Amendment 0005 PLAN_SET_AMND-2020-02-19-0005.pdf

PDF 5 MB Posted

Attached to
Rock Island District Clock Tower Annex 2nd Floor Remodel
Solicitation number
W912EK20B0001
Issued by

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPROVAL RECOMMENDED BY:

APPROVED BY:

DISTRICT COMMANDER

DATE

DATE

DATE

DATE

DATEDATE

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

GEOTECHNICAL BRANCHCHIEF,

DESIGN BRANCHCHIEF,

TECHNICAL SERVICES BRANCHCHIEF,

ENGINEERING & CONSTRUCTION DIVISIONCHIEF,

HYDROLOGY & HYDRAULICS BRANCHCHIEF, OF ALL DRAWINGS IN THIS SET.

SIGNATURES INDICATE OFFICIAL RECOMMENDATION

EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.

DOCUMENTS WITHIN THE SCOPE OF THEIR

INDIVIDUALS APPEAR ON THESE PROJECT

SIGNATURES AND REGISTRATION DESIGNATIONS OF

DISTRICT CORPS OF ENGINEERS. THE INITIALS OR

THIS PROJECT WAS DESIGNED BY THE ROCK ISLAND

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

ID

Sheet

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

ROCK ISLAND DISTRICT CLOCK TOWER ANNEX

2nd FLOOR REMODEL

ROCK ISLAND ARSENAL, ROCK ISLAND, ILLINOIS

R O

C K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

E X

B

C L

K T

W R

N

D F

L O

O R R

E M

O D

E L

K H

E N

N E

M A

N B

C L

K T

W R

G -0

.d g n

G-001

ROCK ISLAND DISTRICT

C

V E

R S

H E

E T

P

M A

R K

S /2

/2

LANE E.INGRAM 02/13/2020

062-056679

DAVID L. MORITZ 02/13/2020

201171R

12-31-2020

C H

A M

B E

R L

IN

T-502, T-503

OF THE STATE OF MINNESOTA.

PROFESSIONAL ENGINEER UNDER THE LAWS

I HEREBY CERTIFY THAT THIS PLAN,

SIGNATURE:

OR PRINTED)

NAME:(TYPED

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

DATE: LICENSE #:

BRIAN T. BIMBERG

43212

PAGES OR SHEETS COVERED BY THIS SEAL:

11-30-2021

W912EK20B0001

W E

K

B

DECEMBER, 2019

OF ILLINOIS.

PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE

PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED

DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT

I HEREBY CERTIFY THAT REVISION TO THIS ENGINEERING

PAGES OR SHEETS COVERED BY THIS SEAL:

MY LICENSE RENEWAL DATE IS

LICENSE NUMBER:

PERSONAL SUPERVISION AND THAT I AM A BICS1 ACCREDIATED

DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT

I HEREBY CERTIFY THAT REVISION TO THIS ENGINEERING

PAGES OR SHEETS COVERED BY THIS SEAL:

MY LICENSE RENEWAL DATE IS

LICENSE NUMBER:

02/13/2020

M-601

E-001, E-003, E-101, E-102

L I

/1

/2

A D

M

A

S I

D

D G

N S

P E

C

S

Y T

IM

E a u to u s e rn a m e

D

A T

E

C K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

E X

N

D F

L O

O R R

E M

O D

E L

M-601

B

C L

K T

W R

M -6

.d g n

B

C L

K T

W R

.B

IM

B U

R G

M E

C H

A N

IC

A L S

C H

E D

U L E

S

P .M

A R

K S

/2

/2

E

K

B

M .R

U S

S E

L L

L I

/1

/2

A M

D

R E

V

IS

E D S

C H

E D

U L E

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

C

K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

C L

K T

W R

B

C L

K T

W R

E -0

.d g n

E-001

D F

L O

O R R

E M

O D

E L

K H

E N

N E

M A

N

D M

O R

IT

Z

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

34.

35.

26.

27.

28.

29.

30.

31.

32.

33.

45.

46.

47.

48.

49.

50.

51.

52.

17.

18.

19.

20.

21.

22.

23.

24.

25.

36.

37.

38.

39.

40.

41.

42.

43.

44.

53.

54.

55.

56.

INSTALLATION OF SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS

OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY

CODE, AND OCCUPATIONAL SAFETY AND HEALTH ACT AND APPLICABLE

LOCAL CODES AND REGULATIONS AT TIME OF CONTRACT AWARD.

VERIFICATION OF DIMENSIONS IN THE FIELD SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR FOR DEVIATIONS DURING

CONSTRUCTION. EXACT LOCATION TO BE DETERMINED IN FIELD TO

AVOID INTERFERENCES WITH EXISTING UTILITIES AND PROXIMITY TO

HOT PIPES OR HOT EQUIPMENT.

ELECTRICAL LAYOUT DRAWINGS ARE PARTIALLY DIAGRAMMATIC. REFER

TO STRUCTURAL AND MECHANICAL DRAWINGS FOR GUIDANCE ON

DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES,

STRUCTURAL DETAILS, LOCATIONS OF DUCTS, PIPES AND STRUCTURAL

STEEL INSTALL ELECTRICAL SYSTEMS WITHOUT INTERFERING WITH

DUCTS, PIPES, STRUCTURAL STEEL OR OTHER SYSTEMS. RACEWAY

ROUTINGS SHALL NOT INTERFERE WITH THE PROPER AND SAFE

OPERATION OF EQUIPMENT AND SHALL NOT BLOCK OR INTERFERE WITH

INGRESS OR EGRESS, INCLUDING EQUIPMENT REMOVAL HATCHES.

ROUTE TO MAINTAIN HEADROOM AND PRESENT A NEAT APPEARANCE

TIGHT TO STRUCTURE CEILING WHEREVER POSSIBLE. GOVERNMENT

SHALL HAVE FINAL APPROVAL OF ALL EQUIPMENT AND CONDUIT

ROUTINGS PRIOR TO INSTALL.

*PROVIDE ADDITIONAL SUPPORTS FOR SWITCHES, STARTERS,

RACEWAYS, GROUNDING SYSTEM, AND OTHER ELECTRICAL EQUIPMENT

WHEREVER THE BUILDING STRUCTURE IS NOT SUITABLE FOR DIRECT

MOUNTING. PROVIDE SUPPORT AT EACH BOX, PROVIDE ADDITIONAL

SUPPORT WITHIN 3 FEET OF ACH BOX AND FITTING. USE STRAP TYPE

CONDUIT SUPPORTS FOR EXPOSED CONDUITS ON WALLS. CONDUIT

SHALL NOT BE SUPPORTED BY OTHER CONDUIT, PIPING, HVAC

DUCTWORK, OR SUSPENDED CEILING SUPPORTS.

PROVIDE INSULATING BUSHINGS AT TERMINATION OF CONDUITS AT

BACKBOXES.

EXCEPT FOR CONDUIT NIPPLES SORTER THAN 24 INCHES, DO NOT RUN

MORE THAN NINE CURRENT CARRYING CONDUCTORS IN ONE CONDUIT.

KEEP LOW VOLTAGE WIRING (30 VOLTS AND LESS), 120V WIRING AND

480V WIRING IN SEPARATE CONDUITS.

HVAC CONTROL POWER SHALL BE DERIVED FROM CONTROL

TRANSFORMERS, NOT FROM LIGHTING AND RECEPTACLE CIRCUITS.

BOXES LOCATED ON OPPOSITE SIDES OF NON-FIRE WALLS SHALL BE

OFFSET A MINIMUM OF 6”HORIZONTALLY, BOXES ON OPPOSITE SIDES OF

FIRE WALLS SHALL BE OFFSET A MINIMUM OF 24”HORIZONTALLY.

“THRU-THE-WALL” BOXES SHALL NOT BE ALLOWED WITHOUT PRIOR

WRITTEN APPROVAL BY THE CONTRACTING OFFICER.

DRAWINGS THE ARRANGEMENT AND ROUTING OF LIGHTING AND

RECEPTACLE BRANCH CIRCUITS WILL BE AT THE CONTRACTORS

DISCRETION IN ACCORDANCE WITH GENERALLY ACCEPTED GOOD

PRACTICES, NEC REQUIREMENTS AND THE FOLLOWING LIMITATIONS:

CIRCUITS. PROVIDE

FOR ALL HOME RUNS WITH MORE

ACCESSABLE

COPPER, TYPE THWN. USE SOLID FOR #10 AWG AND SMALLER AND

STRANDED FOR #8 AWG AND LARGER. MINIMUM CONDUCTOR SIZE

SHALL BE #12 AWG, AND MINIMUM CONDUIT SIZE SHALL BE 3/4 INCH

RIGID GALVANIZED STEEL OR EMT.

CONNECTING INTO EXISTING JOHNSON CONTROL SYSTEM TO BE

PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR.

ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL

CONTRACTOR BUT IT IS THE MECHANICAL CONTRACTORS

PROJECT. ALL HVAC CONTROLS TO BE INSTALLED IN METAL RACEWAY

SYSTEMS.

LOCATIONS.

NECESSARY, CONDUIT, WIRING, AND ACCESSORIES FOR ALL

ELECTRICAL EQUIPMENT.

PULLING TENSIONS AND RECOMMENDED INSTALLATION PROCEDURES.

ANY CABLE FOUND DAMAGED AND/OR FAILS TO PERFORM TO

MANUFACTURERS SPECIFICATIONS WILL BE REPLACED BY

CONTRACTOR AT NO COST TO OWNER.

BASED UPON DESIGN LOADS. PRIOR TO INSTALLATION, CONFIRM

LOADS VIA CERTIFIED SHOP DRAWINGS. IF EQUIPMENT PROVIDED IS

DIFFERENT THEN THE BASIS OF DESIGN THEN THE CONTRACTOR IS

RESPONSIBLE TO COORDINATE AND PROVIDE ELECTRICAL

CONDUCTORS WITHIN THE FOLLOWING MAXIMUM LENGTH LIMITS:

EXCEPT WHERE NOTED OTHERWISE, SIZE BRANCH CIRCUITS

(MEASURE TO THE CENTER OF THE LOAD FOR LIGHTING CIRCUITS

AND THE MOST REMOTE OUTLET FOR RECEPTACLE CIRCUITS)

THAN 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY.

ALL LIGHTING AND RECEPTACLE CIRCUITS SHALL BE 3#12 AWG, 3/4"C

UNLESS NOTED OTHERWISE ON DRAWINGS OR IF PREVIOUSLY

STATED CONDITIONS APPLY.

NEUTRAL INSTALLED WITH SWITCHED PHASE CONDUCTORS.

10.

12.

INSTALLATION OF ALL THE WORK WITHOUT INTERFERENCE.

CONTRACTOR SHALL COOPERATE WITH OTHER TRADES TO PERMIT THE

ELECTRICAL WORK IN A NEAT AND WORKMANLIKE MANNER. THE

IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO INSTALL ALL

DETAILS NECESSARY FOR THE COMPLETE ELECTRICAL INSTALLATION.

FIXTURES, EQUIPMENT, CONDUITS, WIRING, ETC., AND THE GENERAL

THE PROJECT PLANS INDICATE GENERALLY THE LOCATION OF OUTLETS,

NOT SHOWN OR ARE NOT SPECIFIED IN DETAIL.

NECESSARY TO FULLY COMPLETE THE WORK EVEN IF SAID DETAILS ARE

FURNISH AND INSTALL ALL DEVICES AND APPURTENANCES WHICH ARE

EVERY EQUIPMENT DETAIL. THE CONTRACTOR SHALL, HOWEVER,

THE SPECIFICATIONS AND DRAWINGS ARE NOT INTENDED TO COVER

OF ELECTRICAL WORK SPECIFIED AND INDICATED ON THE DRAWINGS.

THE CONTRACTOR SHALL FURNISH AND INSTALL THE VARIOUS SYSTEMS

ADJUSTMENTS, ETC.

TRANSFORMER TAP SELECTION, TIMER AND CONTROL DEVICE

OVERCURRENT AND TRIP DEVICES, LOAD BALANCING ON PANEL BUSES,

OPERATING CONDITIONS. THIS SHALL INCLUDE SETTINGS OF ALL

SPECIFICATIONS, SHALL BE ADJUSTED IN THE FIELD TO MEET

APPARATUS, WHETHER FURNISHED ON THE DRAWINGS OR

CONTRACTOR SHALL SET OPERATING LIMITS OF ELECTRICAL

POWER EQUIPMENT AND DEVICES.

COMPLETED, THE CONTRACTOR SHALL REMOVE ALL TEMPORARY

INSTALLED USING TYPE SO PORTABLE CABLE. AFTER CONSTRUCTION IS

INSTALLED. ALL CONNECTIONS SHALL BE WATERTIGHT WITH WIRING

SYSTEM. GROUND FAULT INTERRUPTING EQUIPMENT SHALL BE

WEATHERPROOF PANEL(S), FOR THE MAIN BREAKERS AND DISTRIBUTION

UTILITY COMPANY INVOLVED. THIS TEMPORARY SYSTEM SHALL INCLUDE

CONSTRUCTION IN ACCORDANCE WITH THE REQUIREMENTS OF THE

TEMPORARY POWER AND LIGHTING SYSTEMS NEEDED FOR

THE CONTRACTOR SHALL FURNISH, INSTALL AND MAINTAIN ALL

COMPATIBLE PRIMER.

SHALL BE TOUCHED UP WHERE DAMAGED OR MARKED, USING

ALL SHOP PRIMED SURFACES SHALL BE THOROUGHLY CLEANED, AND

GLIDDEN, CLEVELAND, OH SHERWIN WILLIAMS, CLEVELAND, OH

PPG INDUSTRIES (PITTSBURGH PAINT) PITTSBURGH, PA

MANUFACTURED BY ONE OF THE FOLLOWING MANUFACTURERS:

ALL PAINTING MATERIALS SHALL BE ANTI-CORROSIVE TYPE AS

GROUND WIRE IN FLEXIBLE CONDUIT SECTIONS IF REQUIRED PER CODE.

ABOVE CEILING PER THE SPECIFICATIONS. PROVIDE INDEPENDENT

FLEXIBLE METAL CONDUIT MAY ONLY BE USED TO LIGHT FIXTURES

PRODUCING EQUIPMENT FOR VIBRATION ISOLATION PURPOSES.

PROVIDE 3' LIQUIDTIGHT CONDUIT CONNECTIONS TO ALL VIBRATION

CONDUITS. DO NOT DRILL THROUGH EXISTING JOIST.

REPAINT ANY DAMAGE TO EXISTING WATERPROOFING AROUND

NON-SHRINK TO PROVIDE WATERTIGHT SEAL. CONTRACTOR SHALL

CONDUIT AND CORED HOLE SHALL BE GROUTED OR SELAED WITH

REMOVE ADDITIONAL CONCRETE AT ELBOWS ANNULAR SPACE BETWEEN

SEAL ALL NEW CORE DRILLED HOLES. CONTRACTOR SHALL CHIP AND

CORE DRILLS AS CLOSE TO WALL AS POSSIBLE. CONTRACTOR SHALL

CONCRETE SLAB OR WALL FOR CONDUIT PLACEMENT. KEEP ALL FLOOR

*CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING THROUGH

MORE CHANNELS ADJACENT.

SERIES 44 FOR CATEGORY 6A CABLES. PROVIDE GANG PLATES TO ADD

CHANNELS IF 80 PERCENT OF ANY CHANNEL HAS BEEN FILLED. USE

CABLES REQUIRED TO PASS THROUGH WALL AND ADD ADDITIONAL

MUST BE ACCOMPLISHED. SIZE SOLUTION BASED ON TOTAL NUMBER OF

THROUGH A FIRE RATED WALL OR FLOOR AND REMOVAL OF CABLES

COMMUNICATION CABLING SHALL BE USED WHERE PASSING CABLES

STI EZ-PATH SYSTEM FOR HORIZONTAL CABLE SYSTEMS FOR

SYSTEMS SPECIFICALLY LISTED FOR THE APPLICATION.

RATED WALLS FLOORS OR CEILINGS. UTILIZE UL LISTED FIRESTOP

PROVIDE FIRE STOPPING AROUND ALL RACEWAYS PENETRATING FIRE

APPROVED BY OWNER OR ENGINEER.

ONLY LARGE RADIUS BENDS WILL BE ALLOWED IN CONDUIT UNLESS

OF THE WALLS OR CEILING. NO DIAGONAL RUNS WILL BE PERMITTED.

SYMMETRICAL. CONDUITS MAY ONLY BE RUN PARALLEL TO THE PLANES

TRUE; ELBOWS, OFFSETS AND BENDS SHALL BE UNIFORM AND

WITH EQUIPMENT PROVIDED. COUNDUIT RUNS SHALL BE STRAIGHT AND

COORDINATE FLOOR PENETRATIONS AND ROUTINGS FOR CONDUITS

IN ALL SPARE DUCTS, TYPICAL, ALL CONDUITS.

INSTALL MULETAPE PRE-MEASURED, 400LB. CONDUIT MEASURING TAPE

INCH HIGH LETTERING ANDF ATTACH WITH NON-FERROUS SCREWS.

WHITE LAMINATE WITH BLACK CORE AND SHALL BE ENGRAVED WITH 3/8

VOLTAGE AND PHASE, PHASE WIRING COLORS. NAMEPLATES SHALL BE

HAVE NAMEPLATES DESIGNATING SOURCE, PANEL OR STARTER NAME,

COLORS, AVAILABLE AIC. ALL OTHER PANELS, STARTERS, ETC. SHALL

HAVE NAME, SOURCE NAME, VOLTAGE AND PHASE, PHASE WIRING

NAMEPLATES AS SHOWN IN THE CONTRACT DRAWINGS. PANELS TO

ALL EQUIPMENT AND DEVICES SHALL BE LABELED WITH THE

FOR PAINTED SURFACES APPLY TWO COATS OF ORIGINAL PAINT.

CONSTRUCTION IT SHALL BE RESTORED TO ITS ORIGINAL CONDITION

WHERE FINISH OF THE EQUIPMENT OR STRUCTURE IS DAMAGED DURING

EQUIPMENT.

SEE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF HVAC

MAY ONLY BE USED FOR LOW VOLTAGE COMMUNICATION TYPE WIRING.

CLEARLY MARKED. IN AREAS WITH A SUSPENDED CEILING CABLE TRAY

AREA SERVES AS A PLENUM THE CABLES MUST BE PLENUM RATED AND

ALL CABLES SHALL BE RUN IN CONDUIT. IF CABLE TRAY IS USED AND THE

AND BOND TO BUILDING GROUND SYSTEM AND CABLE TRAYS.

STRAPS TO THE CASE WORK OF ALL ELECTRONIC EQUIPMENT RACKS

COPPER BRAIDED BONDING STRAPS. PROVIDE BRAIDED GROUNDING

RISERS FROM NEW TGB OR SUITABLE HIGH CONDUCTIVITY TIN PLATED

COMMUNICATION EQUIPMENT SHALL BE GROUNDED WITH #6 COPPER

COMPRESSION RANGE AT BEGINNING OF PROJECT.

LISTED COMPRESSION TOOL TO BE CERTIFIED FOR PROPER

USE COMPRESSION TYPE CLAMPS ON EACH END INSTALLED WITH

GROUND BAR IN BASEMENT TO NEW TGB IN COMMUNICATION ROOM.

INSTALL A #3/0 BARE COPPER GROUND GRID RISER FROM EXISTING

RESPONSIBILITY TO PROVIDE COST PROVISIONS IN THE BIDDING OF

ELECTRICAL GENERAL NOTES ELECTRICAL GENERAL NOTES (cont) ELECTRICAL GENERAL NOTES (cont)

G E

N E

R A

L N

O T

E S

POWDER ACTUATED ANCHORS SHALL NOT BE PERMITTED.

REQUIREMENT CHANGES AT NO ADDITIONAL COST TO THE OWNER.

SIZING OF BRANCH CIRCUITS FOR MANY OF THE EQUIPMENT LOADS IS

HVAC/DDC CONTROL WIRING AND UNITARY CONTROLLERS FOR

WHERE CONDUIT AND WIRING HAS NOT BEEN SHOWN ON THE

A.

#12 #10 #8 #6

120V, 20A 65' 110' 165' 270'

B. PROVIDE #12 AWG MINIMUM FOR ALL 120 VAC

ADDITIONAL DERATING PER NEC

C.

D. LIGHTING SWITCH LOCATIONS SHALL ALL HAVE AN

WIRING FOR LIGHTING, POWER AND BRANCH CIRCUITS SHALL BE

ALL EXTERIOR ELECTRICAL ENCLOSURES SHALL BE NEMA TYPE 3R

CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL

CONTRACTOR SHALL INSTALL ALL CABLING WITHIN MANUFACTURERS

/2

/2

L .I

N G

R

M

COMMUNICATION GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

11.

13.

14.

15.

INSTALLATIONS AND ASSOCIATED EQUIPMENT OR LIGHTING.

MULTIWIRE BRANCH CIRCUITS ARE NOT ALLOWED FOR EMERGENCY

CABLE TRAYS.

COLORS AS STATED AT ALL JUNCTION BOXES OR CONNECTION TO

SPECIFICATION USE CONDUIT TYPE AS REQUIRED AND PAINT SAME

COLOR, OR EQUAL, IF EMT CONDUIT IS NOT ALLOWED PER

CIRCUITS, AND YELLOW FOR LIGHTING CONTROL. USE ALLIED TRUE

PROVIDE BLUE CONDUIT FOR DDC CIRCUITS, RED FOR FIRE ALARM

WHERE EMT CONDUIT IS ALLOWED FOR COMMUNICATION CIRCUITS

OR SOURCE.

CONTRACTOR TO PROVIDE GFI PROTECTION EITHER WITH EQUIPMENT

INTEGRAL TO VFD OR POWER CONVERSION APPLICATIONS.

GFI PROTECTION SHALL BE PROVIDED AT THE SOURCE LEVEL OR

CEILINGS. MINIMUM WIDTH OF WORK SPACE SHALL BE 30 INCHES.

THE EQUIPMENT. INCLUDES EQUIPMENT LOCATED ABOVE SUSPENDED

EQUIPMENT WHERE THE DISCONNECT MOUNTED ON OR INTEGRAL TO

WORKING SPACE OF 3.5 FEET CLEAR SHALL BE PROVIDED FOR ALL HVAC

POLARITY.

ALL BUS IN PANELS SHALL BE CLEARLY LABELED FOR PHASE AND/OR

APPROVED BY ENGINEER.

MOUNT, POP-UP, OR IN VERTICAL FACE OF CABINET. METHOD TO BE

FACE-UP. THEY MUST BE INSTALLED VERTICALLY IN TOMBSTONE STYLE

NO HORIZONTAL SURFACE MOUNTED RECEPTACLES WILL BE INSTALLED

WIRING DEVICES SHALL BE INSTALLED WITH 32 THREAD SCREWS ONLY.

MANUFACTURER WITH LISTED WEIGHT CAPACITY.

BACKBOXES TO SUPPORT EQUIPMENT SHALL BE STAMPED BY

CABLE TRAY LABELING SHALL BE INSTALLED PER NEC 230.44.

RECEPTACLES, GARAGES AND SERVICE BAYS.

SOURCE, DISHWASHERS, LAUNDRY AREAS, ROOFTOP SERVICE

GFI RECEPTACLES MUST BE USED WITHIN 6 FOOT OF ANY WATER

AS POSSIBLE BETWEEN EACH PHASE AT TIME OF CONSTRUCTION.

NEUTRAL SHALL BE LABELED 2,4,6. BALANCE PANELBOARD AS EVENLY

WITH 3 WIRES FOR 3 PHASE SERVICE CONDUCTORS LABELED 2, 4, OR 6,

AT POINT OF TERMINATION ON CONDUCTOR. EX: MULTIWIRE CIRCUIT

ENCLOSURES MUST BE LABELED WITH ASSOCIATED CIRCUIT NUMBERS

NEUTRAL CONDUCTORS TERMINATED IN PANELBOARDS OR ELECTRCIAL

CONTINUOUS WHITE OR GRAY STRIPES PER NEC.

NEUTRAL INSULATION COLOR SHALL BE WHITE, GRAY, OR THREE

NEUTRAL WITH CIRCUIT PER NEC.

CIRCUITS MUST BE GROUPED AND MARKED TO INCLUDE ASSOCIATED

CIRCUITS OCCUPY A SAME JUNCTION BOX OR ENCLOSURE, ALL

WHERE MORE THAN ONE NEUTRAL ASSOCIATED WITH MULTIPLE

REQUIREMENTS OF LOCKABLE DISCONNECTING MEANS PER NEC 110.25.

ALL DISCONNECTING MEANS SHALL BE PROVIDED TO MEET THE

ASSOCIATED SECTIONS.

PROVIDED PER ALL SECTIONS OF NEC 110.21 AND 110.24 AND

PROPER MARKINGS FOR ALL ELECTRICAL EQUIPMENT SHALL BE

GROUNDING AND BONDING CONNECTIONS.

ANY OTHER ELECTRICAL SOURCE OTHER THAN THOSE ESTABLISHED BY

THERE SHALL BE NO DIRECT CONNECTION TO CIRCUIT CONDUCTORS OF

AND LIGHTING SHALL BE IN EMT INTERIOR TO BUILDING.

APPROVED BY OWNER OR ENGINEER. BRANCH WIRING TO RECEPTACLES

INTERIOR FEEDER CONDUITS SHALL BE IN RGS CONDUIT UNLESS

RACEWAY PER THE MANUFACTURER AND CODE.

CONSTRUCTION OR DUE TO THERMAL CHARACTERISTICS OF THE

SYSTEMS WHERE REQUIRED BASED ON EXPANSION JOINTS IN BUILDING

CONTRACTOR TO PROVIDE EXPANSION COUPLINGS IN ALL RACEWAY

THE THREADS.

PAINT SHALL BE APPLIED IMMEDIATELY AFTER CUTTING AND CLEANING

THREADS SHALL BE RE-GALVANIZED USING A ZINC-RICH PAINT, SUCH

AFTER THE THREADS ARE CUT TO REMOVE BURRS. NEWLY CUT

CONDUITS THAT REQUIRE THREADING MUST BE THOROUGHLY REAMED

WITHOUT ADDITIONAL COMPENSATION.

NECESSARY TO MEET THE EQUIPMENT REQUIREMENTS SHALL BE MADE

THE CONTRACTOR AND ANY MODIFICATION OF THE ELECTRICAL WORK

CONTRACTOR PRIOR TO THIS REVIEW WILL BE THE RESPONSIBILITY OF

DISCREPENCIES BFORE ANY SUCH WORK INSTALLED BY THE

ALSO VERIFY LOCATIONS PRIOR TO INSTALL AND REPORT AND

ENGINEER, AND RETURNED TO THE CONTRACTOR. CONTRACTOR SHALL

SHOP DRAWINGS FOR SUCH WORK ARE COMPLETED, REVIEWED BY THE

THE CONTRACTOR SHALL NOT PERFORM ANY ELECTRICAL WORK UNTIL

SUCH CHANGES WITHOUT ADDITIONAL COST TO THE OWNER.

CHANGES AND, UPON REVIEW PROCEED WITH THE INSTALLATION OF

THE ENGINEER/OWNERS REPRESENTATIVE FOR REVIEW THE PROPOSED

OTHER WORK BEING INSTALLED, THE CONTRACTOR SHALL SUBMIT TO

IF CHANGES BECOME NECESSARY TO AVOID INTERFERENCE WITH

E L E

C T

R

IC

A L C

O M

M U

N

IC

A T

IO

N

W E

K

B

REQUIRED TO MAINTAIN DOCUMENTATION OF THIS FOR EACH SITE.

DROP EXISTS AND ITS CABLE LABEL. VERIFY WITH THE BASE IT OFFICE IS

FINAL AS-BUILT LOCATION AND ROUTING OF WHERE EACH DATA CABLE

CONTRACTOR TO PROVIDE DRAWINGS ACCURATELY RECORDING THE

CONSTRUCTION CONTRACT REQUIRES THE CONSTRUCTION

STILL IN PLACE.

BASE-IT AT TIME OF CONSTRUCTION TO VERIFY SAME SCHEMES ARE

TO DIGITAL, OR IF NEEDED TO MOVE A FAX MACHINE. COORDINATE WITH

ANALOG LINES. THIS WAS DONE TO ACCOMMODATE FUTURE TRANSITION

RUNS TO THE MAIN COMPUTER DISTRICT SERVER ROOM FOR THE

RATHER THAN PLUG INTO THE SWITCH THEY PATCH TO A PANEL THAT

RESERVED A SWITCH AND PORT NUMBER AND LABELED AS SUCH, BUT

OR WI-FI OR OTHER NETWORK DEVICES. CONSIDER THAT FAX LINES ARE

NOTE THAT THE FIRST 20 PORTS ON SWITCH A ARE TYPICALLY PRINTERS

AND SWITCH D LOCATED ON THE TOP OF THE RACK RESPECTIVELY.

SWITCH A THRU SWITCH D WITH SWITCH A LOCATED ON THE BOTTOM

NOTE THAT THE SWITCHES ARE LABELED (OR SHOULD BE LABELED) AS

AND ADD PATCH PANEL IF REQUIRED TO MATCH EXISTING.

RACKS AND A RACK EXISTS FOR EACH FLOOR. REUSE PATCH PANELS

THERE ARE MULTIPLE SWITCHES AND PATCH PANELS IN EXISTING

THE SWITCH LABELED A AND 42 IS THE PORT NUMBER ON THAT SWITCH.

EXAMPLE LABEL: “2-A42” WHERE (LEFT TO RIGHT) 2 IS THE FLOOR, A IS

DATA NETWORK CABLING TO HAVE THE FOLLOWING LABEL SCHEME:

CABLING.

THAT IS AND FOR EXISTING ACCESS POINT MODEL. RECONNECT STATION

CEILING IS IN PLACE, PROVIDE LOCKAQBLE 2 X 2 ACCESS POINT MOUNT

STATION CABLING UNTIL RENOVATION IS COMPLETED. ONCE NEW

ROOF STRUCTURE BAG ACCESS POINT AND DISCONNECT EXISTING

ACCESS POINT AND MOVE TO ABOVE CEILING TO ROOF STRUCTURE. AT

TO BE VERIFIED IN FIELD. CONTRACTOR SHALL REMOVE EXISTING

THE EXISTING WI-FI TO BE RELOCATED, ALLOW FOR 2 LOCATIONS IN BID

CONTRACTOR:

ACE-IT. THE FOLLOWING IT REQUIREMENTS MUST BE PROVIDED BY

COORDINATE NUMBER AND LOCATIONS OF WI-FI ACCESS POINTS WITH

SWITCH AS REQUIRED.

NEW CEILING AND PROVIDE NEW DATA CONNECTION BACK TO NEAREST

MAINTAIN AND PROTECT THE EXISTING WIRELESS ACCESS POINTS IN

DATA CABLE SPLICES ARE NOT ALLOWED.

RESPECTIVE SWITCHES LOCATED IN THE EXISTING SWITCH ROOM.

DESIGN SHALL ALLOW FOR NEW DATA CABLES ROUTED TO EXISTING

RESPECTIVE SWITCH LOCATED IN THE EXISTING SWITCH ROOM.

DATA CABLE SHALL BE CATEGORY 6 ROUTED BACK TO THE NEAREST

PRINTERS, COPIERS, AND PLOTTERS, ETC.

THAT EXIST ON THE SECOND FLOOR ANNEX: THE CONFERENCE ROOM,

PROVIDE ONE CATEGORY 6 DATA DROP FOR EACH OF THE FOLLOWING

PROVIDE ONE CATEGORY 6 DATA DROP PER CUBICAL.

IT REQUIREMENTS.

CABLE LABELING REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE

ENGINEER.

CONTRACTING OFFICER’S REPRESENTATIVE AND THE PROJECT

ISLAND DISTRICT (CEMVR) IT CHIEF DURING DESIGN THROUGH THE

CABLING FOR EACH SPACE SHALL BE COORDINATED WITH THE ROCK

SALVAGING, MAINTAINING, PROTECTING, NEW LAYOUT, AND NEW

INFORMATION TECHNOLOGIES (IT) DISCONNECTION, REMOVAL,

TO THE ACEIT DATA NETWORK AND WILL BE AN INDEPENDENT SYSTEM.

CONTROL. THE LIGHTING CONTROL CABLING SHALL NOT BE CONNECTED

NLIGHT LIGHTING CONTROL SYSTEM IS BASIS OF DESIGN FOR LIGHT

L I

/1

/2

A D

M

R E

V

IS

E D N

O T

E

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

E-003

O

C K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

E X

D M

O R

IT

Z

B

C L

K T

W R

E -0

.d g n

B

C L

K T

W R

K H

E N

N E

M A

N

N

D F

L O

O R R

E M

O D

E L

1.

2.

3.

4.

5.

6.

1.

2.

3.

COMMUNICATION INSTALLATION NOTES:

7.

8.

9.

WILL BE PROVIDED BY INSTALLER.

DOCUMENTED ON A MAP THAT WILL BE PROVIDED AFTER INSTALLATION

THE CABLE RUN ROUTES AND WORK AREA DROP NUMBERS WILL BE

POSSIBLE.

CABLE RUNS WILL BE KEPT NEAT AND IN STRAIGHTEST BUNDLES

THE WIRING SCHEME WILL BE TIA-568B.

PARTS AND IN TESTING OF THE FINAL PRODUCT.

THE INSTALLATION OF ALL CABLING, HARDWARE, AND MISCELLANEOUS

BEST PRACTICES AND TIA/EIA-568 STANDARDS WILL BE FOLLOWED WITH

EIA/TIA.

TO MEET THE CABLES INSTALLED PERFORMANCE STANDARDS PER

CABLE, AND PORT PANEL CONNECTION WITH CERTIFIED TEST RESULTS

BE A CABLING SYSTEMS WARRANTY INCLUDING THE STATION OUTLET,

WARRANTIES FOR THIS PROJECT DIRECTLY TO THE OWNER. THIS SHALL

THE CONTRACTOR SHALL BE ABLE TO EXTEND THE MANUFACTURER'S

REFERENCE.

COMPONENTS INSTALLED WITH WRITTEN REFERENCES FROM ACTUAL

COMPLETED AT LEAST THREE (3) SIMILAR SIZE PROJECTS WITH SAME

THE CONTRACTOR FOR THIS WORK SHALL HAVE SUCCESSFULLY

TO INSTALLATION FOR REVIEW.

CERTIFICATES SHALL BE SUBMITTED AND REVIEWED BY OWNER PRIOR

CERTIFICATES SHALL BE CURRENT FOR PERIOD OF WORK.

TO BE SCANNED BY OWNER AND RETURNED TO INSTALLER.

MANUFACTURER AND PROVIDE MANUFACTURER’S ACTUAL CERTIFICATE

SHALL HAVE FACTORY CERTIFICATION FROM EACH COMPONENT

4.) PROVIDE CERTIFICATIONS THAT ALL INSTALLERS OF THIS SYSTEM

PROVIDED BEFORE PROCEEDING WITH THE INSTALLATION.

MUST BE PROVIDED FOR EACH TYPE OF SYSTEM ABOVE. THIS SHALL BE

3.) IF THIS INSTALLATION IS COPPER SYSTEMS THEN 3 REFERENCES

COMMUNICATION PROJECTS.

TELEPHONE NUMBERS REGARDING SUCCESSFUL COMPLETION OF DATA

PROVIDE THREE (3) REFERENCES WITH CONTACT NAMES AND

VOLTAGE DATA COMMUNICATION TRADE FOR THREE YEARS AND

2.) THE CONTRACTOR MUST SHOW CERTIFICATION OF BEING IN THE LOW

SUPERINTENDENT.

COORDINATE THE INSTALLATION WITH THE OWNER'S PROJECT

COMMUNICATIONS DISTRIBUTION DESIGNER) ON SITE TO OVERSEE AND

1.) CONTRACTOR SHALL HAVE A REGISTERED R.C.D.D. (REGISTERED

CONSTRUCTION ENGINEER PRIOR TO SYSTEMS INSTALLATION:

B.THE CONTRACTOR MUST PROVIDE COPIES OF THE FOLLOWING TO THE

(LV-U) CLASS CERTIFICATION.

VOLTAGE TELECOMMUNICATIONS (LV-T) OR LOW VOLTAGE UNLIMITED

A.THE CONTRACTOR IN THE STATE OF INSTALLATION MUST HAVE A LOW

VOICE AND DATA SYSTEMS INSTALLER'S QUALIFICATIONS:

COUNT: ==6-pair)

CABLE DIAMETER X 4 FOR HORIZONTAL CABLE W/O SHIELD (PAIR.

A. PREMISES COPPER-CONDUCTOR CABLE

REQUIREMENTS)

RECOMMENDED MINIMUM BENDING RADIUS (OR MANUFACTURERS

COMMUNICATION CABLES:

USE THE FOLLOWING GUIDELINES FOR INSTALLATION OF

4.

5.

6.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

P O

W E

R A

N D C

O M

M U

N

IC

A T

IO

N N

O T

S

L E

C T

R

IC

POWER / COMMUNICATION NOTES:

/2

/2

L .I

N G

R

(cont):

COMMUNICATION INSTALLATION NOTES

CERTIFIED BY MANUFACTURER APPROVED INSTALLER.

OUTLETS SHALL BE A WARRANTIED SYSTEMS AND INSTALLED AND

HORIZONTAL STATION CABLING, WALL PLATES AND WORKSTATION

HIGH DENSITY 48 PORT. THE PATCH PANELS, TERMINATION OUTLETS,

PATCH PANELS IN THE CABINET WITH NEW PATCH PANELS THAT ARE

ALONG WITH ASSOCIATED PATCH PANELS. REPLACE THE EXISTING

CATEGORY CABLE CURRENTLY ON SECOND FLOOR SHALL BE REMOVED

SECOND CABINET SERVICES THE SECOND FLOOR. ALL OF THE EXISTING

CABINET CLOSEST TO THE WALL SERVICES THE FIRST FLOOR. THE

IN COMMUNICATION ROOM THERE ARE 2 EXISTING CABINETS. THE

568B. BUT VERIFY WITH GOVT. PRIOR TO STARTING PROJECT.

WORKSTATION CATEGORY 6 UTP CABLE TERMINATIONS SHALL BE EIA

STRUCTURE FROM CABLE TRAY TO CONDUIT DROPS.

ON CENTER SUPPORT SPACING ATTACHED TO BOTTOM OF 2ND FLOOR

PERFORMANCE OF CABLES. ERICO CADDY CAT OR EQUAL AND 4 FEET

LOCATIONS, PROPERLY SUPPORT STATION CABLING TO NOT DEGRADE

ROUTED ABOVE 1ST FLOOR CEILING TO THE INTERIOR FLOOR ACCESS

AND BACK INTO FLOOR OPENING AT LOCATION SHOWN. WHERE CABLE IS

DUCT BY ROUTING UNDERFLOOR THROUGH EXISTING CONDUIT SLEEVE

EXTERIOR WALL SERVICE POINTS AT COLUMNS, OR IN CELLULAR FLOOR

AND BE ROUTED IN EITHER COMMUNICATION CABLE TRAY FOR

HORIZONTAL WORKSTATION CABLING SHALL BE CATEGORY 6 UTP CABLE

EACH WORKSTATION WILL HAVE A DUPLEX COMMUNICATION OUTLET.

DIFFERENT CIRCUIT.

DIRECTION. EACH RECEPTACLE IN A WORKSTATION WILL BE ON A

120V CIRCUITS ARE PROVIDED FOR EACH 8 WORKSTATIONS PER GOVT.

EACH WORKSTATION SHALL HAVE 2 DUPLEX 120V RECEPTACLES. TWO

CABLE. VIDEO CABLE BY GOVERNMENT.

THAT IS SHOWN ADJACENT AND EXTRA CONDUIT FOR VIDEO MEDIA

MONITOR SIZE TO BE USED. EACH FSR BOX WILL HAVE 120V CIRCUIT

SHALL BE AN FSR WBX BOX AND LOCATED PER GOVT. DIRECTION FOR

PROVIDE SERVICE TO 2 MONITORS PER CONFERENCE ROOM. A/V BOX

CONFERENCE ROOMS WILL HAVE A/V BOXES LOCATED PER DETAILS TO

CABLES.

ACCESS TO PROPER CHANNEL FOR ELECTRICAL AND COMMUNICATION

PROPER OPENINGS IN CONCRETE TOPPING SLAB IF REQUIRED TO GAIN

WILL NEED TO COORDINATE WITH FLOOR SYSTEM CHANNELS TO MAKE

CELLULAR FLOOR SYSTEM PER THE EXISTING DETAILS. CONTRACTOR

THE INTERIOR AREA OF EACH FLOOR WILL BE SERVICED FROM THE

FOR REQUIREMENTS. THE WORKSTATIONS THAT ARE TO BE LOCATED IN

ALONG THE EXTERIOR WALL BY COLUMN LOCATIONS. SEE DETAIL SHEET

SHARED GROUND. THE WORKSTATION SERVICE POINTS ARE SHOWN

ELECTRICAL TO HAVE 2 CIRCUITS WITH DEDICATED NEUTRALS AND

THE WORKSTATION FURNITURE PANELS WILL BE PRE-WIRED FOR

W E

K

B

SELECTED BY OWNER.

ELECTRONIC RECORD OF ALL DRAWINGS IN A SOFTWARE AND FORMAT

CONVENTION OF TIA/EIA-606 AS SHOWN ON DRAWING DEATILS. FURNISH

AND PATHWAYS, AND EQUIPMENT GROUNDING CONDUCTORS. FOLLOW

AREAS AND WORKSTATION TERMINAL POSITIONS, GROUNDING BUSES

TERMINAL HARDWARE AND POSITIONS, HORIZONTAL CABLES, WORK

COMMUNICATION ROOMS, BACKBONE PATHWAYS AND CABLES,

IDENTIFY LABELING CONVENTION AND SHOW LABELS FOR

LABELING IN THE AS-BUILT CABLE ADMINISTRATION DRAWINGS.

SHOW BUILDING FLOOR PLANS WITH CABLE ADMINISTRATION POINT

BY OWNER.

SCHEDULES FOR THE PROJECT IN SOFTWARE AND FORMAT SELECTED

IT AND PROVIDE AN ELECTRONIC COPY OF THE FINAL COMPREHENSIVE

DESIGNATIONS, ORIGINS, AND DESTINATIONS. COORDINATE WITH GOVT.

CABLE SCHEDULE. LIST INCOMING AND OUTGOING CABLES AND THEIR

POST IN PROMINENT LOCATION IN EACH COMMUNICATION ROOM A

USE SPLICE AND TAP CONNECTORS COMPATIBLE WITH MEDIA TYPES.

NO SPLICES ALLOWED.

ELECTRICAL POWER LINES AND EQUIPMENT.

COMMUNICATIONS CABLING FROM EMI SOURCES INCLUDING

COMPLY WITH TIA/EIA-569-A RULES FOR SEPARATING COPPER DATA

THAN MINIMUMS RECOMMENDED BY MANUFACTURER.

CONNECTIONS, AND TO PREVENT BENDING CABLES TO SMALLER RADII

USE LACING BARS TO RESTRAIN CABLES, TO PREVENT STRAINING

LENGTH. TRAIN CONDUCTORS TO TERMINAL POINTS WITH NO EXCESS.

WIRING WITHIN COMMUNICATION ROOM SHOULD PROVIDE ADEQUATE

OUTLETS, RACKS, FRAMES AND TERMINALS.

INCHES AND MORE THAN 6 INCHES FROM CABINETS, BOXES, FITTINGS,

SECURE AND SUPPORT CABLES AT INTERVALS NOT EXCEEDING 48

SURFACE CONTOURS WHERE POSSIBLE.

SURFACES OR EXPOSED STRUCTURAL MEMBERS AND FOLLOW

INSTALL CABLES IN RACEWAYS PARALLEL AND PERPENDICULAR TO

OR RACEWAY.

BASKET-WEAVE WIRE OR CABLE GRIPS, THAT WILL NOT DAMAGE MEDIA

USE PULLING MEANS, INCLUDING FISH TAPE, CABLE, ROPE AND

MANUFACTURER.

SURROUNDING MATERIALS AND HAVE BEEN APPROVED BY CABLE

COMPOUNDS THAT WILL NOT DAMAGE CONDUCTOR, INSULATION OR

USE PULLING COMPOUND OR LUBRICANT IF NECESSARY. USE

IN THE SAME RACEWAY.

PULL CABLES SIMULTANEOUSLY IF MORE THAN ONE IS BEING INSTALLED

RECOMMENDED PULLING TENSIONS.

PULL CABLES WITHOUT EXCEEDING CABLE MANUFACTURER’S

TABLE IN NOTES.

THAN MINIMUMS RECOMMENDED BY MANUFACTURER AND AS SHOWN IN

DO NOT BEND CABLES, IN HANDLING OR INSTALLING, TO SMALLER RADII

JACKET

INSTALL CABLES WITHOUT DAMAGING CONDUCTORS, SHIELD, OR

SIGNAL PATHS END-TO-END.

THAT ENSURE CATEGORY 6 PERFORMANCE OF COMPLETED AND LINKED

ARE CONSISTENT WITH CATEGORY 6 RATING OF COMPONENTS AND

INSTALL CABLES USING TECHNIQUES, PRACTICES AND METHODS THAT

EXCEPT IN UNFINISHED SPACES.

USE UL-LISTED PLENUM CABLE. CONCEAL RACEWAY AND CABLES

WHERE WIRING METHODS AS SHOWN ON DOCUMENTS MAY BE USED.

ACCESSIBLE CEILING SPACES AND IN GYPSUM BOARD PARTITIONS

CONSOLES, CABINETS, DESKS AND COUNTERS AND EXCEPT IN

INSTALL WIRING IN RACEWAY AND CABLE TRAY EXCEPT WITHIN

INSTALLATION.

DAMAGE TO THE CEILING OR FLOOR PANELS DURING CABLE

COMPONENTS. THE INSTALLER IS RESPONSIBLE FOR REPAIR OF ANY

INSTRUCTION IN THE REMOVAL AND PROTECTION OF THESE BUILDING

REVIEW CEILING AND FLOOR PANELS AND COMPLETE PROPER

UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.

INSTALLATION. PROCEED WITH INSTALLATION ONLY AFTER

HAZARDS TO CABLE INSTALLATION AND OTHER CONDITIONS AFFECTING

COMPLIANCE WITH SPACE ALLOCATIONS, INSTALLATION TOLERANCES,

CHECK RACEWAYS, CABLE TRAYS AND OTHER ELEMENTS FOR

EXAMINE PATHWAY ELEMENTS INTENDED FOR CABLES.

THE CABINET AND HARDWARE WILL BE PROPERLY GROUNDED.

NOT USED

NOT USED

DO NOT OVER TIGHTEN NYLON TIE WRAPS.

PATCH PANEL PER THE DRAWING DETAILS.

SEQUENTIAL POSITION OF THE CORRESPONDING OUTLETS IN THE

THE WALL OUTLETS WILL BE NUMBERED ACCORDING TO THE

L I

/1

/2

A D

M R

E V

IS

E D N

O T

E S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

2 3 4 5 6 7 8 9

A

B

D

A1

R O

C K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

E X

N

D F

L O

O R R

E M

O D

E L

E-101

B

C L

K T

W R

E -1

.d g n

B

C L

K T

W R

K H

E N

N E

M

2ND FLOOR ELECTRICAL POWER AND COMMUNICATIONS PLAN

N

D F

L O

O R E

L E

C T

R

IC

A L

P O

W E

R A

N D C

O M

M U

N

IC

A T

IO

N S P

L A

N

D M

O R

IT

Z

1. FOR ELECTRICAL GENERAL NOTES SEE SHEET E-001.

2. FOR ELECTRICAL LEGEND SEE SHEET E-002.

3.

INSTALLATION NOTES SEE SHEET E-003.

FOR ELECTRICAL POWER NOTES AND COMMUNICATIONS

N

4. FOR WIRING DEVICE SCHEDULE AND NOTES SEE SHEET E-603.

M A

T C

H L

IN

E F

O R C

O N

T

IN

U A

T

IO

N S

E E S

H E

E T E -1

CIRCUITS 2A-9, 11

COLUMN/ROW 2A

CIRCUITS 2A-10, 12

COLUMN/ROW 4A

CIRCUITS 2A-17, 19

COLUMN/ROW 6A

PANEL 2A & 2AS

2A-18

2A-20

CIRCUITS 2A-25, 27

COLUMN/ROW 1B

CIRCUITS 2AS-1, 3

COLUMN/ROW 1C

CIRCUITS 2AS-5, 7

COLUMN/ROW 2D

CIRCUITS 2AS-10, 12

COLUMN/ROW 4D

2AS-14, 16

FUTURE CIRCUITS

COLUMN/ROW 5D

2AS-9, 11

FUTURE CIRCUITS

COLUMN/ROW 3D

2AS-17, 19

FUTURE CIRCUITS

COLUMN/ROW 7D

CIRCUITS 2AS-13, 15

COLUMN/ROW 6D

CIRCUITS 2A-26, 28

IN FLOOR BOXES

COLUMN/ROW 3B

CIRCUITS 2AS-2, 4

IN FLOOR BOXES

COLUMN/ROW 3C

CIRCUITS 2A-30, 32

IN FLOOR BOXES

COLUMN/ROW 6B

CIRCUITS 2AS-9, 11

IN FLOOR BOXES

COLUMN/ROW 6C

RACKS TO REMAIN

COMMUNICATION

PDP-18 FOR

FROM PANEL

RECEPTACLES

EXISTING

TRENCH IN FLOOR

EXST 1'-0" WIDE

TRENCH IN FLOOR

EXST 2'-0" WIDE

TRENCH IN FLOOR

EXST 2'-0" WIDE

2A-13, 15

FUTURE CIRCUITS

COLUMN/ROW 3A 2A-14, 16

FUTURE CIRCUITS

COLUMN/ROW 5A

2A-21, 23

FUTURE CIRCUITS

COLUMN/ROW 7A

5.

SEE SHEET T-503

TELEPHONE OUTLET;

PROVIDE WALL

REQUIRED FOR STATION CABLING

48 PORT PATCH PANELS AS

CABINETS, PROVIDE NEW

EXST COMMUNICATION

SHEET T-502

SEE DETAIL ON

A/V BOXES (TYP);

R K

2AS-22 2AS-24 2AS-25

2AS-23

2AS-21

TYPE "B"

SCALE : 3/16"=1'-0"

GENERAL SHEET NOTES:

TYPE "B"

TYPE "B"

TYPE "B"

TYPE "A"

TYPE "B"

TYPE "A"

ROOF; ROUTE WITH COOLANT PIPES

CONDENSING UNIT ON THE

ACCU-217-R-1 OUTDOOR

AC-217-2-1 INDOOR UNIT UP TO

12VDC CABLES BETWEEN

FOR 208V, 120V AND

ROUTE 3-1" CONDUITS

2A-36

ABOVE CEILING

BY MECHANICAL CONTRACTOR

DDC/BMS POWER SUPPLY

2A-34

ABOVE CEILING

BY MECHANICAL CONTRACTOR

DDC/BMS POWER SUPPLY

IN-FLOOR BOX CIRCUIT 2AS-22

TO REMAIN

EXIST PANELBOARD PDP-18

(TYP FOR ALL FLOOR BOX LOCATIONS)

ARE LINED UP WITH FURNITURE PANELS.

ARRANGEMENT SO SERVICE POINTS

LOCATION WITH FINAL FURNITURE

COORDINATE EXACT FLOOR CHANNEL

6.

TO BOT 597-7"

TURN TRAY UP

TO BOT 597-7"

TURN TRAY UP FOR CATEGORY 6 CABLING

CABLE TRAY; BOT 594'-7" ABOVE CEILING,

NEW 1'-0" X 6" WIRE BASKET

FOR CATEGORY 6 CABLING

ABOVE CEILING,

CABLE TRAY; BOT 594'-7"

NEW 1'-0" X 6" WIRE BASKET

TO BOT 597'-7"

TURN TRAY UP

FOR CATEGORY 6 CABLING

CABLE TRAY; BOT 597'-7" ABOVE DUCTWORK,

NEW 1'-0" X 6" WIRE BASKET

TRAY

TO BRIDGE ACROSS BETWEEN

PROVIDE FLAT METAL PLATE

INSTALL TRAY BETWEEN TRUSS

/2

/2

L .I

N G

R

IN FLOOR BOX LOCATIONS)

(TYP FOR ALL WALL AND

SEE NOTE 5

TELECOM OUTLETS

FOR CATEGORY 6 CABLING TO WALL

CABLE TRAY; BOT 594'-7" ABOVE CEILING,

NEW 1'-0" X 6" WIRE BASKET

USE FLOOR CELLULAR DUCT OR ERICO SYSTEM

BOXES USE NOTE 4 ON DWG E-103 TO EITHER

REUSE AS NEEDED, 2ND FLOOR IN FLOOR

CABLING TO 1ST & 2ND FLOOR WORKSTATIONS;

EXST 2-5" STEEL SLEEVES IN FLOOR FOR STATION

SEE DWG M-103

CONDENSATE PUMP

AC-217.2.1 IN DOOR UNIT

E-001.

POWER REQUIREMENTS. SEE COMMUNICATION NOTES ON DWG

CIRCUITS SHOWN FOR 120V SERVICE TO WORK STATION 120V

TO MAINTAIN A FINISHED CEILING HEIGHT OF 8'-0". ALSO PROVIDE

REMAIN. COORDINATE ALL NEW UTILITIES WITH EXISTING

DENSE WITH EXISTING DUCTWORK AND UTILITIES TO

SOME AREAS ABOVE THE FINISHED CEILING ARE VERY

W E

K

B

CONNECT TO CCURE ACS SYSTEM PER GOVT

CONNECTION OF READER & CONTROLLER TO INTERFACE

COORDINATE REQUIREMENTS WITH OWNER FOR

STRIKE & CONTROLLER AS DIRECTED BY OWNER.

PROVIDE A NEW CARD READER & DOOR ELECTRIC

CIRCUITS 2AS-23

IN FLOOR BOXES

MAINTENANCE LOOPS.

PATCH PANEL IN COMMUNICATIONS ROOM. CABLE LENGTH TO INCLUDE

TO REACH STATION OUTLETS IN WORK- STATIONS AND TO ASSOCIATED

A MINIMUM OF 2 - CATEGORY 6 CABLE. PROVIDE CABLES OF A LENGTH

OUTLET. WHERE SHOWN AS DATA OUTLET ON WALL POPULATE WITH

ALL WORKSTATIONS AND PRINTERS SHALL HAVE 1 - CATEGORY 6 UTP

WITH INTERIORS PLANS FOR WORKSTATION AND PRINTER LOCATIONS.

TO ACCOMADATE ALL WORKSTATIONS AND PRINTERS. COORDINATE

BOXES SHALL BE POPULATED WITH NEW CATEGORY 6 UTP CABLES

ALL WORKSTATION SERVICE ENTRANCE DROP COMMUNICATION

L I

/1

/2

A D

M

R E

V

IS

E D N

O T

E S A

D D

E D O

U T

L E

T S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

CE

CE A/V

CE

CECE

CE CECECECE

CE CE CE CE CE CE

C E

C E

A /V

A/VA/V

A /V

A /V

A /V

B

D

11 12 13 14 15 16 17

A1

SCALE : 3/32"=1'-0"

E-102

P O

W E

R A

N D C

O M

M U

N

IC

A T

IO

N S P

L A

N

R O

C K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

E X

D M

O R

IT

Z

B

C L

K T

W R

E -1

.d g n

B

C L

K T

W R

K H

E N

N E

M A

N

N

D F

L O

O R E

L E

C T

R

IC

A L

N

D F

L O

O R R

E M

O D

E L

2ND FLOOR ELECTRICAL POWER AND COMMUNICATIONS PLAN

N

1. FOR ELECTRICAL GENERAL NOTES SEE SHEET E-001.

2. FOR ELECTRICAL LEGEND SEE SHEET E-002.

3.

INSTALLATION NOTES SEE SHEET E-003.

FOR ELECTRICAL POWER NOTES AND COMMUNICATIONS

PANEL 2B & 2BSCIRCUITS 2B-10, 12

COLUMN/ROW 13A

TRENCH IN FLOOR

EXST 1'-0" WIDE

CIRCUITS 2B-26, 28

IN FLOOR BOXES

COLUMN/ROW 12B

M A

T C

H L

IN

E F

O R C

O N

T

IN

U A

T

IO

N S

E E S

H E

E T E -1

FOR WIRING DEVICE SCHEDULE AND NOTES SEE SHEET E-603.4.

2BS-13, 15

FUTURE CIRCUITS

COLUMN/ROW 16D

2BS-9, 11

COLUMN/ROW 15D

CIRCUITS 2B-25, 27

COLUMN/ROW 17B

2B1

CONF RM

2B2

CONF RM

CIRCUITS 2BS-17, 19

COLUMN/ROW 17C

2B-14, 16

FUTURE CIRCUITS

COLUMN/ROW 14A

CIRCUITS 2B-9, 11

COLUMN/ROW 11A

2B-13, 15

FUTURE CIRCUITS

COLUMN/ROW 12A

CIRCUITS 2B-17, 19

COLUMN/ROW 15A

2B-21, 23

FUTURE CIRCUITS

COLUMN/ROW 16A

2BS-6, 8

FUTURE CIRCUITS

COLUMN/ROW 14D

2BS-2, 4

COLUMN/ROW 13D

2BS-5, 7

FUTURE CIRCUITS

COLUMN/ROW 12D

2BS-1, 3

COLUMN/ROW 11D

2B3

CONF RM

2BS-14

2B-20

2B-18

CIRCUITS 2BS-18, 20

IN FLOOR BOXES

COLUMN/ROW 12C

CIRCUITS 2B-30, 32

IN FLOOR BOXES

COLUMN/ROW 14B

CIRCUITS 2BS-22, 24

IN FLOOR BOXES

COLUMN/ROW 14C

SHEET T-502

SEE DETAIL ON

A/V BOXES (TYP);

IN FLOOR

WIDE TRENCH

EXST 2'-0"

TYPE "A"

TYPE "A"

TYPE "B"

GENERAL SHEET NOTES:

TYPE "B"

SHEET T-502

SEE DETAIL ON

CENTERED ON WALL

TYPE "A"

TYPE "B"

TYPE "A"

TYPE "A"

CE CE

CIRCUITS 2BS-25, 27

IN FLOOR BOXES

COLUMN/ROW 14B

CIRCUITS 2BS-29

IN FLOOR BOXES

COLUMN/ROW 14B

2BS-28

2BS-26

ABOVE CEILING

BY MECHANICAL CONTRACTOR

DDC/BMS POWER SUPPLY

ABOVE CEILING

BY MECHANICAL CONTRACTOR

DDC/BMS POWER SUPPLY

TO MAINTAIN A FINISHED CEILING HEIGHT OF 8'-0".

REMAIN. COORDINATE ALL NEW UTILITIES WITH EXISTING

DENSE WITH EXISTING DUCTWORK AND UTILITIES TO

SOME AREAS ABOVE THE FINISHED CEILING ARE VERY5.

TO BOT 597'-7"

TURN TRAY UP

FOR CATEGORY 6 CABLING

CABLE TRAY; BOT 594'-7" ABOVE CEILING,

NEW 1'-0" X 6" WIRE BASKET

FOR CATEGORY 6 CABLING

CABLE TRAY; BOT 594'-7" ABOVE CEILING,

NEW 1'-0" X 6" WIRE BASKET

FOR CATEGORY 6 CABLING

CABLE TRAY; BOT 594'-7" ABOVE CEILING,

NEW 1'-0" X 6" WIRE BASKET

FOR CATEGORY 6 CABLING

ABOVE DUCTWORK,

CABLE TRAY; BOT 597'-7"

NEW 1'-0" X 6" WIRE BASKET

FROM BOT 597'-7"

DROP TRAY DOWN

/2

/2

.I

N G

R A

M

BOX LOCATIONS)

WALL AND IN FLOOR

E-101 (TYP FOR ALL

SEE NOTE 5 ON DWG

W E

K

B

L I

/1

/2

A D

M

A D

D E

D D

A T

A O

U T

L E

T S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

/V

A /V

A /V

A /V

A /V

A /V

A /V

A /V

CE CE

CECE

CE CE CE CE CE CE

C E

ECECECE E

C E

C

K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

C L

K T

W R

B

C L

K T

W R

T -5

.d g

T-502

D F

L O

O R R

E M

O D

E L

K H

E N

N E

M

D

O R

IT

Z

CSR-J1

4 5 6 7

TO PATCH PANEL

FRONT VIEW SIDE VIEW

B

A

CEI

LI

NG

SUPPORT

CABLE TRAY

C1 SCALE : NTS

C O

M M

U N

IC

A T

IO

N S D

E T

A

IL

ALL

CABLE TRAY (TYP)

BE INDEPENDENT OF

CONDUIT SUPPORT SHALL

CATEGORY CABLE (TYP)

BE LESS THAN REQUIRED FOR

CONDUIT BEND RADIUS SHALL NOT

BUSHING (TYP)

PLASTIC

2-2" EMT RECESSED IN WALL

NOTE 1

WORKSTATION CABLE TO ATTACH

BLANK FACEPLATE FOR 120V

RECESSED 4" SQ BOX WITH

1.

NOTE:

STATION CATERGORY 6 CABLING.

COMMUNICATIONS INSTALLER TO DO PROPER COMMUNICATIONS FOR WORK-

WORKSTATION SERVICE ENTRANCE BACKBOX WITH BLANK FACEPLATE FOR

PROVIDE CONNECTOR, BUSHING AND RECESSED 12"X12"X4" COMMUNICATION

FOR 120V CIRCUITS

1" EMT RECESSED

WORKSTATION SERVICE ENTRANCE DROP DETAIL

HARDWARE TO BE STAINLESS STEEL

CLAMPING NUT WITH SPRING; ALL

FLAT WASHER, LOCK WASHER AND

TRAY HOLD DOWN CLAMP WITH BOLT,

INDICATED ON DRAWINGS

CABLE TRAY, SIZE AS

LBS PER LINEAL FOOT LOAD

OF FLOOR ABOVE TO SUPPORT 330

EXPANSION ANCHORS TO UNDERSIDE

(WHERE APPLICABLE)

DROP CEILING

DRAWINGS

INDICATED ON

HEIGHT AS

E X

IS

T S

C E

IL

IN

G

(W H

E

FLOOR DECK ABOVE

UNDERSIDE OF

PIN NO. WIRE COLOR

1 WHITE/ORANGE

2 ORANGE

3 WHITE/GREEN

4 BLUE

5 WHITE/BLUE

6 GREEN

7 WHITE/BROWN

8 BROWN

1 2 3 4 5 6 7 8

W-O O W-G W-BLBL G W-BR BR

PAIR 1

PAIR 3

PAIR 2 PAIR 4

(2) 1-1/4" CONDUITS

BEHIND FINISHED

RECESSED A/V

SERVICE BOX. FSR

WB-X2 OR EQUAL

FINISHED

WALL

FINISHED FLOOR

CEILING

CABLE TRAY (TYP)

120 VAC INPUT

MONITOR

OR TV

MONITOR

OR TV

TERMINATION LEGEND

CAT6 EIA 568B WIRE

C2 SCALE : NTS

T568B MODULAR CONNECTOR

M

IN

SLOTTED CHANNEL (TYP)

GALVANIZED METAL

A2 SCALE : NTS

RODS TO BE EQUIPPED WITH PVC SLEEVES

FASTENED ON THREADED RODS. THREADED

INSTALL PLASTIC ACORN NUT ON ALL NUTS

STAINLESS STEEL EXCEPT THREADED ROD.

LINEAL FOOT LOAD. ALL HARDWARE TO BE

NUT WITH SPRING TO SUPPORT 330 LBS PER

FLAT WASHER, LOCK WASHER AND CLAMPING

THREADED ROD WITH DOUBLE LOCKNUTS,

OVERHEAD CABLE TRAY SUPPORT

A4

SCALE : NTS

COMMUNICATIONS PORT DETAIL

S E

E N

O T

E

S E

E N

O T

E

OUTLET

DATA

CEILING

6" ABOVE

WALL

NOTE:

GOVERNMENT BASED ON MONITOR HEIGHTS.

HEIGHT OF TV BOXES TO BE FIELD VERIFYED BY

C4 SCALE : NTS

RECESSED A/V JUNCTION BOX DETAIL (NON STC RATED WALL)

"B"

2.

3.

"A"

STATION INPUT

MONITOR OR TV BOX IS TYPE "A" ON PLANS

STATION INPUT BOX IS TYPE "B" ON PLANS

"A"

1.

X-XXX

X-XXX

X-XXX

X-XXXX-XXX

/2

/2

BOXES AND INTO FLOOR BOX

RACEWAY CONNECTION TO OTHER "B" WALL

CONFERENCE ROOM SOUTH TO ALLOW

ALONG COLUMN 8 TO ONLY BE IN

BELOW BOX INTO EXISTING TRENCH DUCT

(2) 1 1/4" CONDUITS BEHIND FINISHED WALL

W E

K

B

L I

/1

/2

A D

M R

E V

IS

E D D

E T

A

IL

TWO CABLES AND POPULATE TWO OUTLETS

AT ALL OTHER LOCATIONS PROVIDE

WORKSTATIONS POPULATE ONE OUTLET

PROVIDE QUAD FACEPLATE AT ALL

FROM NEAREST 120VAC RECEPTACLE CIRCUIT.

HAVE A DUPLEX RECEPTACLE WITH SERVICE

SHALL ALL TYPE "A" AND TYPE "B" BOXES4.

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

C

K I S

L A

N D D

IS

T R

IC

T

C L

O C

K T

O W

E R A

N N

C L

K T

W R

B

C L

K T

W R

T -5

.d g

T-503

D F

L O

O R R

E M

O D

E L

K H

E N

N E

M

D

O R

IT

Z

LABEL (NOTE 1)

OUTLET FACEPLATE

(TYP OF 4) (NOTE 2)

OUTLET JACK LABELS

FL-SW-PORT

TIA-606-A STANDARD (NOTE 4)

TELECOM ROOM IN COMPLIANCE WITH

HORIZONTAL CABLE LABEL AT

RM-OUTLET-JACK

RM-OUTLET

RM-OUTLET-JACK

STANDARD (NOTE 3)

AREA IN COMPLIANCE WITH TIA-606-A

HORIZONTAL CABLE LABEL AT WORK

A3 SCALE : NTS

C O

M M

U N

IC

A T

IO

N S D

E T

A

IL

TYPICAL DATA OUTLET DETAIL

JACKS (RJ-45 TYPE)

8-POSITION CAT-6 #23 AWG

WORKSTATIONS

(FOUR CABLE CONFIGURATIONS) IN

FOUR-PORT MODULAR FACEPLATE

SINGLE GANG FLUSH MOUNT

OUTLET (BLUE)

CABLES PER

CAT-6 (STP) #23 AWG

FOR DATA JACKS

48 PORT HD PANEL

COORDINATE WITH OWNER

AWG VOICE OUTLET, (RJ-45 TYPE);

8-POSITION SHIELDED (STP) CAT-6 #23

PORT LABELS

PATCH PANEL

FL-SW-PORT FL-SW-PORT FL-SW-PORT FL-SW-PORT FL-SW-PORT

FL-SW-PORT FL-SW-PORT

FL-SW-PORT FL-SW-PORT

FLOOR-SWITCH ID-PORT#

OUTLET JACK LABELS WHERE:2.

FLOOR-SWITCH ID-PORT#

OUTLET FACEPLATE LABEL WHERE:1.

FLOOR-SWITCH ID-PORT#

HORIZONTAL CABLE LABEL AT TELECOM ROOM WHERE:4.

FLOOR-SWITCH ID-PORT#

HORIZONTAL CABLE LABEL AT WORK AREA WHERE:3.

TO RIGHT, TOP TO BOTTOM.

OUTLET JACKS ARE NUMBERED FROM LEFT5.

/2

/2

E

K

B

GENERAL SHEET NOTES:

L I

/1

/2

A D

M

R E

V

IS

E D D

E T

A

IL

LOCATIONS THAN MODULAR WORKSTATIONS

TWO OUTLET OPENINGS AT ALL OTHER

PROVIDE TWO CABLES AND POPULATE

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

R O

C K I S

L A

N D D

IS

T R

IC

T

R O

C K I S

L A

N D

IL

L

IN

O

IS

B5CLKTWR1802_G-001
References
_AEC ANSI D Border, PW_WORKDIR:d0757487
G-BSDxxx.dgn

AREA PLAN, B5CLKTWR1802_G-001.dgn, Model

B5CLKTWR1802_E-001 - Electrical Notes.pdf
B5CLKTWR1802_E-001
References
B, PW_WORKDIR:d0757487
G-BSDxxx.dgn

EAST ELEV, B5CLKTWR1802_E-001.dgn, Default

B5CLKTWR1802_M-601 - Mechanical Schedules.pdf
B5CLKTWR1802_M-601
References
PW_WORKDIR:d0757487
G-BSDxxx.dgn

PLAN, B5CLKTWR1802_M-601.dgn, Default

B5CLKTWR1802_E-003 - Power Plan and Communications Installation Notes.pdf
B5CLKTWR1802_E-003
References
PW_WORKDIR:d0757487
G-BSDxxx.dgn
B5CLKTWR1802_E-101 - Second Floor Power Plan.pdf
B5CLKTWR1802_E-101
References
PW_WORKDIR:d0757487
G-BSDxxx.dgn

PLAN, B5CLKTWR1802_E-101.dgn, Default

B5CLKTWR1802_E-102 - Second Floor Power Plan.pdf
B5CLKTWR1802_E-102
References
PW_WORKDIR:d0757487
G-BSDxxx.dgn

PLAN, B5CLKTWR1802_E-102.dgn, Default

B5CLKTWR1802_T-502 - Communication Details.pdf
B5CLKTWR1802_T-502
References
B, PW_WORKDIR:d0757487
G-BSDxxx.dgn
B5CLKTWR1802_T-503 - Communication Details.pdf
B5CLKTWR1802_T-503
References
B, PW_WORKDIR:d0757487
G-BSDxxx.dgn

File details come from the government source that posted it. Updated .