Drawings.pdf
PDF 5 MB Posted
- Attached to
- Alter French Drain and Relocate Retaining Wall
- Solicitation number
- W912J2-17-R-0001
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 312000A_Boring_logs.pdf | ||
| Questions_&_Answers.docx | DOCX document | |
| EXHIBIT-B-Subcontractor-Consent.doc | DOC document | |
| EXHIBIT-A-Past-Performance-Relevancy-Questionnaire.doc | DOC document | |
| EXHIBIT-C-Past-Performance-References-Questionnaire.doc | DOC document | |
| W912J2-17-D-0001_Amendment_01_Solicitation_Alter_French_Drain.pdf | ||
| Exhibit-D-Offorer-Bid-Schedule.xlsx | XLSX spreadsheet | |
| EXHIBIT-B-Subcontractor-Consent.doc | DOC document | |
| EXHIBIT-A-Past-Performance-Relevancy-Questionnaire.doc | DOC document | |
| EXHIBIT-C-Past-Performance-References-Questionnaire.doc | DOC document | |
| Specifications.pdf | ||
| W912J2-17-D-0001_Solicitation_Alter_French_Drain.pdf | ||
| W912J2-17-D-0001_Solicitation_Alter_French_Drain.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
G
D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
L D
A
N G
B
M A
D I S
O N
W
I S
C O
N S
I
U S
P F
O
F
O R
W
S
C O
N S
I N
A L T
E
F
E
N C
H
D
R A
I N
G-001
COVER SHEET
KSF
CAJ
LGK
USPFO FOR WISCONSIN
TRUAX FIELD ANGB
MADISON, WISCONSIN 53704
ALTER FRENCH DRAIN
Project Location Local Vicinity Map
Project Location
Sheet Index
ANG PROJECT NO. XGFG 092032
INTERSTATE 94
INTERSTATE 90
INTERSTATE 90/94
INTERSTATE 90
WISCONSIN
INTERSTATE 94
MADISON
STOUGHTON
COTTAGE
GROVE
MARSHALL
OREGON
FITCHBURG
BROOKLYN
BELLEVILLE
VERONA
Waubesa
Lake
Lake
Kegonsa
McFARLAND
MADISON
Mendota
MIDDLETON
WAUNAKEE
DANE
MONONA
M o n o n a
Lake
SUN PRAIRIE
DEFOREST
CAMBRIDGE
DEERFIELD
NORTH
TRUAX FIELD
ANGB
T
T
P
TAXIWAY "F"
SOUTH RAMP
T
A
X
I
W
Y
B
T
A
X
I
W
T A
X I W
G
PIERSTORFF ST.
MITCHELL ST.
MILLER ST.
R
E
D
W
H
I
T
E
Y
E
L
L
O
W
W
H
I
T
E
Y
E
L
L
O
W
W
H
I
T
E
W
H
I
T
E
Y
E
L
L
O
W
W
H
I
T
E
W
H
I
T
E
W
H
I
T
E
R
E
D
TYPE B-3 FINAL
PROJECT SITE
MAIN GATE
BASE CIVIL
ENGINEERING
OFFICE
B1210
Sheet Number Sheet Title
G-001 COVER SHEET
C-021 EXISTING SITE PLAN
C-041 SITE REMOVALS PLAN
C-101 SITE IMPROVEMENTS PLAN
C-121 GRADING AND EROSION CONTROL PLAN
C-501 DETAILS
C-502 DETAILS
S-101 CONCRETE RETAINING WALL
B1
B2
B3
B4
CB
ROUND INLET
RIM = 862.33
E
E
TPED
TPED
TPED
W V
W V
W V
W V
TRANS
GM
ESP
B
B
B
B
B
B
B
W V
DS
AC
CURB INLET
RIM = 860.65
CURB INLET
RIM = 860.78
GOOSENECK DRAIN
BM1686
B
B
DS
W V
W V
W V
B
B
B
B
B
W V
CO
DS
S
MH SAN
RIM = 862.62
x x x x x x x x x x x x
CB
ROUND INLET
RIM = 863.53
FFE=863.20
RUNNING
TRACK
S L O
V
D
FFE=863.82
BECKER ST
VAULT
ASPHALT
TURF
TURF
ASPHALT
ASPHALT
ASPHALT
TURF
ASPHALT
S T
E P
S
DOCK
FFE=867.82
S T
E P
S
FFE=863.16
FFE=863.2
FFE=863.2
R A
M P
B O
T T
O M
F F
E
G V
SOIL BORINGS
POINT #
B1
B2
B3
B4
ELEVATION
862.64
862.88
863.55
863.16
NORTHING
502998.371
503047.386
503005.647
502973.494
EASTING
834384.435
834516.258
834608.981
834668.865
DS
SURVEY CONTROL DATA
POINT #
BM1686
CP1
CP2
CP3
CP4
CP5
CP6
DESCRIPTION
BM BURY-TAG
CP MAG
CP CL-WV
CP CL-MHE
CP CL-WV
CP MAG
CP CL-WV
ELEVATION
863.66
861.13
862.85
863.19
863.24
865.25
861.81
NORTHING
503079.183
503113.302
503008.264
503169.089
502984.865
502838.922
502811.240
EASTING
834435.586
834324.907
834445.302
834705.777
834501.481
834647.136
834782.569
CP1
CP2
CP3
CP4
CP5
CP6
CB
ROUND INLET
RIM = 863.42
.0
T
6" PVC INV=860.33
6" PVC SE INV=857.92
10" DI S INV=857.75
6" PVC S INV=860.12
12" RCP W INV=857.75
12" RCP E INV=857.13
10" SE INV=857.33
15" DI NW INV=857.03
24" RCP E /W INV=857.34
D
MH DRAINAGE
RIM = 861.09
12" S INV=857.83
24" RCP W INV=857.58
12" N INV=858.15
15" DI
F F
E
FFE=863.80
ACAC
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
S D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
C-021
EXISTING SITE PLAN
00 30 60
SURVEY DATA:
SURVEY DATE(S)
5/5/2016
COORDINATE SYSTEM DANE COUNTY
VERTICAL DATUM USGS NAVD 88
CONTROL SOURCE WISCORS
SURVEY UNITS US SURVEY FOOT
SITE SURVEY PLAN NOTES:
1. CONTOUR INTERVALS SHOWN ARE 1.0'.
2. PRIVATE SUBSURFACE UTILITY LOCATIONS SHOWN HEREON ARE BASED UPON GROUND
MARKINGS PLACED BY CLIENT REPRESENTATIVE. MARKINGS MAY NOT BE BY BENEFIT OF
SUBSURFACE DETECTING INSTRUMENTS AS SOME WERE MARKED PER PERSONNEL BEST
RECOLLECTION.
3. PUBLIC SUBSURFACE UTILITY LOCATIONS SHOWN HEREON ARE BASED UPON GROUND
MARKINGS PLACED BY DIGGERS HOTLINE. DIGGERS HOTLINE DOES NOT GUARANTEE THE
PRECISION OF THEIR MARKINGS. IN ACCORDANCE WITH WISCONSIN LAW, SUBSURFACE
UTILITIES MUST BE EXPOSED VIA HAND DIGGING BEFORE MACHINE DIGGING IS
PERMISSABLE. UTILITY LOCATION MARKINGS ARE VALID FOR ONLY 10 DAYS.
CONTRACTOR MUST ORDER NEW UTILITY LOCATE PRIOR TO ANY EXCAVATION.
4. SANITARY SEWER AND STORM SEWER LOCATIONS HAVE BEEN DETERMINED BY
OBSERVABLE SURFACE STRUCTURES AND RESPECTIVE FEATURES. INTERMEDIATE PIPE
LOCATIONS ARE APPROXIMATE AS ACCURATE LOCATIONS WERE NOT AVAILABLE AT TIME
OF SURVEY.
5. CONTROL POINTS AND BENCHMARKS SHOWN HEREON ARE FOR REFERENCE PURPOSES
ONLY. PRIOR TO STAKING, THE CONTROL MUST BE INDEPENDENTLY VERIFIED AS
UNDISTURBED. NO WARRANTY IS MADE WITH RESPECT TO THE ACCURACY OF CONTROL
SHOWN HEREON AS THEY ARE SUBJECT TO POTENTIAL DISTURBANCE.
LEGEND:
BENCHMARK
BOLLARD
CONTROL POINT
CLEANOUT, SANITARY OR STORM
DOWNSPOUT
ELECTRICAL / COMMUNICATIONS PEDESTAL
ELECTRICAL TRANSFORMER BOX
ELECTRICAL SERVICE PANEL
ELECTRICAL HANDHOLE/PULLBOX
FIRE HYDRANT
GAS METER
GAS VALVE
INLET, CURB
INLET, ROUND
MANHOLE, ELECTRIC
MANHOLE, SANITARY SEWER
MANHOLE, STORM SEWER
MANHOLE, TELECOMMUNICATIONS
SIGN (SINGLE POST)
SOIL BORING
SHRUB
TREE, DECIDUOUS
TREE, CONIFEROUS
WATER VALVE
GAS
ELECTRIC, UNDERGROUND
EXISTING CONTOUR LINES
FENCE
SANITARY SEWER
STORM SEWER
SWALE
TELEPHONE
WATER
VEGETATION
B
CO
DS
TRANS
ESP
E
GM
G V
CB
E
S
D
T
W V xxx.x xxx.x
KSF
CAJ
LGK
EX FENCE
CB
E
TPED
TPED
TPED
W V
W V
W V
W V
TRANS
GM
ESP
B
B
B
B
B
B
B
W V
DS
AC
GOOSENECK DRAIN
B
B
DS
W V
W V
W V
B
B
B
B
B
W V
CO
DS
S x x x x x x x x x x x x x x x x x x x
CB
x
FFE=863.20
RUNNING
TRACK
S L O
V
D
FFE=863.82
BECKER ST
VAULT
ASPHALT
TURF
TURF
ASPHALT
ASPHALT
ASPHALT
TURF
ASPHALT
S T
E P
S
DOCK
FFE=867.82
S T
E P
S
FFE=863.16
FFE=863.2
FFE=863.2
R A
M P
B O
T T
O M
F F
E
G V
DS
CB
T
D
F F
E
FFE=863.80
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
ACAC
REMOVE EXISTING ASPHALT
REMOVE INLET,
PLUG AND ABANDON SE PIPE
REMOVE INLET,
PLUG AND ABANDON PIPE
SALVAGE AND
RE-PLANT EXISTING SHRUBS
REMOVE GOOSENECK AND VERTICAL PIPE,
REMOVE ASPHALT AND CONCRETE
PLUG HORIZONTAL PIPE AND ABANDON IN-PLACE
REMOVE
TREE
CONCRETE WALL REMOVAL
(SEE 1/S-101)
SAW CUT CONCRETE
AT NEAREST JOINTS
AND RE-PLACE IN KIND
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
XX
XX
REMOVE
TREE
X
XXXXXXX
13.25'
EXISTING ASPHALT
AROUND AC UNITS
TO REMAIN
//FNC//
REMOVE AND REPLACE
TWO SECTION OF EXISTING FENCE
F
N C
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
SAW CUT AND REMOVE
ASPHALT AND CURB
REMOVE EXISTING
12" STORM PIPE
EXISTING INLET TO REMAIN
REMOVE EXISTING INLET
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
C-041
SITE REMOVALS PLAN
KSF
CAJ
LGK
X
T
E C
H C
A D
C
D
W G
A
M
00 20 40
LEGEND:
ABANDON STORM SEWER
REMOVE
REMOVE FENCE
SAW CUT PAVEMENT
ASPHALT REMOVAL
CONCRETE REMOVAL
SD\\A//
//FNC//
XXXXXXXXXXXXXXXXXXX
W V
W V
W V
W V
TRANS
GM
ESP
B
B
B
B
B
B
B
W V
DS
B
B
DS
W V
W V
W V
B
B
B
B
B
W V
CO
DS
S x x x x x x x x x x x x x x x x x x x
CB
x
G V
DS
T
D
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
S
D
A
ACAC
S L O
V
D
FFE=863.82
BECKER ST
DOCK
FFE=867.82
FFE=863.2
R A
M P
B O
T T
O M
F F
E
F F
E
FFE=863.80
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
SD
SD
S D
SD
SD
S D
SD
D
D
D
D
D
CB
CATCH BASIN
(SEE 2/C-502)
RIM=862.20
NW INVERT=859.87
STORM MANHOLE
(SEE 1/C-502)
RIM=863.71
NE INVERT=859.76
EX 10" D.I. S INVERT=857.75
EX 6" PVC S INVERT=860.12
EX 12" RCP W INVERT=857.75
C
P
ASPHALT PAVEMENT
(SEE 6/C-501 EAST SIDE)
STORM MANHOLE
(SEE 1/C-502)
RIM=863.43
INVERTS=859.36
15' - 12" RCP @ 2.66%
STORM MANHOLE
(SEE 1/C-502)
RIM=862.25
INVERTS=858.90
177' - 12" R C
P @ 0.40%
INFILTRATION STORM MANHOLE
(SEE 4/C-502)
RIM=861.50
INTERCEPT EXISTING 15" PIPE=~855.59 FIELD VERIFY
NE INVERT=858.40
STORM MANHOLE
(SEE 1/C-502)
RIM=861.60
E AND SW INVERTS=858.20
N INVERT=857.87
10' - 18" RCP @ 0.50%
CONNECT TO EXISTING INLET
S INVERT=857.60
R5.00'
46.00'
R10.00'
6.00'
CONCRETE APRON
(SEE 7,8, & 9/C-501)
ISOLATION JOINT ALONG BUIDLING
x
REPLACE FENCE SECTION
ASPHALT PAVEMENT
(SEE 6/C-501 WEST SIDE)
4-INCH SOLID
WHITE PAVEMENT
MARKING, TYP
18.00'
R
CONCRETE RETAINING
WALL (SEE 2/S-101)
STORM INLET AND CASTING
(SEE 5/C-502)
RIM=860.65
INVERTS=857.82
24' - 21" RCP @ 1.00%
REPLACE ASPHALT AND CURBS IN-KIND, TYP
REPLACE
CONCRETE
SIDEWALK
(SEE 4/C-501)
x
REPLACE FENCE SECTION
TEMPORARY ROAD CLOSURE
DURING INSTALLATION
NEAR FENCE LOCATION:
5" THICK ASPHALT TO THE EAST
4" THICK ASPHALT TO THE WEST
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
S
T
E
I M
P R
O V
E M
E N
T
A
N D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
C-101
SITE IMPROVEMENTS
PLAN
KSF
CAJ
LGK
X
T
E C
H C
A D
C
T
E
I M
P R
O V
E M
E N
A
N D
W G
A
M
00 20 40
LEGEND:
STORM INLET, ROUND
STORM SEWER MANHOLE
FENCE
STORM SEWER
ASPHALT
CONCRETE
CB
D x
SD
TYPE III BARRICADE
CLOSED
R11-2
48" X 30"
ROAD
W V
W V
W V
W V
TRANS
GM
ESP
B
B
B
B
B
B
B
W V
DS
B
B
DS
W V
W V
W V
B
B
B
B
B
W V
CO
DS
S x x x x x x x x x x x x x x x x x x x
CB
x
G V
DS
T
D
ACAC
S L O
V
D
FFE=863.82
BECKER ST
DOCK
FFE=867.82
FFE=863.2
R A
M P
B O
T T
O M
F F
E
F F
E
FFE=863.80
D
D
D
D
D
CB
CB
864.0
.0
863.5
864.5
861.5
862.5
863.0
.5
.0
M
A
T
H
X
M
A
T
M
A
T
M
A
T
M
A
T
INLET PROTECTION, TYP
(SEE 1/C-502)
SILT FENCE, TYP
(SEE 3/C-501)
STABILIZED CONSTRUCTION ENTRANCE
(SEE 2/C-501)
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
M
A
T
INLET PROTECTION,
NOT REQUIRED AFTER
ABANDONMENT
EROSION MAT
(SEE 10/C-501)
EROSION CONTROL PLAN NOTES:
1. CONSTRUCTION SITE EROSION AND SEDIMENT CONTROL SHALL COMPLY
WITH THE REQUIREMENTS OF THE WISCONSIN DEPARTMENT OF NATURAL
RESOURCES.
2. ALL EROSION CONTROL MEASURES SHALL BE ADJUSTED TO MEET FIELD
CONDITIONS.
3. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY
GRADING OR DISTURBANCE OF SURFACE MATERIAL.
4. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL
MEASURES AS NEEDED.
5. EROSION AND SEDIMENT CONTROL SHALL BE INSPECTED WEEKLY AND
WITHIN 24 HOURS OF ANY RAIN EVENT OF 0.5-INCHES OR MORE IN A 24
HOUR PERIOD. A LOG OF ALL INSPECTIONS SHALL BE MAINTAINED
THROUGHOUT THE DURATION OF THE PROJECT.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP AND REMOVAL OF
ALL SEDIMENT LEAVING THE SITE. EROSION CONTROL MEASURES SHALL
BE IN WORKING CONDITION AT THE END OF EACH WORKING DAY.
7. EROSION CONTROL MEASURES SHALL BE MAINTAINED BY THE
CONTRACTOR UNTIL THE SITE IS FULLY STABILIZED.
8. DISTURBED AREAS SHALL BE SEEDED AND MULCHED WITHIN 14 DAYS OF
THE END OF THE DISTURBANCE.
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
C-121
GRADING AND
EROSION CONTROL
PLAN
KSF
CAJ
LGK
X
T
E C
H C
A D
C
D
W G
A
M
00 20 40
LEGEND:
INLET PROTECTION
EXISTING CONTOUR LINES
PROPOSED CONTOUR LINES
GRADING LIMITS
SILT FENCE
STABILIZED CONSTRUCTION ENTRANCE
EROSION MAT
FINISHED / PROPOSED SPOT ELEVATION
FINISHED / PROPOSED SLOPE
xxx(.xx) xxx(.xx) xxx(.xx) xxx(.xx)
2%
3:1
NOT TO SCALE
INLET PROTECTION, TYPE D DETAIL
12"
4"
8"
4"x6" OVAL HOLE SHALL BE HEAT
CUT INTO ALL FOUR SIDE PANELS
GEOTEXTILE FABRIC,
TYPE FF
INLET SPECIFICATIONS
AS PER THE PLAN
DIMENSION LENGTH AND
WIDTH TO MATCH
FRONT, BACK, AND
BOTTOM TO BE MADE
FROM SINGLE PIECE OF FABRIC
FLAP
USE REBAR OR STEEL ROD
FOR REMOVAL OR FOR
INLETS WITH CAST CURB BOX
USE WOOD 2x4, EXTEND 10"
BEYOND GRATE WIDTH ON
BOTH SIDES, LENGTH VARIES,
SECURE TO GRATE WITH WIRE
OR PLASTIC TIES
MINIMUM DOUBLE STITCHED
SEAMS ALL AROUND SIDE PIECES
AND ON FLAP POCKETS, TYP
SECTION
PERSPECTIVE
UNDISTURBED GROUND
GEOTEXTILE FABRIC
(SEE SPECIFICATION NOTES)
MINIMUM 8-INCH FABRIC IN A
4x4-INCH TRENCH OR A
4-INCH DEEP V-TRENCH,
TRENCH SHALL BE
BACKFILLED & COMPACTED
M I N
I M
U M
FLOW
F
L
O
W
M
A
X
I
M
U
M
S
2x2-INCH HARDWOOD
POST OR EQUIVALENT
TRENCH
GROUND
SURFACE
TWIST METHOD
HOOK METHOD
F L
O W
F L
O W
JOINING TWO LENGTHS OF SILT FENCE
SILT FENCE NOTES:
1. ENDS OF FENCE SHALL BE TURNED UPSLOPE 1 TO 2 FEET IN ELEVATION TO PREVENT FLANKING.
2. STAPLE FABRIC WITH MINIMUM 1/2-INCH STAPLES TO THE UPSLOPE SIDE OF THE POSTS.
3. FABRIC SHALL BE FROM A CONTINUOUS ROLL IF POSSIBLE. WHEN TWO SECTIONS OF FILTER
FABRIC ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY EITHER THE HOOK METHOD
WHERE TWO FENCES ARE OVERLAPPED 2'-0" AND EACH FENCE END IS ANGLED TOWARD THE
FLOW DIRECTION FOR THE 2'-0" LENGTH OR THE TWIST METHOD WHERE THE ENDS OF THE TWO
FENCES ARE OVERLAPPED AND TWISTED 180° UNTIL TWO POSTS ARE TOGETHER.
4. 8'-0" POST SPACING ALLOWED IF A WOVEN FABRIC IS USED.
5. FOLLOW WISCONSIN DNR TECHNICAL STANDARD 1056.
GEOTEXTILE FABRIC SPECIFICATIONS:
1. GRAB STRENGTH: 120 LB. MIN. IN ANY PRINCIPAL DIRECTION (ASTM-D-1682)
2. MULLEN BURST: MIN. 200 P.S.I. (ASTM D-3786)
3. EQUIVALENT OPENING SIZE:
· BETWEEN 50 AND 140 FOR SOILS WITH MORE THAN 15 PERCENT BY WEIGHT PASSING A NO.
200 SIEVE.
· BETWEEN 20 AND 50 FOR SOILS WITH LESS THAN 15 PERCENT BY WEIGHT PASSING A NO.
200 SIEVE.
4. WATER FLOW RATE OF 10 GAL/MIN/SQ.FT. AT 50MM CONSTANT HEAD IS DETERMINED BY
MULTIPLYING PERMITTIVITY IN SEC-1 AS DETERMINED BY ASTM D-4491 BY A CONVERSION
FACTOR OF 74.
5. ULTRA VIOLET RADIATION STABILITY OF 90%.
6. FABRIC WITH SUPPORT NETTING SHALL BE REINFORCED WITH AN INDUSTRIAL POLYPROPYLENE
NETTING WITH A 3/4 INCH SPACING OR EQUIVALENT. A HEAVY DUTY NYLON TOP SUPPORT
CORD OR EQUIVALENT IS REQUIRED.
GEOTEXTILE
FABRIC
POST
POST
GEOTEXTILE
FABRIC
GEOTEXTILE
FABRIC
POST
GEOTEXTILE
FABRIC
POST
M I N
I M
U M
M A
X I M
U M
2'
MAXIMUM
NOT TO SCALE
SILT FENCE DETAIL
EPOXY-COATED SMOOTH STEEL DOWELS, 1-INCH IN DIAMETER,
14-INCH IN LENGTH, SPACED AT 12-INCHES, PLACED IN BOTH DIRECTIONS,
OIL PRIOR TO CONCRETE PLACEMENT,
(PAINTED CAN BE SUBSTITUTED FOR EPOXY COATED)
WEST SIDE
ASPHALT PAVEMENT
(2-INCH BINDER, 2-INCH SURFACE)
SUBGRADE
NOT TO SCALE
ASPHALT PAVEMENT DETAIL
8-INCH THICK PORTLAND
CEMENT PAVEMENT
T
JOINT SEALER
T
7" 7"
NOTE:
1. T = PAVEMENT THICKNESS (SEE 7/C-501)
NOT TO SCALE
DOWELED CONTRACTION JOINT DETAIL
T
JOINT SEALER
T
7" 7"
DOWELS THAT NEED TO BE DRILLED INTO EXISTING
CONCRETE SHALL HAVE HOLE BLOWN CLEAN AND DOWEL
EPOXIED. ALSO PLACE AT EXISTING PAVEMENTS WHERE
INDICATED AND AT CONTINUATION OF NEXT DAY PAVING
EPOXY-COATED SMOOTH STEEL DOWELS,
1-INCH IN DIAMETER,
14-INCH IN LENGTH, SPACED AT 12-INCHES,
PLACED IN BOTH DIRECTIONS,
OIL PRIOR TO CONCRETE PLACEMENT,
(PAINTED CAN BE SUBSTITUTED FOR EPOXY COATED)
NOTE:
1. T = PAVEMENT THICKNESS (SEE 7/C-501)
NOT TO SCALE
DOWELED CONSTRUCTION JOINT DETAIL
NOT TO SCALE
CONCRETE APRON DETAIL
BASE COURSE
SECTION
SUBGRADE
BASE COURSE
R
O
A
D
W
A
Y
NOTE:
MAINTAIN THE TRACKING PAD IN A CONDITION TO PREVENT SEDIMENT FROM LEAVING THE
SITE. SHOULD MUD BE TRACKED OR WASHED ONTO EXISTING PAVEMENT, IT MUST BE
REMOVED IMMEDIATELY.
M
I
N
I
M
U
M
M
I
N
I
M
U
M
3-INCH TO 6-INCH
WASHED STONE
EXISTING PAVEMENT
10' 4' 36'
MINIMUM
LEVEL SECTION
6-INCH HUMP TO DIVERT
RUNOFF FROM PAVED ROAD
M I N
I M
U M
M I N
I M
U M
PLAN
SECTION
NOT TO SCALE
STABILIZED CONSTRUCTION ENTRANCE
2%
2% SLOPE
NOT TO SCALE
SIDEWALK DETAIL
4" 5' 4"
4" THICK
4000 PSI CONCRETE
4" THICK GRANULAR FILL
6"
30"
NOT TO SCALE
30" CONCRETE CURB AND GUTTER
R3"
EAST SIDE
ASPHALT PAVEMENT
(2-INCH BINDER, 3-INCH SURFACE)
O
R
E X
I S
T I N
G
SUBGRADE
BASE COURSE
4.
2.
5.
1.
3(A)
3(B)
1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING SEED.
2. BEGIN AT THE TOP OF THE SLOPE OR CHANNEL BY ANCHORING THE
BLANKET IN 6" DEEP X 6" WIDE TRENCH. BACKFILL AND COMPACT
THE TRENCH AFTER STAPLING.
3. ROLL THE BLANKETS (3A.) DOWN OR (3B.) HORIZONTALLY ACROSS THE
SLOPE.
4. THE EDGES OF PARALLEL BLANKETS SHALL BE STAPLED WITH 4"
OVERLAP. USE ONLY BIODEGRADABLE STAPLES.
5. WHEN BLANKETS MUST BE SPLICED DOWN THE SLOPE OR CHANNEL,
PLACE BLANKETS END OVER END (SHINGLE STYLE) WITH 6"
OVERLAP. STAPLE APPROXIMATELY 12" APART.
6. ALL BLANKETS MUST BE SECURELY FASTENED TO THE SLOPE OR
CHANNEL BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS
AS RECOMMENDED BY THE MANUFACTURER.
7. USE EROSION CONTROL REVEGETATIVE MAT (ECRM) CLASS-1, TYPE-B.
CHANNEL INSTALLATION
SLOPE INSTALLATION
M
N
NOT TO SCALE
EROSION MAT INSTALLATION DETAIL
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
T
A I L
S D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
X
T
E C
H C
A D
C
T
A I L
S D
W G
A
M
DETAILS
KSF
CAJ
C-501
NOTES:
1. 4-FOOT DIAMETER MANHOLE SHALL BE
CONSIDERED STANDARD.
2. PROVIDE LARGER DIAMETER MANHOLES
WHERE SHOWN ON PLAN.
3. MANHOLE BASE SHALL BE CAST
MONOLITHICALLY WITH THE BARREL SECTION.
BOTTOM BARREL SECTION SHALL BE A MINIMUM
OF 28 INCHES HIGH.
4. PROVIDE A MINIMUM OF 4-INCHES OF RING
ADJUSTMENT.
5. WHEN ADDITIONAL ADJUSTMENT IS REQUIRED,
IT SHALL BE DONE WITH A COMBINATION OF
RINGS THICKER THAN 2-INCHES.
CASTING
(R-1500 OR EQUAL)
ADJUSTING RINGS
ECCENTRIC
CONE
SECTION
MANHOLE
STEPS 16" O.C.
5"
MIN
MAXIMUM PIPE
INSIDE DIAMETER
STRAIGHT
THROUGH TO 45°
DEFLECTION
MAXIMUM PIPE
INSIDE DIAMETER
90° DEFLECTION
4' MANHOLE 18" 18"
5' MANHOLE 30" 27"
6' MANHOLE 42" 30"
4"
COMPACTED 3/4"
GRANULAR BASE
NOT TO SCALE
STORM MANHOLE DETAIL
NOTES:
1. PRECAST INLET IN ACCORDANCE WITH THE SPECIFICATIONS.
2. BASE SHALL BE MONOLITHIC WITH THE RISER SECTION BOTTOM
A MINIMUM OF 24 INCHES HIGH.
PROFILE
PLAN
NOT TO SCALE
48-INCH CATCH BASIN DETAIL
OUTFLOW PIPE
INFLOW PIPE
OR ORIFICE
INFLOW OR OUTFLOW PIPE
RECTANGULAR CASTING NF-R-3472
MANHOLE STEPS 16"
ON CENTER IF GREATER
THAN 4' DEEP
24"x24" OPENING
48"
5" MIN
4"
COMPACTED 3/4"
BASE COURSE
NOTE:
BOTTOM OF TRENCH SHALL BE THE PIPE O.D. PLUS 16-INCHES
EXCAVATED
MATERIAL
CLEAN EARTH FILL COMPACTED
TO 95 PERCENT STANDARD
PROCTOR DENSITY
UNDISTURBED SOIL
3/4-INCH CRUSHED STONE
ASTM D 448 - NO. 67
TAMPED IN PLACE
PIPE O.D.
M I N
I M
U M
D
NOT TO SCALE
CONCRETE (RCP) PIPE BEDDING DETAIL
4'-0"
12-FT. DIA.
15"
SAND SUBGRADE
5" MIN.
NOT TO SCALE
INFILTRATION MANHOLE DETAIL
CASTING NEENAH
R-1500 OR EQUAL
RIM ELEVATION=861.50
CONCRETE RISERS AS
NECESSARY FOR POSITIVE
DRAINAGE AWAY FROM MANHOLE
4-FOOT DIAMETER MANHOLE WITH
AN 18-INCH SQUARE FULL-DEPTH
OPENING THROUGH THE BASE SLAB
ESTIMATED
ELEVATION=854.10
GEOTEXTILE
FILTER FABRIC
SIZE NO. 2 ASTM C-33 WASHED CRUSHED
STONE WRAPPED WITH GEOTEXTILE FILTER
FABRIC, SIZE NO. 57 STONE MAY BE USED
IMMEDIATELY BELOW MANHOLE BASE TO
PLUMB AND LEVEL MANHOLE
EXISTING 15" STORM PIPE
INVERT ELEVATION=~855.59 (FIELD VERIFY)
GEOTEXTILE FILTER FABRIC
MINIMUM 6-INCH DEEP
SIZE NO. 57 ASTM C-33 WASHED
CRUSHED STONE
NEW 12" RCP
INVERT ELEVATION=858.40
NOTES:
1. PRECAST INLET IN ACCORDANCE WITH ASTM C-478
2. BASE SHALL BE MONOLITHIC WITH THE RISER
SECTION BOTTOM RISER SHALL BE A MINIMUM OF
24 INCHES HIGH
3'
V A
R I E
S
PLAN
PROFILE
FRAME, GRATE & CURB BOX
NEENAH FOUNDARY TYPE
R3067-L OR EQUAL
NOT TO SCALE
2' x 3' STORM INLET DETAIL
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
C
T
A I L
S D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
X
T
E C
H C
A D
C
T
A I L
S D
W G
A
M
DETAILS
KSF
CAJ
C-502
RETAINING WALL FOOTING
1'-0"
TOP OF WALL
ELEVATION=870.80
TOP OF WALL
ELEVATION=865.00
S-101
6"
DOWEL NEW WALL TO
EXISTING WALL
#6 BARS @ 16" ON CENTER,
PER NOTE CR-10
(MATCH WALL STEEL LOCATIONS)
864.5
869.5
RESTORE
LANDSCAPING
TO ORIGINAL
CONDITION
MATCH EXISTING
FOOTING
ELEVATION 860.47±
FOOTING
ELEVATION 858.47
ASPHALT PAVEMENT
TURF
CONCRETE
APRON
L
L
EXISTING BUILDING FOOTING
EXISTING
RETAINING WALL FOOTING
EXISTING BUILDING WALL
TOP OF WALL ELEVATION=870.80
TOP OF EXISTING WALL ELEVATION=863.48
4"
4'-6"
10"
2'-2"
3/4" CHAMFER, TYP
FINISH GRADE
(SEE PLAN)
TOP OF WALL
(SEE PLAN FOR ELEVATIONS)
ASPHALT PAVEMENT
(SEE PLAN FOR ELEVATIONS)
WALL DOWELS
#6 BARS @ 12"
(2)#6 BARS TOP AND BOTTOM
VERTICAL BARS
TO MATCH WALL DOWELS
#6 BARS
#6 BARS @ 16"
TOP OF FOOTING
(SEE PLAN FOR ELEVATIONS)
3'-2" 10" 3'-0"
#6 BARS @ 16"
BACKFILL PER
SPECIFICATIONS
EXISTING TOPSOIL
(FILL)
EXISTING SUBGRADE
RETAINING WALL
RETAINING WALL FOOTING
EXISTING TOPSOIL
(FILL)
PROVIDE GRANULAR
BACKFILL
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
SHEET NO.
Mead & Hunt, Inc.
2440 Deming Way
Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
3141300-160703.01
August 3, 2016
X
T
E C
H C
A D
S
D
W G
A
M
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents. In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
XGFG 092032
PROJECT NO.:
8/3/16 B-3 FINAL
T R
U A
X
F
I E
G
B
M A
D I S
O N
W
I S
C O
N S
U S
P F
O
F
S
C O
N S
I N
A L T
E
N C
H
D
R A
I N
S-101
CONCRETE
RETAINING WALL
KSF
CAJ
LGK
X
T
E C
H C
A D
S
D
W G
A
M
FOUNDATION NOTES
F-1. FOOTING SUBGRADES SHALL BE CLEAN AND FREE OF DEBRIS, STANDING
WATER, AND LOOSE SOIL.
F-2. CONTROL JOINTS IN THE CAST-IN-PLACE CONCRETE FOUNDATION WALLS
SHALL BE PLACED AT SPACING NOT TO EXCEED 20' O.C. OR AS LOCATED PER
DRAWINGS AND SHOULD ALIGN WITH MASONRY CONTROL JOINTS WHERE
APPLICABLE. SEE DETAIL SHEETS FOR CONTROL JOINT DETAILS. PROVIDE
VERTICAL "V" GROOVE AT ALL CONSTRUCTION AND CONTROL JOINTS.
CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS FOR APPROVAL.
F-3. A LEAN CONCRETE MUD SLAB 2" TO 3" THICK SHALL BE USED IN THE FOOTING
EXCAVATION IF THE BOTTOM OF THE EXCAVATION TENDS TO BECOME MUDDY
AND SOFT DUE TO CONSTRUCTION ACTIVITY. LEAN CONCRETE SHALL HAVE A
MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2000 PSI.
CONCRETE & REINFORCING STEEL NOTES
MATERIAL PROPERTIES (U.N.O.)
COMPRESSIVE STRENGTH - F'c = 4 KSI
CONCRETE REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
CR-1. ALL BAR LAPS SHALL CONFORM TO ACI 318 CLASS "B" SPLICE CRITERIA. USE
TOP BAR LAP LENGTHS FOR TOP BARS IN SLABS AND BEAMS OVER 14" DEEP.
MINIMUM BAR LAPS AS FOLLOWS U.N.O.:
#3:1'-4" #4:1'-4" #5:1'-10" #6:2'-7"
CR-2. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE
MORE THAN ONE BAR MAKES UP A CONTINUOUS STRING.
CR-3. HORIZONTAL BARS SHALL BE DETAILED TO SHOW THE DISTANCE FROM AT
LEAST ONE END OF THE BAR TO THE NEAREST BUILDING GRID LINE OR WALL.
CR-4. REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 315.
CR-5. ALL REINFORCEMENT BARS SHALL BE FABRICATED IN ACCORDANCE WITH
THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND SHALL BE CLEAN
AND FREE OF GREASE AND SCALING RUST.
CR-6. PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION IN
ACCORDANCE WITH ACI RECOMMENDATIONS AND PROJECT SPECIFICATIONS.
CR-7. CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER, UNLESS NOTED
OTHERWISE:
FOOTINGS:
BOTTOM & SIDES 3"
TOP 2"
CR-8. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM WITH THE
LOCAL BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING
STANDARDS (LATEST EDITION):
"ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC."
"ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT"
"ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BLDGS."
"ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK"
CR-9. SEE SECTION 033000 OF SPECIFICATIONS FOR INFORMATION REGARDING
CONCRETE MIX DESIGN, TESTING, MATERIALS, AND ADMIXTURES.
CR-10. ALL DOWELS INTO EXISTING CONCRETE TO BE EPOXY
ANCHORED WITH HILTI HIT-RE 500-SD ADHESIVE OR EQUIVALENT, (UNLESS
INDICATED OTHERWISE), MINIMUM 9" INCH EMBEDMENT.
GENERAL NOTES
G-1. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO START
OF CONSTRUCTION - RESOLVE ANY DISCREPANCY WITH CONTRACTING OFFICER'S
G-2. STRUCTURAL SYSTEM IS DESIGNED TO WORK AS A COMPLETED SYSTEM, ANY
SHORING OR BRACING NECESSARY DURING CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR.
G-3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SITE SAFETY AND ALL
ACCIDENTS WHICH RESULT IN DEATH, PERSONAL INJURY, OR DAMAGE TO
PROPERTY ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF
THE WORK.
DO NOT SCALE DRAWINGS!!!!
F-4. U.N.O., THE CONTRACTOR SHALL RETAIN AN INDEPENDENT, QUALIFIED
GEOTECHNICAL ENGINEERING FIRM/TESTING AGENCY TO IDENTIFY AREAS
OF POOR SOILS, TO MONITOR PROPER SUBGRADE PREPARATIONS AND TO
OVERSEE AND TEST THE PLACEMENT OF COMPACTED FILL MATERIAL.
F-5. ALL SUBTERRANEAN STRUCTURES, UTILITIES, PIPING, ETC. IIN THE AREA
OF EXCAVATIONS TO BE LOCATED AND MARKED BY CONTRACTOR PRIOR
TO EARTH REMOVAL WORK. CONTRACTOR TO MAINTAIN MARKERS UNTIL
EXCAVATION ACTIVITIES HAVE CEASED. IF UNDERGROUND UTILITY
CONFLICTS ARE DISCOVERED BEFORE OR ENCOUNTERED DURING
EXCAVATION, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY.
F-6. WHERE STRUCTURES DERIVE SUPPORT FROM FILL-SUPPORTED
FOUNDATIONS AND AT SLAB-ON-GRADE, FILL SHALL BE COMPACTED TO
98% OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D-698),
F-7. NO FILL SHALL BE PLACED OVER FROZEN, MUDDY, OR OTHER DELETERIOUS
MATERIAL. NO FILL SHALL BE PLACED OVER A PREVIOUS LIFT THAT HAS
NOT BEEN ADEQUATELY COMPACTED PER SPECIFICATIONS.
SHOP DRAWINGS
SD-1. SHOP DRAWINGS SHALL BE SUBMITTED FOR STRUCTURAL ITEMS AS REQUIRED
BY THE SPECIFICATIONS. CONSTRUCTION DOCUMENTS SHALL NOT BE
REPRODUCED FOR USE AS SHOP DRAWINGS.
SD-2. THE GENERAL CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS AND
PRODUCT DATA FOR CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS
PRIOR TO SUBMITTAL. REVIEWED SUBMITTALS SHALL BE STAMPED BY THE
CONTRACTOR. ANY SHOP DRAWING OR PRODUCT DATA NOT REVIEWED AND
STAMPED BY THE GENERAL CONTRACTOR WILL BE REJECTED. GENERAL
CONTRACTOR SHALL CLOUD OR FLAG ALL ITEMS NOT IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS AND SHALL VERIFY ALL DIMENSIONS.
SD-3. ANY CHANGES, SUBSTITUTIONS OR DEVIATIONS FROM THE ORIGINAL
CONTRACT DRAWINGS SHALL BE CLOUDED BY THE MANUFACTURER OR
FABRICATOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS WHICH ARE
CLOUDED OR FLAGGED BY SUBMITTING PARTIES SHALL NOT BE CONSIDERED
APPROVED AFTER THE ENGINEER'S REVIEW, UNLESS SPECIFICALLY NOTED
ACCORDINGLY BY THE ENGINEER.
SD-4. THE APPROVED SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT
DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY ARE NOT TO BE
CONSIDERED CHANGES TO THE ORIGINAL CONTRACT DRAWINGS. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ITEMS OMITTED OR SHOWN
INCORRECTLY ARE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT
DRAWINGS.
SD-5. SHOP DRAWING REVIEW IS INTENDED ONLY FOR GENERAL CONFORMANCE TO
THE DESIGN CONCEPT AND CONSTRUCTION DOCUMENTS.
SD-6. SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF MAJOR ERRORS
ARE FOUND DURING REVIEW.
SD-7. ALLOW A MINIMUM OF (10) WORKING DAYS FOR REVIEW OF SHOP DRAWINGS.
G-4. THE CONTRACTOR SHALL RETAIN AN INDEPENDENT TESTING AGENCY TO
PROVIDE FIELD AND LAB TESTING OF CONSTRUCTION MATERIALS AND TO
PROVIDE CONSTRUCTION INSPECTIONS. THE CONSTRUCTION INSPECTION
SHALL BE DONE BY QUALIFIED INSPECTORS THAT ARE SATISFACTORY TO
THE CONTRACTING OFFICER'S REPRESENTATIVE.
G-5. CONSTRUCTION TESTING AND INSPECTION BY THE TESTING AND INSPECTING
AGENCY IS REQUIRED AS FOLLOWS:
A. CONCRETE TESTING PER THE SPECIFICATIONS.
REPRESENTATIVE.
UNLESS NOTED OTHERWISE.
0 84
EXISTING LAYOUT AND DEMOLITION
E X
I S
T I N
G
R
E T
A I N
I N
G
W
A L
L
A
O
T I N
G
D
E M
O L
I S
H E
D
0 84
NEW RETAINING WALL PLAN
NOT TO SCALE
TYPICAL WALL SECTION
EXTERIOR EXPOSURE 2"
WALLS:
NOT TO SCALE
TYPICAL WALL EARTHWORK REQUIREMENTS
| Sheets and Views |
| G-001 COVER SHEET |
| C-021 EXISTING SITE PLAN |
| C-041 SITE REMOVALS PLAN |
| C-101 SITE IMPROVEMENTS PLAN |
| C-121 GRADING AND EROSION CONTROL PLAN |
| C-501 DETAILS |
| C-502 DETAILS |
| S-101 CONCRETE RETAINING WALL |
File details come from the government source that posted it. Updated .