This notice announces a solicitation for construction services. The U.S. Army Corps of Engineers - Chicago District is seeking bids for its Markle Transformer Project located in Markle, Indiana. Under the contract, the selected contractor will install a pad mounted three-phase transformer and connecting duct back along with a new concrete pad at the JE Roush Upper Wabash Area facility. The project cost is estimated between $250,000 to $500,000. The solicitation package is available electronically only and bids are due by the date specified in the IFB document. This opportunity is restricted to small businesses with average annual revenue under $39.5 million. Interested parties must register in the System for Award Management at SAM.gov. Queries should be directed to the points of contact via email and reference the solicitation number.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
SUBSTATION
MARKLE PUMP STATION
LOCATION PLAN
NO SCALE
NO SCALE
FY
Louisville District
P2 - 128624
TRANSFORMER UPGRADE
MARKLE PUMP STATION
MARKLE, INDIANA
SOLICITATION#
CONTRACT #
ALL DRAWINGS IN THIS SET.
INDICATE OFFICIAL RECOMMENDATION OF
REQUIRED BY ER 1110-1-8152. SIGNATURES
THE SCOPE OF THEIR EMPLOYMENT AS
ON THESE PROJECT DOCUMENTS WITHIN
TION DESIGNATIONS OF INDIVIDUALS APPEAR
INITIALS OR SIGNATURES AND REGISTRA-
CHICAGO DISTRICT CORPS OF ENGINEERS. THE
THIS PROJECT WAS DESIGNED BY THE
REVIEWED BY:
DATE CHIEF, DESIGN BRANCH
APPROVED BY:
APPROVAL RECOMMENDED BY:
PROJECT MANAGER
DRAWINGS CONTAINED IN THE SHEET INDEX.
RECOMMENDATION AND APPROVAL FOR ALL
SIGNATURE AFFIXED BELOW INDICATE OFFICAL
DATE
DATE
MIKE PADILLA
JOHN GROBOSKI, P.E.
DQC TEAM LEADER
BRIAN PORTER
FY
DISPOSITION:
ARIMS: #####
Louisville District
P2 - 128624 FY 2021
TRANSFORMER UPGRADE
MARKLE PUMP STATION
MARKLE, INDIANA
CERTIFIED FINAL DOCUMENTS - RTA
W912P6-21-B0013SOLICITATION#
CONTRACT #
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:51:04 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_VA101.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
PUMP ROAD
EXISTING UTILITY POLE
EXISTING UTILITY POLE
EXISTING UTILITY POLE
JE ROUSH LAKE
EX. TRASNFORMER PAD
MARKLE PUMP
STATION BUILDING
MARKLE GENERATOR BUILDING
770770
785785
790790
GENERAL SHEET NOTES
LEGEND
PROPOSED CONTRACTOR WORK LIMITS
EX. CONCRETE - SIDEWALK
EX. CONCRETE - TRANSFORMER PAD
EX. ASPHALT PAVEMENT
EXISTING ELECTRICAL LINE
COORDINATED WITH PROJECT PERSONNEL.
6. CONTRACTOR WORK LIMITS SHOWN ARE APPROXIMATE AND SHALL BE
5. ALL DIMENSIONS ARE SHOWN IN US SURVEY FEET UNLESS INDICATED OTHERWISE.
SYSTEM (NAD83). VERTICAL DATUM IS NAVD88.
4. HORIZONTAL DATUM IS INDIANA EAST ZONE (2011) STATE PLANE COORDINATE
3. IMAGE SOURCE IS GOOGLE EARTH AND DATED 7/12/2018.
VERIFY ALL COMPONENTS OF THE SITE DETAILS.
2. ACCURACY OF INFORMATION IS NOT GUARANTEED. CONTRACTOR TO FIELD
RESPONSIBLE TO VERIFY ALL EXISTING UTILITIES.
1. PRIOR TO ANY AND ALL CONSTRUCTION, THE CONTRACTOR SHALL BE
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:51:04 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_VA101.dgn
V A .d g n
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
J E
D W
A R
D R
O U
C H L
A K
E
M A
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
J
O N
E S
J J
O N
E S
VA101
M L
A W
R E
N C
E
A1
SCALE: 1" = 10'
NORTH
10' 20'0
A E
R
IA
L P
H O
T O
G R
A P
H A
N D E
X
IS
T
IN
G S
IT
E
AERIAL PHOTOGRAPH AND EXISTING SITE CONDITIONS
C H
IC
A G
O D
IS
T R
IC
T
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O
IL
L
IN
O
IS
P R
O J E
C T I
D
F
IL
E N
A M
E
CERTIFIED FINAL DOCUMENTS - RTA
C O
N T
R A
C T N
U M
B E
R
/2
D A
V E S
C H
IE
M A
N N
W P -2
-B
PUMP ROAD
EXISTING UTILITY POLE
EXISTING UTILITY POLE
EXISTING UTILITY POLE
JE ROUSH LAKE
PAD
TRASNFORMER
EXISTING
EXISTING GUARDRAIL
BUILDING
GENERATOR
MARKLE
STATION BUILDING
MARKLE PUMP
3'
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:51:47 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CS101.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
GENERAL SHEET NOTES
SHEET KEYNOTES
LEGEND
NEW GRAVEL SHOULDER
4. NEW 6 FT SIDEWALK; SEE DETAIL ON SHEET CS501
3. NEW PERMANENT BOLLARDS; SEE DETAIL ON SHEET CS501
2. NEW GRAVEL SHOULDER; SEE DETAIL ON SHEET E-501
1. NEW CONCRETE TRANSFORMER PAD; SEE DETAIL ON SHEET E-501
NEW CONCRETE TRANSFORMER PAD
NEW CONCRETE SIDEWALK
PROPOSED CONTRACTOR WORK LIMITS
COORDINATED WITH PROJECT PERSONNEL.
9. CONTRACTOR WORK LIMITS SHOWN ARE APPROXIMATE AND SHALL BE
AT ALL TIMES FOR OPERATIONS PERSONNEL.
8. ACCESS TO THE TRANSFORMER BUILDING AND SADDLE DAM MUST BE MAINTAINED
THE GOVERNMENT.
RESPONSIBLE FOR ANY DAMAGW AND SHALL REPLACE IN KIND AT NO COST TO
SHALL BE PROTECTED DURING CONSTRUCTION.CONTRACTOR SHALL BE
7. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED FOR DEMOLITION
ADJACENT GRADES OF PUMP ROAD AND NEW CONCRETE TRANSFORMER PAD.
6. NEW 6 FT CONCTRETE SIDEWALK SURFACE SHALL BE INSTALLED TO MATCH
DETERMINED FROM EQUIPMENT DIMENSIONS.
EDGE OF NEW CONCRETE TRANSFORMER PAD ONCE FINAL PAD DIMENSIONS ARE
5. NEW PERMANENT BOLLARDS SHALL BE INSTALLED 3 FEET OFFSET FROM
ENSURE POSITIVE DRAINAGE OF 1/8":1.0' MAX AWAY FROM PUMP ROAD.
4. NEW CONCRETE TRANSFORMER PAD SURFACE SHALL BE GRADED TO
E-501.
ELECTRICAL EQUIPMENT SIZE AND IN ACCORDANCE WITH DETAILS ON SHEET
3. NEW CONCRETE TRANSFORMER PAD SHALL BE SIZED ACCORDING TO NEW
2. ALL DIMENSIONS ARE IN US SURVEY FEET, UNLESS NOTED OTHERWISE.
AND LOCAL UTILITY.
OF NEW SITE FEATURES SHALL BE COORDINATED WITH PROJECT PERSONNEL
VERIFY ALL EXISTING COMPONENTS OF THE SITE DETAILS. FINAL LOCATIONS
1. ACCURACY OF INFORMATION IS NOT GUARANTEED. CONTRACTOR TO FIELD
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:51:47 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CS101.dgn
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
CS101A1
SCALE: 1" = 10'
NORTH
SITE PLAN
10' 20'0
J E
D W
A R
D R
O U
C H L
A K
E
CERTIFIED FINAL DOCUMENTS - RTA
BUILDING
GENERATOR
MARKLE
STATION BUILDING
MARKLE PUMP
PAD
TRASNFORMER
EXISTING
A N
S I
D
C O
N T
R A
C T N
U M
B
R
P
O J E
C T I
D
F
IL
E N
A M
E
CERTIFIED FINAL DOCUMENTS - RTA
M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
CS101
J J
O N
L
A W
R E
N C
IT
E P
L A
N D
A V
E S
C H
IE
M A
N N
C S .d g n
J J
O N
E S
W P -2
-B
CONCRETE
1/8"
/4
T
1/2"
/2
EXPANSION JOINT
DUMMY GROOVE
SUBBASE
BASE AND/OR
EXISTING
CONCRETE CAP
TRAFFIC YELLOW PAINT
PAINTED WITH 2 COATS OF
FILLED WITH CONCRETE &
6" SCH.80 STEEL PIPE
T T
SEE NOTE #3
1/8" RADIUS
TOOLED EDGES
JOINT SEALANT
JOINT FILLER
PREMOULDED
PER SPEC 32 11 16
4" STONE BASE
12"
SUBBASE
AND/OR
EXIST. BASE
COURSE
EXIST. SURFACE
PRIME COAT(TYP.)
TACK COAT
WIDTH
TRENCH
MATERIAL (SEE SPECS)
TRENCH BACKFILL
SET BACK
12" MIN.
SET BACK
12" MIN.
12"
SAW CUT
SAW CUT
NEW ASPHALT.
AND REPLACE WITH
PAVMENT AS SHOWN
REMOVE EXIST.
SEE SHEET ES101 FOR LOCATION
WIDTH
SLOPES TO BE LAID BACK INCREASING
DEPTH OF INSTALLATION MAY REQUIRE
IDENTIFICATION TAPE
PLASTIC PIPE
TRACER WIRE FOR
BACKFILL AND FILL
TYPICAL PAVEMENT FINISH GRADE
COMMON FILL
12"
FINAL BACKFILL
FOR PLASTIC PIPE
BEDDING THICKNESS
MAX.
12"
MAX.
12"
O.D.
(TO 6" ABOVE PIPE)
INITIAL BACKFILL
SECTION 31 00 00.00 06
PROVIDE BEDDING IN ACCORDANCE WITH
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:52:01 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CS501.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
6"
6"
CONCRETE SIDEWALK
EXPANSION JOINT
PROFILE
1|
1|
SUB BASE
NOTE:
(M
IN
6"
NONTRAFFIC AREAS TRAFFIC AREAS
NOTE:
D
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:52:01 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CS501.dgn
CS501
D5
A5
B1
BOLLARD DETAIL
SCALE: NTS
TRENCH BACKFILL & REPAVING DETAIL
SCALE: NTS
SIDEWALK DETAIL
SCALE: NTS
CERTIFIED FINAL DOCUMENTS - RTA
NOTES
E1
BEDDING DETAIL
REQUIRED BETWEEN WALK AND ADJACENT PARALLELING CONCRETE CURB.
6. A LAYER OF 0.3 LBS. PER SQUARE FOOT OF ASPHALT SATURATED FELT IS
STRUCTURE.
5. 1/2" EXPANSION MATERIAL WHERE CONCRETE SIDEWALK ABUTS CONCRETE
4. CONTRACTION JOINTS SHALL BE 1" DEEP AND 1/8" WIDE.
OF THE SIDEWALKS.
3. CONTRACTION JOINTS SHALL BE SPACED AT INTERVALS EQUAl TO THE WIDTH
2. SIDEWALKS SHALL BE 4" THICK.
AND BACKFILL REQUIREMENTS.
02 UNDERGROUND ELECTRICAL DISTRIBUTION FOR SUBGRADE PREPARATION
REFER TO SPECIFICATIONS SECTION 32 31 13 EARTHWORK AND SECTION 33 71 1.
A N
S I
D
C O
N T
R A
C T N
U M
B
O J E
C T I
D
F
IL
E N
A M
E
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
C
IV
IL
D
E T
A
IL
S
CS501
J J
O N
L
A W
R E
N
V E S
C H
IE
M A
N N
C S .d g n
J J
O N
E S
W P -2
-B
PUMP ROAD
EXISTING UTILITY POLE
EXISTING UTILITY POLE
EXISTING UTILITY POLE
JE ROUSH LAKE
PAD
TRASNFORMER
EXISTING
EXISTING GUARDRAIL
BUILDING
GENERATOR
MARKLE
770770
785785
790790
STATION BUILDING
MARKLE PUMP
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:52:16 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CG101.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
PAD - EL. 772
NEW CONCRETE TRANSFORMER
MATCH ELEVATION OF TRANSFORMER PAD
NEW CONCRETE SIDEWALK
MATCH ELEVATION OF PUMP ROAD
NEW CONCRETE SIDEWALK
DRAINAGE TO LAKE
ENSURE POSITIVE
GENERAL SHEET NOTES
LEGEND
PROPOSED CONTRACTOR WORK LIMITS
NEW GRAVEL SHOULDER
NEW CONCRETE TRANSFORMER PAD
COORDINATED WITH PROJECT PERSONNEL.
6. CONTRACTOR WORK LIMITS SHOWN ARE APPROXIMATE AND SHALL BE
AROUND TOE OF FILL FOR NEW TRANSFORMER PAD.
5. EXISTING NATURAL DRAINAGE AT TOE OF LEVEE SHALL BE MAINTAINED
TYPICAL SECTION.
4. SEE SHEET E-501 FOR CONCRETE TRANSFORMER PAD DETAILS AND
3. CONTOUR INTERVAL IS 1.0 FT.
SHALL BE PROTECTED DURING EARTHWORK AND CONSTRUCTION.
2. EXISTING UTILITIES AND SITE STRUCTURES NOT IDENTIFIED FOR DEMOLITION
RESPONSIBLE TO VERIFY ALL EXISTING UTILITIES.
1. PRIOR TO ANY AND ALL CONSTRUCTION, THE CONTRACTOR SHALL BE
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:52:16 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_CG101.dgn
C G
.d g
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
J
O N
E S
J J
O N
E S
CG101
M L
A W
R E
N C
E
A1
SCALE: 1" = 10'
NORTH
10' 20'0
GRADING PLAN
G R
A D
IN
G P
L A
N
C H
IC
A G
O D
IS
T R
IC
T
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O
IL
L
IN
O
IS
C O
N T
R A
C T N
U M
B E
R
/2
P R
O J E
C T I
D
F
IL
E N
A M
E
J E
D W
A R
D R
O U
C H L
A K
E
M A
R K
L E T
R A
N S
F O
R M
E R R
E H
B
BUILDING
GENERATOR
MARKLE
STATION BUILDING
MARKLE PUMP
PAD
TRASNFORMER
EXISTING
D A
V E S
C H
IE
M A
N N
A N
S I
D
C O
N T
R A
C T N
U M
B
O J E
C T I
D
F
IL
E N
A M
E
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
W P -2
-B
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:52:30 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E001.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
E-001
L
A W
R E
N
GENERAL SITE NOTES ELECTRICAL SAFETY NOTES
ADVANCE.
THE ENERGIZED WORK REQUEST MUST BE PREPARED IN D.
PROTECTIVE EQUIPMENT.
EQUIPMENT AND ENSURE PROPER USE OF PERSONAL
MUST APPROVE ANY PLAN TO WORK ON ENERGIZED
A QUALIFIED SUPERVISOR MUST BE CONSULTED AND C.
USE TWO -PERSON TEAMS TO PERFORM WORK.B.
WORK IN ADVANCE.
CONTRACTING OFFICER. THE CO MUST APPROVE ENERGIZED
SUBMIT A REQUEST FOR LIVE WORK THROUGH THE A.
COMPLETED THE CONTRACTOR SHALL:
LIVE PARTS EXPOSED. IN THE EVENT THAT LIVE WORK MUST BE
WORK AREA SHALL BE PLACED IN A SAFE CONDITION WITH NO
DE-ENERGIZED PRIOR TO ENERGIZING THE EQUIPMENT, THE
ALL WORK SHALL BE COMPLETED WHILE THE FEEDERS ARE 5.
EQUIPMENT (PPE) REQUIRED TO PERFORM WORK.
CONTRACTOR SHALL FURNISH ALL PERSONAL PROTECTIVE 4.
COMPLYING WITH THE ENERGIZED WORK PERMIT.
SAFE WORKING POSITIONS, HANDLING TOOLS SAFELY, AND
CHECKING THEM CONSTANTLY TO MAKE SURE THEY ARE IN
SUPERVISOR MUST CLOSELY SUPERVISE THE WORKERS,
WHILE THE JOB IS IN PROGRESS, AN ON -SITE C.
WRITTEN SAFE CLEARANCE FORM.
OF THIS PARAGRAPH, COR APPROVAL IS GRANTED THROUGH A
ABOVE SHALL BE FOLLOWED; HOWEVER, FOR THE PURPOSES
PERFORMING "ENERGIZED WORK" AND ALL THE PROCEDURES
PURPOSE OF ISOLATING CIRCUITS IS CONSIDERED
OPERATING CIRCUIT BREAKERS/DISCONNECTS) FOR THE
OFF/ON A SWITCH, OPENING AND CLOSING SWITCHES, OR
DE-ENERGIZING/RE-ENERGIZING METHODS (I.E., TURNING
CONVENTIONAL CIRCUIT B.
ENSURE SAFETY.
SUPERVISION, TRAINING, AND PLANNING ARE PARAMOUNT TO
EQUIPMENT AND APPROPRIATE SUPERVISION. PROPER
PLACE SPECIAL EMPHASIS ON PERSONAL PROTECTIVE A.
WITHOUT MEETING THE FOLLOWING REQUIREMENTS:
STARTING. ENERGIZED WORK SHALL NOT BE ALLOWED
REVIEWED WITH ALL PERSONNEL IMMEDIATELY BEFORE
WORK PROCEDURES LISTED IN AFI 32-1064 ARE FOLLOWED AND
EXTREME CAUTION AND ONLY WHEN THE BASIC ENERGIZED
ABSOLUTELY NECESSARY, IT SHOULD BE ACCOMPLISHED WITH
ENERGIZED CIRCUITS: WHEN ENERGIZED WORK IS DEEMED 3.
PARAGRAPH 11.A.02.C. REFERENCE NFPA70E.
CONTAIN INFORMATION REQUIRED BY USACE EM 385-1-1
VIA THE CONTRACTING OFFICER FOR ACCEPTANCE AND SHALL
WORK REQUEST SHALL BE SUBMITTED TO THE GOVERNMENT
WORKED ON IN AN ENERGIZED CONDITION, AN ENERGIZED
EXIST. IF IT IS DETERMINED THAT EQUIPMENT MUST BE
CIRCUITS UNLESS PROOF IS PROVIDED THAT NO OTHER MEANS
NO WORK SHALL BE PERFORMED ON ENERGIZED ELECTRICAL 2.
BE COMPLIED WITH BY THE CONTRACTOR.
WITH EM 385-1-1 AND THE LATEST EDITION OF NFPA 70E SHALL
LOCAL ''LOCKOUT/TAG OUT' PROCEDURES IN ACCORDANCE 1.
L
A W
R E
N C
E
M .L
A W
R E
N C
E
G E
N E
R A
L E
L E
C T
R
IC
A L N
O T
E S
COST TO THE GOVERNMENT.
COMPLETION OF THE PROJECT AT NO ADDITIONAL
EQUIPMENT TO ITS ORIGINAL CONDITION AT THE
SHALL BE RESPONSIBLE FOR RETURNING THE
THE CONTRACTING OFFICER. THE CONTRACTOR
THE EQUIPMENT'S OPERABILITY IN THE PRESENCE OF
SHALL DEMONSTRATE AND DOCUMENT IN A REPORT
DESIGN. PRIOR TO REMOVAL, THE CONTRACTOR
STORED, AND RE- INSTALLED AS DESCRIBED IN THE
NOTED IN THE DESIGN SHALL BE REMOVED, SAFELY
EXISTING EQUIPMENT THAT IS TO BE RE-USED AS 25.
REPLACED AT THE CONTRACTOR'S EXPENSE.
DOCUMENTS SHALL BE COMPLETELY REMOVED AND
ANY ITEMS INSTALLED INCORRECTLY PER CONTRACT 24.
MEETINGS FOR THE DURATION OF THE PROJECT.
CONTRACTOR SHALL ATTEND ALL CONSTRUCTION 23.
CONTRACT.
(PLANS), SPECIFICATIONS, AND TERMS OF THE
THE WORK IN ACCORDANCE WITH THE DRAWINGS
TESTING AND INCIDENTALS REQUIRED TO COMPLETE
EQUIPMENT, TOOLS, TRANSPORTATION, SUPPLIES,
FURNISH ALL LABOR, SUPERVISION, MATERIALS,
FURTHER INTENDED THAT THE CONTRACTOR SHALL
DESCRIBED, UNLESS OTHERWISE NOTED. IT IS
COMPLETION IN EVERY DETAIL OF THE WORK
EQUIPMENT FOR THE CONSTRUCTION AND
THE CONTRACTOR SHALL FURNISH AND INSTALL ALL 22.
CUTTING AND PATCHING FOR THEIR WORK.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL 21.
PRIOR TO INITIATING THE WORK.
CONTRACTING OFFICER FOR REVIEW AND APPROVAL
METHODS SHALL BE SUBMITTED TO THE
SATISFACTION OF THE GOVERNMENT. ALL REPAIR
IMMEDIATELY REPAIRED WITHIN 24 HOURS TO THE
GOVERNMENT. ALL DAMAGED SYSTEMS SHALL BE
REMAIN SHALL BE AT NO ADDITIONAL COST TO THE
ANY DAMAGED EXISTING SYSTEMS/UTILITIES TO
BE PROTECTED FROM DAMAGE. REPLACEMENT OF
ALL EXISTING SYSTEMS/UTILITIES TO REMAIN SHALL 20.
OTHER GROUPS.
INSURE THAT THE WORK DOES NOT INTERFERE WITH
OTHER DISCIPLINES BEFORE BEGINNING WORK TO
THIS CONTRACT. COORDINATE THE WORK WITH ALL
PROPER SUPPORT OF EQUIPMENT FURNISHED UNDER
STRUCTURAL SUPPORTS, AND ACCESSORIES FOR
MOUNTED. PROVIDE ALL BOLTS, INSERTS, BRACKETS,
RELATED ITEMS ARE TO BE SUPPORTED OR
DETERMINE HOW EQUIPMENT, ACCESSORIES, AND
DRAWINGS, SHOP DRAWINGS, AND CATALOG DATA TO
INSTALLED UNDER THIS CONTRACT. STUDY ALL
PROPERLY SUPPORT ALL WORK AND EQUIPMENT 19.
POINT CONCERNED.
PRIOR TO THE PROGRESS OF THE WORK BEYOND THE
DISCREPANCY OR POINTS OF CONFLICT IN WRITING
CONTRACTING OFFICER WILL CLARIFY SUCH
NOTIFY THE CONTRACTING OFFICER IN WRITING .THE
DRAWINGS OR THE SPECIFICATIONS, IMMEDIATELY
DISCREPANCY OR POINTS OF CONFLICT IN THE
WITH ANY WORK. UPON DISCOVERY OF ANY
AND EXISTING CONDITIONS PRIOR TO PROCEEDING
CONTRACTOR WILL FIELD VERIFY ALL DIMENSIONS 18.
UTILITIES.
INTERFERENCE WITH OTHER EQUIPMENT AND
ADJUST EQUIPMENT AND FIXTURES TO AVOID 17.
ARRANGEMENT BEFORE INSTALLING THE EQUIPMENT.
APPROVAL WITH A PROPOSED REVISED
DRAWING TO THE CONTRACTING OFFICER FOR
NOT FIT AS SHOWN ON THE DRAWINGS, PROVIDE A
SHOWN ON THE DRAWINGS. WHERE EQUIPMENT WILL
EQUIPMENT FURNISHED WILL FIT INTO THE SPACE AS
MEASUREMENTS TO INSURE THAT ALL ITEMS OF
BEFORE INSTALLING EQUIPMENT, MAKE FIELD 16.
THE GOVERNMENT, PRIOR TO STARTING WORK.
SERVICE SHALL BE COORDINATED AND APPROVED BY
INTERRUPTION OF AN EXISTING SYSTEM OR UTILITY
LOCATION OF ALL EXISTING UTILITIES. ANY
WORK. THE CONTRACTOR SHALL STAKE/MARK THE
WORK WITH THE GOVERNMENT PRIOR TO STARTING
CONTRACTORS RESPONSIBILITY TO COORDINATE ALL
FOR EXACT LOCATIONS. IT SHALL BE THE
PLANS ARE APPROXIMATE AND SHALL NOT BE SCALED
THE EXISTING UTILITY LOCATIONS SHOWN ON THE 15.
E .d g n
P R
O J E
C T I
D
F
IL
E N
A M
E
P R
O J E
C T I
D
F
IL
E N
A M
E
X X
X X
X X
NOTED.
THE PROJECT BE REMOVED UNLESS OTHERWISE
ARE NO LONGER REQUIRED AS A RESULT OF
WIRING MATERIALS, AND SYSTEMS, ETC., WHICH
THAT ALL EQUIPMENT, DEVICES, FIXTURES,
THE INTENT OF THE DEMOLITION DRAWINGS
BUILT' DRAWINGS OF THE AREAS AFFECTED. IT IS
EXISTING CONDITIONS AND ON EXISTING ''AS-
BASED ON FIELD OBSERVATION OF THE ACTUAL
CONDITIONS AND DEMOLITION DRAWINGS ARE
ALL WORK SHOWN ON THE EXISTING 14.
AND ACCESSORIES AS MAY BE REQUIRED.
CONDITIONS AND PROVIDE SUCH EQUIPMENT
ARRANGE THE WORK TO MEET THESE
INVESTIGATED. THE CONTRACTOR SHALL
STRUCTURAL AND FINISH CONDITIONS
SHALL BE CHECKED AT THE SITE AND ALL
AND LOCATION OF EQUIPMENT. ALL DIMENSIONS
AS POSSIBLE IN THE GENERAL ARRANGEMENT
SHOULD HOWEVER BE FOLLOWED AS CLOSELY
REQUIRED FOR THE COMPLETE SYSTEM. THEY
DRAWINGS DO NOT SHOW ALL DETAILS
CONDITIONS PRIOR TO STARTING WORK. THESE
CONTRACTOR SHALL VERIFY EXISTING 13.
ENVIRONMENTAL CONDITIONS.
PROPERTIES AGAINST FIRE, THEFT, AND
RESPONSIBILITY FOR PROTECTION OF
THE JOB SITE. OWNER ASSUME NO
THE SAFEKEEPING OF HIS OWN PROPERTY ON
THE CONTRACTOR WILL BE RESPONSIBLE FOR 12.
SPRING THROUGH EARLY SUMMER.
THE PUMPING SEASON WHICH OCCURS FROM
ACCESS TO SHUT DOWN EQUIPMENT DURING
CONTRACTOR SHOULD PLAN FOR LIMITED
AND FOR HOW LONG A PERIOD OF TIME. THE
WHEN THE PROPOSED SHUTDOWN WILL OCCUR,
INDICATING WHICH AREAS WILL BE AFFECTED,
NOTICE MUST BE GIVEN TO THE OWNER
OR DISCONNECTION, SUFFICIENT ADVANCED
ARE AFFECTED BY ANY SHUTDOWN, REMOVAL
IF ANY AREAS NOT WITHIN THE SCOPE OF WORK
REMAIN IN OPERATION WILL NOT BE AFFECTED.
AND/OR ENGINEER. CONFIRM THAT AREAS TO
WITHOUT PRIOR REVIEW WITH THE OWNER
REMOVED, DISCONNECTED, OR SHUT DOWN
NO WIRING, EQUIPMENT, ETC. WILL BE 11.
WIRE.
DEDICATED NEUTRALS AND SEPARATE GROUND
ALL NEW CIRCUITS WILL BE PROVIDED WITH 10.
WILL BE BASED ON CHAPTER 9 OF THE NEC.
UNLESS OTHERWISE INDICATED, CONDUIT SIZES 9.
UNLESS OTHERWISE NOTED. SEE SPECS.
ALL CONDUCTORS WILL BE COPPER THHN/THWN, 8.
ELECTRICAL CODE.
CURRENT EDITION OF NFPA 70 - NATIONAL
ALL WIRING METHODS WILL COMPLY WITH THE 7.
BEEN AFFECTED.
BY THE CONTRACTOR WHERE FINISHES HAVE
ALL PATCHING AND FINISHING SHALL BE DONE
ALL ELECTRICAL EQUIPMENT AND MATERIALS.
NECESSARY FOR THE PROPER INSTALLATION OF
THE CONTRACTOR WILL DO ALL WORK 6.
BE USED.
WHERE CONDUIT WILL BE EXPOSED, RGS WILL
WIRING WILL BE RUN IN EMT CONDUIT. IN AREAS
BRANCH, CONTROL, AND COMMUNICATIONS
UNLESS OTHERWISE INDICATED FEEDERS, 5.
TYPE 1 (INDOOR), NEMA TYPE 3R (OUTDOOR).
ENCLOSURES FOR EQUIPMENT WILL BE NEMA
UNLESS OTHERWISE INDICATED, ALL 4.
WORK.
SURVEY THE SPACE BEFORE PERFORMING THE
REQUIRING THE CONTRACTOR TO INSPECT AND
AND/OR HIDDEN, THAT MAY EXIST; THUS
INTERFERENCES AND CONDITIONS, VISIBLE
PLANS AND DETAILS DO NOT SHOW ALL 3.
AND LOCAL GOVERNING AUTHORITIES.
WORKMEN IN ACCORDANCE WITH THE STATE
ALL WORK WILL BE DONE WITH LICENSED 2.
ACCORDANCE WITH THEIR LISTING.
LABELED AND LISTED AND PROVIDED IN
ALL EQUIPMENT AND MATERIAL WILL BE 1.
CONTRACTOR'S COSTS.
UTILITY (DUKE) TO BE INCORPORATED INTO THE
ANY COSTS ACCRUED BY THE WORK WITH THE 32.
UTILITY.
AND COORDINATE FINAL RESPONSIBILITIES WITH
SEE "DIVISION OF RESPONSIBILITY" MATRIX BELOW 31.
PAD MOUNTED TRANSFORMER.
CONDUITS FROM THE UTILITY POLE TO THE 750 KVA
UTILITY TO PLAN AND INSTALL THE CABLES AND
THE CONTRACTOR SHALL COORDINATE WITH THE 30.
EQUIVALENT TO THE ORIGINAL.
THE GROUNDING SYSTEM WITH MATERIALS
WITH THE PROJECT, THE CONTRACTOR SHALL REPAIR
SYSTEM IS COMPROMISED BY THE WORK ASSOCIATED
IN ANY LOCATIONS THAT THE EXISTING GROUNDING 29.
SITE.
SHALL BE DISPOSED OF BY THE CONTRACTOR OFF
EXISTING EQUIPMENT SLATED TO BE REPLACED 28.
AND MATERIALS PROVIDED TO THE OWNER.
ALL MANUFACTURER'S WARRANTIES FOR EQUIPMENT
THE CONTRACTOR SHALL TURN OVER TO THE OWNER 27.
PLANS SHALL BE SUBMITTED TO USACE FOR REVIEW.
SHALL BE DEVELOPED WITH THE PROJECT STAFF. THE
SERVICE INTERRUPTION PLAN IF NEEDED. THE PLAN
RESPONSIBLE FOR PROVIDING AN ELECTRICAL
BY SITE PERSONNEL. THE CONTRACTOR IS
CONSTANT ACCESS TO THE BUILDING AS REQUIRED
CONSTRUCTION. CONTRACTOR TO ACCOMMODATE
OPERATIONAL DURING ENTIRE PERIOD OF
ALL PUMP STATION SYSTEMS SHALL REMAIN FULLY 26.
TRANSFORMER
TRANSFORMER PAD
TRANSFORMER PRIMARY TERMINATIONS
TRANSFORMER SECONDARY TERMINATIONS
PRIMARY UTILITY POLE/METERING ON XFMR
PRIMARY DUCT BANK
SECONDARY DUCT BANK
PRIMARY CONDUCTORS
SECONDARY CONDUCTORS
ITEM
FURNISH FURNISHINSTALL INSTALL
DUKE ENERGYCONTRACTOR
DIVISION OF RESPONSIBILITY
X X
XX
X X
XX
XX
X X
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:52:46 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_ES101.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg12:52:46 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_ES101.dgn
ES101
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
E L E
C T
R
IC
A L S
IT
E P
L A
N
GENERAL SHEET NOTES
A1
ELECTRICAL SITE PLAN
1/16" = 1'0" 0 8' 16' 32'
SHEET KEYNOTES
E L E
C T
R
IC
A L S
IT
E P
L A
N
CERTIFIED FINAL DOCUMENTS - RTA
E
S .d g n
B R
IA
N P
O R
T E
R P
E
SPELLS, AND SHALL NOT LEACH OUT OVER TIME.
PERFORM IN ALL SOIL CONDITIONS, EVEN DURING DRY
COMPRESSIVE STRENGTH OF 100-200 PSI. IT SHALL
HAVE A FLEXURAL STRENGTH OF 300-450 PSI AND A
RESISTIVITY OF LESS THAN 20 OHMS. MATERIAL SHALL
FULLY CURE WITHIN 28 DAYS AND SHALL HAVE A
GROUND ENHANCING MATERIAL (GEM). MATERIAL SHALL
BURIED HORIZONTALLY AND BACKFILLED WITH A
THAN 36" BELOW GRADE. ALL GROUND RODS SHALL BE
SERVICE DISCONNECT SHALL BE BURIED NO DEEPER
SERVICE GROUNDING ROD ROUTED FROM EXISTING 5.
RETURNED TO ORIGINAL CONDITION.
PAVING DETAILS. CONCRETE GUTTER SHALL BE
PARKING LOT SHALL BE REPAVED. SEE CS501 FOR
UPON COMPLETION OF INSTALLATION OF DUCT BANKS, 4.
CONTINUOUS ACCESS TO BUILDING AS REQUIRED.
COORDINATE WITH FACILITY FOR MAINTAING 3.
GUARD RAIL OR EXISTING SLAB ON GRADE.
CONDUCTOR DETAIL. ROUTE AS NECESSARY TO AVOID
BANK DETAILS, AS WELL AS GROUNDING ELECTRODE
SEE SHEET E-501 FOR PRIMARY AND SECONDARY DUCT 2.
AREAS/DIRECTION.
SHEETS CG101 FOR EARTHWORK FOR FINAL IMPACTED
REQUIRE EARTHWORK TO BRING TO GRADE. SEE
LOCATION OF 750 kVA PAD MOUNT TRANSFORMER TO 1.
C O
N T
R A
C T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
PAD/SERVICE
LOCATION OF EXISTING SUBSTATION EQUIPMENT 11.
BANK/GROUNDING ELECTRODE CONDUCTOR
BELOW GRADE CONCRETE ENCASED DUCT 10.
EXISTING BELOW GRADE GENERATOR WIRING9.
GROUNDING ELECTRODE FOR SERVICE GROUND8.
EXISTING 1200A FUSED SERVICE DISCONNECT7.
EXISTING SERVICE DISCONNECT)
(REQUIRES EXCAVATION THROUGH PARKING LOT TO
CONCRETE ENCASED SECONDARY DUCT BANK 6.
AREA REQUIRING EARTHWORK TO BRING TO GRADE5.
SOLIDY GROUNDED SECONDARY
750 kVA PAD MOUNT TRANSFORMER WIRED DELTA WYE - 4.
BOLLARDS3.
DUCT BANK
30' MINIMUM (BY UTILITY). PRIMARY CONCRETE ENCASED
AERIAL FEED TO PRIMARY UTILITY POLE AT HEIGHT OF 2.
EXISTING DUKE UTILITY POLE1.
2 2 2
6 6 6
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:53:06 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_ED101.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
ED101
L
A W
R E
N C
E
M L
A W
R E
N C
E
D1
EXISTING SUBSTATION PLAN
SCALE: 3/8" = 1' 4'0 2' 8'
NORTH
L
A W
R E
N C
E
SHEET KEYNOTES
E L E
C T
R
IC
A L D
E M
O L
IT
IO
N P
L A
N
5 5
EXISTING CONCRETE PAD8.
EXISTING SECONDARY CONDUIT SYSTEM7.
EXISTING PRIMARY UTILITY FEED6.
EXISTING SUBSTATION STRUCTURE5.
EXISTING SECONDARY WIRING4.
EXISTING SECONDARY BUSWAY3.
EXISTING PRIMARY HORN GAP SWITCH2.
EXISTING TRANSFORMER1.
SUBSTATION EQUIPMENT MOUNTING TO REMAIN.
EXISTING CONCRETE PAD CURRENTLY USED FOR 6.
AND INTO TOP OF EXISTING DISCONNECT.
PARKING LOT TO SOUTH WALL OF STATION, UP WALL,
SHALL BE ROUTED BELOW GRADE THROUGH THE
REPLACEMENT TRANSFORMER SECONDARY DUCT BANK
WALL OF THE PUMP STATION SHALL BE REMOVED.
FROM EXISTING STRUCTURE ROUTED TO THE SOUTH
THE EXISTING SECONDARY CABLES AND CONDUITS 5.
TRANSFORMER LOCATION.
SHALL BE REMOVED. SEE SITE PLAN FOR REPLACEMENT
TRANSFORMERS IN A DELTA-DELTA CONFIGURATION
THE EXISTING THREE 250KVA SINGLE PHASE 4.
WORK.
GOVERNMENT PROJECT OFFICE PRIOR TO DEMOLITION
BETWEEN THE CONTRACTOR, THE UTILITY, AND THE
COORDINATION FOR DE-ENERGIZING MUST OCCUR 3.
480 VOLT SERVICE METERING WITH UTILITY.
THE SUBSTATION. COORDINATE REMOVAL OF EXISTING
EXISTING EQUIPMENT LOCATIONS WITH RESPECT TO
SEE REFERENCE PHOTOS ON SHEET ED501 FOR 2.
MATERIALS OFF SITE.
RESPONSIBLE FOR DISPOSING OF THE DEMOLISHED
SHALL BE DEMOLISHED. THE CONTRACTOR IS
THE PROJECT'S EXISTING TRANSFORMER SYSTEM
METERING AND ANY OTHER ITEMS ASSOCIATED WITH
THE STRUCTURE, TRANSFORMERS, CONDUIT, CABLES, 1.
GENERAL SHEET NOTES
E L E
C T
R
IC
A L D
E M
O L
IT
IO
N P
L A
N
E
D .d g n
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:53:25 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_ED501.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
ED501
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
GENERAL SHEET NOTES
A1
SCALE: NTS
SHEET KEYNOTES
E1
SCALE: NTS
EXISTING PUMP STATION SUBSTATION PAD EQUIPMENT
EXISTING PUMP STATION SUBSTATION PAD EQUIPMENT
A1
SCALE: NTS
EXISTING PUMP STATION SUBSTATION PAD EQUIPMENT/UTILTY FEED
P U
M P S
T A
T
IO
N S
U B
S T
A T
IO
N
E Q
U
IP
M E
N T D
E M
O L
IT
IO
N P
H O
T O
S
EXISTING TRANSFORMER MOUNTING STRUCTURE12.
EXISTING SUBSTATION STRUCTURE11.
EXISTING UTILITY POLE10.
EXISITNG 240/120 LIGHTING TRANSFORMER9.
EXISTING 240/120 AERAL SERVICE FEED8.
EXISTING PRIMARY CONDUCTORS7.
EXISTING HORN GAP GANG OPERATED SWITCH6.
EXISTING AERAL SERVICE FEED5.
EXISTING SECONDARY WIRING4.
EXISTING SERVICE TRANSFORMERS3.
CONNECTION
EXISTING SECONDARY BUSBAR FOR TRANSFORMER 2.
EXISTING SECONDARY RACEWAY1.
E Q
U
IP
M E
N T D
E M
O L
IT
IO
N P
H O
T O
S
P U
M P S
T A
T
IO
N S
U B
S T
A T
IO
N
E
D .d g n
ALL EXISTING FENCING SHALL BE REMOVED. 3.
TRANSFORMER, AND UTILITY POLE) SHALL BE REMOVED.
(ASIDE FROM 240/120 AERAL FEED, 240/120 LIGHTING
ALL EQUIPMENT CALLED OUT IN SHEET KEYNOTES 2.
DEMOLITION.
SEE SHEET ED101 FOR PLAN VIEW OF SUBSTATION 1.
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
M
IN
3" 2" 3"
3" 2" 3"2"
'0
M
IN
2"
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:53:48 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E501.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
FROM MAT.
RING. PLACE 36" MINIMUM
#2 AWG MINIMUM GROUND
PAD ON ALL SIDES
A MINIMUM OF 12" BEYOND
GRAVEL FILL. EXTEND
UNIT ON ALL SIDES
A MINIMUM OF 6" BEYOND
CONCRETE PAD. EXTEND
SECONDARY CONDUITS
GROUND AND CABLE SHIELDS
SURGE ARRESTERS, ENCLOSURE
GROUNDING CONDUCTORS FOR
#2 AWG MINIMUM
GROUND ROD (TYP)
SECTION
TRANSFORMER
CONDUITS
PRIMARY
ELEVATION
PRIMARY VOLTAGE SECTION
GRAVEL FILL
WIRE MESH
6 X 6 - W2.9 X W2.9
REINFORCED WITH
8" CONCRETE PAD
SECTION
VOLTAGE
SECONDARY
DUCT BANK TO PUMP STATION
DISCONNECT
SERVICE
SUPPORT FOR
ALUMINUM
FABRICATED
DISCONNECT
SERVICE
CAST IN PLACE CONCRETE PAD
INSTALLED BY UTILITY CO.
FURNISHED AND
TYPE TRANSFORMER
COMPARTMENTAL
PAD MOUNTED
W/UTILITY CO. REQUIREMENTS.
AND INSTALLED BY CONTRACTOR, IAW
PRECAST CONCRETE PIT PAD FURNISHED
INSTALLATION DETAILS.
ORIENTATION AND
W/UTILITY CO. FOR
CONTRACTOR. COORDINATE
AND INSTALLED BY
PRECAST "PIT PAD" FURNISHED
18" BELOW GRADE (TYP)
ROD
CLAD STEEL GROUND
3/4" X 10' LONG COPPER-
ANSI C2.
20' PER
MUST BE SEPARATED BY
GROUNDING
NEUTRAL GROUNDING.
SECONDARY
#2 AWG (INSULATED)
STATION
PUMP
TO
BANK
DUCT
FINISH GRADE
ENCASEMENT
CONCRETE
C C
95%. ASTM 1556
RE-COMPACT SUBGRADE TO
WITH METAL TRACER
RED WARNING TAPE
C CC
MARKING TAPE
4" CONDUIT (TPY.)
ENCASEMENT
CONCRETE
DUCT BANK - SEE CIVIL DRAWINGS
RESTORE PAVEMENT OVER SECONDARY
TO 95%. ASTM 1556
RE-COMPACT SUBGRADE
E-501
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
A1
TRANSFORMER PAD PLAN AND ELEVATION
SCALE: NTS
E5
A6
PRIMARY VOLTAGE DUCT BANK DETAIL
GENERAL SHEET NOTES
SECONDARY DUCT BANK DETAIL
T R
A N
S F
O R
M E
R P
A D A
N D D
U C
T B
A N
K D
E T
A
IL
S
FLAT.
GRAVEL FILL AROUND THE TRANSFORMER PAD IS TO BE 4.
DIAGRAM FOR REQUIRED WIRING - SHEET E-602.
SEE UPDATED POWER DISTRIBUTUION ONE LINE 3.
EXISITNG GENERATOR DUCT BANK EXAMPLE.
DISCHARGE PIPING. SEE PHOTOS ON SHEET E-502 FOR
SECONDARY DUCT BANK TO PASS BENEATH EXISTING 2.
GOVERNMENT PROJECT OFFICE.
BETWEEN THE CONTRACTOR, THE UTILITY, AND THE
COORDINATION FOR DE-ENERGIZING MUST OCCUR 1.
T R
A N
S F
O R
M E
R P
A D A
N D D
U C
T B
A N
K D
E T
A
IL
S
E .d g n
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:54:05 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E502.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
E-502
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
D1
SCALE: NTS
A1
A5
A7
GENERAL SHEET NOTES
EXISTING GENERATOR DUCT BANK CONSTRUCTION PHOTO GENERATOR DUCT BANK GENERATOR DUCT BANK
EXISTING DISCHARGE PIPING PLAN
D
IS
C H
A R
G E P
IP
IN
G /G
E N
E R
A T
O R D
U C
T B
A N
K P
H O
T O
S
BEEN PROVIDED FOR REFERENCE.
EXISTING GENERATOR BELOW GRADE DUCT BANK HAVE
EQUIPMENT LOCATIONS. INSTALLATION PHOTOS OF THE
FOR STATION SOUTH WALL ELEVATION WITH EXISTING
FUSED 1200A DISCONNECT SWITCH. SEE SHEET E-503
BENEATH EXISTING PIPING AND ROUTE TO EXISTING
DISCHARGE PIPING. DUCT BANK SHALL TRAVERSE
COORDINATE SECONDARY DUCT BANK WITH EXISTING 1.
D
IS
C H
A R
G E P
IP
IN
G /G
E N
E R
A T
O R D
U C
T B
A N
K P
H O
T O
S B
R
IA
N P
O R
T E
R P
E
E .d g n
C O
N T
R A
C T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:54:34 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E503.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
E-503
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
GENERAL SHEET NOTES
D1
SCALE: NTS
EXISTING EQUIPMENT ON PUMP STATION SOUTH WALL
A1
SCALE: NTS
A1
SCALE: NTS
EXISTING GENERATOR DISCONNECT SWITCH "DS-EM" INTERIOR EXISTING SERVICE DISCONNECT SWITCH "DS-ETR" INTERIOR
SHEET KEYNOTES
P U
M P S
T A
T
IO
N S
O U
T H W
A L L E
X
IS
T
IN
G E
Q U
IP
M E
N T
P U
M P S
T A
T
IO
N S
O U
T H W
A L L E
X
IS
T
IN
G E
Q U
IP
M E
N T
E .d g n
UTILITY.
COORDINATE 480 VAC METERING REMOVAL WITH 4.
SERVICE FEEDERS TO THE PUMP STATION.
BOX, CONNECTING NEW SERVICE FEEDERS TO EXISTING
DISC. SW. WHICH WILL NOW BE USED AS A JUNCTION
TO ENTER BOTTOM OF EXIST. SERVICE TRANSITION UP
ROUTED TO SOUTH WALL OF PUMP STATION,
BELOW GRADE SECONDARY DUCT BANK CONDUIT TO BE 3.
ED101 AND ED501 FOR MORE INFORMATION.
REMOVAL OF SUBSTATION EQUIPMENT - SEE SHEET 2.
ELECTRICAL EQUIPMENT
SEE SHEET E601 FOR SIZING OF PERTINENT EXISTING 1.
PORTABLE GENERATOR - TO REMAIN
EXISTING ENCLOSURE BOX "B-1" FOR CONNECTIVITY TO 9.
REMAIN
EXISTING 240 VAC SERVICE WIRING/RACEWAY - TO 8.
EXISTING 240 VAC SERVICE METERING - TO REMAIN7.
SWITCH- TO REMAIN
CONDUCTORS TO EXISTING MANUAL TRANSFER
EXISTING CONDUIT RACEWAY FOR GENERATOR 6.
TO REMAIN
GENERATOR ISOLATION DISCONNECT SWTICH "DS-EM" - 5.
EXISTING 480 VAC SERVICE METERING - TO BE REMOVED4.
OUTGOING.
ACCOMMODATE NEW CONDUCTORS, INCOMING AND
REMAIN. ADD NEUTRAL AND GROUND BUS BARS TO
EXISTING SERVICE DISC. SW. TO W/1000A FUSING
EXISTING SERVICE DISCONNECT SWITCH - 1200A FRAME 3.
REMOVED
EXISTING SECONDARY CONDUIT RACEWAY - TO BE 2.
REMOVED
FROM EXISTING SUBSTATION TRANSFORMERS - TO BE
EXISTING SECONDARY WEATHERHEADS - POWER FEED 1.
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:54:57 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E601.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
E601
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
SHEET KEYNOTES
A1
EXISTING POWER DISTRIBUTION ONE LINE DIAGRAM
SCALE: NTS
L1
L2
L3
G
E X
IS
T
IN
G P
H A
S E /G
R O
U N
D
IN
N D
U C
T O
R S T
O M
O T
N T
R O
L C
E N
T E
R
EXISTING TRANSER SWITCH
EXISTING EMERGENCY
GENERATOR
G1
G2
G3
U1
U2
U3
EXISTING GROUNDING TO
MOTOR MOUNTING PLATE
BOX B-1
ENCLOSURE
EXISTING
EB1
EB2
EB3
E X
IS
T
IN
G P
O W
E R D
IS
T R
IB
U T
IO
N O
N E L
IN
E D
IA
G R
A M
"DS-EM"
DISCONNECT SWITCH
EXISTING GENERATOR
"DS-ETR"
GENERAL SHEET NOTES
FURTHER DIRECTION.
ELECTRICAL DEMOLITION SHEETS ED101 AND ED501 FOR
SERVICE SECONDARY TO BE DEMOLISHED. SEE
EXISTING SERVICE PRIMARY, SERVICE TRANSFORMER, 4.
EMERGENCY SIDE OF MANUAL TRANSFER SWITCH.
DISCONNECT SWTICH. SHARED LUGS ARE LOCATED ON
WIRING DOWNSTREAM OF EMERGENCY GENERATOR
WIRING DOWNSTREAM OF BOX "B-1" SHARES LUGS WITH 3.
VERIFY EXISTING CONDTIONS IN THE FIELD.
DIAGRAM FOR REFERENCE ONLY. CONTRACTOR TO 2.
SYSTEM.
SHEET E602 FOR UPDATES TO POWER DISTRIBUTION
ONE LINE DIAGRAM SHOWS EXISTING CONDITIONS. SEE 1.
E X
IS
T
IN
G P
O W
E R D
IS
T R
IB
U T
IO
N O
N E L
IN
E D
IA
G R
A M
E .d g
F1
EXISTING GENERATOR OUTPUT CIRCUIT BREAKER
SWITCH.
GENERATOR TERMINALS THE NEW, MANUAL TRANSFER
GENSET NEUTRAL SHALL BE EXTENDED FROM THE
PROTECTION BECAUSE OF THE NEW SERVICE TYPE.
GENSET OUTPUT CB TO ONE WITH GROUND FAULT
NOTE THE LIMITED SPACE FOR CONVERTING THE EXIST. 11.
EXISTING 3 SETS OF 3-600 KCMIL10.
EXISTING 3/0 GROUND9.
EXISTING GROUNDING BUS8.
EXISTING NEUTRAL BUS7.
NOT USED6.
EXISTING 6 AWG5.
EXISTING 3 SETS OF 1-4/0 GROUND4.
EXISTING 3 SETS OF 3-4/0 WELDING CABLE3.
EXISTING 3 SETS OF 1-3/0 GROUND2.
EXISTING 3 SETS OF 3-500 KCMIL1.
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
10 10
6 13
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:55:11 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_E602.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
E-602
L
A W
R E
N C
E
M L
A W
R E
N
L
A W
R E
N C
E
G
C O
N T
R O
L C
E N
T E
R C
O N
D U
C T
O R
S T
O M
O T
X
IS
T
IN
G P
H A
S E /G
R O
U N
D
IN
GENERATOR
EXISTING EMERGENCY
G1
G2
G3
EB1
EB2
EB3
L1
L2
L3
MOTOR MOUNTING PLATES
EXISTING BONDING TO
A1
UPDATED POWER DISTRIBUTION ONE LINE DIAGRAM
SCALE: NTS
SHEET KEYNOTESGENERAL SHEET NOTES
CONECTION BOX "B-1"
LOAD BANK
N
G
U P
D A
T E
D P
O W
E R D
IS
T R
IB
U T
IO
N O
N E L
IN
E D
IA
G R
A M
"DS-EM"
DISCONNECT SWITCH
EXISTING GENERATOR
U P
D A
T E
D P
O W
E R D
IS
T R
IB
U T
IO
N O
N E L
IN
E D
IA
G R
A M
E .d g n
UTILITY LINE
3PHASE, 60HZ
7200/12470V, INCOMING
CONDUIT
BANK W/ 4-4" PVC
ENCASED DUCT
CONCRETE
AWG GND
NEUTRAL, 1#3/0
1#500KCMIL
3 SETS 3#500kcmil, 4-4" PVC CONDUIT
POSSIBLE.
5%IMPEDANCE IF
UTILITY CO. PREFER
PROVIDED BY ELEC.
GROUNDED.
480/277 SOLIDLY
XFMR, 7200/12470 -
NOMINAL 750KVA
OVERLAPPING NEUTRAL.
BE 4 POLE, NON
RESPECTS, EXCEPT SHALL
EXIST. SWITCH IN ALL
SHALL MEET SPEC OF
SYSTEM. NEW SWITCH
THE SEPARATELY DERIVED
SWITCH THE NEUTRAL FOR
SWITCH IN ORDER TO
REPLACE W/4 POLE
REMOVE AND 6" MAX.
HEIGHT ABOVE EXIST. SW,
IS 39.5", MAX. ADD'L
FOR NEW TRANSFER SW.
6293586. AVAILABLE WIDTH
FACTORY ORDER NUMBER
3 POLE, 1200A, SQUARE D
EXIST. TRANSFER SWITCH.
THICK MIN., 2"X3".
OUTDOOR ACRYLIC, 1/16"
BRONZE, BRASS OR
FABRICATE LABEL FROM
SERVICE FEEDERS".
"DISCONNECT FOR BLDG.
ENCL. ENSCRIBED TO READ
ATTACH LABEL TO DOOR OF
AND GROUND CONDUCTORS.
FOR ADDITION OF NEUTRAL
TO REMAIN AS IS, EXCEPT
EXIST. FUSED DISCONNECT
PRIMARY VOLTAGE WIRING.
ELECT. UTILITY CO. WILL PULL IN AND CONNECT ALL 7.
EXISTING EQUIPMENT.
BUILDING ADDITION FOR LOCATION AND ROUTING OF
SEE DRAWING APPENDIX I - EMERGENCY GENERATOR 6.
APPROXIMATELY 50'.
NEUTRAL CONDUCTOR. CONDUIT RUN IS
BE UPGRADED TO 4" TO ACCOMMODATE ADDITIONAL
GOING TO TRANSFER SWITCH ARE 3" AND WILL NEED TO
FROM BOX "B-1" PENETRATING INTO STATION AND
PROJECT. ADDITIONALLY, EXISTING EMT CONDUIT RUNS
COORDINATE MALE/FEMALE PLUG REQUIREMENTS WITH
COMPATIBLE WITH EXISTING CONNECTIONS.
ARE LEVITON 13D26-U. NEW CONNECTIONS SHALL BE
BANK/PORTABLE GENERATOR. EXISTING CONNECTIONS
PLUG RECEPTACLES FOR CONNECTION TO LOAD
NEUTRAL CONNECTIONS ADDED TO BOX "B-1" REQUIRE 5.
PHASE CONDUCTOR SET.
PROVIDED, RUN EACH CONDUCTOR WITH EXISTING
WHERE MULTIPLE SETS OF NEUTRAL CONDUCTORS ARE 4.
CONDUCTOR SET.
ARE PROVIDED , RUN EACH SET WITH PHASE
WHERE MULTIPLE SETS OF GROUNDING CONDUCTORS 3.
CABLES PRESENT SHALL NOT BE ALLOWED.
NEUTRAL CONDUCTORS IN CONDUITS WITH EXISTING
CONDUCTOR AS ONE CIRCUIT PULL. INSTALLING
REMOVED AND REINSTALLED WITH THE NEUTRAL
OF GROUNDING WIRING. EXISTING RUNS SHALL BE
WITH LARGER LUG TO ACCOMMODATE MULTIPLE SETS
LUG IN EXISTING 1200A SERVICE DISCONNECT SWITCH
CONDUCTOR ACCOMMODATION. REPLACE GROUNDING
ENCLOSURE WITH NEUTRAL BUS FOR NEUTRAL
PROVIDE EXISTING 1200A SERVICE DISCONNECT 2.
ONE LINE DIAGRAM.
SEE SHEET E601 FOR EXISTING POWER DISTRIBUTION 1.
B R
IA
N P
O R
T E
R P
E C
O N
T R
A C
T N
U M
B
O J E
C T I
D
F
IL
E N
A M
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E /2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
W P -2
-B
EQUIPMENT WITH THE ELECTRIC UTILITY COMPANY.
INSTALLATION OF PAD, CONDUITS AND METERING
CORDS IN CONDUITS. CONTRACTOR SHALL COORDINATE
"PIT PAD", CONDUITS, ALL SECONDARY WIRING, AND PULL
INSTALL ALL OTHER ITEMS INCLUDING, BUT NOT LIMITED TO,
UTILITY COMPANY. CONTRACTOR SHALL FURNISH AND
CABLES SHALL BE FURNISHED AND INSTALLED BY ELECTRIC
COMMERCIAL POWER SERVICE XFMR AND 12KV POWER 20.
APPROVAL.
PROTECTION, LSIG. SUBMIT DETAILS OF REPLACEMENT FOR
REPLACED WITH A 1200A CKT. BKR. WITH GROUND FAULT
EXIST. 1200 A GENSET OUTPUT CKT. BKR. SHALL BE 19.
DISCONNECT WITH TRANSFORMER FLA AND IMPEDANCE.
COORDINATE AIC RATING OF SERVICE STRUCTURE.
4X ENCLOSURE. SUPPORTED BY FABRICATED ALUMINUM
PROTECTION. (LSIG). RATED FOR 25 KAIC MINIMUM, IN NEMA
TIME, SHORT TIME, INSTANTANEOUS AND GROUND FAULT
1000A, 3P, 480 VAC. ENCLOSED CIRCUIT BREAKER, W/LONG 18.
INSTALLATION REQUIREMENTS.
COORDINATE W/ELECT. UTILITY CO. FOR ADDITIONAL
PAD WILL BE FURNISHED AND INSTALLED BY CONTRACTOR.
WITH PULL ROPE AND SWEEPING ELBOW AT TRANSFORMER
BY ELECT. UTILITY CO. 1 4" CONDUITS BURIED 36'' DEEP
PRIMARY PHASE CONDUCTORS, FURNISHED AND INSTALLED 17.
PHASE CONDUCTORS - 3 SETS OF 3-500 KCMIL16.
GROUNDING BUS/LUG15.
PER EACH SET OF PHASE CONDUCTORS)
SYSTEM GROUNDING CONDUCTOR - 3 SETS OF 1-1/0 AWG (1 14.
MAIN BONDING JUMPER - 1-4/0 AWG13.
PER EACH SET OF PHASE CONDUCTORS)
NEW NEUTRAL CONDUCTORS - 3 SETS OF 1-500 KCMIL (1 12.
EXISTING PHASE CONDUCTORS - 3 SETS OF 3-500 KCMIL11.
WITH EACH SET OF PHASE CONDUCTORS)
NEW NEUTRAL CONDUCTORS - 3 SETS OF 1-600 KCMIL (RUN 10.
NEUTRAL BUS/LUG9.
EXISTING GROUNDING BUS8.
EXISTING NEUTRAL BUS7.
CONDUCTOR - 3/0 AWG
SERVICE DISCONNECT GROUNDING ELECTRODE 6.
CONDUCTORS - 6 AWG
EXISTING GENERATOR GROUNDING ELECTRODE 5.
AWG GROUND
EXISTING "B-1" GROUNDING CONDUCTORS - 3 SETS OF 1-4/0 4.
WELDING CABLE
EXISTING "B-1" PHASE CONDUCTORS - 3 SETS OF 3-4/0 AWG 3.
GROUND
EXISTING SYSTEM BONDING JUMPER - 3 SETS OF 1-3/0 AWG 2.
3-600 KCMIL
EXISTING GENERATOR/B1 PHASE CONDUCTORS -3 SETS OF 1.
8'-2"
3'-0"
EDGE OF GRAVEL FILL
TRANSFORMER
SUPPORT STRUCTURE
SWITCH AND
SERVICE DISCONNECT
W
IT
H C
O N
C R
E T
E P
A D
C E
N T
E R E
Q U
IP
M E
N T
3'0" 6'-0"
5'-10"
1'-2"
COORDINATE DETAILS WITH ELECT. UTILITY CO.
PRE CAST "PIT PAD" FURNISHED AND INSTALLED BY CONTRACTOR.
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
12:55:25 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_S-501.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
2" CLEAR COVER, TYP
FINAL GRADE
ALL SIDES, TYP.
1/2" CHAMFER
MIN. 9" GRAVEL FILL
TYP.
REINFORCED WIRE MESH
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
N T
R A
C T N
U M
B
12:55:25 PM 5/20/2021
...\Markle Transformer Replacement-488338-TBD\40 - Geospatial Data\Drawings\CAD_BIM\_Sheets\128619_S-501.dgn
PD: AEC_pdf.pltcfg DS: AEC_Screen.dscript
F A
Y E L
E F F
L E
R P
E
C O
N C
R E
T E P
A D D
E T
A
IL
S
M A
R K
L E T
R A
N S
F O
R M
E R R
E P
L A
C E
M E
N T
S-501
Z A
Z A
H R
A A A
L K
H A
F A J I
/2
F A
Y E L
E F F
L E
R P
E
C O
N C
R E
T E P
A D D
E T
A
IL
S
M A
R K
L E T
R A
N S
F O
R M
E R R
E P
L A
C E
M E
N T
S-501
Z A
Z A
H R
A A A
L K
H A
F A J I
/2
C H
IC
A G
O
IL
L
IN
O
IS
S L
A S
A L L E S
T S
U
IT
E
C H
IC
A G
O D
IS
T R
IC
T
F A
Y E L
E F F
L E
R P
E
C O
N C
R E
T E P
A D D
E T
A
IL
S
M A
R K
L E T
R A
N S
F O
R M
E R R
E P
L A
C E
M E
N T
S-501
Z A
Z A
H R
A A A
L K
H A
F A J I
A6
SCALE: 1" = 1'
0 1' 2'6"
R K
L E T
R A
N S
F O
R M
E R R
E H
A B
H U
N T
IN
G T
O N
IN
J E
D W
A R
D R
O U
C H L
A K
E
S -5
.d g n
GENERAL NOTES
C1
SCALE: 3/4" = 1' 2'0 1' 4'
TRANSFORMER AND SDS PAD PLAN VIEW
SDS PAD DETAIL
AND MANUFACTURER FOR FOUNDATION/INSTALLATION REQUIREMENTS
CONSTRUCTION CONSTRUCTOR'S COORDINATION WITH UTILITY COMPANY
INSTALLMENT OF A LARGE TWO-PIECE PRE-CAST PIT PAD REQUIRES THE 6.
SYSTEM.
OF THE CONCRETE PAD. USE MANUFACTURER'S RECOMMENDED SUPPORT
INSTALL SDS SUCH THAT THE BOTTOM OF THE CASING IS 24" ABOVE THE TOP 5.
UTILITY COMPANY OR TRANSFORMER MANUFACTURER.
PLACE TRANSFORMER PAD AS SHOWN OR AS RECOMMENDED BY THE 4.
DIMENSIONS OF PAD WORK WITH THE EQUIPMENT PROVIDED.
3. CONTRACTOR SHALL MAKE ANY ADJUSTMENTS REQUIRED TO MAKE SURE
USER AS REQUIRED IN SPECIFICATION SECTION 03 30 53.
REPRESENTATIVE ON SITE WITH ELECTRICAL UTILITY CO. AND WITH THE END
2. CONDUIT PLACEMENT SHALL BE COORDINATED WITH THE GOVERNMENT
CONCRETE PAD IN ALL DIRECTIONS.
GRAVEL FILL SHALL EXTEND AT LEAST 3 FEET FROM THE EDGE OF THE 1.
WINDOW
J E
R E
M Y H
A R
R
IS
J E
R E
M Y H
A R
R
IS
J E
R E
M Y H
A R
R
IS
W P -2
-B
A6
S-501
A6
S-501
| 001-Markle RTA Plans |
| 002-Markle RTA Plans |
| 003-Markle RTA Plans |
| 004-Markle RTA Plans |
| 005-Markle RTA Plans |
| 006-Markle RTA Plans |
| 007-Markle RTA Plans |
| 008-Markle RTA Plans |
| 009-Markle RTA Plans |
| 010-Markle RTA Plans |
| 011-Markle RTA Plans |
| 012-Markle RTA Plans |
| 013-Markle RTA Plans |
| 014-Markle RTA Plans |
| 015-Markle RTA Plans |