AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The reason for amendment 4 is to do the following:
a. Incorporate revised FID dated 8/13/2020.
b. All other terms and conditions remains unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912DY20Q0172
X 9B. DATED (SEE ITEM 11)
25-Jun-2020
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
U0004
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
14-Aug-2020
CODE
US ARMY ENGINEERING & SUPPORT CENTER
475 QUALITY CIRCLE NW
HUNTSVILLE AL 35806
W912DY 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
x 1
W912DY20Q0172
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
(End of Summary of Changes)
UH Army Furnishings Program – Furniture Item Descriptions (FID) AFH, Camp Zama, Bldg 671, Appliances
Revised 08-13-2020
Attachment 2 Page 1 of 6
Attachment #2
Furniture Item Descriptions (FID)
Army Family Housing
Revised 08-13-2020
Attachment 2 Page 2 of 6
TABLE OF CONTENTS PAGE NO.
1. GENERAL
2.-7. NOT USED
8. APPLIANCES
Attachment 2 Page 3 of 6
1. GENERAL
1.1.-1.3. Not Used.
1.4 Electrical.
Unless noted otherwise in FID, all electrical requirements shall meet the following:
a. Washing Machine, Dryer: 100V/50Hz
b. 30” Range: 220-240V/50 Hz
c. 20” Gas Range: 100-120V/60 Hz
Electrical convertors shall not be acceptable.
a. Washing Machine and Dryer plugs should be non-polarized type-A.
b. 30” Range and 20” Gas Range plugs are in photographs below.
Type A plug 20” Gas Range Plug 30” Range Plug
1.5 Cut Sheets.
Cut sheets are required for this RFQ. Items shall conform to the following requirements in order to be considered acceptable for this RFQ:
a. Cut sheets shall be legible with highlighted model numbers, dimensions, warranty information, and all salient features required in the FID.
b. All cutsheets shall be provided in 1-3 searchable PDF documents or other applicable software and be assembled and labeled in numerical order based on the FID section number, ex.: 2.1 Mattress, 3.1 Bed, etc.
c. Label each PDF with the pages contained within, ex.: Vendor’s cutsheets pgs. 1-10, Vendor’s cutsheets pgs. 11-25, etc.
d. Cut sheet shall include color photographs of all fabric selections being submitted for approval. Include fabric content, flame resistance, and abrasion resistance testing.
Attachment 2 Page 4 of 6
e. Cut sheets shall include line drawings or images that address all required features.
f. Cut sheets shall clearly state name brand, model numbers, for all items quoted.
g. Cut sheets shall clearly state all required features that have been provided. List all of the features if printed literature is not available. The features may be handwritten on the cut sheet with the name, phone number, and company of the person who is providing the information.
h. Cut sheets which have more than one model, size, type, or which show statement of line options shall be clearly marked to show the model, size, type, and all salient features proposed.
i. PDFs created using scanned documents shall use text recognition (i.e. OCR) to ensure search functions are enabled.
j. If technical documentation is not available in English, documentation shall also be submitted in English to verify requirements.
k. All products shall be compliant with the Trade Agreements Act (TAA). Vendor shall provide documentation indicating country of origin for each product to verify TAA compliance.
2.-7. NOT USED
8. APPLIANCES
Manufacturer’s warranty shall be provided. Contractor shall verify onsite that clearances are adequate for appliances.
8.1 Not Used.
8.2 30” Range.
• Multistar MER30220EUW, or equal.
a. Shall be 30"W x 25-29"D x 37-48”H.
b. Shall be electric.
c. Shall be free-standing.
d. Shall have smooth glass cook top surface.
e. Shall have a minimum capacity of 4.0 cubic feet.
f. Provide digital temperature display.
g. Oven shall have:
i. Bake and broil elements
ii. 2 Removable racks with a minimum of 4 rack positions
h. Range top shall have two 6" and two 8" burners.
i. Provide removable storage drawer.
Attachment 2 Page 5 of 6
j. Color shall be white.
k. Provide 3 wire cord.
l. Provide minimum 1 year warranty for parts and labor.
8.3 20” Gas Range.
• GE - Hotpoint RGAS200DMWW, Summit - RG200WS, or equal.
a. Shall be 20”W x 23-27”D x 40-43”H.
b. Shall be gas.
c. Shall be freestanding.
d. Shall be electric ignition.
e. Oven shall have:
i. Bake and broil elements
ii. 2 Removable racks with a minimum of 4 rack positions
iii. Minimum capacity of 2.0 cubic feet.
f. Range top shall have 4 burners.
g. Provide storage or broiler drawer.
h. Color shall be white.
i. Provide 3 wire cord.
j. Provide conversion kit for LP gas.
k. Provide connectors, hoses, vents, etc. for a fully functioning unit.
l. Provide minimum 1 year warranty for parts and labor.
8.4 Washing Machine.
• Toshiba AW-8D8, Sharp ES-PW8D, Hitachi BW-DV80E, or equal
a. Shall be 22-25”W x 22-26”D x 38-42”H.
c. Shall be Japanese model washing machine.
d. Shall have a both washing and drying features.
e. Shall have minimum washing capacity of 8 KG.
f. Shall have minimum drying capacity of 3 KG.
g. Shall have minimum of 4 washing functions.
h. Shall have water or weight and temperature sensor.
i. Shall have a stainless steel tank.
j. Shall have a function to deodorize, sanitize or clean the tank.
k. Shall be same manufacturer and style as clothes dryer provided.
l. Provide 2 wire cord.
m. Provide all supply hoses, drain lines, connectors, etc. for a functional unit.
n. Color shall be white.
Attachment 2 Page 6 of 6
o. Provide minimum 1 year warranty on parts and labor.
8.5 Clothes Dryer.
• Hitachi, DE-N60WV, Sharp KD-60C, Toshiba ED-60C-W, or equal
a. Shall be 24-26”W x 20-22”D x 22-27”H.
c. Shall be Japanese model clothes dryer.
d. Shall have minimum drying capacity of 6 KG.
e. Shall be front loading.
f. Shall have minimum of 2 drying functions.
g. Shall have humidity sensor.
h. Shall have lint filter.
i. Provide all connectors, vent kits, etc. for a functional unit.
j. Shall be same manufacturer and style as washing machine provided.
k. Shall be able to stack over washing machine.
l. Provide 2 wire cord.
m. Color shall be white.
n. Provide minimum 1 year warranty on parts and labor.
8.6 Clothes Dryer Stand, Direct Attached
• Toshiba - DS-D1, Hitachi DES-P32-S, Sharp KD-3S3-C, or equal.
a. Shall be 18-25” W x 24-30” H x 17-20”D.
b. Shall be Japanese model clothes dryer stand.
c. Shall be same manufacturer as washing machine and clothes dryer provided.
d. Shall be direct attached.
e. Shall be used with the clothes dryer to stack over washing machine.
f. Shall be made of metal.
g. Shall be height and width adjustable.
h. Shall come with all hardware necessary to install.
i. Color shall be white.
END OF SECTION
| REV 08-13-2020 - ATT 2 - FID - AFH, Camp Zama, Bldg 671, Appliances.pdf |