EFFECTIVE: 22 Sep 2014
DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST
PETROLEUM MAINTENANCE CONTRACT
ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT
Please note: If an emergency exists that threatens health and/or the environment, you must respond in the manner addressed under your local Emergency Response Plan.
Today’s Date: 9/20/2017
Name of Requestor: LT Mendel / F.E. Strazzulla Your Commercial Phone #: 335-579-0529
Your DSN number: 624-2555 / 2786 Your Handy Phone #: 39-335-579-0529
Installation: NAS Sigonella Work Requested at Building #: 605 Filter Pad
Please provide SPECIFIC details about the emergency or work request (e.g. a description of the problem encountered, type of fuel system (MOGAS, JP, Dispenser #, Tank #, Oil/Water Separator, etc):
Remove the Old Vertical Filter Vessels FS-1, FS-2, PF-1, PF-2. Replace them by new segments of pipes connecting the existing 6” Return Line / 8” Receiving Line to the FS-1-2-3-4-5-6 lines. Provide for Low Point Drains, High Point Vents and replace the Relief Valve where necessary (details will be supplied on site by the local Fuels Division Eng.
Provide the Name and Number of the Responsible Officer (RO) That the Contractor Shall Contact Upon Arrival on Site - The RO must ensure access for the contractor to all facilities that require service. Contractually Only the RO or His/Her Designated Alternate is Authorized to Escort the Contractor and Sign for Services Rendered.
For emergency work requests (EWRs): Emergency Work Requests should be submitted as soon as possible after discovery. Non-emergency work requests do not require the following information.
Name and Phone of Person Discovering the Emergency:
Date & Time of Discovery:
Date and Time Call Placed to USACE, Europe District :
Who Did You Notify at USACE (Name):
Date and Time Responsible Official (RO) Was Notified:
Angela-Rene.Tugaoen@usace.army.mil USACE Europe District Office:+1.623.282.9865 mailto:Angela-Rene.Tugaoen@usace.army.mil
EFFECTIVE: 22 Sep 2014
DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST
PETROLEUM MAINTENANCE CONTRACT
ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT
| Please | note: | If | an | emergency | exists | that | threatens | health | and/or | the | environment, | you | must | respond | in | |
| the | manner | addressed | under | your | local | Emergency | Response | Plan. |
Today’s Date: 12/18/2017
Name of Requestor: LT Mendel Your Commercial Phone #: +39 331‐186‐0187
Your DSN number: 624‐2555 Your Handy Phone #:
Installation: NAS Sigonella Work Requested at Building #: Fuels I & II
| Please | provide | SPECIFIC | details | about | the | emergency | or | work | request | (e.g. | a | description | of | the | |||
| problem | encountered, | type | of | fuel | system | (MOGAS, | JP, | Dispenser | #, | Tank | #, | Oil/Water | Separator, | etc): |
Replace all threaded TRV valves with flanged TRV valves in accordance with DOD AW 78‐24‐27.
| ‐ Add | 1” | ball | valves | w/lockable | handles. | |||||
| ‐ Add | 1” | tee | w/1” | blind | flange | for | valve | testing | and | calibration. |
| Provide | the | Name | and | Number | of | the | Responsible | Officer | (RO) | That | the | Contractor | Shall | Contact | Upon | ||||||
| Arrival | on | Site | ‐ | The | RO | must | ensure | access | for | the | contractor | to | all | facilities | that | require | service. | Contractually | Only | ||
| the | RO | or | His/Her | Designated | Alternate | is | Authorized | to | Escort | the | Contractor | and | Sign | for | Services | Rendered. |
LT Mendel, Igor
| For | emergency | work | requests | (EWRs): | Emergency | Work | Requests | should | be | submitted | as | soon | as | possible | |
| after | discovery. | Non‐emergency | work | requests | do | not | require | the | following | information. |
Name and Phone of Person Discovering the Emergency:
Date & Time of Discovery:
Date and Time Call Placed to USACE, Europe District :
Who Did You Notify at USACE (Name):
Date and Time Responsible Official (RO) Was Notified:
Forms can be emailed to Hollie Eljizi, USACE Europe District at Hollie.m.eljizi@usace.army.mil
| Office: | 0611‐9744‐2157 |
| DSN: | 570‐2157 |
| Cell: | 0172‐8177452 |
1" THERMAL
RELIEF VALVE
1" BALL VALVE
1" x 3" NIPPLE
WELDING BRANCH
N.C.
N.O.
N.O.
90 DEG. ELBOW
TO 1" WELD-O-LET
TANK PENETRATION
OR PIPE CONNECTION
LENGTH TO SUIT LOCATION
NOTE:
ALL FITTINGS TO BE SOCKET-WELD TYPE (INCLUDING THE WELDING
BRANCH) EXCEPT AS INDICATED, ALL VALVES SHALL BE FLANGED.
BALL VALVE
PIPE
HYDRAULIC
COUPLER OPTION
TYP.
1/4"
2 3/4"
2 3/4"
2 3/4" 2 3/4"
4" 4"
4"
4"
11/16" DIA. HOLE (TYP.)
BASE PLATE
PROVIDE 1/4" THICK
TEFLON INSULATION
STRIP BETWEEN PIPE
AND SADDLE.
CAST IRON
SADDLE
REDUCER
3" CARBON
STEEL
BASE PLATE,
SEE DETAIL
ADJUSTING
BAR
THREADED NIPPLE
1/4" DRAIN HOLE
4 1/2" EXPANSION
ANCHOR BOLTS
WITH 3 1/2" MIN.
EMBEDMENT
TO
S
U
IT
L O
C
AT
IO
N
1/2" PL
INSULATING
GASKET
MATERIAL
INSULATING
GASKET
MATERIAL
ARRESTER
CONNECTION
BRACKET
NOTE:
WRAP ENTIRE INSULATING FLANGE IN PVC PIPING AND
SECURE WITH STAINLESS STEEL BAND CLAMP. LEAVE
LIGHTING SURGE ARRESTER EXPOSED.
LIGHTNING SURGE
ARRESTER, SEE
SHEET EC503
TO PUMP
HOUSE
FROM FUEL
LINE
8"
8" x 6" RED.
6"
1"
IF N.O.
6" 90 PSIG6" x 4" RED.
(TYP.)
2 1/2" SINGLE POINT
RECEPTACLE (D-1
NOZZLE ADAPTOR
TYP. OF 4)
4" 4"
N.O.
IF
30 PSIG
6" x 4"
REDUCER
(TYP.)
2 1/2" SINGLE POINT
RECEPTACLE (D-1
NOZZLE ADAPTOR
TYP. OF 2)
8"
PSIG
0-300
PSIG
0-100
8"
8" x 6" RED.
N.C.
IF
N.O.
6"
N.O. IF
6" (OR 4")
2" TO PRODUCT
RECOVERY TANK
DRAIN LINE
2" x 1" RED.
IF
6"
PSIG
6" x 4" TEE
2" ALUMINUM
MALE CAM TYPE
CONNECTOR
WITH DUST CAP
6" x 4" RED. EL.
BOWSER
PUMP-OFF
PUMP
2 1/2" SINGLE POINT
RECEPTACLE
4" OR 6" HYDRANT CONTROL
VALVE WITH 6" x 4" ADAPTER
ECCENTRIC
INCREASER WITH
HORIZONTAL
PORTION ON TOP
BASKET STRAINER
SIZES OF LETTERS AND BANDS
PIPE DIAMETER
(INCHES)
A
BAND WIDTH
AND SPACING
(INCHES)
B
TITLE LETTER
SIZE
(INCHES)
C
BACKGROUND
AND ARROWS
(INCHES)
UNDER 3
3 - 6
6 - 9
OVER 9
0.5
4.5
"B" HIGH WHITE LETTERS
ON BLACK BACKGROUND
PRODUCT SYMBOL
JET FUEL JP-8
"A" "A"
"C
YELLOW BANDS (3 EA.)
ALL AROUND
YELLOW
FLOW ARROW
F-34
4 x "C" YELLOW LETTERS AND
YELLOW DASHED OUTLINE
(NATO)
JET FUEL F-24
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
MS505
H
YD
R
AN
T H
O S E
T R
U C
K C
H
EC
K- O
U T/
P A N
TO
G
R A P
H F
L U
SH
D
ET
AI
L S
O M
A H A
D
IS
T R
IC
T
AU
G U
ST
D O
D S
TA
N
D A R
D D
ES
IG
N A
W
-2
4 -
P R
E S
SU
R
IZ
ED
H
YD
R
AN
T
F U
EL
IN
G
S
YS
TE
M
T
YP
E
III
SCALE: NTS
THERMAL RELIEF VALVE PIPINGE1
SCALE: NTS
ADJUSTABLE SADDLE
SUPPORT DETAILD5
SCALE: NTS
LIGHTNING SURGE ARRESTER DETAILA1 SCALE: NTS
HYDRANT HOSE TRUCK CHECK-OUT / PANTOGRAPH FLUSH STATION PIPING DIAGRAMA5
SCALE: NTS
PRODUCT FLOW SYMBOL DETAILSE8
Progr. # Installation Facility Site S/N Set Point PSI Body Year of Installation
1 Fuels 2 605 Filter Pad 5143‐2 225 CS 2010
2 " " " " ‐9 " " "
3 " " " " ‐1 " " "
4 " " " " ‐5 " " "
5 " " " " ‐6 " " "
6 " " " " ‐8 " " "
7 " " " " ‐7 " " "
8 " " " " ‐10 " SS "
9 " " " " ‐3 " CS "
10 " " " " ‐4 " " "
11 " 473 Pump Pad 72330 280 " 2003
12 " " " 72319 280 " "
13 " " " 72329 280 " "
14 " 475 Tank 2 114149 145 " 2014‐15
15 " " " 113592 " " "
16 " " " 113593 " " "
17 " 474 Tank 1 " ‐1 " " "
18 " " " " ‐4 " " "
19 " " " 72933 " " "
20 " 468‐W TFS 16072892 " SS 2016
21 " " " " ‐3 " " "
22 Fuels 1 1034 401 6801‐96 " " 2005
23 " " " 118421 " " 2014
24 " " " 6801‐100 " " 2005
25 " " " " ‐92 " " "
26 " " " " ‐95 " " "
27 " " " " ‐88 " " "
28 " " " " ‐46 " CS "
29 " " " " ‐82 " " "
30 " 1033 402 6801‐89 " SS "
31 " " " 118422 " " 2014
32 " " " 6801‐98 " " 2005
33 " " " " ‐98 " " "
34 " " " 118423 " " 2014
35 " " " 6801‐93 " " 2005
36 " " " " ‐24 " CS 2005
37 " " " " ‐71 " " 2005
38 " 1035 403 " ‐5 " " 2005
39 " " " 403‐1 " " "
40 " " " 6801‐60 " " "
41 " " " " ‐53 " " "
42 " " " " ‐69 " " "
43 " " " " ‐37 " " "
44 " " " " ‐67 " " "
SIGO F1/F2 Thermal Relief Valves Inventory & Calib Status
45 " " " " ‐3 " " "
46 " " " 9826‐2 " " "
47 " 1036 404 6801‐80 " " "
48 " " " " ‐51 " " "
49 " " " " ‐47 " " "
50 " " " " ‐84 " " "
51 " " " " ‐1 " " "
52 " " " " ‐79 " " "
53 " " " " ‐50 " " "
54 " " " " ‐32 " " "
55 " " " 9826‐1 " " "
56 " 1032 405 6801‐48 " " "
57 " " " " ‐34 " " "
58 " " " " ‐70 " " "
59 " " " " ‐61 " " "
60 " " " " ‐59 " " "
61 " " " " ‐66 " " "
62 " " " " ‐13 " " "
63 " " " " ‐30 " " "
64 " 1031 406 6801‐12 " " "
65 " " " " ‐11 " " "
66 " " " 9826‐1 " " "
67 " " " 406‐1 " " "
68 " " " 406‐2 " " "
69 " " " 114148 " " "
70 " 1037 407 6801‐76 " " "
71 " " " " ‐43 " " "
72 " " " 9826‐4 " " "
73 " " " 6801‐49 " " "
74 " " " 407‐1 " " "
75 " " " 6801‐31 " " "
76 " 1038 Filter Pad 1038‐1 " " "
77 " " 42196‐1 " " "
78 " " 6801‐75 " " "
79 " " " ‐90 " SS "
80 " " " ‐87 " CS "
81 " " " ‐26 " " "
82 " " " ‐63 " " "
83 " " 1038‐2 " " "
84 " " 6801‐42 " " "
85 " " " ‐86 " " "
86 " " " ‐54 " " "
87 " " ‐52 " " "
88 " 1041 T‐302 6801‐44 " " "
89 " " " " ‐36 " " "
90 " 1042 T‐201 " ‐74 " " "
91 " " " " ‐02 " " "
92 " " " " ‐35 " " "
93 " " " " ‐39 " " "
94 " 1043 T‐202 " ‐41 " " "
95 " " " " ‐81 " " "
96 " " " " ‐72 " " "
97 " " " " ‐65 " " "
98 " 1044 T‐203 " ‐29 " " "
99 " " " " ‐78 " " "
100 " " " " ‐09 " " "
101 " " " 6801‐68 " " "
102 " 1045 T‐101 6801‐23 " " "
103 " " " " ‐20 " " "
104 " " " " ‐56 " " "
105 " " " " ‐77 " " "
106 " " " " ‐16 " " "
107 " " " " ‐17 " " "
108 " " " " ‐39 " " "
109 " 1046 T‐102 6801‐8 " " "
110 " " ‐25 " " ‐25 " " "
111 " " ‐4 " " ‐4 " " "
112 " " ‐15 " " ‐15 " " "
113 " " ‐28 " " ‐28 " " "
114 " " ‐85 " " ‐85 " " "
115 " " ‐22 " " ‐22 " " "
116 " 1050 T‐301 6801‐19 " " "
| Attachment I - Firm Fixed Price Minor Repair Service Order Request Forms |
| Attachment I |
| DLA CAPITALIZED FUEL FACILITIES – WORK REQUEST |
| PETROLEUM MAINTENANCE CONTRACT |
| ADMINISTERED BY THE U.S. ARMY CORPS OF ENGINEERS, EUROPE DISTRICT |
| For emergency work requests (EWRs): Emergency Work Requests should be submitted as soon as possible after discovery. Non-emergency work requests do not require the following information. |
| Name and Phone of Person Discovering the Emergency: |
| Date and Time Responsible Official (RO) Was Notified: |
SIG-096, USACE POL WorkRequest - TRV replacement
| OD74MS505 |
| Sheets |
| MS505 - HYDRANT HOSE TRUCK CHECK-OUT/PANTOGRAPH FLUSH DETAILS |
TestLog Dec2017
File details come from the government source that posted it.