This is an invitation for bid for repair and renovation work on Barracks Building 315 at Fort Gordon, Georgia. The project scope includes replacement of failing HVAC systems and components, repair of moisture and mildew damage, replacement of exterior and interior components and finishes, upgrade of latrines, lighting, and fire alarm and mass notification systems. Work will involve demolition, abatement of hazardous materials, and installation of new systems and components to comply with accessibility standards and increase quality of life for soldiers. The contract is set aside for small businesses under NAICS code 236220 with an estimated value between $10-25 million. Responses are due in accordance with FAR Part 14 procedures. The point of contact listed is Mr. Lennie K. Mattis of the Army Corps of Engineers Savannah District.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES:

1. WHERE THREE BARS OCCUR, CENTER BAR SHALL BE HAVE 90 DEGREE STANDARD HOOK.

TYPICAL FOOTING

REINFORCING, (TYP)

PLAN AT

CORNER

PLAN AT

INTERSECTION

BARS, (TYP)

0" BETWEEN

3' - 0"

3'

0"

'L' BAR TO MATCH

HORIZONTAL

REINFORCING

BA

R

S, (T

YP

0" B

ET

W

EE

N

TYPICAL FOOTING

REINFORCING, (TYP)

1'

6"

HOOKED SPLICE BAR

TO MATCH

HORIZONTAL FOOTING

OR WALL

REINFORCING

BARS, (TYP)

0" BETWEEN

1' - 6" 1' - 6"1' - 6"

WALL CORNER

OPENING - WALL TERMINATION

VERTICAL WALL

REINFORCING

WALL INTERSECTION

VERTICAL WALL

REINFORCING

NOTES:

1. INTERMEDIATE HORIZONTAL BOND BEAM REINFORCING SHALL TERMINATE AT CMU CONTROL

JOINTS. REINFORCING FOR BOND BEAMS AT TOP OF WALLS SHALL BE CONTINUOUS.

2. HORIZONTAL BARS SHALL BE ANCHORED AROUND VERTICAL BARS WITH A STANDARD HOOK.

VERTICAL WALL

REINFORCING

EQ EQ

EQ

EQ

EQ

EQ

EQ EQ

SEE PLAN

WALL

OPENING

EQ EQ

HORIZONTAL BOND BEAM

REINFORCING

HORIZONTAL BOND BEAM

REINFORCING

HORIZONTAL BOND

BEAM

REINFORCING

WALL CONTROL JOINT

(1) FULL HEIGHT VERTICAL BAR IN

GROUT FILLED CELLS ON EACH SIDE OF

JOINT TO MATCH WALL REINFORCING

CONTROL JOINT WITH FULL HEIGHT

BACKER ROD AND SEALANT - REFER TO

ARCHITECTURAL DWGS FOR DETAILS

NOTES:

1. CONTROL JOINT SPACING SHALL NOT EXCEED 2X WALL HEIGHT OR 20'-0" MAX.

2. CONTROL JOINTS SHALL EXTEND FULL HEIGHT OF CMU WALL.

3. BOND BEAM REINFORCING AT OR NEAREST ROOF OR FLOOR ABOVE SLABS ON GRADE

SHALL BE CONTINUOUS THROUGH CONTROL JOINTS.

4. JOINT REINFORCEMENT SHALL BE DISCONTINUOUS AT CONTROL JOINTS UNLESS NOTED

OTHERWISE ON PLANS AND DETAILS.

5. BACKER ROD MAY BE OMITTED IF FULL WIDTH PREMOLDED CONTROL JOINT KEY IS

EMPLOYED. COORDINATE JOINT DETAILS WITH ARCHITECTURAL REQUIREMENTS.

EQ

EQ

CMU WALL

PREMOLDED CONTROL

JOINT KEY

3/8" JOINT

DISCONTINUOUS BOND

BEAM REINFORCEMENT,

(TYP)

8" MIN DEEP CONCRETE TIE BEAM

W/ (2) #4 AT TOP OF SLOPED WALLS,

STEP BLOCKS BELOW AS REQD

8" CMU WALL, SEE PLAN AND

SCHEDULE FOR REINFORCING

T/ WALL

VERTICAL DOWEL TO MATCH WALL

REINFORCING SIZE AND SPACING,

LAP SPLICE PER SCHEDULE

CONCRETE FOOTING -

SEE PLAN AND SCHEDULE

FOR SIZE AND REINFORCING

1/2" PREMOLDED JOINT FILLER

CONCRETE SLAB ON GRADE, SEE PLAN

0" SPCG

FURRING STUDS,

SEE ARCH

METAL PANELS,

SEE ARCH

SEE PLAN

5/8" DIA HD SCREW ANCHOR

W/ 4 3/4" MIN EMBED @ 16" OC

L4X4X1/4 DECK CLOSURE ANGLE

24" DEEP CMU BOND BEAM AT MECHANICAL

PLATFORM FLOOR REINFORCED

W/ (2) #4 CONT TOP AND BOTTOM IN GROUT

FILLED CELLS

8" CMU BOND BEAM AT BASE OF

WALL REINFORCED WITH (2) #4

CONT IN GROUT FILLED CELLS

METAL DECK, SEE PLAN

2-1/2" DEEP JOIST SUBSTITUTE,

SEE PLAN

JOIST, SEE PLAN

DECK EDGE PLATES,

SEE SF507

T/ FTG

(-) 1'-4"

BOND BEAM AT TOP OF WALL AND AT ROOF

BEARING LEVEL - SEE PLAN AND DETAILS

FOR LOCATIONS AND REINFORCING

PLACE METAL LATH OR WIRE SCREEN

OVER CORES NOT TO BE FILLED

(SHEET METAL AND FELT PROHIBITED)

VERTICAL REINFORCING WITH MATCHING

DOWELS INTO FOUNDATION. SEE PLAN

FOR SIZE AND LOCATION. PROVIDE BAR

POSITIONERS PER PROJECT

SPECIFICATIONS SECTION 04 20 00.

HORIZONTAL JOINT REINFORCING @ 16"

OC STARTING AT FIRST COURSE ABOVE

FOUNDATION. LAP SPLICES 8". USE

PREFABRICATED L'S AND T'S AT WALL

INTERSECTIONS.

GROUT FILLED CELL AT REINFORCING

LOCATIONS - PLACE AND CONSOLIDATE

GROUT IN 5 FOOT LIFTS (MAX)

MORTAR CROSS WEBS ADJACENT TO

FILLED CELLS

ASTM C90 CMU UNITS IN RUNNING BOND

FOUNDATION OR THICKENED SLAB

SET FIRST COURSE IN

FULL MORTAR BEDDING

PROVIDE CLEAN OUT

OPENINGS AT GROUT

FILLED CELL LOCATIONS

16" MAX 16" MIN 16" MAX

(2)#4 HORIZ

GROUTED SOLID

EXTEND 24"

BEYOND EDGE

OF OPENING

GROUT

OPENING

AFTER

INSTALLING

CONDUIT

A

A A-A

STEEL COLUMN,

SEE PLAN

T/FTG

(-) 1'-4"

EXISTING WALL FOOTING

EXISTING FOUNDATION WALL

EXISTING EXTERIOR WALL

EXISTING FLOOR SLAB

T/EXISTING

(-) 4'-8"2" THICK X 2'-0" WIDE VOID FORM

4" CAPILLARY BARRIER

10 MIL VAPOR RETARDER

COMPACTED SUBGRADE

1/2" PREMOLDED JOINT FILLER

1' - 2"

EOC

1' - 1 1/2"

1' - 0"

SF501

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENXCTA\Documents\FY21_PN95039_BLDG315_STRUCT_R21_K6ENXCTA.rvt

7/20/2021 9:50:02 AM

JU

LY

W

2H N

-2 1-

B-

C . A

TK

IN

S

C . A

TK

IN

S

S.

B

AR

BI

N A

1-

-1

SF505

FR

AM

IN

G

D

ET

AI

LS

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

J.

W

H

IT

TA

KE

R

READY TO ADVERTISE (RTA)

TYPICAL CONT. FTG REINFORCING DETAIL2 TYPICAL CMU WALL REINFORCING DETAIL3

TYPICAL CMU WALL CONTROL JOINT DETAIL4

MECHANICAL ADDITION MASONRY WALL SECTION6

TYPICAL MASONRY CONSTRUCTION DETAIL1

CONDUIT OPENING THROUGH CMU FDN WALLS5 MECHANICAL ADDITION ABUTTING EXISTING7

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

058'

0"

SOLID SURFACE

PANELS

SCSCR

TR

GB

8'

0"

SOLID SURFACE PANELS

SCSCR

MG MC

TR

TP

GB

8'

0"

A-523

Sim

SOLID SURFACE PANELS

SCSCR

SH

8'

0"

5'

15 INCHES DEEP

CLOSET SHELF &

ROD

7'

0"

5'

15 INCHES DEEP

CLOSET SHELF &

ROD

7'

0"

5'

15 INCHES DEEP

CLOSET SHELF &

ROD

7'

0"

5'

15 INCHES DEEP

CLOSET SHELF &

ROD

7'

0"

2'

6" 1'

2"

4" 3'

0"

7'

0"

028'

0"

1'

0"

018'

0"

7'

0" 1'

0"

8'

0"

2'

6" 1'

2"

4" 3'

0"

7'

0"

2' - 0" 2' - 0" 2' - 6" 2' - 0"

8'

0"

GFGI

GFGI

UL 507

RANGE HOOD

A-523

A-523

A-523

GFGI GFGI

3'

0" 4"

1'

2" 2'

6"

7'

0"8'

0"

7'

0" 1'

0"

A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN CENTERLINES,

UNLESS NOTED OTHERWISE (U.N.O.).

B. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.

C. REFERENCE SHEETS A-601 & A-602 FOR PARTITION TYPES.

D. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR TYPICAL

TILE SIZE AND PATTERNS.

E. SLOPE SLABS TO FLOOR DRAINS, TYP.

F. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL TOILET

ACCESSORIES.

G. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL WALL HUNG

FIXTURES (LAVATORIES, URINALS, ETC.).

H. SHOWER ENCLOSURE SHALL BE FULL HEIGHT SOLID SURFACE AS INDICATED.

ALL OTHER AREAS SHALL HAVE FULL HEIGHT CERAMIC WALL TILE AS INDICATED.

I. REFERENCE SHEETS A-011, A-012, & A-013 FOR FIXTURE MOUNTING HEIGHTS.

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt

7/20/2021 4:35:29 PM

JU

LY

W

2H N

-2 1-

B-

R .R

U

PP

E

R .R

U

PP

E

S.

B

AR

BI

N A

1-

-1

A-403

EN

LA

R G

ED

IN

TE

R

IO

R

E

LE

VA

TI

O N

LI

VI

N

G U

N

IT

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

P.

S

U

LL

IV

AN

READY TO ADVERTISE (RTA)

1/4" = 1'-0"

BATHROOM1

1/4" = 1'-0"

BATHROOM2

1/4" = 1'-0"

BATHROOM3

1/4" = 1'-0"

BATHROOM4

4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 82

4 3 1 0 4 82

1/4" = 1'-0"

CLOSET5

1/4" = 1'-0"

CLOSET6

1/4" = 1'-0"

CLOSET7

1/4" = 1'-0"

CLOSET8

1/4" = 1'-0"

KITCHEN9

1/4" = 1'-0"

KITCHEN10

1/4" = 1'-0"

KITCHEN11

1/4" = 1'-0"

KITCHEN12

4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 824 3 1 0 4 82

MG

MC

TR

TP

ACCESSORY SCHEDULE

ACCESSORY DESCRIPTION TYPE MARK

GRAB BAR - VERTICAL GB

HOOK, GARMENT HK

MEDICINE CABINET MC

24"x36" MIRROR MG

SURFACE MOUNTED MOP/BROOM HOLDER MR

PAPER TOWEL DISPENSER/WASTE RECEPTACLE PDTWR

SHOWER CURTAIN & ROD SCSCR

WALL MOUNTED SOAP DISPENSER SD

SOAP HOLDER SH

SANITARY NAPKIN DISPOSER SND

SURFACE MOUNTED MULTI-ROLL TOILET TISSUE

DISPENSER

TP

24" TOWEL BAR TR

TOILET SEAT COVER DISPENSER - SURFACE TSCD

GENERAL SHEET NOTES

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

8'

0"

103 102 8'

0"

4'

6"

C1B

GFCIGFCIGFCIGFCI 5'

1/

2" M

IN

2'

4"

1' - 3"

PLUMBING

ACCESS

PANEL

8'

0"

1'

3"

101 1048'

0"

1058'

0"

8'

0"

A

4'

6"

3'

0"

AA

8'

0"

8'

0"

8'

0"

6'

0"

MR

2'

0"

1038'

0"

6'

0" 2'

0" MR

8'

0"

6'

0" 2'

0"

MR

GB1

GB2

MG

8'

0"

TP

SND

SD

GB1

GB28'

0"

TSCD

TP

SND

PTDWR

TSCD

TP

HK

4'

0"

MG

PTDWR

HK

A. ALL DIMENSIONS SHOWN ARE TO FACE OF STUD, OR COLUMN CENTERLINES,

UNLESS NOTED OTHERWISE (U.N.O.).

B. REFER TO "BUILDING COLOR & FINISH SCHEDULE" FOR TILE COLORS.

C. REFERENCE SHEETS A-601 & A-602 FOR PARTITION TYPES.

D. REFERENCE FINISH SCHEDULE FOR FINISH MATERIALS & I-SHEETS FOR TYPICAL

TILE SIZE AND PATTERNS.

E. SLOPE SLABS TO FLOOR DRAINS, TYP.

F. WOOD BLOCKING SHALL BE PROVIDED IN WALL ASSEMBLIES FOR ALL TOILET

ACCESSORIES.

G. REINFORCEMENT AT METAL STUD WALLS SHALL BE LOCATED AT ALL WALL HUNG

FIXTURES (LAVATORIES, URINALS, ETC.).

H. SHOWER ENCLOSURE SHALL BE FULL HEIGHT SOLID SURFACE AS INDICATED.

ALL OTHER AREAS SHALL HAVE FULL HEIGHT CERAMIC WALL TILE AS INDICATED.

I. REFERENCE SHEETS A-011, A-012, & A-013 FOR FIXTURE MOUNTING HEIGHTS.

2'

4' - 0" 2' - 6" 1' - 9"

8' - 3"

A-523

8'

0"

3' - 0" 3' - 0"

6' - 0" 2'

A-523

8'

0"

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt

7/20/2021 4:36:03 PM

JU

LY

W

2H N

-2 1-

B-

R .R

U

PP

E

R .R

U

PP

E

S.

B

AR

BI

N A

1-

-1

A-404

EN

LA

R G

ED

IN

TE

R

IO

R

E

LE

VA

TI

O N

S -S

ER

VI

C E

M O

D U

LE

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

P.

S

U

LL

IV

AN

READY TO ADVERTISE (RTA)

1/4" = 1'-0"

LOBBY1

1/4" = 1'-0"

LOBBY2

1/4" = 1'-0"

LOBBY3

1/4" = 1'-0"

LOBBY4

1/4" = 1'-0"

ACTIVITY ROOM5

1/4" = 1'-0"

ACTIVITY ROOM6

1/4" = 1'-0"

ACTIVITY ROOM7

1/4" = 1'-0"

ACTIVITY ROOM9

1/4" = 1'-0"

JANITOR10

1/4" = 1'-0"

JANITOR11

1/4" = 1'-0"

JANITOR13

1/4" = 1'-0"

RESTROOM14

1/4" = 1'-0"

RESTROOM15

1/4" = 1'-0"

RESTROOM16

1/4" = 1'-0"

RESTROOM17

GENERAL SHEET NOTES

4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 824 3 1 0 4 824 3 1 0 4 82

4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 82

4 3 1 0 4 82

4 3 1 0 4 824 3 1 0 4 82

4 3 1 0 4 82 4 3 1 0 4 82 4 3 1 0 4 82

4 3 1 0 4 82

ACCESSORY SCHEDULE

ACCESSORY DESCRIPTION TYPE MARK

GRAB BAR - VERTICAL GB

HOOK, GARMENT HK

MEDICINE CABINET MC

24"x36" MIRROR MG

SURFACE MOUNTED MOP/BROOM HOLDER MR

PAPER TOWEL DISPENSER/WASTE RECEPTACLE PDTWR

SHOWER CURTAIN & ROD SCSCR

WALL MOUNTED SOAP DISPENSER SD

SOAP HOLDER SH

SANITARY NAPKIN DISPOSER SND

SURFACE MOUNTED MULTI-ROLL TOILET TISSUE

DISPENSER

TP

24" TOWEL BAR TR

TOILET SEAT COVER DISPENSER - SURFACE TSCD

1/4" = 1'-0"

ACTIVITY ROOM8

1/4" = 1'-0"

ACTIVITY ROOM12

4 3 1 0 4 82

36" GRAB BAR

48" GRAB BAR

GB1

GB2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

EXTERIOR/INTERIOR

SINGLE DOORS

IN MASONRY WALL

4"

AS

S

C H

ED

4"

AS

S

C H

ED

2" AS SCHED 2" 2" AS SCHED 2"

INTERIOR

SINGLE DOORS

EXTERIOR

DOUBLE DOORS

IN MASONRY WALL

EXTERIOR

UNEVEN DOOR

IN MASONRY WALL W/ STEEL

PANEL TRANSOM

6'

8"

2"

2" AS SCHED 2"

8'

0"

7'

0"

2" 2"AS SCHED

4"

6"STEEL PANEL

EXTERIOR SINGLE DOOR

IN MASONRY WALL W/ STEEL

PANEL TRANSOM

8'

0"

7'

0"

2" 2"AS SCHED

4"

6"STL PANEL

TYPE F TYPE R

2'

0" 6"

4"

6"

TYPE DF TYPE UF

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt

7/20/2021 4:41:13 PM

JU

LY

W

2H N

-2 1-

B-

R .R

U

PP

E

R .R

U

PP

E

S.

B

AR

BI

N A

1-

-1

A-603

D O

O R

S C

H

ED

U

LE

A N

D T

YP

ES

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

P.

S

U

LL

IV

AN

READY TO ADVERTISE (RTA)

USACE_DOOR SCHEDULE

DOOR

NUMBERS TYPE

DOOR

FIRE

RATING

FRAME

HARDWARE COMMENTS:

SIZE

MATERIAL FINISH TYPE MATERIAL FINISH

DETAIL

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

01 F 3' - 0" 6' - 8" 1 3/4" WOOD STAIN 1⁄3-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 7 UNIT ENTRY 02 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 8 UNIT BEDROOM 03 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 10 UNIT CLOSET 04 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 9 UNIT BATHROOM 05 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 9 UNIT BATHROOM 06 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 8 UNIT BEDROOM 07 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 10 UNIT CLOSET 08 F 2' - 6" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 UNIT MECH

101 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 3/A-605 6/A-605 9/A-605 2 LOBBY 102 R 3' - 0" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 11 ACCESSIBLE RESTROOM 103 F 2' - 10" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 2/A-605 5/A-605 8/A-605 5 JANITORS 104 F 2' - 8" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 1/A-605 4/A-605 7/A-605 5 STORAGE 105 R 3' - 0" 6' - 8" 1 3/4" WOOD STAIN N/A 2 HM PAINT 1/A-605 4/A-605 7/A-605 12 ACTIVITY 107 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ & RISER RM 108 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 FA CP 109 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 110 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 TELE COMM 111 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 112 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 MECH EQ RM 113 DF 6' - 0" 7' - 0" 1 3/4" HM PAINT N/A 3 HM PAINT 2/A-604 5/A-604 8/A-604 3 MECH RM 114 F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 5 HM PAINT 1/A-604 4/A-604 7/A-604 4 MECH EQ RM 115 UF 5' - 0" 7' - 0" 1 3/4" HM PAINT N/A 4 HM PAINT 1/A-604 4/A-604 7/A-604 3 ELECTRICAL RM 116 DF 5' - 0" 6' - 8" 1 3/4" HM PAINT N/A 3 HM PAINT 1/A-604 4/A-604 7/A-604 3 MECH EQ RM 117 DF 6' - 0" 7' - 0" 1 3/4" HM PAINT N/A 3 HM PAINT 2/A-604 5/A-604 8/A-604 3 MECH RM 201 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 202 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 6 STORAGE 203 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 204 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 TELE COMM 205 F 3' - 0" 7' - 0" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 206 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 STORAGE 301 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 302 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS 303 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 304 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS 305 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 MECH EQ RM 306 F 3' - 0" 6' - 8" 1 3/4" HM PAINT 1/2-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 6 ATTIC ACCESS A1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY A1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR A2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR A3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

B1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY B1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR B2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR B3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

C1A F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY C1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 12 STAIR C2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR C3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

D1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY D1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR D2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR D3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

E1A F 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY E1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR E2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR E3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

F1A R 3' - 0" 7' - 0" 1 3/4" HM PAINT N/A 1 HM PAINT 3/A-604 6/A-604 9/A-604 1 STAIR ENTRY F1B R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-605 5/A-605 8/A-605 2 STAIR F2 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR F3 R 3' - 0" 6' - 8" 1 3/4" HM PAINT 1-HR 2 HM PAINT 2/A-604 5/A-604 8/A-604 2 STAIR

1/4" = 1'-0"

FRAME TYPES

1/4" = 1'-0"

DOOR TYPES

GENERAL SHEET NOTES

DOOR SCHEDULE LEGEND

HM HOLLOW METAL

1. ALL DOORS SHALL BE 1 3/4" THICK U.N.O.

DOOR NOTES

1. SEE FLOOR PLANS FOR DOOR QUANTITIES, LOCATIONS, AND

SWINGS.

2. ALL EXTERIOR "HM" DOORS SHALL BE INSULATED STEEL DOOR

SYSTEMS AND SHALL COMPLY WITH UFC 4-010-01 AND ASTM

F2248.

3. ALL INTERIOR DOORS SHALL BE HEAVY DUTY U.N.O.

4. PROVIDE SEALANT AROUND FULL PERIMETER OF FRAMES,

BOTH SIDES OR PARTITIONS, ECT.

5. ALL GLAZING UNITS IN DOORS SHALL BE AS INDICATED AND

SPECIFIED.

6. PROVIDE GROUTED FRAMES WHERE NEEDED FOR FIRE OR

SOUND RATING PER SPECIFIED ASSEMBLY REQUIREMENTS.

7. PROVIDE GASKET WEATHER STRIPPING SEAL AND DOOR

BOTTOM AT INTERIOR DOORS FOR AIR BARRIER SEAL.

8. PROVIDE LOUVERS IN MECHANICAL AND ELECTRICAL ROOM

DOORS

GENERAL SHEET NOTES

1 2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_ARCH_R21_k6endrgr.rvt

7/20/2021 4:41:55 PM

JU

LY

W

2H N

-2 1-

B-

R .R

U

PP

E

R .R

U

PP

E

S.

B

AR

BI

N A

1-

-1

A-610

R O

O M

F

IN

IS

H

S C

H

ED

U

LE

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

P.

S

U

LL

IV

AN

READY TO ADVERTISE (RTA)

UNIT FINISH SCHEDULE

ROOM NO ROOM NAME

WALL FINISH BASE FINISH FLOOR CEILING

NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT. FIN. MAT. FIN. HEIGHT 01 KITCHEN/DINING PT GWB PT GWB PT GWB CWT / PT GWB RB RB RB RB CONC LVT EXP/GWB PT 8' - 0"

02 BEDROOM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT EXP PT 8' - 0"

03 CLOSET PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 7' - 0"

04 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"

05 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"

06 BEDROOM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT EXP PT 8' - 0"

07 CLOSET PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 7' - 0"

08 W/D PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC LVT GWB PT 8' - 0"

09 MECH PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"

BUILDING FINISH SCHEDULE

ROOM NO ROOM NAME

WALL FINISH BASE FINISH FLOOR CEILING

NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT. FIN. MAT. FIN. HEIGHT 101 LOBBY PT GWB PT GWB / PT CMU PT GWB PT GWB / PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"

102 RESTROOM CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"

103 JANITOR CWT CWT CWT CWT CWB CWB CWB CWB CONC PFT EXP PT 8' - 0"

104 STORAGE PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"

105 ACTIVITY PT GWB / PT CMU PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC VCT EXP PT 8' - 0"

107 MECH EQ &

RISER

PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

108 FA CP PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

109 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

110 TELECOMM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SDVCT EXP PT 8' - 4"

111 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

112 EQ RM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

113 MECH ROOM PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 11"

114 EQ RM PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"

115 ELECTRICAL PT CMU PT CMU PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 0"

116 MECH EQ PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 0"

117 MECH ROOM PT CMU PT CMU PT CMU PT CMU RB RB RB RB CONC SC EXP PT 8' - 11"

201 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

202 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"

203 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

204 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"

205 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

206 STORAGE PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT EXP PT 8' - 4"

207 ELEVATED EQUIPMENT

PLATFORM

PT CMU PT CMU PT CMU PT CMU NONE NONE NONE NONE CONC SC EXP - CEILING HEIGHT VARIES

208 ELEVATED EQUIPMENT

PLATFORM

PT CMU PT CMU PT CMU PT CMU NONE NONE NONE NONE CONC SC EXP - CEILING HEIGHT VARIES

301 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

302 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

303 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

304 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

305 MECH EQ PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

306 ATTIC ACCESS PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC SC EXP PT 8' - 4"

A1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES A2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES A2/F2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES A3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES A3/F3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES A/F CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES B2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES B2/E2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES B3/E3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES B/E CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C1 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES C2 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES C2/D2 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C3 STAIR PT CMU PT GWB / PT CMU PT GWB / PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES C3/D3 CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES C/D CORRIDOR PT GWB PT GWB PT GWB PT GWB RB RB RB RB CONC VCT PT GWB PT CEILING HEIGHT VARIES D1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES D2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES D3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES E1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES E2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES E3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES F1 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES F2 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL EXP - CEILING HEIGHT VARIES F3 STAIR PT GWB / PT CMU PT GWB / PT CMU PT CMU PT GWB / PT CMU RB RB RB RB CONC STL PT GWB PT CEILING HEIGHT VARIES

FINISH SCHEDULE LEGEND

ACT ACOUSTIC CEILING TILE

CPT CARPET TILE

CONC CONCRETE

CWT CERAMIC WALL TILE

CWB CERAMIC WALL BASE

CMU CONCRETE MASONRY UNIT

EXP EXPOSED

GWB GYPSUM WALL BOARD

PFT PORCELAIN FLOOR TILE

PT PAINT

PWT PORCELAIN WALL TILE

RB RESILIENT BASE

SDVCT STATIC DISSIPATIVE TILE

SC SEALED CONCRETE

VCT VINYL COMPOSITION TILE

EG ENTRANCE GRILLE

STL SOLID COLOR RUBBER TILE

GENERAL NOTES

1. REFERENCE SPECIFICATION SECTION 09 06 90 "BUILDING

COLOR AND FINISH SCHEDULE" FOR INFORMATION

REGARDING COLOR AND FINISH.

2. COLOR BOARDS AND PROPOSED SAMPLES SHALL NOT BE

SUBMITTED INDIVIDUALLY BUT IN A COMPLETE SET WITH

ALL SAMPLES.

A. EXPOSED CONCRETE SLABS SHALL HAVE THE

FOLLOWING:

EXTERIOR SLABS SHALL HAVE A SEALER

B. INTERIOR SLABS NOT RECEIVING A FINISH SHALL

HAVE A SEALER

C. INTERIOR SLABS WITH VCT OR CARPET SHALL HAVE

A TROWEL FINISH. A FILLER SHALL BE ADDED AS

NEEDED AT CONCRETE CONTROL JOINTS TO ENSURE

THAT JOINTS DO NOT BLEED THROUGH.

D. INTERIOR SLABS WITH TILE SHALL HAVE A STEEL

TROWEL AND FINE BROOM FINISH FREE OF CURING

COMPOUNDS.

3. CORNER GUARDS SHALL BE LOCATED AT ALL EXPOSED

CORNERS IN CIRCULATION U.N.O.

4. SEE I-SHEETS FOR WALL/ FLOOR TILE PATTERNS.

ROOM FINISH SCHEDULE NOTES

1. RECESSED FLOOR MAT SHALL BE PROVIDED AT MAIN

ENTRANCES

2. PROVIDE RIGIDLY FIXED 3/4" A-C FIRE RETARDANT

TREATED PLYWOOD 8' HIGH ON ALL WALL SURFACES AT

COMMUNICATION ROOM AND ELECTRICAL ROOM.

PLYWOOD SHALL BE MOUNTED WITH THE BASE OF THE

BOARD AT 2' AFF AND EXTENDED TO 8' AFF. WALL SHALL

BE GYPSUM BOARD WITH PLYWOOD ATTACHED TO STUDS

BEHIND AND PAINTED TO MATCH INTERIOR PAINT COLOR.

COORDINATE WITH ELECTRICAL/ COMMUNICATION

DRAWINGS FOR PANEL PLACEMENT.

3. SEE REFLECTED CEILING PLAN FOR LOCATIONS OF

ACCESS PANELS IN GYPSUM BOARD CEILINGS.

4. REFERENCE I-SHEETS FOR FLOOR PATTERN AND ACCENT

PAINT DETAILS.

5. PROVIDE MOISTURE RESISTANT GYPSUM BOARD WALL

AND CEILING IN ALL RESTROOMS AND JANITOR CLOSETS.

6. PROVIDE VERTICAL AND HORIZONTAL MOVEMENT JOINTS

IN TILE FINISH IAW TILE COUNCIL OF NORTH AMERICA. -

EJ171-09 UNLESS THE TILE MANUFACTURER'S

RECOMMENDED METHOD PROVIDES GREATER

PROTECTION.

7. TILE INSTALLATION SHALL UTILIZE THE FOLLOWING TILE

COUNCIL OF NORTH AMERICA, INC. METHODS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6endrgr\Documents\FY21_PN95039_BLDG315_INT_R21_k6endrgr.rvt

7/20/2021 4:53:37 PM

JU

LY

W

2H N

-2 1-

B-

V.

R

O

BE

R

SO

N

V.

R

O

BE

R

SO

N

S.

B

AR

BI

N A

1-

-1

I-601

IN

TE

R

IO

R U

N

IT

A N

D R

O O

M F

IN

IS

H S

C H

ED

U

LE

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

P.

S

U

LL

IV

AN

READY TO ADVERTISE (RTA)

INTERIOR UNIT FINISH SCHEDULE

ROOM NO ROOM NAME

WALL FINISH BASE FINISH FLOOR CEILING

NOTES & REMARKS (SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FIN. FIN.

01 KITCHEN/DINING PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2, 3, 8

02 BEDROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2

03 CLOSET PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2

04 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6, 9, 10 05 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6, 9, 10

06 BEDROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2

07 CLOSET PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2

08 W/D PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 LVT-1 PT-5 2

09 MECH PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

INTERIOR ROOM FINISH SCHEDULE

ROOM NO ROOM NAME

WALL FINISH BASE FINISH FLOOR CEILING NOTES & REMARKS

(SEE NOTES)NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FIN. FIN.

101 LOBBY PT-2 PT-2 PT-2 PT-2 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

102 RESTROOM CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6 103 JANITOR CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWT-1/CWT-2 CWB-1 CWB-1 CWB-1 CWB-1 PFT-1 PT-5 4, 6

104 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

105 ACTIVITY PT-2 PT-2 PT-2 PT-2 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1, 7

107 MECH EQ &

RISER

PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

108 FA CP PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

109 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

110 TELECOMM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SDT-1 PT-5 5

111 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

112 EQ RM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

113 MECH ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

114 EQ RM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

115 ELECTRICAL PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

116 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

117 MECH ROOM PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

201 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

202 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

203 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

204 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5

205 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5 1

206 STORAGE PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

301 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

302 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

303 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

304 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

305 MECH EQ PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

306 ATTIC ACCESS PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 SEALED CONCRETE PT-5

A1 STAIR PT-3 PT-3 PT-3 PT-3 RB-1 RB-1 RB-1 RB-1 STF-1/STL-1 EXP

A2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

A2/F2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

A3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

A3/F3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

A/F CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

B1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

B2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

B2/E2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

B3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

B3/E3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

B/E CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

C1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

C2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

C2/D2 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

C3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

C3/D3 CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

C/D CORRIDOR PT-1 PT-1 PT-1 PT-1 RB-1 RB-1 RB-1 RB-1 VCT-1 PT-5 1

D1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

D2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

D3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

E1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

E2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

E3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

F1 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

F2 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 EXP

F3 STAIR PT-3 PT-3 PT-3 PT-3 RB-2 RB-2 RB-2 RB-2 STF-1/STL-1 PT-5

SHEET NOTES

GENERAL NOTES

1. WS-1 WINDOW SHADES SHALL BE PROVIDED AT ALL

EXTERIOR WINDOWS, EXCEPTING CURTAIN WALL.

2. REFER TO A-SHEETS FOR LOCATIONS OF CG-1 CORNER

GUARD PLACEMENT.

3. REFERENCE SPECIFICATION SECTION 09 06 00

"SCHEDULE FOR FINISHES" FOR INFORMATION

REGARDING COLOR & FINISH. ALL FINISHES HAVE BEEN

SELECTED AS A BASIS OF DESIGN.

4. ALL INTERIOR COLORS SHALL BE SUBMITTED FOR

APPROVAL PER DIRECTIONS IN SPECIFICATION 09 06 00.

COLOR BOARDS AND PROPOSED SAMPLES SHALL NOT

BE SUBMITTED INDIVIDUALLY BUT IN A COMPLETE SET

WITH ALL SAMPLES.

5. ALL CASEWORK HARDWARE TO BE MANUFACTURED

STANDARD HEAVY DUTY.

6. PAINT ALL SUPPLY & RETURN AIR MECHANICAL GRILLS /

DIFFUSERS ON GWB CEILINGS & WALLS TO MATCH

ADJACENT COLOR.

7. PAINT ALL EXPOSED STRUCTURE TO MATCH ADJACENT

MATERIAL.

8. REFER TO A-SHEETS FOR ALL MILLWORK DETAILS.

REFERENCE SPECIFICATION SECTION 09 06 00

"SCHEDULE FOR FINISHES" FOR ADDITIONAL

INFORMATION REGARDING COLOR AND FINISH.

9. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL

TOILETS, SHOWER AREAS, AND WALLS ADJACENT TO

SINKS.

10. REFER TO SPECIFICATION 03 30 00 CAST-IN-PLACE

CONCRETE FOR FINISH DETAILS.

11. SUBMIT NFPA CLASS RATINGS OF ALL INTERIOR FINISHES

TO QFPE FOR APPROVAL. ALL INTERIOR FINISHES SHALL

COMPLY WITH UFC 3-600-01 AND NFPA 101, CHAPTER 10.

1. VCT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,

CENTERED IN THE CORRIDORS AND ROOMS.

2. LVT-1 PLANKS SHALL BE INSTALLED IN A RANDOM

STAGGER PATTERN. PATTERN SHALL RUN

HORIZONTALLY (PLAN EAST TO WEST) THROUGHOUT THE

UNITS, CENTERED IN THE UNIT KITCHEN.

3. CWT-1 SHALL BE INSTALLED IN A 1/2 OFFSET,

HORIZONTAL RUNNING BOND PATTERN FOR ALL UNIT

KITCHEN BACKSPLASHES. PATTERN SHALL BE CENTERED

OVER THE SINK.

4. REFER TO DETAIL 1 ON SHEET I-502 FOR CWT-1/CWT-2

TYPICAL WALL TILE PATTERN.

5. SDT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,

CENTERED IN THE ROOM.

6. PFT-1 SHALL BE INSTALLED IN A STRAIGHT-LAY PATTERN,

CENTERED IN THE ROOM.

7. PL-1 SHALL BE USED FOR KITCHEN CABINETS IN THE

ACTIVITY ROOM.

8. PL-2 SHALL BE USED FOR KITCHEN CABINETS IN ALL

UNITS.

9. PL-3 SHALL BE USED FOR BATHROOM CABINETS IN ALL

UNITS.

10. SS-2 SHALL BE USED FOR ALL UNIT SHOWER WALLS AND

FLOOR PANS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDKTD\Documents\FY21_PN95039_BLDG315_PLUMB_R21_K6ENDKTD.rvt

7/23/2021 1:07:01 PM

JU

LY

W

2H N

-2 1-

B-

L.

SA

LA

S

L.

SA

LA

S

S.

BA

R

BI

N A

1-

-1

PL601

PL

U

M

BI

N G

S C

H

ED

U

LE

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

K.

D

IX

O

N

READY TO ADVERTISE (RTA)

WCO WALL CLEANOUT WALL CONCURRENT SIZE WITH CONNECTED PIPE, MAX 6"

FCO FLOOR CLEANOUT FLOOR CONCURRENT SIZE WITH CONNECTED PIPE, MAX 6"

P-17 WASHING MACHINE WALL 3/4" 3/4" 1 1/2" 1 1/2"

P-12 MOP SINK FLOOR 1/2" 1/2" 3" 1 1/2" LOCATED IN JANITOR'S CLOSETS, MOP RECEPTOR TYPE, PRE-CAST, TERRAZO.

P-11A WATER COOLER (ADA) WALL 1/2" 1 1/2" 1 1/2" HI/LOW STYLE, PROVIDE WITH INTEGRATED BOTTLE FILLER

P-10 SHOWER WALL 1/2" 1/2" 2" SIDE OUTLET DISCHARGE TYPE

P-7 KITCHEN SINK COUNTER 1/2" 1/2" 1 1/4" 1 1/4"

P-5 LAVATORY COUNTER 1/2" 1/2" 1 1/4" 1 1/4" MANUAL FAUCET

P-4A LAVATORY (ADA) WALL 1/2" 1/2" 1 1/4" 1 1/4" MANUAL FAUCET, PADDLE-TYPE

P-2A WATER CLOSET (ADA) FLOOR 1" 4" 2" FLUSH VALVE, MANUAL DUAL FLUSH

P-1 WATER CLOSET FLOOR 1" 4" 2" FLUSH TANK, MANUAL DUAL FLUSH, WALL EXITING

WH-1 WALL HYDRANT WALL 3/4" FREEZEPROOF

FD-1 FLOOR DRAIN FLOOR 3" 1 1/2" IN MECHANICAL ROOMS PROVIDE TRAP PRIMER, OTHERWISE PROVIDE TRAP GUARD.

MARK DESCRIPTION MOUNTING C.W. (IN) H.W. (IN) WASTE (IN) VENT (IN) NOTES

PLUMBING FIXTURE SCHEDULE

THERMOSTATIC MIXING VALVE SCHEDULE

MARK LOCATION FLOW RATE

(GPM)

COLD E.W.T.

(F)

HOT E.W.T.

(F)

RECIRCULATION E.W.T.

(F)

MIXED L.W.T.

(F)

MAX. PRESSURE DROP

(PSI) NOTES

TMV-1 MECHANICAL ROOM 117 115 GPM 55 °F 140 °F 80 °F 120 °F 5.00 psi

DOMESTIC WATER EXPANSION TANK SCHEDULE

MARK LOCATION

ACCEPTANCE VOLUME

(GAL)

MINIMUM TANK PRE-CHARGE PRESSURE

(PSI)

OPERATING PRESSURE MAX.

(PSI) NOTES

DET-1 MECHANICAL ROOM 117 37.6 70 80 1

HOT WATER GENERATOR SCHEDULE

MARK TYPE

STORAGE

CAPACITY (GAL)

STEAM HOT WATER

NOTES

FLOW

(LB/HR)

PRESSURE

(PSI)

HEATING CAPACITY

(MBH) E.W.T (F) L.W.T. (F)

HWG-1 HOT WATER GENERATOR 940 584 15 551 55 140 1

CIRCULATING PUMP SCHEDULE

MARK SERVICE CAPACITY (GPM) HEAD (FT) HP (MAX) NOTES

DWRP-1 HOT WATER RETURN 5.04 9.5 1/8 IN-LINE BRONZE

NOTES:

1. PRESSURE RELIEF VALVE SHALL BE SET TO 10 PSI ABOVE OPERATING PRESSURE OR 10 PSI BELOW THE MANUFACTURER'S LISTED MAX PRESSURE FOR

THE EQUIPMENT IN THE SYSTEM.

NOTES:

1. PROVIDE VERTICAL JACKETED STORAGE TANK.

2. PROVIDE WITH MANUFACTURER RECOMMENDED PACKAGED CONTROLLER.

3. PROVIDE WITH DOUBLE WALL TUBE BUNDLE.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

JU

L2

PBB

ELECTRICAL

PANEL TR1

12" CABLE

RUNWAY

TELECOM

RACKS

2 - 4" CONDUITS TO

MANHOLE FOR NIPR

TELECOMM

3 - 4" CONDUITS

TO ATTIC

DSS-2

1 - 4" CONDUIT TO

5 FT LINE FOR

PRIVATIZED

TELEPHONE

1' - 6"

SERVICE

PROVIDER

SPACE

EQ RM

CATV

BACKBOARDS

6 EXISTING

CONDUITS

TO ATTIC

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

NORTH ARROW

GENERAL SHEET NOTES

KEY PLAN

PLAN NORTH

C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt

7/26/2021 9:24:59 AM

JU

LY

W

2H N

-2 1-

B-

O . A

N D

ER

SO

N

O . A

N D

ER

SO

N

S.

B

AR

BI

N A

1-

-1

TN401

EN

LA

R G

ED

T

EL

EC

O M

M U

N

IC

AT

IO

N S

PL

AN

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

R . D

AV

IS

READY TO ADVERTISE (RTA)

1/2" = 1'-0"

ENLARGED TELECOMMUNICATIONS ROOM 1101

1/2" = 1'-0"

ENLARGED EQUIPMENT RM 1142

1 PROVIDE FIRE RATED PENETRATIONS THROUGH THE WALL

CONDUITS. COORDINATE FIRE RATING WITH SHEET A003.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

TELECOM

ROOM 110

12 STRAND SM FOC

TO MANHOLE

1ST FLOOR

FIBER

PP IN

RACK

(2) 4-INCH CONDUITS

TO MANHOLE

NOTE 1

TELECOMMUNICATIONS CONDUIT RISER DIAGRAM NOTES:

1. PROVIDE ONE CONDUIT WITH 3-INCH, 3-CELL FABRIC MESH INNERDUCT WITH TRACER WIRE. ALL

EMPTY DUCTS SHALL CONTAIN A PULL STRING. SEE TN501 FOR CONDUIT TYPE.

2. PROVIDE ONE EMPTY CONDUIT FOR PRIVATE TELEPHONE SERVICE PROVIDER. ALL EMPTY DUCTS

SHALL CONTAIN A PULL STRING AND TRACER WIRE. SEE TN501 FOR CONDUIT TYPE.

3. EXISTING TELECOMMUNICATIONS CONDUIT MAY BE REUSED TO THE MAXIMUM EXTENT POSSIBLE.

4. PROVIDE NEW CONDUIT IN SLEEPING UNITS TO EXTEND FROM EXISTING CONDUIT TO NEW

OUTLET LOCATIONS.

5. ALL INTERIOR TELECOMMUNICATIONS CONDUIT SHALL BE EMT UNLESS OTHERWISE NOTED.

TELECOM

ROOM 110

(1) 4-INCH CONDUIT

TO 5-FOOT LINE

NOTE 2

2ND FLOOR

3RD FLOOR

ATTIC

NEW

18" X 18" X 6"

JUNCTION

BOX

NOTE 3

EXISTING

CONDUIT

(TYP)

NOTE 3

NEW

CONDUIT

(TYP)

NOTE 4

1ST FLOOR

2ND FLOOR

3RD FLOOR

ATTIC

1ST FLOOR

C/D WING B/E WING A/F WING

NEW 4"

CONDUIT

(TYP)

TELECOMMUNICATIONS CATV RISER DIAGRAM NOTES:

1. SEE TELECOMMUNICATIONS PLANS FOR LOCATIONS AND QUANTITIES OF CATV OUTLETS.

2. OSP CATV CABLE SHALL BE GFGI.

3. EXISTING CATV BACKBOARDS AND HEAD-END EQUIPMENT SHALL NOT BE DEMOLISHED. CATV CABLING, AND

CONDUIT MAY BE REUSED TO THE MAXIMUM EXTENT POSSIBLE. DEMOLISH ALL CATV OUTLETS.

4. PROVIDE NEW CATV OUTLETS.

2ND FLOOR

TV TV

3RD FLOOR

TV TV

ROOM 114

ATTIC

EXISTING

WIREWAY

TO ATTIC

TVTV

EXISTING

RG-6 (TYP)

NEW CATV

OUTLETS (TYP)

1ST FLOOR

TELECOMMUNICATIONS GROUNDING RISER DIAGRAM NOTES:

1. BOND ALL COMMUNICATIONS EQUIPMENT (BOND RACKS, PROTECTOR MODULES, EQUIPMENT

ENCLOSURES, CABLE TRAYS, AND METALLIC CONDUITS, ETC.) TO THE PBB WITH CONDUCTORS SIZED PER TIA 607-C. EACH BOND SHALL HAVE ITS OWN DEDICATED BONDING CONDUCTOR TO THE PBB.

2. BOND PBB TO NEARBY BUILDING STEEL WITH CONDUCTORS SIZED PER TIA 607-C.

MAIN

NIPR

TR110

1ST FLOOR

BLDG

STEEL

COMM

EQUIP

PANEL

#6 AWG

#1/0 AWG

TO MAIN ELECTRICAL

SERVICE GROUND

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt

7/26/2021 9:25:09 AM

JU

LY

W

2H N

-2 1-

B-

O . A

N D

ER

SO

N

O . A

N D

ER

SO

N

S.

B

AR

BI

N A

1-

-1

TN601

TE

LE

C O

M M

U N

IC

AT

IO

N

S R

IS

ER

D

IA

G R

AM

S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

R . D

AV

IS

READY TO ADVERTISE (RTA)

TELECOMMUNICATIONS FIBER OPTIC RISER DIAGRAM3

TELECOMMUNICATIONS CONDUIT RISER DIAGRAM2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

TELECOMMUNICATIONS CATV RISER DIAGRAM1

TELECOMMUNICATIONS GROUNDING RISER DIAGRAM4

9 8

SERVICE ENTRANCE CONDUITS. SEE TN601 FOR QUANTITIES.

NOT USED

FIBER OPTIC CABLES. SEE TN601 FOR QUANTITIES.

CABLE MANAGEMENT RINGS.

20-FT FIBER MAINTENANCE LOOP.

NOT USED

NOT USED

TELECOMMUNICATIONS PRIMARY BONDING BUSBAR.

QUAD 120 VAC RECEPTACLES, MOUNTED 18" AFF. QUANTITIES AND LOCATIONS PER POWER PLANS.

FIRE-RETARDANT, 3/4" THICK, 8' TALL, WIDTH AS INDICATED ON PLANS, TYPE A/C PLYWOOD BACKBOARD.

PLYWOOD MUST BE APPROVED BY NEC QA/QC BEFORE IT IS INSTALLED. INSTALL PLYWOOD BACKBOARDS WITH THE "A" SIDE FACING OUT AND THE MANUFACTURER'S FIRE-RETARDANT STAMP SHALL BE VISIBLE.

12-PORT (1U), SINGLE-MODE, FIBER OPTIC PATCH PANELS WITH FIBER TRAY AND DUPLEX "LC" CONNECTORS

FOR SERVICE ENTRANCE AND RISER FIBER OPTIC CABLES. QUANTITES AS REQUIRED.

VERTICAL AND FRONT AND REAR HORIZONTAL CABLE WIRE MANAGEMENT, QUANTITIES AS REQUIRED.

LOCAL AREA NETWORK (LAN) ELECTRONICS SHALL BE GFGI. CONTRACTOR SHALL FURNISH AND INSTALL

FIBER OPTIC PATCH CABLES PLUS 25% SPARE.

RACK-MOUNTED, CATEGORY 6, 48-PORT, RJ45 PATCH PANELS FOR COMMERICAL. PATCH PANEL QUANTITIES SHALL BE AS REQUIRED PLUS 25% SPARE FOR FUTURE GROWTH. ALL PORTS SHALL BE POPULATED.

RACK-MOUNTED, CATEGORY 6, 48-PORT, RJ45 PATCH PANELS FOR NIPR. PATCH PANEL QUANTITIES SHALL

BE AS REQUIRED PLUS 25% SPARE FOR FUTURE GROWTH. ALL PORTS SHALL BE POPULATED.

RACK-MOUNTED, UNINTERRUPTIBLE POWER SUPPLY (UPS) SHALL BE GFGI.

RECEPTACLES. TYPES, QUANTITIES, AND MOUNTING INSTRUCTIONS PER POWER SHEETS.

STANDARD, 7-FT, 19-INCH ALUMINUM RACKS. ALL RACKS SHALL HAVE VERTICAL WIRE MANAGEMENT

ASSEMBLIES AND VERTICALLY-MOUNTED RACK GROUNDING BUSBARS INSTALLED.

CABLE RUNWAY. PROVIDE TRANSITION TRAYS TO RACKS SO THAT MINIMUM CABLE BENDING RADII CAN BE

MAINTAINED.

CATEGORY 6 CABLING TO OUTLETS VIA CONDUIT PATHWAYS. OUTLET QUANTITIES AND LOCATIONS PER

TELECOMMUNICATIONS PLANS. SEE TN501 FOR OUTLET DETAILS.

CATEGORY 6 CABLING TO OUTLETS VIA CONDUIT PATHWAYS. OUTLET QUANTITIES AND LOCATIONS PER TELECOMMUNICATIONS PLANS. SEE TN501 FOR OUTLET DETAILS AND TN601 FOR CONDUIT PATHWAYS.

PBB

18 18

TR110 WALL DIAGRAM AND KEYED NOTES:

NOT TO SCALE

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\k6enxoaa\Documents\FY21_PN95039_BLDG315_ELEC_R21_k6enxoaa.rvt

7/26/2021 9:25:19 AM

JU

LY

W

2H N

-2 1-

B-

O . A

N D

ER

SO

N

O . A

N D

ER

SO

N

S.

B

AR

BI

N A

1-

-1

TN602

TE

LE

C O

M M

U N

IC

AT

IO

N

S W

AL

L

D

IA

G

AR

M S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N

N

AH

, G A

FO

R

T G

O R

D O

N , G

EO

R

G

IA

R

EP

AI

R

B

AR

R

AC

K

BU

IL

D

IN

G

FY

, P N

VO

LU

M

E

-B U

IL

D

IN

G

R . D

AV

IS

READY TO ADVERTISE (RTA)

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

J U

L

MAIN TR WALL DIAGRAM AND KEYED NOTES1

SF505 FRAMING DETAILS
A-403 ENLARGED INTERIOR ELEVATION - LIVING UNIT
A-404 ENLARGED INTERIOR ELEVATIONS - SERVICE MODULE
A-603 DOOR SCHEDULE AND TYPES
A-610 ROOM FINISH SCHEDULE
I-601 INTERIOR UNIT AND ROOM FINISH SCHEDULES
PL601 PLUMBING SCHEDULES
TN401 ENLARGED TELECOMMUNICATIONS PLANS
TN601 TELECOMMUNICATIONS RISER DIAGRAMS
TN602 TELECOMMUNICATIONS WALL DIAGARMS