ATTACHMENT I

DESIGN-BUILD REQUEST FOR PROPOSAL

PERMITS/AUTHORITY TO CONSTRUCT CHECKLIST ATTACHMENT I

Enclosure 3: PERMITS/AUTHORITY TO CONSTRUCT CHECKLIST This checklist is provided as a reference and as a planning and preparatory tool. The Contractor shall be responsible for obtaining all permits required by the contract and required by federal, state, and local governments and Creech/Nellis AFB.

PERMIT/AUTHORITY TO

CONSTRUCT

RESPONSIBLE PARTY TO

OBTAIN PERMIT

PERMITTING AGENGY

Clark County Dust Permit Contractor

Clark County Department of Air Quality and Environmental Management

Trench over 100 feet long and two feet deep?

Contractor

Over ¼ acre disturbed (10,890 sq.

ft.)

Storm Water Discharge Permit

(NPDES)

Contractor Clark County, NV or Nevada Department of Environmental Protection

Authority to Construct (ATC) Required prior to commencing construction

Contractor Clark County Department of Air Quality and Environmental Management

a. Boilers Contractor

b. Cooling Towers (open drift) Contractor

c. Cyclones Contractor

d. Fuel Burning Equipment Contractor

e. Fuel Dispensing Equipment Contractor

f. Fuel Storage Tanks Contractor

g. Screens (gravel) Contractor

h. Asphalt Batch Plant Contractor

i. Rock Crusher Contractor

j. Quarry (Borrow Pit) Contractor

k. Paint Booths Contractor

l. Water Heaters Contractor

m. Generators Contractor

Asbestos

a. ACM Survey Contractor

b. Demolition Permit Contractor

Lead Based Paint

a. LBP Survey Contractor

b. Demolition Permit Contractor

PCB

Contractor Clark County, NV or Nevada Department of Environmental Protection

Back Flow Prevention Contractor Sewerage System

a. Food Preparation Greasetraps Contractor

b. Septic System (permit) Contractor Plants and Landscaping Contractor Refrigerants and other Ozone Depleting Chemicals

Contractor Clark County, NV or Nevada Department of Environmental Protection

Landfills Contractor Hazardous Materials

Contractor Clark County, NV or Nevada Department of Environmental Protection

Sprinkler Systems Contractor Automated Fire Fighting Foam (AFFF) Systems

Recycled Materials Contractor

Restoration Sites Contractor Historical and Archaeological Sites (Cultural Resources)

Contractor

Presence of Protected Plant and Animal Species

Contractor

Presence or Creation of a Wetland Contractor Radon Contractor AICUZ Contractor Electromagnetic Fields Contractor Drinking Water Sources (Wellhead Protection)

Contractor

Burn Permit/Welding Permit Contractor Nellis AFB Digging Permits Contractor Nellis AFB

ATTACHMENT J

INDIVIDUAL SPACE CRITERIA DATA SHEETS ATTACHMENT J

INDIVIDUAL SPACE CRITERIA DATA SHEET

Space: Main Entry

Size (s.m.): 79 SF Occupancy: Assembly: 15/p = 5 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: Densified, polished concrete

Walls: Painted Gypsum board, rubber base

Ceiling: Acoustic ceiling

Clear Ceiling Height:

Windows: Hollow and clerestory

Doors: Aluminum full lite

Adjacencies: Dining, Serving line

Features:

Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade

Walls: Nonbearing metal stud walls

Ceiling: 2x4 suspended metal grid

HVAC:

Heating: � Air Conditioning � Ventilation �

Temperature:

Special Requirements:

PLUMBING:

Fixtures:

Shop Air: � Equipment Air: � Floor Drains: �

Natural Gas: � Other:

FIRE PROTECTION:

System Type: Automatic Fire protection – sprinkler system

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: �

Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Other:

GFGI:

Space: Entry Hall

Size (s.m.): 850 SF Occupancy: Assembly: 15/p= 57 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum Board, rubber base Ceiling: acoustic ceiling Clear Ceiling Height: 15’-0” Windows: N/A Doors: Hollow Metal Adjacencies:

Features:

Furnishings: Coat and Hat Racks

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud wall Ceiling: 2x4 Suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per Base Design Guidelines Special Requirements:

PLUMBING:

Fixtures: Hi-low Water cooler

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Per Base Design Guidelines

Special Requirements:

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

OTHER COMMENTS:

Provide convenience power and power for high-low water cooler

Space: Dining Room

Size (s.m.): 3218/4695/6092 SF Occupancy: Assembly: 15/p =215/313/406 Function: Dining Room

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Acoustic 2x4 “Second Look” Clear Ceiling Height: +15’-0” Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Serving Line, Entry Features:

Furnishings:

STRUCTURAL:

Floor: concrete slab on engineered grade Walls: metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed 2x4 prismatic

Special Requirements: Provide power and data to accommodate GFGI TVs and convenience power Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

GFGI: 32 Booths, 78 Tables, 312 Chairs and 3 Flat Screen TV’s hanging from ceiling

Size varies per Base bid/Option 1/Option 2

Space: Option 4 Dining

Size (s.m.): 2356 SF Occupancy: Assembly: 15/p = 157 Function: Semi-Private Dining area Note: Space already counted in “Dining Room”

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum board Ceiling: “Second Look” acoustic tile Clear Ceiling Height: 15’-0” AFF Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Dining Features: Full height walls with doors to main dining area, folding partition to further segregate room Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud; hot rolled steel tube exterior with metal siding Ceiling: 2x4 Suspended metal frames Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements:

Security:

Light Level: Per UFC requirements

EQUIPMENT:

Cranes/Hoists:

Other: Tables and chairs from “Dining room,” 3 ceiling mounted flat screen TVs

Provide convenience outlets and power at ceiling for TVs

Space: Serving

Size (s.m.): 1971 Occupancy: Assembly:15/p = 132 Function: Feeding queue

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies: Main Entry, Checkouts Features:

Furnishings:

STRUCTURAL:

Floor: concrete slab on engineered grade Walls: Nonbearing metal stud walls;

Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures:

Natural Gas: � Other: Floor sinks as required for equipment

Hazard Class:

Detection:

ELECTRICAL:

Telephone: X� LAN: X� PA: � Lighting Recessed prismatic

Power Provide convenience outlets and floor outlets for equipment

Space: Kitchen Prep

Size (s.m.): 1925 Occupancy: Factory: 200/p= 10 Function: Food Preparation Kitchen

ARCHITECTURAL:

Finishes:

Floor: High friction ceramic tile Walls: Painted Gypsum board, rubber base Ceiling: food service grade acoustic Clear Ceiling Height:

Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Serving Line, Food Storage Features: FRP or other moisture and impact guard on Walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: _x__- Sinks, ___-Floor Sinks, ___-floor drains

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements:

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Other: See drawing and specifications for Food Service equipment

Provide convenience outlets and power for equipment

Space: Kitchen Hall

Size (s.m.): 395 SF Occupancy: Factory: 200/p = 2 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: High friction ceramic tile Walls: Painted Gypsum board, tile base Ceiling: Food Service grade acoustic ceiling Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies:

Features: FRP or other impact resistant guard on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: As required per UFC Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets Security: As required per FUC Light Level:

EQUIPMENT:

Cranes/Hoists:

Space: Dining Janitor Closet

Size (s.m.): 49 SF Occupancy: Utility: 300/p =1 Function: Janitor Closet

Floor: Sealed concrete

Walls: Painted Gypsum Board

Ceiling: Acoustic moisture resistant

Clear Ceiling Height:

Windows: N/A

Doors: Hollow Metal

Adjacencies: Dining, restrooms

Features: Wainscoting – FRP all walls

Walls: Nonbearing metal stud walls

Fixtures: Mop Sink

Lighting:

Special Requirements: Provide ceiling or wall mounted power at 48” AFF

Space: Restrooms

Size (s.m.): 420 SF Occupancy: Utility: 300/p = 2 Function: M/F Public Restrooms

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, sealed, polished concrete Walls: Painted Gypsum board Ceiling: Acoustic moisture resistant Clear Ceiling Height:

Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Dining Area Features: Wainscoting- FRP or other moisture and impact resistant guard on all walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade with applied hardener Walls: Nonbearingmetal stud wall Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per Base Design Guidelines Special Requirements:

PLUMBING:

Fixtures: 2 Lavatories, (2M,3W) water closets, (3M,4W), urinals (2M)

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed fixtures prismatic

Special Requirements: Provide convenience outlets Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Other: Soap dispensers, paper towel dispensers, and garbage can per base design guidelines

Space: Staff Hall

Size (s.m.): 137 SF Occupancy: Business: 100/p =1 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: High-friction ceramic tile Walls: Painted Gypsum board, rubber base Ceiling: food service grade acoustic ceiling Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies:

Features: FRP or other impact resistant guard on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: As required for UFC Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Provide full height metal lockers on wall opposite Office/Training

Space: Service Hall

Size (s.m.): 261 SF Occupancy: Factory: 100/p = 2 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: High friction ceramic tile in kitchen area/densified, polished concrete in public area Walls: Painted Gypsum board, tile base Ceiling: Food Service grade acoustic ceiling Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies:

Features: FRP or other impact resistant guard on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Space: Food Storage

Size (s.m.): 1307 SF Occupancy: Storage: 300/p=4 Function: Food Storage room

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum Board, rubber base Ceiling: Food Grade acoustic Clear Ceiling Height: +12’-0” AFF Windows: Hollow metal clerestory Doors: Hollow Metal or FRP Adjacencies: Receiving, Food Prep Kitchen Features: FRP or other moisture and impact guard on walls, built- walk in freezers, refrigerators Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures:

Hazard Class:

Detection:

ELECTRICAL:

Telephone: X� LAN: X� PA: � Lighting:

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Other: Desk, w/drawers overhead storage, computer, printer, floor scale, 60 mobile shelves 10 dry storage #10 can racks, 2 self contained refrigerator unit, phone, jack pallet

Provide convenience outlets and power for equipment

Space: Dishwashing Room

Size (s.m.): 759 SF Occupancy: Factory: 200/p= 4 Function: Dish and Pot washing

ARCHITECTURAL:

Finishes:

Floor: high friction ceramic tile Walls: Painted Gypsum Board at 8’, FRP to 8’ AFF Ceiling: Food service grade acoustic Clear Ceiling Height: 12’ Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Dining Room, serving line Features: FRP or other moisture resistant guard on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding Ceiling: 2x4 Suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures:

Natural Gas: � Other: Water supply and sanitary sewer as required for equipment

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements: As required for equipment Security:

Light Level: Per UFC requirements

EQUIPMENT:

Other:: Clipper/dishwaser w/counter and sink with sprayer, 4 metal shelves, 45 clipper racks, : 4 busing cart, 7 floor pan shelves, See drawing for complete equipment schedule

Space: General Storage

Size (s.m.): 43 SF Occupancy: Storage: 300/p= 1 Function: Stock Room

Floor: Densified, stained, polished concrete

Walls: Painted Gypsum board, rubber base

Ceiling: Food service grade acoustic

Clear Ceiling Height:

Windows: N/A

Doors: Hollow Metal

Adjacencies: Electrical Room

Features: 5/8” Fire-resistant Plywood on Walls

Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding

Fixtures: N/A

Telephone: X� LAN: X� PA: �

Lighting:

Special Requirements:

Provide convenience outlets

Space: Refuse and Recycling

Size (s.m.): 185 SF Occupancy: Storage: 300/p= 1 Function: Storage Room

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food Service grade acoustic Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies: Kitchen, Loading Dock Furnishings: FRP or other impact resistant surface on walls

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements:

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Space: Training Room

Size (s.m.): 275 SF Occupancy: Assembly: 15/p= 18 Function: Training- Conference- Break Room

Floor: Densified, stained, polished concrete

Walls: Painted gypsum board, rubber base

Ceiling: Acoustic – food service grade

Clear Ceiling Height: +10’-0” AFF

Windows: Hollow Metal

Doors: Hollow Metal

Adjacencies: Office, Kitchen

Floor: concrete slab on engineered grade

Walls: Nonbearing metal stud walls (Int.), PEMB w/metal stud framing on interior face

Temperature: Per Base Design Guidelines

Lighting: Recessed 2x4 direct/indirect

Special Requirements: Provide power and data to accommodate equipment listed below

Light Level: Per Base Design Guidelines

Cranes/Hoists: N/A

Other: conference room table w/chairs, 2 computers, 1 printer, 1 copier, 3 book shelves, GFGI: 1 phone, 2 small computer desks w/chairs, projector w/projection screen

Space: Office

Size (s.m.): 206 SF Occupancy: Utility:100/p = 2 Function: Office

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, and polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food service grade acoustic Clear Ceiling Height:

Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Food Prep, Training Features:

Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed direct/indirect

Special Requirements: Provide power for equipment noted below Security:

Light Level: Per Base Design Guidelines

EQUIPMENT:

Cranes/Hoists:

Other: 2 desks, safe, 2 computers, 1 printer, 2 book shelves, 2 filing cabinets, 2 phones, 1 fax

Space: Closet

Size (s.m.): 52 Occupancy: Storage: 300/p=1 Function: Stock Room / area

Floor: Densified, stained, polished concrete

Walls: Painted Gypsum board, rubber base

Ceiling: Food service grade acoustic

Clear Ceiling Height:

Windows: N/A

Doors: Hollow Metal

Adjacencies: Kitchen Toilets

Features: 5/8” Fire Resistant Plywood on Walls

Walls: Nonbering metal stud walls; hot rolled steel tube exterior with metal siding

Temperature: As required per code

Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets

Space: Exit Hall

Size (s.m.): 122 SF Occupancy: Business: 100/p=1 Function: Circulation

ARCHITECTURAL:

Finishes:

Floor: High-friction ceramic tile Walls: Painted Gypsum board Ceiling: food service grade acoustic ceiling Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies: Offices Features: FRP or other impact resistant guard on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 Suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: Hi-low Water cooler

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets and power for water cooler Security:

Light Level: As required per code

EQUIPMENT:

Cranes/Hoists:

Space: Receiving

Size (s.m.): 70 SF Occupancy: Business: 100/p = 1 Function: Stock receiving

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food Service grade acoustic Clear Ceiling Height: 12’-0” Windows: Hollow metal view window to dock Doors: Hollow Metal Adjacencies: Dock, Food Storage Features: Wall guards Furnishings:

STRUCTURAL:

Floor: concrete slab on engineered grade Walls: metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Recessed prismatic

Special Requirements: Provide convenience outlets and power for equipment per Base Design Guidelines Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

GFGI: Coat rack, small desk, 3 dollies

Space: Mechanical

Size (s.m.): 861 SF Occupancy: Utility:300/p = 3 Function: Mechanical Equipment

ARCHITECTURAL:

Finishes:

Floor: Sealed Concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies: Electrical Room Features: 5/8” Fire-resistant Plywood on Walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Load bearing metal stud walls; hot rolled steel tube exterior with metal siding Ceiling: N/A Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: As required per UFC Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Suspended from structure

Special Requirements: Provide power as required for equipment and service Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Provide access ladder and roof/hatch to mechanical well at roof

Space: Communications Room

Size (s.m.): 68 SF Occupancy: Utility: 300/p =1 Function: Telephone and Data

ARCHITECTURAL:

Finishes:

Floor: Densified, stained, polished Concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies: Electrical Room Features: Fire rated ¾” Plywood on walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls; hot rolled steel tube exterior with metal siding Ceiling: N/A Open to deck Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements:

Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Space: Kitchen Janitor Closet

Size (s.m.): 69 SF Occupancy: Utility: 300/p= 1 Function: Janitor Closet

ARCHITECTURAL:

Finishes:

Floor: Sealed concrete Walls: Painted Gypsum board Ceiling: Acoustic moisture resistant Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies: Offices Features: Wainscoting – FRP all walls Furnishings:

STRUCTURAL:

Floor: concrete slab on engineered grade Walls: nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: Mop Sink

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting: Ceiling or wall mounted

Special Requirements: Provide power at 48” AFF Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Space: Toilets

Size (s.m.): 136 (combined) SF Occupancy: Utility:300/p :1Function: M/F Staff Restrooms

Floor: Densified, stained, polished concrete

Walls: Painted Gypsum Board

Ceiling: Acoustic moisture resistant

Clear Ceiling Height: +10’-0”

Windows: N/A

Doors: Hollow Metal

Adjacencies: Offices, Kitchen

Features: FRP Wainscoting at all walls

Floor: concrete slab on engineered grade

Walls: Nonbearing metal stud walls (int.)

Temperature: Per Base Design Standards

Fixtures: Ultra High-Efficiency Lavatory, water closet (toilet)

Lighting: Recessed 2x4 prismatic

Special Requirements:

Light Level: Per Base Design Guidelines

Other: Paper towel dispenser, soap dispenser, trash receptacle, etc. per Base Design Guidelines

Space: Electrical Room

Size (s.m.): 166 SF Occupancy: Utility:300/p= 1 Function: Electrical Equipment Room

ARCHITECTURAL:

Finishes:

Floor: Sealed concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:

Windows: N/A Doors: Hollow Metal Adjacencies: Comm. Room Features: ¾” Fire-Resistant Plywood on Walls Furnishings:

STRUCTURAL:

Floor: Concrete slab on engineered grade Walls: PEMB frame, nonbearing/metal stud walls (interior) Ceiling: N/A Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures:

System Type:

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements: Provide power and data as required for electrical equipment Security:

Light Level: As required by UFCs

EQUIPMENT:

Cranes/Hoists:

Space: Loading Dock

Size (s.m.): 466 SF (233 effective size) Occupancy: Exterior Utility:300/p = 1Function: Loading area

ARCHITECTURAL:

Finishes:

Floor: Sealed concrete Walls: hot rolled steel tube exterior with metal siding Ceiling: hot rolled steel tube exterior with metal siding Clear Ceiling Height:

Windows: Hollow metal view window Doors: Hollow Metal Adjacencies: Mechanical, Receiving, Food Storage Features: Capability for 48” high truck bed loading/unloading Furnishings:

STRUCTURAL:

Floor: concrete slab on engineered grade Walls: Metal framing; hot rolled steel tube exterior with metal siding Ceiling:

Features:

HVAC:

Heating: � Air Conditioning � Ventilation � Temperature:

Special Requirements:

PLUMBING:

Fixtures: N/A

Hazard Class:

Detection:

ELECTRICAL:

Telephone: � LAN: � PA: � Lighting:

Special Requirements: Intercom Security:

Light Level:

EQUIPMENT:

Cranes/Hoists:

Hydraulic dock leveler may be used in lieu of, or in combination with, recessed dock to provide 48” dock height capability.

ATTACHMENT K

GEOTECHNICAL REPORT ATTACHMENT K

Attachment I
Attachment J
Attachment K

File details come from the government source that posted it. Updated .