05_-_Attachment_II_-_Drawing_3_-_7T-1079-15_Power_Supply_to_Range_117.pdf
PDF 276 KB Posted
- Solicitation number
- W912PB-16-T-8027
About this file
Attachment II - Drawing 3
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE DESCRIPTION DRAWN BY APPROVED
PROJECT TITLE
USING UNITDATE
DATE
DATE
DATE
PROJECT ENGR CHECKED BY
DATE SCALE PROJECT NO
SHEET
OF
REV NO
NAME (PRINT) NAME (PRINT)
NAME (PRINT)NAME (PRINT)
SIGNATURE SIGNATURE
SIGNATURESIGNATURE
MASTER PLANNER
DRAWN BY
ENGR DIV
DESIGN / PROJ MGMT BR
USA GARRISON, BAVARIA
INSTALLATION
TOWER BARRACKS
P. SossallaP. Sossalla
Ludwig Gruenwald, C/Design & Proj Mgmt Br
26.04.2016
Ludwig Gruenwald 3
EMCS Scheme
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8
NSHV
RV GLT
Druck/Termp. Sch.
Druck/Termp. Sch.Druck/Termp. Sch.
NSP SchalterUeberspannungs-
Schutz
1. abisolieren, reinigen, einfuehren, beschriften aufloeten auf Loetstreifenverteiler Loet/Steck (250pol)
2. Anklemmen der DP in den einzelnen Verteilungen
Schaltfelder bzw. Feldgeraeten
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8
IY(St)Y 10x2x0.8
NSHV
RV GLT
Druck/Termp. Sch.
Druck/Termp. Sch.Druck/Termp. Sch.
NSP SchalterUeberspannungs-
Schutz
1. abisolieren, reinigen, einfuehren, beschriften aufloeten auf Loetstreifenverteiler Loet/Steck (250pol)
Schaltfelder bzw. Feldgeraeten
John Alan Howard C/Engr Div
A2YFL2Y 20 x 2 x 0.8 nach Geb. 3492
Transformatorschutz
Traforaum 1
NYM-I-10x1.5
Grafenwoehr Military Community - Tower Barracks
Transformer Station Range 117/21, USAG Bavaria, Extend Low Voltage Power Supply Line from Bldg.#3492 to
42A-01079-5P
Transformer Station 117-21
John Alan Howard Act.C/Master Planning
Trafo 1Station 401
Trafo 1 ausgeloest
Trafo 1 Warnung
Trafo 1
IY(St)Y 4x2x0.8
Trafo-Festkompensation
14x IY(St) 4 x 2 x 0.8
2x IY(St) 10 x 2 x 0.8
2x A2YFL2Y 10 x 2 x 0.8
4x NYM-I-10x1.5 qmm
2. Anklemmen der DP in den einzelnen Verteilungen
Station 117C2Down Range 117
DATE DESCRIPTION DRAWN BY APPROVED
PROJECT TITLE
USING UNITDATE
DATE
DATE
DATE
PROJECT ENGR CHECKED BY
DATE SCALE PROJECT NO
SHEET
OF
REV NO
NAME (PRINT) NAME (PRINT)
NAME (PRINT)NAME (PRINT)
SIGNATURE SIGNATURE
SIGNATURESIGNATURE
MASTER PLANNER
DRAWN BY
ENGR DIV
DESIGN / PROJ MGMT BR
USA GARRISON, BAVARIA
INSTALLATION
TOWER BARRACKS
P. SossallaP. Sossalla
Ludwig Gruenwald, C/Design & Proj Mgmt Br
26.04.2016
Ludwig Gruenwald 3
EMCS Scheme
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8
NSHV
RV GLT
Druck/Termp. Sch.
Druck/Termp. Sch.Druck/Termp. Sch.
NSP SchalterUeberspannungs-
Schutz
1. abisolieren, reinigen, einfuehren, beschriften aufloeten auf Loetstreifenverteiler Loet/Steck (250pol)
2. Anklemmen der DP in den einzelnen Verteilungen
Schaltfelder bzw. Feldgeraeten
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
Erdungsschalter
MSP - Schalter
IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8 IY(St)Y 4x2x0.8
IY(St)Y 10x2x0.8
NSHV
RV GLT
Druck/Termp. Sch.
Druck/Termp. Sch.Druck/Termp. Sch.
NSP SchalterUeberspannungs-
Schutz
1. abisolieren, reinigen, einfuehren, beschriften aufloeten auf Loetstreifenverteiler Loet/Steck (250pol)
Schaltfelder bzw. Feldgeraeten
John Alan Howard C/Engr Div
A2YFL2Y 20 x 2 x 0.8 nach Geb. 3492
Transformatorschutz
Traforaum 1
NYM-I-10x1.5
Grafenwoehr Military Community - Tower Barracks
Transformer Station Range 117/21, USAG Bavaria, Extend Low Voltage Power Supply Line from Bldg.#3492 to
42A-01079-5P
Transformer Station 117-21
John Alan Howard Act.C/Master Planning
Trafo 1Station 401
Trafo 1 ausgeloest
Trafo 1 Warnung
Trafo 1
IY(St)Y 4x2x0.8
Trafo-Festkompensation
14x IY(St) 4 x 2 x 0.8
2x IY(St) 10 x 2 x 0.8
2x A2YFL2Y 10 x 2 x 0.8
4x NYM-I-10x1.5 qmm
2. Anklemmen der DP in den einzelnen Verteilungen
Station 117C2Down Range 117