Summary
| W912HV-17-R-0004 | |
| Page 3 of 63 | |
| Section 00 10 00 - Solicitation, Contract Line Item Number (CLIN) Schedule | |
| Solicitation Information | |
| Description: The United States Army Corps of Engineers, District of Japan has a requirement to provide |
construction services to the Kanto Plain area on an Indefinite Delivery, Indefinite Quantity contracting vehicle.
| Point of Contact: | |||||
| Christopher Taylor, Contract Specialist | |||||
| christopher.taylor@usace.army.mil | |||||
| Requests for Information are due no later than May 11, 2017 and shall be directed to the above individual. | |||||
| Requests for Information shall reference W912HV-17-R-0004. | |||||
| NO TELEPHONE CALLS WILL BE ACCEPTED. | |||||
| Section 00 10 00 - Solicitation, Contract Line Item Number (CLIN) Schedule | |||||
| ITEM | |||||
| NO. | DESCRIPTION | QUANTITY | UNIT | UNIT | |
| PRICE | AMOUNT | ||||
| BASE | |||||
| 0001 | THREE-YEAR BASE PERIOD | ||||
| (Total from Exhibit A) | 1 | JB | LS | ¥ - | |
| OPTIONS | |||||
| 0002 | FIRST 1-YEAR OPTION PERIOD | ||||
| (Total from Exhibit B) | 1 | JB | LS | ¥ - | |
| 0003 | SECOND 1-YEAR OPTION PERIOD | ||||
| (Total from Exhibit C) | 1 | JB | LS | ¥ - | |
| TOTAL OPTIONS | ¥ - | ||||
| TOTAL BASE AND OPTIONS: | ¥ - | ||||
| CONTRACT MINIMUM/MAXIMUM VALUE | |||||
| (a) In accordance with the requirements of FAR 52.216-22 (Section I), the minimum contract value of work that |
will be ordered through the issuance of task order under this contract shall be ¥5,500,000,000 for the life of the contract. The minimum value of the task orders that can be ordered under the provisions of this contract shall not be less than ¥3,500,000 for the life of the contract.
(b) The government will obligate the minimum guarantee at the time of awarding the basic contract, by issuing a christopher.taylor@usace.army.mil
Exhibit A
| SCHEDULE OF INDEFINITE QUANTITY WORK | ||||||||
| Exhibit A - THREE-YEAR BASE PERIOD | ||||||||
| W912HV-17-R-0004 | ||||||||
| Price to perform Indefinite Quantity Work of the Period | ||||||||
| Item | Estimated | Unit | Estimated | |||||
| Exhibit | SCLIN | No. | Description | Unit | Quantity | Price (¥) | Amount (¥) | |
| A | MAINTENANCE OF BUILDING EXTERIOR | |||||||
| A | A0001 | A | 1 | Apply surface preparation,1 coat of primer and 2 coats of emulsion paint (JIS K 5663, Type-1) on cement stucco surfaces and CACB surfaces | M² | 6,657 | ¥ - | ¥ - |
| A | A0002 | A | 2 | Apply surface preparation, 1 coat of primer and 2 coats of textured coating (JIS A 6909, Type-E) on cement stucco surfaces | M² | 37,359 | ¥ - | ¥ - |
| A | A0003 | A | 3 | Apply surface preparation, 1 coat of primer and 2 coats of ready mixed paint (JIS K 5516) on wood surfaces | M² | 2,583 | ¥ - | ¥ - |
| A | A0004 | A | 4 | Apply surface preparation, 1 coat of primer and 2 coats of enamel paint (JIS K 5572, Type-2) on steel surfaces | M² | 45,108 | ¥ - | ¥ - |
| A | A0005 | A | 5 | Apply surface preparation, 1 coat of primer and 2 coats of aluminum paint (JIS K 5492) on steel surfaces | M² | 2,058 | ¥ - | ¥ - |
| A | A0006 | A | 6 | Apply surface preparation, 1 coat of primer and 2 coats of aluminum heat resistant paint on steel surfaces | M² | 273 | ¥ - | ¥ - |
| A | A0007 | A | 7 | Apply surface preparation, 1 coat of primer and 2 coats of enamel paint (JIS K 5582, Type-2) on plastic surfaces, such as eaves, gutter and downspout | M² | 1,239 | ¥ - | ¥ - |
| A | A0008 | A | 8 | Apply surface preparation and paint safety markings-diagonal contrasting colors, 100mm wide black and yellow stripes-with 1 coat of primer and 2 coats of enamel paint (JIS K 5572, Type-2) on steel surface, such as wheel guard post and wall around vehicle entrance, etc | M² | 84 | ¥ - | ¥ - |
| A | A0009 | A | 9 | Clean exterior surfaces with high-pressure water, such as concrete, cement stucco, wood and metal surfaces | M² | 72,765 | ¥ - | ¥ - |
| A | A0010 | A | 10 | Paint bldg No. and completion date (day, month and year) in lettering as directed | EA | 105 | ¥ - | ¥ - |
| A | 11 | Replace caulking compound, including bond breaker and back-up material: | ||||||
| A | A0011 | A | a | Around door and window, etc | LM | 11,193 | ¥ - | ¥ - |
| A | A0012 | A | b | Along expansion and construction joints, etc | LM | 5,502 | ¥ - | ¥ - |
| A | A0013 | A | 12 | Remove and reinstall steel security window guards of bar grille type and diamond mesh type | M² | 483 | ¥ - | ¥ - |
| A | A0014 | A | 13 | Remove dirt, debris and leaves in eaves gutter and downspouts | LM | 1,008 | ¥ - | ¥ - |
| A | A0015 | A | 14 | Apply surface preparation, 1 coat of primer and 2 coats of sunlight reflecting roof paint on steel surfaces |
primer: epoxy resin paint, 0.18 kg / sm roof paint: fluorine fluoride ceramic resin paint,
| 0.14 kg/sm/coat | M² | 10,017 | ¥ - | ¥ - | |
| A | A0016 | A | 15 | Apply surface preparation and 2 coats of sunlight reflecting roof paint on built-up roofing |
paint : acrylic emulsion paint with aggregate, incombustible
| spread : 0.8 kg/sm/coat | M² | 4,893 | ¥ - | ¥ - | |||||
| A | A0017 | A | 16 | Apply surface preparation and 2 coats of acrylic emulsion paint on asphalt shingle roofing and modified bitumen membrane cap sheet surfaces, white color , 0.4 kg / sm in 2 coats | M² | 2,100 | ¥ - | ¥ - | |
| B | REPAIR/CONSTRUCTION OF BUILDING EXTERIOR | ||||||||
| BA | WALL WORK | ||||||||
| A | A0018 | BA | 1 | Replace wood siding with 13mm thk wood bevel siding, including wood batten, o.c 450mm | M² | 21 | ¥ - | ¥ - | |
| A | A0019 | BA | 2 | Install 0.6 mm thk precoated CGIS siding, pitch : 63.5 mm, height : 16 mm | M² | 3,297 | ¥ - | ¥ - | |
| A | A0020 | BA | 3 | Replace CFRPS Siding with 2.0mm thk CFRPS, pitch : 63mm, type : 28 FS | M² | 819 | ¥ - | ¥ - | |
| A | A0021 | BA | 4 | Replace CGIS siding with 0.6 mm thk pre-coated CGIS, pitch : 63.5 mm | M² | 105 | ¥ - | ¥ - | |
| A | A0022 | BA | 5 | Replace ribbed GIS siding with 0.6 mm thk precoated ribbed GIS, including polyurethane sealing strip, mountain height : 25 mm | M² | 1,008 | ¥ - | ¥ - | |
| A | A0023 | BA | 6 | Replace cement stucco wall with cement mortar in 3 coats | M² | 1,974 | ¥ - | ¥ - | |
| A | A0024 | BA | 7 | Replace waterproof paper and metal lath with asphalt roofing paper (2-Layers) and 0.6mm thk galvanized iron rib lath | M² | 273 | ¥ - | ¥ - | |
| A | A0025 | BA | 8 | Replace wood sheathing board with 12 mm thk waterproof plywood, type -1, or 'Tokurui' | M² | 1,197 | ¥ - | ¥ - | |
| A | A0026 | BA | 9 | Replace wood furrings with 45 x 105mm wood lumber, KD/K3 | LM | 5,502 | ¥ - | ¥ - | |
| A | A0027 | BA | 10 | Replace wood trim around door and window with wood | LM | 903 | ¥ - | ¥ - | |
| A | A0028 | BA | 11 | Replace wood head, jamb and sill of frame around door and window with wood lumber | LM | 819 | ¥ - | ¥ - | |
| A | A0029 | BA | 12 | Replace flashing with 0.6 mm thk precoated GIS | LM | 2,058 | ¥ - | ¥ - | |
| A | A0030 | BA | 13 | Replace security window guard with steel framed chain link wire fabric guard, aluminum paint finish: |
steel frame with bracket : L - 65 x 65 x 6 mm with M10 mm tamper proof bolt, o.c 450 mm, welded structure chain link wire fabric : 3.8 mm diameter with 50 mm mesh opening, welded to steel frame through
| 3.8 mm diameter weaving bar, galvanized iron | M² | 819 | ¥ - | ¥ - | |||||
| A | A0031 | BA | 14 | Repair cracks on cement stucco wall by U-grooving and sealing with caulking compound | LM | 5,586 | ¥ - | ¥ - | |
| A | A0032 | BA | 15 | Make a hole (150 mm diameter ) through 200 mm thk reinforced concrete wall, floor and roof slab | EA | 9 | ¥ - | ¥ - | |
| A | A0033 | BA | 16 | Construct steel structure wall framing with LGS (JIS G 3350), including anticorrosive paint, common bolt and welding work | KG | 2,163 | ¥ - | ¥ - | |
| A | A0034 | BA | 17 | Construct steel structure with structural steel, including anticorrosive paint, high strength bolt and welding work | KG | 1,092 | ¥ - | ¥ - | |
| A | A0035 | BA | 18 | Construct reinforced concrete foundation simple column footing: |
footing: W700 x L700 x H300; column; W300 x L300 x H700;
including excavation, back filling, and frame work;
250mm thk base course, compacted crushed stone (C-40);
25mm thk cement bonded particle boards (JIS A 5404);
| steel bar: longitudinal bar D-16, hoop bar D-10 | EA | 28 | ¥ - | ¥ - | |
| A | A0036 | BA | 19 | Install concrete slab on earth D=150, including excavation, back filling, and frame work; |
150mmthk base course, compacted crushed stone (C-40) polyethylene sheet vapor barrior
| 25mm thk cement bonded particle boards (JIS A 5404) steel bar D-16 @200mm oc double | M² | 273 | ¥ - | ¥ - | |||||
| BB | ROOFING WORK | ||||||||
| A | A0037 | BB | 1 | Remove CFRPS roofing | M² | 4,074 | ¥ - | ¥ - | |
| A | A0038 | BB | 2 | Remove CGIS roofing and/or steel roof decks roofing | M² | 5,712 | ¥ - | ¥ - | |
| A | A0039 | BB | 3 | Remove steel batten seam roofing | M² | 63 | ¥ - | ¥ - | |
| A | A0040 | BB | 4 | Remove clay tile roofing | M² | 546 | ¥ - | ¥ - | |
| BB | 5 | Install 0.6 mm thk CGIS roofing | |||||||
| A | A0041 | BB | a | Pitch : 76.2 mm, height : 18 mm | M² | 9,219 | ¥ - | ¥ - | |
| A | A0042 | BB | b | Pitch : 130 mm, height : 36 mm | M² | 18,018 | ¥ - | ¥ - | |
| BB | 6 | Install CFRPS roofing, type : 28 FS | |||||||
| A | A0043 | BB | a | 2.0 mm thk, pitch : 76 mm | M² | 2,016 | ¥ - | ¥ - | |
| A | A0044 | BB | b | 1.5 mm thk, pitch : 130 mm | M² | 3,528 | ¥ - | ¥ - | |
| BB | 7 | Install 0.8 mm thk precoated galvanized iron roof decks, including tight frame, eaves sealing strip, ridge sealing strip ( 4 - lines / ridge ), caulking compound and apron, seamed type | |||||||
| A | A0045 | BB | a | Mountain height : approx. 90 mm | M² | 105 | ¥ - | ¥ - | |
| A | A0046 | BB | b | Mountain height : approx. 166 mm | M² | 315 | ¥ - | ¥ - | |
| A | A0047 | BB | 8 | Install prefabricated batten seam roofing, including flashings of ridge, hip, gable, eaves, valley, rise - up and around vent pipe, nosing, snow stop and sealing strip |
material : 0.5 mm thk precoated GIS finish : factory finish batten : 40 x 48 mm, o.c 420 mm snow stop : precoated sus, independent type, o.c 420 mm
| note : one continuous sheet from ridge to eave | M² | 63 | ¥ - | ¥ - | |
| A | A0048 | BB | 9 | Install prefabricated flat seam roofing, including flashings of ridge, hip, gable, eaves, valley, rise - up, around vent pipe and snow stop |
material : 0.5 mm thk precoated GIS finish : factory finish effective width : 315 mm height : 20 mm
| snow stop : precoated sus, independent type, o.c 420 mm | M² | 756 | ¥ - | ¥ - | |||||
| A | A0049 | BB | 10 | Replace caulking compound, including bond breaker and back-up material | LM | 8,127 | ¥ - | ¥ - | |
| A | A0050 | BB | 11 | Replace fastener set of roofing and siding with sus fastener set | EA | 17,409 | ¥ - | ¥ - | |
| A | A0051 | BB | 12 | Replace roofing felt with asphalt roofing felt | M² | 4,137 | ¥ - | ¥ - | |
| A | A0052 | BB | 13 | Replace wood roof sheathing board with 21 mm thk wood board | M² | 84 | ¥ - | ¥ - | |
| A | A0053 | BB | 14 | Replace wood roof sheathing board with 15 mm thk waterproof plywood panel, type -1 | M² | 2,121 | ¥ - | ¥ - | |
| A | A0054 | BB | 15 | Remove cement bonded particle roof sheathing board, 25 mm thk | M² | 126 | ¥ - | ¥ - | |
| A | A0055 | BB | 16 | Install cement bonded flake board (JIS A5404, HF type), non-combustible and hard type, 25 mm thk | M² | 126 | ¥ - | ¥ - | |
| BB | 17 | Replace wood purlin with wood lumber, preservative treated, including M 12 mm steel tie bar in center, halving joint | |||||||
| A | A0056 | BB | a | Size : 120 x 180 mm | LM | 294 | ¥ - | ¥ - | |
| A | A0057 | BB | b | Size : 150 x 150 mm | LM | 588 | ¥ - | ¥ - | |
| A | A0058 | BB | c | Size : 120 x 120 mm | LM | 1,302 | ¥ - | ¥ - | |
| A | A0059 | BB | d | Size : 90 x 90 mm | LM | 1,281 | ¥ - | ¥ - | |
| A | A0060 | BB | 18 | Replace wood rafter with 45 x 55 mm wood lumber, o.c 455 mm | LM | 1,491 | ¥ - | ¥ - | |
| A | A0061 | BB | 19 | Replace wood ridge capping, gable and fascia board with 21 x 240 mm wood board | LM | 1,281 | ¥ - | ¥ - | |
| A | A0062 | BB | 20 | Replace cement mortar surfaced wood gable, fascia and plancier with 12 mm thk waterproof plywood, type -1 | M² | 84 | ¥ - | ¥ - | |
| A | A0063 | BB | 21 | Replace plancier with 6 mm thk fiberglass cement board, asbestos free | M² | 126 | ¥ - | ¥ - | |
| A | A0064 | BB | 22 | Replace sealing strip with poly-urethane sealing strip | LM | 6,888 | ¥ - | ¥ - | |
| A | A0065 | BB | 23 | Replace ridge, gable and fascia flashings with 0.6 mm thk precoated GIS, including wood nailing block, flat lock seam joint, folding edges | M² | 3,843 | ¥ - | ¥ - | |
| BB | 24 | Replace eaves gutter with PVC gutter, including galvanized iron strap hanger, o.c 450 mm | |||||||
| A | A0066 | BB | a | Round Type : 120mm dia | LM | 399 | ¥ - | ¥ - | |
| A | A0067 | BB | b | Rectangular Type : 120 x 120mm | LM | 189 | ¥ - | ¥ - | |
| A | A0068 | BB | c | Rectangular Type : 150 x 150mm | LM | 1,008 | ¥ - | ¥ - | |
| A | A0069 | BB | d | Rectangular Type : 200 x 165mm | LM | 903 | ¥ - | ¥ - | |
| BB | 25 | Replace downspouts with PVC downspouts, including leader head, shoe and galvanized iron strap, o.c 450mm | |||||||
| A | A0070 | BB | a | 90mm dia | LM | 357 | ¥ - | ¥ - | |
| A | A0071 | BB | b | 120mm dia | LM | 105 | ¥ - | ¥ - | |
| A | A0072 | BB | c | VU 100 (114mm dia x 3.1mm thk) | LM | 2,121 | ¥ - | ¥ - | |
| A | A0073 | BB | d | VU 125 (140mm dia x 4.1mm thk) | LM | 714 | ¥ - | ¥ - | |
| BB | 26 | Replace underground storm - water drain pipes at 450 mm deep with PVC pipes, including excavation and backfilling work | |||||||
| A | A0074 | BB | a | VP 100 ( 114 mm dia x 6.6 mm thk ) | LM | 147 | ¥ - | ¥ - | |
| A | A0075 | BB | b | VP 125 ( 140 mm dia x 7.0 mm thk ) | LM | 63 | ¥ - | ¥ - | |
| A | A0076 | BB | 27 | Replace catch basin with precast concrete catch basin, 300 x 300 x 600 mm, including excavation and backfilling work | EA | 3 | ¥ - | ¥ - | |
| BB | 28 | Replace multi - layered steel valley gutter with new gutter, including plastic drain and 13 mm thk wood sheathing board |
linear width : 1200 mm end : YACHIYOGAESHI (or equal) with rivet and caulking note : one continuous sheet between expansion joint
| A | A0077 | BB | a | 0.5 mm thk precoated garubarium iron sheet gutter | LM | 861 | ¥ - | ¥ - |
| A | A0078 | BB | b | 1.3 mm thk PVC resin overlayed steel gutter with 0.5 mm thk steel core | LM | 777 | ¥ - | ¥ - |
| A | A0079 | BB | 29 | Replace snow guard with L - 40 x 40 x 3mm, sus | LM | 1,281 | ¥ - | ¥ - |
| A | A0080 | BB | 30 | Replace tie-down ring ( MARUKAN ) on ridge or gable, 19 mm diameter stainless steel with bracket and fastener | EA | 7 | ¥ - | ¥ - |
| BB | 31 | Replace roof ventilator with prefabricated roof ventilator set ( natural draft type ), including sus bird screen on top and bottom, painted finish | ||||||
| A | A0081 | BB | a | Head dia : 2400 mm, 1.0 mm thk, approx. weight : 352 kg | EA | 7 | ¥ - | ¥ - |
| A | A0082 | BB | b | Head dia : 3000 mm, 1.0 mm thk, approx. weight : 450 kg | EA | 21 | ¥ - | ¥ - |
| A | A0083 | BB | 32 | Remove and reinstall smoke detector and lighting fixture, including wiring and conduit pipe | EA | 42 | ¥ - | ¥ - |
| A | A0084 | BB | 33 | Replace plastic cover of skylight units on the roof with translucent FRP cover ( dome type ), including packing and fastener |
size : 1,700 long x 610 wide x 120 high mm
| thk : 2 mm | EA | 21 | ¥ - | ¥ - | |||||
| BB | 34 | Replace plastic cover of skylight units on the roof with translucent acrylic resin plastic cover (dome type), including packing and fastener | |||||||
| A | A0085 | BB | a | Size : 900 x 900 mm, 3 mm thk | EA | 3 | ¥ - | ¥ - | |
| A | A0086 | BB | b | Size : 1200 x 1200 mm, 4 mm thk | EA | 3 | ¥ - | ¥ - | |
| A | A0087 | BB | 35 | Replace skylight units on the roof with pre-fabricated skylight units, including anchor, cement mortar and caulking compound work |
type : fixed type cover : min. 3 mm thk translucent acrylic resin plastic, dome type glass : 6.8 mm thk wired glass frame : aluminum flashing : 100 mm wide aluminum note : fireproof
| size : 1300 x 1300 mm | UNIT | 3 | ¥ - | ¥ - | |
| A | A0088 | BB | 36 | Replace skylight units on the roof with pre-fabricated skylight units, including anchor, cement mortar, caulking compound, wire casing, wire and operation box work |
type : smoke eliminating, manual operation cover : min. 3 mm thk translucent acrylic resin plastic, dome type glass : 6.8 mm thk wired glass frame : aluminum flashing : 100 mm wide aluminum note : fireproof
| size : 1300 x 1300 mm | UNIT | 7 | ¥ - | ¥ - | |
| A | A0089 | BB | 37 | Replace skylight units on the roof with pre-fabricated skylight units, including anchor, cement mortar, caulking compound, wire casing, wire, electric wire and operation box work |
type : smoke eliminating, electric-motor-operated cover : min. 3 mm thk translucent acrylic resin plastic, dome type glass : 6.8 mm thk wired glass frame : aluminum flashing : 100 mm wide aluminum note : fireproof motor : AC 100V, 4A
| size : 1300 x 1300 mm | UNIT | 3 | ¥ - | ¥ - | |||||
| BC | WATERPROOFING WORK | ||||||||
| A | A0090 | BC | 1 | Remove protection concrete on built-up roofing | M² | 21 | ¥ - | ¥ - | |
| A | A0091 | BC | 2 | Remove gravel on built-up roofing | M² | 399 | ¥ - | ¥ - | |
| A | A0092 | BC | 3 | Remove built-up roofing, insulation board, metal coping, flashing and wood gravel stop | M² | 3,717 | ¥ - | ¥ - | |
| A | A0093 | BC | 4 | Remove built - up roofing, metal coping, flashing and wood gravel stop | M² | 19,635 | ¥ - | ¥ - | |
| A | A0094 | BC | 5 | Remove leveling cement mortar | M² | 735 | ¥ - | ¥ - | |
| A | A0095 | BC | 6 | Remove precast concrete coping | LM | 588 | ¥ - | ¥ - | |
| A | A0096 | BC | 7 | Remove polyurethane waterproof roof coating | M² | 3,528 | ¥ - | ¥ - | |
| A | A0097 | BC | 8 | Remove reinforced concrete foundation | CM | 13 | ¥ - | ¥ - | |
| A | A0098 | BC | 9 | Remove concrete base on built - up roofing and reinstall in place, such as pipe support and antenna base, etc | EA | 19 | ¥ - | ¥ - | |
| A | A0099 | BC | 10 | Raise - up piping system on built - up roofing with support and restore in place | M² | 189 | ¥ - | ¥ - | |
| A | A0100 | BC | 11 | Repair concrete cracks more than 1 mm wide by U - grooving and sealing with synthetic rubber asphalt sealing compound | LM | 3,570 | ¥ - | ¥ - | |
| A | A0101 | BC | 12 | Replace asphalt sealing compound along expansion joint with synthetic rubber asphalt sealing compound | LM | 525 | ¥ - | ¥ - | |
| A | A0102 | BC | 13 | Replace 120 x 120 mm wood gravel stop with M10 mm expansion anchor, o.c 450 mm | LM | 21 | ¥ - | ¥ - | |
| A | A0103 | BC | 14 | Replace roof drain with cast iron roof drain, including repair base around roof drain with cement mortar | EA | 210 | ¥ - | ¥ - | |
| A | A0104 | BC | 15 | Install sus air vent |
type : one vapor relief type
| capacity : covered 90 sm / ea | EA | 294 | ¥ - | ¥ - | |||||
| A | A0105 | BC | 16 | Install 200 mm high base flashing around vent stack, including 1.0 x 13 mm sus band with fastener | EA | 11 | ¥ - | ¥ - | |
| A | A0106 | BC | 17 | Install rigid polyurethane foam cant strip, 70 x 70 mm | LM | 735 | ¥ - | ¥ - | |
| A | A0107 | BC | 18 | Install aluminum edge strip, including asphalt sealing compound, L - 1.6 x 10 x 40 mm | LM | 1,617 | ¥ - | ¥ - | |
| A | A0108 | BC | 19 | Install aluminum cap flashing with rubber packing on edge strip, including asphalt sealing compound, 1.4 x 20 x 82 mm | LM | 903 | ¥ - | ¥ - | |
| BC | 20 | Install channel shape of aluminum coping, including corner, joint plate, strap anchor plate and asphalt sealing compound | |||||||
| A | A0109 | BC | a | [ - 2.0 x 75 x 200 x 55 mm | LM | 399 | ¥ - | ¥ - | |
| A | A0110 | BC | b | [ - 2.2 x 75 x 250 x 55 mm | LM | 2,877 | ¥ - | ¥ - | |
| A | A0111 | BC | 21 | Install leveling cement mortar, minimum 25 mm thk | LM | 6,237 | ¥ - | ¥ - | |
| A | A0112 | BC | 22 | Install rigid polyurethane foam insulation board |
density : 37 kg / cm finish : fiberglass textile finish 50 mm thk, thermal conductivity of the heat :
| 0.0095 Kcal / m.h.c. | M² | 2,058 | ¥ - | ¥ - | |||||
| A | A0113 | BC | 23 | Apply asphalt primer, 0.3 liter / sm | M² | 23,100 | ¥ - | ¥ - | |
| A | A0114 | BC | 24 | Apply modified bitumen membrane base sheet, self - adhesive type, 2.0 mm thk, 2.6 kg/sm | M² | 23,100 | ¥ - | ¥ - | |
| A | A0115 | BC | 25 | Apply modified bitumen membrane ply sheet, 4.0 mm thk, 4.1 kg/sm | M² | 22,911 | ¥ - | ¥ - | |
| A | A0116 | BC | 26 | Apply modified bitumen membrane cap sheet with mineral surface, 4.5 mm thk, 4.5 kg/sm | M² | 23,037 | ¥ - | ¥ - | |
| A | A0117 | BC | 27 | Apply 3 coats of polyurethane waterproof roof coating |
1st coat : primer, 0.2 kg/sm 2nd coat : polyurethane, 2.0 kg/sm 3rd coat : polyurethane, 1.0 kg/sm 4 th coat : polyurethane, 0.2 kg/sm
| product; OSTL-6S, Tajima roofing Inc., or equivalent | M² | 1,197 | ¥ - | ¥ - | |
| A | A0118 | BC | 28 | Apply 4 coats of polyurethane waterproof roof coating |
1st coat : primer, 0.2 kg / sm 2nd coat : polyurethane, 0.3 kg / sm 3rd coat : glassfiber mesh : 42 g / sm 4th coat : polyurethane, 1.7 kg / sm 5th coat : polyurethane, 1.5 kg / sm 6th coat : polyurethane, 0.2 kg / sm specific gravity of polyurethane : 1.2
| product; OSTM-3S, Tajima roofing Inc., or equivalent | M² | 1,008 | ¥ - | ¥ - | |||||
| A | A0119 | BC | 29 | Install reinforced concrete foundation for equipment, including 6ea - M12 mm anchor bolt | CM | 26 | ¥ - | ¥ - | |
| A | A0120 | BC | 30 | Replace wood gravel stop (2 layers of 90 x 150 mm), including 50 mm thk epoxy resin cement mortar base and M12 mm capsule anchor, o.c 300 mm | LM | 567 | ¥ - | ¥ - | |
| BD | DOOR AND WINDOW WORK | ||||||||
| BD | 1 | Remove metal swinging door in reinforced concrete wall, including frame, trim and threshold | |||||||
| A | A0121 | BD | a | Single swinging door | EA | 9 | ¥ - | ¥ - | |
| A | A0122 | BD | b | Double swinging door | EA | 17 | ¥ - | ¥ - | |
| BD | 2 | Remove metal swinging door in wall other than reinforced concrete wall, including frame, trim and threshold | |||||||
| A | A0123 | BD | a | Single swinging door | EA | 11 | ¥ - | ¥ - | |
| A | A0124 | BD | b | Double swinging door | EA | 3 | ¥ - | ¥ - | |
| BD | 3 | Install aluminum door, including frame, trim, threshold, finish hardwares and caulking compound |
door thk : 30 mm frame depth : 70 mm threshold : 2.0 mm thk sus face panel : 0.8 mm thk finish hardware : cylinder lock set, thumb turn, door closer with 90 degree stop, hinges, door stop and hook holder and flush bolt set, etc.
finish : factory finish
| A | A0125 | BD | a | Single swinging flush door, size : 900 x 2100 mm | EA | 9 | ¥ - | ¥ - |
| A | A0126 | BD | b | Single swinging half glass door, size: 900 x 2100 mm, glass size: 5 x 600 x 600 mm, tempered | EA | 3 | ¥ - | ¥ - |
| A | A0127 | BD | c | Double swinging flush door, size : 1800 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| A | A0128 | BD | d | Double swinging half glass door. size: 1800 x 2100 mm; glass size: 5 x 600 x 600 mm, tempered | EA | 3 | ¥ - | ¥ - |
| BD | 4 | Install heavy-weight steel door, including frame, trim, threshold, finish hardwares and caulking compound |
door thk : 45 mm frame thk : 2.3 mm threshold : 2.0 mm thk sus face panel : 1.6 mm thk finish hardware : cylinder lock set, thumb turn, door closer with 90 degree stop, hinges, door stop and hook holder and flush bolt set, etc finish : baked enamel paint, factory finish
| A | A0129 | BD | a | Single swinging flush door: size : 900 x 2100 mm | EA | 11 | ¥ - | ¥ - |
| A | A0130 | BD | b | Double swinging flush door: size : 1800 x 2100 mm | EA | 32 | ¥ - | ¥ - |
| A | A0131 | BD | 5 | Remove metal window in reinforced concrete wall, window size : 1500 x 1200 mm | EA | 19 | ¥ - | ¥ - |
| A | A0132 | BD | 6 | Remove metal window in wall other than reinforced concrete wall, window size: 1500 x 1200 mm | EA | 179 | ¥ - | ¥ - |
| BD | 7 | Install aluminum sliding window, including aluminum flashing, window board and trim, 70 mm frame wide | ||||||
| A | A0133 | BD | a | Size : 1500 x 1200 mm | EA | 74 | ¥ - | ¥ - |
| A | A0134 | BD | b | Size : 1800 x 1200 mm | EA | 47 | ¥ - | ¥ - |
| BD | 8 | Replace aluminum screen window with sus insect screen | ||||||
| A | A0135 | BD | a | Size : 1500 x 1200 mm | EA | 32 | ¥ - | ¥ - |
| A | A0136 | BD | b | Size : 1800 x 1200 mm | EA | 3 | ¥ - | ¥ - |
| BD | 9 | Replace glass pane , including putty or sealant or gasket | ||||||
| A | A0137 | BD | a | 3 mm thk sheet glass pane ( FL 3 ) | M² | 126 | ¥ - | ¥ - |
| A | A0138 | BD | b | 5 mm thk tempered glass pane ( FL 5 ) | M² | 21 | ¥ - | ¥ - |
| A | A0139 | BD | c | 6 mm thk laminated glass pane ( FL 3 +FL 3 ) | M² | 168 | ¥ - | ¥ - |
| A | A0140 | BD | d | 6.8 mm thk wired glass pane ( FW 6.8 ) | M² | 21 | ¥ - | ¥ - |
| A | A0141 | BD | e | 4 mm thk patterned glass pane ( F 4 ) | M² | 21 | ¥ - | ¥ - |
| A | A0142 | BD | f | 12mm thk double glazing glass (FL3+ Air 6+ FL3) | M² | 21 | ¥ - | ¥ - |
| A | A0143 | BD | 10 | Fill cement mortar along frames of door and window, between wall and frames | LM | 105 | ¥ - | ¥ - |
| BD | 11 | Install alminum blast resistant window (protection level: low) which comply with UFC 4-010-01 (ATFP), with aluminum flashing, window board and trim, including transportation and installation fee, shops drawings, structural blast calculations, and anchor caluculation, window type: sliding, size: approx. 66"wide x 72"high, product: Graham Architectural Products, or equivalent | ||||||
| A | A0144 | BD | a | Glass: 1/4" thick laminated glass | EA | 28 | ¥ - | ¥ - |
| A | A0145 | BD | b | Sealed insulated glass unit (1/4" thick laminated glasses separated by a 1/4" thick air space) | EA | 28 | ¥ - | ¥ - |
| C | MAINTENANCE OF BUILDING INTERIOR | |||||||
| A | A0146 | C | 1 | Apply surface preparation, 1 coat of primer and 2 coats of emulsion paints (JIS K 5663, Type-2) on gypsum board, cement mortar and gypsum plaster surfaces | M² | 49,350 | ¥ - | ¥ - |
| A | A0147 | C | 2 | Apply surface preparation, 1 coat of primer and 2 coats of emulsion paints (JIS K 5572, Type-1) on steel surfaces, including structural frame surface | M² | 5,586 | ¥ - | ¥ - |
| A | A0148 | C | 3 | Apply surface preparation, 1 coat of primer and 2 coats of textured coating (JIS A 6909, Type-E) on cement stucco surfaces | M² | 105 | ¥ - | ¥ - |
| A | A0149 | C | 4 | Apply surface preparation, 1 coat of primer and 2 coats of ready mixed paints (JIS K 5516) on wood surfaces | M² | 2,079 | ¥ - | ¥ - |
| A | A0150 | C | 5 | Apply surface preparation, 2 coats of varnish urethane resin (JASS 18 M-502) on wood surfaces, including stain | M² | 735 | ¥ - | ¥ - |
| A | A0151 | C | 6 | Apply surface preparation, 1 coat of primer and 2 coats of aluminum paint (JIS K 5492) on steel surfaces | M² | 210 | ¥ - | ¥ - |
| A | A0152 | C | 7 | Apply surface preparation and paint safety markings - diagonal contrasting colors, 100 mm |
wide black and yellow stripes - with 1 coat of primer and 2 coats of urethane resin emulsion
| paint on concrete surface, waterproof and slip resistant | M² | 1,092 | ¥ - | ¥ - | |||||
| A | A0153 | C | 8 | Apply surface preparation and paint safety markings - diagonal contrasting colors, 100 mm wide black and yellow stripes - with 1 coat of primer and 2 coats of enamel paint ( JIS K 5572, type-2) on steel surface, such as wheel guard post and wall around vehicle entrance, etc | M² | 63 | ¥ - | ¥ - | |
| A | A0154 | C | 9 | Replace caulking compound, including bond breaker and back-up material | LM | 1,806 | ¥ - | ¥ - | |
| A | A0155 | C | 10 | Remove floor wax and apply 2 coats of floor wax on vinyl composition floor tile and vinyl floor sheet, buff finish by polisher | M² | 819 | ¥ - | ¥ - | |
| D | REPAIR/CONSTRUCTION OF BUILDING INTERIOR | ||||||||
| DA | FLOORING WORK | ||||||||
| A | A0156 | DA | 1 | Remove asbestos free vinyl composition tile and vinyl sheet, including adhesive | M² | 3,087 | ¥ - | ¥ - | |
| A | A0157 | DA | 2 | Remove asbestos free broadloom carpet and carpet tile, including adhesive | M² | 10,626 | ¥ - | ¥ - | |
| A | A0158 | DA | 3 | Replace leveling cement mortar, 25 mm thk | M² | 9,891 | ¥ - | ¥ - | |
| A | A0159 | DA | 4 | Make a floor level with self-leveling gypsum plaster, 15 mm thk | M² | 7,098 | ¥ - | ¥ - | |
| A | A0160 | DA | 5 | Install vinyl composition floor tile, 3.0 X 300 X 300 mm, product: Matico V, Toli Corporation, or equivalent | M² | 8,883 | ¥ - | ¥ - | |
| A | A0161 | DA | 6 | Install PVC floor sheet, including welded along joint, antistatic floor sheet, 2.0 mm thk, product: Taiden-boushi floorlume, Toli Corporation, or equivalent | M² | 819 | ¥ - | ¥ - | |
| A | A0162 | DA | 7 | Replace ceramic floor tile, 100 x 100 mm product: Acordi U, Inax Corporation, or equivalent | M² | 63 | ¥ - | ¥ - | |
| A | A0163 | DA | 8 | Replace stainless steel edge and joint molding for carpet | LM | 2,604 | ¥ - | ¥ - | |
| DA | 9 | Install tile carpet, flame proof, size: 500 x 500 x 6.5 mm, static control: less than 1.0 kv | |||||||
| A | A0164 | DA | a | Product: NT 350 basic, Sangetsu Co., Ltd., or equivalent | M² | 2,079 | ¥ - | ¥ - | |
| A | A0165 | DA | b | Product : GX 200, Toli Co., Ltd. or equivalent | M² | 21 | ¥ - | ¥ - | |
| DA | 10 | Install broadloom carpet, flame proof , type: tufted | |||||||
| A | A0166 | DA | a | Thickness: 6.5 mm in total, static control: less than 3.0 kv, product: Sunlime, Sangetsu Co., Ltd., or equivalent | M² | 2,331 | ¥ - | ¥ - | |
| A | A0167 | DA | b | Thickness: 6.0 mm in total, static control: less than 1.0 kv, product: Grace Toli Corporation, or equivalent | M² | 21 | ¥ - | ¥ - | |
| A | A0168 | DA | 11 | Install broadloom carpet, flameproof, type: wilton, thk: 9 mm, static control: less than 1.0 kv, product: New illumination, Toli Co., Ltd. or equal | M² | 21 | ¥ - | ¥ - | |
| A | A0169 | DA | 12 | Install fiber felt underlayment for carpet, 8 mm thk, product : Haikusshon, Kansai Felt Fabric Co., Ltd. or equal | M² | 84 | ¥ - | ¥ - | |
| A | A0170 | DA | 13 | Reinforce concrete floor slab of 2nd floor with applying steel frame below floor slab and between girder of floor slab |
steel frame: H-350 x 175 x 7 x 11 mm end plate: 350x350x12 mm expansion anchor: 4-M16 mm/end plate frame length: 6000mm
| structure: continuous fillet welded structure | EA | 3 | ¥ - | ¥ - | |||||
| A | A0171 | DA | 14 | Remove exist coating on concrete floor, such as urethane and epoxy resin coating, etc | M² | 3,570 | ¥ - | ¥ - | |
| A | A0172 | DA | 15 | Apply hardner on the concrere floor surface product: Hardner S, ABC Trading Co., Ltd. or equivalent | M² | 21 | ¥ - | ¥ - | |
| A | A0173 | DA | 16 | Apply surface preparation, 1 coat of primer and 2 coats of epoxy resin coating on concrete floor surface, chemicalproof, waterproof and sip resistant, 0.8 mm thk, product: Kemicreat E, Coating method, ABC Trading Co., Ltd., or equivalent | M² | 105 | ¥ - | ¥ - | |
| DA | 17 | Apply surface preparation, 1 coat of primer, 1 coat of epoxy resin coating with aggregate, | |||||||
| A | A0174 | DA | a | And 2 coats of epoxy resin coating on concrete floor surface, slipperyproof and waterproof, 1.2 mm thk, product: Kemicreat E, Boukatsu method, ABC Trading Co., Ltd., or equivalent | M² | 168 | ¥ - | ¥ - | |
| A | A0175 | DA | b | And 1 coat of epoxy resin coating on concrete floor surface, durableproof, waterproof and sip resistant, 2.0 mm thk, product: Kemicreat E, Paste method, ABC Trading Co., Ltd., or equivalent | M² | 7,224 | ¥ - | ¥ - | |
| A | A0176 | DA | 18 | Apply epoxy-resin coating on the concrete floor surface. Surface preparation: apply 2 coats of primer, apply 1 coat of epoxy-resin with aggregate, apply 2 coats of wax. Product: Smooth Coat, ABC Trading Co., Ltd. or equivalent | M² | 21 | ¥ - | ¥ - | |
| DB | WALL WORK | ||||||||
| A | A0177 | DB | 1 | Replace vinyl cove base, 100 mm high | |||||
| Product: Soft Habaki, Toli corporation, or equivalent | LM | 10,122 | ¥ - | ¥ - | |||||
| A | A0178 | DB | 2 | Replace hardwood baseboard, 18 x 100 mm. | |||||
| Product: Sunment, Mihashi Co.Ltd., or equivalent | LM | 483 | ¥ - | ¥ - | |||||
| A | A0179 | DB | 3 | Replace wall framing system with steel furrings, framing system, including runner, stud (o.c 450 mm) and spacer. Size: W-75 (stud: C-75 x 45 x 0.8 mm) | M² | 210 | ¥ - | ¥ - | |
| A | A0180 | DB | 4 | Replace glassfiber insulation. Aluminum film and asphalt craft paper surfaces. 50 mm thk, 24 kg/cm | M² | 2,184 | ¥ - | ¥ - | |
| A | A0181 | DB | 5 | Install glassfiber insulation board on wall and ceiling with pin ( o.c 455 mm ) and adhesive, exposed type. 50 mm thk, 24 kg/cm, glass cloth finish. Apply casing bead to edge and corners | M² | 63 | ¥ - | ¥ - | |
| A | A0182 | DB | 6 | Replace gypsum wallboard, 12.5 mm thk | M² | 735 | ¥ - | ¥ - | |
| A | A0183 | DB | 7 | Replace fiber reinforced cement board, 6 mm thk, asbestos free | M² | 378 | ¥ - | ¥ - | |
| A | A0184 | DB | 8 | Replace cement mortar or gypsum plaster wall in 3-coats, 20 mm thk | M² | 672 | ¥ - | ¥ - | |
| A | A0185 | DB | 9 | Replace external aluminum corner guard, L - 1.5 x 30 x 30 mm | LM | 84 | ¥ - | ¥ - | |
| A | A0186 | DB | 10 | Replace ceramic wall tile, including cove base 100 x 100 mm, product: Misty Neo, Inax Corporation, or equivalent | M² | 105 | ¥ - | ¥ - | |
| A | A0187 | DB | 11 | Repair cracks on gypsumboard, gypsum plaster and cement mortar surfaces by U - grooving and sealing with caulking compound | LM | 2,247 | ¥ - | ¥ - | |
| A | A0188 | DB | 12 | Replace venetian blind with aluminum venetian blind, 25 mm wide slat. Product: Silky, Tachikawa Corporation, or equivalent | M² | 105 | ¥ - | ¥ - | |
| A | A0189 | DB | 13 | Replace PVC laminated glass fiber vane vertical blind, slat: 0.3 x 80 mm, flame-proof treated. Product: Mint, Tachikawa Corp., or equivalent | M² | 21 | ¥ - | ¥ - | |
| A | A0190 | DB | 14 | Remove reinforced concrete wall and reinforced concrete block wall, including making a door and window opening work | CM | 13 | ¥ - | ¥ - | |
| A | A0191 | DB | 15 | Install reinforced concrete block wall |
material: 150 mm thk, type - c fill cement mortar in all holes vertical bar: D-13 mm, o.c 200 mm horizontal bar: D-13 mm, o.c 600 mm
| expansion anchor, welded to steel bar | M² | 21 | ¥ - | ¥ - | |
| A | A0192 | DB | 16 | Install 150 mm thk reinforced concrete wall, including steel bars and expansion anchor, welded to steel bar |
vertical bars : D13 mm, o.c 225 mm
| horizontal bars : D13 mm, o.c 225 mm | M² | 168 | ¥ - | ¥ - | |||||
| A | A0193 | DB | 17 | Install forms | M² | 63 | ¥ - | ¥ - | |
| A | A0194 | DB | 18 | Curing and patching for concrete surface | M² | 105 | ¥ - | ¥ - | |
| A | A0195 | DB | 19 | Replace steel framed chain link wire fabric security wall, including door |
stud and beam : square pipe, 100 x 100 x 3.2 mm, o.c 1200 mm top and base frame : rectangular pipe - 100 x 50 x 3.2 mm with M12 mm expansion anchor, o.c 450 mm chain link : 4.0 mm dia. x 40 mm mesh opening, welded to steel frame through
4.0 mm dia. weaving wire door : single swinging door, 915 x 2100 mm frame and muntin: square pipe - 75 x 75 x 3.2 mm finish hardware: 3ea-sus hinges, 16 mm dia. steel door bolt and 2ea - door pull
| structure : welded steel structure | M² | 63 | ¥ - | ¥ - | |||||
| A | A0196 | DB | 20 | Replace vinyl wall covering, fireproof, smokeproof and mildew proof. Product: WVP1092, Toli Co., Ltd. or equal | M² | 273 | ¥ - | ¥ - | |
| DC | CEILING WORK | ||||||||
| A | A0197 | DC | 1 | Replace steel furrings ceiling system |
hanger and anchor : 9 mm dia, o.c 900 mm runner : [ -1.6 x 38 x 12 mm, o.c 900 mm furrings : [ - 0.5 x 25 x 25 mm, o.c 303 mm
| [ - 0.5 x 50 x 25 mm, o.c 909 mm | M² | 441 | ¥ - | ¥ - | |||||
| DC | 2 | Replace gypsum ceiling board | |||||||
| A | A0198 | DC | a | 9.5 mm thk for sheathing | M² | 525 | ¥ - | ¥ - | |
| A | A0199 | DC | b | 12.5 mm thk for finish | M² | 1,029 | ¥ - | ¥ - | |
| A | A0200 | DC | 3 | Replace acoustic rockwool tile, 9 x 300 x 600 mm. Product: Soraton, Yoshino Gypsum Co., Ltd., or equivalent | M² | 777 | ¥ - | ¥ - | |
| A | A0201 | DC | 4 | Replace fiber reinforced cement board, 6 mm thk, asbestos free | M² | 63 | ¥ - | ¥ - | |
| A | A0202 | DC | 5 | Replace aluminum ceiling edge molding | LM | 546 | ¥ - | ¥ - | |
| A | A0203 | DC | 6 | Replace aluminum ceiling access, acoustic rockwool tile finish, size: 600 x 600 mm | EA | 28 | ¥ - | ¥ - | |
| A | A0204 | DC | 7 | Repair cracks on gypsum plaster and cement mortar surfaces by U-grooving and sealing with caulking compound | LM | 714 | ¥ - | ¥ - | |
| A | A0205 | DC | 8 | Install aluminum spandrel ceiling with aluminum edge molding, color coated aluminum; t=0.6mm, W120mm x H15mm, ribbed shape @15mm | M² | 84 | ¥ - | ¥ - | |
| DD | DOOR WORK | ||||||||
| DD | 1 | Remove wood swinging door, including frame | |||||||
| A | A0206 | DD | a | Single swinging door | EA | 3 | ¥ - | ¥ - | |
| A | A0207 | DD | b | Double swinging door | EA | 3 | ¥ - | ¥ - | |
| DD | 2 | Remove steel swinging door in reinforced concrete wall, including frame, trim & threshold | |||||||
| A | A0208 | DD | a | Single swinging door | EA | 3 | ¥ - | ¥ - | |
| A | A0209 | DD | b | Double swinging door | EA | 21 | ¥ - | ¥ - | |
| DD | 3 | Remove steel swinging door in wall other than reinforced concrete wall, including frame, trim & threshold | |||||||
| A | A0210 | DD | a | Single swinging door | EA | 3 | ¥ - | ¥ - | |
| A | A0211 | DD | b | Double swinging door | EA | 3 | ¥ - | ¥ - | |
| DD | 4 | Install wood door, including frame, trim and finish hardware |
door thickness: 40 mm face panel: plastic laminated plywood, 5.5 mm thk finish hardware: cylinder lock set, thumb turn, door closer with 90 degree stop, hinges, door stop & hook holder and flush bolt set, etc finish: varnish finish for frame and trim core: 25 mm thk fiberglass insulation, 24 kg / cm
| A | A0212 | DD | a | Single swinging flush door: size : 900 x 2100 mm | EA | 7 | ¥ - | ¥ - |
| A | A0213 | DD | b | Double swinging flush door: size : 1800 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| DD | 5 | Install light-weight steel door, including frame, trim, threshold and finish hardware |
door thickness: 45 mm frame thickness: 1.6 mm threshold: 2.0 mm thk, sus face panel: 0.8 mm thk finish hardware: cylinder lock set, thumb turn, door closer with 90 degree stop, hinges, door stop & hook holder, flush bolt set, etc finish: baked enamel paint (factory finish) core: 25 mm thk fiberglass insulation,
| A | A0214 | DD | a | Single swinging flush door. Size : 915 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| A | A0215 | DD | b | Double swinging flush door. Size : 1800 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| DD | 6 | Install semi-sound proof steel door, including frame, trim, threshold and finish hardware |
door thickness: 70 mm frame thickness : 2.3 mm threshold: 2.0 mm thk, sus face panel: 1.6 mm thk finish hardware : cremone locks, cylinder lock set with thumb turn, top pivot & floor hinge door closer, door stop & hook holder, flush bolt set, etc finish : baked enamel paint (factory finish) soundproof : grade - 2 fill rockwool (80 kg/cm) in door and frame
| A | A0216 | DD | a | Single swinging flush door. Size : 915 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| A | A0217 | DD | b | Double swinging flush door. Size: 1800 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| DD | 7 | Install sound proof steel door, including frame, trim, threshold and finish hardware |
door thickness: 70 mm frame thickness: 2.3 mm threshold: 2.0 mm thk, sus face panel: 1.6 mm thk finish hardware: gremone locks, cylinder lock set with thumb turn, top pivot & floor hinge door closer, door stop & hook holder, flush bolt set, etc finish: baked enamel paint (factory finish) soundproof: grade - 4 fill rockwool (80 kg/cm) in door and frame
| A | A0218 | DD | a | Single swinging flush door. Size : 915 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| A | A0219 | DD | b | Double swinging flush door. Size: 1800 x 2100 mm | EA | 3 | ¥ - | ¥ - |
| A | A0220 | DD | 8 | Fill cement mortar along door frame, between wall and door frame | LM | 126 | ¥ - | ¥ - |
| A | A0221 | DD | 9 | Replace film on window glass with polyester resin plastic film for solar control & safety (splashproof of glass), non-combustible, 75 micrometer thk | M² | 21 | ¥ - | ¥ - |
| A | A0222 | DD | 10 | Replace window operation system for inswinging/outswinging window, including |
operation box, casing and wire, operation: manual type - closing by handle and opening by push button
| window width: less than 6,000 mm | SET | 3 | ¥ - | ¥ - | |||||
| DD | 11 | Replace cylinder lock set with sus panic bolt set, by applying 1.6 mm thk sus sheets on both sides surface of door | |||||||
| A | A0223 | DD | a | For single swinging door | SET | 9 | ¥ - | ¥ - | |
| A | A0224 | DD | b | For double swinging door | SET | 17 | ¥ - | ¥ - | |
| DE | OTHER WORK | ||||||||
| A | A0225 | DE | 1 | Relocate tumbler switch, receptacle outlet, lighting fixture and fire detector to the place within 1 linear meter, including junction box, conduit pipe and wiring work | EA | 84 | ¥ - | ¥ - | |
| A | A0226 | DE | 2 | Conduct operation test of fire detector by qualified person | EA | 13 | ¥ - | ¥ - | |
| A | A0227 | DE | 3 | Apply common laborer to various work (removal and relocation work, etc) | DAY | 294 | ¥ - | ¥ - | |
| E | EXTERIOR ELECTRIC | ||||||||
| REPLACE POLE MOUNTED 1 PHASE TRANSFORMER SYSTEM (Sketch No. E-01) | |||||||||
| A | A0228 | EA | 1 | Transformer Capacity: 30 kVA | set | 5 | ¥ - | ¥ - | |
| A | A0229 | EA | 2 | Transformer Capacity: 50 kVA | set | 7 | ¥ - | ¥ - | |
| A | A0230 | EA | 3 | Transformer Capacity: 75 kVA | set | 11 | ¥ - | ¥ - | |
| A | A0231 | EA | 4 | Transformer Capacity: 100 kVA | set | 11 | ¥ - | ¥ - | |
| REPLACE POLE MOUNTED 3 PHASE TRANSFORMER SYSTEM (Sketch No. E-02) | |||||||||
| A | A0232 | EB | 5 | Transformer Capacity: 30 kVA | set | 5 | ¥ - | ¥ - | |
| A | A0233 | EB | 6 | Transformer Capacity: 50 kVA | set | 7 | ¥ - | ¥ - | |
| A | A0234 | EB | 7 | Transformer Capacity: 75 kVA | set | 11 | ¥ - | ¥ - | |
| A | A0235 | EB | 8 | Transformer Capacity: 100 kVA | set | 11 | ¥ - | ¥ - | |
| EC | REPLACE CUBICLE TYPE ELECTRICAL SUBSTATION SYSTEM (Sketch No. E-03) | ||||||||
| 3 Phase Transformer with LBS, Fuse and Secondary CT | |||||||||
| A | A0236 | EC | 9 | Transformer Capacity: 50 kVA | set | 5 | ¥ - | ¥ - | |
| A | A0237 | EC | 10 | Transformer Capacity: 75 kVA | set | 7 | ¥ - | ¥ - | |
| A | A0238 | EC | 11 | Transformer Capacity: 100 kVA | set | 11 | ¥ - | ¥ - | |
| A | A0239 | EC | 12 | Transformer Capacity: 150 kVA | set | 11 | ¥ - | ¥ - | |
| A | A0240 | EC | 13 | Transformer Capacity: 200 kVA | set | 5 | ¥ - | ¥ - | |
| 1 Phase Transformer with LBS, Fuse and Secondary CT | |||||||||
| A | A0241 | EC | 14 | Transformer Capacity: 50 kVA | set | 5 | ¥ - | ¥ - | |
| A | A0242 | EC | 15 | Transformer Capacity: 75 kVA | set | 7 | ¥ - | ¥ - | |
| A | A0243 | EC | 16 | Transformer Capacity: 100 kVA | set | 5 | ¥ - | ¥ - | |
| Low Voltage Multi-Digital Meter | |||||||||
| A | A0244 | EC | 17 | 3 Phase / 3 Wire system | set | 15 | ¥ - | ¥ - | |
| A | A0245 | EC | 18 | 3 Phase / 4 Wire system | set | 21 | ¥ - | ¥ - | |
| A | A0246 | EC | 19 | 1 Phase / 3 Wire system | set | 15 | ¥ - | ¥ - | |
| Other Electrical Substation Equipment | |||||||||
| A | A0247 | EC | 20 | 6.6kV VT and 6.9kV CT | set | 42 | ¥ - | ¥ - | |
| A | A0248 | EC | 21 | Load Break Switch (LBS), 7.2kV 200A | set | 42 | ¥ - | ¥ - | |
| A | A0249 | EC | 22 | Disconnecting Switch (DS), 7.2kV 200A | set | 63 | ¥ - | ¥ - | |
| A | A0250 | EC | 23 | 6kV 3Ph3W Multi-Digital Meter with CT and VT | set | 42 | ¥ - | ¥ - | |
| A | A0251 | EC | 24 | LA and Grounding System | set | 42 | ¥ - | ¥ - | |
| A | A0252 | EC | 25 | Operational Transformer (OP) 5kVA | set | 42 | ¥ - | ¥ - | |
| A | A0253 | EC | 26 | MCCB, 3P 600AF | ea | 21 | ¥ - | ¥ - | |
| A | A0254 | EC | 27 | MCCB, 3P 400AF | ea | 42 | ¥ - | ¥ - | |
| A | A0255 | EC | 28 | MCCB, 3P 225AF | ea | 63 | ¥ - | ¥ - | |
| A | A0256 | EC | 29 | MCCB, 3P-50AF ~ 100AF | ea | 105 | ¥ - | ¥ - | |
| TEST | |||||||||
| A | A0257 | EC | 30 | AC High Voltage Withstand Test | job | 42 | ¥ - | ¥ - | |
| ED | REPLACE CUBICLE SHED (Sketch No. E-04) | ||||||||
| A | A0258 | ED | 31 | Cubicle Housing | set | 42 | ¥ - | ¥ - | |
| A | A0259 | ED | 32 | Cubicle Repaint Work | m2 | 210 | ¥ - | ¥ - | |
| EE | REPLACE PAS SYSTEM (Sketch No. E-05) | ||||||||
| A | A0260 | EE | 33 | PAS System | set | 21 | ¥ - | ¥ - | |
| A | A0261 | EE | 34 | Grounding System | set | 21 | ¥ - | ¥ - | |
| A | A0262 | EE | 35 | 8.4kV Arrester (3 ea) | set | 21 | ¥ - | ¥ - | |
| EF | REPLACE 6KV 3 PHASE OVERHEAD LINES (Sketch No. E-06) | ||||||||
| A | A0263 | EF | 36 | Wire Size: 38 mm2 | m | 210 | ¥ - | ¥ - | |
| A | A0264 | EF | 37 | Wire Size: 60 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0265 | EF | 38 | Wire Size: 100 mm2 | m | 630 | ¥ - | ¥ - | |
| A | A0266 | EF | 39 | Insulators, Arm and Connectors | set | 42 | ¥ - | ¥ - | |
| EG | REPLACE 600V 3 PHASE OVERHEAD LINES (Sketch No. E-07) | ||||||||
| A | A0267 | EG | 40 | Wire Size: 14 mm2 | m | 840 | ¥ - | ¥ - | |
| A | A0268 | EG | 41 | Wire Size: 22 mm2 | m | 630 | ¥ - | ¥ - | |
| A | A0269 | EG | 42 | Wire Size: 38 mm2 | m | 630 | ¥ - | ¥ - | |
| A | A0270 | EG | 43 | Wire Size: 60 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0271 | EG | 44 | Wire Size: 100 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0272 | EG | 45 | Insulators, Arm and Connectors | set | 84 | ¥ - | ¥ - | |
| EH | REPLACE 600V 3 PHASE RO 1 PHASE SERVICE CONDUCTOR (Sketch No. E-08) | ||||||||
| A | A0273 | EH | 46 | Wire Size: 8 mm2 | m | 210 | ¥ - | ¥ - | |
| A | A0274 | EH | 47 | Wire Size: 14 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0275 | EH | 48 | Wire Size: 22 mm2 | m | 168 | ¥ - | ¥ - | |
| A | A0276 | EH | 49 | Wire Size: 38 mm2 | m | 105 | ¥ - | ¥ - | |
| A | A0277 | EH | 50 | Wire Size: 60 mm2 | m | 105 | ¥ - | ¥ - | |
| A | A0278 | EH | 51 | Insulators, Arm and Connectors | set | 126 | ¥ - | ¥ - | |
| EJ | REPLACE 6KV 3 PHASE UNDERGROUND WIRING (Sketch No. E-09) | ||||||||
| A | A0279 | EJ | 52 | Wire Size: 22 mm2 | m | 630 | ¥ - | ¥ - | |
| A | A0280 | EJ | 53 | Wire Size: 38 mm2 | m | 1,050 | ¥ - | ¥ - | |
| A | A0281 | EJ | 54 | Wire Size: 60 mm2 | m | 1,050 | ¥ - | ¥ - | |
| A | A0282 | EJ | 55 | Wire Size: 100 mm2 | m | 630 | ¥ - | ¥ - | |
| A | A0283 | EJ | 56 | Cable Marker | ea | 84 | ¥ - | ¥ - | |
| A | A0284 | EJ | 57 | DC High Voltage Withstand Test | job | 42 | ¥ - | ¥ - | |
| EK | REPLACE 600V 3 PHASE OR 1 PHASE UNDERGROUND WIRING (Sketch No. E-10) | ||||||||
| CVT Cable | |||||||||
| A | A0285 | EK | 58 | Wire Size: 8 mm2 | m | 2,100 | ¥ - | ¥ - | |
| A | A0286 | EK | 59 | Wire Size: 14 mm2 | m | 1,050 | ¥ - | ¥ - | |
| A | A0287 | EK | 60 | Wire Size: 22 mm2 | m | 1,050 | ¥ - | ¥ - | |
| A | A0288 | EK | 61 | Wire Size: 38 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0289 | EK | 62 | Wire Size: 60 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0290 | EK | 63 | Wire Size: 100 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0291 | EK | 64 | Low Voltage Cutout Switch | set | 105 | ¥ - | ¥ - | |
| CVQ Cable | |||||||||
| A | A0292 | EK | 65 | Wire Size: 8 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0293 | EK | 66 | Wire Size: 14 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0294 | EK | 67 | Wire Size: 22 mm2 | m | 840 | ¥ - | ¥ - | |
| A | A0295 | EK | 68 | Wire Size: 38 mm2 | m | 840 | ¥ - | ¥ - | |
| A | A0296 | EK | 69 | Wire Size: 60 mm2 | m | 420 | ¥ - | ¥ - | |
| A | A0297 | EK | 70 | Wire Size: 100 mm2 | m | 420 | ¥ - | ¥ - | |
| Spare Conduit with Pull Wire | |||||||||
| A | A0298 | EK | 71 | PE 54 | m | 420 | ¥ - | ¥ - | |
| A | A0299 | EK | 72 | PE 104 | m | 420 | ¥ - | ¥ - | |
| A | A0300 | EK | 73 | FEP 50 | m | 420 | ¥ - | ¥ - | |
| A | A0301 | EK | 74 | FEP 100 | m | 420 | ¥ - | ¥ - | |
| EL | REPLACE CONCRETE POLE (Sketch No. E-11) | ||||||||
| A | A0302 | EL | 75 | 13m-19cm-5.0kN Pole | set | 21 | ¥ - | ¥ - | |
| A | A0303 | EL | 76 | 14m-19cm-5.0kN Pole | set | 42 | ¥ - | ¥ - | |
| A | A0304 | EL | 77 | Guy Wire | set | 21 | ¥ - | ¥ - | |
| EM | REPLACE MANHOLE (Sketch No. E-12) | ||||||||
| A | A0305 | EM | 78 | 600 mm (D) x 600 mm (W) x 600 mm (H) | set | 32 | ¥ - | ¥ - | |
| A | A0306 | EM | 79 | 900 mm (D) x 900 mm (W) x 1200 mm (H) | set | 21 | ¥ - | ¥ - | |
| A | A0307 | EM | 80 | 1500 mm (D) x 1500 mm (W) x 1200 mm (H) | set | 11 | ¥ - | ¥ - | |
| EN | EXCAVATION WORK (Sketch No. E-13) | ||||||||
| A | A0308 | EN | 81 | Unpaved Area | m2 | 5,250 | ¥ - | ¥ - | |
| A | A0309 | EN | 82 | Asphalt Pavement Area | m2 | 3,780 | ¥ - | ¥ - | |
| A | A0310 | EN | 83 | Concrete Pavement Area | m2 | 630 | ¥ - | ¥ - | |
| EP | REPLACE STREET LIGHT (Sketch No. E-14) | ||||||||
| Double Head Type (8m Height) | |||||||||
| A | A0311 | EP | 84 | High Pressure Sodium Lamp 110W | set | 1 | ¥ - | ¥ - | |
| A | A0312 | EP | 85 | High Pressure Sodium Lamp 180W | set | 1 | ¥ - | ¥ - | |
| Single Head Type (8m Height) | |||||||||
| A | A0313 | EP | 86 | High Pressure Sodium Lamp 110W | set | 1 | ¥ - | ¥ - | |
| A | A0314 | EP | 87 | High Pressure Sodium Lamp 180W | set | 1 | ¥ - | ¥ - | |
| A | A0315 | EP | 88 | Single Head Type (4m Height), High Pressure Sodium Lamp 70W | set | 1 | ¥ - | ¥ - | |
| Repaint Work | |||||||||
| A | A0316 | EP | 89 | 8m Height Pole | ea | 105 | ¥ - | ¥ - | |
| A | A0317 | EP | 90 | 4m Height Pole | ea | 42 | ¥ - | ¥ - | |
| EQ | REPLACE POLE MOUNTED STREET LIGHT (Sketch No. E-15) | ||||||||
| A | A0318 | EQ | 91 | High Pressure Sodium Lamp 110W | set | 3 | ¥ - | ¥ - | |
| A | A0319 | EQ | 92 | Fluorescent Light 20W | set | 3 | ¥ - | ¥ - | |
| A | A0320 | EQ | 93 | Photo-cell Switch (3A) | ea | 63 | ¥ - | ¥ - | |
| ER | REPLACE LED POLE LIGHT (Sketch No. E-16) | ||||||||
| A | A0321 | ER | 94 | 110W | set | 42 | ¥ - | ¥ - | |
| ES | REPLACE LIGHTING CONTROL PANEL (Sketch No. E-17) | ||||||||
| A | A0322 | ES | 95 | Lighting Control Panel | set | 63 | ¥ - | ¥ - | |
| A | A0323 | ES | 96 | MCCB (3P100AF), Photo-cell Switch & Wiring | set | 21 | ¥ - | ¥ - | |
| A | A0324 | ES | 97 | MCCB (3P50AF), Photo-cell Switch & Wiring | set | 42 | ¥ - | ¥ - | |
| ET | REPLACE EXIT LIGHT (Sketch No. E-18) | ||||||||
| A | A0325 | ET | 98 | LED Exit Light | set | 210 | ¥ - | ¥ - | |
| A | A0326 | ET | 99 | LED Exit Light with Mesh Guard | set | 42 | ¥ - | ¥ - | |
| EU | REPLACE EMERGENCY LIGHT (Sketch No. E-19) | ||||||||
| A | A0327 | EU | 100 | Emergency Light | set | 105 | ¥ - | ¥ - | |
| A | A0328 | EU | 101 | 10m Long Wiring System | job | 84 | ¥ - | ¥ - | |
| A | A0329 | EU | 102 | Step-up Transformer | ea | 21 | ¥ - | ¥ - | |
| A | A0330 | EU | 103 | Step-down Transformer | ea | 11 | ¥ - | ¥ - | |
| EV | REPLACE WALL LIGHTING SWITCH (Sketch No. E-20) | ||||||||
| A | A0331 | EV | 104 | Lighting Switch with a Built-in Motion Sensor | set | 63 | ¥ - | ¥ - | |
| EW | REPLACE STREET LIGHT WITH LED STREET LIGHT (Sketch No. E-21A) | ||||||||
| Single Head Type (8m Height) | |||||||||
| A | A0332 | EW | 105 | LED, 5W x 18 | set | 84 | ¥ - | ¥ - | |
| F | PIPE | ||||||||
| 5 | DOUBLE WALL PIPE FOR STEAM | ||||||||
| A | A0333 | F | BP | 150mm x 50mm thickness x 80 mm | M | 171 | ¥ - | ¥ - | |
| A | A0334 | F | CF | 50mm x 30mm thickness x 40 mm | M | 24 | ¥ - | ¥ - | |
| 6 | STEEL PIPE, BLACK, JIS G-3052 or Equivalent | ||||||||
| A | A0335 | F | CL | PIPE, 40A - 50A | M | 45 | ¥ - | ¥ - | |
| A | A0336 | F | CM | PIPE, 65A - 80A | M | 15 | ¥ - | ¥ - | |
| A | A0337 | F | CP | PIPE, 150A - 200A | M | 30 | ¥ - | ¥ - | |
| G | PIPE FITTINGS AND APPURTENANCES | ||||||||
| 2 | FLANGE JIS 10K or Equivalent | ||||||||
| A | A0338 | GB | DM | 40A - 50A | EA | 60 | ¥ - | ¥ - | |
| A | A0339 | GB | DN | 65A - 80A | EA | 30 | ¥ - | ¥ - | |
| A | A0340 | GB | DQ | 150A - 200A | EA | 30 | ¥ - | ¥ - | |
| 4 | GATE VALVE JIS 10K or Equivalent | ||||||||
| A | A0341 | GD | EA | 25A - 32A | EA | 12 | ¥ - | ¥ - | |
| A | A0342 | GD | EB | 40A - 50A | EA | 24 | ¥ - | ¥ - | |
| 6 | VALVE GLOBE JIS 10K or Equivalent | ||||||||
| A | A0343 | GF | ER | 40A - 50A | EA | 6 | ¥ - | ¥ - | |
| 7 | VALVE, CHECK SWING JIS 10K or Equivalent | ||||||||
| A | A0344 | GG | EY | 40A - 50A | EA | 15 | ¥ - | ¥ - | |
| 11 | STRAINER, Y-TYPE, #80 MESH, JIS 10K or Equivalent | ||||||||
| A | A0345 | GL | FP | 40A - 50A | EA | 5 | ¥ - | ¥ - | |
| 13 | STEAM TRAP, HEAVY DUTY TYPE JIS 10K or Equivalent | ||||||||
| A | A0346 | GN | FY | 40A - 50A | EA | 5 | ¥ - | ¥ - | |
| H | PIPE INSULATION AND COVER | ||||||||
| 1 | PIPE INSULATION | ||||||||
| A | A0347 | HA | GC | 40A - 50A | M | 45 | ¥ - | ¥ - | |
| A | A0348 | HA | GD | 65A - 80A | M | 15 | ¥ - | ¥ - | |
| A | A0349 | HA | GF | 150A - 200A | M | 30 | ¥ - | ¥ - | |
| 3 | FLANGE COVER | ||||||||
| A | A0350 | HC | GR | 40A - 50A | EA | 12 | ¥ - | ¥ - | |
| A | A0351 | HC | GS | 65A - 80A | EA | 12 | ¥ - | ¥ - | |
| A | A0352 | HC | GU | 150A - 200A | EA | 12 | ¥ - | ¥ - | |
| J | OTHER | ||||||||
| 5 | PAVING (ASSOCIATED WITH UTILITY WORK) | ||||||||
| A | A0353 | J | HM | Removal of Existing Unreinforced Concrete | CM | 1 | ¥ - | ¥ - | |
| A | A0354 | J | HP | Excavation and Backfill for Pavement | CM | 630 | ¥ - | ¥ - | |
| A | A0355 | J | HS | Aggregate Base Course, M-40, for Pavement | CM | 1 | ¥ - | ¥ - | |
| A | A0356 | J | HT | Aggregate Sub base Course, C-40 for Pavement | CM | 1 | ¥ - | ¥ - | |
| A | A0357 | J | HV | Miscellaneous Concrete | CM | 2 | ¥ - | ¥ - | |
| A | A0358 | J | HW | Solid Sodding | SM | 345 | ¥ - | ¥ - | |
| A | A0359 | J | JC | Pipe anchor, concrete base | EA | 12 | ¥ - | ¥ - | |
| A | A0360 | J | JD | Pipe sleeve seal | EA | 6 | ¥ - | ¥ - | |
| A | A0361 | J | JE | Pipe marker stick | EA | 30 | ¥ - | ¥ - | |
| 7 | ADDITIONAL ITEMS | ||||||||
| A | A0362 | J | JJ | Sand for pipe bedding | M3 | 36 | ¥ - | ¥ - | |
| A | A0363 | JG | JK | Safety fence 1.8x1.8M (Type-B) | M | 360 | ¥ - | ¥ - | |
| K | FENCING AND PAVING | ||||||||
| KA | REMOVAL AND EARTH WORK | ||||||||
| A | A0364 | KA | 1 | Remove Existing Asphalt Concrete Paved Surface | M3 | 2,940 | ¥ - | ¥ - | |
| A | A0365 | KA | 2 | Remove Existing Plain Concrete Structures | M3 | 1,470 | ¥ - | ¥ - | |
| A | A0366 | KA | 3 | Remove Existing Reinforced Concrete Structures | M3 | 1,470 | ¥ - | ¥ - | |
| A | A0367 | KA | 4 | Excavate and Dispose of Excess Materials | M3 | 3,675 | ¥ - | ¥ - | |
| A | A0368 | KA | 5 | Excavate and Backfill | M3 | 1,838 | ¥ - | ¥ - | |
| A | A0369 | KA | 6 | Fill Borrow Materials | M3 | 1,838 | ¥ - | ¥ - | |
| A | A0370 | KA | 7 | Remove 50mm Thick Cold Milling of Existing Asphalt Concrete (AC) Paved Surfaces | M2 | 14,700 | ¥ - | ¥ - | |
| A | A0371 | KA | 8 | Remove Tree with Stump and Tree Support | EA | 118 | ¥ - | ¥ - | |
| A | A0372 | KA | 9 | Remove Shrub with Tree Support | EA | 368 | ¥ - | ¥ - | |
| A | A0373 | KA | 10 | Trim Tree Branches | SET | 147 | ¥ - | ¥ - | |
| A | A0374 | KA | 11 | Perform Common Labor Work | DAY | 221 | ¥ - | ¥ - | |
| KB | PAVEMENT WORK | ||||||||
| A | A0375 | KB | 1 | Construct 50mm Thick AC Overlay of Paved Surfaces | M2 | 2,205 | ¥ - | ¥ - | |
| A | A0376 | KB | 2 | Construct 50mm Thick AC Surface Course, Binder Course and Base Course of Bituminous Stabilization (Hot-Mixed) | M2 | 29,400 | ¥ - | ¥ - | |
| A | A0377 | KB | 3 | Construct 50mm Thick Semi-Flexible Pavement Surface Course | M2 | 3,675 | ¥ - | ¥ - | |
| A | A0378 | KB | 4 | Construct 50mm Thick Porous Asphalt Concrete Surface Course | M2 | 735 | ¥ - | ¥ - | |
| A | A0379 | KB | 5 | Construct 100mm Thick Water Permeable Asphalt Concrete Pavement of Two Layer | M2 | 735 | ¥ - | ¥ - | |
| A | A0380 | KB | 6 | Construct 200mm Thick Concrete Pavement | M2 | 1,470 | ¥ - | ¥ - | |
| A | A0381 | KB | 7 | Construct 100mm Thick Water Permeable Concrete Surface Course | M2 | 735 | ¥ - | ¥ - | |
| A | A0382 | KB | 8 | Construct Plain Concrete Structures | M3 | 441 | ¥ - | ¥ - | |
| A | A0383 | KB | 9 | Construct Reinforced Concrete Structures | M3 | 294 | ¥ - | ¥ - | |
| A | A0384 | KB | 10 | Install Aggregate Base Course, M-40 | M3 | 1,911 | ¥ - | ¥ - | |
| A | A0385 | KB | 11 | Install Aggregate Subbase Course, C-40 | M3 | 1,911 | ¥ - | ¥ - | |
| A | A0386 | KB | 12 | Install Aggregate Subbase Course, RC-40 | M3 | 368 | ¥ - | ¥ - | |
| A | A0387 | KB | 13 | Construct Base and/or Subbase Course with Cement Stabilization, Not More Than 60cm in Depth | M2 | 441 | ¥ - | ¥ - | |
| A | A0388 | KB | 14 | Install and Repair Cracks with Membrane on AC or Concrete Pavement | M2 | 588 | ¥ - | ¥ - | |
| A | A0389 | KB | 15 | Route and Seal Cracks on Existing AC or Concrete Pavement | M | 1,176 | ¥ - | ¥ - | |
| A | A0390 | KB | 16 | Install Solid Sodding | M2 | 1,470 | ¥ - | ¥ - | |
| A | A0391 | KB | 17 | Apply Pavement Marking (Reflective Paint) | M | 6,909 | ¥ - | ¥ - | |
| A | A0392 | KB | 18 | Remove Existing Traffic Paint | M | 2,352 | ¥ - | ¥ - | |
| A | A0393 | KB | 19 | Apply Heliport Marking (Reflective Paint) | M2 | 1,838 | ¥ - | ¥ - | |
| A | A0394 | KB | 20 | Remove existing playground poured impact absorbing rubber surfacing (40-80mm) | M2 | 210 | ¥ - | ¥ - | |
| A | A0395 | KB | 21 | Construct playground poured impact absorbing rubber surfacing (top coat rubber 15mm and base course rubber 25mm.) with preform field impact test ASTM F1292. PLAYTOP or approved equal. | M2 | 105 | ¥ - | ¥ - | |
| A | A0396 | KB | 22 | Construct playground poured impact absorbing rubber surfacing (top coat rubber 15mm and base course rubber 25mm.) with preform field impact test ASTM F1292. PLAYTOP or approved equal | M2 | 105 | ¥ - | ¥ - | |
| KC | DRAINAGE WORK | ||||||||
| A | A0397 | KC | 1 | Install Gutter Inlet | EA | 74 | ¥ - | ¥ - | |
| A | A0398 | KC | 2 | Install 240mm or 300mm Precast Concrete U-type Ditch | M | 441 | ¥ - | ¥ - | |
| A | A0399 | KC | 3 | Install Steel Grating (T-25) for U-type Ditch | KG | 4,410 | ¥ - | ¥ - | |
| A | A0400 | KC | 4 | Install Catch Basin | EA | 74 | ¥ - | ¥ - | |
| A | A0401 | KC | 5 | Install Precast Concrete Manhole | EA | 45 | ¥ - | ¥ - | |
| A | A0402 | KC | 6 | Install 200mm to 300mm Diameter PVC Drain Pipe | M | 353 | ¥ - | ¥ - | |
| A | A0403 | KC | 7 | Install 300mm to 450mm Diameter Concrete Drain Pipe | M | 236 | ¥ - | ¥ - | |
| A | A0404 | KC | 8 | Raise / Lower Existing Manhole Frame and Cover | EA | 118 | ¥ - | ¥ - | |
| A | A0405 | KC | 9 | Raise / Lower Existing Handhole or Catch Basin Frame and Cover | EA | 118 | ¥ - | ¥ - | |
| A | A0406 | KC | 10 | Raise / Lower Existing Gate Valve Cover and Box | EA | 74 | ¥ - | ¥ - | |
| A | A0407 | KC | 11 | Replace Existing Manhole or Catch Basin Frame and Cover | EA | 45 | ¥ - | ¥ - | |
| KD | TRAFFIC CONTROL WORK | ||||||||
| A | A0408 | KD | 1 | Install Traffic Sign | EA | 59 | ¥ - | ¥ - | |
| A | A0409 | KD | 2 | Install Traffic Plate | EA | 177 | ¥ - | ¥ - | |
| A | A0410 | KD | 3 | Install Guard Rail (Type-B) | M | 177 | ¥ - | ¥ - | |
| A | A0411 | KD | 4 | Install Guard Rail (Type-SS) | M | 89 | ¥ - | ¥ - | |
| KE | FENCE WORK | ||||||||
| A | A0412 | KE | 1 | Remove Existing Chain Link Fence and Gate including Concrete Footing, Posts and other Accessories | m | 882 | ¥ - | ¥ - | |
| A | A0413 | KE | 2 | Remove Existing Chain Link Fence and Gate including Concrete Wall Foundation, Posts and other Accessories | m | 309 | ¥ - | ¥ - | |
| A | A0414 | KE | 3 | Remove Existing Chain Link Fence and Gate including Concrete Block, Concrete Wall Foundation and other Accessories | m | 309 | ¥ - | ¥ - | |
| A | A0415 | KE | 4 | Remove Existing Double Gate including Concrete Foundation and Other Accessories | m | 133 | ¥ - | ¥ - | |
| A | A0416 | KE | 5 | Install Security Chain Link Fence | m2 | 882 | ¥ - | ¥ - | |
| A | A0417 | KE | 6 | Install Security Top Guard on Existing Fence Post | ea | 147 | ¥ - | ¥ - | |
| A | A0418 | KE | 7 | Install Security Gate, 1.5m to 9.0m in Wide | m | 45 | ¥ - | ¥ - | |
| A | A0419 | KE | 8 | Install Prefabricated Fence | m2 | 206 | ¥ - | ¥ - | |
| A | A0420 | KE | 9 | Install Prefabricated Gate, 1.2m to 3.0m in Wide | m | 45 | ¥ - | ¥ - | |
| A | A0421 | KE | 10 | Install Grounding System | ea | 45 | ¥ - | ¥ - | |
| A | A0422 | KE | 11 | Construct Plain Concrete Foundation for Fence and Gate | m3 | 45 | ¥ - | ¥ - | |
| A | A0423 | KE | 12 | Construct Concrete Block for Fence | m2 | 45 | ¥ - | ¥ - |
This is the start of the file's text. The full file is on GovTribe.