This is a laboratory analysis report documenting lead content testing performed on paint samples from the USACE Dworshak Project. Eurofins Built Environment Testing, located in Pasadena, Texas, conducted the analysis using Flame AA methodology per USEPA SW846 7000B/3050B (Modified). The testing was performed for Mike Lawrence at Now Environmental Services, Federal Way, Washington, with Order #4601950 and Project #S26-0509.

The single paint sample tested (Sample ID L1) was grey in color and showed lead concentration results of less than 50 ppm and less than 0.005% by weight. The sample was received on 30-Jun-2026, analyzed on 6-Jul-2026, and reported on 6-Jul-2026. The laboratory, recognized by EPA NLLAP through AIHA-LAP LLC (Lab ID: 157714), reports an estimated accuracy of ±13% based on internal control sample recovery at the 95% confidence interval, with a reporting limit of 50.0 ppm. The analysis was conducted by Analyst Alexander Benavidez under Lab Director Scott Ward, Ph.D., and is for the exclusive use of the addressed customer.

View the file

Other files

File Type Posted
GFP DWA U4-6 Bulkhead Refurb W912EF27QA002.xlsx XLSX spreadsheet
PWS W912EF27AQ002 AM 01.pdf PDF
Solicitation Amendment W912EF27QA0020001 SF 30.pdf PDF
GFP DWA U4-6 Bulkhead Refurb W912EF26QA096.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4601950

S26-0509

30-Jun-2026

6-Jul-2026

6-Jul-2026

Eurofins Built Environment Testing 3113 Red Bluff Road Pasadena, Texas 77503

Phone: (713) 290-0223 – Fax: (832) 831-5669 www.EurofinsBuiltEnv.com

Lead in Paint Performed by Flame AA – USEPA SW846 7000B/3050B (Mod.)

Project #:Now Environmental Services

Order #:Mike Lawrence

< 50

34009 9th Ave S, Suite A12

Federal Way, WA 98003

Report Date:

L1

LEAD

CONCENTRATION

Receipt Date:

Analysis Date:

Grey < 0.005%

LEAD

CONCENTRATION

(ppm)

SAMPLE

ID

PAINT

COLOR

USACE Dworshak Project

Results apply to the sample as received and relate only to the items tested. The analysis has been conducted according to the method(s) listed above. Blank corrections are not applied to data unless requested by the customer. This report is for the exclusive use of the addressed customer and shall not be reproduced except in full without written approval by Eurofins J3 Resources, Inc. (EJ3). EJ3 is an EPA NLLAP recognized lab by the AIHA-LAP, LLC ELLAP (Lab ID: 157714).

Unless otherwise noted, all quality control samples performed within specifications established by the laboratory. The estimated accuracy is solely based on recovery data from internal laboratory control samples at the 95% confidence interval (k = ~2) of the level of concern, derived from a 336.9 mg/Kg lead in paint certified reference material. The estimated accuracy does not account for uncertainty associated with the sampling process. Accuracy = +/-13%

INS = Insufficient Sample Weight NS = Not Submitted

Scott Ward, Ph.D. Lab Director

Reporting Limit = 50.0 ppm N/A = Not Applicable

Analyst: Alexander Benavidez