Q and A_AH-64 Wrap Around Maintenance Stands Part II.pdf

PDF 104 KB Posted

Attached to
AH-64 Wrap-Around Maintenance Stands
Solicitation number
W912NW22Q0108
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W912NW22Q0108 AH-64 Wrap Around Maintenance Stands Q&As (Part II)

1. Regarding the drawings for these maintenance stands, will the contractor be required to produce drawings per a certain specification per CCAD, or can we produce drawings per our own specifications? This is in reference only to the drawings, not the design of the stand. Some of the other bases we have worked have drawings standards and specify font, line thicknesses, etc.

ANSWER: THE MANUFACTURER SHALL PRODUCE DRAWINGS PER THEIR OWN SPECIFICATIONS

AND STANDARDS. CCAD HAS NO OPINION REGARDING MANUFACTURE’S DRAWING STANDARDS

OR REQUIREMENTS.

2. In reference to the installation, CCAD requests one stand to be delivered to ensure stands fits, once approved the second stand shall be delivered. However, in the CLIN structure below, it shows 2 unit stands but 1 install. Is this correct?

CLIN structure:

CLIN 0001

Description: AH-64 Wrap Around Maintenance Stands

Unit of Measure: Each

Quantity: 2

Unit Price:

Extended Price:

CLIN 0002

Description: Set-up (assembly) and Training

Unit of Measure: Each

Quantity: 1

Unit Price:

Extended Price:

ANSWER: YES, THAT IS CORRECT.