EFFECTIVE: 22 Sep 2014

DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST

PETROLEUM MAINTENANCE CONTRACT

ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT

Please note: If an emergency exists that threatens health and/or the environment, you must respond in the manner addressed under your local Emergency Response Plan.

Today’s Date: 9/20/2017

Name of Requestor: LT Mendel / F.E. Strazzulla Your Commercial Phone #: 335-579-0529

Your DSN number: 624-2555 / 2786 Your Handy Phone #: 39-335-579-0529

Installation: NAS Sigonella Work Requested at Building #: 605 Filter Pad

Please provide SPECIFIC details about the emergency or work request (e.g. a description of the problem encountered, type of fuel system (MOGAS, JP, Dispenser #, Tank #, Oil/Water Separator, etc):

Remove the Old Vertical Filter Vessels FS-1, FS-2, PF-1, PF-2. Replace them by new segments of pipes connecting the existing 6” Return Line / 8” Receiving Line to the FS-1-2-3-4-5-6 lines. Provide for Low Point Drains, High Point Vents and replace the Relief Valve where necessary (details will be supplied on site by the local Fuels Division Eng.

Provide the Name and Number of the Responsible Officer (RO) That the Contractor Shall Contact Upon Arrival on Site - The RO must ensure access for the contractor to all facilities that require service. Contractually Only the RO or His/Her Designated Alternate is Authorized to Escort the Contractor and Sign for Services Rendered.

For emergency work requests (EWRs): Emergency Work Requests should be submitted as soon as possible after discovery. Non-emergency work requests do not require the following information.

Name and Phone of Person Discovering the Emergency:

Date & Time of Discovery:

Date and Time Call Placed to USACE, Europe District :

Who Did You Notify at USACE (Name):

Date and Time Responsible Official (RO) Was Notified:

Angela-Rene.Tugaoen@usace.army.mil USACE Europe District Office:+1.623.282.9865 mailto:Angela-Rene.Tugaoen@usace.army.mil

EFFECTIVE: 22 Sep 2014

DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST

PETROLEUM MAINTENANCE CONTRACT

ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT

Pleasenote:Ifanemergencyexiststhatthreatenshealthand/ortheenvironment,youmustrespondin
themanneraddressedunderyourlocalEmergencyResponsePlan.

Today’s Date: 12/18/2017

Name of Requestor: LT Mendel Your Commercial Phone #: +39 331‐186‐0187

Your DSN number: 624‐2555 Your Handy Phone #:

Installation: NAS Sigonella Work Requested at Building #: Fuels I & II

PleaseprovideSPECIFICdetailsabouttheemergencyorworkrequest(e.g.adescriptionofthe
problemencountered,typeoffuelsystem(MOGAS,JP,Dispenser#,Tank#,Oil/WaterSeparator,etc):

Replace all threaded TRV valves with flanged TRV valves in accordance with DOD AW 78‐24‐27.

‐ Add1”ballvalvesw/lockablehandles.
‐ Add1”teew/1”blindflangeforvalvetestingandcalibration.
ProvidetheNameandNumberoftheResponsibleOfficer(RO)ThattheContractorShallContactUpon
ArrivalonSite‐TheROmustensureaccessforthecontractortoallfacilitiesthatrequireservice.ContractuallyOnly
theROorHis/HerDesignatedAlternateisAuthorizedtoEscorttheContractorandSignforServicesRendered.

LT Mendel, Igor

Foremergencyworkrequests(EWRs):EmergencyWorkRequestsshouldbesubmittedassoonaspossible
afterdiscovery.Non‐emergencyworkrequestsdonotrequirethefollowinginformation.

Name and Phone of Person Discovering the Emergency:

Date & Time of Discovery:

Date and Time Call Placed to USACE, Europe District :

Who Did You Notify at USACE (Name):

Date and Time Responsible Official (RO) Was Notified:

Forms can be emailed to Hollie Eljizi, USACE Europe District at Hollie.m.eljizi@usace.army.mil

Office:0611‐9744‐2157
DSN:570‐2157
Cell:0172‐8177452

1" THERMAL

RELIEF VALVE

1" BALL VALVE

1" x 3" NIPPLE

WELDING BRANCH

N.C.

N.O.

N.O.

90 DEG. ELBOW

TO 1" WELD-O-LET

TANK PENETRATION

OR PIPE CONNECTION

LENGTH TO SUIT LOCATION

NOTE:

ALL FITTINGS TO BE SOCKET-WELD TYPE (INCLUDING THE WELDING

BRANCH) EXCEPT AS INDICATED, ALL VALVES SHALL BE FLANGED.

BALL VALVE

PIPE

HYDRAULIC

COUPLER OPTION

TYP.

1/4"

2 3/4"

2 3/4"

2 3/4" 2 3/4"

4" 4"

4"

4"

11/16" DIA. HOLE (TYP.)

BASE PLATE

PROVIDE 1/4" THICK

TEFLON INSULATION

STRIP BETWEEN PIPE

AND SADDLE.

CAST IRON

SADDLE

REDUCER

3" CARBON

STEEL

BASE PLATE,

SEE DETAIL

ADJUSTING

BAR

THREADED NIPPLE

1/4" DRAIN HOLE

4 1/2" EXPANSION

ANCHOR BOLTS

WITH 3 1/2" MIN.

EMBEDMENT

TO

S

U

IT

L O

C

AT

IO

N

1/2" PL

INSULATING

GASKET

MATERIAL

INSULATING

GASKET

MATERIAL

ARRESTER

CONNECTION

BRACKET

NOTE:

WRAP ENTIRE INSULATING FLANGE IN PVC PIPING AND

SECURE WITH STAINLESS STEEL BAND CLAMP. LEAVE

LIGHTING SURGE ARRESTER EXPOSED.

LIGHTNING SURGE

ARRESTER, SEE

SHEET EC503

TO PUMP

HOUSE

FROM FUEL

LINE

8"

8" x 6" RED.

6"

1"

IF N.O.

6" 90 PSIG6" x 4" RED.

(TYP.)

2 1/2" SINGLE POINT

RECEPTACLE (D-1

NOZZLE ADAPTOR

TYP. OF 4)

4" 4"

N.O.

IF

30 PSIG

6" x 4"

REDUCER

(TYP.)

2 1/2" SINGLE POINT

RECEPTACLE (D-1

NOZZLE ADAPTOR

TYP. OF 2)

8"

PSIG

0-300

PSIG

0-100

8"

8" x 6" RED.

N.C.

IF

N.O.

6"

N.O. IF

6" (OR 4")

2" TO PRODUCT

RECOVERY TANK

DRAIN LINE

2" x 1" RED.

IF

6"

PSIG

6" x 4" TEE

2" ALUMINUM

MALE CAM TYPE

CONNECTOR

WITH DUST CAP

6" x 4" RED. EL.

BOWSER

PUMP-OFF

PUMP

2 1/2" SINGLE POINT

RECEPTACLE

4" OR 6" HYDRANT CONTROL

VALVE WITH 6" x 4" ADAPTER

ECCENTRIC

INCREASER WITH

HORIZONTAL

PORTION ON TOP

BASKET STRAINER

SIZES OF LETTERS AND BANDS

PIPE DIAMETER

(INCHES)

A

BAND WIDTH

AND SPACING

(INCHES)

B

TITLE LETTER

SIZE

(INCHES)

C

BACKGROUND

AND ARROWS

(INCHES)

UNDER 3

3 - 6

6 - 9

OVER 9

0.5

4.5

"B" HIGH WHITE LETTERS

ON BLACK BACKGROUND

PRODUCT SYMBOL

JET FUEL JP-8

"A" "A"

"C

YELLOW BANDS (3 EA.)

ALL AROUND

YELLOW

FLOW ARROW

F-34

4 x "C" YELLOW LETTERS AND

YELLOW DASHED OUTLINE

(NATO)

JET FUEL F-24

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

MS505

H

YD

R

AN

T H

O S E

T R

U C

K C

H

EC

K- O

U T/

P A N

TO

G

R A P

H F

L U

SH

D

ET

AI

L S

O M

A H A

D

IS

T R

IC

T

AU

G U

ST

D O

D S

TA

N

D A R

D D

ES

IG

N A

W

-2

4 -

P R

E S

SU

R

IZ

ED

H

YD

R

AN

T

F U

EL

IN

G

S

YS

TE

M

T

YP

E

III

SCALE: NTS

THERMAL RELIEF VALVE PIPINGE1

SCALE: NTS

ADJUSTABLE SADDLE

SUPPORT DETAILD5

SCALE: NTS

LIGHTNING SURGE ARRESTER DETAILA1 SCALE: NTS

HYDRANT HOSE TRUCK CHECK-OUT / PANTOGRAPH FLUSH STATION PIPING DIAGRAMA5

SCALE: NTS

PRODUCT FLOW SYMBOL DETAILSE8

Progr. # Installation Facility Site S/N Set Point PSI Body Year of Installation

1 Fuels 2 605 Filter Pad 5143‐2 225 CS 2010

2 " " " " ‐9 " " "

3 " " " " ‐1 " " "

4 " " " " ‐5 " " "

5 " " " " ‐6 " " "

6 " " " " ‐8 " " "

7 " " " " ‐7 " " "

8 " " " " ‐10 " SS "

9 " " " " ‐3 " CS "

10 " " " " ‐4 " " "

11 " 473 Pump Pad 72330 280 " 2003

12 " " " 72319 280 " "

13 " " " 72329 280 " "

14 " 475 Tank 2 114149 145 " 2014‐15

15 " " " 113592 " " "

16 " " " 113593 " " "

17 " 474 Tank 1 " ‐1 " " "

18 " " " " ‐4 " " "

19 " " " 72933 " " "

20 " 468‐W TFS 16072892 " SS 2016

21 " " " " ‐3 " " "

22 Fuels 1 1034 401 6801‐96 " " 2005

23 " " " 118421 " " 2014

24 " " " 6801‐100 " " 2005

25 " " " " ‐92 " " "

26 " " " " ‐95 " " "

27 " " " " ‐88 " " "

28 " " " " ‐46 " CS "

29 " " " " ‐82 " " "

30 " 1033 402 6801‐89 " SS "

31 " " " 118422 " " 2014

32 " " " 6801‐98 " " 2005

33 " " " " ‐98 " " "

34 " " " 118423 " " 2014

35 " " " 6801‐93 " " 2005

36 " " " " ‐24 " CS 2005

37 " " " " ‐71 " " 2005

38 " 1035 403 " ‐5 " " 2005

39 " " " 403‐1 " " "

40 " " " 6801‐60 " " "

41 " " " " ‐53 " " "

42 " " " " ‐69 " " "

43 " " " " ‐37 " " "

44 " " " " ‐67 " " "

SIGO F1/F2 Thermal Relief Valves Inventory & Calib Status

45 " " " " ‐3 " " "

46 " " " 9826‐2 " " "

47 " 1036 404 6801‐80 " " "

48 " " " " ‐51 " " "

49 " " " " ‐47 " " "

50 " " " " ‐84 " " "

51 " " " " ‐1 " " "

52 " " " " ‐79 " " "

53 " " " " ‐50 " " "

54 " " " " ‐32 " " "

55 " " " 9826‐1 " " "

56 " 1032 405 6801‐48 " " "

57 " " " " ‐34 " " "

58 " " " " ‐70 " " "

59 " " " " ‐61 " " "

60 " " " " ‐59 " " "

61 " " " " ‐66 " " "

62 " " " " ‐13 " " "

63 " " " " ‐30 " " "

64 " 1031 406 6801‐12 " " "

65 " " " " ‐11 " " "

66 " " " 9826‐1 " " "

67 " " " 406‐1 " " "

68 " " " 406‐2 " " "

69 " " " 114148 " " "

70 " 1037 407 6801‐76 " " "

71 " " " " ‐43 " " "

72 " " " 9826‐4 " " "

73 " " " 6801‐49 " " "

74 " " " 407‐1 " " "

75 " " " 6801‐31 " " "

76 " 1038 Filter Pad 1038‐1 " " "

77 " " 42196‐1 " " "

78 " " 6801‐75 " " "

79 " " " ‐90 " SS "

80 " " " ‐87 " CS "

81 " " " ‐26 " " "

82 " " " ‐63 " " "

83 " " 1038‐2 " " "

84 " " 6801‐42 " " "

85 " " " ‐86 " " "

86 " " " ‐54 " " "

87 " " ‐52 " " "

88 " 1041 T‐302 6801‐44 " " "

89 " " " " ‐36 " " "

90 " 1042 T‐201 " ‐74 " " "

91 " " " " ‐02 " " "

92 " " " " ‐35 " " "

93 " " " " ‐39 " " "

94 " 1043 T‐202 " ‐41 " " "

95 " " " " ‐81 " " "

96 " " " " ‐72 " " "

97 " " " " ‐65 " " "

98 " 1044 T‐203 " ‐29 " " "

99 " " " " ‐78 " " "

100 " " " " ‐09 " " "

101 " " " 6801‐68 " " "

102 " 1045 T‐101 6801‐23 " " "

103 " " " " ‐20 " " "

104 " " " " ‐56 " " "

105 " " " " ‐77 " " "

106 " " " " ‐16 " " "

107 " " " " ‐17 " " "

108 " " " " ‐39 " " "

109 " 1046 T‐102 6801‐8 " " "

110 " " ‐25 " " ‐25 " " "

111 " " ‐4 " " ‐4 " " "

112 " " ‐15 " " ‐15 " " "

113 " " ‐28 " " ‐28 " " "

114 " " ‐85 " " ‐85 " " "

115 " " ‐22 " " ‐22 " " "

116 " 1050 T‐301 6801‐19 " " "

Attachment I - Firm Fixed Price Minor Repair Service Order Request Forms
Attachment I
DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST
PETROLEUM MAINTENANCE CONTRACT
ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT
For emergency work requests (EWRs): Emergency Work Requests should be submitted as soon as possible after discovery. Non-emergency work requests do not require the following information.
Name and Phone of Person Discovering the Emergency:
Date and Time Responsible Official (RO) Was Notified:

SIG-096, USACE POL WorkRequest - TRV replacement