Requirements.pdf
PDF 224 KB Posted
- Attached to
- Camp Atterbury Firehouse Caging
- Solicitation number
- W912L9-26-Q-A009
- Issued by
-
Department of the Army National Guard
About this file
This document is a specification sheet for storage and containment equipment to be installed across multiple locations within a facility. The equipment is organized by location and includes detailed dimensional and material specifications for each item.
The Upstairs Left area requires caging (17' width x 15'6" to 14'2" sloped height with 6' sliding gate) constructed from 2" x 2" posts and 10 gauge, 2" x 1" woven wire mesh, plus four duffel bag locker units (48"W x 30"D x 90"H, five lockers per unit) fabricated from 2-gauge steel bases with 6-gauge sides, ends, and lids, each with 200-pound capacity. The Upstairs Right area specifies two-sided caging (29"W x 17'L with heights ranging from 13'4" to 15'10" with sloped configuration) with matching construction specifications, supplemented by ten MiniRack units in varying dimensions (six units at 72"L x 30"W x 87"H, two at 96"L x 30"W x 87"H, and two at 96"L x 48"W x 87"H), each with five beam levels featuring 1,200-pound capacity per level and steel decking. The Ground Level area requires forty fully-framed, all-welded lockers (18"W x 22"D x 72"H) with welded 4" bases, delivered fully assembled in pairs, featuring ventilated doors with padlock hasps, single-prong hooks, stainless steel coat rods, and ventilated bottom shelves with expanded metal sides. All locations require gray-colored equipment. The document indicates recent modifications highlighted in red, specifically affecting the Upstairs Left caging specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers.pdf | ||
| Questions and Answers.pdf | ||
| Requirements.pdf | ||
| W912L9-26-Q-A009.pdf | ||
| W912L9-26-Q-A009.pdf | ||
| Requirements.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Location Description Color
CAGING:
* 17' Width x 15'6 to 14'2" slope Height, with 6'W sliding gate, padlock hasp & keyed
* Cage will extend to the ceiling
* Posts: 2" x 2", Wire Panels: 10 gauge, 2" x 1" woven wire mesh DUFFEL BAG LOCKERS - Four (4) Units
* 48"W x 30"D x 90" Over All Height - 5 Lockers per Unit
* 17"H/Locker, Full drop front panel, Secure with Padlock
* 2 Gauge steel base, 6 gauge sides, end & lid
* Open Mesh Pattern with 200lb. Cap./locker
2-SIDED CAGING
* 29"W x 17'L Height is sloped ranging from 13'4" at East Side to 15'10" on the southwest side to 14'9" on the north west side of the cage. This requires a 6'W sliding gate, padlock hasp & keyed lock
* Posts: 2" x 2", Wire Panels: 10 gauge, 2" x 1" woven wire mesh.
MINIRACK - Ten (10) Units
* 6 EA: 72”L x 30”W x 87” H
* 2EA: 96”L x 30”W x 87”H
* 2EA: 96”L x 48”W x 87”H
* 5 Beam Levels with Steel Decking (1200 lb. capacity per level) Fully-Framed All-Welded Lockers - Forty (40)
* 18"W x 22"D x 72"H
* Welded 4" Base
* 2 Single Prong hooks on the sides with 1 stainless steel coat rod
* Top Shelf with 12"H clearance
* Single Tier with ventilated doors with padlock hasps
* Fully assembled in PAIRS (20 pairs = 40 frames)
* Ventilated bottom shelf with expanded metal sides
Ground Level Gray
Upstairs Left
Gray
Gray
Gray
Gray
Upstairs Right
***Change is highlighted in RED***
Sheet1
File details come from the government source that posted it. Updated .