AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Solicitation W912PM-16-B-0028 is hereby amended for the follow ing reason:
a) To provide changes to the plans and specifications in response to bidder inquiries. See Technical Summary of Changes, attached.
b) The date and time for receipt of bids is not changed.
c) All other terms, provisions, and conditions of the solicitation remain unchanged.
//////////////////////////////////////////////////// LAST ITEM \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 14-Sep-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912PM-16-B-0028
X 9B. DATED (SEE ITEM 11)
23-Aug-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
14-Sep-2016
CODE
U S ARMY CORPS OF ENGINEERS
ATTN: JERE F. WEST, 69 DARLINGTON AVE
WILMINGTON NC 28403
W912PM 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912PM-16-B-0028
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
(End of Summary of Changes)
W912PM-16-B-0028
Amendment 0004
TECHNICAL SUMMARY OF CHANGES
SPECIFICATIONS:
The revised Sections listed below (revised by Amendment No.
0004) is hereby added to and made a part of the solicitation.
Revised Sections 07 21 19 08 33 23
DRAWINGS:
Delete existing Sheet Numbers C-502 and CU101 in their entirety and replace with revised enclosed Sheets.
Encls As stated
SF-00005-16 - Renovate Storage Bldg O-1908, SOTF W912PM-16-B-0028 Fort. Bragg, NC
SECTION TABLE OF CONTENTS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
SECTION 07 21 19
RETROFIT BLANKET INSULATION SYSTEM
11/11
PART 1 GENERAL
1.1 REFERENCES
1.2 SYSTEM DESCRIPTION AND REQUIREMENTS
1.3 SUBMITTALS
1.4 SUSTAINABLE DESIGN CERTIFICATION
1.5 DELIVERY, STORAGE, AND HANDLING
1.5.1 Delivery
1.5.2 Storage
1.6 SAFETY PRECAUTIONS
1.6.1 Respirators
1.6.2 Other Safety Concerns
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
2.1.1 Recycled Content for Insulation Materials
2.1.2 Reduce Volatile Organic Compounds (VOC) for Insulation Materials
2.2 BLANKET INSULATION
2.2.1 Thermal Resistance Value (R-VALUE)
2.2.2 Recycled Materials
2.2.3 Prohibited Materials
2.2.4 Reduced Volatile Organic Compounds (VOC) for Insulation
Materials
2.3 BLOCKING
2.4 FABRIC LINER
2.5 PRESSURE SENSITIVE TAPE
2.6 STEEL STRAPS
2.7 ACCESSORIES
2.7.1 Adhesive
2.7.2 Mechanical Fasteners
2.7.3 Insulation Hangers
PART 3 EXECUTION
3.1 EXISTING CONDITIONS
3.2 PREPARATION
3.2.1 Blocking at Attic Vents and Access Doors
3.2.2 Blocking Around Heat Producing Devices
3.2.3 Existing Insulation
3.3 INSTALLATION
3.3.1 Insulation
3.3.1.1 Electrical wiring
3.3.1.2 Continuity of Insulation
3.3.1.3 Installation at Bridging and Cross Bracing
3.3.1.4 Cold Climate Requirement
SECTION 07 21 19 Page 1 (Revised by Amendment 0004)
3.3.1.5 Insulation without Affixed Vapor Retarder
3.3.1.6 Sizing of Blankets
-- End of Section Table of Contents --
SECTION 07 21 19 Page 2
SECTION 07 21 19
RETROFIT BLANKET INSULATION SYSTEM
11/11
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM C665 (2012) Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing
ASTM C930 (2012) Potential Health and Safety Concerns Associated with Thermal Insulation Materials and Accessories
ASTM C991 (2016) Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings
ASTM D3833/D3833M (1996; R 2011) Water Vapor Transmission of Pressure-Sensitive Tapes
ASTM E136 (2016) Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C
ASTM E84 (2015b) Standard Test Method for Surface Burning Characteristics of Building Materials
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2014; AMD 1 2013; Errata 1 2013; AMD 2 2013; Errata 2 2013; AMD 3 2014; Errata 3-4 2014; AMD 4-6 2014) National Electrical Code
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
29 CFR 1910.134 Respiratory Protection
UL ENVIRONMENT (ULE)
ULE Greenguard UL Greenguard Certification Program
1.2 SYSTEM DESCRIPTION AND REQUIREMENTS
Roof and wall insulation sytem of blanket insulation applied between girts and purlins of existing metal building structure and held in place utilizing plastic liner fabric, attachment fasteners, and steel straping.
SECTION 07 21 19 Page 3
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Blanket Insulation; G
Pressure Sensitive Tape
Accessories
Fabric Liner; G
SD-08 Manufacturer's Instructions
Insulation
Manufacturers Written Directions
SD-11 Closeout Submittals
Recycled Content for Insulation Materials; S
Reduce Volatile Organic Compounds (VOC) for Insulation Materials; S
1.4 SUSTAINABLE DESIGN CERTIFICATION
Product must be third party certified in accordance with ULE Greenguard.
1.5 DELIVERY, STORAGE, AND HANDLING
1.5.1 Delivery
Deliver materials to site in original sealed wrapping bearing manufacturer's name and brand designation, specification number, type, grade, R-value, and class. Store and handle to protect from damage. Do not allow insulation materials to become wet, soiled, crushed, or covered with ice or snow. Comply with manufacturer's recommendations for handling, storing, and protecting of materials before and during installation.
1.5.2 Storage
Inspect materials delivered to the site for damage; unload and store out of weather in manufacturer's original packaging. Store only in dry locations, not subject to open flames or sparks, and easily accessible for inspection and handling.
SECTION 07 21 19 Page 4
1.6 SAFETY PRECAUTIONS
1.6.1 Respirators
Provide installers with dust/mist respirators, training in their use, and protective clothing, all approved by National Institute for Occupational Safety and Health (NIOSH)/Mine Safety and Health Administration (MSHA) in accordance with 29 CFR 1910.134.
1.6.2 Other Safety Concerns
Consider other safety concerns and measures as outlined in ASTM C930.
PART 2 PRODUCTS
2.1 PRODUCT SUSTAINABILITY CRITERIA
For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:
2.1.1 Recycled Content for Insulation Materials
Provide insulation materials meeting the recycled content requirements as stated within this section and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph RECYCLED CONTENT.
2.1.2 Reduce Volatile Organic Compounds (VOC) for Insulation Materials
Provide insulation materials meeting the reduced VOC requirements as stated within this section and provide documentation in accordance with Section 01 33 29 SUSTAINABILITY REPORTING paragraph REDUCE VOLATILE ORGANIC
COMPOUNDS.
2.2 BLANKET INSULATION
ASTM C991, Type I, blankets without membrane coverings; Class A, when tested in accordance with ASTM E84.
2.2.1 Thermal Resistance Value (R-VALUE)
The R-Value must be as indicated on drawings.
2.2.2 Recycled Materials
Provide Thermal Insulation containing recycled materials to the extent practicable, provided the material meets all other requirements of this section. The minimum required recycled materials content by weight are:
Fiberglass: 20 to 25 percent glass cullet
2.2.3 Prohibited Materials
Do not provide asbestos-containing materials.
2.2.4 Reduced Volatile Organic Compounds (VOC) for Insulation Materials
ULE Greenguard.
SECTION 07 21 19 Page 5
2.3 BLOCKING
Wood, metal, unfaced mineral fiber blankets in accordance with ASTM C665, Type I, or other approved materials. Use only non-combustible materials meeting the requirements of ASTM E136 for blocking around chimneys and heat producing devices.
2.4 FABRIC LINER
Woven reinforced high-density polyethylene fabric coated on both sides with a continuous white polythylene film. Fabric shall comply with ASTM E84, Class A compliant with low flame spread index of 25 or less.
2.5 PRESSURE SENSITIVE TAPE
As recommended by the vapor retarder manufacturer and having a water vapor permeance rating of one perm or less when tested in accordance with
ASTM D3833/D3833M.
2.6 STEEL STRAPS
Minimum one inch wide by 0.020 inch thick steel strap of 100 KSI minimum yield high tensile strength, galvanized, primed, and finish painted white color on exposed face. Provide in continous length coils.
2.7 ACCESSORIES
2.7.1 Adhesive
As recommended by the insulation manufacturer.
Adhesives must follow the manufacturer's requirements for low pollutant emitting materials in achieving ULE Greenguard certification for their insulation products.
2.7.2 Mechanical Fasteners
Corrosion resistant fasteners as recommended by the insulation manufacturer.
2.7.3 Insulation Hangers
Angles, channels, preformed and punched wall hangers as provided and required by system manufacturer.
PART 3 EXECUTION
3.1 EXISTING CONDITIONS
Before installing insulation, ensure that areas that will be in contact with the insulation are dry and free of projections which could cause voids, compressed insulation, or punctured vapor retarders. If moisture or other conditions are found that do not allow the workmanlike installation of the insulation, do not proceed but notify Contracting Officer of such conditions.
SECTION 07 21 19 Page 6
3.2 PREPARATION
3.2.1 Blocking at Attic Vents and Access Doors
Prior to installation of insulation, install permanent blocking to prevent insulation from slipping over, clogging, or restricting air flow through soffit vents at eaves. Install permanent blocking to maintain accessibility to equipment or controls that require maintenance or adjustment.
3.2.2 Blocking Around Heat Producing Devices
Install non-combustible blocking around heat producing devices to provide the following clearances:
a. Recessed lighting fixtures, including wiring compartments, ballasts, and other heat producing devices, unless these are certified by the manufacturer for installation surrounded by insulation: 3 inches from outside face of fixtures and devices or as required by NFPA 70 and, if insulation is to be placed above fixture or device, 24 inches above fixture.
Blocking around flues and chimneys is not required when insulation blanket, including any attached vapor retarder, passed ASTM E136, in addition to meeting all other requirements stipulated in Part 2. Blocking is also not required if the chimneys are certified by the manufacturer for use in contact with insulating materials.
****Amendment 0004****
3.2.3 Existing Insulation
Existing insulation that remains in place shall be scored with 12 inch slits spaced 24 inches on center each way to allow the insulation to breathe and not create a vapor barrier between the old and new insulation.
Provide increased scoring as required by the new insulation Installer as needed.
****Amendment 0004****
3.3 INSTALLATION
3.3.1 Insulation
Install and handle insulation in accordance with manufacturer's instructions. Keep material dry and free of extraneous materials. Any materials that show visual evidence of biological growth due to presence of moisture must not be installed on the building project. Ensure personal protective clothing and respiratory equipment is used as required. Observe safe work practices.
Install the wall liner fabric neatly and squarely in the wall and ceiling bays in accordance with manufacturers written directions and secure with metal straps and mechanical fasteners. Seal liner fabric around any penetrations and wall openings.
3.3.1.1 Electrical wiring
Do not install insulation in a manner that would sandwich electrical wiring
SECTION 07 21 19 Page 7 between two layers of insulation.
3.3.1.2 Continuity of Insulation
Install blanket insulation to butt tightly against adjoining blankets and to purlins, girts, sill plates, headers and any obstructions. Provide continuity and integrity of insulation at corners, wall to ceiling joints, roof, and floor. Avoid creating thermal bridges.
3.3.1.3 Installation at Bridging and Cross Bracing
Insulate at bridging and cross bracing by splitting blanket vertically at center and packing one half into each opening. Butt insulation at bridging and cross bracing; fill in bridged area with loose or scrap insulation.
3.3.1.4 Cold Climate Requirement
Place insulation to the outside of pipes.
3.3.1.5 Insulation without Affixed Vapor Retarder
Provide snug friction fit to hold insulation in place. Stuff pieces of insulation into cracks between girts, purlins, steel framing,, door and window heads, jambs, and sills, and headers.
3.3.1.6 Sizing of Blankets
Provide only full width blankets when insulating between purlins and girts. Size width of blankets for a snug fit where framing members are irregularly spaced.
-- End of Section --
SECTION 07 21 19 Page 8
SECTION TABLE OF CONTENTS
DIVISION 08 - OPENINGS
SECTION 08 33 23
OVERHEAD COILING DOORS
08/15
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 QUALITY CONTROL
1.3.1 Powder Coatings Certificate
1.4 DELIVERY, STORAGE, AND HANDLING
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Design Requirements
2.1.1.1 Overhead Coiling Door Detail Shop Drawings
2.1.2 Performance Requirements
2.1.2.1 Wind Loading
2.1.2.2 Operational Cycle Life
2.2 COMPONENTS
2.2.1 Overhead Coiling Doors
2.2.1.1 Curtain Materials and Construction
2.2.1.2 Insulated Curtains
2.2.1.3 Curtain Bottom Bar
2.2.1.4 Locks
2.2.1.5 Weather Stripping
2.2.1.6 Locking Devices
2.2.1.7 Safety Interlock
2.2.1.8 Overhead Drum
2.2.1.9 Slats
2.2.2 Hardware
2.2.2.1 Guides
2.2.2.2 Equipment Supports
2.2.2.3 Hood
2.2.3 Counterbalancing Mechanism
2.2.3.1 Brackets
2.2.3.2 Counterbalance Barrels
2.2.4 Electric Door Operators
2.2.4.1 Door-Operator Types
2.2.4.2 Electric Motors
2.2.4.3 Motor Bearings
2.2.4.4 Motor Starters, Controls, and Enclosures
2.2.4.5 Control Enclosures
2.2.4.6 Transformer
2.2.4.7 Safety-Edge Device
2.2.4.8 Remote-Control Stations
2.2.4.9 Speed-Reduction Units
2.2.4.10 Chain Drives
2.2.4.11 Brakes
SECTION 08 33 23 Page 1
2.2.4.12 Clutches
2.2.4.13
2.2.5 Surface Finishing
PART 3 EXECUTION
3.1 INSTALLATION
3.2 ADJUSTING AND CLEANING
3.2.1 Acceptance Provisions
3.2.1.1 Maintenance and Adjustment
3.2.1.2 Cleaning
3.3 CLOSEOUT ACTIVITIES
3.3.1 Warranty
3.3.2 Operation And Maintenance
-- End of Section Table of Contents --
SECTION 08 33 23 Page 2
SECTION 08 33 23
OVERHEAD COILING DOORS
08/15
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
ASCE 7 (2010; Errata 2011; Supp 1 2013) Minimum Design Loads for Buildings and Other Structures
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING
ENGINEERS (ASHRAE)
ASHRAE FUN IP (2013; Addenda and Corrigendum 2013) Fundamentals Handbook, I-P Edition
ASME INTERNATIONAL (ASME)
ASME B29.400 (2001; R 2013) Combination, "H" Type Mill Chains, and Sprockets
ASTM INTERNATIONAL (ASTM)
ASTM A153/A153M (2016) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware
ASTM A27/A27M (2013) Standard Specification for Steel Castings, Carbon, for General Application
ASTM A307 (2014) Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength
ASTM A36/A36M (2014) Standard Specification for Carbon Structural Steel
ASTM A48/A48M (2003; R 2012) Standard Specification for Gray Iron Castings
ASTM A53/A53M (2012) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless
ASTM A653/A653M (2015) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by
SECTION 08 33 23 Page 3 the Hot-Dip Process
ASTM A780/A780M (2009; R 2015) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings
ASTM A924/A924M (2014) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM D2000 (2012) Standard Classification System for Rubber Products in Automotive Applications
ASTM D3451 (2006; R 2012) Testing Coating Powders and Powder Coatings
ASTM E330/E330M (2014) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
ASTM E84 (2015b) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM F568M (2007) Standard Specification for Carbon and Alloy Steel Externally Threaded Metric Fasteners
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
NEMA ICS 2 (2000; R 2005; Errata 2008) Standard for Controllers, Contactors, and Overload Relays Rated 600 V
NEMA ICS 6 (1993; R 2011) Enclosures
NEMA MG 1 (2014) Motors and Generators
NEMA ST 1 (1988; R 1994; R 1997) Specialty Transformers (Except General Purpose Type)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2014; AMD 1 2013; Errata 1 2013; AMD 2 2013; Errata 2 2013; AMD 3 2014; Errata 3-4 2014; AMD 4-6 2014) National Electrical Code
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SECTION 08 33 23 Page 4
SD-02 Shop Drawings
Overhead Coiling Doors; G
Counterbalancing Mechanism; G
Electric Door Operators; G
Bottom Bars; G
Guides; G
Mounting Brackets; G
Overhead Drum; G
Hood; G
Installation Drawings; G
SD-03 Product Data
Overhead Coiling Doors; G
Hardware; G
Counterbalancing Mechanism; G
Electric Door Operators; G
SD-05 Design Data
Overhead Coiling Doors; G
Hardware; G
Counterbalancing Mechanism; G
Electric Door Operators; G
Powder Coatings Certificate; G
SD-10 Operation and Maintenance Data
Operation and Maintenance Manuals; G
Materials; G
Devices; G
Procedures; G
Manufacture's Brochures; G
Parts Lists; G
SD-11 Closeout Submittals
Warranty; G
SECTION 08 33 23 Page 5
1.3 QUALITY CONTROL
1.3.1 Powder Coatings Certificate
Submit a certificate from the manufacturer stating that the powder coat conforms to ASTM D3451.
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver doors to the jobsite wrapped in a protective covering with the brands and names clearly marked thereon. Store doors in an adequately ventilated dry location that is free from dirt and dust, water, or other contaminants. Store in a manner that permits easy access for inspection and handling.
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
Doors to be coiling type, with interlocking slats, complete with anchoring and door hardware, guides, hood, and operating mechanisms, and designed for use on openings as indicated. Use grease-sealed or self-lubricating bearings for rotating members.
2.1.1 Design Requirements
2.1.1.1 Overhead Coiling Door Detail Shop Drawings
Provide installation drawings for overhead coiling door assemblies which show: elevations of each door type, shape and thickness of materials, finishes, details of joints and connections, details of guides and fittings, rough opening dimensions, location and description of hardware, anchorage locations, and counterbalancing mechanism and door operator details. Show locations of replaceable fusible links on wiring diagrams for power, signal and controls. Include a schedule showing the location of each door with the drawings.
2.1.2 Performance Requirements
2.1.2.1 Wind Loading
Design and fabricate door assembly to withstand the wind loading pressure as required by local building codes with a maximum deflection of 1/120 of the opening width. Provide test data showing compliance with ASTM E330/E330M. Sound engineering principles may be used to interpolate or extrapolate test results to door sizes not specifically tested. Ensure complete assembly meets or exceeds the requirements of ASCE 7.
2.1.2.2 Operational Cycle Life
Design all portions of the door, hardware and operating mechanism that are subject to movement, wear, or stress fatigue to operate through a minimum number of 10 cycles per day. One complete cycle of door operation is defined as when the door is in the closed position, moves to the fully open position, and returns to the closed position.
SECTION 08 33 23 Page 6
2.2 COMPONENTS
2.2.1 Overhead Coiling Doors
2.2.1.1 Curtain Materials and Construction
Provide curtain slats fabricated from Grade A steel sheets conforming to ASTM A653/A653M, with the additional requirement of a minimum yield point of 33,000 psi. Provide sheets, galvanized in accordance with ASTM A653/A653M and ASTM A924/A924M.
Fabricate doors from interlocking cold-rolled slats, with section profiles as specified, designed to withstand the local requirements for wind loading. Ensure the provided slats are continuous without splices for the width of the door.
2.2.1.2 Insulated Curtains
Form Curtains from manufacturer's standard shapes of interlocking slats.
Supply slat system with a minimum R-value of 4 when calculated in accordance with ASHRAE FUN IP. Slats to consist of a polystyrene core not less than 11/16-inch thick, completely enclosed within metal facings.
Ensure the exterior face of slats are the same gauge as specified for curtains. Select an interior face not lighter than 0.0219-inches. The insulated slat assembly requires a flame spread rating of not more than 25 and a smoke development factor of not more than 50 when tested in accordance with ASTM E84.
2.2.1.3 Curtain Bottom Bar
Install curtain bottom bars as pairs of angles from the manufacturer's standard steel, not less than 2.0 by 2.0-inches by 0.188-inch. Ensure steel extrusions conform to ASTM A36/A36M. Galvanize angles and fasteners in accordance with ASTM A653/A653M and ASTM A924/A924M. Coat welds and abrasions with paint conforming to ASTM A780/A780M.
2.2.1.4 Locks
Provide end and/or wind locks of Grade B cast steel conforming to ASTM A27/A27M, galvanized in accordance with ASTM A653/A653M, ASTM A153/A153M and ASTM A924/A924M. Secure locks at every other curtain slat.
2.2.1.5 Weather Stripping
Ensure weather-stripping at the door-head and jamb is 1/8-inch thick sheet of natural or neoprene rubber with air baffles. Secure weather stripping to the insides of hoods with galvanized-steel fasteners through continuous galvanized-steel pressure bars at least 5/8-inch wide and 1/8-inch thick.
Ensure threshold weather-stripping is 1/8-inch thick sheet natural or neoprene rubber secured to the bottom bars.
Provide weather-stripping of natural or neoprene rubber conforming to
ASTM D2000.
2.2.1.6 Locking Devices
Ensure slide bolt engages through slots in tracks for locking by padlock, SECTION 08 33 23 Page 7 located on both left and right jamb sides, operable from coil side.
2.2.1.7 Safety Interlock
Equip power-operated doors with safety interlock switch to disengage power supply when door is locked.
2.2.1.8 Overhead Drum
Fabricate drums from nominal 0.028-inch thick, hot-dip galvanized steel sheet with G90 (Z275) zinc coating, complying with ASTM A653/A653M.
2.2.1.9 Slats
No. 5F, 22 gauge, Grade 40 steel, ASTM A653/A653M galvanized steel zinc coating.
2.2.2 Hardware
Ensure all hardware conforms to ASTM A153/A153M, ASTM A307, ASTM F568M, and
ASTM A27/A27M.
2.2.2.1 Guides
Fabricate curtain jamb guides from the manufacturer's standard angles or channels of same material and finish as curtain slats unless otherwise indicated. Provide guides with sufficient depth and strength to retain curtain, and to withstand loading. Ensure curtain operates smoothly. Slot bolt holes for track adjustment.
2.2.2.2 Equipment Supports
Fabricate door-operating equipment supports from the manufacturer's standard steel shapes and plates conforming to ASTM A36/A36M, galvanized in accordance with ASTM A653/A653M and ASTM A924/A924M. Size the shapes and plates in accordance with the industry standards for the size, weight, and type of door installation.
2.2.2.3 Hood
Provide a hood with a minimum 24-gauge galvanized sheet metal, flanged at top for attachment to header and flanged at bottom to provide longitudinal stiffness. The hood encloses the curtain coil and counterbalance mechanism.
2.2.3 Counterbalancing Mechanism
Counterbalance doors by means of manufacturer's standard mechanism with an adjustable-tension, steel helical torsion spring mounted, around a steel shaft and contained in a spring barrel connected to top of curtain with barrel rings. Use grease-sealed or self-lubricating bearings for rotating members.
2.2.3.1 Brackets
Provide the manufacturer's standard mounting brackets with one located at each end of the counterbalance barrel conforming to ASTM A48/A48M. Provide brackets of either cast iron or cold-rolled steel.
SECTION 08 33 23 Page 8
2.2.3.2 Counterbalance Barrels
Fabricate spring barrel of manufacturer's standard hot-formed, structural-quality, welded or seamless carbon-steel pipe, conforming to ASTM A53/A53M. Ensure the barrel is of sufficient diameter and wall thickness to support rolled-up curtain without distortion of slats. Limit barrel deflection to not more than 0.03 inch per foot of span under full load.
a. Barrel
Provide steel pipe capable of supporting curtain load with maximum deflection of 0.03 inches per foot of width.
b. Spring Balance
Provide an oil-tempered, heat-treated steel helical torsion spring assembly designed for proper balance of door. Ensure that effort to operate manually operated units does not exceed 25 lbs. Provide wheel for applying and adjusting spring torque.
2.2.4 Electric Door Operators
Provide electrical wiring and door operating controls conforming to the applicable requirements of NFPA 70.
Electric door-operator assemblies needs to be the sizes and capacities recommended and provided by the door manufacturer for specified doors.
Furnish complete assemblies with electric motors and factory-prewired motor controls, starter, gear reduction units, solenoid-operated brakes, clutch, remote-control stations, manual or automatic control devices, and accessories as required for proper operation of the doors.
Design the operators so that motors may be removed without disturbing the limit-switch adjustment and affecting the emergency auxiliary operators.
Provide a manual operator of crank-gear or chain-gear mechanisms with a release clutch to permit manual operation of doors in case of power failure. Arrange the emergency manual operator so that it may be put into and out of operation from floor level, and its use does not affect the adjustment of the limit switches. Provide an electrical or mechanical device that automatically disconnects the motor from the operating mechanism when the emergency manual operating mechanism is engaged.
2.2.4.1 Door-Operator Types
Field assess and determine types of operators required to fit with existing conditions for clearances and headroom.
2.2.4.2 Electric Motors
Provide motors which are the high-starting-torque, reversible, constant-duty electrical type with overload protection of sufficient torque and horsepower to move the door in either direction from any position.
Ensure they produce a door-travel speed of not less than 8 nor more than 12 inches per second without exceeding the horsepower rating.
Provide motors which conform to NEMA MG 1 designation, temperature rating, service factor, enclosure type, and efficiency to the requirements
SECTION 08 33 23 Page 9 specified.
2.2.4.3 Motor Bearings
Select bearings with bronze-sleeve or heavy-duty ball or roller antifriction type with full provisions for the type of thrust imposed by the specific duty load.
Pre-lubricate and factory seal bearings in motors less than 1/2 horsepower.
Equip motors coupled to worm-gear reduction units with either ball or roller bearings.
Equip bearings in motors 1/2 horsepower or larger with lubrication service fittings. Fit lubrication fittings with color-coded plastic or metal dust caps.
In any motor, bearings that are lubricated at the factory for extended duty periods do not need to be lubricated for a given number of operating hours. Display this information on an appropriate tag or label on the motor with instructions for lubrication cycle maintenance.
2.2.4.4 Motor Starters, Controls, and Enclosures
Provide each door motor with: a factory-wired, unfused, disconnect switch;
a reversing, across-the-line magnetic starter with thermal overload protection; 120-volt operating coils with a control transformer limit switch; and a safety interlock assembled in a NEMA ICS 6 type enclosure as specified herein. Ensure control equipment conforms to NEMA ICS 2.
Provide adjustable switches, electrically interlocked with the motor controls and set to stop the door automatically at the fully open and fully closed position.
2.2.4.5 Control Enclosures
Provide control enclosures that conform to NEMA ICS 6 for general purpose NEMA Type 1.
2.2.4.6 Transformer
Provide starters with 230/460 to 115 volt control transformers with one secondary fuse when required to reduce the voltage on control circuits to 120 volts or less. Provide a transformer conforming to NEMA ST 1.
2.2.4.7 Safety-Edge Device
Provide each door with a pneumatic safety device extending the full width of the door and located within a U-section neoprene or rubber astragal, mounted on the bottom rail of the bottom door section. Device needs to immediately stop and reverse the door upon contact with an obstruction in the door opening during downward travel and cause the door to return to full-open position. A safety device is not a substitute for a limit switch.
Connect safety device to the control circuit through a retracting safety cord and reel.
SECTION 08 33 23 Page 10
2.2.4.8 Remote-Control Stations
Provide interior remote control stations which are full-guarded, momentary-contact three-button, heavy-duty, surface-mounted NEMA ICS 6 type enclosures as specified. Mark buttons "OPEN," "CLOSE," and "STOP." Ensure the "CLOSE" button requires a constant pressure to maintain the closing motion of the door. When the door is in motion and the "STOP" button is pressed, ensure the door stops instantly and remains in the stopped position. From the stopped position, the door may then be operated in either direction.
2.2.4.9 Speed-Reduction Units
Provide speed-reduction units consisting of hardened-steel worm and bronze worm gear assemblies running in oil or grease and inside a sealed casing, coupled to the motor through a flexible coupling. Drive shafts need to rotate on ball- or roller-bearing assemblies that are integral with the unit.
Provide minimum ratings of speed reduction units in accordance with AGMA provisions for class of service.
Ground worm gears to provide accurate thread form; machine teeth for all other types of gearing. Surface harden all gears.
Provide antifriction type bearings equipped with oil seals.
2.2.4.10 Chain Drives
Provide roller chains that are a power-transmission series steel roller type conforming to ASME B29.400, with a minimum safety factor of 10 times the design load.
Heat-treat or otherwise harden roller-chain side bars, rollers, pins, and bushings.
Provide high-carbon steel chain sprockets with machine-cut hardened teeth, finished bore and keyseat, and hollow-head setscrews.
2.2.4.11 Brakes
Provide 360-degree shoe brakes or shoe and drum brakes. Ensure the brakes are solenoid-operated and electrically interlocked to the control circuit to set automatically when power is interrupted.
2.2.4.12 Clutches
Ensure clutches are either the 4-inch diameter, multiple face, externally adjustable friction type or adjustable centrifugal type.
****Amendment 0004****
2.2.4.13 Weather/Smoke Seal Sensing Edge
Provide automatic stop control by an automatic sensing switch within neoprene astragal extending the full width of door bottom bar.
Provide an electric sensing edge device. Ensure the door immediately stops downward travel when contact occurs before door fully closes. Provide a
SECTION 08 33 23 Page 11 self-monitoring wireless sensing edge connection to the motor operator;
eliminating the need for a physical traveling electric cord connection between bottom bar sensing edge device and motor operator. Supervised system alters normal door operation; preventing damage, injury or death due to an inoperable sensing edge system.
****Amendment 0004****
2.2.5 Surface Finishing
Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.
Noticeable variations in the same metal component are not acceptable.
Variations in appearance of adjoining components are acceptable if they are within the range of approved samples and are assembled or installed to minimize contrast.
Powder-coat all exposed to view interior and exterior surfaces with electrostatic zinc coating prior to painting. Powder coating shall be electrostatically applied and oven cured. Polyester powder coating shall be resistant to ultraviolet (UV) light. Provide custom color of "Canterbury Blue."
PART 3 EXECUTION
3.1 INSTALLATION
Install overhead coiling door assembly, anchors and inserts for guides, brackets, motors, switches, hardware, and other accessories in accordance with approved detail drawings and manufacturer's written instructions.
Upon completion of installation, ensure doors are free from all distortion.
Install overhead coiling doors, motors, hoods, and operators at the mounting locations as indicated for each door in the contract documents and as required by the manufacturer.
Install overhead coiling doors, switches, and controls along accessible routes in compliance with regulatory requirements for accessibility and as required by the manufacturer.
3.2 ADJUSTING AND CLEANING
3.2.1 Acceptance Provisions
After installation, adjust hardware and moving parts. Lubricate bearings and sliding parts as recommended by manufacturer to provide smooth operating functions for ease movement, free of warping, twisting, or distortion of the door assembly.
Adjust seals to provide weather-tight fit around entire perimeter.
Engage a factory-authorized service representative to perform startup service and checks according to manufacturer's written instructions.
Test the door opening and closing operation when activated by controls or alarm-connected fire-release system. Adjust controls and safeties. Replace damaged and malfunctioning controls and equipment. Reset door-closing mechanism after successful test.
SECTION 08 33 23 Page 12
Test and make final adjustment of new doors at no additional cost to the Government.
3.2.1.1 Maintenance and Adjustment
Not more than 90 calendar days after completion and acceptance of the project, examine, lubricate, test, and re-adjust doors as required for proper operation.
3.2.1.2 Cleaning
Clean doors in accordance with manufacturer's approved instructions.
3.3 CLOSEOUT ACTIVITIES
3.3.1 Warranty
Furnish a written guarantee that the helical spring and counterbalance mechanism are free from defects in material and workmanship for not less than two years after completion and acceptance of the project.
Warrant that upon notification by the Government, any defects in material, workmanship, and door operation are immediately correct within the same time period covered by the guarantee, at no cost to the Government.
3.3.2 Operation And Maintenance
Submit 6 copies of the Operation and Maintenance Manuals 30 calendar days prior to testing the Overhead Coiling Door Assemblies. Update and resubmit data for final approval no later than 30 calendar days prior to contract completion.
Submit Operation and Maintenance Manuals for Overhead Coiling Door Assemblies, including the following items:
Materials
Devices
Electric Door Operators
Hood
Counterbalancing Mechanism
Painting
Procedures
Manufacture's Brochures
Parts Lists
Provide operation and maintenance manuals which are consistent with manufacturer's standard brochures, schematics, printed instructions, operating procedures, and safety precautions. Provide test data that is legible and of good quality.
-- End of Section --
SECTION 08 33 23 Page 13
| Amendment 0004 - SF-00005-16 |
| TECHNICAL SUMMARY OF CHANGES |
| DIVISION 07 - THERMAL AND MOISTURE PROTECTION |
| 07 21 19 - RETROFIT BLANKET INSULATION SYSTEM |
| RETROFIT BLANKET INSULATION SYSTEM |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SYSTEM DESCRIPTION AND REQUIREMENTS |
| 1.3 SUBMITTALS |
| 1.4 SUSTAINABLE DESIGN CERTIFICATION |
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| 1.5.1 Delivery |
| 1.5.2 Storage |
| 1.6 SAFETY PRECAUTIONS |
| 1.6.1 Respirators |
| 1.6.2 Other Safety Concerns |
| PART 2 PRODUCTS |
| 2.1 PRODUCT SUSTAINABILITY CRITERIA |
| 2.1.1 Recycled Content for Insulation Materials |
| 2.1.2 Reduce Volatile Organic Compounds VOC for Insulation Materials |
| 2.2 BLANKET INSULATION |
| 2.2.1 Thermal Resistance Value R-VALUE |
| 2.2.2 Recycled Materials |
| 2.2.3 Prohibited Materials |
| 2.2.4 Reduced Volatile Organic Compounds VOC for Insulation Materials |
| 2.3 BLOCKING |
| 2.4 FABRIC LINER |
| 2.5 PRESSURE SENSITIVE TAPE |
| 2.6 STEEL STRAPS |
| 2.7 ACCESSORIES |
| 2.7.1 Adhesive |
| 2.7.2 Mechanical Fasteners |
| 2.7.3 Insulation Hangers |
| PART 3 EXECUTION |
| 3.1 EXISTING CONDITIONS |
| 3.2 PREPARATION |
| 3.2.1 Blocking at Attic Vents and Access Doors |
| 3.2.2 Blocking Around Heat Producing Devices |
| 3.2.3 Existing Insulation |
| 3.3 INSTALLATION |
| 3.3.1 Insulation |
| 3.3.1.1 Electrical wiring |
| 3.3.1.2 Continuity of Insulation |
| 3.3.1.3 Installation at Bridging and Cross Bracing |
| 3.3.1.4 Cold Climate Requirement |
| 3.3.1.5 Insulation without Affixed Vapor Retarder |
| 3.3.1.6 Sizing of Blankets |
| DIVISION 08 - OPENINGS |
| 08 33 23 - OVERHEAD COILING DOORS |
| OVERHEAD COILING DOORS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 QUALITY CONTROL |
| 1.3.1 Powder Coatings Certificate |
1.4 DELIVERY, STORAGE, AND HANDLING
| PART 2 PRODUCTS |
| 2.1 SYSTEM DESCRIPTION |
| 2.1.1 Design Requirements |
| 2.1.1.1 Overhead Coiling Door Detail Shop Drawings |
| 2.1.2 Performance Requirements |
| 2.1.2.1 Wind Loading |
| 2.1.2.2 Operational Cycle Life |
| 2.2 COMPONENTS |
| 2.2.1 Overhead Coiling Doors |
| 2.2.1.1 Curtain Materials and Construction |
| 2.2.1.2 Insulated Curtains |
| 2.2.1.3 Curtain Bottom Bar |
| 2.2.1.4 Locks |
| 2.2.1.5 Weather Stripping |
| 2.2.1.6 Locking Devices |
| 2.2.1.7 Safety Interlock |
| 2.2.1.8 Overhead Drum |
| 2.2.1.9 Slats |
| 2.2.2 Hardware |
| 2.2.2.1 Guides |
| 2.2.2.2 Equipment Supports |
| 2.2.2.3 Hood |
| 2.2.3 Counterbalancing Mechanism |
| 2.2.3.1 Brackets |
| 2.2.3.2 Counterbalance Barrels |
| 2.2.4 Electric Door Operators |
| 2.2.4.1 Door-Operator Types |
| 2.2.4.2 Electric Motors |
| 2.2.4.3 Motor Bearings |
| 2.2.4.4 Motor Starters, Controls, and Enclosures |
| 2.2.4.5 Control Enclosures |
| 2.2.4.6 Transformer |
| 2.2.4.7 Safety-Edge Device |
| 2.2.4.8 Remote-Control Stations |
| 2.2.4.9 Speed-Reduction Units |
| 2.2.4.10 Chain Drives |
| 2.2.4.11 Brakes |
| 2.2.4.12 Clutches |
| 2.2.4.13 Weather/Smoke Seal Sensing Edge |
2.2.5 Surface Finishing
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.2 ADJUSTING AND CLEANING |
| 3.2.1 Acceptance Provisions |
| 3.2.1.1 Maintenance and Adjustment |
| 3.2.1.2 Cleaning |
| 3.3 CLOSEOUT ACTIVITIES |
| 3.3.1 Warranty |
| 3.3.2 Operation And Maintenance |
File details come from the government source that posted it. Updated .