About this file
These Technical Exhibits detail specifications for Anti-Terrorism Force Protection (ATFP) unit price book line items for installation access control points, covering multiple security infrastructure components. The documents provide detailed technical requirements for various security systems and elements, including cable trench details, ballistic and blast-rated windows, guard shelters, exterior lighting, electronic security systems, vehicle barrier systems, and fencing.
Specific technical exhibits cover detailed specifications for components such as HD cameras with pan/tilt/zoom capabilities, digital video analytical monitoring systems, under vehicle scanning systems, active barriers and bollards, and different fence types (ornamental steel, wooden security). Each exhibit includes precise measurements, material specifications, installation requirements, and performance standards for security infrastructure elements, designed to support comprehensive anti-terrorism protection measures for military installation access control points.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| E.01.02 ATTACH 2 UPB_Europe_2025_Excel version.xlsx | XLSX spreadsheet | |
| E.01.02 ATTACH 2.1 JOCPB Guidebookv5.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL EXHIBITS
for
ANTI‐TERRORISM FORCE
PROTECTION UNIT PRICE BOOK LINE
ITEMS
TECHNICAL EXHIBITS
EXTERIOR SITE WORK
TE – 0201A CABLE TRENCH DETAILS
BUILDINGS AND STRUCTURES
TE – 0401A BALLISTIC RATED WINDOWS
TE – 0402X BLAST RATED WINDOWS AND DOORS
TE – 0403A GUARD SHELTER STANDARD CONSTRUCTION
TE – 0403N GUARD SHELTER TYPE IV
ELECTRICAL SYSTEMS
TE – 0503A EXTERIOR LIGHTING AND ELECTRONIC SECURITY DETAILS
ELECTRONIC SECURITY SYSTEMS
TE – 0601A BUILDING ACCESS CONTROL AND MONITORING
TE – 0604A CLOSED CIRCUIT TV SYSTEM
TE – 0605A DIGITAL VIDEO ANALYTICAL MONITORING SYSTEM
TE – 0606A UNDER VEHICLE SCANNING SYSTEM
VEHICLE BARRIER SYSTEMS
TE – 0702A ACTIVE BARRIERS AND BOLLARDS
TE – 0702KK ACTIVE BOLLARDS
TE – 0703R ACP CORRIDOR WALLS AND NATURAL BARRIER
FENCING AND GATES
TE – 0802K VIEW BLOCKING SLATS FOR FENCE
TE – 0802Q ORNAMENTAL FENCE SYSTEM TYPE 1
TE – 0802R STEEL ORNAMENTAL FENCING PANELS
TE – 0802Y WOODEN SECURITY FENCE
TE – 0805E PAVEMENTS 18” CURB
kmarshall Text Box
TE - 0201A
kmarshall
TECHNICAL EXHIBIT
TE - 0201A
kmarshall
TE - 0201A
kmarshall
TE - 0201A
kmarshall
TE - 0201A
kmarshall
Minimum Specifications: Type I - Safety Film
Total Solar Transmission: 78.08% Absorption: 18.0% Reflection: 4.0% Emissivity: 0.88 UV Transmission (measured at 300-380 mm): 1.0% U-factor: 1.08 Shading Coefficient: 0.89 Visible Light Transmission: 85.0% Overall Reduced Rays on Glass: 23.0% Thickness: 112 µ (1.5 mil = 37 µ)=4.5 mil Adhesive strength: 3200 grams/in (8128.02 grams/cm) Tearing Strength: 95 ply or 17kg/cm
Minimum Specifications: Type II - Silver Safety Film
Total Solar Transmission: 11.6% Absorption: 36.8% Reflection: 51.6% Emissivity: 0.81 UV Transmission (measured at 300-380 mm): 0.8% U-factor: 1.11 Shading Coefficient: 0.29 Visible Light Transmission: 18.0% Overall Reduced Rays on Glass: 75.0% Thickness: 112 µ (1.5 mil = 37 µ)=4.5 mil Adhesive strength: 3200 grams/in (8128.02 grams/cm) Tearing Strength: 95 ply or 17kg/cm Expansion when breaking: 160%
Minimum Specifications: Type III – Laminated Safety Film
UV Transmission (measured at 300-380 mm): Approximate 0.2% U-factor: 1.08 Shading Coefficient: 0.89 Visible Light Transmission: 85.0% Overall Reduced Rays on Glass: Approximate 81.0% Thickness: 225 mue (1.5 mil = 37 mue)= 9 mil Adhesive strength: 3200 grams/in (8128.02 grams/cm) Tearing Strength (Linear Measuring): 44 kg/cm Expansion when breaking: 170.0%
BALLISTIC RATED WINDOWS
Public Works Section Europe District
APO AE 09096
INDEFINITE DELIVERY INDEFINITE QUANTITY
GLAZING
AND
WINDOWS
TE-
0401A
Minimum Specifications: IIIA, fragmentation retention film, with sun protection coating
Furnish and install minimum 9-mil thick window safety film.
Shading Coefficient: Maximum 0.50 Visible Light Transmission: 20.0% Adhesive strength: 2650 grams/in (6732grams/cm) Tearing Strength (Linear Measuring): 44 kg/cm
Minimum Specifications: Type IV, fragmentation retention film, clear
Furnish and install 15-mil thick window safety film. Materials and installation must be certified in accordance with UL 972.
Shading Coefficient: Maximum 0.90 Visible Light Transmission: 85.0% Adhesive strength: 2650 grams/in (6732grams/cm) Tearing Strength (Linear Measuring): 60 kg/cm Expansion when breaking: 170.0%
Minimum Specifications: Type IVA, fragmentation retention film, with sun protection coating
Furnish and install 15-mil thick window safety film. Materials and installation must be certified in accordance with UL 972.
Shading Coefficient: Maximum 0.50 Visible Light Transmission: 20.0% Adhesive strength: 2650 grams/in (6732grams/cm) Tearing Strength (Linear Measuring): 60 kg/cm
WINDOWS
BLAST CURTAINS
Drapery shall be tested and certified to a minimum overpressure of 27.58 kPa with an impulse of 199.95 kPa-msec. Provide test reports indicating that the manufacturer’s blast curtain has been tested in a live explosion environment and demonstrates the ability to mitigate glass and collateral ballistics associated with the explosion. Testing shall be performed by an entity with experience in said testing.
EMI/RFI MESH
Wire Mesh capable of providing a high level of radio frequency attenuation in the range of 1MHz to 10 GHz. Provide testing results.
BULLET RESISTANT WINDOWS
Characteristics of BULLET RESISTANT WINDOWS:
Furnish and install bullet resistant windows and frame assembly in existing window openings in accordance with DIN EN 1522 and EN 1063 standards.
Frames shall be non-operable (not turn / tilt type) and operable (turn / tilt type) factory painted or anodized steel or aluminum.
Work shall include removal and disposal of existing windows, repair, patching and painting of rough window opening and complete installation of new window unit or glass.
Categories are defined as follows:
CAT 4: FB 5 / BR 5 or UL Level 4 CAT 5: FB 6 / BR 6 or UL Level 5
WINDOWS
Minimum 6 mm laminated glass consisting of two nominal 3 mm glass panes bonded together with a minimum of a 0.75 mm interlayer of a material designed for blast resistance. UL 752 Level 3 acceptable.
Pressure and Impulse Values with Standoff Distance (EWI)
Range(m) Pressure (kPa) Impulse (kPa-msec)
10 845.50 1,542.63 15 272.20 954.99 20 137.34 688.10 25 87.08 536.83 30 62.60 439.75 35 48.47 372.25 40 39.30 322.61 45 33.03 284.55 50 28.34 254.55 55 24.82 230.15 60 21.99 210.08
Pressure and Impulse Values with Standoff Distance (EWII)
Range(m) Pressure (kPa) Impulse (kPa-msec) 10 235.87 563.58 15 95.70 356.87 20 56.81 260.48 25 39.78 204.91 30 30.41 168.85 35 24.48 143.48 40 20.41 124.66 45 17.44 110.25 50 15.17 98.73 55 13.44 89.36 60 12.00 81.63
BLAST RATED WINDOWS
INSTALLATION ACCESS CONTROL POINTS
0402X
The occupancy of the gatehouse, guard booths, and overwatch facilities are typically below the threshold for the requirements of UFC 4-010-01 DOD Minimum Antiterrorism Standards for Buildings. Therefore, typically no protective design elements are required for the gatehouse, guard booths and overwatch facilities to mitigate the effects of an explosive device.
Permanent sentry or guard booths at installation access control points or entry control facilities shall be shielded or hardened to protect against ballistic threats. This shall be incorporated into all new guard facilities and major renovations of existing structures. For facilities with sentry/guard booths combined with pass and ID centers, only the portions of the structure designated for guard personnel require this level of protection. All existing structures shall meet this standard. At a minimum, ballistic protection equivalent to U.S. UL 752 Level V or European CEN B6/BR6 (7.62 ballistic protection) shall be the standard for all frontal components, while Level III is the standard for the non-threatened sides. Glazing will be no-spall (NS) rated.
(Pictured 1.50m x 2.40m; 2.40m x 6.00m)
GUARD SHELTER STANDARD CONSTRUCTION
MODULAR
BUILDINGS
0403A
Guard Shelter, Level IV (Dimensions: 2.40m x 6.00m)
Specifications:
Ballistic Resistance: Type Level IV or UL 9 A/C: 12,000 btu heat/cool Gun Ports: 6 Pieces, 15.00cm x 10.00cm
Features:
Windows with “No Spall” Protection Physical Ventilation with Anti-Blast Protection Desktop: 2 pieces Chairs: 6 pieces Communication Interphone: 2 pieces First Aid Kit: 2 Pieces Fire Extinguisher: 2 Pieces
GUARD SHELTER TYPE IV
PRE-
ENGINEERED
BUILDINGS
0403N
Refer to UFC 3-530-01, section 6-2 for controlled lighting.
Refer to UFC 3-530-01, section 6-1 for minimum lighting criteria.
Flood Light Fixture, Typical
Building Mounted LED Light Fixture, Typical
Building Mounted LED Lighting Fixture, Typical
EXTERIOR LIGHTING AND ELECTRONIC SECURITY DETAILS
EXTERIOR
LIGHTING
0503A
LED Fixture with Pole Adapter
Ceiling Mounted High Bay LED Light Fixture
EXTERIOR LIGHTING AND ELECTRONIC SECURITY DETAILS
EXTERIOR
LIGHTING
0503A
A. Roller Door Contact Switch: Shutter door contact including magnet, installation material and cable; Surface mount, Max. 40V_, 1 pin open contact, 6 VA Maximum loop rating, Polyamide GF housing - AMK4Z
B. PIR 360° Ceiling Panoramic Detector: 360 degrees x 14 meter coverage, low profile design, 50 detection zones, 1, 2, 3 or 4 pulses Count selectability -DS937
C. PIR/Microwave 360° Ceiling Panoramic Detector: 360 degrees X 18 meter pattern, 2.5 to 6 meter mounting height, ceiling mounted, Supervised microwave + PIR sections self-test, ENSO131-1, grade 2 compliant, -DS9360
D. FKS Foot Contact Switch: Manual triggering of alarms with a foot.
E. PIR/Microwave 90° Tri-focus Detectors: anti-mask, 18 meter X 25 meter broad coverage, Tri-Focus optics, High-impact ABS plastic, 5V digital alarm, Normally closed solid state and supervised contact, tamper circuit. ENSO131-2-4 grade 3 compliant - ISC-PDL1-WA18x
F. PIR 90° Dectector: 11 meter X 11 meter broad coverage, Dual sensor, Quad Element, eight detection layers, High-impact ABS plastic, 5V digital alarm, Normally closed solid state and supervised contact, tamper circuit, ENSO131-2-2, grade 2 compliant - ISM- BLQ1
G. Magnetic Contact Switch: contains on contact and one magnet to mount on doors or windows, Single pole single throw switch ISN-CSM20-WG
A-G. Alarm Line Modules, DTLM1 DTLM2 DTLM3 MELM1 MELM2 MELM3 SBMS3-2707A- Input 1: NO or NC(Alarm), Input 2: NO (RQE), Input 3 NC (Tamper), Total Impedance: 10 Ohm
H. DIGI*TRAC Annunciator: Intelligent Display for Alarm History, Input Status, and Relay
Status of points in connected controller. Includes MRIB. Requires CCM 7.0.22 or later. Used in conjunction with DS47L ScramblePad (or card reader using MATCH Version 38 or higher) for activation. For Lock and Leave applications
I. DIGI*TRAC Model 2 Controller: Controls 2 Fully supervised Doors and 2 Unsupervised
Doors with Keypads or Readers, Standalone or Networked, Digital Transmission, Encryption Algorithm, Local or Remote Programming, Printer Port, Multiple Reader Technology. Subject to Contracting Officers Approval.
BUILDING ACCESS CONTROL AND MONITORING
ELECTRONIC
SECURITY
SYSTEMS
0601A
J. DIGI*TRAC Model 8 Controller: Controls 8 Fully supervised Doors with Keypads or Readers, Standalone or Networked, Digital Transmission, Encryption Algorithm, Local or Remote Programming, Printer Port, Multiple Reader Technology. Subject to Contracting Officers Approval.
K. DIGI*TRAC Model 16 Controller: Controls 16 Fully supervised Alarm Inputs, Standalone or
Networked, Digital Transmission, Encryption Algorithm, Local or Remote Programming, Printer Port, Multiple Reader Technology. Subject to Contracting Officers Approval.
L. SCM Smart Card Reader, CR-SCM-CCLK (PAT1241): Contact reader and 13.56MHz
Contactless reader. Reads PIN accessed CAC 1 EDIPI (Field 5) for Contact interface providing 36 bit Wiegand output. Reads MIFARE/DESFire serial numbers (50 bit Wiegand output), and PIV II (75 bit GSA Wiegand output) for Contact interface. 40mm read range.
M. Match Reader Interface Board, MRIB: Accepts up to 2 readers & 2 ScramblePads for dual technology entry & exit control of 1 door. Use with CCM 6.4 (or higher) & CR readers
N. DS47L –SSP-HE-HL Scramble Pad: ScramblePad with embedded 125kHz proximity and 13.56MHz, ISO 14443 A&B contactless smart card readers and antennae. Reads FPS201 PIV II End Point, DESFire (with CHUID only), iCLASS, and HID 125kHz proximity. Pin code of 3 to 16 digits. Supports MATCH code technology. High Intensity LED display, Compatible with DOD CAC Cards.
O. ScramblePad, DS47L: Patented scrambling display & viewing restriction. Includes audible annunciator, 4 status LEDs & physical tamper switch. Moisture, dust, dirt and ESD resistant.
Includes Standard (non-custom) MATCH function for 1 or 2 readers.
P-R. Card Reader Mounting Box: With tamper switch
S. Alarm Expansion Board, AEB8: Adds 8 additional high security alarm inputs. Each input requires appropriate line module, removable connectors.
T. Velocity Management Software: Velocity Server and Client application software. CD installs Single User, Server, or Client. Server supports up to 999 clients, also included. For networks of DIGI*TRAC controllers (CCM-F Version 7.4 or higher).
U. SHDSL EFM Line Card: Provides high-density, EFM-compliant SHDSL aggregation, delivers high-speed Ethernet services, provides 24 individual single copper pair lines for data ranges from 144Kbps to 5.7Mbps.
SYSTEMS
V. Duress Alarm Panic Button: Single push button to activate the alarm, does not require a reset, mountable in inconspicuous location. Subject to Contracting Officers Approval.-
UM1D
W. High Security Surface Mount Magnetic Contacts: -triple biased, surface mounted contact and actuating magnet housings, supervised loop with series magnetic tamper and pry tamper, anodized aluminum, gap distance=.2” to .6”, Listed UL 634 level 1 High Security Switch.
Y-Z. Access Cards: With high frequency chip and with low frequency chip.
AA. Secure Network Interface Board 3, SN1B3: IDENTIV SNIB3 or equal.
BB. Enrollment Station: IDENTIV SMES-PC-RP40-USB or equal.
CC. Exterior Infrared Sensors: OPTEX LX-402 or equal.
DD. Exterior Microwave Sensors: ZENCONTROL ZC-MW-WALL-WP or equal.
EE. ABUS Power Supply: Russound AH484 or equal.
FF. Plastic Wall Channel: N/A.
GG. J-(ST)Y 6x2x.06 Wiring Cable: N/A.
HH. AECS Badging Printer: Double sided color printer using color dye sublimation, monochrome thermal printing and rewritable technology.
SYSTEMS
HD Camera, Pan/Tilt/Zoom and Fixed, IP Compatible
Power: +12 VDC ±5%, 24 VAC ±10% or Power-Over-Ethernet (48 VDC nominal) input voltage. 5.55 W max.
power consumption (DC). 5 W max. power consumption (AC). 6 W max. power consumption (PoE).
Video Streaming: H.265; H.264; M-JPEG video compression. Multiple configurable streams in H.264 or H.265 and M-JPEG, configurable frame rate and bandwidth. <120 ms (max average at 1080o30) camera processing latency. IP, IBP, IBBP GOP structure. 1 to 25 [30] fps encoding interval. Encoding regions up to 8 areas with encoder quality settings per area.
Video Resolution: 1080p HD: 1920 x 1080. Upright mode 1080p: 1080 x 1920. 1.3 MP (5:4)(cropped): 1280 x 1024. Upright mode 1.3 MP (5:4) (cropped): 1024 x 1280. 720p: 1280 x 720. Upright mode 720p: 720 x 1280.
480p SD: 640 x 480. 240p SD: 320 x 240.
Video Functions: Color, monochrome, auto (adjustable switch points). Contrast, saturation, brightness adjustable picture settings. 2500 to 10000K, 4 automatic mode white balance. Automatic electronic shutter.
On/off/auto backlight compensation. On/off contrast enhancement. SNR >55 dB. Noise reduction with separate temporal and spatial adjustments. Selectable sharpness enhancement. Automatic fog adjustment.
Programmable privacy masking. Automatic detection with manual override for camera rotation.
Video Content Analysis: Rule based alarms, line crossing, enter/leave, follow route, loitering, idle/removed object, people counting, crowd density estimating and 3D tracking. Audio detection.
Night Vision: Distance up to 30 m. LED high efficiency array. Adjustable IR intensity.
Optical: 3 to 10 mm automatic varifocal lens, IR corrected. Board mounted. Motorized zoom/focus adjustment. Automatic iris control. Horizontal field of view 34° to 101°. Vertical field of view 19° to 54°.
Input/Output: SMB connector analog video out. Audio line in 0.707 Vrms max, 10 kOhm typical, jack connector. Audio line out 0.707 Vrms max, 10 kOhm typical, jack connector. Built in microphone. 1 alarm input and 1 alarm output.
Local Storage: 60 s pre-alarm recording internal RAM. Memory card slot. Continuous recording, ring recording, alarm/events/schedule recording.
Network: IPv4, IPv6, UDP, TCP, HTTP, HTTPS, RTP/RTCP, IGMP V2/V3, ICMP, ICMPv6, RTSP, FTP, ARP, DHCP, APIPA (Auto-IP, link local address), NTP (SNTP), SNMP (V1, V3, MIB-II), 802.1x, DNS, DNSv6, DDNS (DynDNS.org, selfHOST.de, no-ip.com), SMTP, iSCSI, UPnP (SSDP), DiffServ (QoS), LLDP, SOAP, Dropbox™, CHAP, digest authentication. TLS1.0/1.2, AES128, AES256 encryption.
Environmental: -20°C to +50°C (-4°F to +122°F) continuous operating temperature. 5% to 93% relative humidity (non condensing).
CLOSED CIRCUIT TV SYSTEM
0604A
Typical HD Camera with Pant/Tilt/Zoom; Typical HD Camera Fixed
Typical HD Camera Fixed with Infrared Lighting
CLOSED CIRCUIT TV SYSTEM
0604A
DIGITAL VIDEO ANALYTIC SYSTEM REQUIREMENTS:
Perimeter Violation: Real-time alarms established for virtual fences or “trespass lines” on gates or sectors where fencing is impractical, or to establish early warning boundaries outside of fences. Detects an intrusion at the perimeter of a defined virtual security zone.
Wrong Way Detection: Detects people moving against the flow of traffic.
People Counting: Measures people flow to determine high traffic and low traffic areas by facility, floor and/or building sector with real-time or periodic reporting for facility optimization.
PTZ GoTo: Allows control of pan/tilt/zoom (PTZ) cameras that automatically zoom and follow intruders and objects to detect, tag and track when a secure area is breached.
Loitering: Detects loitering behavior within a defined area.
Object Detection & Tracking: Detects, tags and tracks people and or objects within an area of interest per user-defined detection criteria.
Removed/Left Object: Identifies items such as packages, suitcases, and backpacks that have been left erroneously or purposefully. Can monitor important items that should not be removed from a defined area. Also known as Left and Removed Item Detection (LRID).
Moving Objects: Detects and classifies objects in a security zone by size, direction and speed.
Tailgating: Behavior recognition alarm for detecting unauthorized entry to a defined area through piggybacking of people or vehicles.
Traffic Congestion: Detects clusters of people, objects or vehicles moving together and then tracks, counts and monitors activity.
The Digital Video Analytical detection suite will analyze and proces incoming video and sensor feeds utilizing algorithms to detect specific activities and events for security and surveillance applications.
Digital Video Analytical software can be combined with additional intelligent browser-based mapping software to visualize the type and location of a suspected security breach. The system is designed to simultaneously detect multiple events and to process each event in accordance with user-defined parameter settings, and thus creates cognitive information and functions as a management platform in a network-centric environment; enabling decision makers to evaluate threats in real-time and collaborate using the same data. Digital Video Analytical system allows both real-time local and remote monitoring using a customized browser-based user interface combined with a standard Active-X plug-in. Digital Video Analytical comes with a user interface that enables users to set zones, create custom logic, and manipulate system parameters. Digital Video Analytical system features automatic failure recovery, strong encryption, custom policy management, diverse alarm notification methodology, multi-type sensor support, low bandwidth requirements for remote video and sensor access, and months of archive capability. All camera licenses shall include up to three behaviors.
DIGITAL VIDEO ANALYTICAL MONITORING SYSTEM
0605A
Typical Keyboard and 3D Mouse
Typical Pole Mount Typical Wall Mount
DIGITAL VIDEO ANALYTICAL MONITORING SYSTEM
0605A
Refer to UFC 4-022-01
Hardware: The Under Vehicle Surveillance System (UVSS) must provide a safe, thorough and efficient method for searching undercarriages of vehicles for hidden items such as explosive devices, weapons and any other type of contraband. System should be available as mobile and permanent system. A sensor, upon detection of an oncoming vehicle will activate the scanning unit before the vehicle is physically moving over the lens of the scanning unit. In the event that failure of LED’s does occur, the rest of the LED’s shall still be able to provide a high image resolution image. Lights must turn on and off automatically to conserve energy and prolong life span of the lighting module. The scanning unit must be equipped with a temperature sensor to activate flat panel heating when ambient temperature drops under 15°C/59°F. The complete digital line scan camera, connections, cables and any operating components of the camera must be designed for heavy-duty outdoor applications. Scanning unit and all metal parts must be of material that is non-corrosive, being weather/splash proof under light to medium wet weather conditions. Cables between scanner and computer must be a minimum of 30 m or 98’ long, with possibility to enlarge distance with additional workstation or booster box. Computer must be designed with industrial components. Scanning unit must have protective case and complete guide to facilitate the correct movement and positioning of the vehicle over it. Such positioning shall enable complete coverage and accessibility for scanning full vehicle undercarriage. Guides shall prevent scanning unit from any damage by oncoming vehicles, integrating with barriers, rising steps, bollards, etc.
Software: Operator display screen must be user friendly. Must require a secure password to access the system, logging officer’s time of usage, with possibility to create different user levels (usual user, administrator, etc.). UVSS must provide high image resolution and operate in all lighting conditions (day, night, etc.). Captured images must remain on-screen even after the vehicle passes for continued inspection. Images must be stored on a minimum 80 gigabyte solid state disc, with time and date stamps. Stored images must be automatically loaded to the monitor for visual comparative viewing purposes. Various gamma and tone control levels must be provided. Data shall be exportable to CD and/or USB. Must be able to trigger UVSS manually and input license plate numbers manually, with possibility to integrate a License Plate Recognition (LPR) system.
Performance Specifications:
Scan Type Digital Line Camera System Single, High Speed Minimum Camera Pixels 1024 Minimum Infrared LED Count 200 Maximum Vehicle Speed 40 km/h or 25 mph Imaging Speed 3-5 seconds (depends on length of vehicle) Image Zoom Instantaneous, up to 5mm or 0.2” Operating Temperatures -20°C to +45°C
UNDER VEHICLE SCANNING SYSTEM
INSTALLATION ACCESS CONTROL POINTS UVSS
0606A
MOBILE OR PERMANENT SYSTEM
PERMANENT SYSTEM
UNDER VEHICLE SCANNING SYSTEM
INSTALLATION ACCESS CONTROL POINTS UVSS
0606A
Active M50 Hydraulic Barrier Beam Widths: 4m, 6m, 8m Operates remotely by means of an integral Hydraulic Pumping Unit (HPU) that is wholly enclosed in the hinge end enclosure.
M50 Hydraulic Beam Beam Widths: 4m, 6m, 8m Height Above Ground: 915 mm - Beam Height When Deployed Foundation Depth: 305 mm - beam trench 1,220 mm - stanchion depth. Security Rating: ASTM: M50 P1 Finishes Available: Hot-dip galvanized and coated with a polyester coating in any RAL color specified.
M50 Hydraulic Wedge Width: 4m Height Above Ground: 965 mm Foundation Depth: 457 mm Finishes Available: Fully galvanized as standard, a black painted top lid with an anti-slip coating.
M50 Hydraulic Bollards Diameter: 273 mm Height Above Ground: 1000 mm Foundation Depth: 1684 mm Finishes Available: Galvanized as standard with two reflective yellow bands; painted or finished with a decorative sleeve.
Horizontal Crash Beam Width: Varies Power supply required is two 220/230/240 volt single phase 20 amp and two 110V 20 amp. Certified to stop 15,000 lb vehicle impact at 50 mph. ASTM F2656-07 M50 P2 certified.
M50 Barrier Lift System Width: 6m, 10m Blocking Height: 1100 mm Installation Depth: 510 - 1210 mm incl. 310 mm road covering Certification: DOD SD-STD-02.01 Rev.
ACTIVE BARRIERS AND BOLLARDS
Public Works Section Europe District
APO AE 09096
INDEFINITE DELIVERY INDEFINITE QUANTITY
INSTALLATION ACCESS CONTROL POINTS
VEHICLE
BARRIERS
0702A
ACTIVE BOLLARDS
VEHICLE
BARRIERS
0702KK
ACP Corridor Walls
Natural Barrier
1m x 1m x 1m minimum boulder with minimum weight of 2,250 kg embedded in the soil 20cm, on lean concrete bedding material.
ACP CORRIDOR WALLS AND NATURAL BARRIER
PASSIVE
BARRIERS
0703R
≥ 1m
VIEW BLOCKING SLATS FOR FENCE
INSTALLATION ACCESS CONTROL POINTS FENCING
0802K
TECHNCIAL EXHIBIT
ORNAMENTAL FENCE SYSTEM
TYPE 1
Public Works Section Europe District
APO AE 09096
INDEFINITE DELIVERY INDEFINITE QUANTITY
INSTALLATION ACCESS CONTROL
POINTS
METALS TE –05A
TE-
0802Q kmarshall
TE-
0802R kmarshall
TE-
0802R kmarshall
WOODEN SECURITY FENCE
INSTALLATION ACCESS CONTROL POINTS FENCING
0802Y
2.50 m
0.90 m
5 cm x 30 cm Cap
10 cm x 10 cm Nailer
15 cm x 15 cm Post at 2 m O.C
5 cm x 30 cm Vertical Plank, Anchored with Carriage Bolt without gaps
Concrete Footing
PAVEMENTS
18” CURB
Public Works Section Europe District
APO AE 09096
INDEFINITE DELIVERY INDEFINITE QUANTITY
ROADWORK TE – 02J
TE-
0805E kmarshall
PAVEMENTS
18” CURB
Public Works Section Europe District
APO AE 09096
INDEFINITE DELIVERY INDEFINITE QUANTITY
INSTALLATION ACCESS CONTROL POINTS
ROADWORK TE – 02J
kmarshall Text Box
TE-
0805E kmarshall
| 0201A.pdf |
| TOC Exhibits and Drawings 2015.pdf |
| TITLE |
| TE-02K Blast Curtains EMI-RFI Mesh 2015.pdf |
| BLAST CURTAINS AND EMI/RFI SHIELDING MESH |
| TE – 02K |
| SAFETY FILM |
| TE – 02K |
| SAFETY FILM |
| TE – 02K |
| SAFETY FILM |
| TE – 02K |
| BULLET RESISTANT WINDOWS |
TE – 02K
| TE-16A CCTV System 2015.pdf |
| CLOSED CIRCUIT TV SYSTEM |
| INSTALLATION ACCESS CONTROL POINTS |
| TE – 16A |
| CLOSED CIRCUIT TV SYSTEM |
| INSTALLATION ACCESS CONTROL POINTS |
| TE – 16A |
| CLOSED CIRCUIT TV SYSTEM |
| INSTALLATION ACCESS CONTROL POINTS |
TE – 16A
| TE-16D ACS-IDS v2 2015.pdf |
| BUILDING ACCESS CONTROL AND MONITORING |
| TE – 16D |
| BUILDING ACCESS CONTROL AND MONITORING |
TE – 16D