Amendment__0007_HHD_KI1_AND_KI2__17R0006.pdf
PDF 5 MB Posted
- Solicitation number
- W912EP-17-R-0006
About this file
Amendment 0007 for HHD KI1 and KI2
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
SF 30 CONTINUATION SHEET
Herbert Hoover Dike Rehabilitation Structure Replacements S-265 (KI-2) and S-266 (KI-1) Reconstruction, Okeechobee County, FLORIDA Amendment 7
SUMMARY OF CHANGES
1. SPECIFICATIONS:
In Volume 2 sections, the text changes have been updated with additions noted by underlined text and deletions noted by line/cross-outs, and pertain only to changes made by this amendment. The entire section is replaced if there is any change. The Project Table of Contents and Submittal Register are replaced without underlines and cross-outs if there are changes to these documents.
Changes to Specifications:
Volume 2 of 2 – Technical Specifications:
Add Acoustic Survey Protocol for the Florida Bonneted Bat to Sec. 01 57 20 as an attachment.
2. DRAWINGS:
S-266 (KI-1) RECONSTRUCTION
DELETE Drawing No. E-05 and REPLACE with the attached revised Drawing No. E-05.
DELETE Drawing No. E-06 and REPLACE with the attached revised Drawing No. E-06.
DELETE Drawing No. E-07 and REPLACE with the attached revised Drawing No. E-07.
DELETE Drawing No. E-08 and REPLACE with the attached revised Drawing No. E-08.
DELETE Drawing No. E-12 and REPLACE with the attached revised Drawing No. E-12.
DELETE Drawing No. E-13 and REPLACE with the attached revised Drawing No. E-13.
DELETE Drawing No. T-03 and REPLACE with the attached revised Drawing No. T-03.
S-266 (KI-2) RECONSTRUCTION
DELETE Drawing No. E-05 and REPLACE with the attached revised Drawing No. E-05.
DELETE Drawing No. E-06 and REPLACE with the attached revised Drawing No. E-06.
DELETE Drawing No. E-07 and REPLACE with the attached revised Drawing No. E-07.
DELETE Drawing No. E-08 and REPLACE with the attached revised Drawing No. E-08.
DELETE Drawing No. E-12 and REPLACE with the attached revised Drawing No. E-12.
DELETE Drawing No. E-13 and REPLACE with the attached revised Drawing No. E-13.
DELETE Drawing No. T-03 and REPLACE with the attached revised Drawing No. T-03.
(End of Summary of Changes)
Acoustic Survey Protocol for the Florida Bonneted Bat August 2014
The purpose of this survey is to document if Florida bonneted bats have a reasonable likelihood of using a proposed project site. The results of the surveys will provide information that can help guide the consultation process and appropriate conservation measures. Because of the difficulty in detecting this species, negative survey results will not equate to species absence. This protocol is designed to be implemented prior to potential impacts from construction or development projects. Because the Florida bonneted bat Consultation and Focal Area (Appendix A) was developed around confirmed Florida bonneted bat detections, an agency or applicant may choose to assume presence of Florida bonneted bats rather than implement acoustic surveys. Acoustical methods have been selected over mist netting as the primary survey methodology because this species flies and primarily forages at heights of 9 m (30 ft) or more; for this reason the species can be difficult to capture in mist nets.
The South Florida Ecological Services Field Office (Service) is available to review survey plans for the Florida bonneted bat and can provide recommendations on appropriate placement of bat detectors. Survey plans should include a map/aerial photo identifying the proposed project area boundaries, suitable bat habitat and acreages within the proposed project area, and the proposed number and tentative locations of acoustic monitoring sites.
TIMING:
Year-round: Acoustic surveys can be conducted in all months of the year, provided the minimum temperature stays above 60 degrees throughout the night.
SURVEY PERIOD:
Sunset-Sunrise - The acoustic sampling period for each sampling night begins at sunset and ends at sunrise for each detector. Sunset tables for the location of survey can be found at:
http://aa.usno.navy.mil/data/docs/RS_OneYear.php
SURVEY EFFORT: The following will be considered the minimum level of survey effort.
• To determine the acoustic survey effort, quantify the amount of suitable habitat1 within the proposed project area.
• The number of acoustic survey sites required for a project will be dependent upon the overall acreage of suitable habitat in the proposed project site.
• Detectors should be placed adjacent to features known to attract bats, such as water features, or within active or historic red-cockaded woodpecker clusters.
• Once a Florida bonneted bat has been detected, surveys of the proposed project area can be discontinued because presence of the species has been established.
1 Roosting habitat includes forest and other areas with large or mature trees or other areas with suitable roost structures.
Natural roosting structure primarily includes mature or large live or dead trees, tree snags, and trees with cavities, hollows, or crevices. Forest is defined as all types (all age classes) including: pine flatwoods, scrubby flatwoods, pine rocklands, royal palm hammocks, mixed or hardwood hammocks, cypress, sand pine scrub, or other forest types.
Foraging habitat includes open fresh water and permanent or seasonal freshwater wetlands (which provide sources of drinking water and prey), wetland and upland forests, open freshwater wetlands, wetland and upland shrub (which provide a prey base and suitable foraging conditions [i.e., open habitat structure]). Natural or semi-natural habitat patches in urban or residential areas may also provide foraging habitat.
http://aa.usno.navy.mil/data/docs/RS_OneYear.php
Linear projects: Linear projects are defined as roadways, transmission lines, etc. 5 detector nights per km (0.6 miles) of suitable habitat are required. Detectors should be distributed along the linear feature. Detectors can be moved to multiple locations within each kilometer surveyed but must remain in a single location throughout any given night. Detectors should not be placed closer than 200 meters apart.
Non-linear projects: A minimum of 16 detector nights per 20 acres of suitable habitat are required. If multiple detectors are used they should be placed a minimum of 200 meters apart. Projects less than 20 acres should still sample for a minimum of 16 nights
DETECTOR TYPE
Detectors suitable for use in this survey protocol include:
• Full-spectrum and/or zero-crossing detectors.
• Directional and omni-directional microphones.
• Microphones attached to detectors via a cable permitting that the cable length does not exceed manufacturer recommendations.
• Microphones should be mounted on grounded or metal poles to avoid build-up of electrostatic charges that may interfere with acoustic sampling.
DETECTOR PLACEMENT
Detector/Microphone placement is critical to the successful isolation of high-quality bat call sequences for later analysis. Accurate GPS coordinates must be generated and reported for each acoustic survey site. We recommend selecting deployment locations in consultation with the Service.
The following locations are likely to be suitable sites for detectors/microphones, including, but not limited to:
• forest-canopy openings
• near open water or vegetated wetlands
• wooded fence lines that are adjacent to large openings or connect two larger blocks of suitable habitat
• blocks of recently logged forest where some potential roost trees remain
• road and/or stream corridors with open tree canopies or canopy height of more than 10 m (33 ft)
• forest edges (Britzke et al. 2010)
Detectors/Microphones Deployment The following considerations address microphone height and directionality:
• at a minimum height of 5 m (16.4 ft); consider using vertical structures, when present, to establish greater height in detector/microphone placement;
• a minimum of 1.5 m (5 ft) in any direction from vegetation or other obstructions, and not under a tree canopy (Hayes 2000; Weller and Zabel 2002);
• in areas without, or with minimal2, vegetation within 10 m (33 ft) in front of the
2 If necessary, surveyors can remove small amounts of vegetation (e.g., small limbs, saplings) from the estimated microphone; and
• spaced a minimum of 200 m (656 ft) apart.
Orientation Detectors with directional microphones should be aimed 90 degrees above horizontal.
Weather Conditions At a minimum, nightly weather conditions for survey sites should be checked using the nearest NOAA National Weather Service station and summarized in the survey reports.
If any of the following weather conditions exist at a survey site during acoustic sampling, note the time and duration of such conditions, and repeat the acoustic sampling effort for that night.
• temperatures fall below 60°F during the night;
• precipitation, including rain and/or fog, that exceeds 30 minutes or continues intermittently during the night; and
• sustained wind speeds greater than 9 miles/hour (4 meters/second; 3 on Beaufort scale) during the night.
Verification of Proper Functioning Ensure acoustic detectors are functioning properly and conduct tests on microphone sensitivity to factory specifications before and after deployment, at a minimum. It is recommended that tests be conducted throughout the survey period.
SUBMISSION OF ACOUSTIC SURVEY RESULTS
Results of the acoustic surveys should be submitted to the Service using the data sheets and excel table provided, along with all raw data (i.e., zero crossing files, wave files and sonograms). In addition to the excel table, data sheets, and raw files, each acoustic survey report should include the following:
1. Description of the habitat within the proposed project area. Use Florida Land Use Cover and
Forms Classification System descriptions of habitat types.
2. Photographs of each acoustic site documenting: 1) the habitat in which the acoustic units were deployed; 2) the deployment location/position of the acoustic unit; 3) the orientation of the microphone at deployment.
3. Map identifying acoustic monitoring locations and a corresponding GPS coordinates.
4. Full names of all personnel conducting acoustic surveys, including those that selected acoustic sites and deployed detectors.
5. Description of acoustic detector brand(s) and model(s) used, microphone type, use of weatherproofing, acoustic monitoring equipment settings (e.g., sensitivity, audio and data detection cone at a site. Deployment of detectors/microphones in closed-canopy locations are acceptable as long as the area sampled below the canopy does not restrict the ability of the equipment’s detection cone to record high-quality calls (i.e., the vegetation is outside of the detection cone).
division ratios).
6. A description of how proper functioning of bat detectors was verified.
ADDITIONAL CONSIDERATIONS
Placement and Microphone Orientation Many features (e.g., vegetation, water, wind turbines, high-tensile power-lines, micro-wave towers) can reduce the quality of call sequences recorded in the field and impact the surveyor’s ability to record high-quality bat call sequences by causing calls to reflect off of these surfaces.
It is important to assess the volume and area of highest sensitivity within the zone of detection around the microphone to ensure the best detector/microphone placement and orientation. If detectors/microphones are placed in unsuitable locations, effective data analysis may be impossible, and the results of the sampling effort will likely be invalid.
Selection of acoustic sites is also important. Suitable set-up of the equipment should result in high-quality call sequences that are adequate for species identification. Modifications of the equipment (e.g., changing the orientation) at the same location on subsequent nights may improve quantity and quality of call sequences recorded, which can be determined through daily data downloads. If modifications of the equipment do not improve call identification, then the detectors will need to be moved to a new location.
Field Tests It is required to ensure equipment is working during set-up in the field. This can be done simply by producing ultrasound (e.g., finger rubs, calibrator, or follow the equipment manufacturer’s testing recommendations) in front of the microphone at survey start and survey finish. This documents that the equipment was working when deployed and when picked up (and by assumption throughout the entire period). Detector field settings (e.g., sensitivity, frequency, etc.) should follow the recommendations provided by the manufacturer. Surveyors should also save files produced by detectors (e.g., log files, status files, sensor files) as an excellent way to provide documentation when equipment was functioning within the survey period. Many types of detectors allow for setting timers that initiate and end recording sessions. This saves battery life as well as reducing the number of extraneous noise files recorded. However, if the units are visited when the timer is off, the surveyor cannot verify that the unit is functioning properly. This is particularly important in areas where no bat activity is recorded for the entire night or during the last portion of the night. In these cases, if the surveyor cannot demonstrate that the detector was indeed functioning properly throughout the survey period, then the site will need to be re-sampled unless adequate justification can be provided to the Service.
PERSONNEL
Acoustic surveyors should have either completed one or more of the available acoustic courses/workshops (e.g., Bat Conservation International, Bat Conservation and Management, AnaBat™) or be able to show similar on-the-job or academic experience. The proceeding workshops and course are all independently conducted and should be contacted directly; the Service is not affiliated with any of the workshops or courses and does not have additional information.
Acoustic surveyors should have a working knowledge of the acoustic equipment and Florida bonneted bat ecology. Surveyors should be able to identify appropriate detector placement sites and establish those sites in the areas that are most suitable for recording high-quality Florida bonneted bat calls.
Thus, it is highly recommended that all potential acoustic surveyors attend appropriate training and have experience in the proper placement of their field equipment.
Individuals qualified to conduct qualitative analysis of acoustic bat calls typically have experience:
(1) gathering known calls. This provides a valuable resource in understanding how bat calls change and the variation present in them; (2) identifying bat calls recorded in numerous habitat types; (3) familiarity with the species likely to be encountered within the project area; and (4) individuals must have multiple years of experience and must have stayed current with qualitative ID skills. A resume (or similar documentation) will be required to be submitted along with final survey reports for anyone making final qualitative identifications.
REFERENCES
Britzke, E.R, B.A. Slack, M.P. Armstrong, and S.C. Loeb. 2010. Effects of orientation and weatherproofing on the detection of bat echolocation calls. Journal of Fish and Wildlife Management 1(2):136-141.
Hayes, J. P. 2000. Assumption and practical considerations in the design and interpretation of echolocation-monitoring studies. Acta Chiropterologica 2:225-236.
Weller, T. J., and C. J. Zabel. 2002. Variation in bat detections due to detector orientation in a forest.
Wildlife Society Bulletin 30:922-930.
Addendum
INCLINOMETER NO.1
FLAP GATE
SC11
SC01
PC01
FC01
INCLINOMETER NO.2
FLAP GATE
SC12
PC12
CC12
SC22
GATE STRUCTURE
SC02
PC02
FC02
CC12
SC02
PC02
(TYP.)
SUPPORT
METAL CC11
SC01
PC01
PC31
SC01
PC01
PC02
GATE STRUCTURE
ACTUATOR NO. 1
SLIDE GATE
240V, 1PH
CC11
PC11
SC11
ACTUATOR NO. 2
SLIDE GATE
240V, 1PH
SPEC.
FINISH PER
SPARE 1"C, RECEPTACLE (TYP.)
STATION AND
FOR PUSH-BUTTON
NEMA 4X ENCLOSURE
HANDRAIL
(TYP OF 2)
PULL BOX
HANDRAIL
DISCONNECT (TYP.)
NEMA 4X NON-FUSED
SEE DWG E-03 AND E-04
GROUND LOOP
FROM CONTROL BUILDING
#2/0 BC GROUND CABLE
SPEC.
FINISH PER
SPARE 1"C,
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
RC11
RC12
SC01 PC01
SC11 PC11 CC11
SC21
P2
PC31
PC02SC02
CC12PC12SC12
SC22
PC03
CC13PC13
PC04
CC14PC14
PC05
CC15PC15
PC06
CC16PC16
PC32CC1
CC2 SC13 SC14 SC15 SC16
NOTES:
SCALE: N.T.S.
SCALE: N.T.S.
CONDUIT BLOCK DIAGRAM
KEY NOTES:
NOTES:
KEY NOTES:
AND INSTRUMENTATION WIRING CONDUITS.
2. USE SEPARATE PULL BOXES FOR POWER WIRING CONDUITS
GROUND LOOP. SEE GROUNDING DETAILS ON DWG E-10.
GROUND CABLE THAT CONNECTS TO CONTROL BUILDING
AND ALL OTHER EXPOSED METALS TO #2/0 AWG BC
SUPPORTS AND FRAMES, GATE EQUIPMENT, HANDRAILS,
1. BOND TO STRUCTURAL FOUNDATION (REBARS), METAL
LAKESIDE CULVERT GATE ELECTRICAL PLAN
"OR APPROVED EQUAL."
7. REFERENCED MANUFACTURERS SHALL BE CONSIDERED
MANUFACTURER'S WIRING DIAGRAM.
TO AVAILABLE SUTRON XPERT ANALOG I/O MODULE PER
6. CONNECT CONTROL BUILDING DOOR MAGNETIC CONTACT
OF SPECTRA CAMERA. SEE DRAWING T-07.
5. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATION
OF MOBOTIX CAMERAS. SEE DRAWING T-07.
4. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATIONS
EQUIPMENT PROVIDED.
3. THE CONTRACTOR SHALL COORDINATE DESIGN WITH
2. SEE DRAWING E-04 FOR NOTES AND CONTINUATION.
SEE DRAWINGS E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
"OR APPROVED EQUAL."
7. REFERENCED MANUFACTURERS SHALL BE CONSIDERED
MANUFACTURER'S WIRING DIAGRAM.
TO AVAILABLE SUTRON XPERT ANALOG I/O MODULE PER
6. CONNECT CONTROL BUILDING DOOR MAGNETIC CONTACT
OF SPECTRA CAMERA. SEE DRAWING T-07.
5. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATION
OF MOBOTIX CAMERAS. SEE DRAWING T-07.
4. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATIONS
EQUIPMENT PROVIDED.
3. THE CONTRACTOR SHALL COORDINATE DESIGN WITH
2. SEE DRAWING E-04 FOR NOTES AND CONTINUATION.
SEE DRAWINGS E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
ON DWG E-04
CONTINUED
N /A
N /A
-H
H D
R C
R K I1 -E
P .D
G N
/A
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
S H
E E
T
S T
R U
C T
U R
A L E
L E
C T
R
IC
A L P
L A
N
E-05
A
A
A
B /6
B
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -0
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
B
E-06
A
E-06
PA
PB
FOUNDATION (REBAR)
TO STRUCTURE
J. BOX
SENSOR
GATE
J. BOX
SENSOR
GATE
SENSOR
POSITION
GATE 2
DISC.
MOTOR
SENSOR
POSITION
GATE 1
DISC.
MOTOR
INCLINOMETER
FLAP GATE
GATE 1
INCLINOMETER
FLAP GATE
GATE 2
ACTUATOR
GATE 1
ACTUATOR
GATE 2
PANEL PP
STILLING WELL
LAKESIDE
STILLING WELL
LANDSIDE
DOOR MAGNETIC CONTACT
CONTROL BUILDING
SUTRON
HEAD AND TAIL STILL. WELLS
GATE 1 & 2 INCLINOMETERS
GATE 1 & 2 POS. SENSORS
2" CONDUIT, SC61 :
DISC.
MOTOR
DISC.
MOTOR
DISC.
MOTOR
SENSOR
POSITION
GATE 1A
ACTUATOR
GATE 1A
DISC.
MOTOR
SENSOR
POSITION
GATE 1B
ACTUATOR
GATE 1B
SENSOR
POSITION
GATE 2A
ACTUATOR
GATE 2A
SENSOR
POSITION
GATE 2B
ACTUATOR
GATE 2B
NIC
ACE-3600
CONTROL
LOCAL
STRUCTURE
LANDSIDE
CONTROL
LOCAL
STRUCTURE
LAKESIDE
ACTUATOR
SLIDE GATE
SC12
CONDUIT
FLEXIBLE
LIQUID-TIGHT
SC02
PC12
CC12
CONCRETE
TOP OF
SC22
NON-FUSED DISCONNECT
LOCKABLE NEMA 4X
AND HARDWARE
METAL STRUT
STAINLESS STEEL
5'-0" SUPPORT
ACTUATOR
SLIDE GATE
SC11
SUPPORT PLATE
SC21 NON-FUSED DISCONNECT
LOCKABLE NEMA 4X
AND HARDWARE
METAL STRUT
STAINLESS STEEL
5'-0" SUPPORT
PC31
CC11
CC12
CONCRETE
TOP OF
SC01
PC11
CC11
/4
FC02
PC02
PC01
CONDUIT
FLEXIBLE
LIQUID-TIGHT
BUILDING
FC01, TO CONTROL
CC1
GROUND LOOP
TO STRUCTURE
GROUND CABLE
#2/0 BC
GROUND LOOP
TO STRUCTURE
GROUND CABLE
#2/0 BC
SUPPORT PLATE
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
WITH EQUIPMENT PROVIDED
THE CONTRACTOR SHALL COORDINATE DESIGN
GENERAL NOTE:
KEY NOTES:
N /A
N /A
-H
H D
R C
R K I1 -E I3
.D
G N
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
D E
T A
IL
S
L A
K E
S
ID
E O
P E
R A
T
IN
G P
L A
T F
O R
M
E-06
A
A
A
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M M
E N
D M
E N
T N
O
D -6
D -2
A
STEEL, CONTINUOUS HINGE, NEMA 4X.
3. PLUGTRAB JUCTION BOX 8" X 6" X 4" STAINLESS
HAVE UL CERTIFICATION.
CERTIFIED UNDER UL508 AND PRODUCT SHALL
600V TYPE SIS. PANEL FABRICATOR SHALL BE
WIRING SHALL BE MINIMUM SIZE #14AWG
PANEL WITH PUSHBUTTONS AND GFI RECEPTACLE
HOFFMAN 304SS WITH PADLOCK FITTING AND INNER
2. STRUCTURE CONTROL AND OUTLET BOX 24"x 24"x 6", 240V DISCONNECT.
WITH AUXILIARY CONTACT HEAVY DUTY NEMA 4X, SS,
1. UNFUSED DISCONNECT. PROVIDE A 3 POLE, 30 AMP,
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -0
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
C
E-06 C
E-06
DOOR
DOOR
RECEPTACLE
STATION AND GFI
FOR PUSH-BUTTON
ENCL. 24"x24"x6"
LOCKABLE NEMA 4X
/8
B
E-05 SCALE: N.T.S.
SCALE: N.T.S.
A
E-05
SCALE: N.T.S.
C
E-06
DETAIL-TYPICAL POST BASE
SECTION - LAKESIDE GATE 1
SECTION - LAKESIDE GATES 2
A U
G U
S T
N /A
N /A
-H
H D
R C
R K I1 -E I6
.D
G N
N /A
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
L A
K E
S
ID
E C
O N
T R
O L S
C H
E M
A T
IC
E-07
B -2
A
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -0
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
LEGEND:
SUTRON GATE POSITION ACTUATOR
S-266
GATE 1
S-266
GATE 2
MC23 M023
OPERATOR 2
OPERATOR 1
HEATER
HEATER
NEUT
PNL PP
NEUT
PNL PP
MC13 M013
120VAC
PNL
1-1
1-35
STOP
OP1
LSC1 TSC1
TS01LS01
STOP
1-35
2-3
CL2
OP2
LSC2 TSC2
TS02LS02
G
M011
OL'S
OL
R Y
MC11
MC11
MO11
STARTER
REVERSING
MC21
M021
G
OL'S
OL
YR
1-2
NEUT
MC21
MO21
STARTER
REVERSING
SEE DRAWING E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
O.L. THERMAL OVERLOAD CONTACT WITH STARTER
SCALE: N.T.S.
GATE POSITION INDICATION CIRCUIT
SCALE: N.T.S.
DRIVE OPERATOR HEATER CIRCUITS
SCALE: N.T.S.
NOTE:
LOCAL CONTROL PANEL (SLCP)
STRUCTURE
LOCAL CONTROL PANEL
STRUCTURE
SLCP
SLCP
SLCP
SLCP SLCP
SLCP
MO21
MC21
CL1
MO11
MC11
LAKESIDE CONTROL PANEL SCHEMATIC
C11
C12
PP-1
PP-2/4
PP-3/5
PP-6
GATE 2 MOTOR
GATE 1 MOTOR
PP-7 INTERIOR RECEPTACLES
PP-10 LIGHTING
P1
P2 PANEL PP FEED
PORTABLE GENSET SERVICE
INTERIOR RECEPT.
GATE 2 MOTOR
7460 6720SUBTOTAL
TOTAL CONNECTED LOAD:
CONNECTED LOAD PHASE B:
CONNECTED LOAD PHASE A:
B
PHASE
A
PHASE
1 2
40 2
LIGHTING
GATE 1 MOTOR
MOUNTED: SURFACEAIC: 20,000
PANEL: PP
DESCRIPTION
CIRCUIT BREAKERS
DESCRIPTION
P O
L E
T R
IP
P O
L E
T R
IP
DESCRIPTION
NUMBER
CIRCUIT FROM TO
CABLE SIZE
ROUTING & REMARKS
NOTESCABLESCONDUCTORSTO
FROMFUNCTIONNUMBER
CONDUIT
SLC
SLC
PANEL PP
PANEL PP
PANEL PP
PANEL PP
PANEL PP
PANEL PP LIGHTS
RECEPTACLES
GATE 2 MOTOR
GATE 1 MOTOR
GATE HEATERS
GATE 2 ACTUATOR
GATE 1 ACTUATOR 10 #12 AWG & #12 GND
10 #12 AWG & #12 GND
2 #12 AWG & #12 GND
6 #8 AWG & #8 GND
6 #8 AWG & #8 GND
2 #10 AWG & #10 GND
2 #12 AWG & #12 GND
2 #12 AWG & #12 GND
" CONDUIT4
PC31
PP, PC02, MTR DS, PC12, ACTUATOR 2
PP, PC01, MTR DS, PC11, ACTUATOR 1
SLC, CC12, ACTUATOR 2
SLC, CC11, ACTUATOR 1
CC11
CC12
FC01
FC02
FC03
FC04
FC07
S01
S02
S21
STILLING WELL LEVEL SENSOR
STILLING WELL LEVEL SENSOR
GATE 1 POSITION SENSOR
GATE 2 POSITION SENSOR
PANEL PP
3 #1 AWG & #6 GND
3 #1 AWG & #6 GND
S11
S12
GATE 1 INCLINOMETERGATE 1 INCLINOMETER
GATE 1 ACTUATOR
GATE 2 ACTUATOR
SUTRON
SUTRON
SUTRON
SUTRON, RC11, STILLING WELL
SUTRON, RC12, STILLING WELL
SUTRON
SUTRON
2" CONDUIT
2" CONDUIT
CONTROL
CONTROL
11 #12 AWG
11 #12 AWG
C11
C12
POWER
POWER
POWER
POWER
1"
1"
SIGNAL
SIGNAL
S01
S02
SIGNAL
SIGNAL
GATE 1 ACTUATOR
GATE 2 ACTUATOR
GATE 1 ACTUATOR
GATE 2 ACTUATOR
GATE 1 POSITION SENSOR
GATE 2 POSITION SENSOR
POWER 2 #10 AWG & #10 GND
GATE 1 DISC SW/PUSH B
GATE 2 DISC SW/PUSH B
GATE 1 SENSOR J. BOX
GATE 2 SENSOR J. BOX
GATE 1 SENSOR J. BOX
GATE 2 SENSOR J. BOX
SIGNAL
SIGNAL
S11
S12
GATE 1 SENSOR J. BOX
GATE 2 SENSOR J. BOX
SIGNAL
SIGNAL S22
SUTRON
SUTRON
SUTRON
SUTRON
GATE 1 INCLINOMETER
GATE 2 INCLINOMETER
S11,S21
S12,S22
PANEL PP
PANEL PP
PANEL PP
GATE 1 DISC SW
GATE 2 DISC SW
GATE 1 DISC SW
GATE 2 DISC SW
PP-6
2"FUTURE SPAREPULL WIRE
2"FUTURE SPAREPULL WIREPULL BOX
PANEL PP
2"FUTURE SPAREPULL WIRESUTRON
2FUTURE SPAREPULL WIRESUTRON LAKESIDE STILLING WELL
FUTURE SPARESUTRON ANTENNA POLE 2" CAT5E, PULL WIRE
ANTENNA SUTRON ANTENNA POLE
"2
"2
"2
"2
PP-2/4, PP-1
PP-3/5, PP-1
PP-2/4, PP-1
PP-3/5, PP-1
"2
"2
3 #12 AWG, 7 #8 AWG
3 #12 AWG, 7 #8 AWG
1"
3 #12 AWG, 7 #8 AWG
3 #12 AWG, 7 #8 AWG
"2
"2
1"
1"
1"
1"
PC01
PC02
PC12
PC11
RC12
RC11
SC01
SC02
SC11
SC12
SC21
SC22
PC31
RC01
CABLE, CAT5E
LMR-400UF, GPS ANTENNA
2 LMR ANTENNA CABLE
GATE 2 INCLINOMETER
SUTRON, SC02, SNSR JB, SC22,
GATE 1 INCLINOMETER
SUTRON, SC01, SNSR JB, SC21,
GATE 2 POS. SEN.
SUTRON, SC02, SNSR JB, SC12,
GATE 1 POS. SEN.
SUTRON, SC01, SNSR JB, SC11,
40 2
40 2
27080
PANEL SCHEDULE
CIRCUIT SCHEDULE
CONDUIT SCHEDULE
C
IR
C
IR
LOAD
VOLT-AMP
LOAD
VOLT-AMP
B
PHASE
A
PHASE
SIZE
CONDUIT
NOTES:
LAKESIDE STILLING WELL
LAKESIDE STILLING WELL
LANDSIDE STILLING WELL
LAKESIDE STILLING WELL
MAINS: 150A MAIN BREAKER
FC08 FUTURE 2"PANEL PP PULL WIRE SPARE
14595 12480
20 1 19 20
60 2 21 22 20 1
23 24
TVSS
SPACE25 26
SPACE27 28
SPACE
SPARE
SPACE
29 30
DUAL GATE 1A
DUAL GATE 1B
DUAL GATE 2A
DUAL GATE 2B
LAKESIDE EQUIP. HEATERS
LANDSIDE EQUIP. HEATERS 600
LAKESIDE SLCP & RECEPT
LANDSIDE SLCP & RECEPT360
1920 1920
20 1
20 1
C13
C14
SLC
SLC
10 #12 AWG & #12 GND
10 #12 AWG & #12 GND SLC, CC14, ACTUATOR 1B
SLC, CC13, ACTUATOR 1A
C15
C16
SLC
SLC
10 #12 AWG & #12 GND
10 #12 AWG & #12 GND SLC, CC16, ACTUATOR 2B
SLC, CC15, ACTUATOR 2A
GATE 1 CONTROLS
GATE 2 CONTROLS
GATE 1A CONTROLS
GATE 1B CONTROLS
GATE 2A CONTROLS
GATE 2B CONTROLS
GATE 1A ACTUATOR
GATE 1B ACTUATOR
GATE 2A ACTUATOR
GATE 2B ACTUATOR
PANEL PP GATE HEATERS 2 #12 AWG & #12 GND
LAKESIDE EQUIP. HEATER
LANDSIDE EQUIP. HEATERPP-19
PP, PC01, MTR DS, PC11, ACTUATOR 1 & 2
PP, PC01, MTR DS, PC12, ACTR 1A,1B, 2A & 2B
LAKESIDE SLCP & RECEP LAKESIDE SLCP
PANEL PP 2 #10 AWG & #10 GND PC32LANDSIDE SLCP & RECEP LANDSIDE SLCPPP-22
PANEL PP
PANEL PP
6 #8 AWG & #8 GND
6 #8 AWG & #8 GND
PP-11/13 GATE 2A MOTOR GATE 2A MOTOR PP, PC05, MTR DS, PC15, ACTUATOR 2A
PP-12/14 GATE 1A MOTOR GATE 1A MOTOR PP, PC03, MTR DS, PC13, ACTUATOR 1A
PANEL PP 6 #8 AWG & #8 GNDPP-15/17 GATE 2B MOTOR GATE 2B MOTOR PP, PC06, MTR DS, PC16, ACTUATOR 2B
PANEL PP 6 #8 AWG & #8 GNDPP-16/18 GATE 1B MOTOR GATE 1B MOTOR PP, PC04, MTR DS, PC14, ACTUATOR 1B
CC13 CONTROL 11 #12 AWG C13GATE 1A ACTUATORGATE 1A DISC SW/PUSH B "2
CC14 CONTROL 11 #12 AWG C14GATE 1B ACTUATORGATE 1B DISC SW/PUSH B "2
CC15 CONTROL 11 #12 AWG C15GATE 2A ACTUATORGATE 2A DISC SW/PUSH B "2
CC16 CONTROL 11 #12 AWG C16GATE 2B ACTUATORGATE 2B DISC SW/PUSH B "2
FC09 FUTURE 2"ACE 3600 LANDSIDE SLCP PULL WIRE SPARE
PLUG BOX
S22 GATE 2 INCLINOMETERGATE 2 INCLINOMETER SUTRON
POWER PANEL PP "2
11 3 #12 AWG, 7 #8 AWGPC03 GATE 1A DISC SW PP-12/14, PP-19
POWER PANEL PP 3 #12 AWG, 7 #8 AWGPC04 GATE 1B DISC SW PP-16/18, PP-19
POWER PANEL PP 3 #12 AWG, 7 #8 AWGPC05 PP-11/13, PP-19
POWER PANEL PP 3 #12 AWG, 7 #8 AWGPC06 GATE 2B DISC SW PP-15/17, PP-19
GATE 2A DISC SW
"2
"2
"2
POWER "2
11 3 #12 AWG, 7 #8 AWGPC13 GATE 1A DISC SW PP-12/14, PP-19
POWER 3 #12 AWG, 7 #8 AWGPC14 GATE 1B DISC SW PP-16/18, PP-19
POWER 3 #12 AWG, 7 #8 AWGPC15 PP-11/13, PP-19
POWER 3 #12 AWG, 7 #8 AWGPC16 GATE 2B DISC SW PP-15/17, PP-19
GATE 2A DISC SW
"2
"2
"2
GATE 1A ACTUATOR
GATE 1B ACTUATOR
GATE 2A ACTUATOR
GATE 2B ACTUATOR
LAKESIDE SLCP
POWER 2 #10 AWG & #10 GNDPANEL PP 1"PC32 LANDSIDE SLCP PP-22
4 - 2"
SIGNAL S131"SC13
SC14
SC15
SC16
SIGNAL
SIGNAL
SIGNAL
ACE 3600 GATE 1A POSITION SENSOR
S13 GATE 1A ACTUATOR
S14
S15
S16
ACE 3600
ACE 3600
ACE 3600
ACE 3600
GATE 1A POSITION SENSOR
GATE 1A POS. SEN.
ACE-3600, SC03, SC13,
GATE 1B POSITION SENSOR GATE 1B ACTUATOR
GATE 1B POS. SEN.
ACE-3600, SC04, SC14,
GATE 2A POS. SEN.
ACE-3600, SC05, SC15,
GATE 2B POS. SEN.
ACE-3600, SC06, SC16,
GATE 2A POSITION SENSOR
GATE 2B POSITION SENSOR
GATE 2A ACTUATOR
GATE 2B ACTUATOR
S21
ACE 3600
ACE 3600
ACE 3600
S141"GATE 1A POSITION SENSOR
S151"GATE 2A POSITION SENSOR
S161"GATE 2B POSITION SENSOR
CC2 CONTROL ACE-3600 2" PULL WIRE FUTURELANDSIDE SLCP
SC61 SIGNAL SUTRON ACE-3600 2" SEE NOTE 3
LANDSIDE SLCP
LAKESIDE SLCP
LANDSIDE STILLING WELL
LAKESIDE GATE 2 DISC SW
CC1 CONTROL ACE-3600 2" PULL WIRE FUTURELAKESIDE SLCP
TYP: NEMA 1
SERVICE:
0 SPARE
0 SPARE
SPACE
SAFETY SWITCH
SAFETY SWITCH
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
2 - BELDEN #1049A
BELDEN #1049A
2 - BELDEN #1049A
BELDEN #1049A
BELDEN #1049A
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
SEE NOTE 4
N /A
N /A
-H
H D
R C
R K I1 -E I6
.D
G N
N /A
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
C O
N D
U
IT
A
N D C
IR
C U
IT
S
C H
E D
U L
E S
E-08
A/C RECEPT. 1100
PP-9 PANEL PPA/C RECEPTACLE A/C UNIT 2 #12 AWG & #12 GND " CONDUIT4
POSITION SENSOR PLUGTRAB JUNCTION BOX.
4. CONNECTION FROM ACE3600 RTU TO GATE POSITION SENSOR VIA GATE
STILLING WELLS IN 2" CONDUIT FOR MOTOROLA ACE-3600.
SENSORS, GATE 1 AND 2 INCLINOMETERS, AND HEADWATER AND TAILWATER
3. PROVIDE DUPLICATE ANALOG INPUTS (AI) FROM GATE 1 AND 2 POSITION
BE ATTACHED WITH SCREWS.
IDENTIFYING THE LOCATION OF THE MAIN BREAKER. NAMEPLATE SHALL
WHITE ON BLACK PHENOLIC NAMEPLATE WITH 1/2 INCH HIGH LETTERS
2. CONTRACTOR SHALL FURNISH AND INSTALL ON THE COVER OF THE PANEL,
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS, SEE DWG E-01.
A
A
D -2
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -0
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
ACTUATOR NO. 2A
BOTTOM GATE
240V, 1PH
ACTUATOR NO. 2B
BOTTOM GATE
240V, 1PH
ACTUATOR NO. 1A
BOTTOM GATE
240V, 1PH
ACTUATOR NO. 1B
BOTTOM GATE
240V, 1PH
PC05
PC06
SC15
SC16
CC16
CC15
PC03
PC04
PC32
SC14
CC2
SC13
CC15
PC15
SC15
CC16
PC16
SC16
CC13
PC13
SC13
CC14
PC14
SC14
CABLE
GROUND
# 2/0 BC
DWG E-03 AND E-04
GROUND LOOP. SEE
FROM CONTROL BUILDING
# 2/0 BC GROUND CABLE
GATE STRUCTURE
GATE STRUCTURE
RECEPTACLE
STATION &
PUSH-BUTTON
ENCLOSURE FOR
NEMA4X
DISC.
NEMA4X
DISC.
NEMA4X
DISC.
NEMA4XDISC.
NEMA4X
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
NOTES:
KEY NOTES:
SCALE: N.T.S.
LANDSIDE CULVERT GATE ELECTRICAL PLAN
INSTRUMENTATION WIRING.
2. PROVIDE SEPARATE PULL BOXES FOR POWER WIRING AND
ON DRAWING E-10.
TO CONTROL BUILDING GROUND LOOP. SEE GROUNDING DETAILS
EXPOSED METALS TO #2/0 AWG BC GROUND CABLE THAT CONNECTS
AND FRAMES, GATE EQUIPMENT, HANDRAILS, AND ALL OTHER
1. BOND TO STRUCTURAL FOUNDATION (REBARS), METAL SUPPORTS
"OR APPROVED EQUAL."
7. REFERENCED MANUFACTURERS SHALL BE CONSIDERED
MANUFACTURER'S WIRING DIAGRAM.
TO AVAILABLE SUTRON XPERT ANALOG I/O MODULE PER
6. CONNECT CONTROL BUILDING DOOR MAGNETIC CONTACT
OF SPECTRA CAMERA. SEE DRAWING T-07.
5. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATION
OF MOBOTIX CAMERAS. SEE DRAWING T-07.
4. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATIONS
EQUIPMENT PROVIDED.
3. THE CONTRACTOR SHALL COORDINATE DESIGN WITH
2. SEE DRAWING E-04 FOR NOTES AND CONTINUATION.
SEE DRAWINGS E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
A U
G U
S T
N /A
N /A
-H
H D
R C
R K I1 -E
P .D
G N
N A
N /A
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
L A
N D
S
ID
E C
U L
V E
R T G
A T
E E
L E
C T
R
IC
A L P
L A
N
E-12
1 1
PC
PD
B
E-13
A
E-13
D W
G N
O E -0
C O
N T
IN
U E
D
HANDRAILS
CONNECT TO
HANDRAILS
CONNECT TO
FOUNDATION (REBARS)
TO STRUCTURE
A A
A
D -5
D -8
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -1
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
SUPPORT PLATE SUPPORT PLATE
TOP OF CONCRETE
ACTUATOR
NO. 1A
BOTTOM GATE
SC13
PC13
CC13
CC16
CC15
CC13
CC14
PC32
FC04
AND HARDWARE
METAL STRUCT
STAINLESS STEEL
5'-0" SUPPORT
NON-FUSED DISCONNECT
LOCKABLE NEMA 4X
PC06
CC16
PC16
SC16
SC15
PC15
CC15
ACTUATOR
NO. 2A
BOTTOM GATE
TOP OF CONCRETE
AND HARDWARE
METAL STRUCT
STAINLESS STEEL
5'-0" SUPPORT
SC14
PC14
CC14
FLEXIBLE CONDUIT
LIQUID-TIGHT FLEXIBLE CONDUIT
LIQUID-TIGHT
CC2
BUILDING
FC03, TO CONTROL
GROUND LOOP
TO STRUCTURE
#2/0 BC GROUND CABLE
ACTUATOR
NO. 1 B
WEIR GATE
DISCONNECT
NON-FUSED
LOCKABLE NEMA 4X
PC03 PC04
NON-FUSED DISCONNECT
LOCKABLE NEMA 4X
ACTUATOR
NO. 2B
WEIR GATE
DISCONNECT
NON-FUSED
LOCKABLE NEMA 4X
PC05
GROUND LOOP
TO STRUCTURE
#2/0 BC GROUND CABLE
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
JUNCTION BOX
PLUGTRAB
GATE SENSOR
E-13
E L E
C T
R
IC
A L
L A
N D
S
ID
E O
P E
R A
T
IN
G P
L A
T F
O R
M
D E
T A
IL
S
J .D .H
S .J .P
-H
H D
R C
R K I1 -E I3
DOOR DOOR DOOR DOOR
SCALE: N.T.S.E-12
A
SCALE: N.T.S.E-12
B
C
E-06
C
E-06
SECTION - LANDSIDE GATES 2A AND 2B SECTION - LANDSIDE GATES 1A AND 1B
V .L
WITH EQUIPMENT PROVIDED
THE CONTRACTOR SHALL COORDINATE DESIGN
GENERAL NOTE:
KEY NOTES:
RECEPTACLE
STATION AND GFI
FOR PUSH-BUTTON
ENCL. 36" W X 24" H X 6" D
LOCKABLE NEMA 4X
A
C /D -1 /2
B /C -5 /8
A
A
A
A
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
3. PLUGTRAB JUNCTION BOX 8" X 6" X 4", STAINLESS
HAVE UL CERTIFICATION.
CERTIFIED UNDER UL508 AND PRODUCT SHALL
600V TYPE SIS. PANEL FABRICATOR SHALL BE
WIRING SHALL BE MINIMUM SIZE #14AWG
PANEL WITH PUSHBUTTONS AND GFI RECEPTACLE
HOFFMAN 304SS WITH PADLOCK FITTING AND INNER
2. STRUCTURE CONTROL AND OUTLET BOX 36" W x 24" H x 6" D, STAINLESS STEEL, 240V DISCONNECT.
WITH AUXILIARY CONTACT HEAVY DUTY NEMA 4X,
1. UNFUSED DISCONNECT. PROVIDE A 3 POLE, 30 AMP,
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
E le c tr ic a l\ E -1
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
1 1
3 3 33
V .L
V .L
NOTES:
T-03
T S .D
G N
-H
H D
R C
R K I1
T E
L E
C O
M M
U N
IC
A T
IO
S
J .D .H
S .J .P
S U
T R
O N S
Y S
T E
M C
O M
P O
N E
N
APPROVED EQUAL."
AND 6F SHALL BE MANUFACTURERS AS SHOWN "OR
2. REFERENCED ITEMS: 1A THRU 2M, 3D, 3J, 5A, 5C, 6A, 6B, 6E,
SUPPRESSION SHALL DISSIPATE 3,000 W/PAIR.
SURGE SUPPRESSION SHALL MEET UL 497B. SURGE
1. PROVIDE SURGE SUPPRESSION FOR ANTENNA CABLES.
A
B -3 /4
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
3C
3G
3E
BATTERY BOX
1"-WIRING DUCT
1-1/2" WIRING DUCT
iNET-II 900
GE
iNET-II 900
GE
CRADLEPOINT
MANUFACTURER DESCRIPTION
PART
1-1/2"x1-1/2" WIREWAY
1-1/2" WIREWAY COVER
DIN RAIL
TERMINAL BLOCK
TERMINAL BLOCK END COVER
END CLAMPS
TERMINAL STRIP MARKER
MEASUREMENT AND CONTROL MODULE (DATA LOGGER)
F1.5X1.5LG6
C1.5LG6
08 01 73 3
30 04 36 2
HOFFMAN
PANDUIT
PHOENIX CONTACT
PHOENIX CONTACT
1C
1D
1E
2C
2B
2A
3A
2G
2E
2D
5B
5A
5C
PANDUIT
PHOENIX CONTACT
PHOENIX CONTACT
BURNDY
PHOENIX CONTACT
KC17B1
30 03 02 0
08 00 88 6
08 00 30 7
2F
TYPE SP SERVICE GRD POST CONNECTOR
PHOENIX CONTACT 55 31 72 3 10AMP CIRCUIT BREAKER-1 POLE
30 04 03 2 KNIFE DISCONNECTPHOENIX CONTACT
5D
3/8" DIA. X 1" LONG HYDROPHOBIC FILTER MATERIAL
PRODUCTS #5541
INTERSTATE SPECIALTY
GALVANIZED STEEL CORD GRIP FOR 3/8" CORDCGFP1931B CROUSE HINDS
POREX
3D
3E
3F
2H PHOENIX CONTACT 13 02 21 5 PARTITION PLATE
2I PHOENIX CONTACT 02 03 25 0 FIXED BRIDGE
1F
A-30P24 BACK PANELHOFFMAN1G
3G
4A
4B
4C SUTRON
4D
6411-11624E
6411-15614F
SUTRON
N1186-B DUAL RATED GROUND BARILSCO1H
PANDUIT
1I
1J
PANDUIT 1"x1" WIREWAY
1" WIREWAY COVER
F1X1LG6
C1LG6
3B
SUTRON
SUTRON SATLINK-2 TRANSMITTER
MORNINGSTAR
SUTRON 5000-0081 YAGI GOES SATELLITE ANTENNA
SUTRON 5000-0170 JAM RESISTANT GPS ANTENNA
8111-1113-1 RF COAX LIGHTNING PROTECTOR
LIGHTNING PROTECTORN/A N/A
SUTRON ANTENNA CABLE
SUTRON ANTENNA CABLE
XPERT2
2J
3H N/A N/A GATE POSITION INDICATOR IN GATE ACTUATOR
SUTRON STILLING WELL SDI-12 SHAFT ENCODER
APPLIED GEOMECHANICS
3K N/A N/A
3I
3J
SUTRON ANALOG I/O MODULE
SDI-12 TERMINATION
PHOENIX CONTACT
PHOENIX CONTACT
2K
2L
2M
PHOENIX CONTACT
PHOENIX CONTACT
28 56 12 6 PLUGTRAB BASE
28 58 04 3 PLUGTRAB PLUG
28 56 11 3 PLUGTRAB BASE
28 56 03 2 PLUGTRAB PLUG
1A
56-0540
GE GE iNET-II 900 GE iNET-II 900 RADIO OR APPROVED EQUAL
N/A
PHOENIX CONTACT
PHOENIX CONTACT
8080-0003
A604816SSLP, ADP2
SOLAR CONTROLLER
GATE POSITION INDICATOR IN GATE ACTUATOR
TOYO BATTERY CO.
5E
6A N/A 3.5AMP CIRCUIT BREAKER-1 POLE
6B
6C
6D
6E A-VK33
6F
09 15 06 9 10 AMP CIRCUIT BKR - 2 POLE W/ AUX CONTACTS
FURNISHED BY CONTRACTOR N/A 4 COND, #14 AWG SIS CONDUCTORS
FURNISHED BY CONTRACTOR N/A 6 COND, #14 AWG SIS CONDUCTORS
HOFFMAN 4" X 4" LOUVER WITH FILTER
WIEGMANN RSC161610 16" X 16" X 10" NEMA 3R ENCLOSURE
N/A N/A
BP SOLAR BP 350
N/A
5F
50 WATT SOLAR PANELS
12 VOLT 55 AH BATTERIES
SOLAR PANEL ROOF MOUNTING BRACKET
A906-ST-BN-V
N/A
DOOR POCKET, POWDER COAT EXTERIOR WHITE
48H"x36W"x12D" STAINLESS STEEL ENCLOSURE WITH INTERIOR
SS-10L
6GFM55
N/A AC QUAD RECEPTACLE
3C SUTRON 6461-1242 POWER TERMINATION
POWER SONIC PSC-12800A POWER SUPPLY
CRADLEPOINT AER1600LP6-NA-M CRADLEPOINT AER1600LP6 OR APPROVED EQUAL
6G
6461-1242-1
REF
SUTRON SYSTEM COMPONENTS
CLOSE NIPPLE
1/2" RIGID
SCALE: N.T.S.
SUTRON ENCLOSURE LAYOUT
3F
5F
3A
3B
1J1I
4C
3D
2A
5A
4D 4D 4D 4C
1H
4C
2D
6A 2C 2C 2C 2I
2C
1B 1F1C1B
6D
1D 1E
2B
2B
2F 2B
2D 2G
CLOSE NIPPLE
1/2" RIGID
6A
2F
5F
SELECT
FLOODED
OR
SEALED
DISCONNECT
LOAD
BATTERY
FLOODED
WIRE FOR
JUMPER
REMOVE
APPLIED GEOMECHANICS INCLINOMETER OR APPROVED EQUAL
XPERT
SUTRON
000 00
1I 1J
2C
2F 2F
2H
2B 2B
1I 1J2L 2M
2F
2J 2K
6G
POWER SONIC
P H
O E
N
IX
C
O N
T A
C T S
P T
X
F -B
E
P T -H
F -1
D
C -S
T
P H
O E
N
IX
C
O N
T A
C T S
P T
X
F -B
E
P T -H
F -1
D
C -S
T
P H
O E
N
IX
C
O N
T A
C T S
P T
X -2
D
C -S
T
P T
X -B
E
P H
O E
N
IX
C
O N
T A
C T S
P T
X -2
D
C -S
T
P T
X -B
E
P H
O E
N
IX
C
O N
T A
C T S
P T
X -2
D
C -S
T
P T
X -B
E
P H
O E
N
IX
C
O N
T A
C T S
P T
X -2
D
C -S
T
P T
X -B
E
S S
LOADSOLAR BATTERY
CHARGING
TEMP SENSE
MORNINGSTAR
PHOTOVOLTAIC CONTROLLER
12 VOLTS
6.5A SOLAR
6.0A LOAD
S A T L I N K 2
LOGGER - TRANSMITTER
100 - 300 - 1200 BPS
WARNING!
Operation of this transmitter must be with permission and assignment of the U.S. Dept.
Transmitter Power w/recommended antennas: 100 / 300 BPS - 8 Watts; 1200 BPS - 16 Watts of Commerce NOAA/NESDIS and must not exceed NESDIS permitted maximum uplink EIRP.
Recommend Antenna: Sutron 5000-0080 or -0081 YAGI Antenna
WWW.SUTRON.COM ISO 9001: 2000
-E
N D P
A N
E L
SUTRON
O U
T P
U T
R F
L E
D
T X F a u lt
S ta tu s
A N
T G
P S
R S
B U
C K
E T
T
IP
P
IN
G S
D I-
G n d B u c k e t
T ip p in g
V
G n d
D a ta
R E
S E
T F S
5D
CABLE ENTRANCE
FOR SOLAR PANEL
ENTRANCE
FOR ANTENNA CABLE
CABLE ENTRANCE
FOR RADIO ANTENNA
ENTRANCE
FOR ANTENNA CABLE
FAST CHARGE
CAUTION
Model PSC-12800
FAULT
Sealed Lead-Acid
Battery Charger
POWER / FLOAT
Class 2
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I1 P la n s \1
T e le c o m m u n ic a ti o n s \T -0
A m e n d
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
J A
N
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N
W E
P -1
-R -0
ACTUATOR NO. 1
SLIDE GATE
240V, 1PH
SC11
PC11
FC01
PC01
SCO1
(TYP OF 2)
PULL BOX
PC31
PC01
SC01
CC11
(TYP.)
SUPPORT
METAL
CC11
SC11
GATE STRUCTURE
DISCONNECT (TYP.)
NEMA 4X NON-FUSED
PC01
RECEPTACLE (TYP.)
STATION AND
FOR PUSH-BUTTON
NEMA 4X SLCP, ENCLOSURE
SC01
SPEC.
FINISH PER
SPARE 1"C,
HANDRAIL
SEE DWG E-03 AND E-04
GROUND LOOP
CONTROL BUILDING
CABLE FROM
#2/0 BC GROUND
(REBAR)
FOUNDATION
TO STRUCTURE
INCLINOMETER
FLAP GATE
JUNCTION BOX #1
PLUGTRAB
GATE SENSOR
RC11
RC12
SC01 PC01
SC11 PC11 CC11
SC21
P5
PC31
PC03
CC13PC13
PC04
CC14PC14
PC32CC1
CC2 SC13 SC14
NOTES:
SCALE: N.T.S.
CONDUIT BLOCK DIAGRAM
KEY NOTES:
NOTES:
KEY NOTES:
AND INSTRUMENTATION WIRING CONDUITS.
2. USE SEPARATE PULL BOXES FOR POWER WIRING CONDUITS
GROUND LOOP. SEE GROUNDING DETAILS ON DWG E-10.
GROUND CABLE THAT CONNECTS TO CONTROL BUILDING
AND ALL OTHER EXPOSED METALS TO #2/0 AWG BC
SUPPORTS AND FRAMES, GATE EQUIPMENT, HANDRAILS,
1. BOND TO STRUCTURAL FOUNDATION (REBARS), METAL
"OR APPROVED EQUAL."
7. REFERENCED MANUFACTURERS SHALL BE CONSIDERED
MANUFACTURER'S WIRING DIAGRAM.
TO AVAILABLE SUTRON XPERT ANALOG I/O MODULE PER
6. CONNECT CONTROL BUILDING DOOR MAGNETIC CONTACT
OF SPECTRA CAMERA. SEE DRAWING T-07.
5. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATION
OF MOBOTIX CAMERAS. SEE DRAWING T-07.
4. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATIONS
EQUIPMENT PROVIDED.
3. THE CONTRACTOR SHALL COORDINATE DESIGN WITH
2. SEE DRAWING E-04 FOR NOTES AND CONTINUATION.
SEE DRAWINGS E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
"OR APPROVED EQUAL."
7. REFERENCED MANUFACTURERS SHALL BE CONSIDERED
MANUFACTURER'S WIRING DIAGRAM.
TO AVAILABLE SUTRON XPERT ANALOG I/O MODULE PER
6. CONNECT CONTROL BUILDING DOOR MAGNETIC CONTACT
OF SPECTRA CAMERA. SEE DRAWING T-07.
5. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATION
OF MOBOTIX CAMERAS. SEE DRAWING T-07.
4. COORDINATE WITH FIELD OFFICE FOR PROPER LOCATIONS
EQUIPMENT PROVIDED.
3. THE CONTRACTOR SHALL COORDINATE DESIGN WITH
2. SEE DRAWING E-04 FOR NOTES AND CONTINUATION.
SEE DRAWINGS E-01 AND E-02.
1. FOR ELECTRICAL NOTES, LEGEND, AND ABBREVIATIONS,
A U
G U
S T
N /A
N /A
-H
H D
R C
R K I1 -E
P .D
G N
N A
N /A
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
S H
E E
T
S T
R U
C T
U R
A L E
L E
C T
R
IC
A L P
L A
N
E-05
SCALE: N.T.S.
LAKESIDE CULVERT GATE ELECTRICAL PLAN
FROM DWG E-04
CONTINUED
A
A
B /6
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I2 P la n s \1
E le c tr ic a l\ E -0
A m e n d
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N P
R O J E
C T
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
W E
P -1
-R -0
A
E-06
P
P
J. BOX
SENSOR
GATE
SENSOR
POSITION
GATE 1
DISC.
MOTOR
INCLINOMETER
FLAP GATE
GATE 1
ACTUATOR
GATE 1
PANEL PP
STILLING WELL
LAKESIDE
STILLING WELL
LANDSIDE
DOOR MAGNETIC CONTACT
CONTROL BUILDING
SUTRON
HEAD AND TAIL STILL. WELLS
GATE 1 & 2 INCLINOMETERS
GATE 1 & 2 POS. SENSORS
2" CONDUIT, SC61 :
DISC.
MOTOR
DISC.
MOTOR
SENSOR
POSITION
GATE 1A
ACTUATOR
GATE 1A
SENSOR
POSITION
GATE 1B
ACTUATOR
GATE 1B
NIC
ACE-3600
CONTROL
LOCAL
STRUCTURE
LANDSIDE
CONTROL
LOCAL
LAKESIDE
FC01, TO SHELTER
CONDUIT
FLEXIBLE
LIQUID-TIGHT
/4
AND HARDWARE
METAL STRUT
STAINLESS STEEL
5'-0" SUPPORT
SUPPORT PLATE
NON-FUSED DISCONNECT
LOCKABLE NEMA 4X
SC21
SC11
ACTUATOR
SLIDE GATE
SC01
PC11
CC11
CONCRETE
TOP OF
CC11
PC31
PC01
GROUND LOOP
TO STRUCTURE
GROUND CABLE
#2/0 BC
JUNCTION BOX
PLUGTRAB
GATE SENSOR
WITH EQUIPMENT PROVIDED
THE CONTRACTOR SHALL COORDINATE DESIGN
GENERAL NOTE:
KEY NOTES:
A U
G U
S T
N /A
N /A
-H
H D
R C
R K I2 -E I3
.D
G N
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
O P
E R
A T
IN
G P
L A
T F
O R
M D
E T
A
IL
S
E-06
A
A
R E
V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
C -4
-2
3. PLUGTRAB JUCTION BOX 8" X 6" X 4" STAINLESS
HAVE UL CERTIFICATION.
CERTIFIED UNDER UL508 AND PRODUCT SHALL
600V TYPE SIS. PANEL FABRICATOR SHALL BE
WIRING SHALL BE MINIMUM SIZE #14AWG
PANEL WITH PUSHBUTTONS AND GFI RECEPTACLE
HOFFMAN 304SS WITH PADLOCK FITTING AND INNER
2. STRUCTURE CONTROL AND OUTLET BOX 24"x 24"x 6", 240V DISCONNECT.
WITH AUXILIARY CONTACT HEAVY DUTY NEMA 4X, SS,
1. UNFUSED DISCONNECT. PROVIDE A 3 POLE, 30 AMP,
A
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O of Engineers
US Army Corps
Jacksonville District
DEPENDS ON YOU
SAFETY ON THIS JOB
DRAWING NO.
D E
S C
R
IP
T
IO
N N o
S Y
M Z
O N
E
J A
C K
S O
N V
IL
L E F
L O
R
ID
A
J A
C K
S O
N V
IL
L E D
IS
T R
R P
S O
F E
N G
IN
E E
R S
D E
P A
R T
M E
N T O
F T
H E A
R M
Y D
E S
IG
N E
D B
Y
N /A
N /A
A S S
H O
W N p w \C
O E -S
A J P
W P J
A X .s a j.
d s .u s a c e .a rm y .m il :S
A J P
W \D o c u m e n ts \C
S
F \H e rb e rt H o o v e r
D ik e R e h a b il it a ti o n \0
-C u lv e rt R e h a b il it a ti o n \S -2
K I1 a n d S -2
K I2 S -2
K I2 P la n s \1
E le c tr ic a l\ E -0
A m e n d
H E
R B
E R
T H
O O
V E
R D
IK
E R
E H
A B
IL
IT
A T
IO
N P
R O J E
C T
S T
R U
C T
U R
E R
E P
L A
C E
M E
N T
S -2
K I-
R E
C O
N S
T R
U C
T
IO
N J
O E R
W A
L L
IS
P .E
/2
/2
W E
P -1
-R -0
C
E-06
DOOR
DETAIL - TYPICAL POST BASE
SCALE: N.T.S.
C
E-06
SECTION - GATE 1
SCALE: N.T.S.
A
E-05
/8
1 2
(SLCP)
RECEPTACLE
STATION AND GFI
FOR PUSH-BUTTON
ENCL. 24"x24"x6"
LOCKABLE NEMA 4X
U
G U
S T
N /A
N /A
-H
H D
R C
R K I2 -E I6
.D
G N
J .D .H
V .L
S .J .P
E L E
C T
R
IC
A L
C O
N T
R O
L S
C H
E M
A T
IC
E-07
A
A -7
A R
E V
IS
E D T
O A
C C
O M
P A
N Y A
M E
N D
M E
N T N
O
A
B
C
D
1234567
D
C
B
A
8 7 6 5 4 3 2
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D R
A W
IN
G D
A T
E
F
IL
E N
U M
B E
R
S U
B M
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .