB WITH CONCRETE FILL TO MATCH EXISTING FLOOR LEVEL

BASE

RB-1 RESILIENT BASE ROPPE RUBBER COVE 4" 194 BURNT UMBER

WALLS

P-1 WALL PAINT SHERWIN WILLIAMS PRO MAR 400 SATIN - TBD/ CONTRACTOR TO COORDINATE WITH GOV'T

P-2 WALL PAINT, ACCENT SHERWIN WILLIAMS PRO MAR 400 SATIN - TBD/ CONTRACTOR TO COORDINATE WITH GOV'T

P-3 PAINT, DOOR FRAME SHERWIN WILLIAMS PRO MAR 400 SEMI-GLOSS - TBD/ CONTRACTOR TO COORDINATE WITH GOV'T

CEILING

ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG FINE FISSURED MODEL 1754 24" X 24" WHITE

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

WORK SPACE

OFFICE

STORAGE

WORK SPACE

OFFICE/ STUDIO

OPEN OFFICE

GENERAL STORAGE

VESTIBULE

102A

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

A

AA1

A

B

102A

STORAGE

ELEVATOR EQUIPMENT

A1

A

B

104A

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AG101

K M

B F

IR

S

T F

L O

O R

S

IG

N A

G E

P L A

N

A G

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

3/16" = 1'-0"AG101

1 FIRST FLOOR SIGNAGE PLAN

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

FEC

WORK SPACE

WORK SPACE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

OFFICE

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

206A

209A

A

A1

A1

A1

A

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AG102

K M

B S

E C

O N

D F

L O

O R

S

IG

N A

G E

P L A

N

A G

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

3/16" = 1'-0"AG102

1 SECOND FLOOR SIGNAGE PLAN

M A

R K

D E

S C

R

IP

T

IO

N D

A T

PERMANENT HEADER

PANEL

1" HELVETICA REGULAR TEXT,

WHITE LETTERS AND NUMBERS

ON BACKGROUND. ROOM

LETTERS AND NUMBERS SHALL

BE RAISED 1/32" MIN.

GRADE TWO BRAILLE TO BE

BACKGROUND COLOR

PERMANENT ROOM

NAME

ROOM NAME

A

8"

1" HELVETICA REGULAR TEXT,

WHITE LETTERS AND NUMBERS

ON BACKGROUND. ROOM

LETTERS AND NUMBERS SHALL

BE RAISED 1/32" MIN.

GRADE TWO BRAILLE TO BE

BACKGROUND COLOR

B

AUTHORIZED

PERSONNEL

ONLY

8"

2 3

NOTE: MOUNT ON LATCH

SIDE OF DOOR OR ADJACENT

WALL. COORDINATE WITH

SIGNAGE LOCATION PLAN

MOUNT ON RIGHT SIDE OF

DOUBLE DOORS,

COORDINATE WITH SIGNAGE

LOCATION PLAN

6" 6"

NOTE: MOUNT ON CENTER

OF DOOR. COORDINATE

WITH SIGNAGE LOCATION

PLAN

EQ EQ

NOTE: MOUNT ON CENTER

OF DOOR. COORDINATE

WITH SIGNAGE LOCATION

PLAN

EQ EQ

1A

PERMANENT HEADER

PANEL

1" HELVETICA REGULAR TEXT,

WHITE LETTERS AND NUMBERS

ON BACKGROUND. ROOM

LETTERS AND NUMBERS SHALL

BE RAISED 1/32" MIN.

GRADE TWO BRAILLE TO BE

BACKGROUND COLOR

CHANGEABLE PLASTIC

NAME INSERT

ROOM NAME

A1

8"

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

AG601

K M

B S

IG

N

A G

E S

C H

E D

U L E

A N

D

E L E

V A

T

IO

N S

A G

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

SIGNAGE SCHEDULE

ROOM NO. ROOM NAME SIGNAGE WORDING DOOR # SIGN TYPE MOUNTING TYPE COMMENTS

102 OFFICE/ STUDIO OFFICE/STUDIO 102 A 2

104 GENERAL STORAGE AUTHORIZED PERSONNEL ONLY 104 B 3

104 GENERAL STORAGE GENERAL STORAGE 106 A 1

104 GENERAL STORAGE AUTHORIZED PERSONNEL ONLY 106 B 1A

105 STORAGE STORAGE 105 A 2

106 OFFICE OFFICE 106 A1 2

110 OPEN OFFICE OPEN OFFICE 110 A1 2

204 OFFICE OFFICE 204 A1 2

205 CONFERENCE ROOM CONFERENCE ROOM 205 A 2

206 OPEN OFFICE OPEN OFFICE 206 A1 2

206A ELECTRICAL ROOM ELECTRICAL ROOM 206A A 2

209 OFFICE OFFICE 209A A1 2

AG601 3" = 1'-0"

1 SIGNAGE TYPES

AG601 3/8" = 1'-0"

2 SIGNAGE MOUNTING TYPES

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

WORK SPACE

OFFICE

STORAGE

WORK SPACE

OFFICE/ STUDIO

OPEN OFFICE

GENERAL STORAGE

VESTIBULE

102A

FOYER

STAIR 1

CONFERENCE

STORAGE

STORAGE

UPS

MECHANICAL

COMM ROOM

WOMEN

MEN

JANITOR

STAIR 2

SHOWERS

TYP.

CH02

D02

D01

0"

3 1/2"

3 1/2"

STORAGE

ELEVATOR EQUIPMENT

D02

D01

TYP.

CH02

TYP.

TB02 D01

TYP.

TB03

SC03

TB04

TYP.

SC03

TYP.

SC02

SC04

TYP.

SC01

SC05

TB05

SC04

TB04

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

IF101

K M

B F

IR

S

T F

L O

O R

F U

R N

IT

U

R E

P L A

N

A N

D S

C H

E D

U L E

IF

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

0" 2'-8" 5'-4" 10'-8"

3/16"=1'-0"

PLAN

NORTH

N

3/16" = 1'-0"IF101

1 FIRST FLOOR FURNITURE PLAN

FURNITURE LEGEND

CODE ITEM REMARKS

CH01 CONFERENCE CHAIR GF/ CI

CH02 TASK CHAIR GF/ CI

CH03 GUEST CHAIR GF/ CI

D01 L-SHAPED DESK, LEFT HAND GF/ CI

D02 L-SHAPED DESK, RIGHT HAND GF/ CI

F01 STORAGE CREDENZA GF/ CI

SC01 STEEL CABINET GF/ CI

SC02 STEEL CABINET GF/ CI

SC03 STEEL CABINET GF/ CI

SC04 STEEL CABINET GF/ CI

SC05 STEEL CABINET GF/ CI

T02 CONFERENCE TABLE GF/ CI

TB01 WORK STATION GF/ CI

TB02 WORK STATION GF/ CI

TB03 WORK STATION GF/ CI

TB04 WORK STATION GF/ CI

TB05 WORK STATION GF/ CI

M A

R K

D E

S C

R

IP

T

IO

N D

A T

FEC

FEC

FEC

WORK SPACE

WORK SPACE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

ELECTRICAL ROOM

206A

OFFICE

OFFICE

MEN

STAIR 1

WORK SPACE

BREAK ROOM

HALL

WORK SPACE

WORK SPACE

STAIR 2

1" / 12"

3 1/2" 0"

3 1/2"

3 1/2"

0"

3 1/2"

TYP.

CH02

TYP.

CH01

T02

TYP.

CH02

TYP.

TB01

CH02

CH03

D01

F01

2 3/4"

SC01

SC04

SHEET

REFERENCE

NUMBER.

E F G H

D R

A W

N B

Y

D E

S I G

N B

Y

R E

V I E

W E

D B

Y

P R

O J E

C T

N U

M B

E R

D A

T E

D E

P A

R T

M E

N T

O F

T H

E A

R M

Y D

IR

E

C T

O R

A T

E O

F P

U B

L

IC

W O

R K

S F

O R

T B

R A

G G

N

O R

T H

C A

R O

L

IN

A

C H

E C

K E

D B

Y

D R

A W

IN

G

N U

M B

E R

D P

W -7

ISSUED FOR

CONSTRUCTION

FOR OFFICIAL USE ONLY

DCBA

S C

A L E

J

O N

E S

F R

A N

K L

IN

R

D S

U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9 -7

F

A X

L

IC

E N

S E

F

-0

BRAGG

S C

-0 -1

A S

S H

O W

N

J u n e

K M

B

S L J

R D

IF102

K M

B S

E C

O N

D F

L O

O R

F U

R N

IT

U

R E

P L A

N

IF

M O

D

IF

Y F

IR

S

T A

N D

S E

C O

N D

F L O

O R

B U

IL

D

IN

G

-1

J S

O C

0" 2'-8" 5'-4"…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .