W912HN-21-B-3005_DRAWINGS_VOL2_AMD1.pdf
PDF 531 KB Posted
- Solicitation number
- W912HN21B3005
About this file
This is an invitation for bid for repair and renovation work on Barracks Building 315 at Fort Gordon, Georgia. The project scope includes replacement of failing HVAC systems and components, repair of moisture and mildew damage, replacement of exterior and interior components and finishes, upgrade of latrines, lighting, and fire alarm and mass notification systems. Work will involve demolition, abatement of hazardous materials, and installation of new systems and components to comply with accessibility standards and increase quality of life for soldiers. The contract is set aside for small businesses under NAICS code 236220 with an estimated value between $10-25 million. Responses are due in accordance with FAR Part 14 procedures. The point of contact listed is Mr. Lennie K. Mattis of the Army Corps of Engineers Savannah District.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTES:
1. WHERE THREE BARS OCCUR, CENTER BAR SHALL BE HAVE 90 DEGREE STANDARD HOOK.
TYPICAL FOOTING
REINFORCING, (TYP)
PLAN AT
CORNER
PLAN AT
INTERSECTION
BARS, (TYP)
0" BETWEEN
3' - 0"
3'
0"
'L' BAR TO MATCH
HORIZONTAL
REINFORCING
BA
R
S, (T
YP
0" B
ET
W
EE
N
TYPICAL FOOTING
REINFORCING, (TYP)
1'
6"
HOOKED SPLICE BAR
TO MATCH
HORIZONTAL FOOTING
OR WALL
REINFORCING
BARS, (TYP)
0" BETWEEN
1' - 6" 1' - 6"1' - 6"
WALL CORNER
OPENING - WALL TERMINATION
VERTICAL WALL
REINFORCING
WALL INTERSECTION
VERTICAL WALL
REINFORCING
NOTES:
1. INTERMEDIATE HORIZONTAL BOND BEAM REINFORCING SHALL TERMINATE AT CMU CONTROL
JOINTS. REINFORCING FOR BOND BEAMS AT TOP OF WALLS SHALL BE CONTINUOUS.
2. HORIZONTAL BARS SHALL BE ANCHORED AROUND VERTICAL BARS WITH A STANDARD HOOK.
VERTICAL WALL
REINFORCING
EQ EQ
EQ
EQ
EQ
EQ
EQ EQ
SEE PLAN
WALL
OPENING
EQ EQ
HORIZONTAL BOND BEAM
REINFORCING
HORIZONTAL BOND BEAM
REINFORCING
HORIZONTAL BOND
BEAM
REINFORCING
WALL CONTROL JOINT
(1) FULL HEIGHT VERTICAL BAR IN
GROUT FILLED CELLS ON EACH SIDE OF
JOINT TO MATCH WALL REINFORCING
CONTROL JOINT WITH FULL HEIGHT
BACKER ROD AND SEALANT - REFER TO
ARCHITECTURAL DWGS FOR DETAILS
NOTES:
1. CONTROL JOINT SPACING SHALL NOT EXCEED 2X WALL HEIGHT OR 20'-0" MAX.
2. CONTROL JOINTS SHALL EXTEND FULL HEIGHT OF CMU WALL.
3. BOND BEAM REINFORCING AT OR NEAREST ROOF OR FLOOR ABOVE SLABS ON GRADE
SHALL BE CONTINUOUS THROUGH CONTROL JOINTS.
4. JOINT REINFORCEMENT SHALL BE DISCONTINUOUS AT CONTROL JOINTS UNLESS NOTED
OTHERWISE ON PLANS AND DETAILS.
5. BACKER ROD MAY BE OMITTED IF FULL WIDTH PREMOLDED CONTROL JOINT KEY IS
EMPLOYED. COORDINATE JOINT DETAILS WITH ARCHITECTURAL REQUIREMENTS.
EQ
EQ
CMU WALL
PREMOLDED CONTROL
JOINT KEY
3/8" JOINT
DISCONTINUOUS BOND
BEAM REINFORCEMENT,
(TYP)
8" MIN DEEP CONCRETE TIE BEAM
W/ (2) #4 AT TOP OF SLOPED WALLS,
STEP BLOCKS BELOW AS REQD
8" CMU WALL, SEE PLAN AND
SCHEDULE FOR REINFORCING
T/ WALL
VERTICAL DOWEL TO MATCH WALL
REINFORCING SIZE AND SPACING,
LAP SPLICE PER SCHEDULE
CONCRETE FOOTING -
SEE PLAN AND SCHEDULE
FOR SIZE AND REINFORCING
1/2" PREMOLDED JOINT FILLER
CONCRETE SLAB ON GRADE, SEE PLAN
0" SPCG
FURRING STUDS,
SEE ARCH
METAL PANELS,
SEE ARCH
SEE PLAN
5/8" DIA HD SCREW ANCHOR
W/ 4 3/4" MIN EMBED @ 16" OC
L4X4X1/4 DECK CLOSURE ANGLE
24" DEEP CMU BOND BEAM AT MECHANICAL
PLATFORM FLOOR REINFORCED
W/ (2) #4 CONT TOP AND BOTTOM IN GROUT
FILLED CELLS
8" CMU BOND BEAM AT BASE OF
WALL REINFORCED WITH (2) #4
CONT IN GROUT FILLED CELLS
METAL DECK, SEE PLAN
2-1/2" DEEP JOIST SUBSTITUTE,
SEE PLAN
JOIST, SEE PLAN
DECK EDGE PLATES,
SEE SF507
T/ FTG
(-) 1'-4"
BOND BEAM AT TOP OF WALL AND AT ROOF
BEARING LEVEL - SEE PLAN AND DETAILS
FOR LOCATIONS AND REINFORCING
PLACE METAL LATH OR WIRE SCREEN
OVER CORES NOT TO BE FILLED
(SHEET METAL AND FELT PROHIBITED)
VERTICAL REINFORCING WITH MATCHING
DOWELS INTO FOUNDATION. SEE PLAN
FOR SIZE AND LOCATION. PROVIDE BAR
POSITIONERS PER PROJECT
SPECIFICATIONS SECTION 04 20 00.
HORIZONTAL JOINT REINFORCING @ 16"
OC STARTING AT FIRST COURSE ABOVE
FOUNDATION. LAP SPLICES 8". USE
PREFABRICATED L'S AND T'S AT WALL
INTERSECTIONS.
GROUT FILLED CELL AT REINFORCING
LOCATIONS - PLACE AND CONSOLIDATE
GROUT IN 5 FOOT LIFTS (MAX)
MORTAR CROSS WEBS ADJACENT TO
FILLED CELLS
ASTM C90 CMU UNITS IN RUNNING BOND
FOUNDATION OR THICKENED SLAB
SET FIRST COURSE IN
FULL MORTAR BEDDING
PROVIDE CLEAN OUT
OPENINGS AT GROUT
FILLED CELL LOCATIONS
16" MAX 16" MIN 16" MAX
(2)#4 HORIZ
GROUTED SOLID
EXTEND 24"
BEYOND EDGE
OF OPENING
GROUT
OPENING
AFTER
INSTALLING
CONDUIT
A
A A-A
STEEL COLUMN,
SEE PLAN
T/FTG
(-) 1'-4"
EXISTING WALL FOOTING
EXISTING FOUNDATION WALL
EXISTING EXTERIOR WALL
EXISTING FLOOR SLAB
T/EXISTING
(-) 4'-8"2" THICK X 2'-0" WIDE VOID FORM
4" CAPILLARY BARRIER
10 MIL VAPOR RETARDER
COMPACTED SUBGRADE
1/2" PREMOLDED JOINT FILLER
1' - 2"
EOC
1' - 1 1/2"
1' - 0"
SF501
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENXCTA\Documents\FY21_PN95039_BLDG315_STRUCT_R21_K6ENXCTA.rvt
7/20/2021 9:50:02 AM
JU
LY
W
2H N
-2 1-
B-
C . A
TK
IN
S
C . A
TK
IN
S
S.
B
AR
BI
N A
1-
-1
SF505
FR
AM
IN
G
D
ET
AI
LS
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
J.
W
H
IT
TA
KE
R
READY TO ADVERTISE (RTA)
TYPICAL CONT. FTG REINFORCING DETAIL2 TYPICAL CMU WALL REINFORCING DETAIL3
TYPICAL CMU WALL CONTROL JOINT DETAIL4
MECHANICAL ADDITION MASONRY WALL SECTION6
TYPICAL MASONRY CONSTRUCTION DETAIL1
CONDUIT OPENING THROUGH CMU FDN WALLS5 MECHANICAL ADDITION ABUTTING EXISTING7
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
058'
0"
SOLID SURFACE
PANELS
SCSCR
TR
GB
8'
0"
SOLID SURFACE PANELS
SCSCR
MG MC
TR
TP
GB
8'
0"
A-523
Sim
SOLID SURFACE PANELS
SCSCR
SH
8'
0"
5'
15 INCHES DEEP
CLOSET SHELF &
ROD
7'
0"
5'
15 INCHES DEEP
CLOSET SHELF &
ROD
7'
0"
5'
15 INCHES DEEP
CLOSET SHELF &
ROD
7'
0"
5'
15 INCHES DEEP
CLOSET SHELF &
ROD
7'
0"
2'
6" 1'
2"
4" 3'
0"
7'
0"
028'
0"
1'
0"
018'
0"
7'
0" 1'
0"
8'
0"
2'
6" 1'
2"
4" 3'
0"
7'
0"
2' - 0" 2' - 0" 2' - 6" 2' - 0"
8'
0"
GFGI
GFGI
UL 507
RANGE HOOD
A-523
A-523
A-523
GFGI GFGI
3'
0" 4"
1'
2" 2'
6"
7'
0"8'
0"
7'
0" 1'
0"
A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN CENTERLINES,
UNLESS NOTED OTHERWISE (U.N.O.).
B. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.
C. REFERENCE SHEETS A-601 & A-602 FOR PARTITION TYPES.
D. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR TYPICAL
TILE SIZE AND PATTERNS.
E. SLOPE SLABS TO FLOOR DRAINS, TYP.
F. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL TOILET
ACCESSORIES.
G. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL WALL HUNG
FIXTURES (LAVATORIES, URINALS, ETC.).
H. SHOWER ENCLOSURE SHALL BE FULL HEIGHT SOLID SURFACE AS INDICATED.
ALL OTHER AREAS SHALL HAVE FULL HEIGHT CERAMIC WALL TILE AS INDICATED.
I. REFERENCE SHEETS A-011, A-012, & A-013 FOR FIXTURE MOUNTING HEIGHTS.
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt
7/20/2021 4:35:29 PM
JU
LY
W
2H N
-2 1-
B-
R .R
U
PP
E
R .R
U
PP
E
S.
B
AR
BI
N A
1-
-1
A-403
EN
LA
R G
ED
IN
TE
R
IO
R
E
LE
VA
TI
O N
LI
VI
N
G U
N
IT
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
P.
S
U
LL
IV
AN
READY TO ADVERTISE (RTA)
1/4" = 1'-0"
BATHROOM1
1/4" = 1'-0"
BATHROOM2
1/4" = 1'-0"
BATHROOM3
1/4" = 1'-0"
BATHROOM4
4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 82
4 3 1 0 4 82
1/4" = 1'-0"
CLOSET5
1/4" = 1'-0"
CLOSET6
1/4" = 1'-0"
CLOSET7
1/4" = 1'-0"
CLOSET8
1/4" = 1'-0"
KITCHEN9
1/4" = 1'-0"
KITCHEN10
1/4" = 1'-0"
KITCHEN11
1/4" = 1'-0"
KITCHEN12
4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 824 3 1 0 4 82
MG
MC
TR
TP
ACCESSORY SCHEDULE
ACCESSORY DESCRIPTION TYPE MARK
GRAB BAR - VERTICAL GB
HOOK, GARMENT HK
MEDICINE CABINET MC
24"x36" MIRROR MG
SURFACE MOUNTED MOP/BROOM HOLDER MR
PAPER TOWEL DISPENSER/WASTE RECEPTACLE PDTWR
SHOWER CURTAIN & ROD SCSCR
WALL MOUNTED SOAP DISPENSER SD
SOAP HOLDER SH
SANITARY NAPKIN DISPOSER SND
SURFACE MOUNTED MULTI-ROLL TOILET TISSUE
DISPENSER
TP
24" TOWEL BAR TR
TOILET SEAT COVER DISPENSER - SURFACE TSCD
GENERAL SHEET NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
8'
0"
103 102 8'
0"
4'
6"
C1B
GFCIGFCIGFCIGFCI 5'
1/
2" M
IN
2'
4"
1' - 3"
PLUMBING
ACCESS
PANEL
8'
0"
1'
3"
101 1048'
0"
1058'
0"
8'
0"
A
4'
6"
3'
0"
AA
8'
0"
8'
0"
8'
0"
6'
0"
MR
2'
0"
1038'
0"
6'
0" 2'
0" MR
8'
0"
6'
0" 2'
0"
MR
GB1
GB2
MG
8'
0"
TP
SND
SD
GB1
GB28'
0"
TSCD
TP
SND
PTDWR
TSCD
TP
HK
4'
0"
MG
PTDWR
HK
A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN CENTERLINES,
UNLESS NOTED OTHERWISE (U.N.O.).
B. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.
C. REFERENCE SHEETS A-601 & A-602 FOR PARTITION TYPES.
D. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR TYPICAL
TILE SIZE AND PATTERNS.
E. SLOPE SLABS TO FLOOR DRAINS, TYP.
F. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL TOILET
ACCESSORIES.
G. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL WALL HUNG
FIXTURES (LAVATORIES, URINALS, ETC.).
H. SHOWER ENCLOSURE SHALL BE FULL HEIGHT SOLID SURFACE AS INDICATED.
ALL OTHER AREAS SHALL HAVE FULL HEIGHT CERAMIC WALL TILE AS INDICATED.
I. REFERENCE SHEETS A-011, A-012, & A-013 FOR FIXTURE MOUNTING HEIGHTS.
2'
4' - 0" 2' - 6" 1' - 9"
8' - 3"
A-523
8'
0"
3' - 0" 3' - 0"
6' - 0" 2'
A-523
8'
0"
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt
7/20/2021 4:36:03 PM
JU
LY
W
2H N
-2 1-
B-
R .R
U
PP
E
R .R
U
PP
E
S.
B
AR
BI
N A
1-
-1
A-404
EN
LA
R G
ED
IN
TE
R
IO
R
E
LE
VA
TI
O N
S -S
ER
VI
C E
M O
D U
LE
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
P.
S
U
LL
IV
AN
READY TO ADVERTISE (RTA)
1/4" = 1'-0"
LOBBY1
1/4" = 1'-0"
LOBBY2
1/4" = 1'-0"
LOBBY3
1/4" = 1'-0"
LOBBY4
1/4" = 1'-0"
ACTIVITY ROOM5
1/4" = 1'-0"
ACTIVITY ROOM6
1/4" = 1'-0"
ACTIVITY ROOM7
1/4" = 1'-0"
ACTIVITY ROOM9
1/4" = 1'-0"
JANITOR10
1/4" = 1'-0"
JANITOR11
1/4" = 1'-0"
JANITOR13
1/4" = 1'-0"
RESTROOM14
1/4" = 1'-0"
RESTROOM15
1/4" = 1'-0"
RESTROOM16
1/4" = 1'-0"
RESTROOM17
GENERAL SHEET NOTES
4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 824 3 1 0 4 824 3 1 0 4 82
4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 82
4 3 1 0 4 82
4 3 1 0 4 824 3 1 0 4 82
4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82
4 3 1 0 4 82
ACCESSORY SCHEDULE
ACCESSORY DESCRIPTION TYPE MARK
GRAB BAR - VERTICAL GB
HOOK, GARMENT HK
MEDICINE CABINET MC
24"x36" MIRROR MG
SURFACE MOUNTED MOP/BROOM HOLDER MR
PAPER TOWEL DISPENSER/WASTE RECEPTACLE PDTWR
SHOWER CURTAIN & ROD SCSCR
WALL MOUNTED SOAP DISPENSER SD
SOAP HOLDER SH
SANITARY NAPKIN DISPOSER SND
SURFACE MOUNTED MULTI-ROLL TOILET TISSUE
DISPENSER
TP
24" TOWEL BAR TR
TOILET SEAT COVER DISPENSER - SURFACE TSCD
1/4" = 1'-0"
ACTIVITY ROOM8
1/4" = 1'-0"
ACTIVITY ROOM12
4 3 1 0 4 82
36" GRAB BAR
48" GRAB BAR
GB1
GB2
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
EXTERIOR/INTERIOR
SINGLE DOORS
IN MASONRY WALL
4"
AS
S
C H
ED
4"
AS
S
C H
ED
2" AS SCHED 2" 2" AS SCHED 2"
INTERIOR
SINGLE DOORS
EXTERIOR
DOUBLE DOORS
IN MASONRY WALL
EXTERIOR
UNEVEN DOOR
IN MASONRY WALL W/ STEEL
PANEL TRANSOM
6'
8"
2"
2" AS SCHED 2"
8'
0"
7'
0"
2" 2"AS SCHED
4"
6"STEEL PANEL
EXTERIOR SINGLE DOOR
IN MASONRY WALL W/ STEEL
PANEL TRANSOM
8'
0"
7'
0"
2" 2"AS SCHED
4"
6"STL PANEL
TYPE F TYPE R
2'
0" 6"
4"
6"
TYPE DF TYPE UF
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt
7/20/2021 4:41:13 PM
JU
LY
W
2H N
-2 1-
B-
R .R
U
PP
E
R .R
U
PP
E
S.
B
AR
BI
N A
1-
-1
A-603
D O
O R
S C
H
ED
U
LE
A N
D T
YP
ES
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
P.
S
U
LL
IV
AN
READY TO ADVERTISE (RTA)
USACE_DOOR SCHEDULE
DOOR
NUMBERS TYPE
DOOR
FIRE
RATING
FRAME
HARDWARE COMMENTS:
SIZE
MATERIAL FINISH TYPE MATERIAL FINISH
DETAIL
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
01 F 3' - 0" 6' - 8" 1 3/4" WOOD STAIN 1⁄3-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 7 UNIT ENTRY 02 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 8 UNIT BEDROOM 03 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 10 UNIT CLOSET 04 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 9 UNIT BATHROOM 05 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 9 UNIT BATHROOM 06 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 8 UNIT BEDROOM 07 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 10 UNIT CLOSET 08 F 2' - 6" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 UNIT MECH
101 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 3/A-605 6/A-605 9/A-605 2 LOBBY 102 R 3' - 0" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 11 ACCESSIBLE RESTROOM 103 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 5 JANITORS 104 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 1/A-605 4/A-605 7/A-605 5 STORAGE 105 R 3' - 0" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 1/A-605 4/A-605 7/A-605 12 ACTIVITY 107 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ & RISER RM 108 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 FA CP 109 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 110 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 TELE COMM 111 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 112 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 113 DF 6' - 0" 7' - 0" 1 3/4" HM PAINT N/A 3 HM PAINT 2/A-604 5/A-604 8/A-604 3 MECH RM 114 F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 5 HM PAINT 1/A-604 4/A-604 7/A-604 4 MECH EQ RM 115 UF 5' - 0" 7' - 0" 1 3/4" HM PAINT N/A 4 HM PAINT 1/A-604 4/A-604 7/A-604 3 ELECTRICAL RM 116 DF 5' - 0" 6' - 8" 1 3/4" HM PAINT N/A 3 HM PAINT 1/A-604 4/A-604 7/A-604 3 MECH EQ RM 117 DF 6' - 0" 7' - 0" 1 3/4" HM PAINT N/A 3 HM PAINT 2/A-604 5/A-604 8/A-604 3 MECH RM 201 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 202 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 STORAGE 203 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 204 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 TELE COMM 205 F 3' - 0" 7' - 0" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 206 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 STORAGE 301 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 302 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS 303 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 304 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS 305 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 306 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS A1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY A1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR A2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR A3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
B1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY B1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR B2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR B3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
C1A F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY C1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 12 STAIR C2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR C3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
D1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY D1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR D2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR D3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
E1A F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY E1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR E2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR E3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
F1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY F1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR F2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR F3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR
1/4" = 1'-0"
FRAME TYPES
1/4" = 1'-0"
DOOR TYPES
GENERAL SHEET NOTES
DOOR SCHEDULE LEGEND
HM HOLLOW METAL
1. ALL DOORS SHALL BE 1 3/4" THICK U.N.O.
DOOR NOTES
1. SEE FLOOR PLANS FOR DOOR QUANTITIES, LOCATIONS, AND
SWINGS.
2. ALL EXTERIOR "HM" DOORS SHALL BE INSULATED STEEL DOOR
SYSTEMS AND SHALL COMPLY WITH UFC 4-010-01 AND ASTM
F2248.
3. ALL INTERIOR DOORS SHALL BE HEAVY DUTY U.N.O.
4. PROVIDE SEALANT AROUND FULL PERIMETER OF FRAMES,
BOTH SIDES OR PARTITIONS, ECT.
5. ALL GLAZING UNITS IN DOORS SHALL BE AS INDICATED AND
SPECIFIED.
6. PROVIDE GROUTED FRAMES WHERE NEEDED FOR FIRE OR
SOUND RATING PER SPECIFIED ASSEMBLY REQUIREMENTS.
7. PROVIDE GASKET WEATHER STRIPPING SEAL AND DOOR
BOTTOM AT INTERIOR DOORS FOR AIR BARRIER SEAL.
8. PROVIDE LOUVERS IN MECHANICAL AND ELECTRICAL ROOM
DOORS
GENERAL SHEET NOTES
1 2
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt
7/20/2021 4:41:55 PM
JU
LY
W
2H N
-2 1-
B-
R .R
U
PP
E
R .R
U
PP
E
S.
B
AR
BI
N A
1-
-1
A-610
R O
O M
F
IN
IS
H
S C
H
ED
U
LE
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
P.
S
U
LL
IV
AN
READY TO ADVERTISE (RTA)
UNIT FINISH SCHEDULE
ROOM NO ROOM NAME
WALL FINISH BASE FINISH FLOOR CEILING
NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT. FIN. MAT. FIN. HEIGHT 01 KITCHEN/DINING PT GWB PT GWB PT GWB CWT / PT GWB RB RB RB RB CONC LVT EXP/GWB PT 8' - 0"
02 BEDROOM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT EXP PT 8' - 0"
03 CLOSET PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 7' - 0"
04 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"
05 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"
06 BEDROOM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT EXP PT 8' - 0"
07 CLOSET PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 7' - 0"
08 W/D PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 8' - 0"
09 MECH PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"
BUILDING FINISH SCHEDULE
ROOM NO ROOM NAME
WALL FINISH BASE FINISH FLOOR CEILING
NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT. FIN. MAT. FIN. HEIGHT 101 LOBBY PT GWB PT GWB / PT CMU PT GWB PT GWB / PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"
102 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"
103 JANITOR CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"
104 STORAGE PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"
105 ACTIVITY PT GWB / PT CMU PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"
107 MECH EQ &
RISER
PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
108 FA CP PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
109 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
110 TELECOMM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SDVCT EXP PT 8' - 4"
111 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
112 EQ RM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
113 MECH ROOM PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 11"
114 EQ RM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"
115 ELECTRICAL PT CMU PT CMU PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"
116 MECH EQ PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 0"
117 MECH ROOM PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 11"
201 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
202 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"
203 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
204 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"
205 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
206 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"
207 ELEVATED EQUIPMENT
PLATFORM
PT CMU PT CMU PT CMU PT CMU NONE NONE NONE NONE CONC SC EXP - CEILING HEIGHT VARIES
208 ELEVATED EQUIPMENT
PLATFORM
PT CMU PT CMU PT CMU PT CMU NONE NONE NONE NONE CONC SC EXP - CEILING HEIGHT VARIES
301 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
302 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
303 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
304 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
305 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
306 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"
A1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES A2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES A2/F2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES A3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES A3/F3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES A/F CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES B2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES B2/E2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES B3/E3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B/E CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES C2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES C2/D2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES C3/D3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C/D CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES D1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES D2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES D3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES E1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES E2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES E3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES F1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES F2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES F3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES
FINISH SCHEDULE LEGEND
ACT ACOUSTIC CEILING TILE
CPT CARPET TILE
CONC CONCRETE
CWT CERAMIC WALL TILE
CWB CERAMIC WALL BASE
CMU CONCRETE MASONRY UNIT
EXP EXPOSED
GWB GYPSUM WALL BOARD
PFT PORCELAIN FLOOR TILE
PT PAINT
PWT PORCELAIN WALL TILE
RB RESILIENT BASE
SDVCT STATIC DISSIPATIVE TILE
SC SEALED CONCRETE
VCT VINYL COMPOSITION TILE
EG ENTRANCE GRILLE
STL SOLID COLOR RUBBER TILE
GENERAL NOTES
1. REFERENCE SPECIFICATION SECTION 09 06 90 "BUILDING
COLOR AND FINISH SCHEDULE" FOR INFORMATION
REGARDING COLOR AND FINISH.
2. COLOR BOARDS AND PROPOSED SAMPLES SHALL NOT BE
SUBMITTED INDIVIDUALLY BUT IN A COMPLETE SET WITH
ALL SAMPLES.
A. EXPOSED CONCRETE SLABS SHALL HAVE THE
FOLLOWING:
EXTERIOR SLABS SHALL HAVE A SEALER
B. INTERIOR SLABS NOT RECEIVING A FINISH SHALL
HAVE A SEALER
C. INTERIOR SLABS WITH VCT OR CARPET SHALL HAVE
A TROWEL FINISH. A FILLER SHALL BE ADDED AS
NEEDED AT CONCRETE CONTROL JOINTS TO ENSURE
THAT JOINTS DO NOT BLEED THROUGH.
D. INTERIOR SLABS WITH TILE SHALL HAVE A STEEL
TROWEL AND FINE BROOM FINISH FREE OF CURING
COMPOUNDS.
3. CORNER GUARDS SHALL BE LOCATED AT ALL EXPOSED
CORNERS IN CIRCULATION U.N.O.
4. SEE I-SHEETS FOR WALL/ FLOOR TILE PATTERNS.
ROOM FINISH SCHEDULE NOTES
1. RECESSED FLOOR MAT SHALL BE PROVIDED AT MAIN
ENTRANCES
2. PROVIDE RIGIDLY FIXED 3/4" A-C FIRE RETARDANT
TREATED PLYWOOD 8' HIGH ON ALL WALL SURFACES AT
COMMUNICATION ROOM AND ELECTRICAL ROOM.
PLYWOOD SHALL BE MOUNTED WITH THE BASE OF THE
BOARD AT 2' AFF AND EXTENDED TO 8' AFF. WALL SHALL
BE GYPSUM BOARD WITH PLYWOOD ATTACHED TO STUDS
BEHIND AND PAINTED TO MATCH INTERIOR PAINT COLOR.
COORDINATE WITH ELECTRICAL/ COMMUNICATION
DRAWINGS FOR PANEL PLACEMENT.
3. SEE REFLECTED CEILING PLAN FOR LOCATIONS OF
ACCESS PANELS IN GYPSUM BOARD CEILINGS.
4. REFERENCE I-SHEETS FOR FLOOR PATTERN AND ACCENT
PAINT DETAILS.
5. PROVIDE MOISTURE RESISTANT GYPSUM BOARD WALL
AND CEILING IN ALL RESTROOMS AND JANITOR CLOSETS.
6. PROVIDE VERTICAL AND HORIZONTAL MOVEMENT JOINTS
IN TILE FINISH IAW TILE COUNCIL OF NORTH AMERICA. -
EJ171-09 UNLESS THE TILE MANUFACTURER'S
RECOMMENDED METHOD PROVIDES GREATER
PROTECTION.
7. TILE INSTALLATION SHALL UTILIZE THE FOLLOWING TILE
COUNCIL OF NORTH AMERICA, INC. METHODS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_INT_R21_k6endrgr.rvt
7/20/2021 4:53:37 PM
JU
LY
W
2H N
-2 1-
B-
V.
R
O
BE
R
SO
N
V.
R
O
BE
R
SO
N
S.
B
AR
BI
N A
1-
-1
I-601
IN
TE
R
IO
R U
N
IT
A N
D R
O O
M F
IN
IS
H S
C H
ED
U
LE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
P.
S
U
LL
IV
AN
READY TO ADVERTISE (RTA)
INTERIOR UNIT FINISH SCHEDULE
ROOM NO ROOM NAME
WALL FINISH BASE FINISH FLOOR CEILING
NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FIN. FIN.
01 KITCHEN/DINING PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2, 3, 8
02 BEDROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2
03 CLOSET PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2
04 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6, 9, 10 05 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6, 9, 10
06 BEDROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2
07 CLOSET PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2
08 W/D PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2
09 MECH PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
INTERIOR ROOM FINISH SCHEDULE
ROOM NO ROOM NAME
WALL FINISH BASE FINISH FLOOR CEILING NOTES & REMARKS
(SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FIN. FIN.
101 LOBBY PT-2 PT-2 PT-2 PT-2 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
102 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6 103 JANITOR CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6
104 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
105 ACTIVITY PT-2 PT-2 PT-2 PT-2 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1, 7
107 MECH EQ &
RISER
PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
108 FA CP PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
109 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
110 TELECOMM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SDT-1 PT-5 5
111 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
112 EQ RM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
113 MECH ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
114 EQ RM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
115 ELECTRICAL PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
116 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
117 MECH ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
201 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
202 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
203 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
204 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5
205 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5 1
206 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
301 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
302 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
303 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
304 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
305 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
306 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5
A1 STAIR PT-3 PT-3 PT-3 PT-3 RB-1 RB-1 RB-1 RB-1 STF-1/STL-1 EXP
A2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
A2/F2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
A3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
A3/F3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
A/F CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
B1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
B2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
B2/E2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
B3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
B3/E3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
B/E CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
C1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
C2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
C2/D2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
C3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
C3/D3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
C/D CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1
D1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
D2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
D3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
E1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
E2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
E3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
F1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
F2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP
F3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5
SHEET NOTES
GENERAL NOTES
1. WS-1 WINDOW SHADES SHALL BE PROVIDED AT ALL
EXTERIOR WINDOWS, EXCEPTING CURTAIN WALL.
2. REFER TO A-SHEETS FOR LOCATIONS OF CG-1 CORNER
GUARD PLACEMENT.
3. REFERENCE SPECIFICATION SECTION 09 06 00
"SCHEDULE FOR FINISHES" FOR INFORMATION
REGARDING COLOR & FINISH. ALL FINISHES HAVE BEEN
SELECTED AS A BASIS OF DESIGN.
4. ALL INTERIOR COLORS SHALL BE SUBMITTED FOR
APPROVAL PER DIRECTIONS IN SPECIFICATION 09 06 00.
COLOR BOARDS AND PROPOSED SAMPLES SHALL NOT
BE SUBMITTED INDIVIDUALLY BUT IN A COMPLETE SET
WITH ALL SAMPLES.
5. ALL CASEWORK HARDWARE TO BE MANUFACTURED
STANDARD HEAVY DUTY.
6. PAINT ALL SUPPLY & RETURN AIR MECHANICAL GRILLS /
DIFFUSERS ON GWB CEILINGS & WALLS TO MATCH
ADJACENT COLOR.
7. PAINT ALL EXPOSED STRUCTURE TO MATCH ADJACENT
MATERIAL.
8. REFER TO A-SHEETS FOR ALL MILLWORK DETAILS.
REFERENCE SPECIFICATION SECTION 09 06 00
"SCHEDULE FOR FINISHES" FOR ADDITIONAL
INFORMATION REGARDING COLOR AND FINISH.
9. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL
TOILETS, SHOWER AREAS, AND WALLS ADJACENT TO
SINKS.
10. REFER TO SPECIFICATION 03 30 00 CAST-IN-PLACE
CONCRETE FOR FINISH DETAILS.
11. SUBMIT NFPA CLASS RATINGS OF ALL INTERIOR FINISHES
TO QFPE FOR APPROVAL. ALL INTERIOR FINISHES SHALL
COMPLY WITH UFC 3-600-01 AND NFPA 101, CHAPTER 10.
1. VCT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,
CENTERED IN THE CORRIDORS AND ROOMS.
2. LVT-1 PLANKS SHALL BE INSTALLED IN A RANDOM
STAGGER PATTERN. PATTERN SHALL RUN
HORIZONTALLY (PLAN EAST TO WEST) THROUGHOUT THE
UNITS, CENTERED IN THE UNIT KITCHEN.
3. CWT-1 SHALL BE INSTALLED IN A 1/2 OFFSET,
HORIZONTAL RUNNING BOND PATTERN FOR ALL UNIT
KITCHEN BACKSPLASHES. PATTERN SHALL BE CENTERED
OVER THE SINK.
4. REFER TO DETAIL 1 ON SHEET I-502 FOR CWT-1/CWT-2
TYPICAL WALL TILE PATTERN.
5. SDT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,
CENTERED IN THE ROOM.
6. PFT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,
CENTERED IN THE ROOM.
7. PL-1 SHALL BE USED FOR KITCHEN CABINETS IN THE
ACTIVITY ROOM.
8. PL-2 SHALL BE USED FOR KITCHEN CABINETS IN ALL
UNITS.
9. PL-3 SHALL BE USED FOR BATHROOM CABINETS IN ALL
UNITS.
10. SS-2 SHALL BE USED FOR ALL UNIT SHOWER WALLS AND
FLOOR PANS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\K6ENDKTD\Documents\FY21_PN95039_BLDG315_PLUMB_R21_K6ENDKTD.rvt
7/23/2021 1:07:01 PM
JU
LY
W
2H N
-2 1-
B-
L.
SA
LA
S
L.
SA
LA
S
S.
BA
R
BI
N A
1-
-1
PL601
PL
U
M
BI
N G
S C
H
ED
U
LE
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
K.
D
IX
O
N
READY TO ADVERTISE (RTA)
WCO WALL CLEANOUT WALL CONCURRENT SIZE WITH CONNECTED PIPE, MAX 6"
FCO FLOOR CLEANOUT FLOOR CONCURRENT SIZE WITH CONNECTED PIPE, MAX 6"
P-17 WASHING MACHINE WALL 3/4" 3/4" 1 1/2" 1 1/2"
P-12 MOP SINK FLOOR 1/2" 1/2" 3" 1 1/2" LOCATED IN JANITOR'S CLOSETS, MOP RECEPTOR TYPE, PRE-CAST, TERRAZO.
P-11A WATER COOLER (ADA) WALL 1/2" 1 1/2" 1 1/2" HI/LOW STYLE, PROVIDE WITH INTEGRATED BOTTLE FILLER
P-10 SHOWER WALL 1/2" 1/2" 2" SIDE OUTLET DISCHARGE TYPE
P-7 KITCHEN SINK COUNTER 1/2" 1/2" 1 1/4" 1 1/4"
P-5 LAVATORY COUNTER 1/2" 1/2" 1 1/4" 1 1/4" MANUAL FAUCET
P-4A LAVATORY (ADA) WALL 1/2" 1/2" 1 1/4" 1 1/4" MANUAL FAUCET, PADDLE-TYPE
P-2A WATER CLOSET (ADA) FLOOR 1" 4" 2" FLUSH VALVE, MANUAL DUAL FLUSH
P-1 WATER CLOSET FLOOR 1" 4" 2" FLUSH TANK, MANUAL DUAL FLUSH, WALL EXITING
WH-1 WALL HYDRANT WALL 3/4" FREEZEPROOF
FD-1 FLOOR DRAIN FLOOR 3" 1 1/2" IN MECHANICAL ROOMS PROVIDE TRAP PRIMER, OTHERWISE PROVIDE TRAP GUARD.
MARK DESCRIPTION MOUNTING C.W. (IN) H.W. (IN) WASTE (IN) VENT (IN) NOTES
PLUMBING FIXTURE SCHEDULE
THERMOSTATIC MIXING VALVE SCHEDULE
MARK LOCATION FLOW RATE
(GPM)
COLD E.W.T.
(F)
HOT E.W.T.
(F)
RECIRCULATION E.W.T.
(F)
MIXED L.W.T.
(F)
MAX. PRESSURE DROP
(PSI) NOTES
TMV-1 MECHANICAL ROOM 117 115 GPM 55 °F 140 °F 80 °F 120 °F 5.00 psi
DOMESTIC WATER EXPANSION TANK SCHEDULE
MARK LOCATION
ACCEPTANCE VOLUME
(GAL)
MINIMUM TANK PRE-CHARGE PRESSURE
(PSI)
OPERATING PRESSURE MAX.
(PSI) NOTES
DET-1 MECHANICAL ROOM 117 37.6 70 80 1
HOT WATER GENERATOR SCHEDULE
MARK TYPE
STORAGE
CAPACITY (GAL)
STEAM HOT WATER
NOTES
FLOW
(LB/HR)
PRESSURE
(PSI)
HEATING CAPACITY
(MBH) E.W.T (F) L.W.T. (F)
HWG-1 HOT WATER GENERATOR 940 584 15 551 55 140 1
CIRCULATING PUMP SCHEDULE
MARK SERVICE CAPACITY (GPM) HEAD (FT) HP (MAX) NOTES
DWRP-1 HOT WATER RETURN 5.04 9.5 1/8 IN-LINE BRONZE
NOTES:
1. PRESSURE RELIEF VALVE SHALL BE SET TO 10 PSI ABOVE OPERATING PRESSURE OR 10 PSI BELOW THE MANUFACTURER'S LISTED MAX PRESSURE FOR
THE EQUIPMENT IN THE SYSTEM.
NOTES:
1. PROVIDE VERTICAL JACKETED STORAGE TANK.
2. PROVIDE WITH MANUFACTURER RECOMMENDED PACKAGED CONTROLLER.
3. PROVIDE WITH DOUBLE WALL TUBE BUNDLE.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
JU
L2
PBB
ELECTRICAL
PANEL TR1
12" CABLE
RUNWAY
TELECOM
RACKS
2 - 4" CONDUITS TO
MANHOLE FOR NIPR
TELECOMM
3 - 4" CONDUITS
TO ATTIC
DSS-2
1 - 4" CONDUIT TO
5 FT LINE FOR
PRIVATIZED
TELEPHONE
1' - 6"
SERVICE
PROVIDER
SPACE
EQ RM
CATV
BACKBOARDS
6 EXISTING
CONDUITS
TO ATTIC
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
NORTH ARROW
GENERAL SHEET NOTES
KEY PLAN
PLAN NORTH
C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt
7/26/2021 9:24:59 AM
JU
LY
W
2H N
-2 1-
B-
O . A
N D
ER
SO
N
O . A
N D
ER
SO
N
S.
B
AR
BI
N A
1-
-1
TN401
EN
LA
R G
ED
T
EL
EC
O M
M U
N
IC
AT
IO
N S
PL
AN
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
R . D
AV
IS
READY TO ADVERTISE (RTA)
1/2" = 1'-0"
ENLARGED TELECOMMUNICATIONS ROOM 1101
1/2" = 1'-0"
ENLARGED EQUIPMENT RM 1142
1 PROVIDE FIRE RATED PENETRATIONS THROUGH THE WALL
CONDUITS. COORDINATE FIRE RATING WITH SHEET A003.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
TELECOM
ROOM 110
12 STRAND SM FOC
TO MANHOLE
1ST FLOOR
FIBER
PP IN
RACK
(2) 4-INCH CONDUITS
TO MANHOLE
NOTE 1
TELECOMMUNICATIONS CONDUIT RISER DIAGRAM NOTES:
1. PROVIDE ONE CONDUIT WITH 3-INCH, 3-CELL FABRIC MESH INNERDUCT WITH TRACER WIRE. ALL
EMPTY DUCTS SHALL CONTAIN A PULL STRING. SEE TN501 FOR CONDUIT TYPE.
2. PROVIDE ONE EMPTY CONDUIT FOR PRIVATE TELEPHONE SERVICE PROVIDER. ALL EMPTY DUCTS
SHALL CONTAIN A PULL STRING AND TRACER WIRE. SEE TN501 FOR CONDUIT TYPE.
3. EXISTING TELECOMMUNICATIONS CONDUIT MAY BE REUSED TO THE MAXIMUM EXTENT POSSIBLE.
4. PROVIDE NEW CONDUIT IN SLEEPING UNITS TO EXTEND FROM EXISTING CONDUIT TO NEW
OUTLET LOCATIONS.
5. ALL INTERIOR TELECOMMUNICATIONS CONDUIT SHALL BE EMT UNLESS OTHERWISE NOTED.
TELECOM
ROOM 110
(1) 4-INCH CONDUIT
TO 5-FOOT LINE
NOTE 2
2ND FLOOR
3RD FLOOR
ATTIC
NEW
18" X 18" X 6"
JUNCTION
BOX
NOTE 3
EXISTING
CONDUIT
(TYP)
NOTE 3
NEW
CONDUIT
(TYP)
NOTE 4
1ST FLOOR
2ND FLOOR
3RD FLOOR
ATTIC
1ST FLOOR
C/D WING B/E WING A/F WING
NEW 4"
CONDUIT
(TYP)
TELECOMMUNICATIONS CATV RISER DIAGRAM NOTES:
1. SEE TELECOMMUNICATIONS PLANS FOR LOCATIONS AND QUANTITIES OF CATV OUTLETS.
2. OSP CATV CABLE SHALL BE GFGI.
3. EXISTING CATV BACKBOARDS AND HEAD-END EQUIPMENT SHALL NOT BE DEMOLISHED. CATV CABLING, AND
CONDUIT MAY BE REUSED TO THE MAXIMUM EXTENT POSSIBLE. DEMOLISH ALL CATV OUTLETS.
4. PROVIDE NEW CATV OUTLETS.
2ND FLOOR
TV TV
3RD FLOOR
TV TV
ROOM 114
ATTIC
EXISTING
WIREWAY
TO ATTIC
TVTV
EXISTING
RG-6 (TYP)
NEW CATV
OUTLETS (TYP)
1ST FLOOR
TELECOMMUNICATIONS GROUNDING RISER DIAGRAM NOTES:
1. BOND ALL COMMUNICATIONS EQUIPMENT (BOND RACKS, PROTECTOR MODULES, EQUIPMENT
ENCLOSURES, CABLE TRAYS, AND METALLIC CONDUITS, ETC.) TO THE PBB WITH CONDUCTORS SIZED PER TIA 607-C. EACH BOND SHALL HAVE ITS OWN DEDICATED BONDING CONDUCTOR TO THE PBB.
2. BOND PBB TO NEARBY BUILDING STEEL WITH CONDUCTORS SIZED PER TIA 607-C.
MAIN
NIPR
TR110
1ST FLOOR
BLDG
STEEL
COMM
EQUIP
PANEL
#6 AWG
#1/0 AWG
TO MAIN ELECTRICAL
SERVICE GROUND
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt
7/26/2021 9:25:09 AM
JU
LY
W
2H N
-2 1-
B-
O . A
N D
ER
SO
N
O . A
N D
ER
SO
N
S.
B
AR
BI
N A
1-
-1
TN601
TE
LE
C O
M M
U N
IC
AT
IO
N
S R
IS
ER
D
IA
G R
AM
S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
R . D
AV
IS
READY TO ADVERTISE (RTA)
TELECOMMUNICATIONS FIBER OPTIC RISER DIAGRAM3
TELECOMMUNICATIONS CONDUIT RISER DIAGRAM2
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
TELECOMMUNICATIONS CATV RISER DIAGRAM1
TELECOMMUNICATIONS GROUNDING RISER DIAGRAM4
9 8
SERVICE ENTRANCE CONDUITS. SEE TN601 FOR QUANTITIES.
NOT USED
FIBER OPTIC CABLES. SEE TN601 FOR QUANTITIES.
CABLE MANAGEMENT RINGS.
20-FT FIBER MAINTENANCE LOOP.
NOT USED
NOT USED
TELECOMMUNICATIONS PRIMARY BONDING BUSBAR.
QUAD 120 VAC RECEPTACLES, MOUNTED 18" AFF. QUANTITIES AND LOCATIONS PER POWER PLANS.
FIRE-RETARDANT, 3/4" THICK, 8' TALL, WIDTH AS INDICATED ON PLANS, TYPE A/C PLYWOOD BACKBOARD.
PLYWOOD MUST BE APPROVED BY NEC QA/QC BEFORE IT IS INSTALLED. INSTALL PLYWOOD BACKBOARDS WITH THE "A" SIDE FACING OUT AND THE MANUFACTURER'S FIRE-RETARDANT STAMP SHALL BE VISIBLE.
12-PORT (1U), SINGLE-MODE, FIBER OPTIC PATCH PANELS WITH FIBER TRAY AND DUPLEX "LC" CONNECTORS
FOR SERVICE ENTRANCE AND RISER FIBER OPTIC CABLES. QUANTITES AS REQUIRED.
VERTICAL AND FRONT AND REAR HORIZONTAL CABLE WIRE MANAGEMENT, QUANTITIES AS REQUIRED.
LOCAL AREA NETWORK (LAN) ELECTRONICS SHALL BE GFGI. CONTRACTOR SHALL FURNISH AND INSTALL
FIBER OPTIC PATCH CABLES PLUS 25% SPARE.
RACK-MOUNTED, CATEGORY 6, 48-PORT, RJ45 PATCH PANELS FOR COMMERICAL. PATCH PANEL QUANTITIES SHALL BE AS REQUIRED PLUS 25% SPARE FOR FUTURE GROWTH. ALL PORTS SHALL BE POPULATED.
RACK-MOUNTED, CATEGORY 6, 48-PORT, RJ45 PATCH PANELS FOR NIPR. PATCH PANEL QUANTITIES SHALL
BE AS REQUIRED PLUS 25% SPARE FOR FUTURE GROWTH. ALL PORTS SHALL BE POPULATED.
RACK-MOUNTED, UNINTERRUPTIBLE POWER SUPPLY (UPS) SHALL BE GFGI.
RECEPTACLES. TYPES, QUANTITIES, AND MOUNTING INSTRUCTIONS PER POWER SHEETS.
STANDARD, 7-FT, 19-INCH ALUMINUM RACKS. ALL RACKS SHALL HAVE VERTICAL WIRE MANAGEMENT
ASSEMBLIES AND VERTICALLY-MOUNTED RACK GROUNDING BUSBARS INSTALLED.
CABLE RUNWAY. PROVIDE TRANSITION TRAYS TO RACKS SO THAT MINIMUM CABLE BENDING RADII CAN BE
MAINTAINED.
CATEGORY 6 CABLING TO OUTLETS VIA CONDUIT PATHWAYS. OUTLET QUANTITIES AND LOCATIONS PER
TELECOMMUNICATIONS PLANS. SEE TN501 FOR OUTLET DETAILS.
CATEGORY 6 CABLING TO OUTLETS VIA CONDUIT PATHWAYS. OUTLET QUANTITIES AND LOCATIONS PER TELECOMMUNICATIONS PLANS. SEE TN501 FOR OUTLET DETAILS AND TN601 FOR CONDUIT PATHWAYS.
PBB
18 18
TR110 WALL DIAGRAM AND KEYED NOTES:
NOT TO SCALE
SHEET ID
D R
AW
N
B Y:
D
ES
IG
N
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
D
C
B
A
C
AT
EG
O
R Y
C O
D E:
AN
SI
D
E
F
G
2 3 4 5 6 7 8 9 10
C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt
7/26/2021 9:25:19 AM
JU
LY
W
2H N
-2 1-
B-
O . A
N D
ER
SO
N
O . A
N D
ER
SO
N
S.
B
AR
BI
N A
1-
-1
TN602
TE
LE
C O
M M
U N
IC
AT
IO
N
S W
AL
L
D
IA
G
AR
M S
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A
VE
SA
VA
N
N
AH
, G A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
R
EP
AI
R
B
AR
R
AC
K
BU
IL
D
IN
G
FY
, P N
VO
LU
M
E
-B U
IL
D
IN
G
R . D
AV
IS
READY TO ADVERTISE (RTA)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
J U
L
MAIN TR WALL DIAGRAM AND KEYED NOTES1
| SF505 FRAMING DETAILS |
| A-403 ENLARGED INTERIOR ELEVATION - LIVING UNIT |
| A-404 ENLARGED INTERIOR ELEVATIONS - SERVICE MODULE |
| A-603 DOOR SCHEDULE AND TYPES |
| A-610 ROOM FINISH SCHEDULE |
| I-601 INTERIOR UNIT AND ROOM FINISH SCHEDULES |
| PL601 PLUMBING SCHEDULES |
| TN401 ENLARGED TELECOMMUNICATIONS PLANS |
| TN601 TELECOMMUNICATIONS RISER DIAGRAMS |
| TN602 TELECOMMUNICATIONS WALL DIAGARMS |
File details come from the government source that posted it. Updated .