This document is a set of drawings and schedules related to a federal contract opportunity for the repair of the Camp Merrill Building 11 Post Exchange (PX) facility. The solicitation number is W912HN24B4007 and the project number is RA-52311-3P. The U.S. Army Corps of Engineers (USACE) Savannah District is managing this project, which requires repairs to the fire suppression, fire alarm, HVAC, interior finishes, ceiling, lighting, communications, and power systems. The drawings provide details on the mechanical and electrical systems, including equipment schedules, duct and piping layouts, and electrical panel schedules. The project is ready to advertise, and full design has been provided by an architect-engineer. No other details about the solicitation, pricing, or contract terms are included in these documents.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STOCK ROOM
MECHANICAL
OFFICE
COMM
SHOP FLOOR
101RESTROOM
JAN
DCU-2
DCU-1
DCU-3 DCU-4
DSS-5
DSS-6
DCU-6
DCU-5
6" øO
A
OA6"ø
8"øOA
OA8"ø
DSS-2
DSS-1 DSS-3
EF-1
EF-2
1 2 3 4
A
B
SF-1
SF-2
SF-3
DSS-4T
T
T
T
T
T
SF-4
SD-1, 6" DIA
50 CFM
SF-5 4"ø
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
Au to de sk
D oc s:
//C am p
M er ril l R ep ai r P X
BL
D
G
1/
-0
3- C am p
M er ril l B
P
X_ M
.rv t 9/
/2
:0
6:
A M
M-101
M
EC
H
AN
IC
AL
F
IR
ST
F
LO
O
R P
LA
N
C
AM
P M
ER
R
IL
L, G
EO
R G
IA
SA
VA
N
N
AH
D
IS
TR
IC
T
SA
VA
N
N
AH
, G A
M . B
U
SB
Y
E.
V
EN
C
IL
L
C . G
AJ
ER
A
F.
G
O M
EZ
AU
G
U
ST
W
2H N
-2 4-
B-
R
EA
D Y
TO
A
D
VE
R
TI
SE
(R
TA
R
EP
AI
R
E
XT
/IN
T, M
EP
, P X
FA
C
IL
IT
Y, B
PN
: R
A-
1-
3- P
1/8" = 1'-0"C4 MECHANICAL FIRST FLOOR PLAN
PLAN NORTH
0 4' 8' 16'
SHEET KEYNOTES
1.
2.
EXISTING WATER HEATER.
COORDINATE INSTALLATION OF UNIT BETWEEN ROOF
TRUSSES AND WITHIN CEILING GRID.
3. EXISTING ELECTRIC UNIT HEATER.
4. EXTERIOR WALL CAP
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
9/
/2
1 1
DUCTLESS SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE
PLAN MARK SERVES
INDOOR UNIT DATA OUTDOOR DATA
REMARKSMINIMUM
SENSIBLE
COOLING
CAPACITY
(MBH)
MINIMUM
TOTAL
COOLING
CAPACITY
(MBH)
ROOM AIR
CONDITION VOLT/PH/HZ PLAN MARK
AMBIENT AIR
TEMPERATURE
(DEG F)
VOLT/PH/HZ
COOLING
DB, DEG F
DSS-1 STOCK ROOM 8.4 12.3 78 208/1/60 DCU-1 100 208/1/60 1,2,3,4,5,6,7,8,9,10
DSS-2 STOCK ROOM 8.4 12.3 78 208/1/60 DCU-2 100 208/1/60 1,2,3,4,5,6,7,8,9,10
DSS-3 SHOP FLOOR 10.6 15.8 78 208/1/60 DCU-3 100 208/1/60 1,2,3,4,5,6,7,8,9,10
DSS-4 SHOP FLOOR 10.6 15.8 78 208/1/60 DCU-4 100 208/1/60 1,2,3,4,5,6,7,8,9,10
DSS-5 OFFICE 3.1 4.6 78 208/1/60 DCU-5 100 208/1/60 1,2,4,5,6,7,8,9,10, 11
DSS-6 COMM 12 12 72 208/1/60 DCU-6 100 208/1/60 1,2,4,5,6,7,8,9,10,11
REMARKS
1. VARIABLE SPEED INVERTER.
2. LOW AMBIENT KIT.
8. PROVIDE CONDENSATE PUMP WITH LEVEL SHUT OFF W/ ALARM.
3. CEILING MOUNT INDOOR UNIT, SIZED TO FIT BETWEEN JOISTS.
9. PROVIDE WIRED REMOTE THERMOSTAT.
4. LOW VOLTAGE CONTROLS.
10. PROVIDE REFRIGERANT LINE SETS PER MANUFACTURER RECOMMENDATIONS
PER REFRIGERANT PIPE LAYOUT.
5. PROVIDE WITH DISCONNECT SWITCH.
6. PROVIDE HAIL GUARD FOR OUTDOOR UNIT.
11. WALL MOUNT INDOOR UNIT
7. SINGLE POINT ELECTRICAL CONNECTION.
OA
N/A N/A
(CFM)
TOTAL
HEATING
CAPACITY
@5F (MBH)
ROOM AIR
CONDITION
HEATING
DB, DEG F
13.5 68 13.5 16.3 16.3 4.8
MINIMUM
SUPPLY
AIR
(CFM)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Fi le
P at h:
Pl ot D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
Au to de sk
D oc s:
//C am p
M er ril l R ep ai r P X
BL
D
G
1/
-0
3- C am p
M er ril l B
P
X_ M
.rv t 9/
/2
:0
6:
A M
M-601
M
EC
H
AN
IC
AL
S C
H
ED
U
LE
S
C
AM
P M
ER
R
IL
L, G
EO
R G
IA
SA
VA
N
N
AH
D
IS
TR
IC
T
SA
VA
N
N
AH
, G A
M . B
U
SB
Y
E.
V
EN
C
IL
L
C . G
AJ
ER
A
F.
G
O M
EZ
AU
G
U
ST
W
2H N
-2 4-
B-
R
EA
D Y
TO
A
D
VE
R
TI
SE
(R
TA
R
EP
AI
R
E
XT
/IN
T, M
EP
, P X
FA
C
IL
IT
Y, B
PN
: R
A-
1-
3- P
FAN SCHEDULE
PLAN
MARK TYPE SERVICE DRIVE
FLOW
(CFM)
ESP (IN
W.G.)
ELECTRICAL MAX
SONES REMARKS(HP) VOLT/PH/HZ
EF-1 CEILING MOUNTED 104 RESTROOM DIRECT 50 0.25 0.02 115/1/60 0.8 1, 2, 3, 5
EF-2 CEILING MOUNTED 106 JANITOR DIRECT 50 0.25 0.02 115/1/60 0.8 1, 2, 3, 5
SF-1 INLINE DSS-3 DIRECT 70 0.25 0.03 115/1/60 1.3 1, 2, 4
SF-2 INLINE DSS-4 DIRECT 70 0.25 0.03 115/1/60 1.3 1, 2, 4
SF-3 INLINE DSS-1 DIRECT 50 0.25 0.02 115/1/60 0.4 1, 2, 4
SF-4 INLINE DSS-2 DIRECT 50 0.25 0.02 115/1/60 0.4 1, 2, 4
SF-5 CEILING MOUNTED 103 COMM DIRECT 50 0.25 0.02 115/1/60 0.8 1, 6, 7
REMARKS
1. PROVIDE ELECTRICAL DISCONNECT SWITCH.
2. PROVIDE WALL CAP.
3. INTERLOCK WITH LIGHT SWITCH.
4. INTERLOCK WITH RESPECTIVE DUCTLESS MINI-SPLIT.
5. PROVIDE BACK DRAFT DAMPER.
6. RUNS CONTINUOUSLY.
7. PRESSURIZATION COMM ROOM.
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
9/
/2
ASHRAE 62.1 OUTSIDE AIR VENTILATION SCHEDULE
ROOM NAME ROOM AREA # PEOPLE SPACE TYPE CFM/SQFTSYSTEM CFM/PERSON MIN OA ACTUAL OA CFM
105 STOCK ROOM 0 STORAGE 0.12DSS-1 & 2 0 80 100
104 RESTROOM 104 0 RESTROOM N/A N/A N/A N/A
106 JANITOR 47 0 SERVICE N/A
DSS-3 & 4
N/A N/A N/A
101 SHOP FLOOR 1581 2 SALES FLOOR 0.12 7.5 130 140
102 OFFICE 128 1 OFFICE 0.06DSS-5 5 14 0
103 COMM ROOM 82 0 ELEC EQUIP 0.06DSS-6 0 5 0
2768 3TOTAL 229 240
REMARKS
1. TABLE SHOWS WORST CASE SCENARIO, WHICH IS WHEN THE SYSTEM IS IN HEATING MODE.
2. RESTROOMS AND JANITOR'S CLOSETS ARE GOVERNED BY IMC EXHAUST RATES.
DIFFUSER SCHEDULE
TYPE INLET SIZE REMARKSMARK
12X12 EGGCRATE 1, 2SD-1 SEE PLANS
REMARKS
1. PROVIDE FRAME TO MATCH CEILING TYPE.
2. COLOR TO BE SELECTED BY ARCHITECTS.
D
D D D D
C
C
DDD D
D
DD
D
DD
D D
J
JD
D
J
D
PP1
(TYP)
3 4
DSS-3
DCU-3 DCU-4 DCU-6
DCU-5
DSS-1
DSS-2
DCU-2
DCU-1
DSS-6
DSS-5
PP1
24 24
57 432 1
10 12 14 16
6,8
PP1
PP1- 13
PP1
18 20
PP1- 13
ATSMETER
TE-1 (NEC)
TE-2
7 7
MAIN DISC.
SF-1
SF-3
SF-2
EF-2
EF-1
DSS-4
SF-4
PP1- 32
15 15
15 15
SF-5
OFFICE
COMM
SHOP FLOOR
STOCK ROOM
RESTROOM
JAN
MECHANICAL
X1
X1
W1
W1
W1W1
W1
X1
W1
A2 A2 A2
PP1- 19
A1 A1E
PP1- 25 PP1- 25 PP1- 25
21 21
191919
19 19
A1 A1 A1 A1E
A1A1E
A1 A1 A1E
A1E
A1E A1
A1 A1E
A1
A1EA1
A1E
A1E
A1
A1 A1E
A1E A1
A1 A1E
A1 A1 A1E A1 A1 A1E A1 A1
A1E
A1A1
A1
A1E
A1
A1
A1E
A1
A1
A1E
A1
A1
A1
A1
A1E
W1
X1
X1
C1
C1
W1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A u to d e s k D o c s /C a m p M e rr ill R e p a ir
P X
B L D
G
/1
-0
-C a m p M e rr ill B
P
X E
.r v t
/1
/2
:5
:0
A
M
E-101
E L E
C T
R
IC
A L P
O W
E R
A N
D L
IG
H
T
IN
G P
L A
N
C A
M P
M E
R R
IL
L G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T S
A V
A N
N A
H G
A
J O
A K
E S
J O
A K
E S
C G
A J E
R A
S M
A N
N
IN
G
A U
G U
S T
W H
N -2
-B
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
R E
P A
IR
E
X T
/I N
T M
E P
P
X F
A C
IL
IT
Y B
P N
R
A -5
-3
-P
1/8" = 1'-0"H1
ELECTRICAL POWER & TELECOM PLAN
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1 /2
1/8" = 1'-0"A1
ELECTRICAL LIGHTING PLAN
GENERAL NOTES
1. REFER TO SHEET E-001 FOR ELECTRICAL / TELECOM
SYMBOLS AND ABBREVIATIONS.
2. ALL LUMINAIRES ARE TYPE A1 UNLESS OTHERWISE
NOTED.
3. AAFES WILL INSTALL ALL SECURITY AND IT WIRING
WITHIN THE RETAIL SPACE, MPA AND OFFICE AREAS.
CONTRACTOR TO PROVIDE PATHWAYS AND BOXES WITH
PULL STRINGS ONLY.
KEYNOTES
1. "D" ANNOTATION DESIGNATES DEDICATED 120V, 20A
RECEPTACLE.
2. PROVIDE 120V, 20A, CONNECTION FOR SIGNAGE.
COORDINATE LOCATION WITH SIGN VENDOR. ROUTE
THRU ASTRONOMICAL ELECTRONIC TIME CLOCK.
3. PROVIDE 6"W x 4"D WIRE MESH CABLE TRAY FOR
NIPRNET CABLING. MOUNT CABLE TRAY ABOVE
ACCESSIBLE CEILING . COORDINATE ROUTING OF TRAY
WITH LIGHTING, MECHANICAL, FIRE PROTECTION, AND
PLUMBING PRIOR TO STARTING INSTALLATION.
4. PROVIDE (2) 3 INCH CONDUITS FROM CABLE TRAY TO
TTB. STUB DOWN AND TERMINATE 6 INCHES BELOW
PLYWOOD BACKBOARD.
5. PROVIDE RECEPTACLES IN CEILING ABOVE WINDOW.
6. PROVIDE JUNCTION BOX FOR CONNECTION TO ABA
PUSHBUTTON POWER SUPPLY.
7. PROVIDE 2-CHANNEL POWER POLE FOR TELECOM AND
POWER TO CASH REGISTERS.
8. EXISTING MECHANICAL EQUIPMENT. REFER TO
MECHANICAL FOR MORE INFORMATION.
0 4' 8' 16'
0 4' 8' 16'
PLAN NORTH
PLAN NORTH
09/11/2024
SPD
20S
1-PH
ATS
200A
"PP1"
PANEL
200A
M
PROVIDE AMILCALOLA EMC
APPROVED SINGLE PHASE
120/240V, 200A SELF
CONTAINED METER
20' SPACING MIN.
GRADE
35KW,1-PH,120/240V
DIESEL GENSET W/ 48hr
UL 142 BASE TANK &
WP ENCL.W REMOTE PNL
PROVIDE WEATHER HEAD
AND 200A SERVICE DROP
IN 2" RGC
#2/0 Cu
TYP
CONNNECT TO
EXISTING LIGHTNING
PROTECTION
EXISTING POLE MOUNTED
TRANSFORMER 37.5KVA TO
REMAIN
AMICALOLA EMC TO RE-
ATTACH SECONDARIES TO
NEW SERVICE DROP
LOCATION. COORDINATE WITH
THEIR POC.
LOCATED
INTERIOR TO
BLDG.
MAIN
DISCONNECT
20Y
20Y 20Y
20Y
FEEDER SCHEDULE
FEEDER
MARK
10Y 10N
11Y 11N
12Y 12N
15Y 15N
17Y 17N
20S 20Y 20N
22Y 22N
25Y 25N
AMPACITY
NO. OF SETS
CONDUCTOR SIZES (AWG or kcmil)
PHASE NEUTRAL EQ GRND
CONDUIT SIZE
1-1/2" 1-1/2"
2"
1-1/2" 2" 2"
1-1/2" 2"
2-1/2"
1-1/2" 2"
2-1/2"
2" 2"
2-1/2"
2" 2-1/2"
3"
2" 2-1/2"
3"
2-1/2" 3"
3-1/2"
2 - #1 2 - #1 2 - #1
1 - #1
1 - #3/0
1 - #8 1 - #8 1 - #8
2 - #1 2 - #1 2 - #1
1 - #1
1 - #4/0
1 - #6 1 - #6 1 - #6
2 - #1/0 2 - #1/0 2 - #1/0
1 - #1/0 1 - #250
1 - #6 1 - #6 1 - #6
2 - #1/0 2 - #1/0 2 - #2/0
1 - #1/0 1 - #350
1 - #6 1 - #6 1 - #4
2 - #2/0 2 - #2/0 2 - #3/0
1 - #2/0 2 - #2/0
1 - #6 1 - #6 1 - #4
2 - #3/0 2 - #3/0 2 - #4/0
1 - #3/0 1 - #3/0 2 - #3/0
1 - #6 1 - #4
2 - #4/0 2 - #4/0 2 - #250
1 - #4/0 2 - #4/0
1 - #4 1 - #4 1 - #3
2 - #250 2 - #250 2 - #300
1 - #250 2 - #250
1 - #4 1 - #4 1 - #3
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
A u to d e s k D o c s /C a m p M e rr ill R e p a ir
P X
B L D
G
/1
-0
-C a m p M e rr ill B
P
X E
.r v t
/1
/2
:5
:0
A
M
E-601
E L E
C T
R
IC
A L O
N E
L
IN
E
S C
H E
D U
L E
S
C A
M P
M E
R R
IL
L G
E O
R G
IA
S
A V
A N
N A
H D
IS
T
R
IC
T S
A V
A N
N A
H G
A
J O
A K
E S
J O
A K
E S
C G
A J E
R A
S M
A N
N
IN
G
A U
G U
S T
W H
N -2
-B
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
R E
P A
IR
E
X T
/I N
T M
E P
P
X F
A C
IL
IT
Y B
P N
R
A -5
-3
-P
N.T.S.E9
ELECTRICAL POWER ONE-LINE
1. REFER TO SHEET E-001 FOR ELECTRICAL SYMBOLS AND
ABBREVIATIONS.
2. NOT ALL CONNECTIONS MAY BE SHOWN.
3. MAKE CONNECTIONS TO ALL EQUIPMENT AS
RECOMMENDED BY MANUFACTURER.
4. AIC RATING OF ALL EQUIPMENT TO BE 10KAIC MINIMUM.
5. REFER TO POWER COMPANY POINT OF CONTACT:
A. BO COX: (706) 974-7653
6. REFER TO SITE PLAN AND AREA PLAN FOR LOCATION OF
SERVICE EQUIPMENT (METER, ATS) AND SERVICE
DISCONNECT (MAIN DISCONNECT).
GENERAL SHEET NOTES
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1 /2
LUMINAIRE SCHEDULE
MARK MOUNTING TYPE MOUNTING LOCATION SHAPE SIZE LAMP LUMINOUS FLUX INITIAL COLOR TEMPERATURE FIXTURE VOLTS FIXTURE WATTS COMMENTS COUNT
A1 SURFACE INTERIOR CEILING RECTANGULAR 1X4 LED 5800 lm 4000 K 120 V 64 W LOW PROFILE SURFACE MOUNTED 1X4 LED FIXTURE WITH LENS 33
A1E SURFACE INTERIOR CEILING RECTANGULAR 1X4 LED 5800 lm 4000 K 120 V 64 W LOW PROFILE SURFACE MOUNTED 1X4 LED FIXTURE WITH LENS W/ 90-MIN EMERGENCY BATTERY BACKUP 20
A2 SURFACE UNDER EXTERIOR CANOPY RECTANGULAR 1X4 LED 5800 lm 4000 K 120 V 64 W LOW PROFILE SURFACE MOUNTED 1X4 LED FIXTURE WITH LENS AND WEATHERPROOF HOUSING 3
C1 RECESSED INTERIOR CEILING ROUND 6" LED 1100 lm 4000 K 120 V 77 W 6" RECESSED WALL WASH CAN LIGHT WITH ADJUSTABLE GIMBAL 2
W1 SURFACE WALL TRAPAZOID LED 5548 lm 4000 K 120 V 71 W DARK BRONZE WALL PACK WITH MOTION SENSOR AND INTERGRAL PHOTOCELL W/ 90-MIN EMERGENCY BATTERY BACKUP 8
X1 COMBO WALL OR CEILING RECTANGULAR 12" LED 810 lm 4000 K 120 V 5 W EXIT SIGN WITH 90 MINUTE BATTERY BACK UP 5
MECHANICAL EQUIPMENT ELECTRICAL CONNECTION SCHEDULE
ITEM DESCRIPTION VOLT PH KVA HP MCA (A) DISCONNECT STARTER C/B SIZE WIRE SIZE CONDUIT PANEL CKT # NOTES
DSS-1/DCU-1 SPLIT SYSTEM 208 V 1 1.06 N/A 6.3 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 31,33 1,2,3,4,5
DSS-2/DCU-2 SPLIT SYSTEM 208 V 1 1.06 N/A 6.3 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 31,33 1,2,3,4,5
DSS-3/DCU-3 SPLIT SYSTEM 208 V 1 1.06 N/A 6.3 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 35,37 1,2,3,4,5
DSS-4/DCU-4 SPLIT SYSTEM 208 V 1 1.06 N/A 6.3 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 35,37 1,2,3,4,5
DSS-5/DCU-5 SPLIT SYSTEM 208 V 1 1.00 N/A 6.0 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 39,41 1,2,3,4,5
DSS-6/DCU-6 SPLIT SYSTEM 208 V 1 1.00 N/A 6.0 A 30/1/NF/NEMA 1 FURN W/ EQUIP 20 A #12 + #12 G 3/4" C PP1 39,41 1,2,3,4,5
EF-1 EXHAUST FAN 120 V 1 0.04 1/8 0.4 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 19 1,2,4,5
EF-2 EXHAUST FAN 120 V 1 0.04 1/8 0.4 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 19 1,2,4,5
SF-1 SUPPLY FAN 120 V 1 0.18 1/6 1.9 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 19 1,2,4,5
SF-2 SUPPLY FAN 120 V 1 0.18 1/6 1.9 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 21 1,2,4,5
SF-3 SUPPLY FAN 120 V 1 0.02 1/8 0.2 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 19 1,2,4,5
SF-4 SUPPLY FAN 120 V 1 0.02 1/8 0.2 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 19 1,2,4,5
SF-5 SUPPLY FAN 120 V 1 0.02 1/8 0.2 A TOGGLE SWITCH N/A 20 A #12 + #12 G 3/4" C PP1 21 1,2,4,5
Receptacle 34596 VA 64.45% 22298 VA Total Est. Demand Current: 159 A
Lighting - Exterior 408 VA 100.00% 408 VA Total Conn. Current: 218 A
Equipment 6723 VA 100.00% 6723 VA Total Est. Demand: 33140 VA
Power 270 VA 100.00% 270 VA Total Conn. Load: 45431 VA
Lighting 3618 VA 100.00% 3618 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 229 A
Total Load: 24284 VA
41 -- -- -- 1000 VA / 0 VA -- -- -- 42
39 DSS/DCU 5 & 6 20 A 2 1000 VA / 0 VA 2 20 A SPD 40
37 -- -- -- 1056 VA / 0 VA 1 20 A SPARE 38
35 DSS/DCU 3 & 4 20 A 2 1056 VA / 0 VA 1 20 A SPARE 36
33 -- -- -- 1056 VA / 2400 VA 1 20 A COMM CABINETS 34
31 DSS/DCU 1 & 2 20 A 2 1056 VA / 90 VA 1 20 A FA MNS PANEL 32
29 ABA DOOR OPENER 20 A 1 180 VA / 180 VA 1 20 A OFFICE PRINTER 30
27 EXTERIOR RECEPTACLES 20 A 1 1080 VA / 180 VA 1 20 A OFFICE PRINTER 28
25 EXTERIOR LIGHTING 20 A 1 600 VA / 1440 VA 1 20 A EXT. ATM RECEPT 26
23 SHOP FLOOR LTG 20 A 1 1566 VA / 360 VA 1 20 A CASH REGISTER RECEPT 24
21 OFFICE/COMM LTG 20 A 1 584 VA / 1440 VA 1 20 A COFFEE MAKER 22
19 STOCK/MECH LTG 20 A 1 1756 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 20
17 OFFICE RECEPT 20 A 1 1080 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 18
15 COMM RECEPT 20 A 1 1080 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 16
13 MECH/STOCK RM RECEPT 20 A 1 1260 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 14
11 REACH-IN COOLER 20 A 1 1440 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 12
9 REACH-IN FREEZER 20 A 1 1440 VA / 1680 VA 1 20 A REACH-IN REFRIGERATOR 10
7 UC MICROWAVE 20 A 1 1440 VA / 1248 VA -- -- -- 8
5 UC REFRIGERATOR 20 A 1 1440 VA / 1248 VA 2 20 A REACH-IN COOLER 6
3 UC FREEZER 20 A 1 1440 VA / 1440 VA 1 20 A GRIDDLE RECEPT 4
1 GRIDDLE RECEPT 20 A 1 1440 VA / 1440 VA 1 20 A UC FREEZER 2
CKT Circuit Description Trip Poles
A B
Poles Trip Circuit Description CKT
Enclosure: Type 1 Fault Current: 24284 VA
Mounting: SURFACE Wires: 3 Mains Rating: 200 A
Supply From: UTIL XFMR Phases: 1 Mains Type: CB
Location: STOCK ROOM 105 Volts: 120/208 Single A.I.C. Rating: 10000
Panel: PP1
NOTES:
1. DISCONNECTS AND MOTOR STARTERS PROVIDED BY DIVISION 23 AND INSTALLED BY DIVISION 26.
2. TEST ALL EQUIPMENT FOR PROPER OPERATION AFTER COMPLETION OF WORK.
3. INSIDE UNIT IS FED VIA OUTSIDE UNIT INTERCONNECTION CONDUIT AND WIRING PROVIDED BY ELECTRICAL CONTRACTOR.
4. COORDINATE FINAL LOCATIONS OF EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.
5. REFER TO FEEDER SCHEDULE FOR WIRE SIZE INFORMATION.
KEYNOTES
1. SERVICE EQUIPMENT MOUNTED TO EXTERIOR WALL.
REFER TO E-101 FOR APPROXIMATE LOCATION.
09/11/2024
| M-101 MECHANICAL FIRST FLOOR PLAN |
| M-601 MECHANICAL SCHEDULES |
| E-101 ELECTRICAL POWER AND LIGHTING PLAN |
| E-601 ELECTRICAL ONE LINE & SCHEDULES |
File details come from the government source that posted it. Updated .