About this file

This is a synopsis for a solicitation notice for construction services. The U.S. Army Corps of Engineers Savannah District is seeking a firm-fixed-price contract for a $10-25 million project to construct a 20,654 square foot second floor addition to an existing administrative building at Robins Air Force Base in Warner Robins, Georgia. The work includes updating mechanical, plumbing, electrical and unified monitoring control systems for the new addition. The solicitation will be posted on January 13, 2023 and bids are due via PIEE by February 24, 2023. The contract is a 100% small business set-aside under NAICS code 236220 with a size standard of $45 million. The period of performance is 900 calendar days from notice to proceed. A site visit is scheduled for January 30, 2023. Questions are due in accordance with the forthcoming solicitation.

View the file

Other files

File Type Posted
C.04 - Bid Abstract W912HN23R4003 (signed).pdf PDF
W912HN-23-R-4003_SPECS_AMD6.pdf PDF
B.08 - Amendment 0006 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0006 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
2023.02.16 sign in sheet.pdf PDF
B.08 - Amendment 0005 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0005 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0004 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
W912HN-23-R-4003_SPECS_AMD4.pdf PDF
B.08 - Amendment 0004 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
W912HN-23-R-4003_DRAWINGS_AMD4.pdf PDF
B.08 - Amendment 0003 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0003 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
2023.01.30 Bldg 231 Contractor's Walk Sign in Sheet.pdf PDF
B.08 - Amendment 0002 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0002 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0001 (SF30) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B.08 - Amendment 0001 (Conformed Copy) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
B231 Addition_Geotechnical Report.pdf PDF
B231 Addition_Hazard_Material_Survey.pdf PDF
B.08 - Solicitation (released) - W912HN22R4003 - UHHZ113000 B231 Addition RAFB.pdf PDF
Robins AFB Access Affidavit (Revised 31 Oct 2022).pdf PDF
W912HN-23-R-4003_SPECS.pdf PDF
W912HN-23-R-4003_DRAWINGS.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

100'-0"

1.E 10.E

SECOND FLOOR

115'-5 1/2"

T.O. TRUSS @

OUSIDE FACE OF

CMU

129'-1 1/2"

A1

A-301

8.E 9.E7.E6.E5.E4.E3.E2.E

EXISTING LAB BUILDING

/2

H15

A-505

2" / 12" 2" / 12"

FIRST FLOOR

100'-0"

1.E10.E

SECOND FLOOR

115'-5 1/2"

T.O. TRUSS @

OUSIDE FACE OF

CMU

129'-1 1/2"

8.E9.E 7.E 6.E 5.E 4.E 3.E 2.E

EXISTING BUILDING 231 EXISTING LAB BUILDING

/2

/2

3 H15

A-505

22'-10"

L204L208

L210

L209

2" / 12" 2" / 12"

/8

2'-5 15/16" 13'-9 9/16" 1'-11 3/4"

/8

L211

SHEET KEYNOTES:.GENERAL SHEET NOTES:.

1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS,

SEE SHEET A-002.

2. ALIGN NEW VERTICAL REVEAL LOCATIONS WITH

EXISTING VERTICAL REVEALS

1. NOT USED

2. EXISTING BUILDING ENTRANCE CANOPY TO

REMAIN

3. PROVIDE NEW EIFS SYSTEM TO MATCH TEXTURE,

COLOR, AND REVEAL DIMENSIONS TO MATCH

EXISTING FIRST FLOOR CONDITIONS.

4. EXISTING BUILDING SIGNAGE TO REMAIN

5. NOT USED

6. GUTTER, DOWNSPOUT, AND SPLASHBLOCK. TYP

7. STANDING SEAM METAL ROOF

8. EXTERIOR DOOR, (PROVIDE COLOR

INFORMATION)

9. EXTERIOR LOUVER

10. EXISTING BERM

11. EXISTING DOOR, NO WORK

12. EXISTING ANTENNA, RELOCATED TO EXT. FACADE.

REFER TO G-111

13. RECESSED REVEALS. ALIGN WITH EXISTING

REVEALS BELOW AND MATCH EXISTING WIDTH

AND DEPTH.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

U s e rs

\W a l0

\O n e D ri v e

B la c k

V e a tc h \D o c u m e n ts

\R A

F B

-B L D

G -A

W a lk e rR

M .r v t

/2

/2

:4

:3

P

M

A-200

B U

IL

D

IN

G

E L E

V A

T

IO

N S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

S K

E T

C H

U M

B H

E G

A R

T Y

L A

D A

M S

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

1/8" = 1'-0"H1

NORTH BUILDING ELEVATION

1/8" = 1'-0"B1

SOUTH BUILDING ELEVATION

8'4' 16'0

8'4' 16'0

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

SCHEDULED CEILING

5/8" TYPE "X" GWB (LAYERS PER PARTITION NOTES)

METAL STUD @ 24" OC UNO

FINISH FLOOR

HEAD

PLAN

BASE

WALL TYPE A NOTES:

1. (1) LAYER 5/8" TYPE "X" GWB EACH SIDE

2. (2) LAYER 5/8" TYPE "X" GWB EACH SIDE

DEFLECTION TRACK W/ 1/2"

COMPRESSION OR EXTENSION.

SECURED TO BOTTOM OF ROOF TRUSS

OR STRUCTURE ABOVE

BOTTOM TRACK- SET IN CONT. BED OF

ACOUSTICAL SEALANT

FILL STUD CAVITY WITH ACOUSTICAL INSULATION

PER SCHEDULE

5/8" TYPE "X" GWB (LAYERS PER PARTITION NOTES)

HEAD

PLAN

BASE

UNDERSIDE OF

HORIZONTAL SHAFT

WALL ABOVE

DEFLECTION TRACK W/ 2" JOINT WIDTH AND 1/2"

COMPRESSION OR EXTENSION. SECURED TO

UNDERSIDE OF STRUCTURE ABOVE (HEAD WALL DETAIL

HW-D-0638) UNLESS OTHERWISE DETAILED

(1) LAYER 5/8" GWB EACH SIDE, UNO

METAL STUD @ 16" OC

FINISH FLOOR

ISOLATION JOINT

SCHEDULED CEILING

FINISH FLOOR

HEAD

PLAN

BASE

PANEL ANCHOR CLIP

ANGLE SECURED TO

FLOOR DECK

UNDERSIDE OF

STRUCTURE ABOVE

GYP BD FURRING PER SCHEDULE

CMU REINFORCED

PER STRUCTURAL

WALL TYPE M NOTES:

1. PROVIDE 7/8" HAT CHANNEL AND (1) LAYER 5/8" GWB ON ONE SIDE.

2. FIRE RATING BASED ON FULLY GROUTED UNITS

3. INTERIOR (1) LAYER 5/8" GYP BD. ON METAL FURRING

4. PARTIAL HEIGHT KNEE WALL, CAP TOP OF WALL WITH FINISHED 1"x10" NOMINAL WIDE WOOD SILL, QUARTER ROUND EDGES.

BASE AS SCHEDULED

UNDERSIDE OF

STRUCTURE ABOVE

DEFLECTION TRACK W/ 1/2"

COMPRESSION OR EXTENSION.

SECURED TO UNDERSIDE OF

STRUCTURE ABOVE

SCHEDULED CEILING

(1) LAYER 5/8" GWB EACH SIDE

UNLESS NOTED OTHERWISE

METAL STUD @ 16" OC

FINISH FLOOR

FILL STUD CAVITY WITH

ACOUSTICAL INSULATION

PER SCHEDULE

HEAD

PLAN

BASE

(SEE FLOOR PLAN)

WALL WIDTH

WALL TYPE T NOTES:

1. 2 LAYERS OF 5/8" GYP BOARD ON THE INSULATED SIDE OF THE WALL

GENERAL SHEET NOTES:.

1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS, SEE SHEET A-002.

2. ALL FIRE AND/OR SOUND RATED WALLS SHALL EXTEND FROM SLAB TO

UNDERSIDE OF HARD CEILING STRUCTURE OR TRUSS ABOVE. PROVIDE

BRACING AS NECESSARY. DO NOT EXTEND ANY WALLS FULL HEIGHT TO

UNDERSIDE OF SLOPED ROOF. PROVIDE ACOUSTIC/FIRE RATED

SEALED TRANSITIONS FROM WALLS TO HARD CEILING LOCATIONS.

WHERE ACT GRID CEILINGS ARE SHOWN NEAR STC WALLS, NO

ACOUSTIC/FIRE SEALS ARE REQUIRED.

UNDERSIDE OF

STRUCTURE ABOVE

SCHEDULED CEILING

(1) LAYER 5/8" GWB, UNO

METAL STUD @ 16" OC

FINISH FLOOR

FILL STUD CAVITY WITH

ACOUSTICAL INSULATION

PER SCHEDULE

HEAD

PLAN

BASE

6" ABOVE CEILING UNO

WALL TYPE F NOTES:

1. PARTITION NOT REQUIRED TO MEET A SPECIFIED ACOUSTICAL RATING.

2. (2) LAYERS OF 5/8" GYPSUM WALL BOARD

HEAD

PLAN

(SHAFT SIDE)

BASE

UNDERSIDE OF STRUCTURE ABOVE

SCHEDULED CEILING

CH METAL STUD @ 24" OC

FINISH FLOOR

FILL STUD CAVITY WITH ACOUSTICAL INSULATION PER

SCHEDULE

ACOUSTICAL INSULATION IN DEFLECTION TRACK, STC WALLS

ONLY

(1) LAYER 5/8" TYPE "X" GWB, AND (1) LAYER

1" GWB SHAFT LINER ON SHAFT SIDE

DEFLECTION TRACK W/ 2" JOINT WIDTH AND 1/2"

COMPRESSION OR EXTENSION. SECURED TO UNDERSIDE OF

STRUCTURE ABOVE (HEAD WALL DETAIL HW-D-0119)

WALL TYPE H NOTES:

1. FOR STC 50 RATED WALLS, USE (2) LAYERS OF 5/8" GWB.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

U s e rs

\W a l0

\O n e D ri v e

B la c k

V e a tc h \D o c u m e n ts

\R A

F B

-B L D

G -A

W a lk e rR

M .r v t

/2

/2

:4

:3

P

M

A-500

P A

R T

IT

IO

N T

Y P

E S

D

E T

A

IL

S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

S K

E T

C H

U M

B H

E G

A R

T Y

L A

D A

M S

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

WALL

TYPE

WALL

WIDTH

CMU

WIDTH

FIRE

RATING

UL

ASSEMBLY # STC SOUND TEST # NOTE

M2 8" 8" 1 HR - - - 2

M9 9 1/2" 8" 1 HR - - - 1,2,3

M10 1'-1 1/2" 12" 1 HR - - - 1,2,3

M11 8" 8" - - - - 4

WALL

TYPE

WALL

WIDTH

STUD

WIDTH STC

MANUFACTURER'S

SOUND TEST #

INSULATION

THICKNESS NOTES

A1 5 1/4" 4" - - - 1

A3 4 7/8" 3 5/8" 45 USG-150923 3 1/2" 1

A4 6 1/8" 3 5/8" 50 RAL-TL11-073 3 1/2" 2

WALL

TYPE

WALL

WIDTH

STUD

WIDTH

FIRE

RATING

UL

ASSEMBLY # NOTE

B2 7 1/4" 6" 1 HR UL U419

WALL

TYPE

WALL

WIDTH

STUD

WIDTH

INSULATION

THICKNESS NOTE

T1 1'-4 7/8" (2) 4" 3 1/2" 1

T2 1'-5 3/4" (2) 4" 3 1/2"

NTS1

WALL TYPE A - FULL HEIGHT WALLS

NTS2

WALL TYPE B- FIRE RATED WALLS

NTS5

WALL TYPE M - MASONRY FURRED WALLS

NTS6

WALL TYPE T -TOILET CHASE WALLS

WALL

TYPE

WALL

WIDTH

STUD

WIDTH

INSULATION

THICKNESS

FIRE

RATING

FIRE TEST

FULL

HEIGHT NOTE

F1 4 5/8" 4" 4" - 1

F2 5 1/4" 4" 4" - 2

F5 1 1/2" 7/8" 7/8" - 1

NTS3

WALL TYPE F - METAL STUD FURRED WALLS

WALL

TYPE

WALL

WIDTH

STUD

WIDTH

FIRE

RATING

UL ASSEMBLY

# STC

MANUFACTURER'S

SOUND TEST #

INSULATION

THICKNESS NOTE

H2 4 5/8" 4" 1 HR UL U415 - - -

H7 5 1/4" 4" - UL U415 50 RAL-OT-04-019 3 1/2" 1

NTS4

WALL TYPE H - SHAFT WALLS

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

STANDING SEAM

METAL ROOF AND

RIDGE

METAL DECK

RIGID INSULATION,

MIN R-25

GLASS MAT

GYPSUM COVER

BOARD

TRUSS TOP CHORD

RE: STRUCTURAL

1.E

T.O. TRUSS @

OUSIDE FACE OF

CMU

129'-1 1/2"

STANDING SEAM

METAL ROOF

METAL DECK

RIGID INSULATION,

MIN R-25

METAL GUTTER AND

DOWNSPOUT

PREFINISHED METAL

SOFFIT PANEL

FLASHING AND DRIP EDGE

FLASHING AND DRIP EDGE

SOFFIT TRIM & FLASHING

SEALANT

METAL STUD GIRTS,

24" OC MAX

VERTICAL SPACING

STRUCTURAL TRUSS,

RE: STRUCTURAL

NEOPRENE CLOSURE

TRUSS TOP CHORD

CONTINUOUS, BENT PLATE.

REFER TO STRUCTURAL

GLASS MAT GYPSUM

COVER BOARD

SELF-ADHERING POLYMER-

MODIFIED ASPHALT BITUMEN

MEMBRANE UNDERLAYMENT,

SEE ROOF PLAN (A-131)

J.E

STANDING SEAM

METAL ROOF AND

RIDGE

METAL DECK

RIGID INSULATION,

MIN R-25

PREFINISHED METAL

SOFFIT PANEL

FLASHING AND

DRIP EDGE

SOFFIT TRIM &

FLASHING

SEALANT

NEOPRENE DECK

CLOSURE STRIP

METAL STUD GIRTS,

24" OC MAX

VERTICAL SPACING

GLASS MAT

GYPSUM COVER

BOARD

CONTINUOUS, STEEL

ANGLE. REFER TO

STRUCTURAL

SELF-ADHERING

POLYMER-MODIFIED

ASPHALT BITUMEN

MEMBRANE

UNDERLAYMENT, SEE

ROOF PLAN (A-131)

TRUSS RE:

STRUCTURAL

J.E

12" CMU, TOP COURSE

FILLED WITH GROUT

METAL STUD GIRTS, 24" OC

MAX VERTICAL SPACING

1/4" DIA. REINFORCING, SEE

STRUCTURAL

TOP OF CMU

126' 1 1/2"

5/8" GLASS-MAT

BOARD

2" POLYSTYRENE

INSULATION

BOARD

STUCCO FINISH

OVER REINFORCING

MESH

TRUSS RE: STRUCTURAL

FLUID APPLIED

AIR BARRIER

J.E

TOP OF MASONRY

@ EXISTING

PARAPET

118'-1 1/2"

12" CMU

EXPANSION

JOINT, FLASHING,

AND SEALANT

2" POLYSTYRENE

INSULATION

BOARD

STUCCO FINISH

OVER REINFORCING

MESH

EXISTING

PARAPET

WEEPS PER EIFS

MANUFACTURER

STD DETAILS

EXISTING STUCCO

FINISH OVER CMU.

FIELD VERIFY WALL

THICKNESS AND

ADJUST NEW EIFS

INSULATION THICKNESS

ACCORDINGLY. INFORM

ARCHITECT IF

THICKNESS WILL BE

LESS THAN 2'', TYP

A L

IG

N

FLUID APPLIED

AIR BARRIER

GENERAL SHEET NOTES:.

1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS, SEE SHEET A-002.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

U s e rs

\W a l0

\O n e D ri v e

B la c k

V e a tc h \D o c u m e n ts

\R A

F B

-B L D

G -A

W a lk e rR

M .r v t

/2

/2

:4

:3

P

M

A-505

W A

L L S

E C

T

IO

N D

E T

A

IL

S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

S K

E T

C H

U M

B H

E G

A R

T Y

L A

D A

M S

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

3" = 1'-0"H1

BUILDING SECTION DETAIL - RIDGE

3" = 1'-0"B1

SECTION DETAIL @ EAVE

3" = 1'-0"B11

SECTION DETAIL @ RAKE

3" = 1'-0"H8

WALL SECTION DETAIL - T.O.M.

3" = 1'-0"H15

WALL SECTION DETAIL - B.O.M.

1'0 6"3" 1'0 6"3" 1'0 6"3"

1'0 6"3" 1'0 6"3"

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

J

AHU-01-01

J

BLR-01-01

J

DOAS-01-01

J

HWP-01-02

J

HWP-01-01

J

J

EF-01-03

J

AHU-01-02B

J

J J

J

UH-01-03 J

UH-01-01

J

EF-01-02

J

J

J

J

J

J

J

J J J

J

J J

J

J

J

J

J J J

JJ

J

SPARE -

ROOM

J

SPARE -

ROOM

J

SPARE -

ROOM

J

SPARE

(FUTURE)

- ROOM

J

SPARE

(FUTURE)

- ROOM

J

EXTERIOR

CAMERA

J

J

J.E

3.E 2.E 1.E4.E5.E6.E7.E8.E9.E

F.E

E.E

A.E

E-401

D2

ELECTRIC

COMM

BREAK/LUNCH

MECHANICAL

ROOM

PP-231-02-001

PROGRAM MGMT

PROGRAM MGMT

STAIR B

PROGRAM MGMT

HALLWAY

STAIR C

CONFERENCE

ROOM

STOR

ACCESSIBLE RR

STORAGE

EQUIPMENT

OFFICE

OFFICE

STAIR A

JANITOR

OFFICE

BREAK/LUNCH

NEW BUSINESS

MECHANICAL

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

MEETING

ENGINEERING

CHIEF

BRANCH OFFICE

DIRECTOR

MEETING

209 OFFICE

OFFICE

OFFICE

OFFICE

HALLWAY

PROGRAM MGMT

WOMEN'S RR

MEN'S RR

ELEVATOR

OFFICE

OFFICE

OFFICE

01:1,3,5

NMR

05:28

05:15

05:25 05:15

06:2

06:2

03:1

03:1

06:2

06:2

06:2

03:1

06:2

06:1

06:1

06:1

03:4

03:4 06:1

06:1

03:4

03:4

06:1

06:4

03:5

06:4

06:4 06:4

03:5

03:5 06:4

06:4

06:4

06:4

03:8 03:8 03:8 03:8

06:4

06:6

06:6 06:6

06:6

03:1003:1003:1006:6

06:6

03:10

06:6

06:6

03:3

03:3

06:6

06:6

06:5

03:3

03:3

06:5

06:5

03:6

03:6

06:5

06:5

06:5

03:6

03:6

06:5

06:5

06:5

06:7

06:7 06:7

05:26 05:26

06:7

06:7

05:2605:26

06:7

06:7

06:7

06:7

05:27

06:9

06:32 06:33

06:9

06:9

06:31

06:14

06:8

06:8

06:14

06:1406:1406:1406:1206:12

06:14

06:14

06:14

06:1206:1206:1206:30

06:30

06:30

06:30 06:13

06:13 06:13

06:16

06:16

06:13

06:13

06:13

06:13

06:13

06:18 06:18

06:16

06:8

06:8

06:9

06:8

06:8

06:8

06:8

05:25

05:2505:25

05:28

05:28

05:2505:25

05:15

05:15

05:15

05:15

05:15

05:905:9 05:9

05:9

05:9

05:9

05:12

05:12

05:12

05:28

05:28

05:28

05:2805:28

05:28

05:28

06:10

06:10

06:10

06:10 06:10

06:10

06:10

06:1006:10

06:3

05:1405:14

05:14

05:14

05:1405:14

05:19

05:13

05:13 05:13

05:12

05:12 05:2305:12

05:1805:18 05:25

05:11

05:11

05:11 05:24

05:11 05:1105:11

05:10

05:10 05:10

05:10

05:10

06:3

06:11

05:2,4,6,8

05:1,3,5,7

05:1,3,5,7

05:2,4,6,8

05:19

04:1,3,5,7

04:9,11,13,15

04:2,4,6,8 04:2,4,6,8

04:2,4,6,8

04:9,11,13,15

04:9,11,13,15

04:10,12,14,16

03:12,14,16,18

03:12,14,16,18

03:9,11,13,15

01:13,15,17

06:33

05:23

05:20

05:9

05:9

GFCI

GFCI

GFCI

05:29

FPB-01-04

06:30 5

GFCI GFCI

04:26

05:16

GFCI

GFCIGFCI

GFCI

AHU-01-02A

E-401

F12

03:1,4

06:1,2,7 03:7,8 03:3,10

06:4,5,6

06:16,18

06:9,13

06:11

06:11,12.14

05:11,12,13

05:9,15

05:26,27

DDC

CONTROLLER

01:14,16,18

01:25,27,29

03:19

06:30

06:30

EF-01-0105:21

03:9,11,13,15

03:9,11,13,15

03:27, 29, 31, 33

DDC CONTROLLER

04:1,3,5,7

04:10,12,14,16

04:10,12,14,16

05:2,4,6,8 05:2,4,6,8

05:1,3,5,7

03:32,34

03:36,38

05:4,8

05:17

06:35

01:20,22,24

01:1,3,5

GFCI

GFCI

GFCI

GFCI

04:21

SIPRNET

TELECOM

ENCL

06:34

SIPRNET TELECOM

ENCL

06:3,10

05:17,25

05:10,11,15

05:14,19,22

05:14,19

05:29

03:17

03:17

03:19

06:17,19,21,23

04:23,25,27,29

05:30,32,34,36

03:27,29,31,33

SM

06:15

SM

06:15

SM

06:22

SM

06:22

SM

06:22 SM

06:22

SM

06:20

SM

06:20

SM

05:31

VAV-01-02

SM

06:20

SM

06:20

VAV-01-01

SM

VAV-01-02

05:31

SM

05:31

VAV-01-04

01:2,4,6

01:19,21,23

SM

03:15

SM

03:26

01:8,10,12

FPB-01-15

FPB-01-14

FPB-01-12 FPB-01-11 FPB-01-10

FPB-01-09

FPB-01-08

FPB-01-07

FPB-01-03

FPB-01-06

04:1,3,5,7

FPB-01-13

SM

06:15

FPB-01-02

SM

06:15

FPB-01-05

SM

06:20

FPB-01-01

SM

03:15

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

PLAN NORTH

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:5

:0

A

M

E-121

S E

C O

N D

F L O

O R

P O

W E

R A

N D

G R

O U

N D

IN

G

P L A

N

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

K B

O U

R A

S S

A

J W

IT

H

R O

W

M J A

IM

E

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

8'4' 16'0

GENERAL SHEET NOTES:

SHEET KEYNOTES:

1. PROVIDE 3#10, 1#10G SHIELDED WIRE IN 3/4"C.

2. UNDER-COUNTER RECEPTACLE.

3. MOUNT COUNTER TOP RECEPTACLES AT 3'- 6" AFF. (TYP)

4. PROVIDE 3#8 AWG, 1#10G IN 3/4"C.

5. MOUNT TV RECEPTACLE 84" AFF. REFER TO DETAIL H2 ON SHEET T-504.

6. POWER FOR FLOOR BOX MUST BE ROUTED IN SEPARATE CONDUIT FROM

DATA CABLES FOR SECURE OUTLETS SHOWN ON T-121. REFER TO E-501

FOR FLOOR BOX DETAIL.

7. PROVIDE 3#4/0 AWG, 1#4G IN 2-1/2"C.

8. PROVIDE DISCONNECT SWITCH 3P, 30A, FUSED AT 25A, NEMA 1.

9. MOUNT RECEPTACLES ABOVE SINK COUNTERTOP.

10. APPROXIMATE LOCATION IS SHOWN. COORDINATE LOCATION OF JUNCTION

BOXES FOR FUTURE LOADS WITH THE OWNER.

11. JUNCTION BOX INDICATES CONNECTION POINT FOR SYSTEMS FURNITURE

INSTALLED UP AGAINST AN INTERIOR WALL. ROUTE THE CIRCUIT

CONDUCTORS INDICATED INSIDE THE WALL CAVITY TO THE SYSTEMS

FURNITURE CONNECTION POINT - TYPICAL.

12. AHU IS POWERED FROM OUTDOOR CONDENSER. PROVIDE MOTOR RATED

TOGGLE SWITCH MOUNTED ADJACENT TO THE UNIT.

13. PROVIDE DISCONNECT SWITCH, 1P, 30A FUSED AT 15A, NEMA 1.

14. PROVIDE NON-FUSED DISCONNECT SWITCH, 3P, 60A, NEMA 1.

1/8" = 1'-0"C1

SECOND FLOOR POWER AND GROUNDING

PLAN

1. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL

EQUIPMENT.

2. PROVIDE JUNCTION BOXES FOR OPEN OFFICE WORKSTATIONS ABOVE THE

CEILING.

3. PROVIDE 120VAC/24VDC TRANSFORMER FOR VAV(S)..

4. REFER TO E-501 FOR SYSTEM FURNITURE WIRING DETAIL.

5. REFER TO E-601 FOR FEEDER SCHEDULE.

6. PROVIDE EXOTHERMIC WELD FOR STRUCTURAL STEEL AND BOND TO THE

MGB-231-02-001.

7. PROVIDE 200% NEUTRAL FOR COMPUTER CIRCUITS AT SYSTEMS FURNITURE.

PROVIDE ISOLATED EQUIPMENT GROUND FOR COMPUTER CIRCUITS AT

SYSTEMS FURNITURE. REFER TO DETAIL J2 ON E-501 FOR MORE INFORMATION.

8. FOR MULTIPLE WORKSTATIONS ON ONE CIRCUIT WHERE MULTIPLE POWER

POLES ARE USED, SPLICE ABOVE THE CEILING AT THE APPROPRIATE POWER

POLE AND CONTINUE CIRCUIT TO REMAINING POLE.

9. MAKE FINAL ELECTRICAL CONNECTION FOR SYSTEMS FURNITURE CIRCUITS

ABOVE THE CEILING AT THE JUNCTION BOX. PROVIDE EACH WORKSTATION

WITH ONE QUADPLEX FOR COMPUTER LOAD AND ONE DUPLEX FOR HOUSE

POWER.

10. REFER TO TABLE ON THIS SHEET FOR MAXIMUM CABLE DISTANCES FOR

BRANCH CIRCUITS. ALL 20A BRANCH CIRCUITS SHALL BE SIZED BASED UPON

THIS TABLE AND THE DISTANCE LIMITATIONS SET FORTH. IF THE DISTANCE

EXCEEDS THE MAX LIMITATION, A LARGER SIZED CABLE/CONDUIT SHALL BE

USED TO COMPLY WITH THE DISTANCE LIMITATIONS TO THE FURTHEST

LOAD/RECEPTACLE ON THE CIRCUIT. IF TERMINALS OF

RECEPTACLES/EQUIPMENT ARE NOT LISTED FOR THE OVERSIZED

CONDUCTORS, THE CONTRACTOR SHALL PROVIDE SMALLER SPLICED PIGTAILS

WITHIN THE RECEPTACLE/EQUIPMENT BOX. MAKE THE SPLICE AT A JUNCTION

BOX WITH THE OVERSIZED WIRES AT A SUITABLE LOCATION; EITHER ABOVE

THE CEILING WHERE POWER POLES ARE INSTALLED OR AS CLOSE AS

PRACTICAL TO THE LOAD

11. BOND ALL METALLIC PIPES INCLUDING BUT NOT LIMITED TO WATER, FIRE, GAS,

SEWER AND STORM TO MGB-231-02-001.

12. MOUNT MOTOR RATED SWITCHES FOR VAV(S) AND FPB(S) IN ACCORDANCE

WITH THE MANUFACTURER'S RECOMMENDATIONS. REFER TO THE MECHANICAL

PLANS FOR EXACT LOCATIONS OF THE SWITCHES.

20 16 3 6 8 1" 250 577

20 16 3 8 10 1" 161 371

20 16 2 10 10 3/4" 102 236

20 16 1 12 12 3/4" 66 153

120V 277V

# OF

CKT/CONDUIT

PHASE & 100%

NEUTRAL (AWG)

GROUND

CONDUCTOR (AWG)

CONDUIT

MAX DISTANCE IN FEET FOR <= 3% VOLTAGE DROPSIZE OF CB

MAX FULL

LOAD AMPS

LINEAR LOAD BRANCH CIRCUITS

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

FIRST FLOOR

100'-0"

SECOND FLOOR

115'-5 1/2"

F.EE.E

SWBD-002

SWBD PULL SECTION

NEW 3" CONDUITS

EX 4" CONDUITS

EX OUTGOING CONDUITS

NEW 1" CONDUITS

FIRST FLOOR

100'-0"

SECOND FLOOR

115'-5 1/2"

F.EE.E

PANEL E

EX 4" CONDUITS FROM

GENERATOR

EX OUTGOING CONDUITS

EX J-BOX

FIRST FLOOR

100'-0"

FIRST FLOOR

100'-0"

SECOND FLOOR

115'-5 1/2"

DNU - SECOND

FLOOR

115'-5 1/2"

TOP OF MASONRY

@ EXISTING

PARAPET

118'-1 1/2"

SECOND FLOOR

115'-5 1/2"

FIRST FLOOR

100'-0"

SECOND FLOOR

115'-5 1/2"

FIRST FLOOR

100'-0"

2ND FLOOR

EXISTING - TOC

115'-5 1/2"

2ND FLOOR

ADDITION - TOC

115'-5 1/2"

TOP OF EXISTING

PARAPET

118'-3"

1.E

600KW DIESEL GENERATOR

SWBD PULL SECTION

CONTROLS PULLBOX

1" CONTROLS CONDUIT 1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:0

P

M

E-201

O U

T D

O O

R E

L E

C T

R

IC

A L S

E C

T

IO

N S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

K B

O U

R A

S S

A

J W

IT

H

R O

W

M J A

IM

E

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

1/4" = 1'-0"B10

SWBD SECTION

1/4" = 1'-0"J1

PANEL E DEMOLITION SECTION

GENERAL SHEET NOTES:

1. COORDINATE SHUTDOWN OF ENGINE-GENERATOR WITH OWNER AND

WITH PLANNED UTILITY OUTAGE. REFER TO SHEET E-402.

REMOVE PANEL E AND ALL ELECTRICAL CONNECTIONS. CUT EXISTING

4" CONDUITS FROM GENERATOR AND OUTGOING CONDUITS AS

NECESSARY TO A PRE-DETERMINED LOCATION TO ALLOW FOR

INSTALLATION OF NEMA 3R SWITCHBOARD.

2. REFER TO E-121 FOR CONTINUATION OF NEW CONDUITS TO NEW ATS.

3. PROVIDE NEW NEMA 3R SWBD-231-01-002. EXTEND EXISTING 4"

CONDUITS FROM GENERATOR AND OUTGOING CONDUITS TO NEW

SWITCHBOARD. RECONNECT EXISTING CIRCUITS.

4. PROVIDE NEW (3EA) 3" AND (1 EA) 1" RGS CONDUITS FROM

SWBD-231-01-002 WITH MYERS HUBS FOR SEALING AGAINST WATER

INGRESS. APPROXIMATE LOCATION OF PENETRATION INTO THE

SECOND STORY IS SHOWN. COORDINATE EXACT LOCATION WITH

OTHER DISCIPLINES. TRANSITION TO EMT OR OTHER APPROVED

CONDUIT TYPE WITHIN THE BUILDING. REFER TO E-121 FOR

CONTINUATION OF CONDUITS TO ATS-231-02-001.

5. PROVIDE NEMA 3R PULLBOX FOR CONTROLS CONDUIT. MINIMUM

DIMENSIONS ARE 6" X 6" X 6". MAKE PENETRATION INTO THE

GENERATOR ENCLOSURE. DO NOT VOID THE MANUFACTURER'S

WARRANTY.

0 2' 4' 8'

0 2' 4' 8'1/4" = 1'-0"B1

CONTROLS CONDUIT ELEVATION

0 2' 4' 8'

SHEET KEYNOTES:

1. ROUTE CONTROLS CONDUIT ADJACENT TO EXISTING CONDUIT AND

FUEL LINES.

2. SPLICES OF EXISTING CABLES WITHIN SWBD-002 PULL SECTION ARE

PERMITTED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN

NEC ARTICLE 230.46. PROVIDE INSULATED ELECTRICAL LUG TYPE

CONNECTOR OR INDENTOR CRIMP-TYPE. WRAPJOINTS WITH

INSULATING TYPE THAT HAS AN INSULATION AND TEMPERATURE

RATING EQUIVALENT TO THAT OF THE CONDUCTOR.

3. PROVIDE PULL SECTION WITH HINGED OR REMOVABLE COVER.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

J

EF-01-04

J

AHU-01-03A

J

AHU-01-03B

J

UH-01-02

3.E

A.E M

D P

-2 -0

-0

PP-231-02-003

TR-231-02-001

PP-231-02-002

TR-231-02-002

PP-231-02-004

ATS-231-02-001

MGB-01

MGB-01

MGB-01

MGB-01

MGB-231-02-001

PP-231-02-005

05:13

05:13

05:13

05:13

04:18

SBB-231-02-001

03:36,38

03:36,38

03:40

05:11

05:13

05:11

05:11

COMM

ELECTRIC

MGB-01

01:20,22,24

3.E

F.E

06:9

06:9

06:9

06:9

PP-231-02-006

06:9

C

C

C

EQUIPMENT

06:25

06:27

06:29

MGB-01

SBB-231-02-002

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:2

P

M

E-401

E L E

C T

R

IC

A L R

O O

M E

N L A

R G

E D

P L A

N

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

K B

O U

R A

S S

A

J W

IT

H

R O

W

M J A

IM

E

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

2'1' 4'0

GENERAL SHEET NOTES:

1. EQUIPMENT IS MOUNTED 18" AFF UNO.

2. PROVIDE ISOLATED GROUND TYPE RECEPTACLES AND CORRESPONDING

EQUIPMENT GROUNDING CONDUCTORS WITHIN EQUIPMENT ROOM 218.

EQUIPMENT GROUNDING CONDUCTORS ARE REQUIRED TO BE INSULATED.

PROVIDE A DEDICATED EQUIPMENT GROUNDING CONDUCTOR FOR EACH

CIRCUIT. ROUTE THESE EQUIPMENT GROUNDING CONDUCTORS FROM

MDP-231-02-001 GROUND BUS AND TERMINATE AT EACH RECEPTACLE'S

APPROPRIATE TERMINAL. DO NOT TERMINATE THESE EQUIPMENT GROUNDING

CONDUCTORS AT SUBPANELS. METAL RACEWAYS AND BOXES ENCLOSING

THESE CONDUCTORS AND DEVICES MUST BE CONNECTED TO THE EQUIPMENT

GROUNDING CONDUCTORS. COMPLY WITH NEC ARTICLE 250.146(D).

3. BOND ALL METALLIC PIPES INCLUDING BUT NOT LIMITED TO WATER, FIRE, GAS,

SEWER AND STORM TO MGB-231-02-001.

1/2" = 1'-0"D2

ELECTRICAL ROOM ENLARGED PLAN

1/2" = 1'-0"F12

SECOND FLOOR POWER AND GROUNDING

PLAN - EQUIPMENT

2'1' 4'0

SHEET KEYNOTES:

1. AHU IS POWERED BY OUTDOOR CONDENSER. REFER TO E-111 FOR

CONTINUATION OF CIRCUIT. PROVIDE MOTOR RATED TOGGLE SWITCH.

2. ENSURE THAT A NEUTRAL TO GROUND BONDING CONNECTION IS NOT

MADE.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:5

P

M

E-702

P O

W E

R P

A N

E L S

C H

E D

U L E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

K B

O U

R A

S S

A

J W

IT

H

R O

W

M J A

IM

E

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

Notes:

Total Est. Demand Current: 47 A

Total Conn. Current: 60 A

Total Est. Demand: 16,889 VA

Receptacle 19,566 VA 75.55% 14,783 VA Total Conn. Load: 21,672 VA

Power 2,106 VA 100.00% 2,106 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 74 A 65 A 47 A

Total Load: 8,612 VA 7,472 VA 5,588 VA

41 SPACE -- -- 0 VA 0 VA -- -- SPACE 42

39 SPACE -- -- 0 VA 0 VA -- -- SPACE 40

37 SPACE -- -- 0 VA 0 VA -- -- SPACE 38

35 SPACE -- -- 0 VA 0 VA -- -- SPACE 36

33 SPACE -- -- 0 VA 0 VA -- -- SPACE 34

31 SPACE -- -- 0 VA 0 VA -- -- SPACE 32

29 REC - COMP WKSTNS 222 (FUTURE) 20 A 1 0 VA 0 VA -- -- SPACE 30

27 0 VA 0 VA -- -- SPACE 28

25 0 VA 600 VA 1 20 A DDC CONTROLLER 26

REC - COMP WKSTNS 222 (FUTURE) 20 A 3

0 VA 1,176 VA 1 20 A SP-01-01 24

21 EXTERIOR CAMERA 20 A 1 0 VA 230 VA 1 20 A ELEVATOR CAB RECS AND LIGHTING 22

19 SPARE - ROOM 222 20 A 1 0 VA 410 VA 1 20 A REC - ELEVATOR MACHINE ROOM 20

17 REC - ELEVATOR PIT 20 A 1 230 VA 180 VA 1 20 A FDB RCPT 18

15 REC - COMP WKSTNS 222 20 A 1 1,800 VA 1,440 VA 1 20 A REC - COMP WKSTNS 222 16

13 1,200 VA 801 VA 14

11 1,200 VA 801 VA 12

COMP WKSTNS - ROOM 222 20 A 3

1,200 VA 801 VA

3 20 A COMP WKSTNS - ROOM 222

7 REC - COMP WKSTNS 222 20 A 1 1,800 VA 1,800 VA 1 20 A REC - COMP WKSTNS 222 8

5 1,001 VA 1,001 VA 6

3 1,001 VA 1,001 VA 4

COMP WKSTNS - ROOM 222 20 A 3

1,001 VA 1,001 VA

3 20 A COMP WKSTNS - ROOM 222

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes:

Enclosure: NEMA 1 Main Lug Only

Mounting: SURFACE Wires: 5 Mains Rating: 125 A

Supply From: 03 Phases: 3 Mains Type: MLO

Location: ELECTRIC 233 Volts: 120/208V A.I.C. Rating: 18KAIC

Branch Panel: PP-231-02-004

Notes:

Total Est. Demand Current: 53 A

Total Conn. Current: 73 A

Total Est. Demand: 18,964 VA

Receptacle 24,603 VA 70.32% 17,302 VA Total Conn. Load: 26,265 VA

Power 1,662 VA 100.00% 1,662 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 97 A 79 A 50 A

Total Load: 11,201 VA 9,041 VA 6,023 VA

41 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 42

39 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 40

37 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 38

35 SPARE 20 A 1 0 VA 0 VA 1 20 A REC - COMP WKSTNS 230 (FUTURE) 36

33 SPARE 20 A 1 0 VA 0 VA 34

31 VARIABLE AIR VOLUME(S) 20 A 1 240 VA 0 VA 32

29 EF-01-03 20 A 1 822 VA 0 VA

3 20 A REC - COMP WKSTNS 230 (FUTURE)

27 COMP WKSTN - ROOM 242 20 A 1 720 VA 1,800 VA 1 20 A REC - STAIR B/SOUTH CORRIDOR 28

25 REC - SOUTH CORRIDOR 20 A 1 1,440 VA 1,440 VA 1 20 A COMP WKSTN - ROOMS 240/241 26

23 REC - MICROWAVES ROOM 231 20 A 1 360 VA 180 VA 1 20 A AHU-01-01 MAINTENANCE OUTLET 24

21 REC - ICE MAKER/DISPENSER ROOM 231 20 A 1 180 VA 180 VA 1 20 A SIPRNET TELECOM ENCLOSURE 22

19 REC - ROOM 222 20 A 1 540 VA 180 VA 1 20 A REC - UNDERCOUNTER REFRIGERATOR... 20

17 SPARE - ROOM 231 20 A 1 0 VA 360 VA 1 20 A REC - REFRIGERATOR/FREEZER ROOM 231 18

15 REC - 227/228/229 20 A 1 1,260 VA 600 VA 1 20 A DDC CONTROLLER 16

13 REC - 231/232/233 20 A 1 1,620 VA 1,260 VA 1 20 A REC- ROOM 221 14

11 REC - 233/234 20 A 1 1,620 VA 1,080 VA 1 20 A REC - ROOMS 224/225/231 12

9 REC - ROOMS 223/224/236 20 A 1 1,620 VA 1,080 VA 1 20 A REC - ROOM 230 10

7 REC - COMP WKSTNS 222 20 A 1 1,080 VA 1,800 VA 1 20 A REC - COMP WKSTNS 222 8

5 600 VA 1,001 VA 6

3 600 VA 1,001 VA 4

COMP WKSTNS - ROOM 222 20 A 3

600 VA 1,001 VA

3 20 A COMP WKSTNS - ROOM 222

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes:

Enclosure: NEMA 1 MCB Rating: 110 A

Mounting: SURFACE Wires: 5 Mains Rating: 125 A

Supply From: TR02 Phases: 3 Mains Type: MCB

Location: COMM 232 Volts: 120/208V A.I.C. Rating: 10KAIC

Branch Panel: PP-231-02-005

Notes:

Total Est. Demand Current: 58 A

Total Conn. Current: 89 A

Total Est. Demand: 21,002 VA

Receptacle 32,004 VA 65.62% 21,002 VA Total Conn. Load: 32,004 VA

Power 0 VA 0.00% 0 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 102 A 105 A 69 A

Total Load: 11,748 VA 12,036 VA 8,220 VA

41 SPACE -- -- 0 VA 0 VA -- -- SPACE 42

39 SPARE 20 A 1 0 VA 0 VA -- -- SPACE 40

37 SPARE 20 A 1 0 VA 0 VA -- -- SPACE 38

35 SPARE (FUTURE) - ROOM 216 20 A 1 0 VA 0 VA 1 20 A SPARE 36

33 REC - MICROWAVES ROOM 217 20 A 1 360 VA 180 VA 1 20 A SIPRNET TELECOM ENCLOSURE 34

31 REC - REFRIGERATOR/FREEZER ROOM... 20 A 1 180 VA 180 VA 1 20 A REC - ICE MAKER/DISPENSER ROOM 217 32

29 EQUIPMENT RACKS 20 A 1 1,200 VA 1,260 VA 1 20 A CONF ROOM 216 DISPLAY WALL 30

27 EQUIPMENT RACKS 20 A 1 1,200 VA 0 VA 1 20 A SPARE 28

25 EQUIPMENT RACKS 20 A 1 1,200 VA 0 VA 1 20 A SPARE 26

23 REC - COMP WKSTNS 215 (FUTURE) 20 A 1 0 VA 0 VA 1 20 A SPARE 24

21 0 VA 1,728 VA 1 20 A FPB-01-09,10,11,12 22

19 0 VA 1,728 VA 1 20 A FPB-01-05,06,07,08 20

REC - COMP WKSTNS 215 (FUTURE) 20 A 3

0 VA 720 VA 1 20 A COMP WKSTN - ROOM 220 18

15 FPB-01-02,13,14,15 20 A 1 1,728 VA 1,440 VA 1 20 A COMP WKSTN - ROOMS 214/219 16

13 REC - ROOMS 214/219/220 20 A 1 1,620 VA 1,440 VA 1 20 A REC - ROOMS 216/217 14

11 REC - CONF ROOM TABLE ROOM 216 20 A 1 540 VA 900 VA 1 20 A REC - ROOM 216 12

9 REC - ROOMS 217/218 20 A 1 1,620 VA 1,620 VA 1 20 A REC - NORTH/WEST CORRIDOR 10

7 REC - ROOMS 240/241/242 20 A 1 1,620 VA 1,440 VA 1 20 A REC - NORTH/EAST CORRIDOR 8

5 REC - ROOM 210/211/212/213 20 A 1 1,800 VA 1,800 VA 1 20 A REC - ROOMS 208/209/210 6

3 REC - ROOM 215 20 A 1 540 VA 1,620 VA 1 20 A REC - ROOMS 205/206/207 4

1 REC - ROOMS 203/204/205 20 A 1 1,260 VA 1,080 VA 1 20 A REC - ROOMS 201/202 2

CK

T Circuit Description Trip Poles A B C Poles Trip Circuit Description

CK

T

Notes:

Enclosure: NEMA 1 MCB Rating: 125 A

Mounting: SURFACE Wires: 4 Mains Rating: 125 A

Supply From: 03 Phases: 3 Mains Type: MCB

Location: EQUIPMENT 218 Volts: 120/208V A.I.C. Rating: 18KAIC

Branch Panel: PP-231-02-006

Legend:

Total Amps: 91 A 91 A 91 A

Total Load: 25,353 VA 25,353 VA 25,353 VA

41 42

39 40

37 38

35 36

33 34

31 32

29 30

27 28

25 26

23 5,833 VA 24

21 5,833 VA 22

AHU-2 20 A 3

5,833 VA 20

17 5,820 VA 5,833 VA 18

15 5,820 VA 5,833 VA 16

CHP-01-02 30 A 3

5,820 VA 5,833 VA

3 20 A AHU-1

11 1,233 VA 5,820 VA 12

9 1,233 VA 5,820 VA 10

HEAT TRANSFER PACKAGE HTP-1 20 A 3

1,233 VA 5,820 VA

3 30 A CHP-01-01

5 407 VA 407 VA 6

3 407 VA 407 VA 4

EF #1 20 A 3

407 VA 407 VA

3 20 A EF #2

CK

T Circuit Description Trip Poles

A B C A B C

Poles Trip Circuit Description

CK

T

EXISTING MOTOR CONTROL CENTER. NEW WORK IS INDICATED IN BOLD.

Notes:

Enclosure: NEMA 1 MCB Rating: 175 A

Mounting: FLOOR Wires: 3 Mains Rating: 200 A

Supply From: PANEL SW-A Phases: 3 Mains Type: MCB

Location: MECH ROOM NO. 1 038 Volts: 480V A.I.C. Rating: 22

Branch Panel: MCC

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

W

W

W

W

W

W

W

W

W

W

A V

A V

W

J.E

3.E 2.E 1.E4.E5.E6.E7.E8.E9.E

F.E

E.E

A.E

MECHANICAL

ROOM

ELECTRIC

COMM

BREAK/LUNCH

NEW BUSINESS

WOMEN'S RR

MEN'S RR

STOR

ACCESSIBLE RR

ELEVATOR

HALLWAY

PROGRAM MGMT

MECHANICAL

ROOM

STAIR B

OFFICE

OFFICE

OFFICE

HALLWAY

OFFICE

OFFICE

OFFICE

OFFICE

MEETING

ENGINEERING

CHIEF

BRANCH OFFICE

DIRECTOR

MEETING

OFFICE

OFFICE

OFFICE

OFFICE

STAIR C

041 CONFERENCE

ROOM

BREAK/LUNCH

OFFICE

OFFICE

OFFICE

STAIR A

STORAGE

PROGRAM MGMT

T-401

D10

T-401

D2

EQUIPMENT

218 T-402

F3

T-402

F12

H2

T-202

MGB-231-02-001

JANITOR

7 10

H2

T-504

H2

T-202

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

PLAN NORTH

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:3

A

M

T-121

S E

C O

N D

F L O

O R

T E

L E

C O

M M

U N

IC

A

T

IO

N P

L A

N

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

T L O

V V

O R

N

J W

IT

H

R O

W

W H

O W

E N

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

1/8" = 1'-0"B1

SECOND FLOOR TELECOM PLAN

8'4' 16'0

GENERAL SHEET NOTES:

1. ALL PENETRATIONS THROUGH WALLS AND SLABS SHALL BE SEALED AIR TIGHT

(WITH ACOUSTIC / FIRE SEALANT). SEAL CONDUIT STUBS, PIPING STUBS, DUCT

PENETRATIONS, ELECTRICAL JUNCTION BOX OPENINGS, CONTROL WIRING

OPENINGS, GYPSUM BOARD OPENINGS, CONCRETE OPENING, AND PIPING

PENETRATIONS. CAP ALL OPEN CONDUITS.

2. COORDINATE WITH MECHANICAL CONTRACTOR TO ENSURE THAT

TELECOMMUNICATIONS EQUIPMENT DOES NOT BLOCK MAINTENANCE ACCESS

FOR WATER-TO-AIR HEAT PUMPS (WAHP). LOCATION AND MAINTENANCE

CLEARANCE OF WAHPS ARE SHOWN IN MECHANICAL MH SERIES DRAWINGS.

3. COMMUNICATION DROP FACEPLATE TERMINATIONS ARE SHOWN ON T-502.

COORDINATE EXACT SURFACE MOUNT OR WALL/FLOOR OUTLET BOX WITH

BASE COMM.

SHEET KEYNOTES:

1. 2" H X 12" W NIPR BASKET TRAY.

2. 4" H X 5" W SIPR SURFACE MOUNT RACEWAY.

3. POWER FOR FLOOR BOX MUST BE ROUTED IN SEPARATE CONDUIT FROM DATA

CABLES FOR SECURE OUTLETS.

4. CONDUIT, 2", STUBBED 2"-3" BELOW FINISHED CEILING, CONDUIT EXTENDS TO

UNCLASSIFIED CABLE TRAY FOR ROUTING 12 SMF.

5. SURFACE MOUNT CABLE TRAY FOR AV AND DATA CABLES.

6. SURFACE MOUNT CABLE TRAY FOR SECURE DATA DROPS WITHIN THE OPEN

STORAGE AREAS. TRAY SHALL BE MOUNTED AROUND THE WALL AGAINST THE

CEILING WITH VERTICAL RUNS TO CUBICLES.

7. ALL 12 SMF SHALL HAVE A 10 FT MAINTAINANCE LOOP LOCATED IN CABLE

TRAY. CARE MUST BE TAKEN TO ENSURE THE BEND RADIUS IS NOT EXCEEDED.

8. SURFACE MOUNT RACEWAY SHALL BE SIZED TO ACCOMMODATE

MANUFACTURER BEND RADIUS SPECIFICATIONS OF COMMUNICATIONS CABLE

SUPPORTED.

9. ALL EXTERIOR CUBICLE DATA DROPS SHALL BE SURFACE MOUNTED TO WALL

OUTLETS. ALL INTERIOR CUBICLE DATA DROPS SHALL BE ROUTED TO THE

DATA OUTLET LOCATION AND HAVE AN ADDITIONAL 30 FT OF CABLE COILED

UP. THIS WILL ALLOW THE FURNITURE INSTALLERS TO RUN THE CABLE TO

FURNITURE MOUNTED OUTLETS. THE FURNITURE IS NOT PART OF THIS

PROJECT AND WILL BE COMPLETED AFTER THIS PROJECT IS FINISHED.

10. PROVIDE THIS DATA OUTLET IN THE DDC CONTROL PANEL. FIELD COORDINATE

THE LOCATION WITH THE MECHANICAL ROOM.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

SECOND FLOOR

115'-5 1/2"

VERTICAL LADDER TRAY ON WALL,

12"W FROM TELECOM ENCLOSURE

TO FINISHED CEILING

TELECOM ENCLOSURE, 12RU, 23"D, LOCKABLE

FIBER OPTIC PATCH PANEL, 1RU, 12 SC

CABLE MANAGEMENT PANEL, 1RU

FIBER OPTIC PATCH PANEL, 4RU, SC (OM3 MMF)

CABLE MANAGEMENT PANEL, 1RU

END USER EQUIPMENT

FPP-01

CMP-01

FPP-02

CMP-02

A

F F

3 SIPRNET SURFACE

MOUNTED RACEWAY

SIPRNET SURFACE

MOUNTED RACEWAY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:1

A

M

T-202

T E

L E

C O

M E

L E

V A

T

IO

N S

S

IP

R

N E

T

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

T L O

V V

O R

N

J W

IT

H

R O

W

W H

O W

E N

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

1/2" = 1'-0"H2

SIPRNET TELECOMMUNICATIONS

ENCLOSURE IN OPEN STORAGE WORK

AREA

2'1' 4'0

SHEET KEYNOTES:

1. FIELD COORDINATE INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT

BONDING CONDUCTOR TO TELECOMMUNICATIONS ENCLOSURE FROM

PRIMARY BONDING BUSBAR.

2. WALL MOUNTED TELECOMMUNICATION ENCLOSURE.

3. CONDUIT, 2", STUBBED 2"-3" BELOW FINISHED CEILING, CONDUIT EXTENDS TO

UNCLASSIFIED CABLE TRAY FOR ROUTING 12 SMF, APPLY SEALANT TO THE

ANNULAR SPACE BETWEEN CONDUIT AND FINISHED CEILING TO KEEP THE STC

RATING.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

FINISHED CEILING

MOUNT IN-WORK AT SAME

HEIGHT AS ADJACENT WORK

BOXES WITHIN ROOM

CONDUITS STUBBED ABOVE

ACCESSIBLE CEILING SPACE

WHERE INDICATED

FINISHED FLOOR

CONTRACTOR INSTALLED

2 GANG OUTLET BOX;

STUB CONDUIT BELOW

RAISED ACCESS FLOOR

J JJJ JJJ J

BASKET TRAY

2" GROMMET

FINISHED CEILING

SURFACE MOUNT OUTLET BOX

CONDUIT

FINISHED FLOOR

UNLESS SUPPORTING SYSTEMS FURNITURE, ALL NETWORK OUTLETS

SUPPORTING USASOC SHALL BE MOUNTED 72" ABOVE FLOOR LEVEL AND A

MINIMUM OF 6" FROM ANY OUTLET BOX OF A DIFFERENT CLASSIFICATION.

FURTHER CONSIDERATION SHOULD BE TAKEN IN THE SELECTION OF ANY

FURTHER CONSIDERATION SHOULD BE TAKEN IN THE SELECTION OF ANY

FURNITURE OR PARTITIONS THAT WILL BE HOSTING BOTH UNCLASSIFIED

AND CLASSIFIED CABLE RUNS /OUTLET BOX MOUNTING LOCATIONS SO AS

TO ENSURE THE PROPER SEPARATION IAW CNSSAM TEMPEST/1-13.

SIPRNET SURFACE

MOUNTED RACEWAY

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:0

A

M

T-503

T E

L E

C O

M D

E T

A

IL

S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

T L O

V V

O R

N

J W

IT

H

R O

W

W H

O W

E N

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

NTSH1

INSTALLATION OF TYPICAL WORK AREA

OUTLET LOCATIONS DETAIL

NTSA1

AV WALL BOX DETAIL (2-GANG)

NTSH10

INSTALLATION OF TYPICAL SECURE AREA

SURFACE MOUNT OUTLET LOCATIONS

DETAIL

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

CEILING

SIPR LOCKING

OUTLET BOX

ELECTRICAL

BOX AND PLATE

TYPICAL METAL STUD

FLAT PANEL

MOUNT FRAME

WOOD BLOCKING

(FP2) BACK BOX

AV CONDUIT

PER RISER DIAGRAM

80" FLAT PANEL

ON MOUNT

AV POWER CONDUIT

FLOOR

3/4" PLYWOOD BLOCKING

46" x 24"

CEILING

FLOOR

16"

6"

SURFACE MOUNT CABLE TRAY

FOR AV AND DATA CABLES

2 2 GANG SURFACE

MOUNT BOX

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:3

A

M

T-504

T E

L E

C O

M D

E T

A

IL

S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

T L O

V V

O R

N

J W

IT

H

R O

W

W H

O W

E N

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

NTSH2

CONFERENCE ROOM SIDE WALL FLAT

PANEL DETAIL (TYPICAL FOR EACH FLAT

PANEL)

GENERAL SHEET NOTES:

1. METAL STUDS ARE TYPICAL 16" O.C OR 24" O.C.

2. EXACT SIZE OF BLOCKING MAY VARY PENDING POSITION OF METAL STUDS OR

FIELD CONDITIONS OF WALL.

3. WOOD BLOCKING TO BE FIRE RATED.

SHEET KEYNOTES:

1. EXACT MONITOR SIZE AND POSITION ON WALL TO BE FIELD COORDINATED

WITH CONTRACTOR.

2. FIELD COORDINATE AV WALL BOX LOCATION.

3. SURFACE MOUNT RACEWAY SHALL BE SIZED TO ACCOMMODATE

MANUFACTURER BEND RADIUS SPECIFICATIONS OF COMMUNICATIONS CABLE

SUPPORTED

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

SECURITY

BALANCED MAGNETIC SWITCH

DEVICE INTERFACE BOX

ELECTRIFIED MORTISE LOCK

CARD READER OPTIONS:

• 1 - LEVEL 1 CARD READER

• 2 - LEVEL 2 CARD READER W/INTEGRAL

KEYPAD OR SEPARATE KEYPAD

• 3 - LEVEL 3 CARD READER W/KEYPAD

AND BIOMETRICS

• X - SHALL BE REPLACED BY NUMBERS

LISTED ABOVE AS INDICATED ON PLAN

DRAWING

BATTERY

DUAL READER INTERFACE

FIBER OPTIC PATCH PANEL

POWER DISTRIBUTION MODULE

POWER SUPPLY

NETWORK SWITCH

BAR REQUEST TO EXIT

X

INPUT CONTROL MODULE

SURGE SUPPRESSION DATA

SURGE SUPPRESSION POWER

CAMERA JUNCTION BOX

INTELLIGENT SYSTEM CONTROLLER

CJB

ML

BATT

BREX

DRI

FOP

ICM

ISC

NSW

PDM

PS

SSDA

SSP

DIB (COMMUNICATION)

CAMERA JUNCTION BOX

CARD READER

BALANCED MAGNETIC SWITCH

ELECTRIFIED MORTISE LOCK

TAMPER SWITCH

BREX / REX

CAMERA (DATA)

EXTERIOR CAMERA (HEATING)

READER INTERFACE TO CONTROL MODULE /

READER INTERFACE, INPUT CONTROL

MODULE

BASE STANDARD FIBER OPTIC CABLE

CATEGORY 6 DATA CABLE *

300V, #20 AWG, 8 C, SH, PVC

300V, #20 AWG, 1 PR, SH, PVC

300V, #16 AWG, 1 PR, PVC

300V, #18 AWG, 1 PR, SH, PVC

300V, #16 AWG, 1 PR, PVC

CATEGORY 6 DATA CABLE *

300V, #14 AWG, 1 PR, PVC *

300V, #18 AWG, 2 PR, SH, PVC

TO CABLE TYPE

SECURITY CABLE TYPES

REX REQUEST TO EXIT

DIB

JB JUNCTION BOX

SRI SINGLE READER INTERFACE

T TAMPER SWITCH

ABBREVIATIONS

ACS

AWG

BATT

BMS

BREX

C

CCTV

CJB

CR

DIB

DRI

FDB

FOP

IDS

ISC

JBOX

KP

ML

MOT

NSW

NTS

POE

PR

PVC

REQ'D

REX

SH

SRI

T

V

ACCESS CONTROL SYSTEM

AMERICAN WIRE GAUGE

BATTERY

BALANCED MAGNETIC SWITCH

BAR REQUEST TO EXIT

CONDUCTOR

CLOSED CIRCUIT TELEVISION

CAMERA JUNCTION BOX

CARD READER

DEVICE INTERFACE BOX

DUAL READER INTERFACE

FIELD DISTRIBUTION BOX

FIBER OPTIC PATCH PANEL

INTRUSION DETECTION SYSTEM

INTELLIGENT SYSTEM CONTROLLER

JUNCTION BOX

ARM / DISARM KEYPAD

ELECTRIFIED MORTISE LOCK

MOTION SENSOR

NETWORK SWITCH

NOT TO SCALE

POWER OVER ETHERNET

PAIR

POLYVINYL CHLORIDE

REQUIRED

REQUEST TO EXIT

SHIELDED

SINGLE READER INTERFACE

TAMPER SWITCH

VOLT

FDB FIELD DISTRIBUTION BOX

* COORDINATE WITH CONTRACTING OFFICER

ARM / DISARM KEYPAD

360 DEG MOTION DETECTOR

KP

MOTION DETECTOR, KEYPAD 300V, #18 AWG, 2 PR, SH, PVC

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

J B

A T

E S

C A

T E

G O

R Y

C O

D E

CUI / CONTROLLED UNCLASSIFIED INFORMATION

CUI / CONTROLLED UNCLASSIFIED INFORMATION

C

R e v it \l o c a l_

\R

A F

B -B

L D

G -E

W it h ro w jt .r v t

/2

/2

:3

:1

P

M

TY001

S E

C U

R

IT

Y L

E G

E N

D

N O

T E

S

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B L A

C K

A N

D V

E A

T C

H S

P E

C

IA

L P

R O

J E

C T

S C

O R

P

W

T

H S

T R

E E

T S

U

IT

E

O V

E R

L A

N D

P A

R K

K

A N

S A

S

-2

J T

D N

E L S

O N

J W

IT

H

R O

W

N W

H E

A T

L E

Y

D E

C E

M B

E R

W H

N -2

-R

-4

R E

A D

Y T

O A

D V

E R

T

IS

E

R T

A

B L D

G

S

E C

O N

D -F

L O

O R

A D

D

IT

IO

N

F Y

P

N U

H H

Z -3

-8

-0

GENERAL NOTES:

1. ACCESS CONTROL SYSTEM AND INTRUSION DETECTION SYSTEMS ARE CFCI

AND WILL BE FIELD-ROUTED FROM THE SECOND FLOOR INTO THE EXISTING ACS

NETWORK SWITCH(ES) IN ROOM 127.

2. THE BASE HAS SEPARATE INTRUSION DETECTION AND ACCESS CONTROL

SYSTEMS. ALL IDS AND ACS EQUIPMENT IS CFCI. COORDINATE INSTALLATION OF

BOTH SYSTEMS WITH THE CONTRACTING OFFICER.

3. THIS DESIGN ONLY INCLUDES REQUIRED INFRASTRUCTURE FOR CCTV; ALL

CAMERAS, CCTV CABLES, AND MONITORING SYSTEM(S) ARE GFGI. ANY CCTV

EQUIPMENT RELOCATED DUE TO THE SECOND-FLOOR ADDITION WILL BE

ROUTED THROUGH THE FDB ON THE SECOND FLOOR AND CONNECTED TO THE

EXISTING CCTV SYSTEM ON THE FIRST FLOOR. THE CONTRACTOR SHALL

COORDINATE WITH THE CONTRACTING OFFICER/GOVERNMENT FOR THE EXACT

CCTV CAMERAS TO BE RELOCATED. THE CONTRACTOR WILL THEN FIELD-ROUTE

CCTV INFRASTRUCTURE AS NEEDED THROUGH THE FDB INTO THE EXISTING

CCTV NETWORK SWITCH(ES) IN ROOM 127. THE GOVERNMENT WILL SUPPLY

AND INSTALL ALL CCTV CAMERAS AND RELATED CABLES.

4. THE CONTRACTOR SHALL COORDINATE WITH THE END USER AND AN ACS/IDS

VENDOR AND DETERMINE WHICH FIRST FLOOR EQUIPMENT WOULD NEED TO BE

UPDATED/REPLACED IN ORDER TO ACCOMMODATE THE NEW ACS/IDS

EQUIPMENT FOR THE 2ND FLOOR. CONTRACTORS SHOULD DETERMINE THE

BEST METHOD TO ACCOMPLISH THE WORK AS SHOW IN THE PLANS,

SPECIFICATIONS AND DRAWINGS. BID/PROPOSE AS SHOWN IN THE PLANS AND

SPECIFICATIONS.

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

E N

D M

E N

T

F

E B

A-200 BUILDING ELEVATIONS
A-500 PARTITION TYPES & DETAILS
A-505 WALL SECTION DETAILS
E-121 SECOND FLOOR POWER AND GROUNDING PLAN
E-201 OUTDOOR ELECTRICAL SECTIONS
E-401 ELECTRICAL ROOM ENLARGED PLAN
E-702 POWER PANEL SCHEDULE
T-121 SECOND FLOOR TELECOMMUNICATION PLAN
T-202 TELECOM ELEVATIONS - SIPRNET
T-503 TELECOM DETAILS
T-504 TELECOM DETAILS
TY001 SECURITY LEGEND & NOTES

File details come from the government source that posted it. Updated .