W912HN-23-R-4003_DRAWINGS_AMD6.pdf
PDF 2 MB Posted
- Solicitation number
- W912HN23R4003
About this file
This is a synopsis for a solicitation notice for construction services. The U.S. Army Corps of Engineers Savannah District is seeking a firm-fixed-price contract for a $10-25 million project to construct a 20,654 square foot second floor addition to an existing administrative building at Robins Air Force Base in Warner Robins, Georgia. The work includes updating mechanical, plumbing, electrical and unified monitoring control systems for the new addition. The solicitation will be posted on January 13, 2023 and bids are due via PIEE by February 24, 2023. The contract is a 100% small business set-aside under NAICS code 236220 with a size standard of $45 million. The period of performance is 900 calendar days from notice to proceed. A site visit is scheduled for January 30, 2023. Questions are due in accordance with the forthcoming solicitation.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
100'-0"
1.E 10.E
SECOND FLOOR
115'-5 1/2"
T.O. TRUSS @
OUSIDE FACE OF
CMU
129'-1 1/2"
A1
A-301
8.E 9.E7.E6.E5.E4.E3.E2.E
EXISTING LAB BUILDING
/2
H15
A-505
2" / 12" 2" / 12"
FIRST FLOOR
100'-0"
1.E10.E
SECOND FLOOR
115'-5 1/2"
T.O. TRUSS @
OUSIDE FACE OF
CMU
129'-1 1/2"
8.E9.E 7.E 6.E 5.E 4.E 3.E 2.E
EXISTING BUILDING 231 EXISTING LAB BUILDING
/2
/2
3 H15
A-505
22'-10"
L204L208
L210
L209
2" / 12" 2" / 12"
/8
2'-5 15/16" 13'-9 9/16" 1'-11 3/4"
/8
L211
SHEET KEYNOTES:.GENERAL SHEET NOTES:.
1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS,
SEE SHEET A-002.
2. ALIGN NEW VERTICAL REVEAL LOCATIONS WITH
EXISTING VERTICAL REVEALS
1. NOT USED
2. EXISTING BUILDING ENTRANCE CANOPY TO
REMAIN
3. PROVIDE NEW EIFS SYSTEM TO MATCH TEXTURE,
COLOR, AND REVEAL DIMENSIONS TO MATCH
EXISTING FIRST FLOOR CONDITIONS.
4. EXISTING BUILDING SIGNAGE TO REMAIN
5. NOT USED
6. GUTTER, DOWNSPOUT, AND SPLASHBLOCK. TYP
7. STANDING SEAM METAL ROOF
8. EXTERIOR DOOR, (PROVIDE COLOR
INFORMATION)
9. EXTERIOR LOUVER
10. EXISTING BERM
11. EXISTING DOOR, NO WORK
12. EXISTING ANTENNA, RELOCATED TO EXT. FACADE.
REFER TO G-111
13. RECESSED REVEALS. ALIGN WITH EXISTING
REVEALS BELOW AND MATCH EXISTING WIDTH
AND DEPTH.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
U s e rs
\W a l0
\O n e D ri v e
B la c k
V e a tc h \D o c u m e n ts
\R A
F B
-B L D
G -A
W a lk e rR
M .r v t
/2
/2
:4
:3
P
M
A-200
B U
IL
D
IN
G
E L E
V A
T
IO
N S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
S K
E T
C H
U M
B H
E G
A R
T Y
L A
D A
M S
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
1/8" = 1'-0"H1
NORTH BUILDING ELEVATION
1/8" = 1'-0"B1
SOUTH BUILDING ELEVATION
8'4' 16'0
8'4' 16'0
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
SCHEDULED CEILING
5/8" TYPE "X" GWB (LAYERS PER PARTITION NOTES)
METAL STUD @ 24" OC UNO
FINISH FLOOR
HEAD
PLAN
BASE
WALL TYPE A NOTES:
1. (1) LAYER 5/8" TYPE "X" GWB EACH SIDE
2. (2) LAYER 5/8" TYPE "X" GWB EACH SIDE
DEFLECTION TRACK W/ 1/2"
COMPRESSION OR EXTENSION.
SECURED TO BOTTOM OF ROOF TRUSS
OR STRUCTURE ABOVE
BOTTOM TRACK- SET IN CONT. BED OF
ACOUSTICAL SEALANT
FILL STUD CAVITY WITH ACOUSTICAL INSULATION
PER SCHEDULE
5/8" TYPE "X" GWB (LAYERS PER PARTITION NOTES)
HEAD
PLAN
BASE
UNDERSIDE OF
HORIZONTAL SHAFT
WALL ABOVE
DEFLECTION TRACK W/ 2" JOINT WIDTH AND 1/2"
COMPRESSION OR EXTENSION. SECURED TO
UNDERSIDE OF STRUCTURE ABOVE (HEAD WALL DETAIL
HW-D-0638) UNLESS OTHERWISE DETAILED
(1) LAYER 5/8" GWB EACH SIDE, UNO
METAL STUD @ 16" OC
FINISH FLOOR
ISOLATION JOINT
SCHEDULED CEILING
FINISH FLOOR
HEAD
PLAN
BASE
PANEL ANCHOR CLIP
ANGLE SECURED TO
FLOOR DECK
UNDERSIDE OF
STRUCTURE ABOVE
GYP BD FURRING PER SCHEDULE
CMU REINFORCED
PER STRUCTURAL
WALL TYPE M NOTES:
1. PROVIDE 7/8" HAT CHANNEL AND (1) LAYER 5/8" GWB ON ONE SIDE.
2. FIRE RATING BASED ON FULLY GROUTED UNITS
3. INTERIOR (1) LAYER 5/8" GYP BD. ON METAL FURRING
4. PARTIAL HEIGHT KNEE WALL, CAP TOP OF WALL WITH FINISHED 1"x10" NOMINAL WIDE WOOD SILL, QUARTER ROUND EDGES.
BASE AS SCHEDULED
UNDERSIDE OF
STRUCTURE ABOVE
DEFLECTION TRACK W/ 1/2"
COMPRESSION OR EXTENSION.
SECURED TO UNDERSIDE OF
STRUCTURE ABOVE
SCHEDULED CEILING
(1) LAYER 5/8" GWB EACH SIDE
UNLESS NOTED OTHERWISE
METAL STUD @ 16" OC
FINISH FLOOR
FILL STUD CAVITY WITH
ACOUSTICAL INSULATION
PER SCHEDULE
HEAD
PLAN
BASE
(SEE FLOOR PLAN)
WALL WIDTH
WALL TYPE T NOTES:
1. 2 LAYERS OF 5/8" GYP BOARD ON THE INSULATED SIDE OF THE WALL
GENERAL SHEET NOTES:.
1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS, SEE SHEET A-002.
2. ALL FIRE AND/OR SOUND RATED WALLS SHALL EXTEND FROM SLAB TO
UNDERSIDE OF HARD CEILING STRUCTURE OR TRUSS ABOVE. PROVIDE
BRACING AS NECESSARY. DO NOT EXTEND ANY WALLS FULL HEIGHT TO
UNDERSIDE OF SLOPED ROOF. PROVIDE ACOUSTIC/FIRE RATED
SEALED TRANSITIONS FROM WALLS TO HARD CEILING LOCATIONS.
WHERE ACT GRID CEILINGS ARE SHOWN NEAR STC WALLS, NO
ACOUSTIC/FIRE SEALS ARE REQUIRED.
UNDERSIDE OF
STRUCTURE ABOVE
SCHEDULED CEILING
(1) LAYER 5/8" GWB, UNO
METAL STUD @ 16" OC
FINISH FLOOR
FILL STUD CAVITY WITH
ACOUSTICAL INSULATION
PER SCHEDULE
HEAD
PLAN
BASE
6" ABOVE CEILING UNO
WALL TYPE F NOTES:
1. PARTITION NOT REQUIRED TO MEET A SPECIFIED ACOUSTICAL RATING.
2. (2) LAYERS OF 5/8" GYPSUM WALL BOARD
HEAD
PLAN
(SHAFT SIDE)
BASE
UNDERSIDE OF STRUCTURE ABOVE
SCHEDULED CEILING
CH METAL STUD @ 24" OC
FINISH FLOOR
FILL STUD CAVITY WITH ACOUSTICAL INSULATION PER
SCHEDULE
ACOUSTICAL INSULATION IN DEFLECTION TRACK, STC WALLS
ONLY
(1) LAYER 5/8" TYPE "X" GWB, AND (1) LAYER
1" GWB SHAFT LINER ON SHAFT SIDE
DEFLECTION TRACK W/ 2" JOINT WIDTH AND 1/2"
COMPRESSION OR EXTENSION. SECURED TO UNDERSIDE OF
STRUCTURE ABOVE (HEAD WALL DETAIL HW-D-0119)
WALL TYPE H NOTES:
1. FOR STC 50 RATED WALLS, USE (2) LAYERS OF 5/8" GWB.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
U s e rs
\W a l0
\O n e D ri v e
B la c k
V e a tc h \D o c u m e n ts
\R A
F B
-B L D
G -A
W a lk e rR
M .r v t
/2
/2
:4
:3
P
M
A-500
P A
R T
IT
IO
N T
Y P
E S
D
E T
A
IL
S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
S K
E T
C H
U M
B H
E G
A R
T Y
L A
D A
M S
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
WALL
TYPE
WALL
WIDTH
CMU
WIDTH
FIRE
RATING
UL
ASSEMBLY # STC SOUND TEST # NOTE
M2 8" 8" 1 HR - - - 2
M9 9 1/2" 8" 1 HR - - - 1,2,3
M10 1'-1 1/2" 12" 1 HR - - - 1,2,3
M11 8" 8" - - - - 4
WALL
TYPE
WALL
WIDTH
STUD
WIDTH STC
MANUFACTURER'S
SOUND TEST #
INSULATION
THICKNESS NOTES
A1 5 1/4" 4" - - - 1
A3 4 7/8" 3 5/8" 45 USG-150923 3 1/2" 1
A4 6 1/8" 3 5/8" 50 RAL-TL11-073 3 1/2" 2
WALL
TYPE
WALL
WIDTH
STUD
WIDTH
FIRE
RATING
UL
ASSEMBLY # NOTE
B2 7 1/4" 6" 1 HR UL U419
WALL
TYPE
WALL
WIDTH
STUD
WIDTH
INSULATION
THICKNESS NOTE
T1 1'-4 7/8" (2) 4" 3 1/2" 1
T2 1'-5 3/4" (2) 4" 3 1/2"
NTS1
WALL TYPE A - FULL HEIGHT WALLS
NTS2
WALL TYPE B- FIRE RATED WALLS
NTS5
WALL TYPE M - MASONRY FURRED WALLS
NTS6
WALL TYPE T -TOILET CHASE WALLS
WALL
TYPE
WALL
WIDTH
STUD
WIDTH
INSULATION
THICKNESS
FIRE
RATING
FIRE TEST
FULL
HEIGHT NOTE
F1 4 5/8" 4" 4" - 1
F2 5 1/4" 4" 4" - 2
F5 1 1/2" 7/8" 7/8" - 1
NTS3
WALL TYPE F - METAL STUD FURRED WALLS
WALL
TYPE
WALL
WIDTH
STUD
WIDTH
FIRE
RATING
UL ASSEMBLY
# STC
MANUFACTURER'S
SOUND TEST #
INSULATION
THICKNESS NOTE
H2 4 5/8" 4" 1 HR UL U415 - - -
H7 5 1/4" 4" - UL U415 50 RAL-OT-04-019 3 1/2" 1
NTS4
WALL TYPE H - SHAFT WALLS
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
STANDING SEAM
METAL ROOF AND
RIDGE
METAL DECK
RIGID INSULATION,
MIN R-25
GLASS MAT
GYPSUM COVER
BOARD
TRUSS TOP CHORD
RE: STRUCTURAL
1.E
T.O. TRUSS @
OUSIDE FACE OF
CMU
129'-1 1/2"
STANDING SEAM
METAL ROOF
METAL DECK
RIGID INSULATION,
MIN R-25
METAL GUTTER AND
DOWNSPOUT
PREFINISHED METAL
SOFFIT PANEL
FLASHING AND DRIP EDGE
FLASHING AND DRIP EDGE
SOFFIT TRIM & FLASHING
SEALANT
METAL STUD GIRTS,
24" OC MAX
VERTICAL SPACING
STRUCTURAL TRUSS,
RE: STRUCTURAL
NEOPRENE CLOSURE
TRUSS TOP CHORD
CONTINUOUS, BENT PLATE.
REFER TO STRUCTURAL
GLASS MAT GYPSUM
COVER BOARD
SELF-ADHERING POLYMER-
MODIFIED ASPHALT BITUMEN
MEMBRANE UNDERLAYMENT,
SEE ROOF PLAN (A-131)
J.E
STANDING SEAM
METAL ROOF AND
RIDGE
METAL DECK
RIGID INSULATION,
MIN R-25
PREFINISHED METAL
SOFFIT PANEL
FLASHING AND
DRIP EDGE
SOFFIT TRIM &
FLASHING
SEALANT
NEOPRENE DECK
CLOSURE STRIP
METAL STUD GIRTS,
24" OC MAX
VERTICAL SPACING
GLASS MAT
GYPSUM COVER
BOARD
CONTINUOUS, STEEL
ANGLE. REFER TO
STRUCTURAL
SELF-ADHERING
POLYMER-MODIFIED
ASPHALT BITUMEN
MEMBRANE
UNDERLAYMENT, SEE
ROOF PLAN (A-131)
TRUSS RE:
STRUCTURAL
J.E
12" CMU, TOP COURSE
FILLED WITH GROUT
METAL STUD GIRTS, 24" OC
MAX VERTICAL SPACING
1/4" DIA. REINFORCING, SEE
STRUCTURAL
TOP OF CMU
126' 1 1/2"
5/8" GLASS-MAT
BOARD
2" POLYSTYRENE
INSULATION
BOARD
STUCCO FINISH
OVER REINFORCING
MESH
TRUSS RE: STRUCTURAL
FLUID APPLIED
AIR BARRIER
J.E
TOP OF MASONRY
@ EXISTING
PARAPET
118'-1 1/2"
12" CMU
EXPANSION
JOINT, FLASHING,
AND SEALANT
2" POLYSTYRENE
INSULATION
BOARD
STUCCO FINISH
OVER REINFORCING
MESH
EXISTING
PARAPET
WEEPS PER EIFS
MANUFACTURER
STD DETAILS
EXISTING STUCCO
FINISH OVER CMU.
FIELD VERIFY WALL
THICKNESS AND
ADJUST NEW EIFS
INSULATION THICKNESS
ACCORDINGLY. INFORM
ARCHITECT IF
THICKNESS WILL BE
LESS THAN 2'', TYP
A L
IG
N
FLUID APPLIED
AIR BARRIER
GENERAL SHEET NOTES:.
1. FOR GENERAL NOTES, LEGENDS, ABBREVIATIONS, SEE SHEET A-002.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
U s e rs
\W a l0
\O n e D ri v e
B la c k
V e a tc h \D o c u m e n ts
\R A
F B
-B L D
G -A
W a lk e rR
M .r v t
/2
/2
:4
:3
P
M
A-505
W A
L L S
E C
T
IO
N D
E T
A
IL
S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
S K
E T
C H
U M
B H
E G
A R
T Y
L A
D A
M S
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
3" = 1'-0"H1
BUILDING SECTION DETAIL - RIDGE
3" = 1'-0"B1
SECTION DETAIL @ EAVE
3" = 1'-0"B11
SECTION DETAIL @ RAKE
3" = 1'-0"H8
WALL SECTION DETAIL - T.O.M.
3" = 1'-0"H15
WALL SECTION DETAIL - B.O.M.
1'0 6"3" 1'0 6"3" 1'0 6"3"
1'0 6"3" 1'0 6"3"
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
J
AHU-01-01
J
BLR-01-01
J
DOAS-01-01
J
HWP-01-02
J
HWP-01-01
J
J
EF-01-03
J
AHU-01-02B
J
J J
J
UH-01-03 J
UH-01-01
J
EF-01-02
J
J
J
J
J
J
J
J J J
J
J J
J
J
J
J
J J J
JJ
J
SPARE -
ROOM
J
SPARE -
ROOM
J
SPARE -
ROOM
J
SPARE
(FUTURE)
- ROOM
J
SPARE
(FUTURE)
- ROOM
J
EXTERIOR
CAMERA
J
J
J.E
3.E 2.E 1.E4.E5.E6.E7.E8.E9.E
F.E
E.E
A.E
E-401
D2
ELECTRIC
COMM
BREAK/LUNCH
MECHANICAL
ROOM
PP-231-02-001
PROGRAM MGMT
PROGRAM MGMT
STAIR B
PROGRAM MGMT
HALLWAY
STAIR C
CONFERENCE
ROOM
STOR
ACCESSIBLE RR
STORAGE
EQUIPMENT
OFFICE
OFFICE
STAIR A
JANITOR
OFFICE
BREAK/LUNCH
NEW BUSINESS
MECHANICAL
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
MEETING
ENGINEERING
CHIEF
BRANCH OFFICE
DIRECTOR
MEETING
209 OFFICE
OFFICE
OFFICE
OFFICE
HALLWAY
PROGRAM MGMT
WOMEN'S RR
MEN'S RR
ELEVATOR
OFFICE
OFFICE
OFFICE
01:1,3,5
NMR
05:28
05:15
05:25 05:15
06:2
06:2
03:1
03:1
06:2
06:2
06:2
03:1
06:2
06:1
06:1
06:1
03:4
03:4 06:1
06:1
03:4
03:4
06:1
06:4
03:5
06:4
06:4 06:4
03:5
03:5 06:4
06:4
06:4
06:4
03:8 03:8 03:8 03:8
06:4
06:6
06:6 06:6
06:6
03:1003:1003:1006:6
06:6
03:10
06:6
06:6
03:3
03:3
06:6
06:6
06:5
03:3
03:3
06:5
06:5
03:6
03:6
06:5
06:5
06:5
03:6
03:6
06:5
06:5
06:5
06:7
06:7 06:7
05:26 05:26
06:7
06:7
05:2605:26
06:7
06:7
06:7
06:7
05:27
06:9
06:32 06:33
06:9
06:9
06:31
06:14
06:8
06:8
06:14
06:1406:1406:1406:1206:12
06:14
06:14
06:14
06:1206:1206:1206:30
06:30
06:30
06:30 06:13
06:13 06:13
06:16
06:16
06:13
06:13
06:13
06:13
06:13
06:18 06:18
06:16
06:8
06:8
06:9
06:8
06:8
06:8
06:8
05:25
05:2505:25
05:28
05:28
05:2505:25
05:15
05:15
05:15
05:15
05:15
05:905:9 05:9
05:9
05:9
05:9
05:12
05:12
05:12
05:28
05:28
05:28
05:2805:28
05:28
05:28
06:10
06:10
06:10
06:10 06:10
06:10
06:10
06:1006:10
06:3
05:1405:14
05:14
05:14
05:1405:14
05:19
05:13
05:13 05:13
05:12
05:12 05:2305:12
05:1805:18 05:25
05:11
05:11
05:11 05:24
05:11 05:1105:11
05:10
05:10 05:10
05:10
05:10
06:3
06:11
05:2,4,6,8
05:1,3,5,7
05:1,3,5,7
05:2,4,6,8
05:19
04:1,3,5,7
04:9,11,13,15
04:2,4,6,8 04:2,4,6,8
04:2,4,6,8
04:9,11,13,15
04:9,11,13,15
04:10,12,14,16
03:12,14,16,18
03:12,14,16,18
03:9,11,13,15
01:13,15,17
06:33
05:23
05:20
05:9
05:9
GFCI
GFCI
GFCI
05:29
FPB-01-04
06:30 5
GFCI GFCI
04:26
05:16
GFCI
GFCIGFCI
GFCI
AHU-01-02A
E-401
F12
03:1,4
06:1,2,7 03:7,8 03:3,10
06:4,5,6
06:16,18
06:9,13
06:11
06:11,12.14
05:11,12,13
05:9,15
05:26,27
DDC
CONTROLLER
01:14,16,18
01:25,27,29
03:19
06:30
06:30
EF-01-0105:21
03:9,11,13,15
03:9,11,13,15
03:27, 29, 31, 33
DDC CONTROLLER
04:1,3,5,7
04:10,12,14,16
04:10,12,14,16
05:2,4,6,8 05:2,4,6,8
05:1,3,5,7
03:32,34
03:36,38
05:4,8
05:17
06:35
01:20,22,24
01:1,3,5
GFCI
GFCI
GFCI
GFCI
04:21
SIPRNET
TELECOM
ENCL
06:34
SIPRNET TELECOM
ENCL
06:3,10
05:17,25
05:10,11,15
05:14,19,22
05:14,19
05:29
03:17
03:17
03:19
06:17,19,21,23
04:23,25,27,29
05:30,32,34,36
03:27,29,31,33
SM
06:15
SM
06:15
SM
06:22
SM
06:22
SM
06:22 SM
06:22
SM
06:20
SM
06:20
SM
05:31
VAV-01-02
SM
06:20
SM
06:20
VAV-01-01
SM
VAV-01-02
05:31
SM
05:31
VAV-01-04
01:2,4,6
01:19,21,23
SM
03:15
SM
03:26
01:8,10,12
FPB-01-15
FPB-01-14
FPB-01-12 FPB-01-11 FPB-01-10
FPB-01-09
FPB-01-08
FPB-01-07
FPB-01-03
FPB-01-06
04:1,3,5,7
FPB-01-13
SM
06:15
FPB-01-02
SM
06:15
FPB-01-05
SM
06:20
FPB-01-01
SM
03:15
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
PLAN NORTH
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:5
:0
A
M
E-121
S E
C O
N D
F L O
O R
P O
W E
R A
N D
G R
O U
N D
IN
G
P L A
N
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
K B
O U
R A
S S
A
J W
IT
H
R O
W
M J A
IM
E
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
8'4' 16'0
GENERAL SHEET NOTES:
SHEET KEYNOTES:
1. PROVIDE 3#10, 1#10G SHIELDED WIRE IN 3/4"C.
2. UNDER-COUNTER RECEPTACLE.
3. MOUNT COUNTER TOP RECEPTACLES AT 3'- 6" AFF. (TYP)
4. PROVIDE 3#8 AWG, 1#10G IN 3/4"C.
5. MOUNT TV RECEPTACLE 84" AFF. REFER TO DETAIL H2 ON SHEET T-504.
6. POWER FOR FLOOR BOX MUST BE ROUTED IN SEPARATE CONDUIT FROM
DATA CABLES FOR SECURE OUTLETS SHOWN ON T-121. REFER TO E-501
FOR FLOOR BOX DETAIL.
7. PROVIDE 3#4/0 AWG, 1#4G IN 2-1/2"C.
8. PROVIDE DISCONNECT SWITCH 3P, 30A, FUSED AT 25A, NEMA 1.
9. MOUNT RECEPTACLES ABOVE SINK COUNTERTOP.
10. APPROXIMATE LOCATION IS SHOWN. COORDINATE LOCATION OF JUNCTION
BOXES FOR FUTURE LOADS WITH THE OWNER.
11. JUNCTION BOX INDICATES CONNECTION POINT FOR SYSTEMS FURNITURE
INSTALLED UP AGAINST AN INTERIOR WALL. ROUTE THE CIRCUIT
CONDUCTORS INDICATED INSIDE THE WALL CAVITY TO THE SYSTEMS
FURNITURE CONNECTION POINT - TYPICAL.
12. AHU IS POWERED FROM OUTDOOR CONDENSER. PROVIDE MOTOR RATED
TOGGLE SWITCH MOUNTED ADJACENT TO THE UNIT.
13. PROVIDE DISCONNECT SWITCH, 1P, 30A FUSED AT 15A, NEMA 1.
14. PROVIDE NON-FUSED DISCONNECT SWITCH, 3P, 60A, NEMA 1.
1/8" = 1'-0"C1
SECOND FLOOR POWER AND GROUNDING
PLAN
1. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL
EQUIPMENT.
2. PROVIDE JUNCTION BOXES FOR OPEN OFFICE WORKSTATIONS ABOVE THE
CEILING.
3. PROVIDE 120VAC/24VDC TRANSFORMER FOR VAV(S)..
4. REFER TO E-501 FOR SYSTEM FURNITURE WIRING DETAIL.
5. REFER TO E-601 FOR FEEDER SCHEDULE.
6. PROVIDE EXOTHERMIC WELD FOR STRUCTURAL STEEL AND BOND TO THE
MGB-231-02-001.
7. PROVIDE 200% NEUTRAL FOR COMPUTER CIRCUITS AT SYSTEMS FURNITURE.
PROVIDE ISOLATED EQUIPMENT GROUND FOR COMPUTER CIRCUITS AT
SYSTEMS FURNITURE. REFER TO DETAIL J2 ON E-501 FOR MORE INFORMATION.
8. FOR MULTIPLE WORKSTATIONS ON ONE CIRCUIT WHERE MULTIPLE POWER
POLES ARE USED, SPLICE ABOVE THE CEILING AT THE APPROPRIATE POWER
POLE AND CONTINUE CIRCUIT TO REMAINING POLE.
9. MAKE FINAL ELECTRICAL CONNECTION FOR SYSTEMS FURNITURE CIRCUITS
ABOVE THE CEILING AT THE JUNCTION BOX. PROVIDE EACH WORKSTATION
WITH ONE QUADPLEX FOR COMPUTER LOAD AND ONE DUPLEX FOR HOUSE
POWER.
10. REFER TO TABLE ON THIS SHEET FOR MAXIMUM CABLE DISTANCES FOR
BRANCH CIRCUITS. ALL 20A BRANCH CIRCUITS SHALL BE SIZED BASED UPON
THIS TABLE AND THE DISTANCE LIMITATIONS SET FORTH. IF THE DISTANCE
EXCEEDS THE MAX LIMITATION, A LARGER SIZED CABLE/CONDUIT SHALL BE
USED TO COMPLY WITH THE DISTANCE LIMITATIONS TO THE FURTHEST
LOAD/RECEPTACLE ON THE CIRCUIT. IF TERMINALS OF
RECEPTACLES/EQUIPMENT ARE NOT LISTED FOR THE OVERSIZED
CONDUCTORS, THE CONTRACTOR SHALL PROVIDE SMALLER SPLICED PIGTAILS
WITHIN THE RECEPTACLE/EQUIPMENT BOX. MAKE THE SPLICE AT A JUNCTION
BOX WITH THE OVERSIZED WIRES AT A SUITABLE LOCATION; EITHER ABOVE
THE CEILING WHERE POWER POLES ARE INSTALLED OR AS CLOSE AS
PRACTICAL TO THE LOAD
11. BOND ALL METALLIC PIPES INCLUDING BUT NOT LIMITED TO WATER, FIRE, GAS,
SEWER AND STORM TO MGB-231-02-001.
12. MOUNT MOTOR RATED SWITCHES FOR VAV(S) AND FPB(S) IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS. REFER TO THE MECHANICAL
PLANS FOR EXACT LOCATIONS OF THE SWITCHES.
20 16 3 6 8 1" 250 577
20 16 3 8 10 1" 161 371
20 16 2 10 10 3/4" 102 236
20 16 1 12 12 3/4" 66 153
120V 277V
# OF
CKT/CONDUIT
PHASE & 100%
NEUTRAL (AWG)
GROUND
CONDUCTOR (AWG)
CONDUIT
MAX DISTANCE IN FEET FOR <= 3% VOLTAGE DROPSIZE OF CB
MAX FULL
LOAD AMPS
LINEAR LOAD BRANCH CIRCUITS
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
FIRST FLOOR
100'-0"
SECOND FLOOR
115'-5 1/2"
F.EE.E
SWBD-002
SWBD PULL SECTION
NEW 3" CONDUITS
EX 4" CONDUITS
EX OUTGOING CONDUITS
NEW 1" CONDUITS
FIRST FLOOR
100'-0"
SECOND FLOOR
115'-5 1/2"
F.EE.E
PANEL E
EX 4" CONDUITS FROM
GENERATOR
EX OUTGOING CONDUITS
EX J-BOX
FIRST FLOOR
100'-0"
FIRST FLOOR
100'-0"
SECOND FLOOR
115'-5 1/2"
DNU - SECOND
FLOOR
115'-5 1/2"
TOP OF MASONRY
@ EXISTING
PARAPET
118'-1 1/2"
SECOND FLOOR
115'-5 1/2"
FIRST FLOOR
100'-0"
SECOND FLOOR
115'-5 1/2"
FIRST FLOOR
100'-0"
2ND FLOOR
EXISTING - TOC
115'-5 1/2"
2ND FLOOR
ADDITION - TOC
115'-5 1/2"
TOP OF EXISTING
PARAPET
118'-3"
1.E
600KW DIESEL GENERATOR
SWBD PULL SECTION
CONTROLS PULLBOX
1" CONTROLS CONDUIT 1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:0
P
M
E-201
O U
T D
O O
R E
L E
C T
R
IC
A L S
E C
T
IO
N S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
K B
O U
R A
S S
A
J W
IT
H
R O
W
M J A
IM
E
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
1/4" = 1'-0"B10
SWBD SECTION
1/4" = 1'-0"J1
PANEL E DEMOLITION SECTION
GENERAL SHEET NOTES:
1. COORDINATE SHUTDOWN OF ENGINE-GENERATOR WITH OWNER AND
WITH PLANNED UTILITY OUTAGE. REFER TO SHEET E-402.
REMOVE PANEL E AND ALL ELECTRICAL CONNECTIONS. CUT EXISTING
4" CONDUITS FROM GENERATOR AND OUTGOING CONDUITS AS
NECESSARY TO A PRE-DETERMINED LOCATION TO ALLOW FOR
INSTALLATION OF NEMA 3R SWITCHBOARD.
2. REFER TO E-121 FOR CONTINUATION OF NEW CONDUITS TO NEW ATS.
3. PROVIDE NEW NEMA 3R SWBD-231-01-002. EXTEND EXISTING 4"
CONDUITS FROM GENERATOR AND OUTGOING CONDUITS TO NEW
SWITCHBOARD. RECONNECT EXISTING CIRCUITS.
4. PROVIDE NEW (3EA) 3" AND (1 EA) 1" RGS CONDUITS FROM
SWBD-231-01-002 WITH MYERS HUBS FOR SEALING AGAINST WATER
INGRESS. APPROXIMATE LOCATION OF PENETRATION INTO THE
SECOND STORY IS SHOWN. COORDINATE EXACT LOCATION WITH
OTHER DISCIPLINES. TRANSITION TO EMT OR OTHER APPROVED
CONDUIT TYPE WITHIN THE BUILDING. REFER TO E-121 FOR
CONTINUATION OF CONDUITS TO ATS-231-02-001.
5. PROVIDE NEMA 3R PULLBOX FOR CONTROLS CONDUIT. MINIMUM
DIMENSIONS ARE 6" X 6" X 6". MAKE PENETRATION INTO THE
GENERATOR ENCLOSURE. DO NOT VOID THE MANUFACTURER'S
WARRANTY.
0 2' 4' 8'
0 2' 4' 8'1/4" = 1'-0"B1
CONTROLS CONDUIT ELEVATION
0 2' 4' 8'
SHEET KEYNOTES:
1. ROUTE CONTROLS CONDUIT ADJACENT TO EXISTING CONDUIT AND
FUEL LINES.
2. SPLICES OF EXISTING CABLES WITHIN SWBD-002 PULL SECTION ARE
PERMITTED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN
NEC ARTICLE 230.46. PROVIDE INSULATED ELECTRICAL LUG TYPE
CONNECTOR OR INDENTOR CRIMP-TYPE. WRAPJOINTS WITH
INSULATING TYPE THAT HAS AN INSULATION AND TEMPERATURE
RATING EQUIVALENT TO THAT OF THE CONDUCTOR.
3. PROVIDE PULL SECTION WITH HINGED OR REMOVABLE COVER.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
J
EF-01-04
J
AHU-01-03A
J
AHU-01-03B
J
UH-01-02
3.E
A.E M
D P
-2 -0
-0
PP-231-02-003
TR-231-02-001
PP-231-02-002
TR-231-02-002
PP-231-02-004
ATS-231-02-001
MGB-01
MGB-01
MGB-01
MGB-01
MGB-231-02-001
PP-231-02-005
05:13
05:13
05:13
05:13
04:18
SBB-231-02-001
03:36,38
03:36,38
03:40
05:11
05:13
05:11
05:11
COMM
ELECTRIC
MGB-01
01:20,22,24
3.E
F.E
06:9
06:9
06:9
06:9
PP-231-02-006
06:9
C
C
C
EQUIPMENT
06:25
06:27
06:29
MGB-01
SBB-231-02-002
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:2
P
M
E-401
E L E
C T
R
IC
A L R
O O
M E
N L A
R G
E D
P L A
N
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
K B
O U
R A
S S
A
J W
IT
H
R O
W
M J A
IM
E
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
2'1' 4'0
GENERAL SHEET NOTES:
1. EQUIPMENT IS MOUNTED 18" AFF UNO.
2. PROVIDE ISOLATED GROUND TYPE RECEPTACLES AND CORRESPONDING
EQUIPMENT GROUNDING CONDUCTORS WITHIN EQUIPMENT ROOM 218.
EQUIPMENT GROUNDING CONDUCTORS ARE REQUIRED TO BE INSULATED.
PROVIDE A DEDICATED EQUIPMENT GROUNDING CONDUCTOR FOR EACH
CIRCUIT. ROUTE THESE EQUIPMENT GROUNDING CONDUCTORS FROM
MDP-231-02-001 GROUND BUS AND TERMINATE AT EACH RECEPTACLE'S
APPROPRIATE TERMINAL. DO NOT TERMINATE THESE EQUIPMENT GROUNDING
CONDUCTORS AT SUBPANELS. METAL RACEWAYS AND BOXES ENCLOSING
THESE CONDUCTORS AND DEVICES MUST BE CONNECTED TO THE EQUIPMENT
GROUNDING CONDUCTORS. COMPLY WITH NEC ARTICLE 250.146(D).
3. BOND ALL METALLIC PIPES INCLUDING BUT NOT LIMITED TO WATER, FIRE, GAS,
SEWER AND STORM TO MGB-231-02-001.
1/2" = 1'-0"D2
ELECTRICAL ROOM ENLARGED PLAN
1/2" = 1'-0"F12
SECOND FLOOR POWER AND GROUNDING
PLAN - EQUIPMENT
2'1' 4'0
SHEET KEYNOTES:
1. AHU IS POWERED BY OUTDOOR CONDENSER. REFER TO E-111 FOR
CONTINUATION OF CIRCUIT. PROVIDE MOTOR RATED TOGGLE SWITCH.
2. ENSURE THAT A NEUTRAL TO GROUND BONDING CONNECTION IS NOT
MADE.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:5
P
M
E-702
P O
W E
R P
A N
E L S
C H
E D
U L E
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
K B
O U
R A
S S
A
J W
IT
H
R O
W
M J A
IM
E
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
Notes:
Total Est. Demand Current: 47 A
Total Conn. Current: 60 A
Total Est. Demand: 16,889 VA
Receptacle 19,566 VA 75.55% 14,783 VA Total Conn. Load: 21,672 VA
Power 2,106 VA 100.00% 2,106 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 74 A 65 A 47 A
Total Load: 8,612 VA 7,472 VA 5,588 VA
41 SPACE -- -- 0 VA 0 VA -- -- SPACE 42
39 SPACE -- -- 0 VA 0 VA -- -- SPACE 40
37 SPACE -- -- 0 VA 0 VA -- -- SPACE 38
35 SPACE -- -- 0 VA 0 VA -- -- SPACE 36
33 SPACE -- -- 0 VA 0 VA -- -- SPACE 34
31 SPACE -- -- 0 VA 0 VA -- -- SPACE 32
29 REC - COMP WKSTNS 222 (FUTURE) 20 A 1 0 VA 0 VA -- -- SPACE 30
27 0 VA 0 VA -- -- SPACE 28
25 0 VA 600 VA 1 20 A DDC CONTROLLER 26
REC - COMP WKSTNS 222 (FUTURE) 20 A 3
0 VA 1,176 VA 1 20 A SP-01-01 24
21 EXTERIOR CAMERA 20 A 1 0 VA 230 VA 1 20 A ELEVATOR CAB RECS AND LIGHTING 22
19 SPARE - ROOM 222 20 A 1 0 VA 410 VA 1 20 A REC - ELEVATOR MACHINE ROOM 20
17 REC - ELEVATOR PIT 20 A 1 230 VA 180 VA 1 20 A FDB RCPT 18
15 REC - COMP WKSTNS 222 20 A 1 1,800 VA 1,440 VA 1 20 A REC - COMP WKSTNS 222 16
13 1,200 VA 801 VA 14
11 1,200 VA 801 VA 12
COMP WKSTNS - ROOM 222 20 A 3
1,200 VA 801 VA
3 20 A COMP WKSTNS - ROOM 222
7 REC - COMP WKSTNS 222 20 A 1 1,800 VA 1,800 VA 1 20 A REC - COMP WKSTNS 222 8
5 1,001 VA 1,001 VA 6
3 1,001 VA 1,001 VA 4
COMP WKSTNS - ROOM 222 20 A 3
1,001 VA 1,001 VA
3 20 A COMP WKSTNS - ROOM 222
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: NEMA 1 Main Lug Only
Mounting: SURFACE Wires: 5 Mains Rating: 125 A
Supply From: 03 Phases: 3 Mains Type: MLO
Location: ELECTRIC 233 Volts: 120/208V A.I.C. Rating: 18KAIC
Branch Panel: PP-231-02-004
Notes:
Total Est. Demand Current: 53 A
Total Conn. Current: 73 A
Total Est. Demand: 18,964 VA
Receptacle 24,603 VA 70.32% 17,302 VA Total Conn. Load: 26,265 VA
Power 1,662 VA 100.00% 1,662 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 97 A 79 A 50 A
Total Load: 11,201 VA 9,041 VA 6,023 VA
41 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 42
39 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 40
37 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 38
35 SPARE 20 A 1 0 VA 0 VA 1 20 A REC - COMP WKSTNS 230 (FUTURE) 36
33 SPARE 20 A 1 0 VA 0 VA 34
31 VARIABLE AIR VOLUME(S) 20 A 1 240 VA 0 VA 32
29 EF-01-03 20 A 1 822 VA 0 VA
3 20 A REC - COMP WKSTNS 230 (FUTURE)
27 COMP WKSTN - ROOM 242 20 A 1 720 VA 1,800 VA 1 20 A REC - STAIR B/SOUTH CORRIDOR 28
25 REC - SOUTH CORRIDOR 20 A 1 1,440 VA 1,440 VA 1 20 A COMP WKSTN - ROOMS 240/241 26
23 REC - MICROWAVES ROOM 231 20 A 1 360 VA 180 VA 1 20 A AHU-01-01 MAINTENANCE OUTLET 24
21 REC - ICE MAKER/DISPENSER ROOM 231 20 A 1 180 VA 180 VA 1 20 A SIPRNET TELECOM ENCLOSURE 22
19 REC - ROOM 222 20 A 1 540 VA 180 VA 1 20 A REC - UNDERCOUNTER REFRIGERATOR... 20
17 SPARE - ROOM 231 20 A 1 0 VA 360 VA 1 20 A REC - REFRIGERATOR/FREEZER ROOM 231 18
15 REC - 227/228/229 20 A 1 1,260 VA 600 VA 1 20 A DDC CONTROLLER 16
13 REC - 231/232/233 20 A 1 1,620 VA 1,260 VA 1 20 A REC- ROOM 221 14
11 REC - 233/234 20 A 1 1,620 VA 1,080 VA 1 20 A REC - ROOMS 224/225/231 12
9 REC - ROOMS 223/224/236 20 A 1 1,620 VA 1,080 VA 1 20 A REC - ROOM 230 10
7 REC - COMP WKSTNS 222 20 A 1 1,080 VA 1,800 VA 1 20 A REC - COMP WKSTNS 222 8
5 600 VA 1,001 VA 6
3 600 VA 1,001 VA 4
COMP WKSTNS - ROOM 222 20 A 3
600 VA 1,001 VA
3 20 A COMP WKSTNS - ROOM 222
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: NEMA 1 MCB Rating: 110 A
Mounting: SURFACE Wires: 5 Mains Rating: 125 A
Supply From: TR02 Phases: 3 Mains Type: MCB
Location: COMM 232 Volts: 120/208V A.I.C. Rating: 10KAIC
Branch Panel: PP-231-02-005
Notes:
Total Est. Demand Current: 58 A
Total Conn. Current: 89 A
Total Est. Demand: 21,002 VA
Receptacle 32,004 VA 65.62% 21,002 VA Total Conn. Load: 32,004 VA
Power 0 VA 0.00% 0 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 102 A 105 A 69 A
Total Load: 11,748 VA 12,036 VA 8,220 VA
41 SPACE -- -- 0 VA 0 VA -- -- SPACE 42
39 SPARE 20 A 1 0 VA 0 VA -- -- SPACE 40
37 SPARE 20 A 1 0 VA 0 VA -- -- SPACE 38
35 SPARE (FUTURE) - ROOM 216 20 A 1 0 VA 0 VA 1 20 A SPARE 36
33 REC - MICROWAVES ROOM 217 20 A 1 360 VA 180 VA 1 20 A SIPRNET TELECOM ENCLOSURE 34
31 REC - REFRIGERATOR/FREEZER ROOM... 20 A 1 180 VA 180 VA 1 20 A REC - ICE MAKER/DISPENSER ROOM 217 32
29 EQUIPMENT RACKS 20 A 1 1,200 VA 1,260 VA 1 20 A CONF ROOM 216 DISPLAY WALL 30
27 EQUIPMENT RACKS 20 A 1 1,200 VA 0 VA 1 20 A SPARE 28
25 EQUIPMENT RACKS 20 A 1 1,200 VA 0 VA 1 20 A SPARE 26
23 REC - COMP WKSTNS 215 (FUTURE) 20 A 1 0 VA 0 VA 1 20 A SPARE 24
21 0 VA 1,728 VA 1 20 A FPB-01-09,10,11,12 22
19 0 VA 1,728 VA 1 20 A FPB-01-05,06,07,08 20
REC - COMP WKSTNS 215 (FUTURE) 20 A 3
0 VA 720 VA 1 20 A COMP WKSTN - ROOM 220 18
15 FPB-01-02,13,14,15 20 A 1 1,728 VA 1,440 VA 1 20 A COMP WKSTN - ROOMS 214/219 16
13 REC - ROOMS 214/219/220 20 A 1 1,620 VA 1,440 VA 1 20 A REC - ROOMS 216/217 14
11 REC - CONF ROOM TABLE ROOM 216 20 A 1 540 VA 900 VA 1 20 A REC - ROOM 216 12
9 REC - ROOMS 217/218 20 A 1 1,620 VA 1,620 VA 1 20 A REC - NORTH/WEST CORRIDOR 10
7 REC - ROOMS 240/241/242 20 A 1 1,620 VA 1,440 VA 1 20 A REC - NORTH/EAST CORRIDOR 8
5 REC - ROOM 210/211/212/213 20 A 1 1,800 VA 1,800 VA 1 20 A REC - ROOMS 208/209/210 6
3 REC - ROOM 215 20 A 1 540 VA 1,620 VA 1 20 A REC - ROOMS 205/206/207 4
1 REC - ROOMS 203/204/205 20 A 1 1,260 VA 1,080 VA 1 20 A REC - ROOMS 201/202 2
CK
T Circuit Description Trip Poles A B C Poles Trip Circuit Description
CK
T
Notes:
Enclosure: NEMA 1 MCB Rating: 125 A
Mounting: SURFACE Wires: 4 Mains Rating: 125 A
Supply From: 03 Phases: 3 Mains Type: MCB
Location: EQUIPMENT 218 Volts: 120/208V A.I.C. Rating: 18KAIC
Branch Panel: PP-231-02-006
Legend:
Total Amps: 91 A 91 A 91 A
Total Load: 25,353 VA 25,353 VA 25,353 VA
41 42
39 40
37 38
35 36
33 34
31 32
29 30
27 28
25 26
23 5,833 VA 24
21 5,833 VA 22
AHU-2 20 A 3
5,833 VA 20
17 5,820 VA 5,833 VA 18
15 5,820 VA 5,833 VA 16
CHP-01-02 30 A 3
5,820 VA 5,833 VA
3 20 A AHU-1
11 1,233 VA 5,820 VA 12
9 1,233 VA 5,820 VA 10
HEAT TRANSFER PACKAGE HTP-1 20 A 3
1,233 VA 5,820 VA
3 30 A CHP-01-01
5 407 VA 407 VA 6
3 407 VA 407 VA 4
EF #1 20 A 3
407 VA 407 VA
3 20 A EF #2
CK
T Circuit Description Trip Poles
A B C A B C
Poles Trip Circuit Description
CK
T
EXISTING MOTOR CONTROL CENTER. NEW WORK IS INDICATED IN BOLD.
Notes:
Enclosure: NEMA 1 MCB Rating: 175 A
Mounting: FLOOR Wires: 3 Mains Rating: 200 A
Supply From: PANEL SW-A Phases: 3 Mains Type: MCB
Location: MECH ROOM NO. 1 038 Volts: 480V A.I.C. Rating: 22
Branch Panel: MCC
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
W
W
W
W
W
W
W
W
W
W
A V
A V
W
J.E
3.E 2.E 1.E4.E5.E6.E7.E8.E9.E
F.E
E.E
A.E
MECHANICAL
ROOM
ELECTRIC
COMM
BREAK/LUNCH
NEW BUSINESS
WOMEN'S RR
MEN'S RR
STOR
ACCESSIBLE RR
ELEVATOR
HALLWAY
PROGRAM MGMT
MECHANICAL
ROOM
STAIR B
OFFICE
OFFICE
OFFICE
HALLWAY
OFFICE
OFFICE
OFFICE
OFFICE
MEETING
ENGINEERING
CHIEF
BRANCH OFFICE
DIRECTOR
MEETING
OFFICE
OFFICE
OFFICE
OFFICE
STAIR C
041 CONFERENCE
ROOM
BREAK/LUNCH
OFFICE
OFFICE
OFFICE
STAIR A
STORAGE
PROGRAM MGMT
T-401
D10
T-401
D2
EQUIPMENT
218 T-402
F3
T-402
F12
H2
T-202
MGB-231-02-001
JANITOR
7 10
H2
T-504
H2
T-202
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
PLAN NORTH
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:3
A
M
T-121
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N P
L A
N
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
T L O
V V
O R
N
J W
IT
H
R O
W
W H
O W
E N
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
1/8" = 1'-0"B1
SECOND FLOOR TELECOM PLAN
8'4' 16'0
GENERAL SHEET NOTES:
1. ALL PENETRATIONS THROUGH WALLS AND SLABS SHALL BE SEALED AIR TIGHT
(WITH ACOUSTIC / FIRE SEALANT). SEAL CONDUIT STUBS, PIPING STUBS, DUCT
PENETRATIONS, ELECTRICAL JUNCTION BOX OPENINGS, CONTROL WIRING
OPENINGS, GYPSUM BOARD OPENINGS, CONCRETE OPENING, AND PIPING
PENETRATIONS. CAP ALL OPEN CONDUITS.
2. COORDINATE WITH MECHANICAL CONTRACTOR TO ENSURE THAT
TELECOMMUNICATIONS EQUIPMENT DOES NOT BLOCK MAINTENANCE ACCESS
FOR WATER-TO-AIR HEAT PUMPS (WAHP). LOCATION AND MAINTENANCE
CLEARANCE OF WAHPS ARE SHOWN IN MECHANICAL MH SERIES DRAWINGS.
3. COMMUNICATION DROP FACEPLATE TERMINATIONS ARE SHOWN ON T-502.
COORDINATE EXACT SURFACE MOUNT OR WALL/FLOOR OUTLET BOX WITH
BASE COMM.
SHEET KEYNOTES:
1. 2" H X 12" W NIPR BASKET TRAY.
2. 4" H X 5" W SIPR SURFACE MOUNT RACEWAY.
3. POWER FOR FLOOR BOX MUST BE ROUTED IN SEPARATE CONDUIT FROM DATA
CABLES FOR SECURE OUTLETS.
4. CONDUIT, 2", STUBBED 2"-3" BELOW FINISHED CEILING, CONDUIT EXTENDS TO
UNCLASSIFIED CABLE TRAY FOR ROUTING 12 SMF.
5. SURFACE MOUNT CABLE TRAY FOR AV AND DATA CABLES.
6. SURFACE MOUNT CABLE TRAY FOR SECURE DATA DROPS WITHIN THE OPEN
STORAGE AREAS. TRAY SHALL BE MOUNTED AROUND THE WALL AGAINST THE
CEILING WITH VERTICAL RUNS TO CUBICLES.
7. ALL 12 SMF SHALL HAVE A 10 FT MAINTAINANCE LOOP LOCATED IN CABLE
TRAY. CARE MUST BE TAKEN TO ENSURE THE BEND RADIUS IS NOT EXCEEDED.
8. SURFACE MOUNT RACEWAY SHALL BE SIZED TO ACCOMMODATE
MANUFACTURER BEND RADIUS SPECIFICATIONS OF COMMUNICATIONS CABLE
SUPPORTED.
9. ALL EXTERIOR CUBICLE DATA DROPS SHALL BE SURFACE MOUNTED TO WALL
OUTLETS. ALL INTERIOR CUBICLE DATA DROPS SHALL BE ROUTED TO THE
DATA OUTLET LOCATION AND HAVE AN ADDITIONAL 30 FT OF CABLE COILED
UP. THIS WILL ALLOW THE FURNITURE INSTALLERS TO RUN THE CABLE TO
FURNITURE MOUNTED OUTLETS. THE FURNITURE IS NOT PART OF THIS
PROJECT AND WILL BE COMPLETED AFTER THIS PROJECT IS FINISHED.
10. PROVIDE THIS DATA OUTLET IN THE DDC CONTROL PANEL. FIELD COORDINATE
THE LOCATION WITH THE MECHANICAL ROOM.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
SECOND FLOOR
115'-5 1/2"
VERTICAL LADDER TRAY ON WALL,
12"W FROM TELECOM ENCLOSURE
TO FINISHED CEILING
TELECOM ENCLOSURE, 12RU, 23"D, LOCKABLE
FIBER OPTIC PATCH PANEL, 1RU, 12 SC
CABLE MANAGEMENT PANEL, 1RU
FIBER OPTIC PATCH PANEL, 4RU, SC (OM3 MMF)
CABLE MANAGEMENT PANEL, 1RU
END USER EQUIPMENT
FPP-01
CMP-01
FPP-02
CMP-02
A
F F
3 SIPRNET SURFACE
MOUNTED RACEWAY
SIPRNET SURFACE
MOUNTED RACEWAY
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:1
A
M
T-202
T E
L E
C O
M E
L E
V A
T
IO
N S
S
IP
R
N E
T
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
T L O
V V
O R
N
J W
IT
H
R O
W
W H
O W
E N
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
1/2" = 1'-0"H2
SIPRNET TELECOMMUNICATIONS
ENCLOSURE IN OPEN STORAGE WORK
AREA
2'1' 4'0
SHEET KEYNOTES:
1. FIELD COORDINATE INSTALLATION OF TELECOMMUNICATIONS EQUIPMENT
BONDING CONDUCTOR TO TELECOMMUNICATIONS ENCLOSURE FROM
PRIMARY BONDING BUSBAR.
2. WALL MOUNTED TELECOMMUNICATION ENCLOSURE.
3. CONDUIT, 2", STUBBED 2"-3" BELOW FINISHED CEILING, CONDUIT EXTENDS TO
UNCLASSIFIED CABLE TRAY FOR ROUTING 12 SMF, APPLY SEALANT TO THE
ANNULAR SPACE BETWEEN CONDUIT AND FINISHED CEILING TO KEEP THE STC
RATING.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
FINISHED CEILING
MOUNT IN-WORK AT SAME
HEIGHT AS ADJACENT WORK
BOXES WITHIN ROOM
CONDUITS STUBBED ABOVE
ACCESSIBLE CEILING SPACE
WHERE INDICATED
FINISHED FLOOR
CONTRACTOR INSTALLED
2 GANG OUTLET BOX;
STUB CONDUIT BELOW
RAISED ACCESS FLOOR
J JJJ JJJ J
BASKET TRAY
2" GROMMET
FINISHED CEILING
SURFACE MOUNT OUTLET BOX
CONDUIT
FINISHED FLOOR
UNLESS SUPPORTING SYSTEMS FURNITURE, ALL NETWORK OUTLETS
SUPPORTING USASOC SHALL BE MOUNTED 72" ABOVE FLOOR LEVEL AND A
MINIMUM OF 6" FROM ANY OUTLET BOX OF A DIFFERENT CLASSIFICATION.
FURTHER CONSIDERATION SHOULD BE TAKEN IN THE SELECTION OF ANY
FURTHER CONSIDERATION SHOULD BE TAKEN IN THE SELECTION OF ANY
FURNITURE OR PARTITIONS THAT WILL BE HOSTING BOTH UNCLASSIFIED
AND CLASSIFIED CABLE RUNS /OUTLET BOX MOUNTING LOCATIONS SO AS
TO ENSURE THE PROPER SEPARATION IAW CNSSAM TEMPEST/1-13.
SIPRNET SURFACE
MOUNTED RACEWAY
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:0
A
M
T-503
T E
L E
C O
M D
E T
A
IL
S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
T L O
V V
O R
N
J W
IT
H
R O
W
W H
O W
E N
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
NTSH1
INSTALLATION OF TYPICAL WORK AREA
OUTLET LOCATIONS DETAIL
NTSA1
AV WALL BOX DETAIL (2-GANG)
NTSH10
INSTALLATION OF TYPICAL SECURE AREA
SURFACE MOUNT OUTLET LOCATIONS
DETAIL
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
CEILING
SIPR LOCKING
OUTLET BOX
ELECTRICAL
BOX AND PLATE
TYPICAL METAL STUD
FLAT PANEL
MOUNT FRAME
WOOD BLOCKING
(FP2) BACK BOX
AV CONDUIT
PER RISER DIAGRAM
80" FLAT PANEL
ON MOUNT
AV POWER CONDUIT
FLOOR
3/4" PLYWOOD BLOCKING
46" x 24"
CEILING
FLOOR
16"
6"
SURFACE MOUNT CABLE TRAY
FOR AV AND DATA CABLES
2 2 GANG SURFACE
MOUNT BOX
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:3
A
M
T-504
T E
L E
C O
M D
E T
A
IL
S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
T L O
V V
O R
N
J W
IT
H
R O
W
W H
O W
E N
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
NTSH2
CONFERENCE ROOM SIDE WALL FLAT
PANEL DETAIL (TYPICAL FOR EACH FLAT
PANEL)
GENERAL SHEET NOTES:
1. METAL STUDS ARE TYPICAL 16" O.C OR 24" O.C.
2. EXACT SIZE OF BLOCKING MAY VARY PENDING POSITION OF METAL STUDS OR
FIELD CONDITIONS OF WALL.
3. WOOD BLOCKING TO BE FIRE RATED.
SHEET KEYNOTES:
1. EXACT MONITOR SIZE AND POSITION ON WALL TO BE FIELD COORDINATED
WITH CONTRACTOR.
2. FIELD COORDINATE AV WALL BOX LOCATION.
3. SURFACE MOUNT RACEWAY SHALL BE SIZED TO ACCOMMODATE
MANUFACTURER BEND RADIUS SPECIFICATIONS OF COMMUNICATIONS CABLE
SUPPORTED
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
SECURITY
BALANCED MAGNETIC SWITCH
DEVICE INTERFACE BOX
ELECTRIFIED MORTISE LOCK
CARD READER OPTIONS:
• 1 - LEVEL 1 CARD READER
• 2 - LEVEL 2 CARD READER W/INTEGRAL
KEYPAD OR SEPARATE KEYPAD
• 3 - LEVEL 3 CARD READER W/KEYPAD
AND BIOMETRICS
• X - SHALL BE REPLACED BY NUMBERS
LISTED ABOVE AS INDICATED ON PLAN
DRAWING
BATTERY
DUAL READER INTERFACE
FIBER OPTIC PATCH PANEL
POWER DISTRIBUTION MODULE
POWER SUPPLY
NETWORK SWITCH
BAR REQUEST TO EXIT
X
INPUT CONTROL MODULE
SURGE SUPPRESSION DATA
SURGE SUPPRESSION POWER
CAMERA JUNCTION BOX
INTELLIGENT SYSTEM CONTROLLER
CJB
ML
BATT
BREX
DRI
FOP
ICM
ISC
NSW
PDM
PS
SSDA
SSP
DIB (COMMUNICATION)
CAMERA JUNCTION BOX
CARD READER
BALANCED MAGNETIC SWITCH
ELECTRIFIED MORTISE LOCK
TAMPER SWITCH
BREX / REX
CAMERA (DATA)
EXTERIOR CAMERA (HEATING)
READER INTERFACE TO CONTROL MODULE /
READER INTERFACE, INPUT CONTROL
MODULE
BASE STANDARD FIBER OPTIC CABLE
CATEGORY 6 DATA CABLE *
300V, #20 AWG, 8 C, SH, PVC
300V, #20 AWG, 1 PR, SH, PVC
300V, #16 AWG, 1 PR, PVC
300V, #18 AWG, 1 PR, SH, PVC
300V, #16 AWG, 1 PR, PVC
CATEGORY 6 DATA CABLE *
300V, #14 AWG, 1 PR, PVC *
300V, #18 AWG, 2 PR, SH, PVC
TO CABLE TYPE
SECURITY CABLE TYPES
REX REQUEST TO EXIT
DIB
JB JUNCTION BOX
SRI SINGLE READER INTERFACE
T TAMPER SWITCH
ABBREVIATIONS
ACS
AWG
BATT
BMS
BREX
C
CCTV
CJB
CR
DIB
DRI
FDB
FOP
IDS
ISC
JBOX
KP
ML
MOT
NSW
NTS
POE
PR
PVC
REQ'D
REX
SH
SRI
T
V
ACCESS CONTROL SYSTEM
AMERICAN WIRE GAUGE
BATTERY
BALANCED MAGNETIC SWITCH
BAR REQUEST TO EXIT
CONDUCTOR
CLOSED CIRCUIT TELEVISION
CAMERA JUNCTION BOX
CARD READER
DEVICE INTERFACE BOX
DUAL READER INTERFACE
FIELD DISTRIBUTION BOX
FIBER OPTIC PATCH PANEL
INTRUSION DETECTION SYSTEM
INTELLIGENT SYSTEM CONTROLLER
JUNCTION BOX
ARM / DISARM KEYPAD
ELECTRIFIED MORTISE LOCK
MOTION SENSOR
NETWORK SWITCH
NOT TO SCALE
POWER OVER ETHERNET
PAIR
POLYVINYL CHLORIDE
REQUIRED
REQUEST TO EXIT
SHIELDED
SINGLE READER INTERFACE
TAMPER SWITCH
VOLT
FDB FIELD DISTRIBUTION BOX
* COORDINATE WITH CONTRACTING OFFICER
ARM / DISARM KEYPAD
360 DEG MOTION DETECTOR
KP
MOTION DETECTOR, KEYPAD 300V, #18 AWG, 2 PR, SH, PVC
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
J B
A T
E S
C A
T E
G O
R Y
C O
D E
CUI / CONTROLLED UNCLASSIFIED INFORMATION
CUI / CONTROLLED UNCLASSIFIED INFORMATION
C
R e v it \l o c a l_
\R
A F
B -B
L D
G -E
W it h ro w jt .r v t
/2
/2
:3
:1
P
M
TY001
S E
C U
R
IT
Y L
E G
E N
D
N O
T E
S
R O
B
IN
S A
IR
F
O R
C E
B A
S E
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
O
G L E
T H
O R
P E
A V
E
S A
V A
N N
A H
G
A
B L A
C K
A N
D V
E A
T C
H S
P E
C
IA
L P
R O
J E
C T
S C
O R
P
W
T
H S
T R
E E
T S
U
IT
E
O V
E R
L A
N D
P A
R K
K
A N
S A
S
-2
J T
D N
E L S
O N
J W
IT
H
R O
W
N W
H E
A T
L E
Y
D E
C E
M B
E R
W H
N -2
-R
-4
R E
A D
Y T
O A
D V
E R
T
IS
E
R T
A
B L D
G
S
E C
O N
D -F
L O
O R
A D
D
IT
IO
N
F Y
P
N U
H H
Z -3
-8
-0
GENERAL NOTES:
1. ACCESS CONTROL SYSTEM AND INTRUSION DETECTION SYSTEMS ARE CFCI
AND WILL BE FIELD-ROUTED FROM THE SECOND FLOOR INTO THE EXISTING ACS
NETWORK SWITCH(ES) IN ROOM 127.
2. THE BASE HAS SEPARATE INTRUSION DETECTION AND ACCESS CONTROL
SYSTEMS. ALL IDS AND ACS EQUIPMENT IS CFCI. COORDINATE INSTALLATION OF
BOTH SYSTEMS WITH THE CONTRACTING OFFICER.
3. THIS DESIGN ONLY INCLUDES REQUIRED INFRASTRUCTURE FOR CCTV; ALL
CAMERAS, CCTV CABLES, AND MONITORING SYSTEM(S) ARE GFGI. ANY CCTV
EQUIPMENT RELOCATED DUE TO THE SECOND-FLOOR ADDITION WILL BE
ROUTED THROUGH THE FDB ON THE SECOND FLOOR AND CONNECTED TO THE
EXISTING CCTV SYSTEM ON THE FIRST FLOOR. THE CONTRACTOR SHALL
COORDINATE WITH THE CONTRACTING OFFICER/GOVERNMENT FOR THE EXACT
CCTV CAMERAS TO BE RELOCATED. THE CONTRACTOR WILL THEN FIELD-ROUTE
CCTV INFRASTRUCTURE AS NEEDED THROUGH THE FDB INTO THE EXISTING
CCTV NETWORK SWITCH(ES) IN ROOM 127. THE GOVERNMENT WILL SUPPLY
AND INSTALL ALL CCTV CAMERAS AND RELATED CABLES.
4. THE CONTRACTOR SHALL COORDINATE WITH THE END USER AND AN ACS/IDS
VENDOR AND DETERMINE WHICH FIRST FLOOR EQUIPMENT WOULD NEED TO BE
UPDATED/REPLACED IN ORDER TO ACCOMMODATE THE NEW ACS/IDS
EQUIPMENT FOR THE 2ND FLOOR. CONTRACTORS SHOULD DETERMINE THE
BEST METHOD TO ACCOMPLISH THE WORK AS SHOW IN THE PLANS,
SPECIFICATIONS AND DRAWINGS. BID/PROPOSE AS SHOWN IN THE PLANS AND
SPECIFICATIONS.
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
F
E B
| A-200 BUILDING ELEVATIONS |
| A-500 PARTITION TYPES & DETAILS |
| A-505 WALL SECTION DETAILS |
| E-121 SECOND FLOOR POWER AND GROUNDING PLAN |
| E-201 OUTDOOR ELECTRICAL SECTIONS |
| E-401 ELECTRICAL ROOM ENLARGED PLAN |
| E-702 POWER PANEL SCHEDULE |
| T-121 SECOND FLOOR TELECOMMUNICATION PLAN |
| T-202 TELECOM ELEVATIONS - SIPRNET |
| T-503 TELECOM DETAILS |
| T-504 TELECOM DETAILS |
| TY001 SECURITY LEGEND & NOTES |