St_Stephen_Crane_Control_-_Amemdment__1.docx
DOCX document 13 KB Posted
- Solicitation number
- W912HP-13-R-0013
About this file
St Stephen Crane Control Amendment
View the file
Other files
| File | Type | Posted |
|---|---|---|
| St_Stephen_Crane_Control_Site_Visit_Questions.docx | DOCX document | |
| St__Stephen_Bridge_Crane_Rehab_-_Specifications.docx | DOCX document | |
| St_Stephen_Bridge_Crane_Rehab_-_Scope_of_Work_Final_V_1_(2).docx | DOCX document | |
| 13r0013_site_visit_roster_2013.03.06.pdf | ||
| Full_Package_RTA_Crane_Rehab2_19_13.pdf | ||
| Bridge_Crane_7C.GIF | GIF image | |
| Appendix_C.docx | DOCX document | |
| Bridge_Crane_7B.GIF | GIF image | |
| Bridge_Crane_7A.GIF | GIF image | |
| Appendix_K.docx | DOCX document | |
| Appendix_A.docx | DOCX document | |
| Appendix_D.docx | DOCX document | |
| Bridge_Crane_9F.GIF | GIF image | |
| Bridge_Crane_1A.GIF | GIF image | |
| Bridge_Crane_7D.GIF | GIF image | |
| Appendix_B.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
St Stephen Crane Control Amendment #1
Scope of Work Paragraph 2.5 -Added requirement for replacement of the trolley brakes
Paragraph 2.6 -Added requirement for replacement of the bridge brake
Specification 41 01 20.73 26 Paragraph 1.1 -Added requirement for replacement of the trolley brakes and bridge brake.
Paragraph 1.5.7 -Added the word “new” to the paragraph to further clarify that electrical installation drawings are required only for new equipment.
Paragraph 2.1.2.2 -Changed the minimum conductor bar ampacity from 400A to 225A.
Paragraph 2.3.1 -Indentified the total number of “Emergency Stop” devices (5 totals) in the powerhouse.
-Added requirements for two additional pushbuttons on the operator control station 2.3.1(l) and 2.3.1(m).
Paragraph 2.4.2(b) -Identified 5 alarms/indicating lights to be provided at the operator control station.
Paragraph 2.5.3.6 -Removed requirement to have provision for incoming AC power leads.
Paragraph 2.9 -Added paragraph 2.9 for Holding Brakes for bridge and trolley brakes.