A.01.38_-_Attachment_2_-_Architectural_Floor_Plans.pdf

PDF 71 KB Posted

Attached to
Design-Build contract for the 34th Military labor and delivery renovation
Solicitation number
W912GB-18-R-0025
Issued by

About this file

Floor Plans

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

1.

7.

2.

1.

1.00 4.80 2.50 2.50 2.80 2.80 1.60

2.

2.

17.00

EXISTING STRUCTURE

(NOT IN CONTRACT)

HOSPITAL EAST WING

(NOT IN CONTRACT)

COVERED WALKWAY

COVERED ENTRY

19 m²

ENTRY / STAIRS

12 m²

RECEPTION

29 m²

CORRIDOR

2 m²

ELECTRICAL

12 m²

LABOR / DELIVERY

12 m²

LABOR / DELIVERY

5 m²

Room

5 m²

WASHROOM

31 m²

SURGICAL SUITE

4 m²

WASHROOM

110A 4 m²

STORAGE

110B

7 m²

ROOM

3 m²

TOILET

105A

2.40 2.60

5.00

2.

3.

1.

2.

2.

3.00

.0

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F E

N G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

S U

BM

IT

TE

D

B Y:

S

IZ

E:

C H

EC

K E

D B

Y:

A N

SI

'D

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

O

PT

IO

N

R E N

O

VA

TE

E

X I

ST

IN

G

R O

O M

S th

M

IL

IT

AR

Y H

O

SP

IT

AL

L

AB

O R

A N

D D

EL

IV

ER

Y

FR

EE

TO

W

N , S

IE

R

R A

LE

O

N E

E U

R O

PE

D

IS

TR

I C T

W

IE

SB

AD

EN

, G

E R

M

AN

Y

NTSA-101

1 EXISTING CONSTRUCTION

# NOTE

1 EXISTING ROOF LINE ABOVE

2 NEW ROOF LINE ABOVE

3 PROVIDE NEW FINISHES IN EXISTING ROOM

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

PLAN NORTH

ATTACHMENT #2: ARCHITECTURAL FLOOR PLANS

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

UP

EXISTING STRUCTURE

(NOT IN CONTRACT)

HOSPITAL EAST WING

(NOT IN CONTRACT)

31 m²

SURGICAL SUITE

4 m²

WASHROOM

110A 4 m²

STORAGE

110B

5 m²

NEW STORAGE

110C 5 m²

NEW TOILET

106A

12 m²

LABOR / DELIVERY

12 m²

LABOR / DELIVERY

3 m²

TOILET

105A

41 m²

CORRIDOR

4 m²

ELECTRICAL

12 m²

RECEPTION

19 m²

ENTRY / STAIRS

COVERED ENTRY

6 m²

NEW WASHROOM

NEW COVERED

WALKWAY

35 m²

NEW NICU

18 m²

NEW ANESTHESIA /

NURSE PREP

11 m²

NEW OFFICE

3 m²

NEW SHOWER

113A

13 m²

NEW NURSE

BREAKROOM

3 m²

NEW TOILET

115A

3 3

3 3

6 m²

STORAGE

2.

5.

6.80 3.00 5.20 2.00

6 m²

BATTERY ROOM

NTSA-102

1 NEW CONSTRUCTION AND RENOVATION

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL

EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE

FOR PROVIDING A DESIGN THAT MEETS ALL APPLICABLE

CODES AND REQUIREMENTS OF THE SOW.

PLAN NORTH

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

AR

M

Y C

O R

PS

O

F E

N G

IN

EE

R S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

S U

BM

IT

TE

D

B Y:

S

IZ

E:

C H

EC

K E

D B

Y:

A N

SI

'D

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-102

O

PT

IO

N

R E N

O

VA

TI

O

N A

N D

A D

D

IT

I O N th

M

IL

IT

AR

Y H

O

SP

IT

AL

L

AB

O R

A N

D D

EL

IV

ER

Y

FR

EE

TO

W

N , S

IE

R

R A

LE

O

N E

E U

R O

PE

D

IS

TR

I C T

W

IE

SB

AD

EN

, G

E R

M

AN

Y

D es ig ne r

A ut ho r

C he ck er

# NOTE

1 EXISTING ROOF LINE ABOVE

2 NEW ROOF LINE ABOVE

3 PROVIDE NEW FINISHES IN EXISTING ROOM

ATTACHMENT #2: ARCHITECTURAL FLOOR PLANS

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

File details come from the government source that posted it.