W912HN-19-R-3006_SECTION_G_AMD2.PDF

PDF 4 MB Posted

Attached to
Repair Building 399, Sections A&G, PN90737, Fort Benning, GA
Solicitation number
W912HN19R3006
Issued by

About this file

Drawings Section G Part 1 Amd 2

View the file

Other files

File Type Posted
19R3006vol2.PDF PDF
19R3006vol1.PDF PDF
W912HN-19-R-3006_SECTION_G_AMD5.PDF PDF
W912HN-19-R-3006_SECTION_A_AMD5.PDF PDF
amd5.PDF PDF
19R3006vol1.PDF PDF
amd4.PDF PDF
amd3.PDF PDF
19R3006vol1.PDF PDF
19R3006vol2.PDF PDF
amd2.pdf PDF
W912HN-19-R-3006_SECTION_A_AMD2.PDF PDF
19R3006vol1.PDF PDF
19R3006vol1.pdf PDF
Amd1.pdf PDF
19R3006vol2.PDF PDF
W912HN-19-R-3006_SECTION_A_PART_2.PDF PDF
19R3006vol3.PDF PDF
W912HN-19-R-3006_SECTION_G_PART_1.PDF PDF
W912HN-19-R-3006_SECTION_G_PART_2.PDF PDF
W912HN-19-R-3006_SECTION_A_PART_1.PDF PDF
19R3006vol1.PDF PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING

STUCCO.

WINDOWS AND DOOR IN PENTHOUSE BY OTHER. PROVIDE

CAULK AT PENTHOUSE WINDOWS INSIDE AND OUT.

EXISTING BRICK.NEW WINDOWS,

TYP.

NEW INSULATED

PANEL. TYP.

EL: +0'-0"

EXISTING GAS

METER &

CABINET

EL: +56'-3"

(V.I.F.)

T/ ROOF SLAB

EL: +38'-9"

(V.I.F.)

T/ 4th FLOOR

EL: +26'-3"

(V.I.F.)

T/ 3rd FLOOR

EL: +13'-9"

(V.I.F.)

T/ 2nd FLOOR

T/ 1st FLOOR

EXISTING

STUCCO.

NEW WINDOWS, TYP.

WINDOWS AND DOOR IN PENTHOUSE. PROVIDE

CAULK AT PENTHOUSE WINDOWS INSIDE AND OUT.

EXISTING

BRICK.

NEW INSULATED

PANEL. TYP.

BALCONY ELEVATION

SCALE: 1/8" = 1'-0"1

A-203

A R

C H

IT

E

C T

U R

A L

E X

T E

R

IO

R E

L E

V A

T

IO

N S

W G

A M

B L E

C

P

IT

T S

P

Z

IN

N I

G B

E N

A -2

.D

W G

BALCONY ELEVATION

SCALE: 1/8" = 1'-0"2

GENERAL NOTES:

1. PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD-VERIFY AND DOCUMENT EXISTING

SIZE, DIMENSIONS, CONFIGURATION, STYLE, COLOR, PROFILE AND FENESTRATION

DETAILING OF EACH INDIVIDUAL EXTERIOR WINDOW TO BE REPLACED. PROVIDE NEW

WINDOWS TO MATCH THESE CHARACTERISTICS AND MAINTAIN THE HISTORICAL

INTEGRITY OF THE EXISTING BUILDING. NEW WINDOWS SHALL ALSO CONFORM TO THE

REQUIREMENTS LISTED BELOW AND IN THE SPECIFICATIONS AND TO MATCH NEW

FOURTH FLOOR TOWER WINDOWS PROVIDED BY OTHER.

2. NEW EXTERIOR WINDOWS SHALL ASSEMBLIES COMPRISED OF PREFINISHED

ALUMINUM FRAMES WITH INSULATING LOW-E GLASS. GLAZING SHALL CONSIST OF

TWO (2) 1/8" LAMINATED ANNEALED GLASS PANELS WITH PVB 0.030" INTERLAYER AT

INTERIOR SIDE, 1/2" AIR SPACE, AND 1/4" ANNEALED GLASS.

3. PANEL AT THE EXTERIOR SIDE. EACH OPENING IS TAGGED WITH WINDOW TYPE ON

PLANS. SEE A-611 FOR LISTING OF ALL WINDOW TYPES. SEE PLANS AND WINDOW

TYPES FOR LOCATIONS WHERE SPANDREL GLASS PANELS OR INSULATED OPAQUE

PANELS ARE REQUIRED INSTEAD OF STANDARD GLAZING.

4. NEW EXTERIOR WINDOWS SHALL MEET UFC-4-010-01 DOD MINIMUM ANTI-TERRORISM

STANDARDS FOR BUILDINGS.

5. INFILL AND BRICK UP OPENINGS LEFT BY REMOVAL OF VENTS TO MATCH ADJACENT

CONSTRUCTION.

6. PATCH AND PAINT EXISTING STUCCO EXTERIOR WALL FINISH AT LOCATIONS AS

INDICATED. REPAIR AS REQ'D. SEE SPEC SECTION 09 90 00.

7. REPAIR MASONRY WALL DAMAGE, CRACKING, AND SPALLING AS REQ'D. CLEAN,

PATCH, REPAIR, AND RE-TUCKPOINT EXISTING BRICK AND STONE TRIM AT LOCATIONS

AS INDICATED. APPLY CLEAR ANTI-GRAFFITI COATING.

8. ALL EXTERIOR PAINTED SURFACES TO HAVE EXISTING PAINT REMOVED, THE SURFACE

PREPARED AND A NEW PAINT SYSTEM APPLIED. THIS INCLUDES, BUT IS NOT LIMITED

TO, CURRENTLY PAINTED STUCCO, PAINTED CONCRETE, WOOD TRIM, RAILINGS,

STORAGE BUILDINGS AND THEIR DOORS. NOTE THAT REMOVAL AND DISPOSAL OF ALL

LEAD BASED PAINT IS IN THE SCOPE OF THIS CONTRACT. REMOVE SIGNS AND ANY

OTHER ITEM OBSTRUCTING ACCESS TO THE ENTIRE PAINTED SURFACE AND

REINSTALL AT THE COMPLETION OF WORK.

9. CLAY TILE ROOF BY OTHER. ROOF WORK REQUIRED FOR ALL PENETRATIONS

THROUGH THE ROOF REQUIRED BY THIS CONTRACT ARE THE RESPONSIBILITY OF THIS

CONTRACT. ROOF WORK COMPLETED UNDER THIS CONTRACT SHALL IN NO WAY VOID

THE ROOF WARRANTY AND GUARANTY.

10. COOPER GUTTERS AND DOWNSPOUTS TO RECEPTORS BY OTHER. REMOVAL AND

REPLACEMENT OF GUTTERS AND/OR DOWNSPOUTS REQUIRED TO COMPLETE

PAINTING SHALL IN NO WAY VOID THE GUTTER SYSTEM WARRANTY AND GUARANTEE.

11. CONFIRM LOCATIONS OF LIGHTNING PROTECTION SYSTEM COMPONENTS. ANY

REMOVAL / REPLACEMENT OF LIGHTING SYSTEM COMPONENTS REQUIRED TO

COMPLETE THE WORK OF THIS CONTRACT MUST BE COMPLETED BY CONTRACTOR

ISSUING THE UL CERTIFICATION OF THE LIGHTNING PROTECTION SYSTEM.

12. EXISTING STORAGE BUILDINGS TO REMAIN. EXISTING STORAGE BUILDING DOORS,

FRAMES, AND HARDWARE TO REMAIN. CLEAN, REPAIR, AND PAINT.

13. CLEAN, PATCH, AND RE-COAT ALL EXISTING STUCCO. REPAIR AS REQ'D.

EXTERIOR COLORED SURFACES:

N. COLOR SHALL MATCH EXISTING. SUBMIT SAMPLES INCLUDING BOTH:

A FABRICATED PORTION OF UNIT OF WORK AND COLOR SAMPLES TO

OWNER/ARCHITECT.

A N

S I D

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

SHEET ID

ISSUED FOR CONSTRUCTION

F

IL

E N

A M

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

S O

L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

A

M A

R K

S

IZ

E

S U

B M

IT

T

E D

B Y

D A

T E

C O

N T

R A

C T

N O

US Army Corps of Engineers

C A

T E

G O

R Y

C O

D E

D E

S C

R

IP

T

IO

N

M

IC

H

IG

A

N A

V E

S

U

IT

E

C H

IC

A

G O

IL

T :3

.6

.7 w w w .e x p fe d e ra l.

c o m p ro j n o

C H

I-

-A

D E

S

IG

N R

E P

A

IR

O F

O L S

O N

H A

L L

B U

IL

D

IN

G

S E

C T

IO

N

G F

O R

T B

E N

N

IN

G

G A

M A

Y

W

H N

-1

-R -3

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L

E T

H O

R P

E A

V E

S A

V A

N N

A H

G

A

KEY NOTES FOR NEW WORKS ON EXTERIOR

A. REPAIR BRICK VENEER CRACK AT CONC. BEAM

B. REPAIR EXPOSED CONCRETE COLUMN REBAR. SEE 8/S-501 FOR

DETAIL.

SEE GENERAL NOTES ON A200 SERIES SHEETS FOR DETAILS OF REPAIR.

B

AA

B

R E

V

IS

E D

I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/3

/2

A-201 EXTERIOR ELEVATIONS - COURTYARD SIDE
A-202 EXTERIOR ELEVATIONS
A-203 EXTERIOR ELEVATIONS

File details come from the government source that posted it.