VAV and ERV Info.pdf

PDF 1 MB Posted

Attached to
Cordell Hull HVAC Replacement Federal contract opportunity
Solicitation number
W912P524Q0047
Issued by
Department of the Army Corps of Engineers Engineering District Nashville

About this file

This document is a solicitation for the purchase of one 10-ton HVAC unit and one 7.5-ton HVAC unit, as well as associated equipment, for the Cordell Hull facility in Carthage, Tennessee. The U.S. Army Corps of Engineers, Nashville District is issuing this firm fixed-price supply contract with a 60-calendar day completion date. The solicitation is a Total Small Business Set-Aside under NAICS code 333415, with award based on the lowest priced, responsive, and responsible offeror. Requested items include the HVAC units, a PC, controller, software, hardware, carbon dioxide detectors, energy recovery ventilators, temperature sensors/thermostats, and variable air volume controllers. Quotes are due by September 20, 2024 at 1:00 PM Central Time. A pre-quote site visit is scheduled for September 12, 2024. Delivery shall be coordinated at least 14 calendar days in advance and shall not occur on federal holidays.

View the file

Other files for this federal contract opportunity

Other files attached to Cordell Hull HVAC Replacement, newest first.
File Type Posted
RMO Drawing 1.pdf PDF
W912P524Q0047 0001 COR HVAC Solicitation Amendment.pdf PDF
RMO Drawing 2.pdf PDF
W912P524Q0047 0002 COR HVAC Solicitation Amendment.pdf PDF
RTU1.jpg JPG image
RTU2.jpg JPG image
W912P524Q0047 COR HVAC Solicitation.pdf PDF
US Citizen Pre_Bid or Site Visit Form JAN 2019 (2).pdf PDF
FN Pre_Bid or Site Visit Form JAN 2019 (2).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

524560-YIM-B-1109

If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or customer's expense.

Size of unit for proposed installation should be based on heat loss/heat gain calculation made according to the methods of Air Conditioning Contractors of America (ACCA).

This furnace is not to be used for temporary heating of buildings or structures under construction.

IACAUTIO]]

The Simplicity® control board used in this product will effectively operate the cooling system down to 0"F when-this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877-UPG-SERV for guidance.

Additional accessories may be needed for stable operation at temperatures below 30° F.

Simplictry• control board Filter access w/screw connector for T-stat Disconnect location

Filter drier (solid core) wiring and network connections (optional disconnect switch) (2" or 4" Filter Options)

Terminal block for

Second model nameplate inside hinged access panel maximum comfort

Compressor #2 access (high efficiency compressor w/crankcase heater)

...,,,1

'':it.

Base rails w/forklift slots (three sides) and lifting holes

Roof curbs in eight- and � fourteen-inch heights. Roof�' curbs for transitioning from York Sunline ™ footprint to the ZH Series footprints are also available (field installed accessory) door latch Side entry power and control wiring knockouts hannel Aluminum Tube minum Fin Condenser

Slide-out motor and blower assembly for easy adjustment and service blower motor VFD Location (optional)

Pewor ¥OAIOF FROIOF

T\•,<o slage gas heating to maintain warm, comfortable temperature

Intelligent control board for safe and efficient operationCompressor #1 access

(high-efficiency compressor w/crankcase heater)

Johnson Controls Unitary Products

34 1/2"(876) �

HANGER BRACKETS (HB)

LOCATION

NOTES:

OR ,,,....._

58"(1473} /

OR 5' ATT.

ORMOA

ALTERNATE BRACKET LOCATION

IF INTERFERENCE WITH

SDV CONTROLS OCCURS

35E° (911]�

• HANGER BRACKET ARE 12 GAUGE ZINC COATED STEEL.

• 4 PER UNIT, 2 PER ATTENUATOR.

• BRACKETS ARE SHIPPED LOOSE FOR FIELD INSTALLATION FOR

USE WITH THREADED HANGER RODS. (BY OTHERS)

• LAYOUT INDICATES SUGGESTED HANGER BRACKET LOCATIONS.

/'.... _ 2"(25]

/ ;;:< 1YP

3�"(911)

ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC ANO ROUNDED TO THE NEAREST MIWMETER.

PROJECT:

Cordell Hull Visitors Ctr- VAV

ENGINEER:

CUSTOMER:

SUBMITTAL DA TE: SPEC. SYMBOL:

@ Copyright E.H.PRICE LIMITED 2010

ACCESSORIES

HANGER BRACKETS (HB)

LOCATIONS

FOR SDV

ELECTRIC COIL

CONTROLS BOX

NEMA 1

1/4"(32)

I r--+--l-....,::::;;:--=:;;=-�

E

L_:-=-B�_J

M ULTI-POINT SENSOR

C/W GAUGE TAPS

UNIT OUTLET INLET CONTROL BOX

SIZE B C D E

4 4(102) 0 13(330)

5 8 (203) 5(127) 0 13(330)

6 12 (305) 6(152) 13(330)

10 (254)

7(178) 13(330)

8 8(203) 13(330)

14 (356) 12112 (318)

9(229) 13(330)

10 10(254) 13(330)

12 16 (406) 15 (381) 12(305) 19( 483)

14 20 (508) 17112 (445) 14(356) 19( 483)

16 24(610) 18 (457) 16(406) 19(483)

SEE CATALOGUE FOR DETAILED CFM RANGE AND HEATING CAPACITY.

** 6" DIAMETER DUCT WITH 4" OR 5" REDUCER.

� 6"(152) I-

STANDARD COIL FEATURES:

• AUTOMATIC RESET THERMAL CUTOUT

• MANUAL RESET THERMAL CUTOUT

• LOW WATT DENSITY ELEMENTS, HIGH GRADE

NICKEL-CHROME ALLOY

• MAGNETIC CONTACTORS

• AIR FLOW SWITCH

• 24VAC/50VAC CLASS 2 TRANSFORMER

• HINGED ACCESS DOOR

• SINGLE POINT ELECTRICAL CONNECTION

• REFER TO SUBMITTED CONTROL DIAGRAMS

FOR STANDARD CONTROL COMPONENTS

TO BE SUPPLIED.

OPTIONAL COIL FEATURES:

0 CONTROL CIRCUIT FUSES

Jii( DOOR INTERLOCK DISCONNECT SWITCH

D ELECTRONIC MODULATING CONTROLS(EMC)

D MERCURY CONTACTORS

D MAIN SUPPLY FUSES

NOTES:

1 ,. 0 PSG - Price Silent GuordlM CONTROLLER • INTERNAL INSULATION - FIBERGLASS 12 (13)THICK, MIN. 1.5# 1"C.. SCR CONTROLS □ SCR-DAT CONTROLSDENSITY, WHICH MEETS REQUIREMENTS OF NFPA 90A AND UL 181 . .r"'

• ZINC COATED STEEL 22GA. TERMINAL & 20 GA. HEATER, A O to 10 Vdc CONTROL SIGNAL MECHANICALLY SEALED AND G�SKETED, LEAK D 4 to 20 mA CONTROL SIGNAL

RESISTANT CONSTRUCTION .

OPTIONAL DUCT LINERS AND CONSTRUCTION:

• SEE NOTE

• RECTANGULAR DISCHARGE OPENINGS HAVE

SUP & DRIVE CLEAT DUCT CONNECTIONS. 0 FG75 D FG1 D AFPM D AFPM1 D CRWF

• CONTROL ASSEMBLY WILL BE SUPPLIED AS

ILLUSTRATED ON RIGHT HANO SIDE

O SM O SM1 D CRAF D CRAF1 D PM D PM1

UNLESS SPECIFIED OTHERWISE.

D F'F D ff1 D FF50 D FB D FB1 D WFPM

• DIGITAL CONTROLS SUPPLIED BY CONTROLS SUPPLY VOLT AGE:

CONTRACTOR. 0 120/1¢ D 480/30 (3 WIRE)

• FOR ACCESSORIES SEE SUBMITTAL DRAWINGS. D 208/10 (2 WIRE) O 600/30 (3 OR

• SCR CONTROLS OVER 25 AMPS 313 USE 19" ( 483) CONTROL BOX. D 208/30 (3 WIRE) 4 WIRE)

• ASSEMBLY ffi CERTIFIED TO UL1995 & CSA236. 0 240/11/J

);_ - • --�,;:C

,1,.<:UAJ.,,_

US

OPTIONS: A CONTROLS ENCLOSURE � 277 /11/J U

0 2090 OUTER CASING D 347 /lr/J

D RS - BOTTOM REMOVABLE SENSOR O 480/10 ·- - - - ----·-- =

ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER.

PROJECT: Cordell Hull Visitors Ctr.-VAV

ENGINEER: SDV5000

1-------------------------------1------1INTEGRAL ELECTRIC REHEAT

SIZE 4 TO 16 ASSEMBLY

DIGITAL CONTROLS

CUSTOMER:

SUBMITTAL DATE: SPEC. SYMBOL:

@ Copyright E.H.PRICE LIMITED 2010

RenewAire ERV Calculator

�--RenewAire --� V E N 1' I L A T I O N

Think Greener. Breath Better.

Unit Images

Model: HE2XINH

File details come from the government source that posted it. Updated .