FY17 MILCON F-35 Squadron Operations/Aircraft Maintenance Unit 5, Luke AFB, AZ
Appendix W:
Bldg. 913 and 926 Asbestos & Lead Reports lavinekx Cloud lavinekx Typewritten Text Appendix W has been updated to include the Asbestos report for bldg.913.
DEPARTMENT OF THE AIR FORCE
56th CIVIL ENGINEER SQUADRON (AETC)
LUKE AIR FORCE BASE, ARIZONA
12 November 2012
MEMORANDUM FOR: 56 CES/CEPM
ATTENTION: SrA Foster
FROM: 56 CES/CEAN
SUBJECT: NUEX 11-1391; Renovate Restrooms, and NUEX 12-1317; Renovate Supply
Hallway, Building 291-Asbestos Survey and Sampling Results
1. On 30 October 2012 an asbestos inspection and corresponding sampling was performed to ensure the accuracy of original asbestos survey conducted in building 913 for the for subject project renovations.
2. The survey was conducted to determine whether the building material that would be disturbed during this project were tested for asbestos and/or to ensure that the material has not changed since the original survey dated 3 Apr 02. Additional samples were taken and analyzed from the impacted area (restrooms – tiles, grout, and caulking) and do not contain asbestos. ACM is present within the facility at for Pipe Fittings, roof tar, 12x12 Brown Floor Tile Adhesive, and Window/Door Glazing, Caulking Compounds. If these materials are to be disturbed, a management plan for containing any release and waste must be approved prior any renovations.
3. A copy of this letter and results must be on hand during the renovation. Failure to have this report available can trigger a NESHAP Notice of Violation with the Maricopa County Air Quality Division. A new inspection must be performed if the renovation is not performed within one year of the date of this letter.
4. If there is a change in the scope of work or you have any additional questions regarding this survey, please contact me at 6-8486.
//SIGNED//
JEFFERY D. SCHONE
Asbestos Program Manager
Attachments:
1. Re-certification Letter (9 Nov 12)
2. Original Asbestos Survey (22 Nov 99)
October 9, 2012
Ms. Yvonne Newell Asset Management Flight Luke A.F.B.
56 CES/CEAN
13970 Gillespie Street Luke A.F.B., Arizona 85309-1149
Re: NESHAP Asbestos Re-Certification:
Luke AFB Project No.: NUEX11-1391 Building 913 Restroom Project
Dear Ms. Newell:
Continental Envirotech, Inc. (CEI) is pleased to provide Maricopa Luke AFB, Asset Management Flight with this updated asbestos survey letter for the above referenced site. A thorough walk through was conducted of the restroom remodel area(s). A complete review of the above referenced area was conducted and there have been no changes in the structure or in the composition of building materials since the previous asbestos survey performed by Environomics on November 22, 1999. The following table summarizes the ACM that tested positive for asbestos content.
Table 1: ACM Summary
Material Information Abatement /Demo Classification (If material is subject to removal, repair, damage or demolition of any kind) HA # Material Assumed /
Tested Positive Approximate
Amount Friable
(Yes/No) OSHA Class NESHAP Category
*14 Pipe Fittings Tested Positive 40 Fittings Yes Class I RACM *17 Roof Tar Tested Positive N/A No Class II Cat. I 9 12x12 Brown Floor Tile
Adhesive Tested Positive 546 SF No Class II Cat. I
13 Window/Door Glazing, Caulking Compound
Tested Positive N/A No Class II Cat. I
For more information regarding the asbestos survey originally performed by Environomics on November 22, 1999, please consult Environomics Project No. 1629. I have enclosed the EPA/AHERA Inspector certification for the update inspection. If you have any questions or need further information or assistance, please contact me at 480/ 844-1710.
Sincerely, Continental Envirotech, Inc.
Steven Chamberlain Field Services Manager
October 9, 2012
Asset Management Flight Luke A.F.B.
56 CES/CEAN
13970 Gillespie Street Luke A.F.B., Arizona 85309-1149
Re: NESHAP Asbestos Re-Certification:
Luke AFB Building 913 Restroom Project
Luke AFB Project No.: NUEX11-1391 CEI Project No. 12-18182C
Dear Ms. Newell:
Continental Envirotech, Inc. (Continental) is pleased to provide you with results of limited asbestos bulk sampling performed at the above referenced site on October 2, 2012. Continental’s scope of work included sampling and analysis for asbestos content, materials currently proposed for renovation activities which have not been previously sampled. The following tables summarize the results of the inspection and bulk sampling performed.
Table 1: Bulk Sampling & Analysis Summary Homogeneous
Area # Laboratory
ID #
Sample
ID #
Material Sample Location
Results
1 1 1 6x6 Ceramic Tile / Brown Battery Shop Center Island @ Drain Negative 1 2 2 6x6 Ceramic Tile / Brown Battery Shop Center Island NEC 3’ AFS Negative 1 3 3 6x6 Ceramic Tile / Brown Battery Shop Center Island SWC 3’ AFS Negative 2 4 4 Ceramic Tile Grout Battery Shop Center Island @ Drain Negative 2 5 5 Ceramic Tile Grout Battery Shop Center Island NEC 3’ AFS Negative 2 6 6 Ceramic Tile Grout Battery Shop Center Island SWC 3’ AFS Negative 3 7 7 6x6 Ceramic Tile / Red
Brown Battery Shop Floor NEC @ FS Negative
3 8 8 6x6 Ceramic Tile / Red Brown
Battery Shop Floor SWC @ FS Negative
3 9 9 6x6 Ceramic Tile / Red Brown
Battery Shop Floor SEC @ FS Negative
4 10 10 Ceramic Tile Grout Battery Shop Floor NEC @ FS Negative 4 11 11 Ceramic Tile Grout Battery Shop Floor SWC @ FS Negative 4 12 12 Ceramic Tile Grout Battery Shop Floor SEC @ FS Negative 5 13 13 6x6 Ceramic Tile / Brown Break Room Men’s R/R SWC @ FS Negative 5 14 14 6x6 Ceramic Tile / Brown Break Room Men’s R/R Under Sink @ FS Negative 5 15 15 6x6 Ceramic Tile / Brown Break Room Women’s R/R SEC @ FS Negative
Luke A.F.B.
56 CES/CEAN
Table 1: Bulk Sampling & Analysis Summary Homogeneous
Area # Laboratory
ID #
Sample
ID #
Material Sample Location
Results
6 16 16 Ceramic Tile Grout Break Room Men’s R/R SWC @ FS Negative 6 17 17 Ceramic Tile Grout Break Room Men’s R/R Under Sink @ FS Negative 6 18 18 Ceramic Tile Grout Break Room Women’s R/R SEC @ FS Negative 7 19 19 4x10 Wall Tile / Gold South Men’s R/R S. Wall NEC 5’ AFS Negative 7 20 20 4x10 Wall Tile / Gold South Men’s R/R E. Wall SEC 1’ AFS Negative 7 21 21 4x10 Wall Tile / Gold South Men’s R/R N. Wall NEC 4’ AFS Negative 8 22 22 Ceramic Tile Grout South Men’s R/R S. Wall NEC 5’ AFS Negative 8 23 23 Ceramic Tile Grout South Men’s R/R E. Wall SEC 1’ AFS Negative 8 24 24 Ceramic Tile Grout South Men’s R/R N. Wall NEC 4’ AFS Negative 9 25 25 Fixture Caulking Break Room Men’s R/R Sink Negative 9 26 26 Fixture Caulking S. R/R Men’s Sink Negative 9 27 27 Fixture Caulking S. R/R Women’s Sink Negative
Table 2: ACM Summary
Material Information Abatement /Demo Classification (If material is subject to removal, repair, damage or demolition of any kind) HA # Material Assumed /
Tested Positive Approximate
Amount Friable
(Yes/No) OSHA Class NESHAP Category
*14 Pipe Fittings Tested Positive 40 Fittings Yes Class I RACM *17 Roof Tar Tested Positive N/A No Class II Cat. I 9 12x12 Brown Floor Tile
Adhesive Tested Positive 546 SF No Class II Cat. I
13 Window/Door Glazing, Caulking Compound
Tested Positive N/A No Class II Cat. I
* These materials were identified in a previous asbestos inspection performed by Environomics on November 22, 1999. For more information, please consult the Environomics report No. 1629.
This inspection/sampling was not a complete study of the entire area, building or site. Only the materials specified in this report were tested. Materials not sampled should always be assumed asbestos until proven not asbestos by a certified AHERA building inspector.
We have performed our services for this project in accordance with our agreement and understanding with our client. This document and information contained herein have been prepared solely for the use of our clients and their assigned parties.
Please find enclosed, bulk sample analysis results, chain of custody documentation, as well as inspector(s) and laboratory certificate of accreditation. If you have any questions regarding this report, please do not hesitate to contact me at (480) 844-1710.
Sincerely, CONTINENTAL ENVIROTECH, INC.
Steven Chamberlain Field Services Manager
EMSL Analytical, Inc.
3356 West Catalina Drive, Phoenix, AZ 85017 Phone/Fax: (602) 276-4344 / (602) 276-4053 www.emsl.com phoenixlab@emsl.com
121204531 CustomerID: CONT60 CustomerPO:
ProjectID:
EMSL Order:
Attn: Steve Chamberlain Continental Envirotech, Inc.
3041 North Norfolk Street Suite 101 Mesa, AZ 85215-1147
Received: 10/04/12 11:20 AM
Bldg. 913
Fax: (480) 844-1752 Phone: (480) 844-1710
Project:
10/6/2012Analysis Date:
10/2/2012Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
121204531-0001
Battery Shop 6x6 Ceramic Tile / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0002
Battery Shop 6x6 Ceramic Tile / Brown
Brown None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0003
Battery Shop 6x6 Ceramic Tile / Brown
Brown None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0004
Grout Tan None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0005
Grout Tan None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0006
Grout Tan None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0007
Battery Shop 6x6 Ceramic Tile Floor / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0008
Battery Shop 6x6 Ceramic Tile Floor / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
1Test Report PLM-7.16.0 Printed: 10/8/2012 7:48:54 AM
Michelle Wilson, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Phoenix, AZ NVLAP Lab Code 200811-0, AZ0937
Initial report from 10/08/2012 07:48:54
Amanda Lang (1) Carlos Rivadeneyra (18)
Mike J. Williams (8) http://www.emsl.com mailto:phoenixlab@emsl.com
Phone/Fax: (602) 276-4344 / (602) 276-4053 www.emsl.com phoenixlab@emsl.com
121204531 CustomerID: CONT60 CustomerPO:
ProjectID:
EMSL Order:
Attn: Steve Chamberlain Continental Envirotech, Inc.
3041 North Norfolk Street Suite 101 Mesa, AZ 85215-1147
Received: 10/04/12 11:20 AM
Bldg. 913
Fax: (480) 844-1752 Phone: (480) 844-1710
Project:
10/6/2012Analysis Date:
10/2/2012Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
121204531-0009
Battery Shop 6x6 Ceramic Tile Floor / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0010
Grout Gray None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0011
Grout Gray/Tan None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0012
Grout Gray/Tan None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
13-Ceramic Tile
121204531-0013
Restroom 6x6 Tile / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
13-Thinset
121204531-0013A
Restroom 6x6 Tile / Brown
Gray None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
14-Ceramic Tile
121204531-0014
Restroom 6x6 Tile / Brown
Brown None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
14-Thinset
121204531-0014A
Restroom 6x6 Tile / Brown
Gray None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
2Test Report PLM-7.16.0 Printed: 10/8/2012 7:48:54 AM
Michelle Wilson, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Phoenix, AZ NVLAP Lab Code 200811-0, AZ0937
Initial report from 10/08/2012 07:48:54
Amanda Lang (1) Carlos Rivadeneyra (18)
Mike J. Williams (8)
Phone/Fax: (602) 276-4344 / (602) 276-4053 www.emsl.com phoenixlab@emsl.com
121204531 CustomerID: CONT60 CustomerPO:
ProjectID:
EMSL Order:
Attn: Steve Chamberlain Continental Envirotech, Inc.
3041 North Norfolk Street Suite 101 Mesa, AZ 85215-1147
Received: 10/04/12 11:20 AM
Bldg. 913
Fax: (480) 844-1752 Phone: (480) 844-1710
Project:
10/6/2012Analysis Date:
10/2/2012Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
121204531-0015
Restroom 6x6 Tile / Brown
Not Submitted
Empty sample bag.
121204531-0016
Grout White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0017
Grout White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0018
Grout Not Submitted
Empty sample bag.
121204531-0019
Restroom Wall 4x10 Tile
Tan None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0020
Restroom Wall 4x10 Tile
Tan None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0021
Restroom Wall 4x10 Tile
Brown/Tan None Detected Non-Fibrous Heterogeneous
Non-fibrous (other)100%
121204531-0022
Grout White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
3Test Report PLM-7.16.0 Printed: 10/8/2012 7:48:54 AM
Michelle Wilson, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Phoenix, AZ NVLAP Lab Code 200811-0, AZ0937
Initial report from 10/08/2012 07:48:54
Amanda Lang (1) Carlos Rivadeneyra (18)
Mike J. Williams (8)
Phone/Fax: (602) 276-4344 / (602) 276-4053 www.emsl.com phoenixlab@emsl.com
121204531 CustomerID: CONT60 CustomerPO:
ProjectID:
EMSL Order:
Attn: Steve Chamberlain Continental Envirotech, Inc.
3041 North Norfolk Street Suite 101 Mesa, AZ 85215-1147
Received: 10/04/12 11:20 AM
Bldg. 913
Fax: (480) 844-1752 Phone: (480) 844-1710
Project:
10/6/2012Analysis Date:
10/2/2012Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
121204531-0023
Grout White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0024
Grout White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0025
Fixture Caulking White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0026
Fixture Caulking White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
121204531-0027
Fixture Caulking White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
4THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.16.0 Printed: 10/8/2012 7:48:54 AM
Michelle Wilson, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Phoenix, AZ NVLAP Lab Code 200811-0, AZ0937
Initial report from 10/08/2012 07:48:54
Amanda Lang (1) Carlos Rivadeneyra (18)
Mike J. Williams (8)
HANGAR
TESTING
OFF2
TOIL1
MECH1
FIRST FLOOR
Exterior
STOR2
JW 1-3
DC 2-3
TC 3-3
JW 1-4
DC 2-4
TC 3-4
JW 1-5
DC 2-5
TC 3-5
JW 1-6
DC 2-6
TC 3-6
JW 1-7
DC 2-7
TC 3-7
CT 4-1
CT 4-2
CT 4-3
BA 5-1
BA 5-2
BA 5-3
FT 6-1
AD 7-1
FT 6-3
AD 7-3
FT 6-2
AD 7-2
FT 8-1
FT 8-2
FT 8-3
AD 9-1 5% CHR
AD 9-2 5% CHR
AD 9-3 5% CHR
BA 10-1
BA 10-2
BA 10-3
CT 11-1 CT 11-2
CT 11-3
CT 12-1
CT 12-2
CT 12-3
WP 13-1 3% CHR
WP 13-2 3% CHR
WP 13-3 3% CHR
PI 14-3 8% CHR
30 % AMO
PI 14-2 8% CHR
30% AMO
PI 14-1 8% CHR
30% AMO
WP 15-2
WP 15-3
WP 15-1
ASBESTOS BUILDING: 913
Nickolas.Durflinger Line
1 2
JW 1-1
DC 2-1
TC 3-1
JW 1-2
DC 2-2
TC 3-2
ASBESTOS BUILDING: 913
SECOND FLOOR
Nickolas.Durflinger Line
ROOF
ROOF 1 ROOF 2
ROOF 3
RM 16-1
RM 16-2
RM 16-3 RT 17-1 25% CHR
RT 17-2 25% CHR
RT 17-3 25% CHR
ASBESTOS: BUILDING 913
nv ir on om ic s, In c.
SCALE:
DATE:
PROJECT NO.:
DRAWN:
56 2 14 3
N O
D A T E
R E V I S I O N
A P P
Ph oe ni x, A ri zo na
1/1NTS
1/13/00
SAT
N th
S tr ee t, S te
A-
ASBESTOS-CONTAINING
MATERIAL and LEAD
PAINT SURVEYS
Building 926
Luke Air Force Base
14185 Falcon Street
Luke AFB, Arizona 85309
Prepared for:
Jacobs/Huitt-Zollars, JV
P.O. Box 709
Fort Worth, Texas 76101-0709
December 22, 2016
P.O. Box 969 Burleson, Texas 76097 | 817-447-0098 breitlingconsulting.com http://www.breitlingconsulting.com/
Breitling Consulting, LLC - i - Building 926, Luke AFB
TABLE OF CONTENTS
Page No.
1.0 Introduction
1.1 General Site Information
1.2 Purpose and Scope
1.3 Limitations
2.0 Limited Asbestos Survey
2.1 Visual Observations
2.2 Sampling Procedures
2.3 Laboratory Analysis
2.4 Sample Results
3.0 Limited Lead Paint Survey
3.1 Visual Observations
3.2 Sampling Procedures
3.3 Laboratory Analysis
3.4 Sample Results
4.0 Conclusions and Recommendations
4.1 Conclusions
4.2 Recommendations
Tables
Table 1: Summary of Asbestos-Containing Materials & Approximate Quantities
Table 2: Asbestos Laboratory Analytical Results
Table 3: Summary of Lead-Containing Paint Chip Samples
Table 4: Paint Chip Laboratory Analytical Results
Appendices
Appendix 1: Annotated Drawings
Appendix 2: Laboratory Reports and Chain-of-Custody Forms
Breitling Consulting, LLC - 1 - Building 926, Luke AFB
1.0 Introduction
Project scope and details were provided to Breitling Consulting, LLC (Breitling Consulting) by Jacobs/Huitt-Zollars, JV, as well as U.S. Army Corps of Engineers (USACE) and Luke Air Force Base (AFB) personnel.
Project Information Building 926 is an approximately 10,500 square-foot, metal-framed structure with slab-on-grade foundation constructed in 1975. The building functioned as storage space at the time of the survey. Building 926 is scheduled for demolition, which will include the abatement of asbestos-containing materials (ACM) and lead paint.
1.1 General Site Information
Site Name: Building 926, Luke AFB Site Location: 13970 W. Lighting Street, Luke AFB, Arizona 85309 Current Use: Storage Previous Use: Storage Year Built: 1975 Date of Site Visit: December 13, 2016 Assessor: Mr. Ronald Barnett
1.2 Purpose and Scope
The purpose of the pre-demolition inspection was to locate and identify suspect ACM and lead paint associated with the project.
1.3 Limitations
Breitling Consulting, in cooperation with Valley of the Sun Environmental Consultant, LLC (VSEC), has performed the ACM and lead paint assessment in accordance with generally accepted practices and procedures, in accordance with federal and state regulations, and in accordance with the scope of work under which the assessment is authorized. This report is covered by the limitations set forth in our proposal or this report, and any limitations encountered during the assessment. This report describes only the conditions present at the time of the assessment, in the areas assessed.
VSEC, on behalf of Breitling Consulting, collected samples of interior and exterior building materials considered to be suspect ACM, as well as interior and exterior painted surfaces.
Regardless of the thoroughness of surveys, the possibility exists that potential sources of ACM and lead paint may have escaped detection due to: (1) the limited scope of this assessment,
(2) the inaccuracy of records, interviews, work products or documents made available to Breitling Consulting or VSEC for this report, (3) the presence of undetected or unreported renovations and repairs, (4) inaccessible areas, and/or (5) deliberate concealment of detrimental information. The findings and opinions presented are relative to the dates of the site work and should not be relied on to represent conditions at substantially later dates due to changes in the condition of building materials over time, renovations, and repairs.
Breitling Consulting, LLC - 2 - Building 926, Luke AFB
This report is for the exclusive use of Jacobs/Huitt-Zollars, JV, USACE, Luke AFB and their agents, and use by any unauthorized parties in whole or in part, except as directed by legal jurisdiction, is at the sole risk of the user. If this assessment includes reliance on work products and/or documents prepared by others, Breitling Consulting has no responsibility for accuracy of information contained therein.
Breitling Consulting, LLC - 3 - Building 926, Luke AFB
2.0 Limited Asbestos Survey
The materials listed in Table 1 were identified as asbestos-containing.
Table 1: Summary of Asbestos-Containing Materials & Approximate Quantities
Sample ID Description Material Location Laboratory Results
Approximate Quantity
(Square Feet)
1A 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
5 1B 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
1C 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
3A Drywall & Joint
Compound / Texture Electrical Room, East Wall
2% - 3% Chrysotile (joint compound, texture)
ND - Drywall
3B Drywall & Joint
Compound / Texture Electrical Room, West Wall
2% - 3% Chrysotile (joint compound, texture)
ND - Drywall
3E Drywall & Joint
Compound / Texture Women’s Restroom, Wall
2% - Chrysotile (joint compound, texture)
ND - Drywall 1,000
15A Exterior – Window
Caulk South Side
5% - Chrysotile 10
15B Exterior – Window
Caulk 5% - Chrysotile 10
16A Exterior – Caulk Swamp Cooler Unit, Northeast Corner
8% - Chrysotile 10
16B Exterior – Caulk 10% - Chrysotile 10
18A Roof Penetration Sealant Roofing Presumed Positive 1,000 linear feet
2.1 Visual Observations
Suspect materials were grouped into homogeneous areas (areas uniform in color and texture) in accordance with federal asbestos sampling protocols in preparation for sampling. VSEC, on behalf of Breitling Consulting, collected samples in accordance with Environmental Protection Agency (EPA) National Emissions Standards for Hazardous Air Pollutants (NESHAP) requirements. Samples of the suspect materials were collected in accordance with the Asbestos Hazard Emergency Response ACT (AHERA), 40 CFR 763, Subpart E. Materials were collected in sufficient quantities to determine the potential asbestos content for each homogeneous area. In general, Breitling Consulting and VSEC considered the following materials to be non-suspect with regard to asbestos content unless observed conditions such as the presence of mastic, coating, or other suspect layer indicated otherwise: wood, glass, fiberglass, brick, bare concrete, unpainted concrete masonry unit (CMU), natural stone, ceramic tile, and bare metal.
2.2 Sampling Procedures
The pre-demolition asbestos survey was performed by Mr. Ronald Barnett (#G 4713). Mr.
Barnett is an EPA-certified Building Inspector for asbestos. The survey included visual observations, interviews with Mr. Robert Tetla III, Air Education and Training Command, identification of suspect ACM, bulk sampling of suspect ACM, and subsequent laboratory analysis of the samples for the detection of asbestiform minerals. Material samples were
Breitling Consulting, LLC - 4 - Building 926, Luke AFB sealed in airtight containers, documented on field data forms, and transported to the laboratory using appropriate chain-of-custody protocols to track handling of bulk samples.
VSEC, on behalf of Breitling Consulting, collected a total of 44 bulk samples of suspect ACM from Building 926. Annotated drawings showing approximate suspect ACM sample locations are in Appendix 1.
The roof of Building 926 was reported to be constructed of corrugated metal sheets without additional roofing materials such as asphalt, tar paper, shingles, etc. Please note that roofing penetration sealants were not sampled in order to maintain the current integrity of the roof. As a result, the roofing penetration sealants were presumed to be ACM for abatement and disposal purposes as there is a high likelihood that one or more of the penetration sealants would test positive (greater than 1% asbestos).
2.3 Laboratory Analysis
Samples were analyzed using Polarized Light Microscopy (PLM) with dispersion staining (DS), in accordance with the EPA Method for the Determination of Asbestos in Bulk Insulation Samples (Method 600/R-93/116). EMC Lab, Inc., an accredited environmental laboratory for lead and asbestos testing in Phoenix, Arizona, performed the analysis.
Federal regulations require that each layer of suspect material be analyzed separately for asbestos content. In addition, federal regulations state that if any sample from a homogeneous area contains asbestos, then the entire homogeneous area is considered asbestos-containing, regardless of the results from the remaining samples from that area. Therefore, samples for this project were analyzed on a positive stop basis, meaning that once a positive (greater than 1% asbestos) result is obtained, the remaining samples for that homogeneous area are not analyzed. Conversely, all the samples from a homogeneous area must be analyzed and found to contain less than 1% asbestos before that homogeneous area can be considered non-asbestos-containing.
2.4 Sample Results
The results of the sample analysis are presented in Table 2, and the laboratory analytical reports are in Appendix 2. Samples found to contain asbestos are presented in RED.
Table 2: Asbestos Laboratory Analytical Results
Sample ID Description Material Location Laboratory Results
1A 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
1B 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
1C 3” TSI – Elbow Electrical Room 60% - Chrysotile
ND - Wrap
2A 3” TSI – Pipe Run Electrical Room ND
2B 3” TSI – Pipe Run Electrical Room ND
2C 3” TSI – Pipe Run Electrical Room ND
3A Drywall & Joint Compound /
Texture Electrical Room, East Wall
2% - 3% Chrysotile (joint compound, texture)
ND - Drywall
Breitling Consulting, LLC - 5 - Building 926, Luke AFB
Sample ID Description Material Location Laboratory Results
3B Drywall & Joint Compound /
Texture Electrical Room, West
Wall
2% - 3% Chrysotile
(joint compound, texture) ND - Drywall
3C Drywall & Joint Compound Electrical Room, North
Wall
ND
3D Drywall & Joint Compound /
Wallpaper Weight Room, Wall ND
3E Drywall & Joint Compound /
Texture Women’s Restroom, Wall
2% - Chrysotile (joint compound, texture)
ND - Drywall
4A 4” Black Cove Base w/ Mastic Electrical Room ND
4B 4” Black Cove Base w/ Mastic Electrical Room ND
4C 4” Black Cove Base w/ Mastic Weight Room ND
5A Fiberglass & Wrap Electrical Room ND
5B Fiberglass & Wrap Electrical Room ND
5C Fiberglass & Ceiling Tile Weight Room ND
6A 2’ x 4’ White Pin Holes
Acoustical Ceiling Tiles Weight Room ND
6B 2’ x 4’ White Pin Holes Acoustical Ceiling Tiles
Weight Room ND
6C 2’ x 4’ White Pin Holes Acoustical Ceiling Tiles
Weight Room ND
7A 4” Brown Cove Base w/ Mastic Weight Room ND
7B 4” Brown Cove Base w/ Mastic Weight Room ND
8A Floor – Expansion Joint
Compound Throughout
ND
8B Floor – Expansion Joint
Compound Throughout
ND
8C Floor – Expansion Joint
Compound Throughout
ND
9A Concrete / Foundation East ND
9B Concrete / Foundation North ND
9C Concrete / Foundation Front of Women’s
Restroom
ND
10A 4” x 4” off-white Ceramic Tile /
Grout / Underlayment Women’s Restroom, Wall ND
10B 4” x 4” off-white Ceramic Tile /
Grout / Underlayment Women’s Restroom, Wall ND
11A 1” x 1” White Ceramic Tile /
Grout / Underlayment Women’s Restroom, Floor ND
11B 1” x 1” White Ceramic Tile /
Grout / Underlayment Women’s Restroom, Floor ND
12A 1” x 1” Beige Ceramic Tile / Grout
/ Underlayment Women’s Restroom, Floor ND
12B 1” x 1” Beige Ceramic Tile / Grout
/ Underlayment Women’s Restroom, Floor ND
13A 1” x 1” Brown Ceramic Tile /
Grout / Underlayment Women’s Restroom, Floor ND
13B 1” x 1” Brown Ceramic Tile /
Grout / Underlayment Women’s Restroom, Floor ND
14A Exterior – Door Caulk South Side ND
14B Exterior – Door Caulk South Side ND
15A Exterior – Window Caulk South Side 5% - Chrysotile
Breitling Consulting, LLC - 6 - Building 926, Luke AFB
Sample ID Description Material Location Laboratory Results
15B Exterior – Window Caulk South Side 5% - Chrysotile 16A Exterior – Caulk Swamp Cooler, NE Corner 8% - Chrysotile
16B Exterior – Caulk Swamp Cooler, NE Corner 10% - Chrysotile
17A Exterior – Caulk HVAC Exhaust Duct ND
17B Exterior - Caulk HVAC Exhaust Duct ND
18A Roof Penetration Sealant Roofing Presumed Positive ND = None Detected
Should materials other than those discussed in this report and listed in the summary tables be encountered, they should be treated as ACM until sampling can confirm the presence or absence of asbestos.
Breitling Consulting, LLC - 7 - Building 926, Luke AFB
3.0 Limited Lead Paint Survey
The coatings listed in Table 3 were identified as lead-containing.
Table 3: Summary of Lead-Containing Paint Chip Samples
Sample ID Description/Location Laboratory Results
(% by weight)
L4 Paint Chip – Women’s Restroom, Wall 0.026
L5 Ceramic Tile – 4”x4” – Women’s Restroom, Wall 0.107
3.1 Visual Observations
Multiple painted surfaces were observed on the exterior and interior of Building 926.
3.2 Sampling Procedures
The lead paint survey was performed by Mr. Ronald Barnett, licensed by the EPA as a Lead Inspector (#AZ-F159171-1). The survey included visual observations, interviews with Mr.
Robert Tetla III, Air Education and Training Command, identification of painted surfaces, collection of paint chip samples, and subsequent laboratory analysis of the paint chip samples.
Samples were sealed in airtight containers, documented on field data forms, and transported to the laboratory using appropriate chain-of-custody protocols to track handling of bulk samples.
VSEC, on behalf of Breitling Consulting, collected a total of nine paint chip samples from Building 926. Annotated drawings showing approximate paint chip sample locations are in Appendix 1.
3.3 Laboratory Analysis
Samples were analyzed using “flame atomic absorption, direct aspiration” per EPA SW-846 Method 7420. EMC Lab, Inc., an accredited environmental laboratory for lead and asbestos testing in Phoenix, Arizona, performed the analysis.
3.4 Sample Results
The results of the lead testing are in Table 4. Samples found to contain lead are in bold.
Table 4: Lead in Paint Chip Laboratory Analytical Results
Sample ID Description/Location Laboratory Results
(% by weight)
L1 Paint Chip – TSI 6” Electrical Room BRL
L2 Paint Chip – TSI 3” Electrical Room BRL
L3 Paint Chip – Weight Room BRL
L4 Paint Chip – Women’s Restroom, Wall 0.026
L5 Ceramic Tile – 4”x4” – Women’s Restroom, Wall 0.107
L6 Ceramic Tile 1”x1” – White – Women’s Restroom, Floor BRL
L7 Ceramic Tile 1”x1” – Beige – Women’s Restroom, Floor BRL
L8 Ceramic Tile 1”x1” – Lt. Beige – Women’s Restroom, Floor BRL
L9 Paint Chip – Exterior Wall – North BRL
BRL = Below Reportable Limits
Breitling Consulting, LLC - 8 - Building 926, Luke AFB
4.0 Conclusions and Recommendations
4.1 Conclusions
ACM Survey The results of the pre-demolition ACM survey indicate that the following materials were found to be asbestos-containing: joint compound, texture, thermal system insulation (TSI) (elbow), exterior – window caulk, exterior – swamp cooler caulk, and roof penetration sealant (presumed).
Building 926 is regulated under the following federal asbestos regulations:
40 CFR 61, Subpart M (Federal Asbestos NESHAP) 29 CFR 1926.1101 (Federal Occupational Safety and Health Administration (OSHA)
Construction Industry Standard)
Under these statutes, a building owner is required to abate (remove) all regulated ACM prior to performing demolition or renovation (including planned abatement activities) which might disturb asbestos materials. Regulated ACM (RACM) is defined by NESHAP to be “(a) friable asbestos material, (b) Category I non-friable ACM that has become friable, (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by NESHAP”.
Building 926 is also regulated under Maricopa County Air Pollution Control Regulations - Regulation III Rule 370, section 301.9 Subpart M. All activities must comply with required certification, training, record keeping, asbestos renovation and demolition standards outlined by the regulation.
Lead Paint Survey The results of the pre-demolition lead paint survey indicate that the following materials were found to be lead-containing: wall paint and ceramic tile located in the Women’s Restroom.
Based upon the readings, the paint chip samples collected contained less than 1.0 milligrams per square centimeter (mg/cm2) lead, and are therefore not defined as lead-based paint (LBP).
4.2 Recommendations
ACM Survey Breitling Consulting recommends the following regarding the asbestos results:
� Asbestos-containing wallboard systems in the bathrooms, electrical room, TSI (elbow) in electrical room, and roof penetration sealants should be abated by a qualified abatement contractor prior to initiation of demolition/renovation activities.
Breitling Consulting recommends that the contractor be a state-licensed asbestos abatement contractor.
� In the event that demolition/renovation activities identify additional suspect ACM, a licensed asbestos inspector should be contacted to perform additional sampling activities.
Breitling Consulting, LLC - 9 - Building 926, Luke AFB
Lead Paint Survey Based upon the paint chip samples analytical results, all samples collected were below the EPA LBP limit with a total lead content less than 1.0 mg/cm2. According to Housing and Urban Development Department (HUD) Lead-Based Paint Interim Guidelines for Hazard Identification and EPA Lead-Based Paint in Target Housing and Child Occupied Facilities (40 CFR Part 745), the definition of LBP is paint which has a lead content greater than or equal to 5,000 milligrams per kilogram (mg/kg) (0.5% by weight) or greater, or 1.0 mg/cm2 which applies to target housing and child occupied facilities. HUD guidelines define target housing as “any housing constructed prior to 1978, except housing for the elderly or persons with disabilities (unless any child who is six years of age or younger resides or is expected to reside in such housing) or any zero-bedroom dwelling” and child-occupied facility as “a building or part of a building constructed before 1978, including but not limited to, a day-care center, preschool, or kindergarten classroom, that is visited regularly by the same child, six years of age or younger, at least two days in any calendar week if the visits are for at least three hours each day and 60 hours each year.”
At this time, the above referenced HUD regulations do not apply to Building 926 because it does not meet either the definition of target housing or of a child-occupied facility. There are currently no federal or state regulations requiring abatement of lead paint in buildings which are not considered to be target housing or child occupied facilities; however, state and federal disposal requirements apply to all demolished structures that include lead paint components.
It should be noted that the OSHA Construction Industry Standard, 29 CRF, 1926.62 does apply to any employee involved with demolition/renovation work that might occur in the above building. The Construction Industry Standard regulates occupational exposures to airborne lead, which includes demolition or salvage of structures where lead or materials containing lead are present, and any amount of lead present in painted surfaces, including those which fall below the above definition of lead-based paint, could result in regulated occupational exposures. They should therefore be monitored according to 29 CFR, 1926.62 whenever they are disturbed in a manner that could result in exposure to airborne lead particulates. It is the responsibility of the employer to comply with 29 CFR, 1926.62 to protect the safety and health of his/her employees involved in the demolition or renovation of the above structure. According to OSHA, the Permissible Exposure Limit (PEL) for lead is 50 micrograms per cubic meter (µg/m3) (8-hour Time Weighted Average (TWA)) with an action limit of 30 µg/m3 (8-hour TWA).
Federal employees who are not subject to 29 CFR, 1926.62 (non-construction/demolition related work) are subject to the OSHA General Industry Standard, 29 CFR, 1910.1025. This standard was promulgated by OSHA to protect workers who could potentially be exposed to inorganic lead, including metallic lead, all inorganic compounds, and organic lead soaps.
Again, the occupational exposure to inorganic lead is to be limited to 50 µg/m3 (8-hour TWA).
Breitling Consulting, LLC Building 926, Luke AFB
Appendix 1: Annotated Drawings
3 4
3D; 4C; 5C; 6; 7
N Not to Scale
Asbestos Sample Locations Building 926
Luke AFB
3E; 10A; 11; 12; 13
1; 2; 3A/B/C;
4A/B; 5A/B
Electrical Room
Weight Room
Women's RR Men's RR
8A
9B
8B
8C
9A
9C
10B
14Red Denotes Positive for Asbestos Content
Roof Penetration Sealant Presumed Positive for Asbestos Content
3 4
L3
N Not to Scale
Lead Paint Sample Locations Building 926
Luke AFB
L9
L4, L5, L6, L7, L8
L1, L2 Electrical Room
Weight Room
Women's RR Men's RR
Breitling Consulting, LLC Building 926, Luke AFB
Appendix 2: Laboratory Reports and Chain-of-Custody Forms
Asbestos Detected
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Cellulose FiberYesLAYER 1 3" TSI Elbow, Lt. Gray
Chrysotile0179476-001 ELECTRICAL RM 121316-1A
60% 5%
Gypsum Carbonates Quartz Binder/Filler
35%
Cellulose FiberNoLAYER 2 3" TSI Elbow Wrap, Off White/ White
None Detected 70%
Carbonates
30%
Cellulose FiberNoLAYER 3 3" TSI Elbow Wrap, Off White/ White
None Detected 85%
15%
Cellulose FiberYesLAYER 1 3" TSI Elbow, Lt. Gray
Chrysotile0179476-002 ELECTRICAL RM 121316-1B
60% 5%
Gypsum Carbonates
3" TSI Elbow Wrap, Off White/ White
None Detected 70%
3" TSI Elbow Wrap, Off White/ White
None Detected 85%
Cellulose FiberYesLAYER 1 3" TSI Elbow, Lt. Gray
Chrysotile0179476-003 ELECTRICAL RM 121316-1C
60% 5%
Gypsum Carbonates
3" TSI Elbow Wrap, Off White/ White
None Detected 85%
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Fibrous GlassNoLAYER 1 3" TSI Pipe Run, Yellow
None Detected0179476-004 ELECTRICAL RM 121316-2A
95%
Gypsum
5%
Cellulose Fiber Fibrous Glass
NoLAYER 2 3" TSI Pipe Run Wrap, Yellow/ Beige/ Tan/ Silver
None Detected 50% 10%
Aluminum
40%
Fibrous Glass Cellulose Fiber
NoLAYER 1 3" TSI Pipe Run, Yellow
None Detected0179476-005 ELECTRICAL RM 121316-2B
95% 1%
4%
3" TSI Pipe Run Wrap, Yellow/ Beige/ Tan/ Silver
None Detected 60%
Aluminum
Fibrous GlassNoLAYER 1 3" TSI Pipe Run, Yellow
None Detected0179476-006 ELECTRICAL RM 121316-2C
95%
Fibrous Glass
NoLAYER 2 3" TSI Pipe Run Wrap, Yellow/ Beige/ Tan/ Silver
None Detected 50% 10%
Aluminum
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Cellulose FiberNoLAYER 1 Drywall, White/ Brown
None Detected0179476-007 ELECTRICAL RM-
EAST WALL121316-3A
12%
Gypsum Carbonates Mica
88%
Cellulose FiberYesLAYER 2 Joint Compound, White
Chrysotile 2% 2%
Carbonates
96%
YesLAYER 3 Texture / Paint, White/ Off White
Chrysotile 3%
Carbonates Mica
97%
Cellulose FiberNoLAYER 1 Drywall, White/ Brown
None Detected0179476-008 ELECTRICAL RM-
WEST WALL121316-3B
12%
Gypsum Carbonates
Joint Compound, White
Chrysotile 2% 1%
Carbonates
YesLAYER 3 Texture / Paint, White/ Off White
Chrysotile 3%
Carbonates Mica
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Cellulose FiberNoLAYER 1 Drywall, White/ Brown
None Detected0179476-009 ELECTRICAL RM-
NORTH WALL121316-3C
12%
Gypsum Carbonates
Joint Compound, White/ Off White
None Detected 2%
Carbonates Perlite
98%
Cellulose FiberNoLAYER 1 Drywall, White/ Brown
None Detected0179476-010 WEIGHT RM-WALL 121316-3D
12%
Gypsum Carbonates
Joint Compound, White
None Detected 3%
Carbonates
Wall Paper, White
None Detected 40%
Carbonates
60%
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Cellulose FiberNoLAYER 1 Drywall, White/ Brown
None Detected0179476-011 WOMEN'S RR-WALL 121316-3E
12%
Gypsum Carbonates
Joint Compound, White
Chrysotile 2% 2%
Carbonates
96%
Cellulose FiberYesLAYER 3 Texture / Paint, White/ Off White
Chrysotile 2% 1%
Carbonates Mica
NoLAYER 1 4" Cove Base, Black/ Brown
None Detected0179476-012 ELECTRICAL RM 121316-4A Carbonates
100%
Mastic, Brown
None Detected 3%
Quartz
4" Cove Base, Black/ Brown
None Detected0179476-013 ELECTRICAL RM 121316-4B Carbonates
Mastic, Brown
None Detected 1%
Quartz
99%
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
NoLAYER 1 4" Cove Base, Black
None Detected0179476-014 WEIGHT RM 121316-4C Carbonates
Binder/Filler
100%
Cellulose FiberNoLAYER 2 Mastic, Yellow
None Detected 1%
Quartz
Mastic, Brown
None Detected 3%
Quartz
Fibrous Glass Cellulose Fiber
NoLAYER 1 Fiberglass, Yellow
None Detected0179476-015 ELECTRICAL RM-
WALL121316-5A
95% 1%
4%
Fibrous GlassNoLAYER 2 Fiberglass Wrap, White/ Silver
None Detected 70%
Aluminum
Fibrous GlassNoLAYER 1 Fiberglass, Yellow
None Detected0179476-016 ELECTRICAL RM-
WALL121316-5B
95%
Fibrous GlassNoLAYER 2 Fiberglass Wrap, White/ Silver
None Detected 70%
Aluminum
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
Fibrous Glass Cellulose Fiber
NoLAYER 1 Fiberglass, Pink
None Detected0179476-017 WEIGHT RM 121316-5C
95% 2%
3%
Mineral Wool
NoLAYER 2 Ceiling Tile, Beige
None Detected 40% 40%
Carbonates Perlite
20%
Mineral Wool
No2'x4' Acoustical Ceiling Tile, White/ Beige
None Detected0179476-018 WEIGHT RM 121316-6A
40% 40%
Carbonates
Mineral Wool
No2'x4' Acoustical Ceiling Tile, White/ Beige
None Detected0179476-019 WEIGHT RM 121316-6B
40% 40%
Carbonates
Mineral Wool
No2'x4' Acoustical Ceiling Tile, White/ Beige
None Detected0179476-020 WEIGHT RM 121316-6C
40% 40%
Carbonates
4" Cove Base, Brown
None Detected0179476-021 WEIGHT RM 121316-7A Carbonates
Wollastonite Cellulose Fiber
NoLAYER 2 Mastic, Brown
None Detected 5% 1%
Quartz
94%
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016 EPA Method: Project Name: LUKE AIR FORCE BASE BLDG 926 Submitted By: RON BARNETTAddress:
Collected By:
9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726
12/14/2016Date Reported:
EPA 600/R-93/116
Asbestos Type
NoLAYER 1 4" Cove Base, Brown
None Detected0179476-022 WEIGHT RM 121316-7B Carbonates
Wollastonite Cellulose Fiber
NoLAYER 2 Mastic, Brown
None Detected 5% 2%
Quartz
93%
Cellulose FiberNoExpansion Compound, Black None Detected0179476-023 THROUGHOUT 121316-8A
1%
Carbonates
Cellulose FiberNoExpansion Compound, Black None Detected0179476-024 THROUGHOUT 121316-8B
<1%
Carbonates
Cellulose FiberNoExpansion Compound, Black None Detected0179476-025 THROUGHOUT 121316-8C
1%
Carbonates
Cellulose FiberNoFoundation, Gray None Detected0179476-026 EAST 121316-9A
<1%
Gypsum Quartz Carbonates
Layer Name / Sample Description
Lab ID Sample Location
Bulk Asbestos Analysis by Polarized Light Microscopy
Non-Asbestos Constituents
Laboratory Report
0179476
NVLAP#101926-0
Client ID
Client:
Address: 870 E. GARY DR.
CHANDLER AZ 85225
VSEC
Date Received: 12/13/2016
12/14/2016Date Analyzed:
Job# / P.O. #:
EMC LABS, INC.
Collected: 12/13/2016…