03-W9123617D0001 Final RAS-SITE_CAL.pdf

PDF 752 KB Posted

Attached to
Rygge DABS / FEV New Construction
Solicitation number
W912GB26RA013
Issued by

About this file

This document is a set of architectural and engineering design drawings for a construction project at Rygge Air Station in Norway. The contract is identified as W912GB-19-D-0015, issued by the U.S. Army Corps of Engineers Europe District on October 30, 2026, for the construction of ECAOS DABS-FEV/EMEDS Storage facilities. The drawings constitute the Final Design Submission and include both mechanical and electrical site plans organized into five distinct areas.

The mechanical plans (sheets MS101-MS106) depict site-wide utility infrastructure including geothermal well systems (300 meters deep, 600 millimeters in diameter), ground water supply and return lines (ranging from 40 to 200 millimeters), hot water supply and return lines, chilled water supply and return lines, and fuel oil supply lines. Key facilities served include RAS AB (Rolling Stock), RAS C (Pallet Storage), RAS D (Container Storage), RAS E (Fuel Vehicle Facility), RAS G (Vehicle Maintenance), RAS H (Central Plant), RAS K (Secure Entry), and RAS L (Pump House). The electrical plans (sheets ES101-ES106) show medium-voltage and low-voltage distribution systems, including switchgear installations (MV-SWGR-01 through MV-SWGR-06), fused disconnect switches ranging from 250 to 2500 amperes, direct-buried power cables, and conduit routing. All utilities are designed in accordance with host nation requirements, with handholes and manholes specified as traffic-rated. The design was prepared by WSP located in Virginia Beach, Virginia, under the direction of J. Flynn (designer), J. Scott (drawn by), T. Newswanger (checked by), and R. Maslyn (submitted by).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AREA 01 AREA 02 AREA 03 AREA 04

AREA 05

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

75 m

1:1500

SCALE

SEAL - SEGL

MS101

RAS-SITE

O

VE

R

AL

L

SI

TE

M

EC

H

AN

IC

AL

P

LA

N

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

1 : 1500

OVERALL SITE MECHANICAL PLAN

PLAN

NORTH

1. REFER TO DETAIL A1 ON CU501 FOR DETAILING ON HOW

MECHANICAL PIPING WILL BE BURIED.

2. REFER TO THE CU SERIES DRAWINGS FOR FULL UTILITY PLAN

LAYOUTS. PIPING LAYOUT SHOWN IS ONLY DIAGRAMMATIC TO

SHOW DESIGN INTENT.

3. REFER TO SITE PACKAGE, CU141 THROUGH CU144 FOR

GEOTHERMAL WELL COORDINATES. GEOTHERMAL WELLS

SHALL BE 300 M DEEP AND 600 MM IN DIAMETER.

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 RAS AB - ROLLING STOCK

2 RAS C - PALLET STORAGE

3 RAS G - VEHICLE MAINTENANCE

4 RAS H - CENTRAL PLANT

5 RAS L - PUMP HOUSE

6 RAS D - CONTAINER STORAGE

7 RAS E - FUEL VEHICLE FACILITY

8 RAS K - SECURE ENTRY

50 GWS

FT

M

AT

C

H

LI

N E

A1 M

S1

50 GWS

40 GWS

150 GWR

50 HWS/R

50 CHWS/R

50 FOR

50 FOS

RAS-A-B

ROLLING

STOCK

RAS-G

VEHICLE

MAINTENANCE

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

20 m

1:400

SCALE

SEAL - SEGL

MS102

RAS-SITE

SI

TE

M

EC

H

AN

IC

AL

P

LA

N A

R

EA

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE MECHANICAL PLAN AREA 01

1. REFER TO DETAIL A1 ON CU501 FOR DETAILING ON HOW

MECHANICAL PIPING WILL BE BURIED.

2. REFER TO THE CU SERIES DRAWINGS FOR FULL UTILITY PLAN

LAYOUTS. PIPING LAYOUT SHOWN IS ONLY DIAGRAMMATIC TO

SHOW DESIGN INTENT.

3. REFER TO SITE PACKAGE, CU141 THROUGH CU144 FOR

GEOTHERMAL WELL COORDINATES. GEOTHERMAL WELLS

SHALL BE 300 M DEEP AND 600 MM IN DIAMETER.

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 SEE SHEET MP401 IN RAS-A-B FOR MECHANICAL PIPING

PENETRATIONS INTO BUILDING.

2 SEE RAS-G MP101 FOR CONTINUATION

M

AT

C

H

LI

N E

A1 M

S1

M

AT

C

H

LI

N E

A1 M

S1

80 GWS 100 GWS

100 GWS

80 GWS

50 GWS 100 GWR 80 GWR

150 GWR

100 HWS/R

80 HWS/R

80 HWS/R

80 HWS/R

80 HWS/R

50 HWS/R

100 CHWS/R

65 CHWS/R

80 CHWS/R

80 CHWS/R

80 CHWS/R

50 CHWS/R

RAS-A-B

ROLLING STOCK

RAS-G

VEHICLE MAINTENANCE

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

20 m

1:400

SCALE

SEAL - SEGL

MS103

RAS-SITE

SI

TE

M

EC

H

AN

IC

AL

P

LA

N A

R

EA

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE MECHANICAL PLAN AREA 02

1. REFER TO DETAIL A1 ON CU501 FOR DETAILING ON HOW

MECHANICAL PIPING WILL BE BURIED.

2. REFER TO THE CU SERIES DRAWINGS FOR FULL UTILITY PLAN

LAYOUTS. PIPING LAYOUT SHOWN IS ONLY DIAGRAMMATIC TO

SHOW DESIGN INTENT.

3. REFER TO SITE PACKAGE, CU141 THROUGH CU144 FOR

GEOTHERMAL WELL COORDINATES. GEOTHERMAL WELLS

SHALL BE 300 M DEEP AND 600 MM IN DIAMETER.

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 SEE SHEET MP401 IN RAS-G FOR MECHANICAL PIPING

PENETRATIONS INTO BUILDING.

2 SEE SHEET MP402 IN RAS-A-B FOR MECHANICAL PIPING

MS401

A1

150 GWS

M

AT

C

H

LI

N E

A1 M

S1

M

AT

C

H

LI

N E

A1 M

S1

100 GWS

40 GWR50 GWR80 GWR 50 GWR

150 GWS

140 GWR, ENTIRE

LENGTH OF REVERSE

RETURN LINE

100 GWS

100 GWS

40 GWR

50 GWR

80 GWR

100 GWR, ENTIRE

LENGTH OF REVERSE

RETURN LINE

100 GWS

200 GWS/R

HEADER

100 GWS

80 GWS

40 GWR

50 GWR

50 GWR

100 GWR, ENTIRE

LENGTH OF REVERSE

RETURN LINE

150 HWS/R

50 HWS/R

150 HWS/R

100 HWS/R

100 HWS/R

80 HWS/R

100 CHWS/R

40 CHWS/R

100 CHWS/R

65 CHWS/R

100 CHWS/R

100 CHWS/R

GSHP LOOP SHUTOFF

VALVES.

RAS-E

FUEL VEHICLE FACILITY

RAS-A-B

ROLLING STOCK

RAS-H

CENTRAL PLANT

PURGE VALVE PIT, SEE

GENERAL CONSTRUCTION

PACKAGE A9/M-507

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

20 m

1:400

SCALE

SEAL - SEGL

MS104

RAS-SITE

SI

TE

M

EC

H

AN

IC

AL

P

LA

N A

R

EA

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE MECHANICAL PLAN AREA 03

1. REFER TO DETAIL A1 ON CU501 FOR TRENCHING DETAIL.

2. REFER TO CIVIL CU SERIES CONTRACT DRAWINGS FOR FULL

UTILITY PLAN LAYOUTS; CONTRACTOR SHALL COORDINATE

INSTALLATION OF ALL MATERIALS.

3. GEOTHERMAL BORE HOLES SHALL BE SPACED 15 M APART,

MINIMUM.

4. REFER TO SITE PACKAGE, CU141 THROUGH CU144 FOR

GEOTHERMAL WELL COORDINATES. GEOTHERMAL WELLS

SHALL BE 300 M DEEP AND 600 MM IN DIAMETER.

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 SEE SHEET MP401 IN RAS-H FOR MECHANICAL PIPING

2 SEE RAS-A-B MP401 FOR CONTINUATION

M

AT

C

H

LI

N E

A1 M

S1

M

AT

C

H

LI

N E

A1 M

S1

40 GWS

50 GWS50 GWS

80 GWS

80 GWS

80 GWR

100 GWR

100 GWR80 GWR

80 GWS

80 GWS 50 GWS

50 GWS

40 GWS

100 GWR

50 GWR 80 GWR 100 GWR

80 GWR

80 HWS/R

50 HWS/R

50 HWS/R

50 HWS/R

65 CHWS/R

50 CHWS/R

50 CHWS/R

50 CHWS/R

RAS-C

PALLET STORAGE

RAS-D

CONTAINER STORAGE

RAS-E

FUEL

VEHICLE

FACILITY

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

20 m

1:400

SCALE

SEAL - SEGL

MS105

RAS-SITE

SI

TE

M

EC

H

AN

IC

AL

P

LA

N A

R

EA

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE MECHANICAL PLAN AREA 04

1. REFER TO DETAIL A1 ON CU501 FOR DETAILING ON HOW

MECHANICAL PIPING WILL BE BURIED.

2. REFER TO THE CU SERIES DRAWINGS FOR FULL UTILITY PLAN

LAYOUTS. PIPING LAYOUT SHOWN IS ONLY DIAGRAMMATIC TO

SHOW DESIGN INTENT.

3. REFER TO SITE PACKAGE, CU141 THROUGH CU144 FOR

GEOTHERMAL WELL COORDINATES. GEOTHERMAL WELLS

SHALL BE 300 M DEEP AND 600 MM IN DIAMETER.

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 SEE SHEET MP401 IN RAS-D FOR MECHANICAL PIPING

2 SEE RAS-C MP401 FOR CONTINUATION

M

AT

C

H

LI

N E

A1 M

S1

RAS-C

PALLET STORAGE

RAS-L

PUMP HOUSE

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

EU

R O

PE

D

IS

TR

IC

T

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

P

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

20 m

1:400

SCALE

SEAL - SEGL

MS106

RAS-SITE

SI

TE

M

EC

H

AN

IC

AL

P

LA

N A

R

EA

O

VE

R

SI

KT

SP

LA

N V

EN

TI

LA

SJ

O N

P

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

J.

F

LY

N

N

J.

S

C O

TT

R . M

AS

LY

N

T.

N

EW

SW

AN

G

ER

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE MECHANICAL PLAN AREA 05

1. NO SITE MECHANICAL WORK IN THIS AREA. AREA IS SHOWN

FOR REFERENCE ONLY.

AREA 01 AREA 02 AREA 03 AREA 04 AREA 05

3 4

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

75 m

1:1500

SCALE ES101

RAS-SITE

O

VE

R

AL

L

SI

TE

E

LE

C

TR

IC

AL

P

LA

N

EL

E

KT

R O

U

TO

M H

U

SP

LA

N

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R . M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

1 : 1500

OVERALL SITE ELECTRICAL PLAN - UTENOMHUS ELEKTRO PLAN

PLAN

NORTH

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 RAS AB - ROLLING STOCK

2 RAS G - VEHICLE MAINTENANCE

3 RAS H - CENTRAL PLANT

4 RAS E - FUEL VEHICLE FACILITY

5 RAS D - CONTAINER STORAGE

6 RAS C - PALLET STORAGE

7 WATER STORAGE TANK

8 RAS L - PUMP HOUSE

9 RAS K - SECURE ENTRY

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E R

10-30-2026

LV-

EHH-52

LV-EHH-53

LV-

EHH-54

BUILDING K

SECURE ENTRY

CIRCUITS

PULLBOX

2-50MM CONDUITS

2-50MM

CONDUITS

2-50MM

CONDUITS

RAS-A-B

ROLLING

STOCK

RAS-G

VEHICLE

MAINTENANCE

M

AT

C

H

LI

N E

A1

ES

LV-EHH-55

BUILDING K

SECURE ENTRY

SLIDING GATESLIDING GATE

POWER & CONTROL

CONNECTION TO

SLIDING GATE

4-50MM

CONDUITS

2-50MM

CONDUITS

2-50MM

CONDUITS

800KW, 4160V

LOAD BANK.

3-95 MM2, 5KV AND 1-16

MM2 600V CONDUCTORS

IN 103MM CONDUIT TO

LOAD BANK QUICK

CONNECT SWITCHGEAR.

SEE SHEET RAS-G EP101.

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

AREA 02AREA

AREA

AREA 03 AREA 04

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

20 m

1:400

SCALE ES102

RAS-SITE

SI

TE

E

LE

C

TR

IC

AL

P

LA

N A

R

EA

-E

LE

KT

R

O U

TO

M

H U

SP

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R . M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

1 : 400A1 SITE ELECTRICAL PLAN AREA 01 - UTENOMHUS ELEKTRO PLAN DEL 01

PLAN

NORTH

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E

AREA 02AREA

AREA

AREA 03 AREA 04

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

MANHOLE VALVE

ACCESS LOCATION MANHOLE VALVE

ACCESS LOCATION

NG-DP

PGCC-RAS-G

MTS-RAS-G

2 SETS OF 3-120MM2 17.5KV MV-105

CABLES DIRECT BURIED WITH EACH

SET IN TREFOIL ARRANGEMENT

RAS-A-B

ROLLING STOCK

RAS-G

VEHICLE MAINTENANCE

T-RAS-G

2 SET OF 3-120MM2 17.5KV

MV-105 CABLES DIRECT BURIED

IN TREFOIL ARRANGEMENT

M

AT

C

H

LI

N E

A1

ES

M

AT

C

H

LI

N E

A1

ES

B9 E-506

J1 E-510

FUSED DISCONNECT

SWITCH 800A/800A/3P

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

20 m

1:400

SCALE ES103

RAS-SITE

SI

TE

E

LE

C

TR

IC

AL

P

LA

N A

R

EA

-E

LE

KT

R

O U

TO

M

H U

SP

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R . M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE ELECTRICAL PLAN AREA 02 - UTENOMHUS ELEKTRO PLAN DEL 02

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E

AREA

AREA 03 AREA 04

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

NAB-DP

NE-DP

PGCC-RAS-AB

MTS-RAS-AB

T-RAS-E

MTS-RAS-E

PGCC-E

RAS-E

FUEL VEHICLE FACILITY

RAS-A-B

ROLLING STOCK

RAS-H

CENTRAL

PLANT

T-RAS-A-B

PGCC-H

M

AT

C

H

LI

N E

A1

ES

M

AT

C

H

LI

N E

A1

ES

FUEL

OFFLOADING

FUEL

TANK

FUEL CONTAINMENT

FUELING

ISLAND

J1 E-510

J1 E-510

J9 E-510

J1 E-510

B9 E-506

B9 E-506

ES401

A1

J9 E-510

MEDIUM VOLTAGE

SWITCHGEAR

MV-SWGR-02

T-RAS-H

J9 E-510

MEDIUM VOLTAGE

SWITCHGEAR

MV-SWGR-01

MTS-RAS-H

NH-DP

J1 E-510

G1 E-508

J9 E-510

J9 E-510

FUSED DISCONNECT

SWITCH 1000A/1000A/3P

FUSED DISCONNECT

SWITCH 400A/400A/3P

FUSED

DISCONNECT

SWITCH

2500A/2500A/3P

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

20 m

1:400

SCALE ES104

RAS-SITE

SI

TE

E

LE

C

TR

IC

AL

P

LA

N A

R

EA

-E

LE

KT

R

O U

TO

M

H U

SP

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R .M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE ELECTRICAL PLAN AREA 03- UTENOMHUS ELEKTRO PLAN DEL 03

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E

AREA

AREA 03 AREA 04

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

EXISTING 'K21'

SUBSTATION

ND-DP

NC-DP

T-RAS-C

PGCC-D

MTS-RAS-C

PGCC-C

MTS-RAS-D

RAS-C

PALLET STORAGE

RAS-D

CONTAINER STORAGE

RAS-E

FUEL

VEHICLE

FACILITY

MEDIUM VOLTAGE

SWITCHGEAR

MV-SWGR-03

T-RAS-D

M

AT

C

H

LI

N E

A1

ES

M

AT

C

H

LI

N E

A1

ES

J1 E-510

J1 E-510

J9 E-510

J9 E-510

J9 E-510

B9 E-506

J9 E-510

FUSED DISCONNECT

SWITCH 400A/400A/3P FUSED DISCONNECT

SWITCH 250A/250A/3P

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

20 m

1:400

SCALE ES105

RAS-SITE

SI

TE

E

LE

C

TR

IC

AL

P

LA

N A

R

EA

-E

LE

KT

R

O U

TO

M

H U

SP

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R .M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE ELECTRICAL PLAN AREA 04- UTENOMHUS ELEKTRO PLAN DEL 04

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E

AREA

AREA 03 AREA 04

1. ALL MANHOLES AND HANDHOLES SHALL BE TRAFFIC RATED.

2. ALL LOW-VOLTAGE ELECTRIC HANDHOLES ARE 1200MM X

1200MM X 1200MM HIGH INSIDE DIMENSIONS AND WALL

THICKNESS IS MINIMUM 200MM.

3. ALL MEDIUM-VOLTAGE MANHOLES ARE 2800MM X 3700MM X

2000MM HIGH INSIDE DIMENSIONS AND WALL THICKNESS IS

MINIMUM 200MM.

4. ALL MEDIUM-VOLTAGE POWER DISTRIBUTION CABLES SHALL

BE DIRECT BURIED AND INSTALLED IN ACCORDANCE WITH

HOST NATION REQUIREMENTS.

5. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL GENERAL NOTES, ABBREVIATIONS AND

LEGEND.

6. REFER TO ELECTRICAL GENERAL CONSTRUCTION PACKAGE

FOR ELECTRICAL DETAILS.

MEDIUM VOLTAGE

SWITCHGEAR MV-SWGR-06

PGCC-L

NL-DP

MTS-RAS-L

FP-2

CONTROLLER

RAS-C

PALLET STORAGE

RAS-L PUMP HOUSE

T-RAS-FP-1

T-RAS-L

M

AT

C

H

LI

N E

A1

ES

J9 E-510

MEDIUM VOLTAGE

SWITCHGEAR MV-SWGR-05

MEDIUM VOLTAGE

SWITCHGEAR MV-SWGR-04

T-RAS-FP-2

T-RAS-FP-3

T-RAS-FP-4

FP-1

CONTROLLER

MV-EMH-01

MV-EMH-02

FUTURE

"K/YX"

SUBSTATION

G11 E-508 1

ES402

A1

FUSED DISCONNECT

SWITCH 250A/250A/3P

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W

N B

Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

O

N

M

L

K

J

H

G

F

E

D

C

B

A

GRAPHIC SCALES -

SKALA

SHEET NOTES - HENVISNINGER

KEY PLAN - LOKALISERINGSFIGUR

SEAL - SEGL

NOT FOR

CONSTRUCTIO

N

20 m

1:400

SCALE ES106

RAS-SITE

SI

TE

E

LE

C

TR

IC

AL

P

LA

N A

R

EA

-E

LE

KT

R

O U

TO

M

H U

SP

LA

N D

EL

R

YG

G E

AI

R

S

TA

TI

O

N , N

O R

W

AY

EU

R

O

PE

D

IS

TR

IC

T

W

SP

BE

N

D

IX

R D

S

TE

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

B.

IN

YA

M

A

T.

S

H

IU

R . M

AS

LY

N

N . A

H O

U N

O U

O C

TO

BE

R

0, W

2G B-

-D

-0

C O

N

ST

R U

C T

EC

AO

S D

AB

S-

FE

V/

EM

ED

S

ST

O R

AG

E

O C

TO

BE

R

0, FI

N

AL

D

ES

IG

N S

U

BM

IS

SI

O N

PLAN

NORTH

1 : 400A1 SITE ELECTRICAL PLAN AREA 05- UTENOMHUS ELEKTRO PLAN DEL 05

APPLIES TO THIS SHEET ONLY

KEYNOTES

MARK DESCRIPTION

1 CAP CONDUITS AT 1000MM PAST THE EDGE OF THE ROADWAY.

2 SUBSTATION “K/YX” IS TO BE FURNISHED BY THE POWER

UTILITY. THE SHOWN LOCATION IS PRELIMINARY. VERIFY AND

FINALIZE THE SUBSTATION LOCATION AND ALL SERVICE

CONNECTION REQUIREMENTS DIRECTLY WITH THE POWER

UTILITY.

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

NOT FOR

CONSTRUCTIO

N

DMITRI ZAICHENKO

M C

O M

O N

W

EALTH OF

V

IR

G I N I A

O

N

E

NS

F E S

AION L E

G I

Lic. No. 042517

P R

E

Life Safety
GS101 - OVERALL SITE CODE COMPLIANCE PLAN -OVERORDNET PLAN FOR FORSKRIFT OVERENSSTEMMELSE
Mechanical
MS101 - OVERALL SITE MECHANICAL PLAN -OVERSIKTSPLAN VENTILASJON PLAN
MS102 - SITE MECHANICAL PLAN AREA 01 -OVERSIKTSPLAN VENTILASJON PLAN DEL 01
MS103 - SITE MECHANICAL PLAN AREA 02 -OVERSIKTSPLAN VENTILASJON PLAN DEL 02
MS104 - SITE MECHANICAL PLAN AREA 03 -OVERSIKTSPLAN VENTILASJON PLAN DEL 03
MS105 - SITE MECHANICAL PLAN AREA 04 -OVERSIKTSPLAN VENTILASJON PLAN DEL 04
MS106 - SITE MECHANICAL PLAN AREA 05 -OVERSIKTSPLAN VENTILASJON PLAN DEL 05
MS301 - ABOVE GROUND STORAGE TANK PIPING SECTION -SNITT RØROPPLEGG LAGERTANK OVER BAKKEN
MS302 - ABOVE GROUND STORAGE TANK PIPING SECTION -SNITT RØROPPLEGG LAGERTANK OVER BAKKEN
MS401 - ABOVE GROUND STORAGE TANK PIPING DIAGRAM -DIAGRAM RØROPPLEGG LAGERTANK OVER BAKKEN
MS402 - ABOVE GROUND STORAGE TANKS OFFLOAD PAD PIPING PLAN -AVLASTNINGSOMRÅDE PLAN RØR LAGERTANK OVER BAKKEN
MS403 - ABOVE GROUND STORAGE TANK PIPING DIAGRAM -DIAGRAM RØROPPLEGG LAGERTANK OVER BAKKEN
MS901 - ABOVE GROUND STORAGE TANKS FUEL SYSTEM DIAGRAM -DIAGRAM BRENSELSYSTEM LAGERTANK OVER BAKKEN
MS902 - FUEL SYSTEMS DISPENSER FLOW DIAGRAM -BRENSELSYSTEM FORDELING FLYTDIAGRAM
Electrical
ES101 - OVERALL SITE ELECTRICAL PLAN -ELEKTRO UTOMHUSPLAN
ES102 - SITE ELECTRICAL PLAN AREA 01 -ELEKTRO UTOMHUSPLAN DEL 01
ES103 - SITE ELECTRICAL PLAN AREA 02 -ELEKTRO UTOMHUSPLAN DEL 02
ES104 - SITE ELECTRICAL PLAN AREA 03 -ELEKTRO UTOMHUSPLAN DEL 03
ES105 - SITE ELECTRICAL PLAN AREA 04 -ELEKTRO UTOMHUSPLAN DEL 04
ES106 - SITE ELECTRICAL PLAN AREA 05 -ELEKTRO UTOMHUSPLAN DEL 05
ES107 - OVERALL SITE LIGHTING PLAN -BELYSNINGS UTOMHUSPLAN
ES108 - SITE LIGHTING PLAN AREA 01 -BELYSNINGS UTOMHUSPLAN DEL 01
ES109 - SITE LIGHTING PLAN AREA 02 -BELYSNINGS UTOMHUSPLAN DEL 02
ES110 - SITE LIGHTING PLAN AREA 03 -BELYSNINGS UTOMHUSPLAN DEL 03
ES111 - SITE LIGHTING PLAN AREA 04 -BELYSNINGS UTOMHUSPLAN DEL 04
ES112 - SITE LIGHTING PLAN AREA 05 -BELYSNINGS UTOMHUSPLAN DEL 05
ES401 - ENLARGED ELECTRICAL SITE PLAN -FORSTØRRET ELEKTRO UTOMHUSPLAN
ES402 - ENLARGED ELECTRICAL SITE PLAN -FORSTØRRET ELEKTRO UTOMHUSPLAN
ES901 - SITE POWER RISER DIAGRAM -UTOMHUS STIGELEDNINGSSKJEMA
ES902 - SITE POWER RISER DIAGRAM -UTOMHUS STIGELEDNINGSSKJEMA
EY101 - OVERALL SITE ELECTRONIC SECURITY PLAN -OVERORDNET ANLEGGETS ELEKTRONISKE SIKKERHETSSYSTEM PLAN
EY102 - SITE ELECTRONIC SECURITY PLAN AREA 01 -ANLEGGETS ELEKRONISKE SIKKERHETSSYSTEMPLAN DEL 01
EY103 - SITE ELECTRONIC SECURITY PLAN AREA 02 -ANLEGGETS ELEKRONISKE SIKKERHETSSYSTEMPLAN DEL 02
EY104 - SITE ELECTRONIC SECURITY PLAN AREA 03 -ANLEGGETS ELEKRONISKE SIKKERHETSSYSTEMPLAN DEL 03
EY105 - SITE ELECTRONIC SECURITY PLAN AREA 04 -ANLEGGETS ELEKRONISKE SIKKERHETSSYSTEMPLAN DEL 04
EY106 - SITE ELECTRONIC SECURITY PLAN AREA 05 -ANLEGGETS ELEKRONISKE SIKKERHETSSYSTEMPLAN DEL 05
Telecommunications
TS101 - OVERALL SITE TELECOM PLAN -OVERSIKTSPLAN EKOM INFRASTRUKTUR
TS102 - SITE TELECOM PLAN AREA 01 - EKOM INFRASTRUKTUR DEL 01
TS103 - SITE TELECOM PLAN AREA 02 - EKOM INFRASTRUKTUR DEL 02
TS104 - SITE TELECOM PLAN AREA 03 - EKOM INFRASTRUKTUR DEL 03
TS105 - SITE TELECOM PLAN AREA 04 - EKOM INFRASTRUKTUR DEL 04
TS106 - SITE TELECOM PLAN AREA 05 - EKOM INFRASTRUKTUR DEL 05

File details come from the government source that posted it. Updated .