USACE / NAVFAC / AFCEC / NASA UFGS- 08 11 16 ( May 2017) Change 2 - 11/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 08 11 16 ( August 2008)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS
Ref er ences ar e i n agr eement wi t h UMRL dat ed Apr i l 2019
SECTI ON TABLE OF CONTENTS
DI VI SI ON 08 - OPENI NGS
SECTI ON 08 11 16
ALUMI NUM DOORS AND FRAMES
05/17
PART 1 GENERAL
1. 1 REFERENCES
1. 2 PERFORMANCE REQUI REMENTS
1. 2. 1 St r uct ur al Cal cul at i ons
1. 2. 1. 1 Mi ni mum Ant i t er r or i sm Per f or mance
1. 2. 2 Wi nd Bor ne Debr i s
1. 2. 3 Ai r I nf i l t r at i on
1. 2. 4 Wat er Penet r at i on
1. 2. 5 Ther mal Tr ansmi t t ance, Sol ar Heat Gai n, Vi s i bl e Li ght
Transmittance
1. 2. 5. 1 U- Fact or
1. 2. 5. 2 Sol ar Heat Gai n Coef f i c i ent ( SHGC)
1. 2. 5. 3 Vi s i bl e Li ght Tr ansmi t t ance ( VLT)
1. 2. 5. 4 Door s wi t h Less t han 50 Per cent Gl azed Ar ea
1. 3 SUBMI TTALS
1. 4 DELI VERY, STORAGE, AND HANDLI NG
1. 5 QUALI TY CONTROL
1. 5. 1 Shop Dr awi ng
1. 5. 2 Fi ni sh Sampl es
1. 5. 3 Desi gn Anal ysi s
1. 5. 4 Test Repor t s
1. 5. 5 Oper at i on and Mai nt enance Dat a
1. 6 QUALI TY ASSURANCE
1. 6. 1 Engi neer Qual i f i cat i ons f or Bl ast Desi gn
PART 2 PRODUCTS
2. 1 DOORS AND FRAMES
2. 2 MATERI ALS
2. 2. 1 Anchor s
2. 2. 2 Weat her st r i ppi ng
2. 2. 3 Al umi num Al l oy f or Door s and Fr ames
2. 2. 4 Fast ener s
2. 2. 5 St r uct ur al St eel
SECTI ON 08 11 16 Page 1
2. 2. 6 Al umi num Pai nt
2. 3 FABRI CATI ON
2. 3. 1 Al umi num Fr ames
2. 3. 2 Al umi num Door s
2. 3. 2. 1 Ful l Gl azed St i l e and Rai l Door s
2. 3. 2. 2 Fl ush Door s
2. 3. 3 Wel di ng and Fast eni ng
2. 3. 4 Weat her st r i ppi ng
2. 3. 5 Anchor s
2. 3. 6 Pr ovi s i ons f or Har dwar e
2. 3. 7 Pr ovi s i ons f or Gl azi ng
2. 3. 8 Fi ni shes
2. 3. 8. 1 Anodi c Coat i ng
2. 3. 8. 2 Or gani c Coat i ng
PART 3 EXECUTI ON
3. 1 I NSTALLATI ON
3. 2 PROTECTI ON FROM DI SSI MI LAR MATERI ALS
3. 2. 1 Di ss i mi l ar Met al s
3. 2. 1. 1 Pr ot ect i on
3. 2. 2 Dr ai nage f r om Di ssi mi l ar Met al s
3. 2. 3 Masonr y and Concr et e
3. 2. 4 Wood or Ot her Absor pt i ve Mat er i al s
3. 3 SEALI NG AROUND ASSEMBLI ES
3. 4 CLEANI NG
3. 5 PROTECTI ON
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 08 11 16 Page 2
USACE / NAVFAC / AFCEC / NASA UFGS- 08 11 16 ( May 2017) Change 2 - 11/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 08 11 16 ( August 2008)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS
Ref er ences ar e i n agr eement wi t h UMRL dat ed Apr i l 2019
SECTI ON 08 11 16
ALUMI NUM DOORS AND FRAMES
05/17
NOTE: Thi s gui de speci f i cat i on cover s al umi num door s and f r ames i nt ended f or use pr i mar i l y as mai n ent r ance and vest i bul e door s, and f or pr omi nent i nt er i or door s f r om l obbi es and s i mi l ar spaces i n bui l di ngs of publ i c access wher e appear ance i s important.
Adher e t o UFC 1- 300- 02 Uni f i ed Faci l i t i es Gui de Speci f i cat i ons ( UFGS) For mat St andar d when edi t i ng t hi s gui de speci f i cat i on or pr epar i ng new pr oj ect speci f i cat i on sect i ons. Edi t t hi s gui de speci f i cat i on f or pr oj ect speci f i c r equi r ement s by addi ng, del et i ng, or r evi s i ng t ext . For br acket ed i t ems, choose appl i cabl e i t em( s) or i nser t appr opr i at e i nf or mat i on.
Remove i nf or mat i on and r equi r ement s not r equi r ed i n r espect i ve pr oj ect , whet her or not br acket s ar e present.
Coor di nat e wi t h or i ncor por at e i nt o t hi s gui de speci f i cat i on Al umi num- Fr amed Ent r ances and St or ef r ont s, Cur t ai n Wal l and Gl azed Assembl i es ( f r ames) , St eel / Al umi num Door s and Fr ames and Gl azi ng. I nser t t he appr opr i at e assembl y i n t he bl anks as appl i cabl e. Choose appr pr i at e damage l evel / l evel of pr ot ect i on f or bui l di ng occupancy as def i ned i n UFC 4- 010- 01 ( Tabl e 2- 1) .
Comment s, suggest i ons and r ecommended changes f or t hi s gui de speci f i cat i on ar e wel come and shoul d be submi t t ed as a Cr i t er i a Change Request ( CCR) .
NOTE: On t he dr awi ngs, show:
1. Si ze and t ypes of door openi ngs; t hi cknesses, swi ngs and t r avel of door s; whet her f l ush, panel ed, gl azed, or l ouver ed; wi dt h of st i l es and r ai l s , and
SECTI ON 08 11 16 Page 3 power t r ansf er component s as appl i cabl e.
2. El evat i ons of each door and f r ame t ype, at 1: 50 1/ 4 i nch scal e
3. Det ai l s of head, j amb, s i l l , mul l i ons, and t r ansom sect i ons; key sect i ons t o door f r ame pl ans and el evat i ons. I ndi cat e t ype and spaci ng of anchors.
4. I ndi cat e t hi ckness of gl azi ng r equi r ed and cr oss r ef er ence t o Sect i on 08 81 00 GLAZI NG.
5. Det ai l s of weat her st r i ppi ng f or ext er i or door s.
6. Amount of f r ee ar ea f or l ouver s.
7. A uni que number f or each door openi ng on door schedule.
PART 1 GENERAL
1. 1 REFERENCES
NOTE: Thi s par agr aph i s used t o l i s t t he publ i cat i ons c i t ed i n t he t ext of t he gui de speci f i cat i on. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y and l i s t ed i n t hi s par agr aph by or gani zat i on, desi gnat i on, dat e, and t i t l e.
Use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e when you add a Ref er ence I dent i f i er ( RI D) out s i de of t he Sect i on' s Ref er ence Ar t i c l e t o aut omat i cal l y pl ace t he r ef er ence i n t he Ref er ence Ar t i c l e. Al so use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e t o updat e t he i ssue dat es.
Ref er ences not used i n t he t ext wi l l aut omat i cal l y be del et ed f r om t hi s sect i on of t he pr oj ect speci f i cat i on when you choose t o r econci l e r ef er ences i n t he publ i sh pr i nt pr ocess.
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
ALUMI NUM ASSOCI ATI ON ( AA)
AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes
AMERI CAN ARCHI TECTURAL MANUFACTURERS ASSOCI ATI ON ( AAMA)
AAMA 2603 ( 2017a) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test
SECTI ON 08 11 16 Page 4
Pr ocedur es f or Pi gment ed Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s
AAMA 2604 ( 2017a) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Hi gh Per f or mance Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s
AMERI CAN SOCI ETY OF HEATI NG, REFRI GERATI NG AND AI R- CONDI TI ONI NG
ENGI NEERS ( ASHRAE)
ASHRAE 90. 1 - I P ( 2013) Ener gy St andar d f or Bui l di ngs Except Low- Ri se Resi dent i al Bui l di ngs
ASHRAE 90. 1 - SI ( 2013) Ener gy St andar d f or Bui l di ngs Except Low- Ri se Resi dent i al Bui l di ngs
ASTM I NTERNATI ONAL ( ASTM)
ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel
ASTM B209 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e
ASTM B209M ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e ( Met r i c)
ASTM B221 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes
ASTM B221M ( 2013) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes ( Met r i c)
ASTM E1886 ( 2013a) St andar d Test Met hod f or Per f or mance of Ext er i or Wi ndows, Cur t ai n Wal l s, Door s, and I mpact Pr ot ect i ve Syst ems I mpact ed by Mi ssi l e( s) and Exposed t o Cycl i c Pr essur e Di f f er ent i al s
ASTM E1996 ( 2017) St andar d Speci f i cat i on f or Per f or mance of Ext er i or Wi ndows, Cur t ai n Wal l s, Door s, and I mpact Pr ot ect i ve Syst ems I mpact ed by Wi ndbor ne Debr i s i n Hurricanes
ASTM E283 ( 2004; R 2012) Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men
ASTM E331 ( 2000; R 2016) St andar d Test Met hod f or Wat er Penet r at i on of Ext er i or Wi ndows, Skyl i ght s, Door s, and Cur t ai n Wal l s by Uni f or m St at i c Ai r Pr essur e Di f f er ence
ASTM F1642/ F1642M ( 2017) St andar d Test Met hod f or Gl azi ng
SECTI ON 08 11 16 Page 5 and Gl azi ng Syst ems Subj ect t o Ai r bl ast Loadings
ASTM F1643 ( 2012) St andar d Test Met hods f or Det ent i on Sl i di ng Door Locki ng Devi ce Assembl y
ASTM F2247 ( 2011; R 2017) St andar d Test Met hod f or Met al Door s Used i n Bl ast Resi st ant Appl i cat i ons ( Equi val ent St at i c Load Method)
ASTM F2927 ( 2012) St andar d Test Met hod f or Door Syst ems Subj ect t o Ai r bl ast Loadi ngs
NATI ONAL FENESTRATI ON RATI NG COUNCI L ( NFRC)
NFRC 100 ( 2014) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct U- Fact or s
NFRC 200 ( 2014) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct Sol ar Heat Gai n Coef f i c i ent and Vi s i bl e Tr ansmi t t ance at Nor mal I nci dence
1. 2 PERFORMANCE REQUI REMENTS
1. 2. 1 St r uct ur al Cal cul at i ons
NOTE: Dynami c anal ysi s i s pr ef er r ed because i t t ypi cal l y y i el ds a mor e appr opr i at e and economi cal / ef f i c i ent desi gn. UFC 4- 010- 01 al so i ndi cat es t hat f or vest i bul es, f oyer s, or s i mi l ar ent r y conf i gur at i ons i nt o i nhabi t ed ar eas wher e t her e ar e i nner and out er door s t he vest i bul es, f oyer s, or s i mi l ar ent r i es ar e consi der ed not t o be r out i nel y occupi ed spaces. Speci f y i nner door s and gl azi ng capabl e of mi t i gat i ng any hazar ds r esul t i ng f r om t he encl osed vest i bul e or f oyer out er door s and gl azi ng f ai l ur e i n r esponse t o t he desi gn bl ast event . Thi s i s t o account f or t he f act t hat at l evel s of pr ot ect i on r equi r ed i n t hese st andar ds t he out er door s and gl azi ng may f ai l , whi ch woul d subj ect t he i nner door s and gl azi ng t o s i gni f i cant bl ast l oads. To pr ovi de t hat debr i s r esi st ance, t he i nner door s, s i del i ght s, and t r ansoms must meet t he wi ndbor ne debr i s r esi st ance r equi r ement s of ASTM E1996 ( mi ssi l es A and D i n Tabl e 2) . For door assembl i es i nt o vest i bul es, f oyer s, and si mi l ar ent r y conf i gur at i ons i nt o i nhabi t ed ar eas use t he br acket ed i t em " Wi nd- Bor ne Debr i s" bel ow.
1. 2. 1. 1 Mi ni mum Ant i t er r or i sm Per f or mance
Pr ovi de door s meet i ng t he mi ni mum ant i t er r or i sm per f or mance as speci f i ed i n t he par agr aphs bel ow.
[ a. Dynami c Desi gn Anal ysi s Met hod
SECTI ON 08 11 16 Page 6
NOTE: Use t he f ol l owi ng br acket ed par agr aph i f desi gni ng t he door assembl y usi ng dynami c anal ysi s.
As an al t er nat i ve t o t he st at i c equi val ent l oad desi gn appr oach descr i bed above, gl azed openi ng f r ami ng member s, anchor s, and gl azi ng may be desi gned usi ng a dynami c anal ysi s t o pr ove t he gl azed openi ng syst em wi l l pr ovi de per f or mance equi val ent t o or bet t er t han a ver y l ow hazar d r at i ng i n accor dance wi t h ASTM F1642/ F1642M associ at ed wi t h t he appl i cabl e l ow l evel of pr ot ect i on f or t he pr oj ect .
][ [ a] [ b] . St andar d Ai r bl ast Test Met hod
NOTE: Use t he f ol l owi ng br acket ed par agr aph i f t est i ng t he door assembl y i n accor dance wi t h ASTM F2927 St andar d Test Met hod f or Door Syst ems Subj ect t o Ai r bl ast Loadi ngs.
Test i ng i n accor dance wi t h ASTM F2927 may be by shock t ube or ar ena t est . Per f or m t he t est on t he ent i r e pr oposed door assembl y, whi ch must i ncl ude, but not be l i mi t ed t o, t he gl azi ng, i t s f r ami ng/ suppor t syst em, oper at i ng devi ces, and al l anchor age devi ces. I nst al l door syst em anchor age t hat r epl i cat es t he met hod of i nst al l at i on t o be used f or t he pr oj ect . Ut i l i ze t he f ast ener s and anchor age met hods used t o at t ach t he t est ed door assembl y t hat ar e r epr esent at i ve of t he act ual door i nst al l at i on. Demonst r at e by cal cul at i on any devi at i ons i n act ual i nst al l at i on of t he connect i ons or t he connect ed el ement s f r om t hose t est ed t o pr ovi de t he damage l evel as i ndi cat ed bel ow.
The mi ni mum ai r bl ast l oadi ng par amet er s f or t he t est must be as f ol l ows: peak posi t i ve pr essur e of [ _____] k i l opascal s ( kPa) [ _____] pounds per squar e i nch ( psi ) ; and peak posi t i ve phase i mpul se of [ _____] k i l opascal - mi l l i second ( kPa- msec) [ _____] pounds per squar e i nch - mi l l i second ( psi - msec) .
The accept ance cr i t er i a f or t he pr oposed door syst ems, as det er mi ned by t he damage l evel / door r esponse damage cr i t er i a of [ ASTM F2247][ ASTM F2927] , wi l l pr ovi de a per f or mance equi val ent t o or bet t er t han a cat egor y [ I V] ; [ I I I ] ; [ _____] door damage l evel r at i ng. [ Door gl azi ng per f or mance must be equi val ent t o or bet t er t han [ H3- Ver y Low] [ H4- Low] hazar d r at i ng i n accor dance wi t h ASTM F1642/ F1642M.]
] [ 1. 2. 2 Wi nd Bor ne Debr i s
NOTE: I n pr oj ect s l ocat ed i n wi ndbor ne debr i s r egi ons, desi gn per f or mance r equi r ement s may exceed bl ast mi t i gat i on r equi r ement s. Sel ect t he most st r i ngent r equi r ement based on geogr aphi c r egi on and AT st andof f .
Pr ovi de i mpact r esi st ant door [ _____] assembl i es meet i ng t he Wi ndbor ne- Debr i s- I mpact Resi st ant Per f or mance r equi r ement s of ASTM E1996 and ASTM E1886 as f ol l ows:
SECTI ON 08 11 16 Page 7
( 1) Pass mi ssi l e- i mpact t est s when t est ed accor di ng t o ASTM E1886 and meet i ng per f or mance r equi r ement s accor di ng t o ASTM E1996 f or mi ssi l es A and D i n Tabl e 2.
] 1. 2. 3 Ai r I nf i l t r at i on
When t est ed i n accor dance wi t h ASTM E283, ai r i nf i l t r at i on per door l eaf cannot exceed 2. 83 by 10- 4 cms per squar e met er 0. 6 cubi c f eet per mi nut e per squar e f oot of f i xed ar ea at a t est pr essur e of 0. 30 kPa 6. 24 pounds per squar e f oot .
1. 2. 4 Wat er Penet r at i on
When t est ed i n accor dance wi t h ASTM E331, t her e can be no wat er penet r at i on at a pr essur e of 0. 14 kPa 2. 86 pounds per squar e f oot of f i xed ar ea.
1. 2. 5 Ther mal Tr ansmi t t ance, Sol ar Heat Gai n, Vi s i bl e Li ght Tr ansmi t t ance
NOTE: Coor di nat e compl i ance wi t h ASHRAE 90. 1 f or " whol e- wi ndow" ( or over al l assembl y) t her mal t r ansmi t t ance val ue ( U- f act or ) , Sol ar Heat Gai n Coef f i c i ent ( SHGC) and vi s i bl e l i ght t r ansmi t t ance ( VT) f or f i el d assembl ed f enest r at i on. Ent er r equi r ed val ues i n br acket s. Cer t i f i cat i on of syst em i s by means of NFRC val i dat ed Pr oj ect Label Cer t i f i cat es f or al l f i el d assembl ed f enest r at i on.
Pr ovi de pr oduct s bear i ng NFRC Pr oj ect Label Cer t i f i cat es f or Fenest r at i on ver i f y i ng compl i ance wi t h r equi r ement s f or each assembl y i ndi cat ed. An NFRC Bi d Repor t , or appr oved equal , f or f i el d assembl ed ext er i or door s may be submi t t ed i n l i eu of Pr oj ect Label Cer t i f i cat es f or Fenest r at i on i f such r epor t s ar e cr eat ed i n accor dance wi t h NFRC CAMP pr ocedur es and ar e pr ovi ded by t he manuf act ur er . Such al t er nat e r epor t s may be submi t t ed wi t h shop dr awi ngs, however , NFRC val i dat ed Pr oj ect Label Cer t i f i cat es f or Fenest r at i on ar e r equi r ed as a Cl oseout Submi t t al . Cont act NFRC f or i nf or mat i on on NFRC 100 and NFRC 200 Compl i ance and Moni t or i ng Pr ogr am ( CAMP) r at i ng r equi r ement s:
http://www.nfrc.org/industry/certification/compliance-and-monitoring-program-camp/
1. 2. 5. 1 U-Factor
Pr ovi de ext er i or gl azed assembl i es, i ncl udi ng al umi num ent r ances door s wi t h gr eat er t han 50 per cent gl azed ar ea, cer t i f i ed by t he NFRC as havi ng a whol e wi ndow U- f act or of [ _____] or l ess as det er mi ned i n accor dance wi t h ASHRAE 90. 1 - SI ASHRAE 90. 1 - I P and as ver i f i ed i n accor dance wi t h
NFRC 100.
1. 2. 5. 2 Sol ar Heat Gai n Coef f i c i ent ( SHGC)
Pr ovi de ext er i or gl azed assembl i es, i ncl udi ng al umi num ent r ances door s wi t h gr eat er t han 50 per cent gl azed ar ea, cer t i f i ed by t he Nat i onal Fenest r at i on Rat i ng Counci l wi t h a whol e wi ndow SHGC of [ _____] or l ess as det er mi ned i n accor dance wi t h ASHRAE 90. 1 - SI ASHRAE 90. 1 - I P and as ver i f i ed i n accor dance wi t h NFRC 200.
SECTI ON 08 11 16 Page 8
1. 2. 5. 3 Vi s i bl e Li ght Tr ansmi t t ance ( VLT)
Pr ovi de ext er i or gl azed assembl i es, i ncl udi ng al umi num ent r ances door s wi t h gr eat er t han 50 per cent gl azed ar ea, cer t i f i ed by t he NFRC wi t h a whol e wi ndow VLT of [ _____] or gr eat er as det er mi ned i n accor dance wi t h ASHRAE 90. 1 - SI ASHRAE 90. 1 - I P and as ver i f i ed i n accor dance wi t h
NFRC 200.
[ 1. 2. 5. 4 Door s wi t h Less t han 50 Per cent Gl azed Ar ea
For ext er i or al umi num ent r ances door s wi t h l ess t han 50 per cent gl azed ar ea, t he gl azed ar ea i s consi der ed t he f enest r at i on ar ea and must be cer t i f i ed by t he Nat i onal Fenest r at i on Rat i ng Counci l wi t h a whol e wi ndow U- Fact or , SHGC and VLT as r equi r ed above.
] 1. 3 SUBMITTALS
NOTE: Revi ew Submi t t al Descr i pt i on ( SD) def i ni t i ons i n Sect i on 01 33 00 SUBMI TTAL PROCEDURES and edi t t he f ol l owi ng l i s t t o r ef l ect onl y t he submi t t al s r equi r ed f or t he pr oj ect .
The Gui de Speci f i cat i on t echni cal edi t or s have desi gnat ed t hose i t ems t hat r equi r e Gover nment appr oval , due t o t hei r compl exi t y or cr i t i cal i t y , wi t h a " G. " Gener al l y, ot her submi t t al i t ems can be r evi ewed by t he Cont r act or ' s Qual i t y Cont r ol Syst em. Onl y add a " G" t o an i t em, i f t he submi t t al i s suf f i c i ent l y i mpor t ant or compl ex i n cont ext of t he pr oj ect .
For submi t t al s r equi r i ng Gover nment appr oval on Ar my pr oj ect s, a code of up t o t hr ee char act er s wi t hi n t he submi t t al t ags may be used f ol l owi ng t he " G" desi gnat i on t o i ndi cat e t he appr ovi ng aut hor i t y.
Codes f or Ar my pr oj ect s usi ng t he Resi dent Management Syst em ( RMS) ar e: " AE" f or Ar chi t ect - Engi neer ; " DO" f or Di st r i c t Of f i ce ( Engi neer i ng Di v i s i on or ot her or gani zat i on i n t he Di st r i c t Of f i ce) ; " AO" f or Ar ea Of f i ce; " RO" f or Resi dent Of f i ce; and " PO" f or Pr oj ect Of f i ce. Codes f ol l owi ng t he " G" t ypi cal l y ar e not used f or Navy, Ai r For ce, and NASA pr oj ect s.
The " S" f ol l owi ng a submi t t al i t em i ndi cat es t hat t he submi t t al i s r equi r ed f or t he Sust ai nabi l i t y eNot ebook t o f ul f i l l f eder al l y mandat ed sust ai nabl e r equi r ement s i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Locat e t he " S" submi t t al under t he SD number t hat best descr i bes t he submi t t al i t em.
Choose t he f i r st br acket ed i t em f or Navy, Ai r For ce and NASA pr oj ect s, or choose t he second br acket ed i t em f or Ar my pr oj ect s.
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
SECTI ON 08 11 16 Page 9 submi t t al s not havi ng a " G" desi gnat i on ar e [ f or Cont r act or Qual i t y Cont r ol appr oval . ] [ f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . ] Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on
01 33 00 SUBMI TTAL PROCEDURES:
SD- 02 Shop Dr awi ngs
For Each Type of Door and Fr ame Assembl y; G[ , [ _____] ]
SD- 03 Pr oduct Dat a
For Each Type of Door and Fr ame Assembl y; G[ , [ _____] ]
Recycl ed Cont ent of Al umi num Mat er i al ; S
SD- 04 Sampl es
Fi ni sh Sampl es; G[ , [ _____] ]
SD- 05 Desi gn Dat a
[ Desi gn Anal ysi s; G[ , [ _____] ]
] St r uct ur al Cal cul at i ons f or Def l ect i on and Ant i t er r or i sm; G[, SD- 06 Test Repor t s
Ai r I nf i l t r at i on; G[ , [ _____] ]
Wat er Penet r at i on; G[ , [ _____] ]
[ St andar d Ai r bl ast ; G[ , [ _____] ]
] SD- 07 Cer t i f i cat es
NFRC Pr oj ect Label Cer t i f i cat es f or Fenest r at i on; G[ , [ _____] ]
SD- 08 Manuf act ur er ' s I nst r uct i ons
I nst al l at i on of Each Type of Door and Fr ame Assembl y; G[ , [ _____] ]
SD- 10 Oper at i on and Mai nt enance Dat a
Adj ust ment s, Cl eani ng, and Mai nt enance; G[ , [ _____] ]
SD- 11 Cl oseout Submi t t al s
NFRC Pr oj ect Label Cer t i f i cat es f or Fenest r at i on; G[ , [ _____] ]
1. 4 DELI VERY, STORAGE, AND HANDLI NG
I nspect mat er i al s del i ver ed t o t he s i t e f or damage. Unl oad and st or e wi t h mi ni mum handl i ng. Pr ovi de st or age space i n dr y l ocat i on wi t h adequat e vent i l at i on, f r ee f r om dust or wat er , and easi l y accessi bl e f or i nspect i on and handl i ng. St ack mat er i al s on non- absor pt i ve st r i ps or wood pl at f or ms.
SECTI ON 08 11 16 Page 10
Do not cover door s and f r ames wi t h t ar ps, pol yet hyl ene f i l m, or s i mi l ar cover i ngs. Pr ot ect f i ni shed sur f aces dur i ng shi ppi ng and handl i ng usi ng manuf act ur er ' s st andar d met hod. Do not appl y coat i ngs or l acquer s t o sur f aces t o whi ch caul k i ng and gl azi ng compounds must adher e.
1. 5 QUALI TY CONTROL
1. 5. 1 Shop Dr awi ng
I ndi cat e el evat i ons and sect i ons f or each t ype of door and f r ame assembl y.
Show si zes and det ai l s of each assembl y, f r ame const r uct i on, [ subf r ame at t achment , ] t hi ckness and gages of met al , det ai l s of door and f r ame const r uct i on, pr oposed met hod( s) of anchor age, gl azi ng det ai l s , pr ovi s i ons f or an l ocat i on of har dwar e, [ mul l i on det ai l s , ] met hod and mat er i al s f or f l ashi ng and weat her st r i ppi ng, mi scel l aneous t r i m, i nst al l at i on det ai l s , and ot her r el at ed i t ems necessar y f or a compl et e r epr esent at i on of al l component s. A qual i f i ed bl ast engi neer must per f or m t est i ng or cal cul at i ons f or door syst em desi gn r esi st ance t o speci f i ed bl ast l oads.
1. 5. 2 Fi ni sh Sampl es
Submi t t wo col or char t s and t wo f i ni sh sampl e chi ps f r om manuf act ur er ' s st andar d col or and f i ni sh opt i ons f or each t ype of f i ni sh i ndi cat ed.
[ 1. 5. 3 Desi gn Anal ysi s
Submi t desi gn anal ysi s wi t h cal cul at i ons showi ng t hat t he desi gn of each di f f er ent s i ze and t ype of door uni t [ _____] and i t s anchor age t o t he st r uct ur e meet s t he mi ni mum ant i t er r or i sm st andar ds r equi r ed by par agr aph MI NI MUM ANTI TERRORI SM PERFORMANCE[ , unl ess conf or mance i s demonst r at ed by st andar d bl ast t est r esul t s] . Cal cul at i ons ver i f y i ng t he per f or mance of each door [ _____] pr oposed f or use, under t he gi ven l oads, must be pr epar ed and si gned by a r egi st er ed Pr of essi onal Engi neer . The door [ _____] component s and anchor age devi ces t o t he st r uct ur e, as det er mi ned by t he desi gn anal ysi s, must be r ef l ect ed i n t he shop dr awi ngs.
] 1. 5. 4 Test Repor t s
Test door assembl y [ i ncl udi ng gl azi ng ] f or eval uat i on of hazar ds gener at ed f r om ai r bl ast l oadi ng i n accor dance wi t h [ ASTM F2247][ ASTM F2927] by an i ndependent t est i ng agency r egul ar l y engaged i n bl ast t est i ng. Thi s t est met hod and t he r esul t i ng dat a ar e val i d f or t he door s i ze t est ed and smal l er door s of i dent i cal const r uct i on.
NOTE: Use t he f ol l owi ng br acket ed par agr aph i f desi gni ng t he door assembl y usi ng dynami c anal ysi s.
[ Desi gn Door assembl y ( i ncl udi ng gl azi ng) usi ng a dynami c anal ysi s t o pr ove t he per f or mance equi val ent t o or bet t er t han a cat egor y [ I V] ; [ I I I ] ; [ _____] door damage l evel i n accor dance wi t h ASTM F2927 f or t he peak posi t i ve pr essur e of [ _____] k i l opascal s ( kPa) [ _____] pounds per squar e i nch ( psi ) ;
and peak posi t i ve phase i mpul se of [ _____] k i l opascal - mi l l i second ( kPa- msec) [ _____] pounds per squar e i nch - mi l l i second ( psi - msec) . Use a t r i angul ar bl ast l oad usi ng t he appl i cabl e pr essur e and i mpul se i dent i f i ed above.
NOTE: Use t he f ol l owi ng br acket ed par agr aph i f
SECTI ON 08 11 16 Page 11 t est i ng t he door assembl y i n accor dance wi t h ASTM F2927 St andar d Test Met hod f or Door Syst ems Subj ect t o Ai r bl ast Loadi ngs.
][ For mi ni mum Ant i t er r or i sm door s [ _____] , i n l i eu of a Desi gn Anal ysi s, submi t r esul t s of st andar d bl ast t est i ng, i ncl uded i n a t est r epor t , pr ovi di ng i nf or mat i on i n accor dance wi t h [ ASTM F2247][ ASTM F2927] , as pr epar ed by t he i ndependent t est i ng agency per f or mi ng t he t est . The t est r esul t s must demonst r at e t he abi l i t y of each door [ _____] pr oposed f or use t o wi t hst and t he bl ast l oadi ng par amet er s and achi eve t he damage [ hazar d] l evel r at i ng speci f i ed i n par agr aph TESTI NG.
][ Test i ng i n accor dance wi t h ASTM F2927 may be by shock t ube or ar ena t est .
Per f or m t he t est on t he ent i r e pr oposed door assembl y, whi ch must i ncl ude, but not be l i mi t ed t o, t he gl azi ng, i t s f r ami ng/ suppor t syst em, oper at i ng devi ces, and al l anchor age devi ces. I nst al l door syst em anchor age t hat r epl i cat es t he met hod of i nst al l at i on t o be used f or t he pr oj ect . Ut i l i ze t he f ast ener s and anchor age met hods used t o at t ach t he t est ed door assembl y t hat ar e r epr esent at i ve of t he act ual door i nst al l at i on. Demonst r at e by cal cul at i on any devi at i ons i n act ual i nst al l at i on of t he connect i ons or t he connect ed el ement s f r om t hose t est ed t o pr ovi de t he damage l evel as i ndi cat ed bel ow.
The mi ni mum ai r bl ast l oadi ng par amet er s f or t he t est must be as f ol l ows:
peak posi t i ve pr essur e of [ _____] k i l opascal s ( kPa) [ _____] pounds per squar e i nch ( psi ) ; and peak posi t i ve phase i mpul se of [ _____] k i l opascal - mi l l i second ( kPa- msec) [ _____] pounds per squar e i nch -mi l l i second ( psi - msec) .
] The accept ance cr i t er i a f or t he pr oposed door syst ems, as det er mi ned by t he damage l evel / door r esponse damage cr i t er i al of [ ASTM F2247][ ASTM F2927], wi l l pr ovi de a per f or mance equi val ent t o or bet t er t han a cat egor y [ I V] ;
[ I I I ] ; [ _____] door damage l evel r at i ng. [ Door gl azi ng per f or mance must be equi val ent t o or bet t er t han [ H3 - Ver y l ow] [ H4 - Low] hazar d r at i ng i n accor dance wi t h ASTM F1643.]
1. 5. 5 Oper at i on and Mai nt enance Dat a
Submi t det ai l ed i nst r uct i ons f or i nst al l at i on, adj ust ment s, c l eani ng, and mai nt enance of each t ype of assembl y i ndi cat ed.
1. 6 QUALI TY ASSURANCE
1. 6. 1 Engi neer Qual i f i cat i ons f or Bl ast Desi gn
Al l bl ast desi gn cal cul at i ons must be per f or med by or under t he di r ect super vi s i on of a r egi st er ed engi neer wi t h a mi ni mum of 5 year s ' exper i ence per f or mi ng bl ast desi gn. The engi neer i ng f i r m per f or mi ng t he bl ast desi gn must be abl e t o demonst r at e exper i ence on s i mi l ar s i ze pr oj ect s usi ng s i mi l ar desi gn met hods t o meet t he r equi r ement s out l i ned i n t hi s specification.
PART 2 PRODUCTS
2. 1 DOORS AND FRAMES
Pr ovi de swi ng- t ype al umi num door s and f r ames of s i ze, desi gn, and l ocat i on i ndi cat ed. Pr ovi de door s compl et e wi t h f r ames, f r ami ng member s[ , SECTI ON 08 11 16 Page 12 subf r ames] [ , t r ansoms] [ , adj oi ni ng s i de l i t es] , t r i m, and accessor i es. [ Coor di nat e s i de l i t es, wi ndow wal l s, adj acent cur t ai nwal l wi t h Sect i on 08 41 13 ALUMI NUM- FRAMED ENTRANCES AND STOREFRONTS] [ and Sect i on 08 44 00
CURTAI N WALL AND GLAZED ASSEMBLI ES. ]
2. 2 MATERIALS
2. 2. 1 Anchors
St ai nl ess st eel [ or st eel wi t h hot - di pped gal vani zed f i ni sh] .
2. 2. 2 Weatherstripping
Cont i nuous wool pi l e, s i l i cone t r eat ed, or t ype r ecommended by door manufacturer.
2. 2. 3 Al umi num Al l oy f or Door s and Fr ames
ASTM B221M, ASTM B221, Al l oy 6063- T5 f or ext r usi ons. ASTM B209M, ASTM B209, al l oy and t emper best sui t ed f or al umi num sheet s and st r i ps. Pr ovi de al umi num mat er i al s t hat i ncl ude a mi ni mum of 30 per cent r ecycl ed cont ent .
Pr ovi de dat a i ndi cat i ng per cent age of r ecycl ed cont ent of al umi num mat er i al .
2. 2. 4 Fasteners
Har d al umi num or st ai nl ess st eel .
2. 2. 5 St r uct ur al St eel
ASTM A36/ A36M.
2. 2. 6 Al umi num Pai nt
Al umi num door manuf act ur er ' s st andar d al umi num pai nt .
2. 3 FABRICATION
2. 3. 1 Al umi num Fr ames
Ext r uded al umi num shapes wi t h cont our s appr oxi mat el y as i ndi cat ed. Pr ovi de r emovabl e gl ass st ops and gl azi ng beads f or f r ames accommodat i ng f i xed gl ass. Use count er sunk st ai nl ess st eel Phi l l i ps scr ews f or exposed f ast eni ngs, and space not mor e t han 300 mm 12 i nches on cent er . Mi l l j oi nt s i n f r ame member s t o a hai r l i ne f i t , r ei nf or ce, and secur e mechanically.
2. 3. 2 Al umi num Door s
Of t ype, s i ze, and desi gn i ndi cat ed and mi ni mum 45 mm 1- 3/ 4 i nch t hi ck.
mi ni mum wal l t hi ckness, 3 mm 0. 125 i nch, except beads and t r i m, 1. 25 mm
0. 050 i nch. Door s i zes shown ar e nomi nal ; i ncl ude st andar d c l ear ances as f ol l ows: 2. 5 mm 0. 093 i nch at hi nge and l ock st i l es, 3 mm 0. 125 i nch bet ween meet i ng st i l es, 3 mm 0. 125 i nch at t op r ai l s , 5 mm 0. 187 i nch bet ween bot t om and t hr eshol d, and 17 mm 0. 687 i nch bet ween bot t om and f l oor . [ Pr ovi de bevel s i ngl e- act i ng door s 2 or 3 mm 0. 063 or 0. 125 i nch at l ock, hi nge, and meet i ng st i l e edges. ] [ Pr ovi de doubl e- act i ng door s r ounded edges at hi nge st i l e, l ock st i l e, and meet i ng st i l e edges. ]
SECTI ON 08 11 16 Page 13
2. 3. 2. 1 Ful l Gl azed St i l e and Rai l Door s
Pr ovi de door s wi t h [ nar r ow] [ medi um] [ wi de] st i l es and r ai l s as i ndi cat ed.
Fabr i cat e f r om ext r uded al umi num hol l ow seaml ess t ubes or f r om a combi nat i on of open- shaped member s i nt er l ocked or wel ded t oget her . Fast en t op and bot t om r ai l t oget her by means of wel di ng or by 10 or 13 mm 3/ 8 or 1/ 2 i nch di amet er cadmi um- pl at ed t ensi oned st eel t i e r ods. Pr ovi de an adj ust abl e mechani sm of j ack scr ews or ot her met hods i n t he t op r ai l t o al l ow f or mi nor c l ear ance adj ust ment s af t er i nst al l at i on.
2. 3. 2. 2 Fl ush Door s
NOTE: The opt i onal t ypes of door const r uct i on may not be sui t abl e f or use i n al l f aci l i t i es. Del et e any opt i on l i s t ed not consi der ed desi r abl e f or a par t i cul ar usage or f or use i n a par t i cul ar f aci l i t y .
Use f aci ng sheet s wi t h[ a ver t i cal r i bbed] [ an embossed] [ or ] [ a pl ai n smoot h] sur f ace. Use one of t he f ol l owi ng const r uct i ons:
a. A phenol i c r esi n- i mpr egnat ed kr af t paper honeycomb cor e, sur r ounded at edges and ar ound gl ass and l ouver ed ar eas wi t h ext r uded al umi num shapes. Pr ovi de cor es wi t h a mi ni mum i mpr egnat i on of 18 per cent r esi n cont ent . Pr ovi de sheet al umi num door f aci ngs mi ni mum 0. 8 mm 0. 032 i nch t hi ck l ami nat ed t o a 2. 5 mm 0. 10 i nch t hi ck t emper ed har dboar d backi ng, wi t h t he backi ng bonded t o t he honeycomb cor e. Bond f aci ng sheet s t o cor es under heat and pr essur e wi t h t her moset t i ng adhesi ve and mechani cal l y l ock t o ext r uded edge member s.
b. A phenol i c r esi n- i mpr egnat ed kr af t paper honeycomb cor e. Use al umi num f aci ng sheet s mi ni mum 1. 25 mm 0. 050 i nch t hi ck and f or m i nt o t wo pans t o el i mi nat e seams on f aces. Bond honeycomb cor e t o f ace sheet s usi ng epoxy r esi n or cont act cement - t ype adhesi ve.
c. A sol i d f i br ous cor e, sur r ounded at edges and ar ound gl ass and l ouver ed ar eas and cr oss br aced at i nt er medi at e poi nt s wi t h ext r uded al umi num shapes. Use al umi num f aci ng sheet s of mi ni mum 1. 25 mm 0. 050 i nch t hi ckness. Bond f aci ng sheet s t o cor e under heat and pr essur e wi t h a t her moset t i ng adhesi ve, and mechani cal l y l ock t o t he ext r uded edge members.
d. For m f r om ext r uded t ubul ar st i l es and r ai l s mi t er ed at cor ner s, r ei nf or ce, and cont i nuousl y wel d at mi t er s. Pr ovi de f aci ng sheet s of mi ni mum 0. 8 mm 0. 032 i nch t hi ck sheet al umi num i nt er nal l y r ei nf or ced wi t h al umi num channel s or Z- bar s pl aced hor i zont al l y not mor e t han 400 mm 16 i nch apar t and ext endi ng t he f ul l wi dt h of panel s. Fi t spaces bet ween r ei nf or c i ng wi t h sound- deadeni ng i nsul at i on. Wel d f aci ng sheet s t o r ei nf or c i ng bar s or channel s and t o st i l es and r ai l s . Fi ni sh f aci ng sheet s f l ush wi t h f aces of st i l es and r ai l s .
e. For m f r om an i nt er nal gr i d composed of ext r uded al umi num t ubul ar sect i ons. Pr ovi de t ubul ar sect i ons at al l s i des and per i met er of l ouver and gl ass openi ngs. Pr ovi de t hr ee ext r uded al umi num t ubul ar sect i ons at t op and bot t om of each door . Pr ovi de wal l t hi ckness of t ubul ar sect i ons mi ni mum 2. 25 mm 0. 09 i nch except at l ock r ai l s whi ch must be mi ni mum 3 mm0. 125 i nch t hi ck, hi nge l ock r ai l s whi ch must be mi ni mum 3 mm 0. 125 i nch t hi ck, and hi nge r ai l edges whi ch must be
SECTI ON 08 11 16 Page 14 mi ni mum 5 mm 0. 19 i nch t hi ck. Fi l l spaces i n door wi t h mi ner al i nsul at i on. Pr ovi de f aci ng sheet s of al umi num mi ni mum 2. 25 mm 0. 09 i nch t hi ck.
f . For m f r om ext r uded al umi num member s at t op and bot t om, bot h s i des, and at per i met er s of l ouver and gl ass openi ngs. Pr ovi de wal l sect i ons of ext r uded al umi num member s mi ni mum 2. 25 mm 0. 09 i nch t hi ck and r ei nf or ce f or appl i cat i on of har dwar e. Cover f r ami ng member s on bot h s i des wi t h al umi num f aci ng sheet s mi ni mum 2 mm 0. 064 i nch t hi ck. Fi l l door panel s wi t h [ 172 kPa25 pounds per squar e i nch densi t y pol yst yr ene] [ 40 kg per cubi c met er 2. 5 pound per cubi c f oot densi t y, chl or of l uor ocar bon ( CFC) f r ee, f oamed ur et hane] wi t h a f l ame spr ead r at i ng of no mor e t han 25.
2. 3. 3 Wel di ng and Fast eni ng
Wher e possi bl e, l ocat e wel ds on unexposed sur f aces. Dr ess wel ds on exposed sur f aces smoot hl y. Sel ect wel di ng r ods, f i l l er wi r e, and f l ux t o pr oduce a uni f or m t ext ur e and col or i n f i ni shed wor k. Remove f l ux and spat t er f r om sur f aces i mmedi at el y af t er wel di ng. Exposed scr ews or bol t s wi l l be per mi t t ed onl y i n i nconspi cuous l ocat i ons, and must have count er sunk heads. Wel d conceal ed r ei nf or cement s f or har dwar e i n pl ace.
2. 3. 4 Weatherstripping
NOTE: Maxi mum ai r l eakage r at es ar e 2. 19 by 10- 5 cms per sq. m 0. 5 cf m per sq. f t . of door ar ea f or r esi dent i al swi ngi ng door s and 5. 48 by 10- 5 cms per
sq. m 1. 25 cf m per sq. f t . of door ar ea f or non- r esi dent i al door s. Bot h of t he ai r l eakage r at es assume t he use of t hr eshol d and sweep st r i p.
Coor di nat e wi t h Sect i on 08 71 00 DOOR HARDWARE.
Pr ovi de on st i l es and r ai l s of ext er i or door s. Fi t i nt o s l ot s whi ch ar e i nt egr al wi t h door s or f r ames. Weat her st r i ppi ng must be r epl aceabl e wi t hout speci al t ool s, and adj ust abl e at meet i ng r ai l s of pai r s of door s.
Dur i ng i nst al l at i on, ver i f y door s swi ng f r eel y and cl ose posi t i vel y. Ref er t o par agr aph AI R I NFI LTRATI ON f or ai r l eakage r equi r ement s and t est i ng.
2. 3. 5 Anchors
On t he backs of subf r ames, pr ovi de anchor s of t he s i zes and shapes i ndi cat ed f or secur i ng subf r ames t o adj acent const r uct i on. Anchor t r ansom bar s at ends and mul l i ons at head and si l l . [ Wher e i ndi cat ed, r ei nf or ce ver t i cal mul l i ons wi t h st r uct ur al st eel member s of suf f i c i ent l engt h t o ext end up t o t he over head st r uct ur al s l ab or f r ami ng and secur e t her et o. ] [ Rei nf or ce and anchor f r eest andi ng door f r ames t o f l oor const r uct i on as i ndi cat ed on appr oved shop dr awi ngs and i n accor dance wi t h manuf act ur er ' s r ecommendat i on. ] Pl ace anchor s [ as i ndi cat ed] [ near t op and bot t om of each j amb and at i nt er medi at e poi nt s not mor e t han 635 mm 25 i nch apar t ] .
2. 3. 6 Pr ovi s i ons f or Har dwar e
NOTE: Thi s gui de speci f i cat i on r equi r es t hat har dwar e and gl azi ng f or al umi num door s be speci f i ed i n t hei r r espect i ve sect i ons of t he pr oj ect specification.
SECTI ON 08 11 16 Page 15
NOTE: Wher e i t ems of har dwar e such as oper at i ng mechani sm f or bal anced door s, i nt egr al push bar s, conceal ed c l osi ng devi ces, and speci al pani c bol t s f or except i onal l y nar r ow st i l e door s ar e desi gned as an i nt egr al par t of door or f r ame const r uct i on, i t may be necessar y t o r evi se speci f i cat i on so t hese i t ems ar e f ur ni shed as par t of door and f r ame uni t .
When accessor i es, such as f i nger guar ds, el ect r i c st r i kes, aut omat i c power oper at or s, and speci al t hr eshol ds ar e r equi r ed, add as necessar y.
Coor di nat e wi t h Sect i on 08 71 00 DOOR HARDWARE. Del i ver har dwar e t empl at es and har dwar e ( except f i el d- appl i ed har dwar e) t o t he door manuf act ur er f or use i n f abr i cat i on of al umi num door s and f r ames. Cut , r ei nf or ce, dr i l l , and t ap door s and f r ames at t he f act or y t o r ecei ve t empl at e har dwar e.
Pr ovi de door s t o r ecei ve sur f ace- appl i ed har dwar e, except push pl at es, k i ck pl at es, and mop pl at es, wi t h r ei nf or c i ng onl y; dr i l l and t ap i n t he f i el d.
Pr ovi de har dwar e r ei nf or cement s of st ai nl ess st eel or st eel wi t h hot - di pped gal vani zed f i ni sh, and secur e wi t h st ai nl ess st eel scr ews. [ Pr ovi de r ei nf or cement i n cor e of f l ush door s as r equi r ed t o r ecei ve l ocks, door c l oser s, and ot her har dwar e. ]
2. 3. 7 Pr ovi s i ons f or Gl azi ng
NOTE: Thi s gui de speci f i cat i on r equi r es t hat har dwar e and gl azi ng f or al umi num door s be speci f i ed i n t hei r r espect i ve sect i ons of t he pr oj ect specification.
[ Pr ovi de ext r uded al umi num snap- i n gl azi ng beads on i nt er i or s i de of door s. ] [ Pr ovi de ext r uded al umi num, t hef t - pr oof , snap- i n gl azi ng beads or f i xed gl azi ng beads on ext er i or or secur i t y s i de of door s. ] [ Pr ovi de gl azi ng beads wi t h v i nyl i nser t gl azi ng gasket s. ] [ Desi gn gl azi ng beads t o r ecei ve t hi ckness i ndi cat ed f or each gl azed assembl y. ] Coor di nat e r equi r ement s wi t h Sect i on 08 81 00 GLAZI NG.
2. 3. 8 Finishes
NOTE: Speci f y f i ni sh desi gnat i on AA- M10- C22- A31, Ar chi t ect ur al Cl ass I I c l ear ( nat ur al ) anodi zed f i ni sh or AA- M10- C22- A32, Ar chi t ect ur al Cl ass I I col or - anodi zed f i ni sh, when door s wi l l not be subj ect t o excessi ve wear or abr asi on and wi l l be r egul ar l y c l eaned and mai nt ai ned. Speci f y f i ni sh desi gnat i on AA- M10- C22- A41, Ar chi t ect ur al Cl ass I c l ear ( nat ur al ) anodi zed f i ni sh or AA- M10- C22- A42, Ar chi t ect ur al Cl ass I col or - anodi zed f i ni sh, when door s wi l l be subj ect t o excessi ve wear and wi l l not be r egul ar l y c l eaned and mai nt ai ned. Al so speci f y t hese desi gnat i ons ( Cl ass I ) ar e used i n humi d l ocat i ons or pr oj ect l ocat i ons wi t h Envi r onment al Sever i t y Cl assi f i cat i ons ( ESC) of C3 t hr u C5. Humi d
SECTI ON 08 11 16 Page 16 l ocat i ons ar e t hose i n ASHRAE cl i mat e zones 0A, 1A, 2A, 3A, 3C, 4C and 5C ( as i dent i f i ed i n ASHRAE
90. 1) . See UFC 1- 200- 01 f or det er mi nat i on of ESC f or pr oj ect l ocat i ons. . Col or - anodi zed f i ni sh i s avai l abl e i n medi um br onze, dar k br onze, and bl ack.
Wher e r evol v i ng al umi num door s and f r ames ar e shown i n connect i on wi t h al umi num swi ng door s, exer ci se car e t o obt ai n mat chi ng col or and f i ni sh of t he t wo door t ypes.
Pr ovi de exposed al umi num sur f aces wi t h [ mi l l f i ni sh] [ f act or y f i ni sh of anodi c coat i ng or or gani c coat i ng] .
2. 3. 8. 1 Anodi c Coat i ng
Cl ean exposed al umi num sur f aces and pr ovi de an anodi zed f i ni sh conf or mi ng to AA DAF45. Pr ovi de [ c l ear ( nat ur al ) , desi gnat i on AA- M10- C22- A31, Ar chi t ect ur al Cl ass I I 0. 01 t o 0. 0175 mm 0. 4 mi l t o 0. 7 mi l ] [ c l ear ( nat ur al ) , desi gnat i on AA- M10- C22- A41, Ar chi t ect ur al Cl ass I 0. 0175 mm 0. 7 mi l or t hi cker ) ] [ i nt egr al col or - anodi zed, desi gnat i on AA- M10- C22- A32, Ar chi t ect ur al Cl ass I I 0. 01 t o 0. 0175 0. 4 mi l t o 0. 7 mi l ] [ i nt egr al col or - anodi zed, desi gnat i on AA- M10- C22- A42, Ar chi t ect ur al Cl ass I 0. 0175 mm
0. 7 mi l or t hi cker ] [ el ect r ol yt i cal l y deposi t ed col or - anodi zed, desi gnat i on AA- M10- C22- A34, Ar chi t ect ur al Cl ass I I 0. 01 t o 0. 0175 mm 0. 4 mi l t o 0. 7 mi l ] [ el ect r ol yt i cal l y deposi t ed col or - anodi zed, desi gnat i on AA- M10- C22- A44, Ar chi t ect ur al Cl ass I 0. 0175 mm 0. 7 mi l or t hi cker ] f i ni sh. [ Pr ovi de mat er i al ( s) i n col or ( s) [ _____] [ as i ndi cat ed] [ as sel ect ed f r om manuf act ur er ' s [ st andar d] [ compl et e] r ange of col or opt i ons] ] .
2. 3. 8. 2 Or gani c Coat i ng
NOTE: Speci f y baked enamel f i ni sh as an opt i on t o Cl ass I I anodi zed. Speci f y hi gh- per f or mance f i ni sh as an opt i on t o Cl ass I anodi zed.
Cl ean and pr i me exposed al umi num sur f aces. Pr ovi de [ a baked enamel f i ni sh i n accor dance wi t h AAMA 2603 wi t h t ot al dr y f i l m t hi ckness mi ni mum 0. 02 mm
0. 8 mi l ] [ a hi gh- per f or mance f i ni sh i n accor dance wi t h AAMA 2604 wi t h t ot al dr y f i l m t hi ckness of mi ni mum 0. 03 mm 1. 2 mi l s] . Fi ni sh col or t o be [ _____] [ as i ndi cat ed] [ as sel ect ed f r om manuf act ur er ' s [ st andar d] [ compl et e] r ange of col or opt i ons] .
PART 3 EXECUTI ON
3. 1 INSTALLATION
Pl umb, squar e, l evel , and al i gn f r ames and f r ami ng member s t o r ecei ve door s[ , t r ansoms] [ , adj oi ni ng s i de l i t es] [ , and] [ , adj oi ni ng wi ndow wal l s] .
Anchor f r ames t o adj acent const r uct i on as i ndi cat ed and i n accor dance wi t h manuf act ur er ' s pr i nt ed i nst r uct i ons and t he appr oved shop dr awi ngs.
I nst al l anchor age t hat compl i es wi t h appl i cabl e st r uct ur al r equi r ement s.
Anchor bot t om of each f r ame t o r ough f l oor const r uct i on wi t h 2. 4 mm 3/ 32 i nch t hi ck mi ni mum st ai nl ess st eel angl e c l i ps secur ed t o back of each j amb and t o f l oor const r uct i on; use st ai nl ess st eel bol t s and expansi on r i vet s f or f ast eni ng c l i p anchor s. Hang door s t o pr oduce cl ear ances speci f i ed i n par agr aph ALUMI NUM DOORS. Af t er er ect i on and gl az i ng, adj ust door s and
SECTI ON 08 11 16 Page 17 har dwar e t o oper at e pr oper l y.
3. 2 PROTECTI ON FROM DI SSI MI LAR MATERI ALS
3. 2. 1 Di ssi mi l ar Met al s
Wher e al umi num sur f aces come i n cont act wi t h met al s ot her t han st ai nl ess st eel , z i nc, or smal l ar eas of whi t e br onze, pr ot ect f r om di r ect cont act t o di ssi mi l ar met al s.
3. 2. 1. 1 Protection
Pr ovi de one of t he f ol l owi ng syst ems t o pr ot ect sur f aces i n cont act wi t h di ssi mi l ar met al s:
a. Pai nt t he di ssi mi l ar met al wi t h one coat of heavy- bodi ed bi t umi nous paint.
b. Appl y el ast omer i c seal ant bet ween al umi num and di ssi mi l ar met al s i n accor dance wi t h Sect i on 07 92 00 JOI NT SEALANTS.
c. Pai nt di ssi mi l ar met al s wi t h one coat of pr i mer and one coat of al umi num pai nt .
d. Use a non- absor pt i ve t ape or gasket i n per manent l y dr y l ocat i ons.
3. 2. 2 Dr ai nage f r om Di ssi mi l ar Met al s
I n l ocat i ons wher e dr ai nage f r om di ssi mi l ar met al s has di r ect cont act wi t h al umi num, pr ovi de pr ot ect i ve pai nt t o pr event al umi num di scol or at i on.
3. 2. 3 Masonr y and Concr et e
Pr ovi de al umi num sur f aces i n cont act wi t h mor t ar , concr et e, or ot her masonr y mat er i al s wi t h one coat of heavy- bodi ed bi t umi nous pai nt .
3. 2. 4 Wood or Ot her Absor pt i ve Mat er i al s
Pr ovi de al umi num sur f aces i n cont act wi t h absor pt i ve mat er i al s subj ect t o f r equent moi st ur e, and al umi num sur f aces i n cont act wi t h t r eat ed wood, wi t h t wo coat s of al umi num pai nt or one coat of heavy- bodi ed bi t umi nous pai nt .
I n l i eu of pai nt i ng al umi num, pai nt t he wood or ot her absor pt i ve sur f ace wi t h t wo coat s of al umi num pai nt and seal j oi nt s wi t h el ast omer i c seal ant .
3. 3 SEALI NG AROUND ASSEMBLI ES
Seal al l penet r at i ons of t he ai r bar r i er by seal i ng ar ound door openi ngs as necessar y t o achi eve compl i ance wi t h ai r l eakage r equi r ement s i ndi cat ed i n [ t he ai r bar r i er sect i ons of t he speci f i cat i ons] [ , t he r equi r ement s of Sect i on 07 27 10. 00 10 BUI LDI NG AI R BARRI ER SYSTEM] [ , and Sect i on 07 05 23 PRESSURE TESTI NG AN AI R BARRI ER SYSTEM FOR AI R TI GHTNESS] . Fl ash al l door s wi t h cor r osi on r esi st ant f l ashi ng t o pr event wat er i nt r usi on.
3. 4 CLEANING
Upon compl et i on of i nst al l at i on, c l ean door and f r ame sur f aces i n accor dance wi t h door manuf act ur er ' s wr i t t en r ecommended pr ocedur e. Do not use abr asi ve, caust i c, or aci d c l eani ng agent s.
SECTI ON 08 11 16 Page 18
3. 5 PROTECTION
Pr ot ect door s and f r ames f r om damage and f r om cont ami nat i on by ot her mat er i al s such as cement mor t ar . Pr i or t o compl et i on and accept ance of t he wor k, r est or e damaged door s and f r ames t o or i gi nal condi t i on, or r epl ace wi t h new ones.
- - End of Sect i on - -