CTE_Tent_layouts_10APR19.pptx

PPTX presentation 6 MB Posted

Attached to
Tent Rental with additional services
Solicitation number
W912L919U0014
Issued by

About this file

Additional tent location / layout information

View the file

Other files

File Type Posted
Questions_with_Answers_-_4_12_2019.pdf PDF
W912L9-19-U-0014_-_Modification_1.pdf PDF
CTE_Tent_layouts_23MAY19.pptx PPTX presentation
W912L9-19-U-0014.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Area of Operations Training site is the corner lot located at N 22nd ST and Headquarters Ave, North Fort Hood, TX.

Note: The training lot is an empty compound with 7 power poles running down the center of the compound.

Power poles may be utilized to provide shore power to leased tents and HVAC systems.

North Here

North Fiber Pedestal Fiber to/from EXCON (WARSIM)

34ID

Training site is the corner lot located at N 22nd ST and Headquarters Ave, North Fort Hood, TX.

Note: The training lot is an empty compound with 7 power poles running down the center of the compound.

Power poles may be utilized to provide shore power to leased tents and HVAC systems.

38th ID OSS CTE – Tent Layouts

UNCLASSIFIED//FOUO

v 2.0, as of 18 JUL 18

SNAP Terminals

Zone 2 tent 506 Annex TIP-C (G2 Intel Tent) MCP G6 Server Tent TCP G6 NETOPS Tent Entry Control Point

Parking

Layout for Signal Tents Signal tents layout TIP-C tent layout

Location/BuildingSquare Feet
ANNEX Tent70 x 120 (8,400 sq ft)
Zone 2, Tent 506 MCP+COIC90 x 150 (13,500 sq ft)
Signal Tent (MCP)20 x 30 (600 sq ft)
Signal Tent (TCP)20 x 30 (600 sq ft)
TIP-C (G2 INTEL)30 x 40 (1200 sq ft)
TOTAL Sq Ft24,300 sq ft

Tent size overview

TENTSIZEQTYAPPROXIMATE OFFICE SIZEOFFICE QTYPower OutletsSPECIAL REQUIREMENTS
Annex Tent120’ by 70’
(8,400 SQ FT)1120’ by 60’
(6,844 SQ FT)11 per work stations (96 outlets)12 wall dividers (20’ in length). 4 power outlets on each side of dividers.
24’ by 10’
(2400 SQ FT)12 per officeHardened door required.
10’ by 10’
(100 SQ FT)82 per officeHardened door required.
6’ by 10’
(80 SQ FT)112 outletsIT Room must be able to be cooled below 70º F.
Signal Tent (MCP)20’ by 30’
(600 SQ FT)11 outlet per workstation (4) and 12 additional outlets.Server Room. Room must be able to be cooled below 70º F.
Signal Tent (TCP)20’ by 30’
(600 SQ FT)11 outlet per workstation (4) and 12 additional outlets.Server Room. Room must be able to be cooled below 70º F.
TIP-C (G2 TSCIF)30’ by 40’
(1200 SQ FT)11,080 SQ FT11 outlet per workstation (20) and 5 additional power outlets (25)
12’ by 10’ (120 SQ FT)112 power outletsIFS Server Room. Room must be able to be cooled below 70º F.

38th ID OSS CTE – Tent Size

Zone 2 Tent150’ by 90’
(13,500 SQ FT)1CMD Room:

55’ by 40’

(2,200 SQ FT)150 outlets (one per workstation and additional outlets for printers and C2 equipment).Room must be fully sectioned off from floor to ceiling with hardened access door. Room partitioned by dividers per attached layout.
G Staff Support Operations:

46’ by 40’

(1840 SQ FT)11 per workstation and 6 per wood shed room (48 workstations, 6 additional= 54 outlets)Room must be sub-divided/ partitioned by attached layout. Wood shed as IT room and must be cooled below 70º F.
Honor and Safety:

27’ by 35’

(1200 SQ FT)11 per workstation, 6 outlets in the Honor Room, 10 outlets open area (23 total)Room partitioned per layouts.
Smith Room

20’ by 40’

(80 SQ FT)112 outlets
JOPES Office

14’ by 10’

(1400 SQ FT)

16 outlets (one per workstation and 2 additional)Room can be partitioned by dividers.
G Staff Offices

20’ by 101’

11 per workstation (59 outlets)Room partitioned by dividers per attached layout.
G Staff Offices

20’ by 94’ 1 1 per workstation, (20 outlets) 2 additional power outlets per DCGO and DCG office (24 total outlets). Room partitioned by dividers per attached layout.

38th ID OSS CTE – Tent Size Cont’d

Layout for ANNEX Tent 38th ID OSS CTE – DHHB (D) Tent Layouts (DHHB & G8, DIV CH) (May be staffed by Division staff as DHHB will have other accomodations) v 1.0, as of 21 MAR19

Front Rear

B Co

CDR / 1SG

C Co

CDR / 1SG

A Co

CDR/1SG

HSC

CDR / 1SG

HHBn

XO

HHBn

CDR

HHBn

CSM

Conference RM

Open Workspace

PAO

HHBn S2/ S3

S4/

PBO

S1

MAINT

DIV

CH

MEDICAL

_____________________70’____________________

B Co

G1

G8

A Co

SJA

DIV SURG

DIV Safety

CA

21 SIPR

47 NIPR

4 VOIP

2 Printers 1 Projector 1 Shedder

D# Tent/Room Number

D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15

D16 D17 D18 D19 D20

Layout Overview for Zone 2, Tent 506 55’ 150’ 90’ 46’ 5’ 17’ 27’ 13’ 18’ 35’ 10’ 25’ 5’ 10’ 40’ 5’ 5’ 40’ 20’ 20’ 20’ 16’ 20’

DOOR

DOOR

DOOR

DOOR

CMD ROOM

55X40

G STAFF SUPPORT OPERATIONS

46X40

HONOR AND SAFETY

27X35

SMITH ROOM

20X40

JOPES OFFICE

20X10 G-Staff Offices 20x101 G-Staff Offices 20X94

5’ 16’

Detailed Layout for Zone 2, Tent 506 55’ 150’ 90’ 46’ 5’ 17’ 27’ 13’ 18’ 35’ 10’ 25’ 10’ 20’ 25’ 5’ 5’ 40’ 20’ 20’ 20’ 20’ 20’ 23’ 16’ 10’ 12’ 20’

DOOR

16’ 20’ 20’ 15’ 23’ 14’ 20’ 12’ M10

SURG

PROT

M16

FUOPS

M17

M3 M7

G6 HD

KM

G6 M4 M2 G4

EW

Plotter

DCG-S

M5

GEO-SPACE

ENG

DCGS-A

M11

G37

AMDWS

TAIS

AVN

AMD

FIRES

CONF RM

SVTC

CoS

SGS

AIDES

CG

M20

DCGS

ADSI

AMDWS

TAIS

AMPS

JOPES OFFICE

20X10

M9

JOPES

AMPS

M8

SAFETY

AMR

SPACE

SCREENS

18’

HONOR

ROOM

13’ G1

G2

WOOD SHED – CONFERENCE ROOM

12’ 10’ 10’ 10’

CSM

13’

CG -AIDE

CSM-AIDE

CoS AIDE

CG - XO

DOOR

DOOR

DCG-O

DCG-O

AID

DCG-S

AID

PSD

ARCENT GO

(NOT USED)

G3

DG3

30’

PLANS

OPS SGM

12’ 10’

ORSA

8’ 8’

20’ 14’

TRX

G7 G9

27’ image14.png image15.png image16.png image17.png image18.png image19.png image20.png image21.png image22.png image23.png image13.png image24.emf image25.png image26.png image27.png image28.png image29.png image33.png image30.png image31.png image32.png image2.png image1.png oleObject1.bin image3.wmf image4.jpeg image6.jpeg image7.png image12.jpeg

File details come from the government source that posted it.