Amendment 0003 PlanSheet_S101.pdf
PDF 273 KB Posted
- Attached to
- 2019 Flood Repair of MSD Manholes:
- Solicitation number
- W912P921B0005
About this file
This document contains details for a federal solicitation seeking manhole rehabilitation services. The U.S. Army Corps of Engineers, St. Louis District is soliciting firms to rehabilitate manholes using the Cure-in-Place Manhole method. Firms will remove concrete and asphalt around manholes, replace pressure-rated frames and lids, clean and prep manholes, install a liner using heat and pressurization, and replace damaged risers. Restoration work includes repaving, landscaping, and restoring the areas around manholes. Solicitation W912P9-21-B-0005 will be an unrestricted Invitation for Bid issued on or around April 28, 2021 via the DOD SAFE website. The NAICS code is 237990 and size standard is $39.5 million. The project value is between $1-5 million. Interested parties must register at beta.SAM.gov and SAM.gov to receive notifications and be eligible for award.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DS: c:\users\b3ec9lms\pw_working\mvs\d0196767\AEC_Screen.dscript.dscriptPD: AEC_pdf.pltcfg
2020/11/17
2020/11/17
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A
N S I
D
T L
O U
IS
M
IS
S O
U R I
S
P R
U C
E S
T R
E E
T
S T L
O U
IS
D
IS
T R
IC
T
F
IL
E N
U M
B E
R
W P -X
X (Y
E A
R
X X
X X
X
W P -X
X (Y
E A
R
X X
X X
X
M
IS
S
IS
S
IP
P I
R
IV
E R
S T L
O U
IS
F
L O
O D P
R O
T E
C T
IO
N D
IS
T R
IC
T
S T L
O U
IS
C
IT
Y
M O
T
R U
C T
U R
A L
R
IS
E R R
E P
L A
C E
M E
N T
D E
T A
IL
S
S-101
E1
SCALE: 3/4" = 1' 2'0 1' 4'
CONSTRUCTION AND REPLACE IN KIND
REMOVE EXISTING PAVEMENT AS REQUIRED FOR
A8
E5
1'-3"
5'-6"
#5 @ 6" EW T&B
#5 DIAG. TOP ONLY
LID AND FRAME TYPE
SEE NOTE 1 FOR MANHOLE
R
E Q
D W
A L L E
X T . S
L A
B M
IN
LID AND FRAME TYPE
SEE NOTE 1 FOR MANHOLE
PROVIDE WATERSTOP. SEE NOTE 2
REMAIN IN PLACE
TO SUPPORT MANHOLE FRAME. WOOD FORMS MAY
FORM AROUND EXISTING OPENING AS REQUIRED
TO MATCH EXISTING PAVEMENT
FINISH GRADE AND SLOPE
AT EACH END
3 MIN. W/ STD HOOK
#5 @ 12" EF
W/ STD HOOK TOP
#5 @ 12" EF
AND FRAME WHERE NOTED
RISER SLAB, PRESSURE LID
REMOVE AND REPLACE EXISTING
SCALE: 1" = 1'A5
SCALE: 3/4" = 1'
EXISTING TOP SLAB
2'0 1' 4'
EXISTING PRESSURE MANHOLE SECTION
R
IS
E R
5'-2"
DEMO LINE.
SAW CUT AT
EXISTING RISER.
AT BOTTOM OF
DEMOLITION LIMITS
5'-2"
C5 SCALE: 3/4" = 1'
EXISTING SECTION
2'0 1' 4'
5'-2"
RISER REPLACEMENT SECTIONRISER REPLACEMENT PLAN
AND FRAME
EXISTING FRAME AND INSTALL NEW PRESSURE LID
FRAME WHERE NOTED. REMOVE CONCRETE AROUND
REMOVE AND REPLACE ONLY PRESSURE LID AND
TO MATCH EXISTING PAVEMENT
FINISH GRADE AND SLOPE
LID AND FRAME TYPE
SEE NOTE 1 FOR MANHOLE
CONSTRUCTION AND REPLACE IN KIND
REMOVE EXISTING PAVEMENT AS REQUIRED FOR
W/ STD HOOK TOP
#5 @ 12" EF
AT EACH END
3 MIN. W/ STD HOOK
#5 @ 12" EF
PROVIDE WATERSTOP. SEE NOTE 2
REMAIN IN PLACE
TO SUPPORT MANHOLE FRAME. WOOD FORMS MAY
FORM AROUND EXISTING OPENING AS REQUIRED
R
E Q
D W
A L L E
X T . S
L A
B M
IN
A1
CIRCULAR RISER REPLACEMENT SECTION
C1
#5 @ 6" EW T&B
#5 DIAG. TOP ONLY
LID AND FRAME TYPE
SEE NOTE 1 FOR MANHOLE
CIRCULAR RISER REPLACEMENT PLAN
5'-6"
1'-3"
ONLY WHERE EXISTING RISER IS CIRCULAR
NOTE: CIRCULAR RISER TO BE USED
0 1' 2'6"
P L -9
F
L O
O D R
E C
O V
E R
Y S
E W
E R S
Y S
T E
M R
E P
A
IR
S L S
W
IT
Z E
R
L S
W
IT
Z E
R
SEE NOTE 5
CIPM REHAB, THEN REPLACE.
REMOVE STEPS PRIOR TO
RECOMMENDATIONS
STEPS IN ACCORDANCE WITH SPECIFICATIONS AND MANUFACTURERS
SEE SPECIFICATION 33 01 30.72 FOR MANHOLE STEP REMOVAL. REPLACE 5.
SEE AS-BUILTS FOR DETAILS AND DIMENSIONS AT EACH LOCATION
PRESSURE LID AND FRAME REPLACEMENTS UNLESS OTHERWISE NOTED.
USE GENERAL DETAILS BELOW FOR ALL RISER REPLACEMENTS AND 4.
SEE SPECIFICATION 03 30 00 FOR EPOXY ANCHORAGE REQUIREMENTS.3.
REQUIREMENTS
SEE SPECIFICATION 33 40 00 FOR WATERSTOP STIP2.
AND FRAME REQUIREMENTS
1. SEE SPECIFICATION 33 40 00 FOR PRESSURE LID
SHEET NOTES
12" MIN. EMBED. SEE NOTE 3
DRILL AND EPOXY GROUT WITH
@ 12" CTRD ON EXIST 4 WALLS.
#5 DWL W/ STD HOOK TOP
12" MIN. EMBED. SEE NOTE 3
DRILL AND EPOXY GROUT WITH
@ 12" CTRD ON EXIST 4 WALLS.
#5 DWL W/ STD HOOK TOP
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
A5
S-101
E5
S-101
A1
S-101
| M-SL-01_G-001_COV |
| M-SL-01_G-002_GEN |
| M-SL-01_G-101_LOC |
| M-SL-01_C-101PLN_ |
| M-SL-01_C-102PLN_ |
| M-SL-01_C-103PLN_ |
| M-SL-01_C-104PLN_ |
| M-SL-01_C-105PLN_ |
| M-SL-01_C-106PLN_ |
| M-SL-01_C-107PLN_ |
| M-SL-01_C-108PLN_ |
| M-SL-01_C-109PLN_ |
| M-SL-01_C-110PLN_ |
| M-SL-01_C-111PLN_ |
| M-SL-01_C-112PLN_ |
| M-SL-01_C-113PLN_ |
| M-SL-01_C-114PLN_ |
| M-SL-01_C-115PLN_ |
| M-SL-01_C-116PLN_ |
| M-SL-01_C-117PLN_ |
| M-SL-01_C-118PLN_ |
| M-SL-01_C-119PLN_ |
| M-SL-01_C-120PLN_ |
| M-SL-01_C-121PLN_ |
| M-SL-01_C-122PLN_ |
| M-SL-01_C-501 |
| M-SL-01_R-001PLN_ |
| M-SL-01_R-002PLN_ |
| M-SL-01_R-101PLN_ |
| M-SL-01_R-102PLN_ |
| M-SL-01_R-103PLN_ |
| M-SL-01_R-104PLN_ |
| M-SL-01_R-105PLN_ |
| M-SL-01_R-106PLN_ |
| M-SL-01_R-107PLN_ |
| M-SL-01_R-108PLN_ |
| M-SL-01_R-109PLN_ |
| M-SL-01_R-110PLN_ |
| M-SL-01_R-111PLN_ |
| M-SL-01_R-112PLN_ |
| M-SL-01_R-113PLN_ |
| M-SL-01_R-114PLN_ |
| M-SL-01_R-115PLN_ |
File details come from the government source that posted it. Updated .