This document is an attachment that outlines the salient characteristics for an X-Ray Inspection System required by the Department of the Army Materiel Command Contracting Command Detroit Arsenal. The system must have a minimum tunnel size of 59 inches wide by 70.9 inches high, a conveyor belt capable of handling at least 2,646 lbs, the ability to connect to external monitors, and image recall functionality to display at least 10 previously scanned objects. Technically, the system must have a minimum steel penetration of 28 mm, a wire resolution of at least 38 AWG, a 100% duty cycle X-Ray generator, and radiation leakage less than 0.5 mR per hour. This requirement is being solicited as a small business set-aside under Solicitation Number W912GY25Q0005, with a North American Industrial Classification Code (NAICS) of 334519 and a business size standard of 600 employees.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics for X-Ray Inspection System

General

· Tunnel Size: Must be able to scan objects up to 59 inches x 70.9 inches (W x H)

· Conveyer: Pulling weight must be no less than 1200 kg (2,646 lbs) and belt movement must be bidirectional (forward and reverse)

· Operating System: Must be able to connect to external monitors via HDMI cable. Must contain an image recall function that can show at least 10 previously scanned objects. Must include controls for belt movement with options to stop, move forward and backward.

· System Power: 220 VAC +/- 10%

Technical

· Steel Penetration: Must be at least 28 mm

· Wire Resolution: Must be at least 38 AWG

X-Ray Generator

· Duty Cycle: 100%

· Dose per Exam: Must be less than 0.1 mR per hour

· Radiation Leakage: Must be less than 0.5 mR per hour

File details come from the government source that posted it. Updated .