PDPG162004_Quad_SD_Repair_Site_Plan.pdf

PDF 3 MB Posted

Attached to
QUAD STORM DRAIN REPAIR Federal contract opportunity
Solicitation number
W912LA-16-R-8001
Issued by
Department of the Army National Guard

About this file

Quad Storm Drain Site Plan

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

stmdr9 stmdr7stmdr6 stmdr5stmdr3 stmdr2 stmdr52 stmdr51stmdr50 stmdr49stmdr48 stmdr47 stmdr46 stmdr44 stmdr43stmdr42 stmdr41 stmdr40stmdr39 stmdr38 stmdr37 stmdr36stmdr35 stmdr34stmdr33 stmdr32stmdr31 stmdr30 stmdr29stmdr28 stmdr27stmdr26stmdr25stmdr24stmdr23stmdr22stmdr21stmdr20stmdr19 stmdr18 stmdr16 stmdr15stmdr14 stmdr13 stmdr12stmdr11 tony.alves Polygonal Line tony.alves Line tony.alves Line tony.alves Polygonal Line tony.alves Polygonal Line tony.alves Line tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Line tony.alves Rectangle tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Callout

CB6

TG 38.86

INV 37.20

tony.alves Callout

CB5

TG 38.51

INV 35.93

tony.alves Text Box

15" CMP

tony.alves Callout

NEW PIPE OVER 4" HV ELEC (TOP OF SLURRY 33.70)

tony.alves Callout

REMOVE (2) 12" INLETS & 10'D PVC LOOP

tony.alves Callout

CB1

CURB INLET

tony.alves Callout

TG 37.41

INV 31.91

tony.alves Callout

TG 37.62

INV 31.45

tony.alves Callout

INV 31.70

TG 36.78

INV 28.95

tony.alves Callout

INV 28.25

TG 36.75

INV 32.90

tony.alves Callout

CB2

TG 36.70

INV 32.20

tony.alves Callout

INV 32.63

tony.alves Callout

INV 32.97

tony.alves Callout

CB3

TG 37.74

INV 32.24

tony.alves Callout

CB4

TG 38.52

INV 35.27

tony.alves Callout

INV 31.60

tony.alves Line tony.alves Callout

12" PVC

tony.alves Callout REPLACE CMP W/ 10" HDPE PIPE. RAISE PIPE AS REQUIRED AT CB3 FOR CONT SLOPE TO CB1 tony.alves Callout

REPLACE CMP W/ 15" HD STORM PIPE TO CB1. RAISE AS REQUIRED FOR CONT SLOPE TO CB1

tony.alves Text Box

SITE PLAN

QUAD STORM DRAIN REPAIR

163 CES MARB PDPG162004 WO201600470

04 JAN 2016

tony.alves Callout

POC OF CMP & HDPE (EDGE OF SIDEWALK)

tony.alves Polygonal Line tony.alves Text Box

12" PVC

tony.alves Text Box

15" CMP

tony.alves Text Box

32" RCP

tony.alves Text Box

10" CMP

tony.alves Text Box

8" PVC

tony.alves Text Box

8" CMP

tony.alves Text Box

8" CMP

tony.alves Text Box

8" CMP

tony.alves Text Box

8" CMP

tony.alves Text Box

8" PVC

tony.alves Text Box

8" PVC

tony.alves Polygonal Line tony.alves Text Box 100' tony.alves Rectangle tony.alves Callout

CONNECT 4" PVC TO NEW PIPE

tony.alves Callout

DEMO 20'H 18" DIA TREE. CHIP ROOTS 6" BELOW FG

tony.alves Callout REPLACE CMP W/ 15" HD STORM PIPE. RAISE AS REQUIRED TO CLR ELEC SLURRY & FOR CONT SLOPE TO CB2 tony.alves Text Box

NOTES

1. ELEVATIONS INDICATED ARE EXISTING, CONTRACTOR TO VERIFY

2. PIPE SLOPE SHALL BE .5% MIN

3. MOD OR REPLACE CATCH BASINS AS REQD TO ACCOMODATE NEW PIPE ELEVATIONS

4. CB MOD INCLUDES REMOVE CMP & PATCH HOLE, CORE & GROUT NEW PIPE, AND FILL CONC TO INVERT

5. REGRADE ~15'x15' AROUND CB (TYP OF 15) FROM 2" BELOW TG STRAIGHT GRADE TO MEET EXISTING

6. REPAIR DAMAGED SPRINKLER LINES FROM CONSTRUCTION

7. GRADE LEVEL BUT DO NOT REPLACE LANDSCAPE

8. PCC WALK SHALL BE 4" THICK W/ 6X6X10 GA WWM REINFORCING

tony.alves Oval tony.alves Text Box

12" PVC

tony.alves Callout

CIPP LINING FROM CB6 TO POC

tony.alves Line tony.alves Callout

REPLACE CMP W/ 8" HDPE PIPE TO POC AT EXISTING INVERTS

tony.alves Text Box

10" PVC

tony.alves Callout

CAP ABANDONED 8" CMP W/ CONC

tony.alves Callout 12x12 DECK DRAINS W/ 4" PVC DOWN TO CMP (TYP OF 3) tony.alves Callout RAISE PAVERS on sand AREA APPOX 3'X3' AROUND 12x12 DECK DRAINS TO FS AND REPLACE PLASTIC GRATES W/ SS (TYP OF 5) tony.alves Text Box

GRASS

tony.alves Text Box

GRASS

tony.alves Text Box

GRASS

tony.alves Text Box

GRASS

tony.alves Text Box

GRASS

tony.alves Text Box

GRASS

tony.alves Callout REMOVE (2) 12" INLETS & 10'D PVC LOOP. RAISE GRADE TO SURFACE DRAIN OVER SIDEWALK tony.alves Callout

CB12 THRU CB15 NOT SHOWN

tony.alves Rectangle tony.alves Callout 10'Lx1'Dx~2'W CONC INLET STOP W/ (2) #4 T&B & #4 LOOPS @2' OC TO CLOSE OFF INLET & ALIGN TO SIDEWALK tony.alves Callout

CONC SWALE

tony.alves Callout

CB10

tony.alves Callout

CB11

tony.alves Callout

CB7

tony.alves Callout

CB8

tony.alves Callout

CB9

tony.alves Rectangle tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Callout

REGRADE AREA TO CHANGE SURFACE FLOW FROM CB1 TO CB2

tony.alves Callout

DEMO 30'H 18" DIA TREE. CHIP ROOTS 6" BELOW FG

tony.alves Text Box

PAVERS

tony.alves Line tony.alves Line tony.alves Line tony.alves Callout

GRADE TO SURFACE DRAIN AREA TO CB2

tony.alves Callout

REPAIR PCC WALK

tony.alves Callout

REPLACE ~15' OF CRACKED PCC WALK. RAISE TO ALIGN W/ WALK

tony.alves Rectangle tony.alves Polygon tony.alves Rectangle tony.alves Callout

ENCLOSURE

tony.alves Oval tony.alves Oval tony.alves Callout REGRADE ~20'x20' - 4" BELOW TOP OF MANHOLE LIDS tony.alves Line tony.alves Line tony.alves Line tony.alves Rectangle tony.alves Text Box

TOILETS

tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Rectangle tony.alves Oval tony.alves Oval tony.alves Text Box 0' tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Line tony.alves Text Box N tony.alves Polygon tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Oval tony.alves Oval

File details come from the government source that posted it. Updated .