Am_0001_Dumaine_Floodwall.pdf

PDF 8 MB Posted

Attached to
Mississippi River Levees - Dumaine Street
Solicitation number
W912P8-17-B-0031
Issued by

About this file

Amendment 0001

View the file

Other files

File Type Posted
W912P817B0031_Abstract.pdf PDF
Am_0004.pdf PDF
Am_0003.pdf PDF
Am_0002_Dumaine_Floodwall.pdf PDF
H847743_Part_II_-_Reference_Drawings.pdf PDF
Solicitation_-_W912P8-17-B-0031.pdf PDF
H847743_Part_I_-_Construction_Drawings.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The above numbered solicitation is hereby amended to incorporate changes as show n on the follow ing pages and to respond to contractor questions.

Additional contractor questions w ill only be accepted through Friday, 8 September 2017 to allow time for the Government's response.

BID OPENING DATE OF 20 SEPTEMBER 2017, 2:00 PM LOCAL TIME REMAINS UNCHANGED.

Please note the change in Room Number for receipt of bids in Block 6 of the SF 30.

1. CONTRACT ID CODE PAGE OF PAGES

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 07-Sep-2017

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912P817B0031

X 9B. DATED (SEE ITEM 11)

18-Aug-2017

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

07-Sep-2017

CODE

USACE, CONTRACTING DIVISION

ATTN: CEMVN-CT, ROOM 326

7400 LEAKE AVE.

NEW ORLEANS LA 70118-3651

W912P8 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

SECTION 00010

Delete pages 00010-3 and 4 in their entirety and substitute the attached revised pages 00010-3 and 4 therefor.

SECTION 01100

1. Page 14, paragraph 10. Delete this paragraph in its entirety and substitute the following therefor:

“10. PERMISSIBLE HOURS OF WORK

Normal permissible hours of work shall be between 7:00 a.m. and 7:00 p.m. The Contractor will be allowed to work on Saturdays, Sundays, or holidays when he is given permission by the Contracting Officer with coordination from the French Market Corporation. Prior to 7:00 a.m., the Contractor shall not start up equipment nor have any trucks for delivery, service, hauling, etc., arrive at the jobsite. When the Contractor is given permission to work on weekends or holidays, notice shall be given to the on-site Government personnel at least 36 hours in advance of commencement of such operations to permit suitable arrangements for inspections to be made. Adequate illumination is required after sunset and up to 7:00 p.m. to provide for a safe operating environment that allows thorough inspection of night operations.

The cost of illumination shall be at the Contractor's own expense. This contract will include 12 days of work stoppage. During these stoppage times all construction activities shall cease.

The Contractor shall plan around these work stoppage times accordingly. The work stoppage schedule will be as follows:

New Year’s Eve and New Year's Day (until 10 a.m.)

Mardi Gras – 3 days prior and 1 day after

French Quarter Fest – 2 days prior and 1 day after

Irish Italian Parade – 1 day prior and after

Creole Tomato Festival Weekend - 2 days prior and 1 day after

4th of July - day of only

Satchmo Festival Weekend - 2 days prior and 1 day after”

2. Page 22, paragraph 19. Delete this paragraph in its entirety and substitute the following therefor:

“19. VIBRATION MONITORING

Vibrations associated with any construction activity shall be limited to a peak particle velocity of 0.25 inches per second. When vibrations from the Contractor’s construction operations have exceeded the limit, the Contractor shall take immediate action to reduce the vibrations to acceptable limits.”

SECTION 02 41 00

Page 7, paragraph 3.2.2. In the 15th line, change “canal” to “floodwall”.

Page 8, paragraph 3.2.5. . In the 4th line, change “4.0 kips” to “5 kips”.

SECTION 32 12 16.00 10

Page 3, paragraph 1.2.1. Delete this paragraph in its entirety and substitute the following therefor:

1.2.1 Temporary Asphaltic Paving

No measurement will be made for asphalt paving for the temporary parking lot egress.

Payment will be made at the contract job price for "Temporary Road Construction". Price and payment shall constitute full payment for furnishing all plant, labor, equipment and materials required for placement of the temporary asphaltic pavement as applicable; testing, maintenance as required, removal after construction, installation and removal of traffic control barriers, temporary stripping, removal and replacement of parking lot bollards, and other incidental work for maintaining construction access and parking lot egress, all as specified herein and as shown on the drawings.

DRAWINGS

SHEET IDENTIFICATION Nos. G-004, C-115, C-116, S-106, S-110, S-115 and S-121. Delete these drawings in their entirety and substitute the attached revised drawings, SHEET IDENTIFICATION Nos. G-004, C-115, C-116, S-106, S-110, S-115 and S-121 therefor.

00010-3 Ed xx-xxx

SECTION 00010 – BIDDING SCHEDULE

East Bank, Mississippi River Floodwall, Mississippi River and Tributaries (MR&T), Orleans Levee District, Dumaine Street Floodwall, Sta. 492+55 to 496+55, Orleans Parish, Louisiana

Item DESCRIPTION Estimated Quantity Unit Unit Price Estimated Amount

0001 Mobilization and Demobilization 1 JOB

0002 Safety Fence 1 JOB

0003 Traffic Control and Coordination 1 JOB

0004 Maintenance and Diversion of Storm Water 1 JOB

0005 Reinforced Concrete Floodwall 1 JOB

0006 Modification to Swing Gate 1 JOB

0007 Miscellaneous Metalwork 1 JOB

0008 Separator Geotextile 950 SY

0009 Structural Excavation and Backfill 1 JOB

0010 Granular Backfill 1 JOB

0011* Sheet Pile PZ 22 7,500 SF

0012* Steel Pipe Pile 7,720 LF

0013 Granular Base Course 1 JOB

0014 Temporary Road Construction 1 JOB

0015 Asphalt Concrete - Binder Course 205 TON

0016 Asphalt Concrete - Wearing Course 930 SY

0017 Cold Planing 2,150 SY

0018 Concrete Sidewalks 275 SY

0019 Concrete Barrier Curbs and Gutters 820 LF

0020 Concrete Steps and Support Walls 1 JOB

0021 Pavement Markings 1 JOB

0022 Temporary Retaining Structures 1 JOB

0023 Storm Drainage System 1 JOB

00010-4 Ed 13-028

0024 Demolition 1 JOB

0025 Electrical Work 1 JOB

0026 Temporary Lighting 1 JOB

TOTAL: $

* Denotes a change from the previous Bidding Schedule.

**The unit "JOB" as used in this Bidding Schedule is synonymous with the term "Lump Sum" used elsewhere within these plans and specifications.

Award will be made as a whole to one bidder.

NOTE 1: Bidders shall furnish unit prices for each item listed in the Schedule requiring a unit price. If the bidder fails to insert a unit price in the appropriate blank for required item(s), but does furnish an extended total, or an estimated amount for such item(s), the Government shall deem the unit price to be the quotient obtained by dividing the extended amount for that line item by the quantity. IF A BIDDER OMITS BOTH THE UNIT PRICE AND THE EXTENDED

TOTAL OR ESTIMATED AMOUNT FOR ANY ITEM, ITS BID SHALL BE

DECLARED NON-RESPONSIVE AND THEREFORE INELIGIBLE FOR

AWARD.

NOTE 2: Any bid may be rejected if the Contracting Officer determines in writing that it is unreasonable as to price. Unreasonableness of price includes not only total price of bid, but the price for individual line items as well. Any bid may be rejected if the prices for any line items or sub line items are materially unbalanced (See FAR 14.404-2, Rejection of Individual Bids).

NOTE 3: THE NOTICE TO PROCEED (NTP): The successful bidder is advised that performance and payment bonds shall be submitted in accordance with the time frame in block 12B of SF 1442. The NTP will be issued immediately after verification of acceptable performance and payment bonds. Within seven (7) days after issuance of the NTP, the Contractor shall initiate a meeting to discuss the submittal process with the Area or Resident Engineer or his authorized representative. Physical work cannot start until the Accident Prevention Plan, Contractor Quality Control Plan, and other submittals which may be required, have been submitted and approved and all preliminary meetings called for under the contract, have been conducted.

NOTE 4: RAPID VENDOR PAYMENT: Web based instructions for the submission of invoices;

http://www.mvn.usace.army.mil/BusinessWithUs/Contracting/RapidVendorPaym ent.aspx http://www.mvn.usace.army.mil/BusinessWithUs/Contracting/RapidVendorPayment.aspx http://www.mvn.usace.army.mil/BusinessWithUs/Contracting/RapidVendorPayment.aspx

QUESTIONS AND ANSWERS

1. 01100-5 (l) states, “The Contractor shall employ a minimum of one competent person at each project site to function as the SSHO (primary), depending on job complexity, size and any other pertinent factors. The SSHO shall: Be a full-time responsibility.” Does this project constitute the size and complexity to justify a person for the full time roll of Site Safety Health Officer?

RESPONSE: Yes, the SSHO shall be a separate full-time person.

2. What size concrete piles are to be removed?

RESPONSE: Concrete piles are 12-inch square, with a tapered tip. The bottom 12-inches of the pile is tapered. Piles lengths are 15-ft for monoliths 86-94 and 23-ft for monoliths 74-85. Refer to R-011 and R-012 for monolith numbering.

3. Is there a test pile program intended for this project?

RESPONSE: No.

4. We respectfully request a CAD file for the referenced project as well.

RESPONSE: CAD files will not be provided.

5. Sheets C-120 to C-122 shows concrete barriers (jersey walls) on the land side of the travel lane.

Does the edge of parking lot (river side) require the barriers?

RESPONSE: No, riverside edge of parking lot already has a curb and bollard/chain system to keep vehicles within the travel lane.

6. Will water filled barriers be allowed in lieu of the concrete barriers in this area?

RESPONSE: Yes, provided they can be easily moved, when needed to be shifted, during construction.

7. Can we be provided with the Government’s quantities on lump sum items?

RESPONSE: Yes. See Section 00700, 52.236-4(e).

8. Please clarify the scope of Bid Item 0014 Temporary Road Construction?

RESPONSE: This will be clarified in the amendment. This item will cover the installation of the traffic control barriers, stripping, removal and replace of the bollards, and other miscellaneous parking lot modifications to accommodate construction access and parking lot egress.

9. Ref. Section 09 97 02.03 12 par. 3.6, System no. 6 – Please clarify the difference in painting limits for vertical (shop 15” from top/field coat to within 6” from top) and batter (shop 6” from top/no field coating required) pipe piles?

RESPONSE: This is to allow for the welding of the tension connector to the vertical piling without interfering with the coating. Once tension connector is welded to the pile, then field coating shall be applied up to 6-inches from the top. Battered piling do not require a tension connector.

10. Spec. 01100-22, What is the extent of the area around the project site that video and photo documentation are to be performed?

RESPONSE: The contractor should be responsible for making the determination of the preconstruction videos and photo documentation based on his proposed operations, however, as a minimum the contractor should document the conditions of existing structures, utilities and facilities within 100 feet of proposed floodwall construction. Contractor shall also document the condition of the designated access route for the project.

11. Spec. 01100-22, Will the USACE perform inspection and documentation of the interiors of any of the nearby structures?

RESPONSE: No.

12. Spec. 01100-23, In the event that damage occurs to nearby structures, roads and/or utilities and the vibration limits are not exceeded, who is responsible for the costs of repairs?

RESPONSE: Interested bidders who have any questions about potential legal liability in the performance of any aspect the contract work should consult their own legal counsel for advice.

13. Spec. 01100-23, Vibration limits are provided for various types of structures. Please indicate the locations of the nearest soil founded structure, pile founded structure and utility crossing.

RESPONSE: All vibrations will be limited to a peak particle velocity of 0.25 inches per second. This will be clarified by amendment.

14. Spec. 01100-25, The first paragraph states that the contractor shall not demolish more than 2 monoliths at one time. At what point can additional monoliths be demolished? i.e. can they be demolished once TFP is established or do the new monoliths need be fully constructed and cured?

RESPONSE: Once the new monoliths have been placed and have achieved a minimum 75% of the design strength, then additional monoliths can be demolished.

15. Spec. 31 62 17.00 12, 3.1.1 states that “Contractor shall use equipment for pile driving that will not require the de-energizing of the overhead Entergy transmission lines.” Please provide height profile of electrical lines that may impact pile driving.

RESPONSE: The lowest point of the transmission line at the project site is approximately 80 feet above the ground. As per Section 01100-9(d)(1), the Contractor shall confirm the height of the power line.

16. Spec. 31 62 17.00 12, 3.1.1, If vibrations from driving the steel pipe piling with an impact hammer exceed allowable limits, what methods will be allowed for pile installation?

RESPONSE: The Contractor shall determine how to reduce vibrations from pile driving operations.

17. Spec. 31 62 17.00 12, 3.1.1, Is pre-drilling allowed?

RESPONSE: No, as per Section 31 62 17.00 12, paragraph 3.1.5.2.

18. Spec. 31 62 17.00 12, 3.1.1.1, last sentence, states “At least one intermediate support of the pile in the template is required…” Please confirm that this is not required if the contractor provides intermediate supports in leads as stated in the 3rd sentence of this section.

RESPONSE: A support in the template is not required if there is an intermediate support in the leads.

NEW ORLEANS DISTRICT

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

N E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

:1

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

H

G -0 d g n

G E

N E

R A

L N

O T

E S

G-004

STEEL NOTES:

CONTRACTOR FOR APPROVAL.

SHALL BE SHOWN ON THE SHOP DRAWINGS AND SUBMITTED BY THE

INDICATE THE SIZE AND TYPE OF WELD ONLY. DETAILED INFO.

2. WELDING SYMBOLS SHOWN ARE THOSE ADOPTED BY ANSI AND

CONTACT, UNLESS OTHERWISE NOTED.

RUNNING A CONTINUOUS FILLET WELD ALONG ALL EDGES OF THE

CONTACT, ALL SUCH CONTACTS SHALL BE SEALED WATERTIGHT BY

1. TO PREVENT CORROSION BY MOISTURE BETWEEN STEEL SURFACES IN

R

E V

IS

E D N

O T

E S

E P

T

C

B W

NOTES:

BASIC TABLE ALTERNATE TABLE

BAR SIZE

MINIMUM EMBEDMENT MINIMUM LAP LENGTH

LENGTH, INCHES INCHES

TOP OTHER TOP OTHER TOP OTHER OTHERTOP

18 14

25 19

31 24

37 28

54 42

62 47

69 53

77 59

85 65

24 18

32 25

40 31

48 37

70 54

80 62

90 69

110 85

12 12

15 12

18 14

22 17

32 25

37 28

42 32

46 36

51 39

14 12

19 15

24 18

29 22

42 32

48 37

54 42

60 46

66 51

REINFORCEMENT EMBEDMENT AND SPLICE TABLES - 4000 PSI

EXTERNAL CORNERS, AND VERTICAL EXPANSION JOINTS.

10. REINFORCING BARS SHALL BE CONTINUOUS AT ALL CORNERS UNLESS OTHERWISE NOTED.

MUST BE AT LEAST 2 BAR DIAMETERS.

B) DISTANCE FROM THE CENTER OF A BAR TO THE NEAREST CONCRETE SURFACE

A) CENTER-TO-CENTER BAR SPACING LATERALLY IS AT LEAST 3 BAR DIAMETERS.

1. USE THE BASIC TABLE IF ALL THE FOLLOWING CONDITIONS ARE MET:

MUST BE AT LEAST 2.5 BAR DIAMETERS.

B) DISTANCE FROM THE CENTER OF A BAR TO THE NEAREST CONCRETE SURFACE

A) CENTER-TO-CENTER BAR SPACING LATERALLY IS AT LEAST 5 BAR DIAMETERS.

2. THE ALTERNATE TABLE MAY BE USED IF ALL OF THE FOLLOWING CONDITIONS ARE MET:

APPROPRIATE GUIDANCE.

TO-CENTER BAR SPACING LATERALLY IS LESS THAN 3 BAR DIAMETERS, SEE ACI 318 FOR

3. IF CONCRETE COVER OR EDGE DISTANCE IS LESS THAN 1 BAR DIAMETER OF THE CENTER-

OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.

RESPECT TO A HORIZONTAL PLANE WHICH ARE PLACED SUCH THAT MORE THAN 12 INCHES

4. TOP BARS ARE HORIZONTAL BARS AND BARS INCLINED LESS THAN 45 DEGREES WITH

BARS. IF EPOXY-COATED BARS ARE USED, SEE ACI 318 FOR ADDITIONAL CONSIDERATIONS.

5. THE TABLES SHOWN ABOVE ARE FOR NORMAL WEIGHT CONCRETE AND UNCOATED REINFORCING

MINIMUM EMBEDMENT MINIMUM LAP LENGTH

LENGTH, INCHES INCHES

SURFACES SHALL BE GIVEN A FLOAT FINISH, UNLESS OTHERWISE NOTED.

OTHERWISE INDICATED OR AS SHOWN ON THE DRAWINGS SHALL BE AS FOLLOWS:

OFFICER.

OTHER OBSTRUCTIONS, SHALL BE BENT OR SHIFTED AS DIRECTED BY THE CONTRACTING

11. REINFORCEMENT, WHERE NECESSARY TO AVOID OPENINGS, PIPES, EMBEDDED ITEMS AND

CONSTRUCTION JOINTS SHALL BE PLACED AT LOCATIONS LEAST LIKEY TO IMPAIR

THE INTEGRITY OF THE CONCRETE STRUCTURE. CONSTRUCTION JOINT

LOCATIONS SHALL BE APPROVED BY THE CONTRACTING OFFICER.

ELECTRICAL CONDUIT LAYOUT.

12. CONCRETE REINFORCEMENT LAYOUT SHALL BE COORDINATED WITH MECHANICAL AND

GENERAL NOTES:

MAINTENANCE OF TRAFFIC:

6. UNLESS OTHERWISE NOTED, PROVIDE 3/4" CHAMFER AT ALL EXPOSED JOINTS, EDGES,

ACCORDANCE WITH SP-66(04), AMERICAN CONCRETE INSTITUTE DETAILING MANUAL - LATEST EDITION.

8. ALL BENDS OF REINFORCEMENT AND ALL BAR SPACERS AND SUPPORTS SHALL BE IN

CONCRETE REINFORCING STEEL INSTITUTE.

9. REINFORCING BAR DESIGNATION NUMBERS CONFORM TO THE NUMBERING SYSTEM OF THE

5. CONSTRUCTION JOINTS SHALL BE PROVIDED WHERE SHOWN. WHERE NOT SHOWN,

4. ALL WALKWAY SURFACES SHALL BE GIVEN A BROOM FINISH. ALL OTHER UNFORMED

3. REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH (Fy) OF 60,000 PSI.

2500 PSI AT 28 DAYS, 90 DAYS IF POZZOLAN IS USED.

2. STABILIZATION SLAB CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF

28 DAYS, 90 DAYS IF POZZOLAN IS USED, UNLESS OTHERWISE NOTED.

1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 4000 PSI AT

CONCRETE NOTES:

1. THE CONTRACTING OFFICER SHALL APPROVE ALL TRAFFIC CONTROL PLANS, WITH

RECOMMENDATION FROM CITY OF NEW ORLEANS DEPARMENT OF PUBLIC WORKS.

2. THE CONTRACTOR SHALL INSTALL THE TRAFFIC CONTROL MEASURES AT THE

LOCATION(S) SHOWN ON THE PLANS.

3. THE CONSTRUCTION OF THE TRAFFIC LANES SHALL BE DONE PRIOR TO THE

CONSTRUCTION OF FLOODWALLS.

4. THE CONTRACTOR SHALL SUBMIT ALL NECESSARY CONSTRUCTION DRAWINGS,

SCHEDULES, ETC. TO THE CONTRACTING OFFICER 30 DAYS PRIOR TO

CONSTRUCTION, FOR APPROVAL.

5. THE CONTRACTOR SHALL MAINTAIN THE TRAFFIC CONTROL LANES INCLUDING SIGNS

AND BARRICADES, THROUGHOUT THE DURATION OF THE CONTRACT AS APPROVED

BY CONTRACTING OFFICER.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING THE TRAFFIC

CONTROL SIGNS AND DISPOSING OF ALL MATERIAL TO AN OFF-SITE LOCATION.

7. ALL TRAFFIC CONTROL DETAILS ARE BASED ON THE CITY OF NEW ORLEANS DEPARMENT

OF PUBLIC WORKS STANDARDS AND MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)

GUIDE-LINES.

CLEAR COVER FOR REINFORCEMENT IN ALL OTHER STRUCTURES

SHALL BE AS INDICATED OR AS SHOWN ON THE DRAWINGS.

A. ALL SURFACES TO BE IN DIRECT CONTACT WITH EARTH - 3 INCHES.

7. MINIMUM CLEAR COVER FOR ALL REINFORCEMENT IN THE FLOODWALL MONOLITH EXCEPT AS

B. ALL OTHER FORMED SURFACES - 2 INCHES.

1. ELEVATIONS ARE IN FEET AND REFER TO NORTH AMERICAN VERTICAL DATUM

(NAVD88, 2004.65).

2. DIMENSIONS AND/OR ELEVATIONS MARKED THUS (+/-) ARE APPROXIMATE. THEREFORE

CONTRACTOR SHALL VERIFY ACTUAL DIMENSIONS IN FIELD.

3. DIMENSIONS AND/OR ELEVATIONS MARKED (N.T.S.) ARE NOT SHOWN TO SCALE.

DRAWINGS ARE GENERALLY DRAWN TO SCALE BUT SHOULD NOT BE SCALED.

4. BENCHMARKS AND BASELINES HAVE BEEN ESTABLISHED BY THE GOVERNMENT AND

THE STATE PLAN ZONE HAS BEEN IMPLEMENTED. CONTRACTOR SHALL VERIFY

ESTABLISHMENT OF PROJECT BASELINE AT THE PROJECT SITE AND REESTABLISH

THE BASELINE AS REQUIRED BEFORE BEGINNING WORK. ALL UNITS ARE IN SURVEY FEET.

5. FOR BORING LOGS AND LOCATIONS, SEE SHEET NO. B-001.

6. ALL STATIONS ARE W/L STATIONS UNLESS OTHERWISE NOTED.

7. THE TERMS "FLOODWALL" AND "T-WALL" ARE SYNONYMOUS.

8. ALL KNOWN UTILITIES ARE SHOWN ON SHEET NO.C-111 AND C-112. TABLES FOR EACH

UTILITY ARE LISTED ON SHEET NO. C-110. CONTRACTOR SHALL FIELD VERIFY LOCATION OF

UTILITIES. ANY DAMAGE BY THE CONTRACTOR TO UTILITIES SHALL BE REPAIRED AT NO

ADDITIONAL COST TO THE GOVERNMENT.

9. THE CONTRACTOR SHALL LEAVE THE PROJECT SITE CLEAN AND REMOVE ALL TRASH FROM

WITHIN THE PROJECT LIMITS PRIOR TO THE END OF THE CONTRACT.

10. THE CONTRACTOR SHALL KEEP ALL LOCAL ROAD USED FOR ACCESS CLEAN DURING

CONSTRUCTION. THE CONTRACTOR SHALL HAVE WASH RACKS, SWEEPERS AND SCRAPERS

ONSITE. ALL MUD, DEBRIS ETC. SHALL BE CLEANED EACH DAY.

11. ONCE MOBILIZED TO THE JOB SITE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE

MAINTENANCE OF THE ENTIRE LEVEE (FLOODSIDE, PROTECTED SIDE, AND BERMS)

THROUGHOUT THE LIMITS OF THE PROJECT, UNTIL THE COMPLETED PROJECT

IS TURNED OVER IN ITS ENTIRETY TO THE NON FEDERAL SPONSOR (NFS).

12. ALL ROAD AND PARKING LOTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY

OF NEW ORLEANS DEPARTMENT OF PUBLIC WORKS STANDARDS.

13. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION ACITIVIES DURING EVENTS IN THE AREA

WITH THE CONTRACTING OFFICER'S REPRESENTATIVE AND THE CITY OF NEW ORLEANS.

8. THE CONTRACTOR SHALL PROVIDE UNIMPEDED SAFE ACCESS FOR PEDESTRIANS AND OWNERS TO

BUSINESSES WITHIN AND AROUND THE CONSTRUCTION ACCESS AT ALL TIMES DURING

CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE TEMPORARY SIGNAGE FOR PEDESTRIANS

DIRECTING THEM TO THE OPEN POINTS OF ACCESS. ALL TEMPORARY WALKWAYS SHALL BE

ASPHALT PAVING OR CONCRETE.

9. FLAGMEN SHALL BE USED TO DIRECT VEHICLES WHENEVER THE CONDITIONS IN THE

CONSTRUCTION ZONE REQUIRE THEM.

10. THE CONTRACTOR SHALL CONDUCT HIS OPERATIONS IN SUCH A MANNER AS TO

CAUSE THE LEAST AMOUNT OF INTERFERENCE WITH TRAFFIC IN THE VICINITY

OF THE PROJECT.

11. ALL LANES SHALL BE MINIMUM OF 10 FEET WIDE TO THE NEAR FACE OF THE

CHANNELING.

AND SURFACES COVERED BY BACKFILL SHALL BE CLASS "D" FINISH, UNLESS OTHERWISE NOTED.

14. ALL EXTERIOR FORMED SURFACES NOT COVERED BY BACKFILL SHALL BE CLASS "A" FINISH

AT THE CONTRACTOR'S EXPENSE.

OTHER THAN ANY ADDITIONAL SPLICES REQUIRED BY THE CONTRACTING OFFICER, WILL BE

THE CONTRACTING OFFICER. SPLICES OTHER THAN THOSE SHOWN ON THE DRAWINGS AND

IN THE DRAWINGS, WHERE ESSENTIAL TO CONSTRUCTIBILITY, SUBJECT TO APPROVAL BY

THE CONTRACTOR WILL BE ALLOWED TO MAKE SPLICES IN ADDITION TO THOSE INDICATED

SMALLER DIAMETER BAR OR THE DEVELOPMENT LENGTH OF THE LARGER DIAMETER BAR.

FOR BARS OF DIFFERENT SIZES SHALL BE THE LARGER OF, THE LAP SPLICE LENGTH OF THE

EMBEDMENT LENGTHS WHERE LENGTHS ARE NOT OTHERWISE INDICATED. SPLICE LENGTH

13. THE EMBEDMENT AND SPLICE TABLE SHALL BE USED IN DETERMINING LAP SPLICES AND

O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

H

C -1 d g n

C-115

SCALE: 1" = 10'-0"

SCALE: HORZ. 1" = 10'-0"

N. PETERS ST.

VAULT VALVE

N

P

TO ALL OTHER STRUCTURES.

NOTE: DRAINLINE TO HAVE A MINIMUM OF 4" CLEARANCE

FOR DETAILS)

(C-124 AND C-125

PARKING LOT

MONOLITHS

NEW T-WALL

MONOLITHS

NEW T-WALL

MONOLITHS

NEW T-WALL

NEW PLAN

NEW PROFILE

W/L

M2

M1

M3 M4 M5

PI #1 W/L

PI #2

AND R-019 FOR DETAILS)

CONSTRUCTION (SEE R-017

REPLACED IN KIND AFTER

5" CONCRETE CURB TO BE

M A

T C

H L

IN

E B /L S

T A S

E E S

H E

E T C -1

M A

T C

H L

IN

E B /L S

T A S

E E S

H E

E T C -1

PARKING LOT TO BE REPLACED OR RESURFACED.

SEE C-301 THRU C-305 FOR PORTIONS OF

PARKING LOT NOTE:

(1 O

F

N E

W P

L A

N A

N D P

R O

F

IL

BE REPLACED

AND RAMP TO

HAND RAILING

(TYP) BY OTHERS

NEW ACCENTS LIGHTS

(SEE R-018)

STEPS TO BE REPLACED

SIDEWALK TO BE REPLACED

R

E V

IS

E D S

H E

E T P

IL

E T

IP

C B

W S

E P

T

TOP OF NEW T-WALL EL. 22.6

TOP OF NEW T-WALL SLAB EL. 8.5

BOTTOM OF NEW T-WALL EL. 5.5

-5

-10

B /L S

T A

0+00 2+001+00

INV. 9.24

INV. 8.26 INV. 7.21

B /L S

T A .9

B /L S

T A .9

G A

T E S

T A

R T S

G A

T E E

N D

S

EL 12.90

TO REMAIN (INV. 7.78)

CONCRETE CURB AND RAMP

SILL

GATE

(SEE S-120)

GATE WALL ADDITION

COLUMN

GATE

INV. 2.01

INV. 8.55

GATE MONOLITH (TO REMAIN)

(INV. 6.73)

PROTECTED SIDE

VALVE VAULT ON

2% SLOPE 2% SLOPE

2% SLOPE

INV. 8.30

EL. 12.20

NEW #1 MANHOLE

TOP OF NEW T-WALL EL. 22.6

TOP OF NEW T-WALL SLAB EL. 8.5

BOTTOM OF NEW T-WALL EL. 5.5

COLUMN LIGHTS

TO BE REMOVED

AND REPLACED

A P

P R

O X

IM

A T

E

EL. 11.64

NEW CATCH BASIN

(TO REMAIN)

EL. 12.09'

CATCH BASIN

EXISTING

EL. 12.13

NEW CATCH BASIN EL. 14.80

WALL FACE

SURFACE AT

FINAL FS GROUND

(SEE E-202)

(TYP.)

MOUNTED LIGHT

NEW WALL

STEEL SHEET PILE

NEW PZ-22

TIP EL. -14.0

S

S

W

D

SW

E

W

W

CB

P

P

CB

P

P

P

P

D

CBCB

D

Breakline

TEMP

UNK CONDUIT

O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

-5

-10

4+50 4+003+00

B /L S

T A

EXISTING WALL TO REMAIN

(INV. 9.09)

TOP OF NEW T-WALL EL. 22.6

TOP OF NEW T-WALL SLAB EL. 8.5

BOTTOM OF NEW T-WALL EL. 5.5

BOTTOM OF EXISTING SLAB EL. 5.45 (+/-)

TOP OF EXISTING SLAB EL. 7.45 (+/-)

A P

P R

O X

IM

A T

E

EL. 12.78

NEW CATCH BASIN

1.5% SLOPE

EXISTING GROUND

EL. 14.80

STEEL SHEET PILE

NEW PZ-22

(SEE E-202)

(TYP.)

MOUNTED LIGHT

NEW WALL

TIP EL. -14.0

H

C -1 d g n

C-116

SCALE: 1" = 10'-0"

SCALE: HORZ. 1" = 10'-0"

NEW LAYOUT)

C-124 AND C-125 FOR

PARKING LOT (SEE

CONSTRUCTION INGRESS AND EGRESS

N

N. PETERS ST.

MONOLITH TO REMAIN

EXISTING FLOODGATE

M6 M7

M8

M9

W/L

TIE-IN

T-WALL TO I-WALL

NEW PLAN

NEW PROFILE

M A

T C

H L

IN

E B /L S

T A S

E E S

H E

E T C -1

M A

T C

H L

IN

E B /L S

T A S

E E S

H E

E T C -1

N E

W P

L A

N A

N D P

R O

F

IL

PARKING LOT TO BE REPLACED OR RESURFACED.

SEE C-301 THRU C-305 FOR PORTIONS OF

PARKING LOT NOTE:

NEW T-WALL MONOLITHS

C B

W S

E P

T

R

E V

IS

E D S

H E

E T P

IL

E T

IP

497+00

S

CB

CB

S

CB

E

W

P P

P P

P

CB

O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

:1

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

H S -1 d g n

S-106

SCREW JACK

SEE DETAIL FOR MONOLITH 2

T Y

P

IC

A L M

O N

O L

IT

H S

E C

T

IO

N

C B

W S

E P

T

R

E V

IS

E D P

IL

E A

N D S

H E

E T P

IL

E T

IP

E

L

RIVER SIDELAND SIDE

TYPICAL WALL SECTION

2'-0"

EL. 5.5

EL. 8.5

EL. 22.6

2.5

SCALE: 3/4" = 1'-0"

#8 @ 12"

#5 @ 12"

#9 @ 12"

#6 @ 10"

PILES

TO MISS

SPACED

#4 @ 12"

W/ TIP EL. -70.0

7'-6"1'-6"

11'-0"

2'-0"

EL. -70.0

PILE W/ TIP

#4 U-BARS @ 12'' O.C.

SHEETS

TOP OF

#6 BAR ON

NOTE 2)

EL. -14.0 (SEE

PZ-22 W/ TIP

OF LIGHTS ON FLOODWALL.

3. SEE SHEET E-202 FOR DETAILS ON ELECTRICAL CONDUIT AND MOUNTING

SHALL NOT BE MADE WITH A TORCH, AND SHALL HAVE SMOOTH EDGES.

2. HOLES REQUIRED IN THE SHEET PILE TO PASS REINFORCEMENT

1. FOR MONOLITH PLAN VIEW SEE SHEET S-101 THRU S-104.

NOTES:

T Y

P

E M

B E

D

JOINT

CONSTRUCTION

OPTIONAL

C L

R

C L

R

MONOLITH 2 SCREW

JACK AND EMBED DETAILS

SCALE: 3/4" = 1'-0"

(SEE R-027 FOR DETAILS)

SCREW JACK PEDESTAL

INTO T-WALL STEM

WITH 1'-3" EMBEDMENT

#4 U-BARS @ 6" O.C.

(REUSE EXISTING)

JACK STAND SUPPORT

AND ADJUST BASED ON FIELD ELEVATION.

PEDESTRIAN GATE SILL ELEVATION. CONFIRM

* ELEVATION TO BE THE SAME AS THE

SHOWN FOR CLARITY)

T-WALL STEM (REBAR NOT

SHOWN FOR CLARITY)

T-WALL BASE SLAB (REBAR NOT

EL 8.5

EL 12.68 *

EL 13.43 (+/-)

DETAILS)

C.R.S (SEE R-028 FOR

HIGH STRENGTH

3/4" Ø ANCHOR ROD

DETAILS)

C.R.S (SEE R-028 FOR

HIGH STRENTH

3/4" Ø ANCHOR ROD

(SEE R-028 FOR DETAILS)

BLOCKOUT IN CONCRETE

(SEE R-028 FOR DETAILS)

BLOCKOUT IN CONCRETE

H S -1 d g n

S-110

C O

N C

E P

T U

A L T

R S P

L A

N

A N

D T

F P P

L A

N

C B

W S

E P

T

A

D D

E D T

R S N

O T

E A

N D M

IN

O

R R

E V

IS

IO

N S

NEW ORLEANS DISTRICT

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

:1

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

WALER (TYP)

WALER (TYP)

WALER (TYP)

TRS NOTES:

1. WHEN BRACING AGAINST NEW FLOODWALL MONOLITHS, THE CONCRETE STRENGTH MUST

BE WITHIN 75% OF THE DESIGN STRENGTH. UNLESS ANALYSIS SHOWS MORE STRENGTH IS

NEEDED.

2. WHEN BRACING AGAINST NEW OR EXISTING FLOODWALL MONOLITHS, A PROTECTIVE 1/4"

NEOPRENE PAD MUST BE INSTALLED BETWEEN THE SHEET PILE BRACE AND THE CONCRETE.

THE CONTRACTOR WILL NOT BE ALLOWED TO ANCHOR BRACING TO THE NEW FLOODWALL STEM

ABOVE THE FINISHED GRADE. DETAILS FOR ANCHORING TO THE BASE SLAB AND WALL STEM

BELOW GRADE SHALL BE INCLUDED IN THE CONTRACTOR'S TRS DESIGN.

3. MEMBER SIZES SHOWN ARE CONCEPUAL ONLY AND THE CONTRACTOR SHALL DESIGN IN ACCORDANCE

WITH SECTION 01 53 00.02 12.

TFP NOTES:

1. SEE 01100-25 FOR REQUIREMENT FOR TFP PLACEMENT.

2. PRIOR TO FILLING THE HESCO BASKETS, FLEXIBLE STRIP

OF BUTYL RUBBER WILL BE INSTALLED AROUND THE PERIMETER

OF THE BASKETS ABUTTING THE CONCRETE WALL. THE BASKETS

WILL BE FILLED WITH SAND. THE WIRE BASKETS WILL EXPAND\

BULGE TO FORM A TIGHT SECURE SEAL AGAINST THE CONCRETE.

RIVER SIDE

(PZ-27)

TRS SHEETS

A

SCALE: 1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

SECTION

A

RIVER SIDE

LAND SIDE

T-WALL REMOVED

LAND SIDE

OPENING IN FLOODWALL

RIVER SIDE

(PZ-27)

TRS SHEETS

A

SCALE: 1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

SECTION

A

RIVER SIDE

LAND SIDE

T-WALL REMOVED

LAND SIDE

OPENING IN FLOODWALL

W36x150

CONCEPTUAL TRS PLAN

T-WALL STEM

T-WALL STEM

T-WALL STEM

T-WALL STEM

(TYP)

TRS BRACING

(TYP)

TRS BRACING

REQUIRED HESCO BASKETS

SEE NOTE 2 (TYP)

(TYP)

BRACES

INTERIOR

HSS 7x3/8

TEMPORARY FLOOD PROTECTION (TFP) PLAN

EL. 13.0±

EL. 8.5

EL. 5.5

2.5

EL. 9.5±

EL. 20.95±

MINIMUM TIP EL -23.0

EL. 13.0±

EL. 8.5

EL. 5.5

2.5

EL. 9.5±

EL. 20.95±

MINIMUM TIP EL -23.0

BASKETS

REQUIRED HESCO

SIDE OF DEMOLITION

BRACES ON EACH

SHEET PILE

TRS PZ-27 STEEL

VARIES

ON BASE SLAB

SHEET PILE TO SIT

TRS PZ-27 STEEL

SHEET PILE

TRS PZ-27 STEEL

VARIES

O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

:1

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

S-115

T -W

A L L M

O N

O L

IT

H S

P

IL

E D

E T

A

IL

S

3/16

H S -1 d g n

:1

C

B W

S E

P T

R

E V

IS

E D N

O T

E S

1/2'' THICK PLATE

18" DIA. STEEL PIPE PILE

NOTE: ABOVE PLAN IS FOR SHOWING

ANGLES BETWEEN STEEL BARS

1 1/8" DIA.STEEL BARS

WITH ACI STD. 180 HOOK

C /L P

IL

E

C/L PILE

PLAN

C/L PILE

PLAN

TYP

TYP

NOTE:

1. ALL VERTICAL PILES HAVE TENSION ANCHORS.

2. AFTER INSTALLING TENSION CONNECTORS, THE COAL TAR EPOXY SHALL BE

REPAIRED IN ACCORDANCE WITH SPECIFICATION 09 97 02.03 12.

3. ALL STEEL PIPE SHALL BE 18" DIA. WITH A 1/2" WALL THICKNESS AND SHALL CONFORM

WITH THE MATERIAL REQUIREMENTS AS STATED IN THE SPECIFICATIONS.

4. PIPE PILES SHALL BE FILLED WITH F'c= 2,500 PSI CONCRETE TO FILL ANY VOIDS THAT

REMAIN AFTER PILE DRIVING. THE CONTRACTOR MAY ELECT TO SUSPEND A POUR STOP

OF THE DRIVEN PILE. THE CONCRETE FILL FOR THE PIPE PILE SHALL BE CURED FOR

3 DAYS PRIOR TO PLACING THE CONCRETE FOR THE T-WALL BASE SLABS.

5. PIPE PILE SPLICE WELDS SHALL BE NON-DESTRUCTIVELY TESTED USING BOTH VT

AND UT FOR 100% OF THE WELD LENGTH.

6. CONTRACTOR MAY WELD BARS DIRECTLY TO PILES, SUBJECT TO APPROVAL.

GRIND FLUSH

WITH PIPE WALL

12 3/8

TENSION PILE CONNECTION DETAIL PIPE PILES

TYPE II CONNECTOR

3/16

3/16

/2

TYP

3/8

1/2'' THICK PLATE

TYP.

1'-1/8" DIA. STEEL BARS

STEEL PIPE PILE

1/2'' THICK PLATE

STEEL PIPE PILE

/2

ASTM A572 BARS

ASTM A572 BARS (TYP.)

1 1/8" DIA. STEEL BARS

A

SECTION

A

18" DIA. STEEL PIPE PILE

" BACKER RING8

33" X

ELEVATION

SEE PILE PLAN

L P

IL

E

L P

IL

E

C

C

CUT-OFF ELEVATION

VERTICAL PILE

PILE BATTER,

BOTTOM OF BASE SLAB

PILE CUT-OFF DETAIL

TYPICAL PIPE PILE SPLICE DETAIL

SCALE: N.T.S.

SCALE: N.T.S.

SCALE: N.T.S.

O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

W O

R L E

A N

S D

IS

T R

IC

T

N E

W O

R L E

A N

S L

O U

IS

IA

N A

A N

S I

D

H -8 -4

R .L .K

M .A .G

X X

X

E A

S T B

A N

K

M

IS

S

IS

S

IP

P I

R

IV

E R F

L O

O D

W A

L L

M

IS

S

IS

S

IP

P I

R

IV

E R A

N D T

R

IB

U T

A R

IE

S P

R O J E

C T (M

R

T

O R

L E

A N

S L

E V

E E D

IS

T R

IC

T

O R

L E

A N

S P

A R

IS

H L

O U

IS

IA

N A

:1

D U

M A

IN

E S

T F

L O

O D

W A

L L S

T A T

O

A .C .E

J U

N E

C R

A

IG

B

W A

U G

A M

A N P .E

W P -1

-B -0

A U

G U

S T

H S -1 d g n

S-121

D E

T A

IL

S G

A T

E M

O N

O L

IT

H R

E B

A R

OPENING SHALL BE SIMILAR.

NOTE: EXTENSION ON OPPOSITE SIDE OF GATE

C

B W

S E

P T

M

IN

O R R

E V

IS

IO

N S

E M

B E

D

"=1'-02

1SCALE: 1

(TYP.)

3" CLR.

1'-6"

MATCH EXIST.

EL. 22.6

MISS EXISTING STEEL

#4 @ 12" O.C. TO

#4 BARS AS SHOWN

(SEE NOTE 1)

CONSTRUCTION JOINT

REBAR (SEE REF-016)

EXISTING WALL AND

EL. 22.6

REBAR (SEE REF-016)

EXISTING WALL AND

#5 BARS

#3 TIES

(SEE NOTE 1)

CONSTRUCTION JOINT

AND REF-027

SEE NOTE 3

SECTION A

S-120

"=1'-02

1SCALE: 1

SECTION B

3'-0" ± (MATCH EXISTING)

S-120

LIGHTS

FOR GATE COLUMN

" CONDUIT ADDITION4

LIGHTS

FOR GATE COLUMN

" CONDUIT4

3EXISTING

(SEE NOTE 2)

HILTI HIT RE 500-SD

EMBED BARS USING

(SEE NOTE 2)

HILTI HIT RE 500-SD

EMBEDED BARS USING

PLACEMENT.

EXTENSION. REPLACE FIXTURES AND BASES AFTER

REMOVED FROM THE GATE COLUMNS PRIOR TO

3. THE EXISTING LIGHTS AND BASES WILL NEED TO BE

EMBEDDED BARS.

APPROVED METHOD PRIOR TO DRILLING TO AVOID DAMAGING

2. REMOVE PAINT WITH SAND BLASTING OR OTHER

ACI.

1. ROUGHEN EXISTING SURFACE TO 1/4'' AMPLITUDE PRE

NOTES:

ANGLE DETAIL

4"

SCALE: N.T.S.

(8" LEG)

1L8x4x

3L4x4x"2

OR DAMAGED ANGLES.

SHALL FIELD GALVANIZE ANY WELDED

AND GROUND FLUSH. THE CONTRACTOR

MUST BE WELDED TO EXISTING ANGLES

FABRICATION. ANGLE EXTENSIONS

HOT-DIP GALVANIZED AFTER

ENTIRE ANGLE ASSEMBLY TO BE

NOTE:

ANCHORS, 12" O.C. STAGGERED

"x6" WELDED2 1" W/8

3L8"x4"x

ANCHORS, 12" O.C. STRAGGERED

" x6" WELDED2 1" W/8

3L4"x4"x

AT GATE COLUMNS:

RIVER SIDE

LAND SIDE

SCALE: 1" = 1'-0"

JOINT

" EXPANSION2

#4 @ 12"

ON SECTION A

#4 AS SHOWN

AS SHOWN

#3 TIES

AS SHOWN

#5 BARS

SEE NOTE 3

TO BE REPLACED

EXISTING WALL

CSECTION

S-120

EXISTING

TO MATCH

" 8 3L 4x4x

COLUMN)

SIDE OF THE OPPOSITE

(L 8x4 IS USED ON THE SAME

" TO MATCH EXISTING 8

3L 4x4x

3'-0" 13'-0"

AS SHOWN

#4 BARS

AS SHOWN

#3 TIES

12" (TYP)

EMBED MIN.

Am_0001_Dumaine Floodwall.pdf
“10. PERMISSIBLE HOURS OF WORK
“19. VIBRATION MONITORING
1.2.1 Temporary Asphaltic Paving
ED Amendment #1 - Drawings.pdf
H847743_G-004---
H847743_C-115---
H847743_C-116---
H847743_S-106---
H847743_S-110---
H847743_S-115---
H847743_S-121---

File details come from the government source that posted it. Updated .