Attachment 4. Required Specifications Updated 23 JAN 2025.docx
DOCX document 20 KB Posted
- Attached to
- Storage Boxes
- Solicitation number
- W912GY-25-Q-0008
About this file
This specifications document details the requirements for double-walled corrugated storage boxes for Sierra Army Depot in Herlong, CA. The boxes must be made of double-walled corrugated fiberboard manufactured to ASTM-D5118 standards, with glued construction, flutes perpendicular to the scoreline, and contain at least 25% postconsumer or recovered fiber. The boxes must meet specific ASTM D4727 requirements for Weather-Resistant (WR) construction with specified bursting strengths of 600 (dry) or 300 (wet), and use Full Overlap Slotted design.
Three different box sizes are required: CLIN 0001 (36"x9"x28"), CLIN 0002 (36.5"x10"x19"), and CLIN 0003 (26.5"x20"x9"). The procurement is being conducted as a small business set-aside under NAICS code 322211 with a size standard of 1,250 employees, using Simplified Acquisition Procedures. The Department of the Army Materiel Command Contracting Command Detroit Arsenal (ACC Warren) will award one firm-fixed-price contract for this requirement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions and Answers Updated 23 JAN 2025 - W912GY-25-Q-0008.docx | DOCX document | |
| RFQ Amendment 0001_W912GY25Q0008_23 JAN 2025.pdf | ||
| RFQ_W912GY25Q0008_15 JAN 2025.pdf | ||
| Questions and Answers - W912GY-25-Q-0008.docx | DOCX document | |
| Attachment 3. Army Contract Writing System (ACWS) Transition Information for Offerors.docx | DOCX document | |
| Attachment 4. Required Specifications.docx | DOCX document | |
| RFQ_W912GY25Q0008_15 JAN 2024.pdf | ||
| Attachment 1. Addendum to 52.212-1.docx | DOCX document | |
| Attachment 2. Local Narratives.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Required Specifications for Storage Boxes
1. All storage boxes shall be:
a. Made of double-walled corrugated fiberboard, manufactured in accordance with ASTM-D5118.
b. Glued together, not stapled.
c. Made with the flutes perpendicular to the scoreline of box opening.
d. At least 25% postconsumer fiber or total recovered fiber by weight, in accordance with the EPA Comprehensive Procurement Guideline program.
e. In accordance with ASTM D4727 CF (Corrugated Fiberboard), Weather-Resistant (WR), DW (Double Wall) V11c Box shall have a Combined Weight of Facings of 270 (lb/1000 ft2) and a Bursting Strength of (DRY) 600 or (WET) 300.
f. In accordance with ASTM D4727 Type CF (Corrugated Fiberboard) for DW boxes is either (WR) and Weather Resistant/Fire Retardant (WR/FR), and Water and Water Vapor Resistant Classes (WWVR). The requirement shall be Weather-Resistant (WR) and the inner facing shall be the same thickness as the outer facing. Cold adhesive shall conform to CID-A-A-59692 which is water-resistant.
g. The boxes shall be made in the Full Overlap Slotted design (FOL/0203, in accordance with 6.2.2.3 of ASTM D5118, except that the width of the outer flaps shall be the full width of the box and shall not extend beyond the edge of the box (see 6.6)).
2. Required dimensions for CLIN 0001: 36 in. x 9 in. x 28 in. (L x W x H)
3. Required dimensions for CLIN 0002: 36.5 in. x 10 in. x 19 in. (L x W x H)
4. Required dimensions for CLIN 0003: 26.5 in. x 20 in. x 9 in. (L x W x H)
File details come from the government source that posted it. Updated .