08_Attach_I_thru_K.PDF
PDF 1 MB Posted
- Attached to
- Design-Build Unmanned Aerial Systems (UAS) Dining Facility, Creech Air Force Base, Nevada
- Solicitation number
- W912PL-09-R-0004
About this file
Attachments I thru K
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AM04_Specs.pdf | ||
| AM04_Drawings.pdf | ||
| Amendment 0003.pdf | ||
| Am2.pdf | ||
| Amendment 0001.pdf | ||
| 01_TOC.pdf | ||
| 05_Attach B.pdf | ||
| 00_Division_0.PDF | ||
| 04_Attach A.pdf | ||
| 07_Attach_H.pdf | ||
| 03_Section 2 - General Tech Specs.pdf | ||
| 06_Attach_C_thru_G.PDF | ||
| 02_Section 1 - Drawings Rev.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT I
DESIGN-BUILD REQUEST FOR PROPOSAL
PERMITS/AUTHORITY TO CONSTRUCT CHECKLIST ATTACHMENT I
Enclosure 3: PERMITS/AUTHORITY TO CONSTRUCT CHECKLIST This checklist is provided as a reference and as a planning and preparatory tool. The Contractor shall be responsible for obtaining all permits required by the contract and required by federal, state, and local governments and Creech/Nellis AFB.
PERMIT/AUTHORITY TO
CONSTRUCT
RESPONSIBLE PARTY TO
OBTAIN PERMIT
PERMITTING AGENGY
Clark County Dust Permit Contractor
Clark County Department of Air Quality and Environmental Management
Trench over 100 feet long and two feet deep?
Contractor
Over ¼ acre disturbed (10,890 sq.
ft.)
Storm Water Discharge Permit
(NPDES)
Contractor Clark County, NV or Nevada Department of Environmental Protection
Authority to Construct (ATC) Required prior to commencing construction
Contractor Clark County Department of Air Quality and Environmental Management
a. Boilers Contractor
b. Cooling Towers (open drift) Contractor
c. Cyclones Contractor
d. Fuel Burning Equipment Contractor
e. Fuel Dispensing Equipment Contractor
f. Fuel Storage Tanks Contractor
g. Screens (gravel) Contractor
h. Asphalt Batch Plant Contractor
i. Rock Crusher Contractor
j. Quarry (Borrow Pit) Contractor
k. Paint Booths Contractor
l. Water Heaters Contractor
m. Generators Contractor
Asbestos
a. ACM Survey Contractor
b. Demolition Permit Contractor
Lead Based Paint
a. LBP Survey Contractor
b. Demolition Permit Contractor
PCB
Contractor Clark County, NV or Nevada Department of Environmental Protection
Back Flow Prevention Contractor Sewerage System
a. Food Preparation Greasetraps Contractor
b. Septic System (permit) Contractor Plants and Landscaping Contractor Refrigerants and other Ozone Depleting Chemicals
Contractor Clark County, NV or Nevada Department of Environmental Protection
Landfills Contractor Hazardous Materials
Contractor Clark County, NV or Nevada Department of Environmental Protection
Sprinkler Systems Contractor Automated Fire Fighting Foam (AFFF) Systems
Recycled Materials Contractor
Restoration Sites Contractor Historical and Archaeological Sites (Cultural Resources)
Contractor
Presence of Protected Plant and Animal Species
Contractor
Presence or Creation of a Wetland Contractor Radon Contractor AICUZ Contractor Electromagnetic Fields Contractor Drinking Water Sources (Wellhead Protection)
Contractor
Burn Permit/Welding Permit Contractor Nellis AFB Digging Permits Contractor Nellis AFB
ATTACHMENT J
INDIVIDUAL SPACE CRITERIA DATA SHEETS ATTACHMENT J
INDIVIDUAL SPACE CRITERIA DATA SHEET
Space: Main Entry
Size (s.m.): 79 SF Occupancy: Assembly: 15/p = 5 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: Densified, polished concrete
Walls: Painted Gypsum board, rubber base
Ceiling: Acoustic ceiling
Clear Ceiling Height:
Windows: Hollow and clerestory
Doors: Aluminum full lite
Adjacencies: Dining, Serving line
Features:
Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade
Walls: Nonbearing metal stud walls
Ceiling: 2x4 suspended metal grid
HVAC:
Heating: � Air Conditioning � Ventilation �
Temperature:
Special Requirements:
PLUMBING:
Fixtures:
Shop Air: � Equipment Air: � Floor Drains: �
Natural Gas: � Other:
FIRE PROTECTION:
System Type: Automatic Fire protection – sprinkler system
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: �
Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Other:
GFGI:
Space: Entry Hall
Size (s.m.): 850 SF Occupancy: Assembly: 15/p= 57 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum Board, rubber base Ceiling: acoustic ceiling Clear Ceiling Height: 15’-0” Windows: N/A Doors: Hollow Metal Adjacencies:
Features:
Furnishings: Coat and Hat Racks
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud wall Ceiling: 2x4 Suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per Base Design Guidelines Special Requirements:
PLUMBING:
Fixtures: Hi-low Water cooler
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Per Base Design Guidelines
Special Requirements:
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
OTHER COMMENTS:
Provide convenience power and power for high-low water cooler
Space: Dining Room
Size (s.m.): 3218/4695/6092 SF Occupancy: Assembly: 15/p =215/313/406 Function: Dining Room
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Acoustic 2x4 “Second Look” Clear Ceiling Height: +15’-0” Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Serving Line, Entry Features:
Furnishings:
STRUCTURAL:
Floor: concrete slab on engineered grade Walls: metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed 2x4 prismatic
Special Requirements: Provide power and data to accommodate GFGI TVs and convenience power Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
GFGI: 32 Booths, 78 Tables, 312 Chairs and 3 Flat Screen TV’s hanging from ceiling
Size varies per Base bid/Option 1/Option 2
Space: Option 4 Dining
Size (s.m.): 2356 SF Occupancy: Assembly: 15/p = 157 Function: Semi-Private Dining area Note: Space already counted in “Dining Room”
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum board Ceiling: “Second Look” acoustic tile Clear Ceiling Height: 15’-0” AFF Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Dining Features: Full height walls with doors to main dining area, folding partition to further segregate room Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud; hot rolled steel tube exterior with metal siding Ceiling: 2x4 Suspended metal frames Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements:
Security:
Light Level: Per UFC requirements
EQUIPMENT:
Cranes/Hoists:
Other: Tables and chairs from “Dining room,” 3 ceiling mounted flat screen TVs
Provide convenience outlets and power at ceiling for TVs
Space: Serving
Size (s.m.): 1971 Occupancy: Assembly:15/p = 132 Function: Feeding queue
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies: Main Entry, Checkouts Features:
Furnishings:
STRUCTURAL:
Floor: concrete slab on engineered grade Walls: Nonbearing metal stud walls;
Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures:
Natural Gas: � Other: Floor sinks as required for equipment
Hazard Class:
Detection:
ELECTRICAL:
Telephone: X� LAN: X� PA: � Lighting Recessed prismatic
Power Provide convenience outlets and floor outlets for equipment
Space: Kitchen Prep
Size (s.m.): 1925 Occupancy: Factory: 200/p= 10 Function: Food Preparation Kitchen
ARCHITECTURAL:
Finishes:
Floor: High friction ceramic tile Walls: Painted Gypsum board, rubber base Ceiling: food service grade acoustic Clear Ceiling Height:
Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Serving Line, Food Storage Features: FRP or other moisture and impact guard on Walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: _x__- Sinks, ___-Floor Sinks, ___-floor drains
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements:
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Other: See drawing and specifications for Food Service equipment
Provide convenience outlets and power for equipment
Space: Kitchen Hall
Size (s.m.): 395 SF Occupancy: Factory: 200/p = 2 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: High friction ceramic tile Walls: Painted Gypsum board, tile base Ceiling: Food Service grade acoustic ceiling Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies:
Features: FRP or other impact resistant guard on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: As required per UFC Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets Security: As required per FUC Light Level:
EQUIPMENT:
Cranes/Hoists:
Space: Dining Janitor Closet
Size (s.m.): 49 SF Occupancy: Utility: 300/p =1 Function: Janitor Closet
Floor: Sealed concrete
Walls: Painted Gypsum Board
Ceiling: Acoustic moisture resistant
Clear Ceiling Height:
Windows: N/A
Doors: Hollow Metal
Adjacencies: Dining, restrooms
Features: Wainscoting – FRP all walls
Walls: Nonbearing metal stud walls
Fixtures: Mop Sink
Lighting:
Special Requirements: Provide ceiling or wall mounted power at 48” AFF
Space: Restrooms
Size (s.m.): 420 SF Occupancy: Utility: 300/p = 2 Function: M/F Public Restrooms
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, sealed, polished concrete Walls: Painted Gypsum board Ceiling: Acoustic moisture resistant Clear Ceiling Height:
Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Dining Area Features: Wainscoting- FRP or other moisture and impact resistant guard on all walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade with applied hardener Walls: Nonbearingmetal stud wall Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per Base Design Guidelines Special Requirements:
PLUMBING:
Fixtures: 2 Lavatories, (2M,3W) water closets, (3M,4W), urinals (2M)
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed fixtures prismatic
Special Requirements: Provide convenience outlets Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Other: Soap dispensers, paper towel dispensers, and garbage can per base design guidelines
Space: Staff Hall
Size (s.m.): 137 SF Occupancy: Business: 100/p =1 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: High-friction ceramic tile Walls: Painted Gypsum board, rubber base Ceiling: food service grade acoustic ceiling Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies:
Features: FRP or other impact resistant guard on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: As required for UFC Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Provide full height metal lockers on wall opposite Office/Training
Space: Service Hall
Size (s.m.): 261 SF Occupancy: Factory: 100/p = 2 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: High friction ceramic tile in kitchen area/densified, polished concrete in public area Walls: Painted Gypsum board, tile base Ceiling: Food Service grade acoustic ceiling Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies:
Features: FRP or other impact resistant guard on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Space: Food Storage
Size (s.m.): 1307 SF Occupancy: Storage: 300/p=4 Function: Food Storage room
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum Board, rubber base Ceiling: Food Grade acoustic Clear Ceiling Height: +12’-0” AFF Windows: Hollow metal clerestory Doors: Hollow Metal or FRP Adjacencies: Receiving, Food Prep Kitchen Features: FRP or other moisture and impact guard on walls, built- walk in freezers, refrigerators Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures:
Hazard Class:
Detection:
ELECTRICAL:
Telephone: X� LAN: X� PA: � Lighting:
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Other: Desk, w/drawers overhead storage, computer, printer, floor scale, 60 mobile shelves 10 dry storage #10 can racks, 2 self contained refrigerator unit, phone, jack pallet
Provide convenience outlets and power for equipment
Space: Dishwashing Room
Size (s.m.): 759 SF Occupancy: Factory: 200/p= 4 Function: Dish and Pot washing
ARCHITECTURAL:
Finishes:
Floor: high friction ceramic tile Walls: Painted Gypsum Board at 8’, FRP to 8’ AFF Ceiling: Food service grade acoustic Clear Ceiling Height: 12’ Windows: Hollow metal clerestory Doors: Hollow Metal Adjacencies: Dining Room, serving line Features: FRP or other moisture resistant guard on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding Ceiling: 2x4 Suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures:
Natural Gas: � Other: Water supply and sanitary sewer as required for equipment
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements: As required for equipment Security:
Light Level: Per UFC requirements
EQUIPMENT:
Other:: Clipper/dishwaser w/counter and sink with sprayer, 4 metal shelves, 45 clipper racks, : 4 busing cart, 7 floor pan shelves, See drawing for complete equipment schedule
Space: General Storage
Size (s.m.): 43 SF Occupancy: Storage: 300/p= 1 Function: Stock Room
Floor: Densified, stained, polished concrete
Walls: Painted Gypsum board, rubber base
Ceiling: Food service grade acoustic
Clear Ceiling Height:
Windows: N/A
Doors: Hollow Metal
Adjacencies: Electrical Room
Features: 5/8” Fire-resistant Plywood on Walls
Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding
Fixtures: N/A
Telephone: X� LAN: X� PA: �
Lighting:
Special Requirements:
Provide convenience outlets
Space: Refuse and Recycling
Size (s.m.): 185 SF Occupancy: Storage: 300/p= 1 Function: Storage Room
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food Service grade acoustic Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies: Kitchen, Loading Dock Furnishings: FRP or other impact resistant surface on walls
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud; hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements:
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Space: Training Room
Size (s.m.): 275 SF Occupancy: Assembly: 15/p= 18 Function: Training- Conference- Break Room
Floor: Densified, stained, polished concrete
Walls: Painted gypsum board, rubber base
Ceiling: Acoustic – food service grade
Clear Ceiling Height: +10’-0” AFF
Windows: Hollow Metal
Doors: Hollow Metal
Adjacencies: Office, Kitchen
Floor: concrete slab on engineered grade
Walls: Nonbearing metal stud walls (Int.), PEMB w/metal stud framing on interior face
Temperature: Per Base Design Guidelines
Lighting: Recessed 2x4 direct/indirect
Special Requirements: Provide power and data to accommodate equipment listed below
Light Level: Per Base Design Guidelines
Cranes/Hoists: N/A
Other: conference room table w/chairs, 2 computers, 1 printer, 1 copier, 3 book shelves, GFGI: 1 phone, 2 small computer desks w/chairs, projector w/projection screen
Space: Office
Size (s.m.): 206 SF Occupancy: Utility:100/p = 2 Function: Office
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, and polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food service grade acoustic Clear Ceiling Height:
Windows: Hollow Metal Doors: Hollow Metal Adjacencies: Food Prep, Training Features:
Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls (interior); hot rolled steel tube exterior with metal siding Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed direct/indirect
Special Requirements: Provide power for equipment noted below Security:
Light Level: Per Base Design Guidelines
EQUIPMENT:
Cranes/Hoists:
Other: 2 desks, safe, 2 computers, 1 printer, 2 book shelves, 2 filing cabinets, 2 phones, 1 fax
Space: Closet
Size (s.m.): 52 Occupancy: Storage: 300/p=1 Function: Stock Room / area
Floor: Densified, stained, polished concrete
Walls: Painted Gypsum board, rubber base
Ceiling: Food service grade acoustic
Clear Ceiling Height:
Windows: N/A
Doors: Hollow Metal
Adjacencies: Kitchen Toilets
Features: 5/8” Fire Resistant Plywood on Walls
Walls: Nonbering metal stud walls; hot rolled steel tube exterior with metal siding
Temperature: As required per code
Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets
Space: Exit Hall
Size (s.m.): 122 SF Occupancy: Business: 100/p=1 Function: Circulation
ARCHITECTURAL:
Finishes:
Floor: High-friction ceramic tile Walls: Painted Gypsum board Ceiling: food service grade acoustic ceiling Clear Ceiling Height: 12’-0” AFF Windows: N/A Doors: Hollow Metal Adjacencies: Offices Features: FRP or other impact resistant guard on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls Ceiling: 2x4 Suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: Hi-low Water cooler
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets and power for water cooler Security:
Light Level: As required per code
EQUIPMENT:
Cranes/Hoists:
Space: Receiving
Size (s.m.): 70 SF Occupancy: Business: 100/p = 1 Function: Stock receiving
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished concrete Walls: Painted Gypsum board, rubber base Ceiling: Food Service grade acoustic Clear Ceiling Height: 12’-0” Windows: Hollow metal view window to dock Doors: Hollow Metal Adjacencies: Dock, Food Storage Features: Wall guards Furnishings:
STRUCTURAL:
Floor: concrete slab on engineered grade Walls: metal stud frames; hot rolled steel tube exterior with metal siding Ceiling: 2x4 grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Recessed prismatic
Special Requirements: Provide convenience outlets and power for equipment per Base Design Guidelines Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
GFGI: Coat rack, small desk, 3 dollies
Space: Mechanical
Size (s.m.): 861 SF Occupancy: Utility:300/p = 3 Function: Mechanical Equipment
ARCHITECTURAL:
Finishes:
Floor: Sealed Concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies: Electrical Room Features: 5/8” Fire-resistant Plywood on Walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Load bearing metal stud walls; hot rolled steel tube exterior with metal siding Ceiling: N/A Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: As required per UFC Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Suspended from structure
Special Requirements: Provide power as required for equipment and service Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Provide access ladder and roof/hatch to mechanical well at roof
Space: Communications Room
Size (s.m.): 68 SF Occupancy: Utility: 300/p =1 Function: Telephone and Data
ARCHITECTURAL:
Finishes:
Floor: Densified, stained, polished Concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies: Electrical Room Features: Fire rated ¾” Plywood on walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: Nonbearing metal stud walls; hot rolled steel tube exterior with metal siding Ceiling: N/A Open to deck Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature: Per UFC requirements Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements:
Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Space: Kitchen Janitor Closet
Size (s.m.): 69 SF Occupancy: Utility: 300/p= 1 Function: Janitor Closet
ARCHITECTURAL:
Finishes:
Floor: Sealed concrete Walls: Painted Gypsum board Ceiling: Acoustic moisture resistant Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies: Offices Features: Wainscoting – FRP all walls Furnishings:
STRUCTURAL:
Floor: concrete slab on engineered grade Walls: nonbearing metal stud walls Ceiling: 2x4 suspended metal grid Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: Mop Sink
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting: Ceiling or wall mounted
Special Requirements: Provide power at 48” AFF Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Space: Toilets
Size (s.m.): 136 (combined) SF Occupancy: Utility:300/p :1Function: M/F Staff Restrooms
Floor: Densified, stained, polished concrete
Walls: Painted Gypsum Board
Ceiling: Acoustic moisture resistant
Clear Ceiling Height: +10’-0”
Windows: N/A
Doors: Hollow Metal
Adjacencies: Offices, Kitchen
Features: FRP Wainscoting at all walls
Floor: concrete slab on engineered grade
Walls: Nonbearing metal stud walls (int.)
Temperature: Per Base Design Standards
Fixtures: Ultra High-Efficiency Lavatory, water closet (toilet)
Lighting: Recessed 2x4 prismatic
Special Requirements:
Light Level: Per Base Design Guidelines
Other: Paper towel dispenser, soap dispenser, trash receptacle, etc. per Base Design Guidelines
Space: Electrical Room
Size (s.m.): 166 SF Occupancy: Utility:300/p= 1 Function: Electrical Equipment Room
ARCHITECTURAL:
Finishes:
Floor: Sealed concrete Walls: Painted Gypsum board, rubber base Ceiling: N/A Clear Ceiling Height:
Windows: N/A Doors: Hollow Metal Adjacencies: Comm. Room Features: ¾” Fire-Resistant Plywood on Walls Furnishings:
STRUCTURAL:
Floor: Concrete slab on engineered grade Walls: PEMB frame, nonbearing/metal stud walls (interior) Ceiling: N/A Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures:
System Type:
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements: Provide power and data as required for electrical equipment Security:
Light Level: As required by UFCs
EQUIPMENT:
Cranes/Hoists:
Space: Loading Dock
Size (s.m.): 466 SF (233 effective size) Occupancy: Exterior Utility:300/p = 1Function: Loading area
ARCHITECTURAL:
Finishes:
Floor: Sealed concrete Walls: hot rolled steel tube exterior with metal siding Ceiling: hot rolled steel tube exterior with metal siding Clear Ceiling Height:
Windows: Hollow metal view window Doors: Hollow Metal Adjacencies: Mechanical, Receiving, Food Storage Features: Capability for 48” high truck bed loading/unloading Furnishings:
STRUCTURAL:
Floor: concrete slab on engineered grade Walls: Metal framing; hot rolled steel tube exterior with metal siding Ceiling:
Features:
HVAC:
Heating: � Air Conditioning � Ventilation � Temperature:
Special Requirements:
PLUMBING:
Fixtures: N/A
Hazard Class:
Detection:
ELECTRICAL:
Telephone: � LAN: � PA: � Lighting:
Special Requirements: Intercom Security:
Light Level:
EQUIPMENT:
Cranes/Hoists:
Hydraulic dock leveler may be used in lieu of, or in combination with, recessed dock to provide 48” dock height capability.
ATTACHMENT K
GEOTECHNICAL REPORT ATTACHMENT K
| Attachment I |
| Attachment J |
| Attachment K |
File details come from the government source that posted it. Updated .