3.
5.
2.
3.
5.
40.4 m²
POST PARTUM
RECOVERY
23.9 m²
HOSPITALIZATION
12.0 m²
WORK ROOM
19.9 m²
DELIVERY
7.4 m²
CORRIDOR
9.9 m²
BREAK ROOM
113A
3.2 m²
SHOWER
113B
20.4 m²
CONSULTATION
7.7 m²
MIDWIFE ON-DUTY
102A
2.9 m²
SHOWER
102B
23.9 m²
DISPENSARY
110A
15.3 m²
CORRIDOR
45.0 m²
LOBBY / WAITING
50.4 m²
TERRACE
2.000 4.500 4.500 7.500 3.300 2.000 5.150 4.300
0.500 TYPICAL 2.000 2.400 2.000 12.250 2.000 8.450 4.150
33.250
.1
4 7
121212
6 4
4.9 m²
BATTERY
4.9 m²
MEDICINE
STORAGE
110B
8.
29.100
18.500 14.750
19 19
NTSA-101
1 HEALTH CLINIC FLOOR PLAN
# NOTE
15 INTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
16 LOUVERED VENT TO OUTSIDE
17 RAMP (MAXIMUM 8.3% SLOPE)
18 VERTICAL SUNSHADES (TYPICAL ON WEST, SOUTH, AND EAST FACADES)
19 VERTICAL LOUVER SUNSHADES
20 ROOF DRAIN CONNECTED TO METAL DOWNSPOUT, SLOPE ROOF TO DRAIN
21 WALL-MOUNTED LAVATORY
22 COUNTER-MOUNTED WATER BASIN
# NOTE
1 CAST-IN-PLACE CONCRETE BENCH
2 PIN BOARD (3000 W x 1250 H MM) 3 BUILT-IN STORAGE (MINIMUM INTERIOR DIMENSIONS 1600 W x 500 D mm) 4 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1800 W x 1200 H mm) 5 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1200 W x 1200 H mm) 6 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 900 W x 1200 H mm) 7 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 800 W x 1200 H mm)
8 EXTERIOR METAL ENTRY GATE
9 EXTERIOR METAL SINGLE DOOR
10 EXTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
11 EXTERIOR METAL DOUBLE DOOR
12 EXTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
13 INTERIOR METAL SINGLE DOOR
14 INTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-101
FL
O
O R
P
LA
N
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE
CODES AND REQUIREMENTS OF THE SOW.
A-102
A-102
A-102
A-102
FIN. FLOOR
0.500
ROOF
3.200
GRADE
0.000
T.O. WALL
1.600
A-102
444 4 719 1818
FIN. FLOOR
0.500
ROOF
3.200
GRADE
0.000
T.O. WALL
1.600
4 4 4 18 18
FIN. FLOOR
0.500
ROOF
3.200
GRADE
0.000
T.O. WALL
1.600
T.O. FOUNDATION
-1.000
NTSA-102
1 HEALTH CLINIC ROOF PLAN
NTSA-102
2 HEALTH CLINIC FRONT FACADE
NTSA-102
3 HEALTH CLINIC SIDE FACADE
NTSA-102
4 HEALTH CLINIC SECTION
# NOTE
15 INTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
16 LOUVERED VENT TO OUTSIDE
17 RAMP (MAXIMUM 8.3% SLOPE)
18 VERTICAL SUNSHADES (TYPICAL ON WEST, SOUTH, AND EAST FACADES)
19 VERTICAL LOUVER SUNSHADES
20 ROOF DRAIN CONNECTED TO METAL DOWNSPOUT, SLOPE ROOF TO DRAIN
21 WALL-MOUNTED LAVATORY
22 COUNTER-MOUNTED WATER BASIN
# NOTE
1 CAST-IN-PLACE CONCRETE BENCH
2 PIN BOARD (3000 W x 1250 H MM) 3 BUILT-IN STORAGE (MINIMUM INTERIOR DIMENSIONS 1600 W x 500 D mm) 4 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1800 W x 1200 H mm) 5 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1200 W x 1200 H mm) 6 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 900 W x 1200 H mm) 7 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 800 W x 1200 H mm)
8 EXTERIOR METAL ENTRY GATE
9 EXTERIOR METAL SINGLE DOOR
10 EXTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
11 EXTERIOR METAL DOUBLE DOOR
12 EXTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
13 INTERIOR METAL SINGLE DOOR
14 INTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-102
R O
O F
PL
AN
, E
LE
VA
TI
O N
S, S
EC
TI
O N
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
D es ig ne r
Au th or
C he ck er
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-103
BU
IL
D
IN
G P
H O
TO
G
R
AP
H S
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
D es ig ne r
Au th or
C he ck er
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NTSA-103
1 EXTERIOR VIEW - FRONT FACADE
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
NTSA-103
2 EXTERIOR VIEW - GATE
NTSA-103
5 INTERIOR VIEW - DELIVERY ROOM
NTSA-103
6 INTERIOR VIEW - DELIVERY ROOM
NTSA-103
7 INTERIOR VIEW - POST PARTUM RECOVERY
NTSA-103
4 EXTERIOR VIEW - DRAIN
NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE
ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE
GENERAL NATURE OF THE WORK BUT MAY DEPICT
FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL
APPLICABLE CODES AND REQUIREMENTS OF THE SOW.
NTSA-103
3 EXTERIOR VIEW - DOOR
1.
1.
5.900
1 1 1 1
5 5 5 5 5
9.000
4 4 4 4
1.8 m²
LATRINE
1.8 m²
LATRINE
1.8 m²
LATRINE
1.8 m²
LATRINE
TYPICAL
0.400
2 2 2
FIN. FLOOR
0.150
ROOF
3.000
GRADE
0.000
A-104
B.O. PIT
-2.000
44444
1 1 1 1
7 7 7 7
1.
FIN. FLOOR
0.150
ROOF
3.000
GRADE
0.000
B.O. PIT
-2.000
LATRINE
PIT
7 7
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-104
FL
O
O R
P
LA
N , E
LE
VA
TI
O
N , S
EC
TI
O N
LA
TR
IN
E
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
1 : 25A-104
1 LATRINE FLOOR PLAN
# NOTE
1 METAL DOOR WITH PADLOCK HASP
2 HOLE IN LATRINE FLOOR, PROVIDE ONE MOVEABLE CAST
CONCRETE BLOCK TO COVER ONE HOLE PER LATRINE
3 PIT FOUNDATION BELOW
4 PIT VENTILATION PIPE WITH FLY SCREEN
5 REMOVABLE CONCRETE COVER WITH EMBEDDED ANCHOR
POINTS FOR LIFTING
6 RAINWATER COLLECTION TANK FOR HANDWASHING, ATTACH TO
ROOF DOWNSPOUTS
7 VENTILATION OPENING
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
1 : 25A-104
2 LATRINE FRONT FACADE
1 : 25A-104
3 LATRINE SECTION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
ROOF
3.000
FIN. FLOOR
0.150
GRADE
0.000
ROOF
3.000
FIN. FLOOR
0.150
GRADE
0.000
2.000
2.
0.250 TYPICAL
3.2 m²
HAZARDOUS SOLID
WASTE STORAGE
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-105
FL
O
O R
P
LA
N , E
LE
VA
TI
O
N , S
EC
TI
O N
H
AZ
AR
D
O U
S
SO
LI
D
W
AS
TE
S
TO
R
AG
E
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
# NOTE
1 METAL DOOR WITH PADLOCK HASP
2 CONCRETE ROOF SLAB
3 VENTILATION OPENING
4 BIRD MESH INSTALLED ON OPENING
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
NTSA-105
3 SOUTH FACADE
NTSA-105
2 SECTION
NTSA-105
1 FLOOR PLAN
NTSA-105
4 PHOTOGRAPH
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE
ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE
GENERAL NATURE OF THE WORK BUT MAY DEPICT
FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL
APPLICABLE CODES AND REQUIREMENTS OF THE SOW.
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
ROOF
2.200
GRADE
0.000
T.O. INCINERATOR
1.000
ROOF
2.200
GRADE
0.000
B.O. PIT
-2.000
ASH PIT
T.O. INCINERATOR
1.000
4 6
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
A-106
FL
O
O R
P
LA
N , E
LE
VA
TI
O
N , S
EC
TI
O N
IN
C
IN
ER
AT
O
R
FY
A
FR
IC
O
M H
U M
AN
IT
AR
IA
N A
SS
IS
TA
N
C E:
B
EN
IN
G
O D
JE
KO
AR
A
H
EA
LT
H
C
LI
N
IC
EU
R
O
PE
D
IS
TR
IC
T W
IE
SB
AD
EN
, G
ER
M
AN
Y
# NOTE
1 CHIMNEY WITH RAINCOVER
2 PACKAGED STEEL INCINERATOR
3 FUEL LOADING AND ASH REMOVAL DOOR
4 VENTILATION OPENING
5 OPERABLE STEEL DOOR
6 SAND FILL
7 REMOVABLE CONCRETE COVER
ATTACHMENT #3: CONCEPTUAL FLOOR PLANS
NTSA-106
3 SOUTH FACADE
NTSA-106
2 SECTION
NTSA-106
1 FLOOR PLAN
NTSA-106
4 PHOTOGRAPH
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL
EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE
FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE
CODES AND REQUIREMENTS OF THE SOW.
NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE
ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE
GENERAL NATURE OF THE WORK BUT MAY DEPICT
FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL
APPLICABLE CODES AND REQUIREMENTS OF THE SOW.
| ar149_Godjekoara Health Clinic - Sheet - A-101 - FLOOR PLAN |
| Sheets |
| A-101 - FLOOR PLAN |
| A-102 - ROOF PLAN, ELEVATIONS, SECTION |
| A-103 - BUILDING PHOTOGRAPHS |
| ar149_Godjekoara Health Clinic - Sheet - A-102 - ROOF PLAN, ELEVATIONS, SECTION |
| Sheets |
| A-101 - FLOOR PLAN |
| A-102 - ROOF PLAN, ELEVATIONS, SECTION |
| A-103 - BUILDING PHOTOGRAPHS |
| ar149_Godjekoara Health Clinic - Sheet - A-103 - BUILDING PHOTOGRAPHS |
| Sheets |
| A-101 - FLOOR PLAN |
| A-102 - ROOF PLAN, ELEVATIONS, SECTION |
| A-103 - BUILDING PHOTOGRAPHS |
| ar149_Godjekoara Health Clinic_Latrines - Sheet - A-104 - FLOOR PLAN, ELEVATION, SECTION |
| Sheets |
| A-104 - FLOOR PLAN, ELEVATION, SECTION |
| ar149_Godjekoara Health Clinic_Hazardous Solid Waste Storage - Sheet - A-105 - FLOOR PLAN, ELEVATION, SECTION |
| Sheets |
| A-105 - FLOOR PLAN, ELEVATION, SECTION |
| ar149_Godjekoara Health Clinic_Incinerator - Sheet - A-106 - FLOOR PLAN, ELEVATION, SECTION |
| Sheets |
| A-106 - FLOOR PLAN, ELEVATION, SECTION |
File details come from the government source that posted it.