A.02.16.1.3_ar137_Att_3_Conceptual_Floor_Plans.pdf

PDF 3 MB Posted

Attached to
Benin - Money and Godekoara Health Clinics - Malanville
Solicitation number
W912GB19R0036
Issued by

About this file

Attachment 1.3 - Money Clinic Conceptual Floor Plan

View the file

Other files

File Type Posted
B.08.02.3_Att_3_-_Bid_Schedule_-_Benin_Health_Centers_Revised.docx DOCX document
B.08.02.4_Att_4_-_Price_and_Payment_Procedures_Revised.docx DOCX document
B.08.02.1_W912GB19R0036_Amendment_0001.pdf PDF
B.08.02.11_Att_11_Site_Visit_Attendee_Worksheet_19R0036.xlsx XLSX spreadsheet
B.08.02.8_Att_8_-_Specification_Binder_19R0036.pdf PDF
B.08.02.6_Att_6_-_BLA_Template_19R0036.docx DOCX document
A.02.16.2.4_ar149_Att_4_Dedication_Plaque.pdf PDF
A.02.16.1_Money_SOW_ar137_011010_30MAY2019.pdf PDF
B.08.02.3_Att_3_-_Bid_Schedule_-_Benin_Health_Centers.docx DOCX document
A.02.16.2.5_ar149_Att_5_01-2016_Preparation_of_Structural_Calculations_English.pdf PDF
B.08.02.10_Att_10_ExpOverviewSheet_19R0036.docx DOCX document
A.02.16.2.6_ar149_Att_6_The_Design_of_Ventilated_lmproved_Pit_Latrines.pdf PDF
A.02.16.2.3_ar149_Att_3_Conceptual_Floor_Plans.pdf PDF
A.02.16.1.4_ar137_Att_4_Dedication_Plaque.pdf PDF
A.02.16.2_Godjekoara_SOW_ar149_011010_30MAY2019.pdf PDF
B.08.02_W912GB19R0036_Benin_Clinics_Solicitation.pdf PDF
A.02.16.1.6_ar137_Att_6_TAG13_The_Design_of_VIP_Latrines.pdf PDF
A.02.16.2.1_ar149_Att_1_Project_Location_Map.pdf PDF
A.02.16.2.2_ar149_Att_2_Conceptual_Site_Plan.pdf PDF
A.02.16.1.2_ar137_Att_2_Conceptual_Site_Plan.pdf PDF
A.02.16.1.5_ar137_Att_5_01-2016_Preparation_of_Structural_Calculations_English.pdf PDF
A.02.16.1.1_ar137_Att_1_Project_Location_Map.pdf PDF
B.08.02.4_Att_4_-_Price_and_Payment_Procedures.docx DOCX document
B.08.02.7_Att_7_-_BLG_Template_19R0036.docx DOCX document
B.08.02.5_Att_5_-_Past_Performance_Questionnaire_-_19R0036.pdf PDF
B.08.02.9_Att_9_ExpInfoSheet_19R0036.docx DOCX document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3.

5.

2.

3.

5.

40.4 m²

POST PARTUM

RECOVERY

23.9 m²

HOSPITALIZATION

12.0 m²

WORK ROOM

19.9 m²

DELIVERY

7.4 m²

CORRIDOR

9.9 m²

BREAK ROOM

113A

3.2 m²

SHOWER

113B

20.4 m²

CONSULTATION

7.7 m²

MIDWIFE ON-DUTY

102A

2.9 m²

SHOWER

102B

23.9 m²

DISPENSARY

110A

15.3 m²

CORRIDOR

45.0 m²

LOBBY / WAITING

50.4 m²

TERRACE

2.000 4.500 4.500 7.500 3.300 2.000 5.150 4.300

0.500 TYPICAL 2.000 2.400 2.000 12.250 2.000 8.450 4.150

33.250

.1

4 7

121212

6 4

4.9 m²

BATTERY

4.9 m²

MEDICINE

STORAGE

110B

8.

29.100

18.500 14.750

NTSA-101

1 HEALTH CLINIC FLOOR PLAN

# NOTE

16 LOUVERED VENT TO OUTSIDE

17 RAMP (MAXIMUM 8.3% SLOPE)

18 VERTICAL SUNSHADES (TYPICAL ON WEST, SOUTH, AND EAST FACADES)

19 VERTICAL LOUVER SUNSHADES

20 ROOF DRAIN CONNECTED TO METAL DOWNSPOUT, SLOPE ROOF TO DRAIN

21 WALL-MOUNTED LAVATORY

22 WALL-MOUNTED WATER BASIN

# NOTE

1 CAST-IN-PLACE CONCRETE BENCH

2 PIN BOARD (3000 W x 1250 H MM) 3 BUILT-IN STORAGE (MINIMUM INTERIOR DIMENSIONS 1600 W x 500 D mm) 4 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1800 W x 1200 H mm) 5 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1200 W x 1200 H mm) 6 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 900 W x 1200 H mm) 7 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 800 W x 1200 H mm)

8 EXTERIOR METAL ENTRY GATE

9 EXTERIOR METAL SINGLE DOOR

10 EXTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

11 EXTERIOR METAL DOUBLE DOOR

12 EXTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

13 INTERIOR METAL SINGLE DOOR

14 INTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

15 INTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

FL

O

O R

P

LA

N

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

A-102

A-102

A-102

A-102

FIN. FLOOR

0.500

ROOF

3.200

GRADE

0.000

T.O. WALL

1.600

A-102

444 4 719 1818

FIN. FLOOR

0.500

ROOF

3.200

GRADE

0.000

T.O. WALL

1.600

4 4 4 18 18

FIN. FLOOR

0.500

ROOF

3.200

GRADE

0.000

T.O. WALL

1.600

T.O. FOUNDATION

-1.000

18 19

NTSA-102

1 HEALTH CLINIC ROOF PLAN

NTSA-102

2 HEALTH CLINIC FRONT FACADE

NTSA-102

3 HEALTH CLINIC SIDE FACADE

NTSA-102

4 HEALTH CLINIC SECTION

# NOTE

16 LOUVERED VENT TO OUTSIDE

17 RAMP (MAXIMUM 8.3% SLOPE)

18 VERTICAL SUNSHADES (TYPICAL ON WEST, SOUTH, AND EAST FACADES)

19 VERTICAL LOUVER SUNSHADES

20 ROOF DRAIN CONNECTED TO METAL DOWNSPOUT, SLOPE ROOF TO DRAIN

21 WALL-MOUNTED LAVATORY

22 WALL-MOUNTED WATER BASIN

# NOTE

1 CAST-IN-PLACE CONCRETE BENCH

2 PIN BOARD (3000 W x 1250 H MM) 3 BUILT-IN STORAGE (MINIMUM INTERIOR DIMENSIONS 1600 W x 500 D mm) 4 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1800 W x 1200 H mm) 5 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 1200 W x 1200 H mm) 6 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 900 W x 1200 H mm) 7 METAL LOUVER WINDOW W/ INSECT SCREEN (MIN. DIMENSIONS 800 W x 1200 H mm)

8 EXTERIOR METAL ENTRY GATE

9 EXTERIOR METAL SINGLE DOOR

10 EXTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

11 EXTERIOR METAL DOUBLE DOOR

12 EXTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

13 INTERIOR METAL SINGLE DOOR

14 INTERIOR METAL SINGLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

15 INTERIOR METAL DOUBLE DOOR W/ CURTAIN ROD INSTALLED ABOVE DOOR HEAD

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-102

R O

O F

PL

AN

, E

LE

VA

TI

O N

S, S

EC

TI

O N

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-103

BU

IL

D

IN

G P

H O

TO

G

R

AP

H S

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NTSA-103

1 EXTERIOR VIEW - FRONT FACADE

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

NTSA-103

2 EXTERIOR VIEW - GATE

NTSA-103

5 INTERIOR VIEW - DELIVERY ROOM

NTSA-103

6 INTERIOR VIEW - DELIVERY ROOM

NTSA-103

7 INTERIOR VIEW - POST PARTUM RECOVERY

NTSA-103

4 EXTERIOR VIEW - DRAIN

NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE

ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE

GENERAL NATURE OF THE WORK BUT MAY DEPICT

FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS

RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND REQUIREMENTS OF THE SOW.

NTSA-103

3 EXTERIOR VIEW - DOOR

1.

1.

5.900

1 1 1 1

5 5 5 5 5

9.000

4 4 4 4

1.8 m²

LATRINE

1.8 m²

LATRINE

1.8 m²

LATRINE

1.8 m²

LATRINE

TYPICAL

0.400

2 2 2

FIN. FLOOR

0.150

ROOF

3.000

GRADE

0.000

A-104

B.O. PIT

-2.000

44444

1 1 1 1

7 7 7 7

1.

FIN. FLOOR

0.150

ROOF

3.000

GRADE

0.000

B.O. PIT

-2.000

LATRINE

PIT

7 7

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-104

FL

O

O R

P

LA

N , E

LE

VA

TI

O

N , S

EC

TI

O N

LA

TR

IN

E

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

1 : 25A-104

1 LATRINE FLOOR PLAN

# NOTE

1 METAL DOOR WITH PADLOCK HASP

2 HOLE IN LATRINE FLOOR, PROVIDE ONE MOVEABLE CAST

CONCRETE BLOCK TO COVER ONE HOLE PER LATRINE

3 PIT FOUNDATION BELOW

4 PIT VENTILATION PIPE WITH FLY SCREEN

5 REMOVABLE CONCRETE COVER WITH EMBEDDED ANCHOR

POINTS FOR LIFTING

6 RAINWATER COLLECTION TANK FOR HANDWASHING, ATTACH TO

ROOF DOWNSPOUTS

7 VENTILATION OPENING

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

1 : 25A-104

2 LATRINE FRONT FACADE

1 : 25A-104

3 LATRINE SECTION

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

ROOF

3.000

FIN. FLOOR

0.150

GRADE

0.000

ROOF

3.000

FIN. FLOOR

0.150

GRADE

0.000

2.000

2.

0.250 TYPICAL

3.2 m²

HAZARDOUS SOLID

WASTE STORAGE

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-105

FL

O

O R

P

LA

N , E

LE

VA

TI

O

N , S

EC

TI

O N

H

AZ

AR

D

O U

S

SO

LI

D

W

AS

TE

S

TO

R

AG

E

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

# NOTE

1 METAL DOOR WITH PADLOCK HASP

2 CONCRETE ROOF SLAB

3 VENTILATION OPENING

4 BIRD MESH INSTALLED ON OPENING

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

NTSA-105

3 SOUTH FACADE

NTSA-105

2 SECTION

NTSA-105

1 FLOOR PLAN

NTSA-105

4 PHOTOGRAPH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE

ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE

GENERAL NATURE OF THE WORK BUT MAY DEPICT

FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS

RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND REQUIREMENTS OF THE SOW.

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

ROOF

2.200

GRADE

0.000

T.O. INCINERATOR

1.000

ROOF

2.200

GRADE

0.000

B.O. PIT

-2.000

ASH PIT

T.O. INCINERATOR

1.000

4 6

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-106

FL

O

O R

P

LA

N , E

LE

VA

TI

O

N , S

EC

TI

O N

IN

C

IN

ER

AT

O

R

FY

A

FR

IC

O

M H

U M

AN

IT

AR

IA

N A

SS

IS

TA

N

C E:

B

EN

IN

M

O N

EY

H

EA

LT

H C

LI

N

IC

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

# NOTE

1 CHIMNEY WITH RAINCOVER

2 PACKAGED STEEL INCINERATOR

3 FUEL LOADING AND ASH REMOVAL DOOR

4 VENTILATION OPENING

5 OPERABLE STEEL DOOR

6 SAND FILL

7 REMOVABLE CONCRETE COVER

ATTACHMENT #3: CONCEPTUAL FLOOR PLANS

NTSA-106

3 SOUTH FACADE

NTSA-106

2 SECTION

NTSA-106

1 FLOOR PLAN

NTSA-106

4 PHOTOGRAPH

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

NOTE: PHOTOGRAPHS ARE PROVIDED FOR REFERENCE

ONLY. PHOTOGRAPHS ARE INTENDED TO ILLUSTRATE THE

GENERAL NATURE OF THE WORK BUT MAY DEPICT

FEATURES WHICH ARE NOT IN THE SOW. CONTRACTOR IS

RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND REQUIREMENTS OF THE SOW.

ar137_Money Health Clinic - Sheet - A-101 - FLOOR PLAN
Sheets
A-101 - FLOOR PLAN
A-102 - ROOF PLAN, ELEVATIONS, SECTION
A-103 - BUILDING PHOTOGRAPHS
ar137_Money Health Clinic - Sheet - A-102 - ROOF PLAN, ELEVATIONS, SECTION
Sheets
A-101 - FLOOR PLAN
A-102 - ROOF PLAN, ELEVATIONS, SECTION
A-103 - BUILDING PHOTOGRAPHS
ar137_Money Health Clinic - Sheet - A-103 - BUILDING PHOTOGRAPHS
Sheets
A-101 - FLOOR PLAN
A-102 - ROOF PLAN, ELEVATIONS, SECTION
A-103 - BUILDING PHOTOGRAPHS
ar137_Money Health Clinic_Latrines - Sheet - A-104 - FLOOR PLAN, ELEVATION, SECTION
Sheets
A-104 - FLOOR PLAN, ELEVATION, SECTION
ar137_Money Health Clinic_Hazardous Solid Waste Storage - Sheet - A-105 - FLOOR PLAN, ELEVATION, SECTION
Sheets
A-105 - FLOOR PLAN, ELEVATION, SECTION
ar137_Money Health Clinic_Incinerator - Sheet - A-106 - FLOOR PLAN, ELEVATION, SECTION
Sheets
A-106 - FLOOR PLAN, ELEVATION, SECTION