CURB STOP AND BOX
4" - 45 DEGREE BENDS
4" DOUBLE WYE WITH
CONNECTOR
SEWER
CLEANOUT
4" SEWER
CORPORATION STOP
8" SANITARY SEWER
MHU PAD
MHU PAD C
NEAREST TO PAD CENTERLINE
STUBS IN BACK HALF OF MHU PAD
LOCATE WATER AND SANITARY SEWER
PLACEMENT
ELECTRICAL
SEE E-501 FOR
4" SEWER SERVICE LINE
3" WATER MAIN
(INCLUDES SHUT OFF VALVE)
WATER CONNECTOR
1" WATER SERVICE
3" WATER MAIN
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps a u t o t im e
ID
Sheet
/9 /2
A N
S I
D
X
X X /X
X /X
/9 /2
M E
M P
H
IS
D
IS
T R
IC
T
M E
M P
H
IS
T
E N
N E
S S
E E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
CU502
N .T .S
X X
X
X X
X
X X
X
T E
M P
O R
A R
Y H
O U
S
IN
G S
IT
E
X
S E
R V
IC
E D
E T
A
IL
S
F E
M A -D
R -4
-L
A
B.
A.
2.
RATED PIPE MEETING AWWA STANDARDS.
PIPE SHALL BE WATER WORKS GRADE 150 PSI PRESSURE
PERPENDICULAR TO THE WATER MAIN. THE CARRIER
ON BOTH SIDES OF THE CROSSING, MEASURED
A WATER TIGHT CARRIER PIPE WHICH EXTENDS 10 FEET
ENCASE EITHER THE WATER MAIN OR THE SEWER LINE IN
ENSURE WATER TIGHTNESS.
TESTED TO A MINIMUM OF 25 PSI TO
STANDARDS AND SHALL BE PRESSURE
PRESSURE RATED PIPE MEETING AWWA
BE WATER WORKS GRADE 150 PSI (1.0 MPA)
THE SEWER MATERIALS SHALL
CONSTRUCTED:
DISTANCES,ONE OF THE FOLLOWING METHODS MUST BE
MINIMUM SPECIFIED SEPARATION
WHEN IT IS IMPOSSIBLE TO OBTAIN THE
ii.
i.
C.
1.
REQUIRED.
SUPPORT FOR THE WATER AND SEWER PIPES MAY BE
FROM THE SEWER AS POSSIBLE. SPECIAL STRUCTURAL
SHALL BE LOCATED SO BOTH JOINTS WILL BE AS FAR
AT CROSSINGS, ONE FULL LENGTH OF WATER PIPE
LOCATED ABOVE THE SEWER.
THE SEWER WITH PREFERENCE TO THE WATER MAIN
WHERE THE WATER MAIN IS EITHER ABOVE OR BELOW
OUTSIDE OF THE SEWER. THIS SHALL BE THE CASE
BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE
PROVIDE A MINIMUM VERTICAL DISTANCE OF 18 INCHES
WATER MAINS CROSSING SEWERS SHALL BE LAID TO
WHERE WATER MAINS AND SEWER MAINS CROSS:
COR ON SITE.
LAYOUT PLANS AND CONFIRMED/REVISED BY THE
EXACT LOCATION OF UNITS TO BE AS SHOWN ON THE
NOTES:
40'10'0 20'
PAD
BACK HALF OF PAD, A MINIMUM OF 7' IN FROM EDGE OF
5. WATER AND SEWER TO BE ROUGHLY CENTERED ON
4. WATER AND SEWER CONNECTION TO UNITS BY OTHERS.
NOTES:
D
E W
L
UTILITY SERVICE LOCATION
UNITS BY OTHERS.
1. WATER & SEWER CONNECTION TO
B A
T O
N R
O U
G E L
O U
IS
IA
N A
TYPICAL UTILITY LAYOUT
DETAIL
V
IC
T O
R
C U
.d g n
E B
R V
IC
T O
R
IA
N O
V
2 2
D
R A
W
IN
G R
E V
IS
E D W
IT
H R
E V
IS
IO
N N
O
File details come from the government source that posted it. Updated .