I HC CDF Ent r ance Road Resur f aci ng W912P618B0008
SECTI ON TABLE OF CONTENTS
DI VI SI ON 01 - GENERAL REQUI REMENTS
SECTI ON 01 11 00
SUMMARY OF WORK
05/15
PART 1 GENERAL
1. 1 WORK COVERED BY CONTRACT DOCUMENTS
1. 1. 1 Pr oj ect Descr i pt i on
1. 1. 2 Locat i on
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON ( NOT USED)
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 01 11 00 Page 1
AMD - 0001
SECTI ON 01 11 00
SUMMARY OF WORK
05/15
PART 1 GENERAL
1. 1 WORK COVERED BY CONTRACT DOCUMENTS
1. 1. 1 Pr oj ect Descr i pt i on
Cont r act or wi l l r esur f ace 1, 128 l i near f eet ( LF) of an exi st i ng 24- f oot wi de gr avel pavement of t he ent r ance r oad l ocat ed bet ween t he sout h, mai n ent r ance and admi ni st r at i ve bui l di ngs pr esent at t he I ndi ana Har bor and Canal Conf i ned Di sposal Faci l i t y . Cont r act or wi l l excavat e t he exi st i ng ent r ance r oad' s aggr egat e/ s l ag and subsoi l as shown on t he dr awi ngs and deposi t t he excavat ed mat er i al al ong er oded ar eas of t he conf i ned di sposal f aci l i t y ' s di kes. Fi nal l ocat i ons of wher e t he spoi l ed aggr egat e / s l ag / subsoi l shal l be as di r ect ed by t he Gover nment . Cont r act or wi l l di spose of geot ext i l e r emoved f r om beneat h t he exi st i ng r oad at an appr oved of f - s i t e f aci l i t y i n accor dance wi t h Sect i on 01 57 20. 02 03 ENVI RONMENTAL PROTECTI ON FOR I NDI ANA. The Cont r act or wi l l t i e- i nt o exi st i ng concr et e pavement s at each end of t he new pavement . The wor k al so i ncl udes appl y i ng t opsoi l and seeding backf i l l i ng t he r emoved soi l al ong bot h s i des of t he pavement wi t h CA53 st one and compact i ng per Sect i on 31 23 00. 00 20 EXCAVATI ON AND FI LL.
The Cont r act or i s aut hor i zed t o mobi l i ze and execut e t he Wor k onl y af t er a Not i ce t o Pr oceed ( NTP) has been r ecei ved f r om USACE.
1. 1. 2 Location
The wor k i s l ocat ed at t he I ndi ana Har bor and Canal Conf i ned Di sposal Faci l i t y ( I HC CDF) . The exact l ocat i on of t he wor k wi l l be shown by t he Cont r act i ng Of f i cer ' s Repr esent at i ve.
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON ( NOT USED)
- - End of Sect i on - -
SECTI ON 01 11 00 Page 2
DI VI SI ON 01 - GENERAL REQUI REMENTS
SECTI ON 01 35 26
GOVERNMENTAL SAFETY REQUI REMENTS
11/14
PART 1 GENERAL
1. 1 REFERENCES
1. 2 DEFI NI TI ONS
1. 3 SUBMI TTALS
1. 4 REGULATORY REQUI REMENTS
1. 5 SI TE QUALI FI CATI ONS, DUTI ES AND MEETI NGS
1. 5. 1 Per sonnel Qual i f i cat i ons
1. 5. 1. 1 Si t e Saf et y and Heal t h Of f i cer ( SSHO)
1. 5. 1. 1. 1 Cont r act or Qual i t y Cont r ol ( QC) Per son:
1. 5. 1. 2 Cr ane Oper at or s
1. 5. 2 Per sonnel Dut i es
1. 5. 2. 1 Si t e Saf et y and Heal t h Of f i cer ( SSHO)
1. 5. 3 Meet i ngs
1. 5. 3. 1 Pr econst r uct i on Conf er ence
1. 6 ACCI DENT PREVENTI ON PLAN ( APP)
1. 6. 1 EM 385- 1- 1 Cont ent s
1. 7 ACTI VI TY HAZARD ANALYSI S ( AHA)
1. 8 DI SPLAY OF SAFETY I NFORMATI ON
1. 9 SI TE SAFETY REFERENCE MATERI ALS
1. 10 EMERGENCY MEDI CAL TREATMENT
1. 11 NOTI FI CATI ONS and REPORTS
1. 11. 1 Acci dent Not i f i cat i on
1. 11. 2 Acci dent Repor t s
1. 11. 3 Cr ane Repor t s
1. 11. 4 Cer t i f i cat e of Compl i ance
1. 12 HOT WORK
1. 13 RADI ATI ON SAFETY REQUI REMENTS
1. 14 FACI LI TY OCCUPANCY CLOSURE
1. 15 SEVERE STORM PLAN
1. 16 CONFI NED SPACE ENTRY REQUI REMENTS.
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON
3. 1 CONSTRUCTI ON AND OTHER WORK
3. 1. 1 Hazar dous Mat er i al Excl usi ons
3. 1. 2 Unf or eseen Hazar dous Mat er i al
3. 2 PRE- OUTAGE COORDI NATI ON MEETI NG
3. 3 CONTROL OF HAZARDOUS ENERGY ( LOCKOUT/ TAGOUT)
3. 4 FALL HAZARD PROTECTI ON AND PREVENTI ON PROGRAM
3. 4. 1 Tr ai ni ng
3. 4. 2 Fal l Pr ot ect i on Equi pment and Syst ems
3. 4. 2. 1 Per sonal Fal l Ar r est Equi pment
SECTI ON 01 35 26 Page 1
3. 4. 3 Fal l Pr ot ect i on f or Roof i ng Wor k
3. 4. 4 Hor i zont al Li f el i nes
3. 4. 5 Guar dr ai l s and Saf et y Net s
3. 4. 6 Rescue and Evacuat i on Pr ocedur es
3. 5 EQUI PMENT
3. 5. 1 Mat er i al Handl i ng Equi pment
3. 5. 2 Wei ght Handl i ng Equi pment
3. 5. 3 USE OF EXPLOSI VES
3. 6 EXCAVATI ONS
3. 6. 1 Ut i l i t y Locat i ons
3. 6. 2 Ut i l i t y Locat i on Ver i f i cat i on
3. 6. 3 Ut i l i t i es Wi t hi n and Under Concr et e, Bi t umi nous Asphal t , and
Ot her I mper vi ous Sur f aces
3. 7 ELECTRI CAL
3. 7. 1 3. 9. 1 Por t abl e Ext ensi on Cor ds
3. 8 WORK I N CONFI NED SPACES
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 01 35 26 Page 2
SECTI ON 01 35 26
GOVERNMENTAL SAFETY REQUI REMENTS
11/14
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN SOCI ETY OF SAFETY ENGI NEERS ( ASSE/ SAFE)
ASSE/ SAFE A10. 32 ( 2012) Fal l Pr ot ect i on
ASSE/ SAFE A10. 34 ( 2001; R 2012) Pr ot ect i on of t he Publ i c on or Adj acent t o Const r uct i on Si t es
ASSE/ SAFE Z359. 1 ( 2007) Saf et y Requi r ement s f or Per sonal Fal l Ar r est Syst ems, Subsyst ems and Components
ASME I NTERNATI ONAL ( ASME)
ASME B30. 22 ( 2010) Ar t i cul at i ng Boom Cr anes
ASME B30. 3 ( 2012) Tower Cr anes
ASME B30. 5 ( 2011) Mobi l e and Locomot i ve Cr anes
ASME B30. 8 ( 2010) Fl oat i ng Cr anes and Fl oat i ng Derricks
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 10 ( 2013) St andar d f or Por t abl e Fi r e Extinguishers
NFPA 51B ( 2014) St andar d f or Fi r e Pr event i on Dur i ng Wel di ng, Cut t i ng, and Ot her Hot Wor k
NFPA 70E ( 2012; Er r at a 2012) St andar d f or El ect r i cal Saf et y i n t he Wor kpl ace
U. S. ARMY CORPS OF ENGI NEERS ( USACE)
EM 385- 1- 1 ( 2014) Saf et y and Heal t h Requi r ement s Manual
U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)
10 CFR 20 St andar ds f or Pr ot ect i on Agai nst Radi at i on
29 CFR 1910 Occupat i onal Saf et y and Heal t h St andar ds
SECTI ON 01 35 26 Page 3
29 CFR 1910. 146 Per mi t - r equi r ed Conf i ned Spaces
29 CFR 1926 Saf et y and Heal t h Regul at i ons f or Construction
29 CFR 1926. 1400 Cr anes & Der r i cks i n Const r uct i on
29 CFR 1926. 16 Rul es of Const r uct i on
29 CFR 1926. 500 Fal l Pr ot ect i on
CPL 2. 100 ( 1995) Appl i cat i on of t he Per mi t - Requi r ed Conf i ned Spaces ( PRCS) St andar ds, 29 CFR 1910.146
1. 2 DEFINITIONS
a. Hi gh Vi s i bi l i t y Acci dent . Any mi shap whi ch may gener at e publ i c i t y or hi gh v i s i bi l i t y .
b. Medi cal Tr eat ment . Tr eat ment admi ni st er ed by a physi c i an or by r egi st er ed pr of essi onal per sonnel under t he st andi ng or der s of a physi c i an. Medi cal t r eat ment does not i ncl ude f i r st ai d t r eat ment even t hr ough pr ovi ded by a physi c i an or r egi st er ed per sonnel .
c. Recor dabl e I nj ur i es or I l l nesses. Any wor k- r el at ed i nj ur y or i l l ness t hat r esul t s i n:
( 1) Deat h, r egar dl ess of t he t i me bet ween t he i nj ur y and deat h, or t he l engt h of t he i l l ness;
( 2) Days away f r om wor k ( any t i me l ost af t er day of i nj ur y/ i l l ness onset);
( 3) Rest r i ct ed wor k;
( 4) Tr ansf er t o anot her j ob;
( 5) Medi cal t r eat ment beyond f i r s t ai d;
( 6) Loss of consci ousness; or
( 7) A s i gni f i cant i nj ur y or i l l ness di agnosed by a physi c i an or ot her l i censed heal t h car e pr of essi onal , even i f i t di d not r esul t i n ( 1) t hr ough ( 6) above.
d. " USACE" pr oper t y and equi pment speci f i ed i n USACE EM 385- 1- 1 shoul d be i nt er pr et ed as Gover nment pr oper t y and equi pment .
e. Wei ght Handl i ng Equi pment ( WHE) Acci dent . A WHE acci dent occur s when any one or mor e of t he ei ght el ement s i n t he oper at i ng envel ope f ai l s t o per f or m cor r ect l y dur i ng oper at i on, i ncl udi ng oper at i on dur i ng mai nt enance or t est i ng r esul t i ng i n per sonnel i nj ur y or deat h; mat er i al or equi pment damage; dr opped l oad; der ai l ment ; t wo- bl ocki ng; over l oad;
or col l i s i on, i ncl udi ng unpl anned cont act bet ween t he l oad, cr ane, or ot her obj ect s. A dr opped l oad, der ai l ment , t wo- bl ocki ng, over l oad and col l i s i on ar e consi der ed acci dent s even t hough no mat er i al damage or i nj ur y occur s. A component f ai l ur e ( e. g. , mot or bur nout , gear t oot h f ai l ur e, bear i ng f ai l ur e) i s not consi der ed an acci dent sol el y due t o
SECTI ON 01 35 26 Page 4 mat er i al or equi pment damage unl ess t he component f ai l ur e r esul t s i n damage t o ot her component s ( e. g. , dr opped boom, dr opped l oad, r ol l over , et c. ) . Any mi shap meet i ng t he cr i t er i a descr i bed above shal l be submi t t ed wi t hi n f i ve ( 5) days.
1. 3 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:
SD- 01 Pr econst r uct i on Submi t t al s
Acci dent Pr event i on Pl an ( APP) ; G, CS
Act i v i t y Hazar d Anal ysi s ( AHA) ; G, CS
Cr ane Cr i t i cal Li f t Pl an; G, CS
Pr oof of Qual i f i cat i on f or Cr ane Oper at or s; G, CS
SD- 06 Test Repor t s
Not i f i cat i ons and Repor t s
Submi t r epor t s as t hei r i nci dence occur s, i n accor dance wi t h t he r equi r ement s of t he par agr aph, " Not i f i cat i ons and Repor t s" .
Acci dent Repor t s; G,SO
Cr ane Repor t s
SD- 07 Cer t i f i cat es
Conf i ned Space Ent r y Per mi t
Hot Wor k per mi t
Li cense Cer t i f i cat es
Cer t i f i cat e of Compl i ance
1. 4 REGULATORY REQUI REMENTS
I n addi t i on t o t he det ai l ed r equi r ement s i ncl uded i n t he pr ovi s i ons of t hi s cont r act , compl y wi t h t he most r ecent edi t i on of USACE EM 385- 1- 1, and t he f ol l owi ng f eder al , st at e, and l ocal l aws, or di nances, cr i t er i a, r ul es and r egul at i ons. Submi t mat t er s of i nt er pr et at i on of st andar ds t o t he appr opr i at e admi ni st r at i ve agency f or r esol ut i on bef or e st ar t i ng wor k.
Wher e t he r equi r ement s of t hi s speci f i cat i on, appl i cabl e l aws, cr i t er i a, or di nances, r egul at i ons, and r ef er enced document s var y, t he most st r i ngent r equi r ement s gover n.
SECTI ON 01 35 26 Page 5
1. 5 SI TE QUALI FI CATI ONS, DUTI ES AND MEETI NGS
1. 5. 1 Per sonnel Qual i f i cat i ons
1. 5. 1. 1 Si t e Saf et y and Heal t h Of f i cer ( SSHO)
The SSHO must meet t he r equi r ement s of EM 385- 1- 1 sect i on 1 and ensur e t hat t he r equi r ement s of 29 CFR 1926. 16 ar e met f or t he pr oj ect . Pr ovi de a Saf et y over si ght t eam t hat i ncl udes a mi ni mum of one ( 1) per son at each pr oj ect s i t e t o f unct i on as t he Si t e Saf et y and Heal t h Of f i cer ( SSHO) . The SSHO or an equal l y- qual i f i ed Desi gnat ed Repr esent at i ve/ al t er nat e shal l be at t he wor k s i t e at al l t i mes t o i mpl ement and admi ni st er t he Cont r act or ' s saf et y pr ogr am and gover nment - accept ed Acci dent Pr event i on Pl an. The SSHO' s t r ai ni ng, exper i ence, and qual i f i cat i ons shal l be as r equi r ed by EM 385- 1- 1 par agr aph 01. A. 17, ent i t l ed CONTRACTOR SI TE SAFETY AND HEALTH OFFI CER ( SSHO) , and al l associ at ed sub- par agr aphs.
A Compet ent Per son shal l be pr ovi ded f or al l of t he hazar ds i dent i f i ed i n t he Cont r act or ' s Saf et y and Heal t h Pr ogr am i n accor dance wi t h t he accept ed Acci dent Pr event i on Pl an, and shal l be on- si t e at al l t i mes when t he wor k t hat pr esent s t he hazar ds associ at ed wi t h t hei r pr of essi onal exper t i se i s bei ng per f or med. Pr ovi de t he cr edent i al s of t he Compet ent Per sons( s) t o t he Cont r act i ng Of f i cer f or accept ance i n consul t at i on wi t h t he Saf et y Office.
The Super i nt endent can be t he SSHO, as l ong as t he Super i nt endent meet s al l t he r equi r ement s/ qual i f i cat i ons f or a SSHO. However , i f t he i ndi v i dual pr oves t o be i ncapabl e of per f or mi ng bot h dut i es adequat el y once t he pr oj ect has begun, t he Cont r act or wi l l t hen be r equi r ed t o st af f bot h r ol es separately.
1. 5. 1. 1. 1 Cont r act or Qual i t y Cont r ol ( QC) Per son:
The Cont r act or Qual i t y Cont r ol Per son cannot be t he SSHO on t hi s pr oj ect , even t hough t he QC has saf et y i nspect i on r esponsi bi l i t i es as par t of t he QC duties.
1. 5. 1. 2 Cr ane Oper at or s
Meet t he cr ane oper at or s r equi r ement s i n USACE EM 385- 1- 1, Sect i on 16. I n addi t i on, f or mobi l e cr anes wi t h Or i gi nal Equi pment Manuf act ur er ( OEM) r at ed capaci t at es of 50, 000 pounds or gr eat er , desi gnat e cr ane oper at or s as qual i f i ed by a sour ce t hat qual i f i es cr ane oper at or s ( i . e. , uni on, a gover nment agency, or an or gani zat i on t hat t est s and qual i f i es cr ane oper at or s) . Pr ovi de pr oof of cur r ent qual i f i cat i on.
1. 5. 2 Per sonnel Dut i es
1. 5. 2. 1 Si t e Saf et y and Heal t h Of f i cer ( SSHO)
The SSHO shal l :
a. Conduct dai l y saf et y and heal t h i nspect i ons and mai nt ai n a wr i t t en l og whi ch i ncl udes ar ea/ oper at i on i nspect ed, dat e of i nspect i on, i dent i f i ed hazar ds, r ecommended cor r ect i ve act i ons, est i mat ed and act ual dat es of cor r ect i ons. At t ach saf et y i nspect i on l ogs t o t he Cont r act or s ' dai l y qual i t y cont r ol r epor t .
b. Conduct mi shap i nvest i gat i ons and compl et e r equi r ed r epor t s. Mai nt ai n
SECTI ON 01 35 26 Page 6 t he OSHA For m 300 and Dai l y Pr oduct i on r epor t s f or pr i me and sub-contractors.
c. Mai nt ai n appl i cabl e saf et y r ef er ence mat er i al on t he j ob s i t e.
d. At t end t he pr e- const r uct i on conf er ence, pr e- wor k meet i ngs i ncl udi ng pr epar at or y i nspect i on meet i ng, and per i odi c i n- pr ogr ess meet i ngs.
e. I mpl ement and enf or ce accept ed APPS and AHAs.
f . Mai nt ai n a saf et y and heal t h def i c i ency t r acki ng syst em t hat moni t or s out st andi ng def i c i enci es unt i l r esol ut i on. Post a l i s t of unr esol ved saf et y and heal t h def i c i enci es on t he saf et y bul l et i n boar d.
g. Ensur e sub- cont r act or compl i ance wi t h saf et y and heal t h r equi r ement s.
h. Mai nt ai n a l i s t of hazar dous chemi cal s on s i t e and t hei r mat er i al saf et y dat a sheet s.
Fai l ur e t o per f or m t he above dut i es wi l l r esul t i n di smi ssal of t he super i nt endent , QC Manager , and/ or SSHO, and a pr oj ect wor k st oppage.
The pr oj ect wor k st oppage wi l l r emai n i n ef f ect pendi ng appr oval of a sui t abl e r epl acement .
1. 5. 3 Meetings
1. 5. 3. 1 Pr econst r uct i on Conf er ence
a. Cont r act or r epr esent at i ves who have a r esponsi bi l i t y or s i gni f i cant r ol e i n acci dent pr event i on on t he pr oj ect shal l at t end t he pr econst r uct i on conf er ence. Thi s i ncl udes t he pr oj ect super i nt endent , s i t e saf et y and heal t h of f i cer , qual i t y cont r ol super vi sor , or any ot her assi gned saf et y and heal t h pr of essi onal s who par t i c i pat ed i n t he devel opment of t he APP ( i ncl udi ng t he Act i v i t y Hazar d Anal yses ( AHAs) and speci al pl ans, pr ogr am and pr ocedur es associ at ed wi t h i t ) .
b. Di scuss t he det ai l s of t he submi t t ed APP t o i ncl ude i ncor por at ed pl ans, pr ogr ams, pr ocedur es and a l i s t i ng of ant i c i pat ed AHAs t hat wi l l be devel oped and i mpl ement ed dur i ng t he per f or mance of t he cont r act . Thi s l i s t of pr oposed AHAs wi l l be r evi ewed at t he conf er ence and an agr eement wi l l be r eached bet ween t he Cont r act or and t he Cont r act i ng Of f i cer ' s r epr esent at i ve as t o whi ch phases wi l l r equi r e an anal ysi s.
I n addi t i on, est abl i sh a schedul e f or t he pr epar at i on, submi t t al , r evi ew, and accept ance of AHAs t o pr ecl ude pr oj ect del ays.
c. Def i c i enci es i n t he submi t t ed APP wi l l be br ought t o t he at t ent i on of t he Cont r act or at t he pr econst r uct i on conf er ence, and t he Cont r act or shal l r evi se t he pl an t o cor r ect def i c i enci es and r e- submi t i t f or accept ance. Do not begi n wor k unt i l t her e i s an accept ed APP.
1. 6 ACCI DENT PREVENTI ON PLAN ( APP)
Use a qual i f i ed per son t o pr epar e t he wr i t t en s i t e- speci f i c APP. Pr epar e t he APP i n accor dance wi t h t he f or mat and r equi r ement s of USACE EM 385- 1- 1 and as suppl ement ed her ei n. Cover al l par agr aph and subpar agr aph el ement s i n USACE EM 385- 1- 1, Appendi x A, " Mi ni mum Basi c Out l i ne f or Acci dent Pr event i on Pl an" . Speci f i c r equi r ement s f or some of t he APP el ement s ar e descr i bed bel ow. The APP shal l be j ob- speci f i c and addr ess any unusual or uni que aspect s of t he pr oj ect or act i v i t y f or whi ch i t i s wr i t t en. The APP
SECTI ON 01 35 26 Page 7 shal l i nt er f ace wi t h t he Cont r act or ' s over al l saf et y and heal t h pr ogr am.
I ncl ude any por t i ons of t he Cont r act or ' s over al l saf et y and heal t h pr ogr am r ef er enced i n t he APP i n t he appl i cabl e APP el ement and made si t e- speci f i c .
The Gover nment consi der s t he Pr i me Cont r act or t o be t he " cont r ol l i ng aut hor i t y" f or al l wor k s i t e saf et y and heal t h of t he subcont r act or s.
Cont r act or s ar e r esponsi bl e f or i nf or mi ng t hei r subcont r act or s of t he saf et y pr ovi s i ons under t he t er ms of t he cont r act and t he penal t i es f or noncompl i ance, coor di nat i ng t he wor k t o pr event one cr af t f r om i nt er f er i ng wi t h or cr eat i ng hazar dous wor ki ng condi t i ons f or ot her cr af t s, and i nspect i ng subcont r act or oper at i ons t o ensur e t hat acci dent pr event i on r esponsi bi l i t i es ar e bei ng car r i ed out . The APP shal l be s i gned by t he per son and f i r m ( seni or per son) pr epar i ng t he APP, t he Cont r act or , t he on- si t e super i nt endent , t he desi gnat ed s i t e saf et y and heal t h of f i cer , t he Cont r act or Qual i t y cont r ol Manager , and any desi gnat ed CSP or CI H.
Submi t t he APP t o t he Cont r act i ng Of f i cer 15 cal endar days pr i or t o t he dat e of t he pr econst r uct i on conf er ence f or accept ance. Wor k cannot pr oceed wi t hout an accept ed APP.
Once accept ed by t he Cont r act i ng Of f i cer , t he APP and at t achment s wi l l be enf or ced as par t of t he cont r act . Di sr egar di ng t he pr ovi s i ons of t hi s cont r act or t he accept ed APP wi l l be cause f or st oppi ng of wor k, at t he di scr et i on of t he Cont r act i ng Of f i cer , unt i l t he mat t er has been r ect i f i ed.
Once wor k begi ns, changes t o t he accept ed APP shal l be made wi t h t he knowl edge and concur r ence of t he Cont r act i ng Of f i cer , pr oj ect super i nt endent , SSHO and qual i t y cont r ol manager . Shoul d any sever e hazar d exposur e, i . e. i mmi nent danger , become evi dent , st op wor k i n t he ar ea, secur e t he ar ea, and devel op a pl an t o r emove t he exposur e and cont r ol t he hazar d. Not i f y t he Cont r act i ng Of f i cer wi t hi n 24 hour s of di scover y.
El i mi nat e/ r emove t he hazar d. I n t he i nt er i m, t ake al l necessar y act i on t o r est or e and mai nt ai n saf e wor ki ng condi t i ons i n or der t o saf eguar d onsi t e per sonnel , v i s i t or s, t he publ i c ( as def i ned by ASSE/ SAFE A10. 34, ) and t he environment.
Copi es of t he accept ed pl an wi l l be mai nt ai ned at t he Cont r act i ng Of f i cer ' s of f i ce and at t he j ob s i t e. Cont i nuousl y r evi ew and amend t he APP, as necessar y, t hr oughout t he l i f e of t he cont r act . I ncor por at e unusual or hi gh- hazar d act i v i t i es not i dent i f i ed i n t he or i gi nal APP as t hey ar e discovered.
1. 6. 1 EM 385- 1- 1 Cont ent s
I n addi t i on t o t he r equi r ement s out l i ned i n Appendi x A of USACE EM 385- 1- 1, t he f ol l owi ng i s r equi r ed:
a. Cr ane Cr i t i cal Li f t Pl an.
Pr epar e and si gn wei ght handl i ng cr i t i cal l i f t pl ans f or l i f t s over 75 per cent of t he capaci t y of t he cr ane or hoi st ( or l i f t s over 50 per cent of t he capaci t y of a bar ge mount ed mobi l e cr ane' s hoi st s) at any r adi us of l i f t ; l i f t s i nvol v i ng mor e t han one cr ane or hoi st ; l i f t s of per sonnel ; and l i f t s i nvol v i ng non- r out i ne r i ggi ng or oper at i on, sensi t i ve equi pment , or unusual saf et y r i sks. Submi t 15 cal endar days pr i or t o on- si t e wor k and i ncl ude t he r equi r ement s of USACE EM 385- 1- 1, par agr aph 16. H. and t he following:
( 1) For l i f t s of per sonnel , demonst r at e compl i ance wi t h t he r equi r ement s of
29 CFR 1926. 1400.
SECTI ON 01 35 26 Page 8
b. Si t e Saf et y and Heal t h Pl an. The saf et y and heal t h aspect s pr epar ed i n accor dance wi t h Sect i on 01 35 29. 13 HEALTH, SAFETY, AND EMERGENCY
RESPONSE PROCEDURES FOR CONTAMI NATED SI TES.
c. Excavat i on Pl an. The saf et y and heal t h aspect s pr epar ed i n accor dance wi t h Sect i on 31 23 00. 00 20 EXCAVATI ON AND FI LL.
1. 7 ACTI VI TY HAZARD ANALYSI S ( AHA)
The Act i v i t y Hazar d Anal ysi s ( AHA) f or mat shal l be i n accor dance wi t h USACE EM 385- 1- 1, Sect i on 1. Submi t t he AHA f or r evi ew at l east 15 cal endar days pr i or t o t he st ar t of each phase. For mat subsequent AHAs as amendment s t o t he APP. The anal ysi s shoul d be used dur i ng dai l y i nspect i ons t o ensur e t he i mpl ement at i on and ef f ect i veness of t he act i v i t y ' s saf et y and heal t h controls.
The AHA l i s t wi l l be r evi ewed per i odi cal l y ( at l east mont hl y) at t he Cont r act or super vi sor y saf et y meet i ng and updat ed as necessar y when pr ocedur es, schedul i ng, or hazar ds change.
Devel op t he act i v i t y hazar d anal yses usi ng t he pr oj ect schedul e as t he basi s f or t he act i v i t i es per f or med. Any act i v i t i es l i s t ed on t he pr oj ect schedul e wi l l r equi r e an AHA. The AHAs wi l l be devel oped by t he cont r act or , suppl i er or subcont r act or and pr ovi ded t o t he pr i me cont r act or f or submi t t al t o t he Cont r act i ng Of f i cer .
1. 8 DI SPLAY OF SAFETY I NFORMATI ON
Wi t hi n one cal endar day af t er commencement of wor k, er ect a saf et y bul l et i n boar d at t he j ob s i t e. Wher e s i ze, dur at i on, or l ogi st i cs of pr oj ect do not f aci l i t at e a bul l et i n boar d, an al t er nat i ve met hod, accept abl e t o t he Cont r act i ng Of f i cer , t hat i s accessi bl e and i ncl udes al l mandat or y i nf or mat i on f or empl oyee and vi s i t or r evi ew, shal l be deemed as meet i ng t he r equi r ement f or a bul l et i n boar d. I ncl ude and mai nt ai n i nf or mat i on on saf et y bul l et i n boar d as r equi r ed by EM 385- 1- 1, sect i on 01. A. 07.
Addi t i onal i t ems r equi r ed t o be post ed i ncl ude:
a. Conf i ned space ent r y per mi t .
b. Hot wor k per mi t .
1. 9 SI TE SAFETY REFERENCE MATERI ALS
Mai nt ai n saf et y- r el at ed r ef er ences appl i cabl e t o t he pr oj ect , i ncl udi ng t hose l i s t ed i n t he ar t i c l e " Ref er ences. " Mai nt ai n appl i cabl e equi pment manuf act ur er ' s manual s.
1. 10 EMERGENCY MEDI CAL TREATMENT
Cont r act or s wi l l ar r ange f or t hei r own emer gency medi cal t r eat ment .
Gover nment has no r esponsi bi l i t y t o pr ovi de emer gency medi cal t r eat ment .
1. 11 NOTI FI CATI ONS and REPORTS
1. 11. 1 Acci dent Not i f i cat i on
Not i f y t he Cont r act i ng Of f i cer as soon as pr act i cal , but no mor e t han f our hour s af t er any acci dent meet i ng t he def i ni t i on of Recor dabl e I nj ur i es or
SECTI ON 01 35 26 Page 9
I l l nesses or Hi gh Vi s i bi l i t y Acci dent s, pr oper t y damage equal t o or gr eat er t han $2, 000, or any wei ght handl i ng equi pment acci dent . Wi t hi n not i f i cat i on i nc l ude cont r act or name; cont r act t i t l e; t ype of cont r act ;
name of act i v i t y , i nst al l at i on or l ocat i on wher e acci dent occur r ed; dat e and t i me of acci dent ; names of per sonnel i nj ur ed; ext ent of pr oper t y damage, i f any; ext ent of i nj ur y, i f known, and br i ef descr i pt i on of acci dent ( t o i nc l ude t ype of const r uct i on equi pment used, PPE used, et c. ) .
Pr eser ve t he condi t i ons and evi dence on t he acci dent s i t e unt i l t he Gover nment i nvest i gat i on t eam ar r i ves on- si t e and Gover nment i nvest i gat i on i s conduct ed.
1. 11. 2 Acci dent Repor t s
a. Conduct an acci dent i nvest i gat i on f or r ecor dabl e i nj ur i es and i l l nesses, f or Medi cal Tr eat ment def i ned i n par agr aph DEFI NI TI ONS, pr oper t y damage acci dent s r esul t i ng i n at l east $5, 000 i n damages, and near mi sses as def i ned i n EM 385- 1- 1, t o est abl i sh t he r oot cause( s) of t he acci dent . The Cont r act i ng Of f i cer wi l l pr ovi de copi es of any r equi r ed or speci al f or ms.
b. Conduct an acci dent i nvest i gat i on f or any wei ght handl i ng equi pment acci dent ( i ncl udi ng r i ggi ng gear acci dent s) t o est abl i sh t he r oot cause( s) of t he acci dent , compl et e t he WHE Acci dent Repor t ( Cr ane and Ri ggi ng Gear ) f or m and pr ovi de t he r epor t t o t he Cont r act i ng Of f i cer wi t hi n 30 cal endar days of t he acci dent . Do not pr oceed wi t h cr ane oper at i ons unt i l cause i s det er mi ned and cor r ect i ve act i ons have been i mpl ement ed t o t he sat i sf act i on of t he cont r act i ng of f i cer . The Cont r act i ng Of f i cer wi l l pr ovi de a bl ank copy of t he acci dent r epor t form.
1. 11. 3 Cr ane Repor t s
Submi t cr ane i nspect i on r epor t s r equi r ed i n accor dance wi t h USACE EM 385- 1- 1 and For m 16- 2 and as speci f i ed her ei n wi t h Dai l y Repor t s of I nspect i ons.
1. 11. 4 Cer t i f i cat e of Compl i ance
Pr ovi de a Cer t i f i cat e of Compl i ance f or each cr ane ent er i ng an act i v i t y under t hi s cont r act ( see Cont r act i ng Of f i cer f or a bl ank cer t i f i cat e) .
St at e wi t hi n t he cer t i f i cat e t hat t he cr ane and r i ggi ng gear meet appl i cabl e OSHA r egul at i ons ( wi t h t he Cont r act or c i t i ng whi ch OSHA r egul at i ons ar e appl i cabl e, e. g. , cr anes used i n const r uct i on, demol i t i on, or mai nt enance compl y wi t h 29 CFR 1926 and USACE EM 385- 1- 1 Sect i on 16 and For m 16- 1. Cer t i f y on t he Cer t i f i cat e of Compl i ance t hat t he cr ane oper at or ( s) i s qual i f i ed and t r ai ned i n t he oper at i on of t he cr ane t o be used. Al so cer t i f y t hat al l of i t s cr ane oper at or s wor ki ng on t he DOD act i v i t y have been t r ai ned i n t he pr oper use of al l saf et y devi ces ( e. g. , ant i - t wo bl ock devi ces) . Post cer t i f i cat i ons on t he cr ane.
1. 12 HOT WORK
Submi t and obt ai n a wr i t t en per mi t pr i or t o per f or mi ng " Hot Wor k" ( wel di ng, cut t i ng, et c. ) or oper at i ng ot her f l ame- pr oduci ng/ spar k pr oduci ng devi ces, f r om t he Fi r e Di v i s i on. A per mi t i s r equi r ed f r om t he Expl osi ves Saf et y Of f i ce f or wor k i n and ar ound wher e expl osi ves ar e pr ocessed, st or ed, or handl ed. CONTRACTORS ARE REQUI RED TO MEET ALL CRI TERI A BEFORE A PERMI T I S I SSUED. Pr ovi de at l east t wo ( 2) t went y ( 20) pound 4A: 20 BC r at ed ext i ngui sher s f or nor mal " Hot Wor k" . Al l ext i ngui sher s shal l be cur r ent i nspect i on t agged, appr oved saf et y pi n and t amper r esi st ant seal . I t i s
SECTI ON 01 35 26 Page 10 al so mandat or y t o have a desi gnat ed FI RE WATCH f or any " Hot Wor k" done at t hi s act i v i t y. The Fi r e Wat ch shal l be t r ai ned i n accor dance wi t h NFPA 51B and r emai n on- si t e f or a mi ni mum of 30 mi nut es af t er compl et i on of t he t ask or as speci f i ed on t he hot wor k per mi t .
When st ar t i ng wor k i n t he f aci l i t y , r equi r e per sonnel t o f ami l i ar i ze t hemsel ves wi t h t he l ocat i on of t he near est f i r e al ar m boxes and pl ace i n memor y t he emer gency Fi r e Di v i s i on phone number . ANY FI RE, NO MATTER HOW
SMALL, SHALL BE REPORTED TO THE RESPONSI BLE FI RE DI VI SI ON I MMEDI ATELY.
1. 13 RADI ATI ON SAFETY REQUI REMENTS
Li cense Cer t i f i cat es f or r adi at i on mat er i al s and equi pment shal l be submi t t ed t o t he Cont r act i ng Of f i cer and Radi at i on Saf et y Of f i ce ( RSO) f or al l speci al i zed and l i censed mat er i al and equi pment t hat coul d cause f at al har m t o const r uct i on per sonnel or t o t he const r uct i on pr oj ect .
Wor ker s shal l be pr ot ect ed f r om r adi at i on exposur e i n accor dance wi t h 10 CFR 20. St andar ds f or Pr ot ect i on Agai nst Radi at i on
Loss of r adi oact i ve mat er i al shal l be r epor t ed i mmedi at el y t o t he Cont r act i ng Of f i cer .
Act ual exposur e of t he r adi ogr aphi c f i l m or unshi el di ng t he sour ce shal l not be i ni t i at ed unt i l af t er 5 p. m. on weekdays.
I n i nst ances wher e r adi ogr aphy i s schedul ed near or adj acent t o bui l di ngs or ar eas havi ng l i mi t ed access or one- way door s, no assumpt i ons shal l be made as t o bui l di ng occupancy. Wher e necessar y, t he Cont r act i ng Of f i cer wi l l di r ect t he Cont r act or t o conduct an act ual bui l di ng ent r y, sear ch, and al er t . Wher e r emoval of per sonnel f r om such a bui l di ng cannot be accompl i shed and i t i s ot her wi se saf e t o pr oceed wi t h t he r adi ogr aphy, a f ul l y i nst r uct ed empl oyee shal l be posi t i oned i nsi de such bui l di ng or ar ea t o pr event exi t i ng whi l e ext er nal r adi ogr aphi c oper at i ons ar e i n pr ocess.
Tr anspor t at i on of Regul at ed Amount s of Radi oact i ve Mat er i al wi l l compl y wi t h 49 CFR, Subchapt er C, Hazar dous Mat er i al Regul at i ons. Local Fi r e aut hor i t i es and t he s i t e Radi at i on Saf et y of f i cer ( RSO) shal l be not i f i ed of any Radi oact i ve Mat er i al use.
Tr ansmi t t er Requi r ement s: The base pol i cy concer ni ng t he use of t r ansmi t t er s such as r adi os, cel l phones, et c. , must be adher ed t o by al l cont r act or per sonnel . They must al so obey Emi ssi ons cont r ol ( EMCON) restrictions.
1. 14 FACI LI TY OCCUPANCY CLOSURE
St r eet s, wal ks, and ot her f aci l i t i es occupi ed and used by t he Gover nment shal l not be c l osed or obst r uct ed wi t hout wr i t t en per mi ssi on f r om t he Cont r act i ng Of f i cer .
1. 15 SEVERE STORM PLAN
I n t he event of a sever e st or m war ni ng, t he Cont r act or must :
a. Secur e out s i de equi pment and mat er i al s and pl ace mat er i al s t hat coul d be damaged i n pr ot ect ed ar eas.
b. Check sur r oundi ng ar ea, i ncl udi ng r oof , f or l oose mat er i al , equi pment , debr i s, and ot her obj ect s t hat coul d be bl own away or agai nst exi st i ng
SECTI ON 01 35 26 Page 11 facilities.
c. Ensur e t hat t empor ar y er osi on cont r ol s ar e adequat e.
1. 16 CONFI NED SPACE ENTRY REQUI REMENTS.
Cont r act or s ent er i ng and wor ki ng i n conf i ned spaces whi l e per f or mi ng gener al i ndust r y wor k ar e r equi r ed t o f ol l ow t he r equi r ement s of OSHA 29 CFR 1926 and compl y wi t h t he r equi r ement s i n Sect i on 34 of EM 385- 1- 1, OSHA 29 CFR 1910, and OSHA 29 CFR 1910. 146.
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON
3. 1 CONSTRUCTI ON AND OTHER WORK
3. 1. 1 Hazar dous Mat er i al Excl usi ons
Not wi t hst andi ng any ot her hazar dous mat er i al used i n t hi s cont r act , r adi oact i ve mat er i al s or i nst r ument s capabl e of pr oduci ng i oni z i ng/ non- i oni z i ng r adi at i on ( wi t h t he except i on of r adi oact i ve mat er i al and devi ces used i n accor dance wi t h USACE EM 385- 1- 1 such as nucl ear densi t y met er s f or compact i on t est i ng and l abor at or y equi pment wi t h r adi oact i ve sour ces) as wel l as mat er i al s whi ch cont ai n asbest os, mer cur y or pol ychl or i nat ed bi phenyl s, di - i socynat es, l ead- based pai nt ar e pr ohi bi t ed. The Cont r act i ng Of f i cer , upon wr i t t en r equest by t he Cont r act or , may consi der except i ons t o t he use of any of t he above excl uded mat er i al s. Low mer cur y l amps used wi t hi n f l uor escent l i ght i ng f i x t ur es ar e al l owed as an except i on wi t hout f ur t her Cont r act i ng Of f i cer appr oval .
Not i f y t he Radi at i on Saf et y Of f i cer ( RSO) pr i or t o except ed i t ems of r adi oact i ve mat er i al and devi ces bei ng br ought on base.
3. 1. 2 Unf or eseen Hazar dous Mat er i al
The desi gn shoul d have i dent i f i ed mat er i al s such as PCB, l ead pai nt , and f r i abl e and non- f r i abl e asbest os and ot her OSHA r egul at ed chemi cal s ( i . e.
29 CFR Par t 1910. 1000) . I f addi t i onal mat er i al , not i ndi cat ed, t hat may be hazar dous t o human heal t h upon di st ur bance dur i ng const r uct i on oper at i ons i s encount er ed, st op t hat por t i on of wor k and not i f y t he Cont r act i ng Of f i cer i mmedi at el y. Wi t hi n 14 cal endar days t he Gover nment wi l l det er mi ne i f t he mat er i al i s hazar dous. I f mat er i al i s not hazar dous or poses no danger , t he Gover nment wi l l di r ect t he Cont r act or t o pr oceed wi t hout change. I f mat er i al i s hazar dous and handl i ng of t he mat er i al i s necessar y t o accompl i sh t he wor k, t he Gover nment wi l l i ssue a modi f i cat i on pur suant t o " FAR 52. 243- 4, Changes" and " FAR 52. 236- 2, Di f f er i ng Si t e Condi t i ons. "
3. 2 PRE- OUTAGE COORDI NATI ON MEETI NG
Appl y f or ut i l i t y out ages at l east 15 days i n advance. As a mi ni mum, t he r equest shoul d i ncl ude t he l ocat i on of t he out age, ut i l i t i es bei ng af f ect ed, dur at i on of out age and any necessar y sket ches. Speci al r equi r ement s f or el ect r i cal out age r equest s ar e cont ai ned el sewher e i n t hi s speci f i cat i on sect i on. Once appr oved, and pr i or t o begi nni ng wor k on t he ut i l i t y syst em r equi r i ng shut down, at t end a pr e- out age coor di nat i on meet i ng wi t h t he Cont r act i ng Of f i cer and t he Publ i c Ut i l i t i es r epr esent at i ve t o r evi ew t he scope of wor k and t he l ock- out / t ag- out pr ocedur es f or wor ker pr ot ect i on. No wor k wi l l be per f or med on ener gi zed
SECTI ON 01 35 26 Page 12 el ect r i cal c i r cui t s unl ess pr oof i s pr ovi ded t hat no ot her means exi st .
3. 3 CONTROL OF HAZARDOUS ENERGY ( LOCKOUT/ TAGOUT)
Ensur e t hat each empl oyee i s f ami l i ar wi t h and compl i es wi t h t hese pr ocedur es and USACE EM 385- 1- 1, Sect i on 12, Cont r ol of Hazar dous Ener gy.
3. 4 FALL HAZARD PROTECTI ON AND PREVENTI ON PROGRAM
Est abl i sh a f al l pr ot ect i on and pr event i on pr ogr am, f or t he pr ot ect i on of al l empl oyees exposed t o f al l hazar ds. Wi t hi n t he pr ogr am i ncl ude company pol i cy, i dent i f y r esponsi bi l i t i es, educat i on and t r ai ni ng r equi r ement s, f al l hazar d i dent i f i cat i on, pr event i on and cont r ol measur es, i nspect i on, st or age, car e and mai nt enance of f al l pr ot ect i on equi pment and r escue and evacuat i on pr ocedur es i n accor dance wi t h ASSE/ SAFE Z359. 1.
3. 4. 1 Training
I nst i t ut e a f al l pr ot ect i on t r ai ni ng pr ogr am. As par t of t he Fal l Hazar d Pr ot ect i on and Pr event i on Pr ogr am, pr ovi de t r ai ni ng f or each empl oyee who mi ght be exposed t o f al l hazar ds. Pr ovi de t r ai ni ng by a compet ent per son f or f al l pr ot ect i on i n accor dance wi t h USACE EM 385- 1- 1, Sect i on 21. C.
3. 4. 2 Fal l Pr ot ect i on Equi pment and Syst ems
Enf or ce use of t he f al l pr ot ect i on equi pment and syst ems desi gnat ed f or each speci f i c wor k act i v i t y i n t he Fal l Pr ot ect i on and Pr event i on Pl an and/ or AHA at al l t i mes when an empl oyee i s exposed t o a f al l hazar d.
Pr ot ect empl oyees f r om f al l hazar ds as speci f i ed i n EM 385- 1- 1, Sect i on
21. I n addi t i on t o t he r equi r ed f al l pr ot ect i on syst ems, saf et y sk i f f , per sonal f l oat at i on devi ces, l i f e r i ngs et c. , ar e r equi r ed when wor ki ng above or next t o wat er i n accor dance wi t h USACE EM 385- 1- 1, Par agr aphs 21. O t hr ough 21. O. 04. Per sonal f al l ar r est syst ems ar e r equi r ed when wor ki ng f r om an ar t i cul at i ng or ext endi bl e boom, swi ng st ages, or suspended pl at f or m. I n addi t i on, per sonal f al l ar r est syst ems ar e r equi r ed when oper at i ng ot her equi pment such as sci ssor l i f t s i f t he wor k pl at f or m i s capabl e of bei ng posi t i oned out s i de t he wheel base. The need f or t y i ng- of f i n such equi pment i s t o pr event ej ect i on of t he empl oyee f r om t he equi pment dur i ng r ai s i ng, l ower i ng, or t r avel . Fal l pr ot ect i on must compl y wi t h 29 CFR 1926. 500, Subpar t M, USACE EM 385- 1- 1 and ASSE/ SAFE A10. 32.
3. 4. 2. 1 Per sonal Fal l Ar r est Equi pment
Per sonal f al l ar r est equi pment , syst ems, subsyst ems, and component s shal l meet ASSE/ SAFE Z359. 1. Onl y a f ul l - body har ness wi t h a shock- absor bi ng l anyar d or sel f - r et r act i ng l anyar d i s an accept abl e per sonal f al l ar r est body suppor t devi ce. Body bel t s may onl y be used as a posi t i oni ng devi ce syst em ( f or uses such as st eel r ei nf or c i ng assembl y and i n addi t i on t o an appr oved f al l ar r est syst em) . Har nesses shal l have a f al l ar r est at t achment af f i xed t o t he body suppor t ( usual l y a Dor sal D- r i ng) and speci f i cal l y desi gnat ed f or at t achment t o t he r est of t he syst em. Onl y l ocki ng snap hooks and car abi ner s shal l be used. Webbi ng, st r aps, and r opes shal l be made of synt het i c f i ber . The maxi mum f r ee f al l di st ance when usi ng f al l ar r est equi pment shal l not exceed si x ( 6) f eet . The t ot al f al l di st ance and any swi ngi ng of t he wor ker ( pendul um- l i ke mot i on) t hat can occur dur i ng a f al l shal l al ways be t aken i nt o consi der at i on when at t achi ng a per son t o a f al l ar r est syst em.
SECTI ON 01 35 26 Page 13
3. 4. 3 Fal l Pr ot ect i on f or Roof i ng Wor k
I mpl ement f al l pr ot ect i on cont r ol s based on t he t ype of r oof bei ng const r uct ed and wor k bei ng per f or med. Eval uat e t he r oof ar ea t o be accessed f or i t s st r uct ur al i nt egr i t y i ncl udi ng wei ght - bear i ng capabi l i t i es f or t he pr oj ect ed l oadi ng.
a. Low Sl oped Roof s:
( 1) For wor k wi t hi n s i x ( 6) f eet of an edge, on l ow- sl ope r oof s, pr ot ect per sonnel f r om f al l i ng by use of per sonal f al l ar r est syst ems, guar dr ai l s , or saf et y net s.
( 2) For wor k gr eat er t han s i x ( 6) f eet f r om an edge, er ect and i nst al l war ni ng l i nes i n accor dance wi t h 29 CFR 1926. 500 and USACE
EM 385- 1- 1.
b. St eep- Sl oped Roof s: Wor k on st eep- sl oped r oof s r equi r es a per sonal f al l ar r est syst em, guar dr ai l s wi t h t oe- boar ds, or saf et y net s. Thi s r equi r ement al so i ncl udes r esi dent i al or housi ng t ype const r uct i on.
3. 4. 4 Hor i zont al Li f el i nes
Desi gn, i nst al l , cer t i f y and use under t he super vi s i on of a qual i f i ed per son hor i zont al l i f el i nes f or f al l pr ot ect i on as par t of a compl et e f al l ar r est syst em whi ch mai nt ai ns a saf et y f act or of 2 ( 29 CFR 1926. 500).
3. 4. 5 Guar dr ai l s and Saf et y Net s
Desi gn, i nst al l and use guar dr ai l s and saf et y net s i n accor dance wi t h EM 385- 1- 1 and 29 CFR 1926 Subpar t M.
3. 4. 6 Rescue and Evacuat i on Pr ocedur es
When per sonal f al l ar r est syst ems ar e used, ensur e t hat t he mi shap vi ct i m can sel f - r escue or can be r escued pr ompt l y shoul d a f al l occur . Pr epar e a Rescue and Evacuat i on Pl an and i ncl ude a det ai l ed di scussi on of t he f ol l owi ng: met hods of r escue; met hods of sel f - r escue; equi pment used;
t r ai ni ng r equi r ement ; speci al i zed t r ai ni ng f or t he r escuer s; pr ocedur es f or r equest i ng r escue and medi cal assi st ance; and t r anspor t at i on r out es t o a medi cal f aci l i t y . I ncl ude t he Rescue and Evacuat i on Pl an wi t hi n t he Act i v i t y Hazar d Anal ysi s ( AHA) f or t he phase of wor k, i n t he Fal l Pr ot ect i on and Pr event i on ( FP&P) Pl an, and t he Acci dent Pr event i on Pl an
(APP).
3. 5 EQUIPMENT
3. 5. 1 Mat er i al Handl i ng Equi pment
a. Mat er i al handl i ng equi pment such as f or k l i f t s shal l not be modi f i ed wi t h wor k pl at f or m at t achment s f or suppor t i ng empl oyees unl ess speci f i cal l y del i neat ed i n t he manuf act ur er ' s pr i nt ed oper at i ng instructions.
b. The use of hooks on equi pment f or l i f t i ng of mat er i al must be i n accor dance wi t h manuf act ur er ' s pr i nt ed i nst r uct i ons.
c. Oper at or s of f or k l i f t s or power i ndust r i al t r ucks shal l be l i censed i n accor dance wi t h OSHA.
SECTI ON 01 35 26 Page 14
3. 5. 2 Wei ght Handl i ng Equi pment
a. Equi p cr anes and der r i cks as speci f i ed i n EM 385- 1- 1, sect i on 16.
b. Compl y wi t h t he cr ane manuf act ur er ' s speci f i cat i ons and l i mi t at i ons f or er ect i on and oper at i on of cr anes and hoi st s used i n suppor t of t he wor k. Per f or m er ect i on under t he super vi s i on of a desi gnat ed per son ( as def i ned i n ASME B30. 5) . Per f or m al l t est i ng i n accor dance wi t h t he manuf act ur er ' s r ecommended pr ocedur es.
c. Compl y wi t h ASME B30. 5 f or mobi l e and l ocomot i ve cr anes, ASME B30. 22 f or ar t i cul at i ng boom cr anes, ASME B30. 3 f or const r uct i on t ower cr anes, and ASME B30. 8 f or f l oat i ng cr anes and f l oat i ng der r i cks.
d. Under no c i r cumst ance shal l a Cont r act or make a l i f t at or above 90 per cent of t he cr anes r at ed capaci t y i n any conf i gur at i on.
e. When oper at i ng i n t he v i c i ni t y of over head t r ansmi ssi on l i nes, oper at or s and r i gger s shal l be al er t t o t hi s speci al hazar d and f ol l ow t he r equi r ement s of USACE EM 385- 1- 1 Sect i on 11 and ASME B30. 5 or ASME B30. 22 as appl i cabl e.
f . Do not cr ane suspended per sonnel wor k pl at f or ms ( basket s) unl ess t he Cont r act or pr oves t hat usi ng any ot her access t o t he wor k l ocat i on woul d pr ovi de a gr eat er hazar d t o t he wor ker s or i s i mpossi bl e. Do not l i f t per sonnel wi t h a l i ne hoi st or f r i c t i on cr ane.
g. I nspect , mai nt ai n, and r echar ge por t abl e f i r e ext i ngui sher s as speci f i ed i n NFPA 10, St andar d f or Por t abl e Fi r e Ext i ngui sher s.
h. Al l empl oyees must keep cl ear of l oads about t o be l i f t ed and of suspended l oads.
i . Use cr i bbi ng when per f or mi ng l i f t s on out r i gger s.
j . The cr ane hook/ bl ock must be posi t i oned di r ect l y over t he l oad. Si de l oadi ng of t he cr ane i s pr ohi bi t ed.
k. A physi cal bar r i cade must be posi t i oned t o pr event per sonnel f r om ent er i ng t he count er wei ght swi ng ( t ai l swi ng) ar ea of t he cr ane.
l . Cer t i f i cat i on r ecor ds whi ch i ncl ude t he dat e of i nspect i on, s i gnat ur e of t he per son per f or mi ng t he i nspect i on, and t he ser i al number or ot her i dent i f i er of t he cr ane t hat was i nspect ed shal l al ways be avai l abl e f or r evi ew by Cont r act i ng Of f i cer per sonnel .
m. Wr i t t en r epor t s l i s t i ng t he l oad t est pr ocedur es used al ong wi t h any r epai r s or al t er at i ons per f or med on t he cr ane shal l be avai l abl e f or r evi ew by Cont r act i ng Of f i cer per sonnel .
o. Cer t i f y t hat al l cr ane oper at or s have been t r ai ned i n pr oper use of al l saf et y devi ces ( e. g. ant i - t wo bl ock devi ces) .
3. 5. 3 USE OF EXPLOSI VES
Expl osi ves shal l not be used or br ought t o t he pr oj ect s i t e wi t hout pr i or wr i t t en appr oval f r om t he Cont r act i ng Of f i cer . Such appr oval shal l not r el i eve t he Cont r act or of r esponsi bi l i t y f or i nj ur y t o per sons or f or
SECTI ON 01 35 26 Page 15 damage t o pr oper t y due t o bl ast i ng oper at i ons.
St or age of expl osi ves, when per mi t t ed on Gover nment pr oper t y, shal l be onl y wher e di r ect ed and i n appr oved st or age f aci l i t i es. These f aci l i t i es shal l be kept l ocked at al l t i mes except f or i nspect i on, del i ver y, and wi t hdr awal of expl osi ves.
3. 6 EXCAVATIONS
Soi l c l assi f i cat i on must be per f or med by a compet ent per son i n accor dance with 29 CFR 1926 and EM 385- 1- 1.
3. 6. 1 Ut i l i t y Locat i ons
Al l under gr ound ut i l i t i es i n t he wor k ar ea must be posi t i vel y i dent i f i ed by a t hi r d par t y, i ndependent , pr i vat e ut i l i t y l ocat i ng company i n addi t i on t o any st at i on l ocat i ng ser vi ce and coor di nat ed wi t h t he st at i on ut i l i t y department.
3. 6. 2 Ut i l i t y Locat i on Ver i f i cat i on
Physi cal l y ver i f y under gr ound ut i l i t y l ocat i ons, i ncl udi ng ut i l i t y dept h, by hand di ggi ng usi ng wood or f i ber gl ass handl ed t ool s when any adj acent const r uct i on wor k i s expect ed t o come wi t hi n t hr ee f eet of t he under gr ound system.
3. 6. 3 Ut i l i t i es Wi t hi n and Under Concr et e, Bi t umi nous Asphal t , and Ot her I mper vi ous Sur f aces
Ut i l i t i es l ocat ed wi t hi n and under concr et e s l abs or pi er st r uct ur es, br i dges, par ki ng ar eas, and t he l i ke, ar e ext r emel y di f f i cul t t o i dent i f y.
Whenever cont r act wor k i nvol ves chi ppi ng, saw cut t i ng, or cor e dr i l l i ng t hr ough concr et e, bi t umi nous asphal t or ot her i mper vi ous sur f aces, t he exi st i ng ut i l i t y l ocat i on must be coor di nat ed wi t h st at i on ut i l i t y depar t ment s i n addi t i on t o l ocat i on and dept h ver i f i cat i on by a t hi r d par t y, i ndependent , pr i vat e l ocat i ng company. The t hi r d par t y, i ndependent , pr i vat e l ocat i ng company shal l l ocat e ut i l i t y dept h by use of Gr ound Penet r at i ng Radar ( GPR) , X- r ay, bor e scope, or ul t r asound pr i or t o t he st ar t of demol i t i on and const r uct i on. Out ages t o i sol at e ut i l i t y syst ems must be used i n c i r cumst ances wher e ut i l i t i es ar e unabl e t o be posi t i vel y i dent i f i ed. The use of hi st or i cal dr awi ngs does not al l evi at e t he cont r act or f r om meet i ng t hi s r equi r ement .
3. 7 ELECTRICAL
3. 7. 1 3. 9. 1 Por t abl e Ext ensi on Cor ds
Si ze por t abl e ext ensi on cor ds i n accor dance wi t h manuf act ur er r at i ngs f or t he t ool t o be power ed and pr ot ect ed f r om damage. I mmedi at el y r emoved f r om ser vi ce al l damaged ext ensi on cor ds. Por t abl e ext ensi on cor ds shal l meet t he r equi r ement s of EM 385- 1- 1, NFPA 70E, and OSHA el ect r i cal st andar ds.
3. 8 WORK I N CONFI NED SPACES
Compl y wi t h t he r equi r ement s i n Sect i on 34 of USACE EM 385- 1- 1, OSHA 29 CFR 1910, OSHA 29 CFR 1910. 146, OSHA Di r ect i ve CPL 2. 100 and OSHA 29 CFR 1926. Any pot ent i al f or a hazar d i n t he conf i ned space r equi r es a per mi t syst em t o be used.
SECTI ON 01 35 26 Page 16
a. Ent r y Pr ocedur es. Pr ohi bi t ent r y i nt o a conf i ned space by per sonnel f or any pur pose, i ncl udi ng hot wor k, unt i l t he qual i f i ed per son has conduct ed appr opr i at e t est s t o ensur e t he conf i ned or encl osed space i s saf e f or t he wor k i nt ended and t hat al l pot ent i al hazar ds ar e cont r ol l ed or el i mi nat ed and document ed. ( See Sect i on 34 of USACE EM 385- 1- 1 f or ent r y pr ocedur es. ) Al l hazar ds per t ai ni ng t o t he space shal l be r evi ewed wi t h each empl oyee dur i ng r evi ew of t he AHA.
b. For ced ai r vent i l at i on i s r equi r ed f or al l conf i ned space ent r y oper at i ons and t he mi ni mum ai r exchange r equi r ement s must be mai nt ai ned t o ensur e exposur e t o any hazar dous at mospher e i s kept bel ow i t s ' act i on l evel .
c. Sewer wet wel l s r equi r e cont i nuous at mospher e moni t or i ng wi t h audi bl e al ar m f or t oxi c gas det ect i on.
- - End of Sect i on - -
SECTI ON 01 35 26 Page 17
DI VI SI ON 31 - EARTHWORK
SECTI ON 31 23 00. 00 20
EXCAVATI ON AND FI LL
02/11
PART 1 GENERAL
1. 1 SCOPE
1. 2 REFERENCES
1. 3 DEFI NI TI ONS
1. 3. 1 Capi l l ar y Wat er Bar r i er
1. 3. 2 Degr ee of Compact i on
1. 3. 3 Har d Mat er i al s
1. 4 SUBMI TTALS
1. 5 DELI VERY, STORAGE, AND HANDLI NG
1. 6 REQUI REMENTS FOR OFF SI TE SOI L
1. 7 QUALI TY ASSURANCE
1. 7. 1 Per sonnel Requi r ement s
1. 7. 2 Ut i l i t i es
PART 2 PRODUCTS
2. 1 SOI L MATERI ALS
2. 1. 1 Sat i sf act or y Mat er i al s
2. 1. 2 Unsat i sf act or y Mat er i al s
2. 1. 3 Excavat ed On- Si t e Mat er i al s
2. 1. 3. 1 Sat i sf act or y " Fi l l Mat er i al "
2. 1. 3. 2 Cl ay
2. 1. 3. 3 On- si t e mat er i al f r om bel ow " 1994 Sur vey"
2. 1. 4 I mpor t ed Mat er i al
2. 1. 4. 1 St r uct ur e Backf i l l
2. 1. 4. 2 B Bor r ow
2. 2 ENVI RONMENTAL REQUI REMENTS FOR BORROW MATERI AL
2. 2. 1 Def i ni t i ons
2. 2. 1. 1 Sat i sf act or y Mat er i al s
2. 2. 1. 2 Unsat i sf act or y Mat er i al s
2. 2. 1. 3 I n- Si t u Bor r ow Mat er i al s
2. 2. 1. 4 St ockpi l ed Bor r ow Mat er i al s
2.