W912HN19Q5019 Upper Dissolved Oxygen Diffuser Remediation Questions and Answers
Q. What the typical range of current (maximum and minimum) is at the Upriver DO site?
A. 1f/s=.59 kts
For the last few months:
Most readings have been around .8 kts
The max has been 1.5 kts
The min has been .8 kts
File details come from the government source that posted it.