W912DW25Q00130001.pdf
PDF 859 KB Posted
- Solicitation number
- W912DW25Q0013
About this file
This is an amendment (SF30 form) to solicitation W912DW25Q0013 issued by the US Army Corps of Engineers Seattle District. The amendment adds drawings that were inadvertently not included in the original solicitation.
The added drawings include detailed specifications for deficient welded connections gridlines on a spillway gate upper leaf, showing dimensions and connection points between vertical ribs/purlins, horizontal girders, and web-stiffeners. Additional drawings show the upper leaf laydown/delivery layout with specifications for wood dunnage supports designed to sustain 60,000 lbs each, and cathodic protection anode layout drawings showing the placement of magnesium anodes on both upper and lower spillway gates. The drawings include specific installation notes and dimensions for proper mounting of anodes and associated hardware.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912DW25Q00130003.pdf | ||
| W912DW25Q00130002.pdf | ||
| W912DW25Q0013.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to add draw ings that w ere inadvertently not included. All other terms and conditions remain unchanged.
Accordingly, this solicitation is amended as follow s:
SEE CONTINUATION PAGE
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 27-Nov-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912DW25Q0013
X 9B. DATED (SEE ITEM 11)
27-Nov-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Nov-2024
CODE
USA ENGINEER DISTRICT, SEATTLE
ATTN: CENWS-CT
4735 EAST MARGINAL WAY SOUTH, BLDG. 1202
SEATTLE WA 98134-2388
W912DW 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912DW25Q0013
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
(End of Summary of Changes)
L
M
N
P
1 2 3 4
K
J
H
G
F
E
D
C
B
A
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
D
ES
IG
N
ED
B
Y:
D
AT
E:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D B
Y:
Fi le
P at h:
PL
O T
D
AT
E:
SI
ZE
US Army Corps of Engineers
SHEET ID
S-103
FY
P 2-
A
FD
SG
AF
D
S
PI
LL
W
AY
G
AT
E
R
EC
O
AT
IN
G
A N
D H
SS
W
EL
D
R
EP
AI
R
AL
BE
N I F
AL
LS
D
AM
, I D
AH
O
U
PP
ER
L
EA
F
W
EL
D C
O N
N R
EP
AI
R
. J
IM
EN
EZ
-D
IA
Z
R . J
IM
EN
EZ
-D
IA
Z
A.
H
EN
IN
G
ER
A
PR
IL
W
2D W
R
TE
R
ES
A
L.
K
IN
G
C :\U se rs
\g 3e nd rjj
\D oc um en ts
Va ul tW or k\ D es ig ns \C iv il
W or ks \A lb en i F al ls D am \F
Y2
Sp illw ay G at es
\D R
W \A
N
SI
-D S
TR
U
C
TU
R
AL
S H
EE
TS
_1
.id w
AN
SI
D
SE
AT
TL
E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
E
AS
T M
AR
G
IN
AL
W
AY
S O
U
TH
SE
AT
TL
E, W
AS
H
IN
G
TO
N
SECTION: DEFICIENT WELDED CONNECTIONS GRIDLINES, SPILLWAY GATE UPPER LEAF
SCALE:
B
- 1 1/2" = 4' - 0"
SECTION: DETAIL CALLOUT FOR WELDED CONNECTIONS P#-G# AND P#-S#
SCALE:
A
- 1/2" = 1' - 0"
G1
S1
S2
S3
G2
S4
S5
3' -2
1'
-1 0"
3' -2
3'
-2
3' -1
0"
2'-6" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-6"
P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16
1' 2' 4'0
A
B -
S-501
S-501
SPILLWAY GATE UPPER LEAF, LOOKING UPSTREAM
SCALE:A19 1/4" = 1' - 0"
SPILLWAY GATE UPPER LEAF, RIGHT SIDE VIEW
SCALE:A8 1/4" = 1' - 0" 2' 4' 8'0 2' 4' 8'0
B1 B2
C -
SECTION: VERTICAL END-BEAM ASSEMBLY
SCALE:
C
- 1" = 2' - 0"
1. GRIDLINES B1 TO B2 REPRESENT THE CENTERLINES OF THE VERT END-BEAMS ASSY.
2. GRIDLINES P1 TO P16 REPRESENT THE CENTERLINES OF THE VERTICAL RIBS/PURLINS.
3. GRIDLINES G1 TO G2 REPRESENT THE CENTERLINES OF THE HORIZONTAL GIRDERS.
4. GRIDLINES S1 TO S5 REPRESENT THE CENTERLINES OF THE WEB-STIFFENERS FOR THE
VERTICAL RIBS/PURLINS.
5. NOT ALL INTERSECTIONS BETWEEN THE VERTICAL AND HORIZONTAL GRIDLINES INDICATE
THE PRESENCE OF A WELDED CONNECTION. HOWEVER, A MAJORITY OF THESE LOCATIONS
DO IDENTIFY A WELDED CONNECTION.
6. THE INTERSECTIONS BETWEEN VERTICAL GRIDLINES B1 TO B2 WITH HORIZONTAL G1 AND G2
REPRESENT THE WELDED CONNECTIONS BETWEEN THE END-BEAM ASSY AND THE
HORIZONTAL GIRDERS.
7. INTERSECTIONS BETWEEN VERTICAL GRIDLINES P1 TO P16 WITH HORIZONTAL GRIDLINES G1
AND G2 REPRESENT THE WELDED CONNECTION BETWEEN THE VERTICAL RIBS AND THE
HORIZONTAL GIRDERS. INTERSECTIONS BETWEEN HORIZONTAL GRIDLINES S1 TO S5
REPRESENT THE WELDED CONNECTION BETWEEN THE VERTICAL RIBS AND
WEB-STIFFENERS. ONLY P1 AND P16 REPRESENT A WELDED CONNECTION WHEN
INTERSECTING S1 TO S5; P2 TO P15 ONLY REPRESENTS A WELDED CONNECTION WHEN
INTERSECTING S1 AND S4. DETAILS 1/S-501 AND 2/S-501 CONTAIN INFORMATION OF THESE
CONNECTIONS AND REQUIRED REPAIRS.
1' 2' 4'0
GENERAL SHEET NOTES
M
N
P
1 2 3 4
K
J
H
G
F
E
D
C
B
A
5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
D
ES
IG
N
ED
B
Y:
D
AT
E:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D B
Y:
Fi le
P at h:
PL
O T
D
AT
E:
SI
ZE
US Army Corps of Engineers
SHEET ID
S-5__
FY
P 2-
A
FD
SG
AF
D
S
PI
LL
W
AY
G
AT
E
R
EC
O
AT
IN
G
A N
D H
SS
W
EL
D
R
EP
AI
R
AL
BE
N I F
AL
LS
D
AM
, I D
AH
O
U
PP
ER
L
EA
F
LA
YD
O W
N F
O R
F R
P R
EP
AI
. J
IM
EN
EZ
-D
IA
Z
R . J
IM
EN
EZ
-D
IA
Z
J
U N
E
W
2D W
R
D
AI
SY
D
O U
G
LA
SS
C :\U se rs
\g 3e nd rjj
\D oc um en ts
Va ul tW or k\ D es ig ns \C iv il
W or ks \A lb en i F al ls D am \F
Y2
Sp illw ay G at es
\D R
W \A
N
SI
-D S
TR
U
C
TU
R
AL
S H
EE
TS
_1
_C O
N -M
O D s.
id w
AN
SI
D
SE
AT
TL
E
D
IS
TR
IC
T U
.S . A
R M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
E
AS
T M
AR
G
IN
AL
W
AY
S O
U
TH
SE
AT
TL
E, W
AS
H
IN
G
TO
N
(TYP) ADD LAYERS OF
RUBBER MATS BETWEEN
THE SKIN AND THE
LUMBER.
- REFER TO NOTE 2 & 11
(TYP) ADD LAYERS OF RUBBER
MATS BETWEEN THE SKIN AND
THE LUMBER.
- REFER TO NOTE 2 & 11
12"
8"
WOOD DUNNAGE - 4X4
-REFER TO NOTE 1
4"
'-0
R O
W S
' O .C
T
O
TA
L= 2'
-0
TY
P)
2"
2"
(TYP) INSTALL 3/4"Ø -
7" LONG WOOD SCREWS
(FOR EXTERIOR USE).
-REFER TO NOTE 1, 3 & 4
UPPER LEAF LAYDOWN/DELIVERY LAYOUT - TOP, BACK & SIDE VIEWS
SCALE:E2 1/2" = 1' - 0" 1' 2' 4'0
1. DESIGN DUNNAGE SETS OR SUPPORTS TO SUSTAIN 60,000-LBS. EACH DUNNAGE SET, OR SUPPORT CAN BE CREATED WITH 4X4 LUMBER AS SHOWN OR LARGER.
VERIFY CURRENT CONFIGURATION OF DUNNAGE/SUPPORTS IS ADEQUATE FOR THIS SCENARIO.
2. SECURE/ATTACH THE RUBBER MATS TO THE LUMBER. ENSURE THE ATTACHMENT OF THE RUBBER MATS DOES NOT DAMAGE THE COATING ON THE SKINS.
ATTACHMENT CONFIGURATION SHOWN HEREIN IS JUST AN EXAMPLE AND MUST NOT BE USED UNLESS EVALUATED AND APPROVED BY A QUALIFIED SUPPLIER.
3. DRAWING SHOWS A POSSIBLY CONFIGURATION OF 4X4 LUMBER THAT WILL REQUIRE SCREW INSTALLATION TO STABILIZE THE PIECES OF LUMBER THAT CREATE
THE SUPPORT. VERIFY CURRENT CONFIGURATION OF SCREWS AND LUMBER ARE ADEQUATE FOR THIS SCENARIO. AS MENTIONED IN NOTE 1, IF LARGER
CROSS-SECTION LUMBER IS USED, SCREWS REQUIREMENTS CAN BE MODIFIED OR ELIMINATED.
4. INSTALL SAME NUMBER OF SCREWS IN BOTH SIDES OF EACH DUNNAGE SET OR SUPPORTS, FOR THE OPPOSITE SIDE CHANGE BOTTOM EDGE DISTANCE TO 4" TO
AVOID INTERFERENCE FROM OTHER SIDE FASTENERS. REFER TO NOTE 3 FOR ADDITIONAL INFORMATION
5. ENSURE THAT DUNNAGE PLACEMENT DOES NOT INTERFERE WITH CATHODIC ANODES ON THE FACE OF THE GATE
6. ENSURE THAT ALL ELEMENTS OF THE GATE ARE SECURED AND THERE IS AMPLE ROOM AROUND THE GATE FOR PERSONNEL AND VEHICLE ACCESS
7. PROVIDE FLAGGING AROUND THE PERIMETER
8. WHEN THE GATE IS READY TO BE INSTALLED, HAVE A THROUGH PLAN TO INSPECT THE SKIN FACE OF THE GATE TO ENSURE NO DAMAGE HAS OCCURRED ON THE
COATING.
9. ONCE UPPER LEAF IS REPAIRED BUT BEFORE ROTATING IT TO THE VERTICAL POSITION, ENSURE PROPER DUNNAGE AND RUBBER MATS ARE PLACED AT THE
ROTATION POINTS, WHICH ARE AT THE BOTTOM PLATES OF EACH VERTICAL-BEAM-ASSY.
10. FINAL DUNNAGE AND RUBBER MATS SETUP AND MATERIAL GRADE MUST BE DESIGNED AND APPROVED BY A QUALIFIED SUPPLIER.
11. QUANTITY OF MAT LAYERS AND THICKNESS MUST BE DESIGNED AND APPROVED BY A QUALIFIED SUPPLIER.
GENERAL SHEET NOTES
(TYP) INSTALL 3/4"Ø -
7" LONG WOOD SCREWS
(FOR EXTERIOR USE).
-REFER TO NOTE 1 & 3
4"
'-0
R O
W S
' O .C
T
O
TA
L= 2' -0
TY
P)
4/20/22
S O
L I C
I T
A T
I O
N
N
O
D
2 3
C
4 5
A
B
M A
R K
S I Z
E
S U
B M
I T
T E
D
B
Y
D E
S C
R I P
T I O
N
C O
N T
R A
C T
N
O
D A
T E
E
A S
T
M
A R
G I N
A L
W
A Y
U
T H
S E
A T
T
E
D
I S
T R
I C
T
S E
A T
T L E
W
A S
H I N
G T
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
R M
F
O R
T N
E R
J C
P
I E
R C
E
N J T
D
O D
S O
N
F X
X X
X
D E
C E
M B
A N
S I
D
W J
K
N A
P P
D
A T
E
T
I M
E
W X
X X
X X
F Y
P
A
F D
S G
A F
D
S
P I L L W
G
T
E
R E
C O
A T
I N
G
A
H
W
P
A I R
A L B
E N
I
F
A L
M
I D
A H
O
D E
S I G
N E
D
B
G
E
109876
US Army Corps of Engineers
SHEET ID
I S
S U
E
D
A T
E
F i l e a t h
D G
N
P l o t
D a t e
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
F I
U M
B E
R
11 12 13 14 15 16 17 18 19 20
H
J
K
L
M
N
P
M O
B I L E
A
L A
B A
M A
M O
B I
S
T R
I C
T
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
3/8" = 1'-0"
UPPER GATE, UPSTREAM SIDE - CATHODIC PROTECTION ANODE LAYOUT
A
4'0 2' 8'
GENERAL INSTALLATION NOTES FOR ALL GALVANIC (MAGNESIUM) ANODES:
1. THERE ARE 11 GATES IN TOTAL, EACH WITH AN UPPER AND LOWER LEAF.
CATHODIC PROTECTION SHALL BE INSTALLED AS SHOWN (ON THESE
CATHODIC PROTECTION PLANS) ON EACH AND ALL OF THE SPILLWAY
GATES.
2. PRIOR TO PAINTING (COATING) THE GATES, PERFORM ALL REQUIRED
WELDING OF MOUNTING BOLTS, ROUTING CLAMPS, AND ANY OTHER
REQUIRED WELDING, TO BE ACCOMPLISHED AS SHOWN IN THE ANODE
MOUNTING DETAILS AND IN THE LOCATIONS AS SHOWN IN THE CATHODIC
PROTECTION PLAN AND LAYOUT DRAWINGS. WRAP THE MOUNTING BOLT
THREADS WITH TAPE TO PREVENT THE GATE COATING MATERIAL FROM
ADHERING TO THE THREADS. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR'S CORROSION ENGINEER (AS SPECIFIED IN 26 42 14.00 10,
CATHODIC PROTECTION SYSTEMS (SACRIFICIAL ANODE)) TO COORDINATE
THE EXACT LOCATIONS OF THE ANODE MOUNTING BOLTS, ETC., WITH THE
ANODE SUPPLIER AND THE EXISTING GATE..
3. THE GATE SHALL BE PAINTED IN ACCORDANCE WITH SPECIFICATION 09 97
02.00 25, PAINTING: HYDRAULIC STRUCTURES.
4. ONCE THE GATES ARE PAINTED, AND IMMEDIATELY PRIOR TO INSTALLING
THE ANODES, REMOVE THE TAPE FROM THE BOLTS. REMOVE ANY PAINT
FROM THE THREAD SIDE OF THE MOUNTING BOLT HEAD. BEFORE
MOUNTING THE ANODES, REMOVE THE EPOXY COATING FROM THE AREA
ADJACENT TO THE ANODE MOUNTING HOLES. THESE PROCEDURES MUST
BE ACCOMPLISHED IN ORDER TO INSURE PROPER ELECTRICAL CONTACT
BETWEEN THE ANODE STRAP, BOLT, NUTS, AND WASHERS.
5. AFTER EACH ANODE IS INSTALLED, REMOVE THE PLASTISOL COATING FROM
THE HULL MAGNESIUM ANODE SURFACE AS DETAILED IN THESE CATHODIC
PROTECTION DRAWINGS FOR THE SPECIFIC ANODES BEING INSTALLED.
THEN CHECK THE CONTINUITY BETWEEN THE ANODE AND GATE
STRUCTURAL STEEL. DISCONTINUOUS ANODES ARE TO BE REMOVED,
POINTS OF CONNECTIONS CLEANED OF ANY EXCESS EPOXY OR PAINT, AND
THEN REINSTALLED AS REQUIRED TO ACHIEVE THE DESIRED CONTINUITY.
6. AFTER ANODE INSTALLATION, ALL EXPOSED STEEL SURFACES (INCLUDING
BOLTS, NUTS, WASHERS, STRAPS, AND ROUTING CLAMPS) SHALL BE
THOROUGHLY CLEANED AND PAINTED USING PAINTS AND COATINGS
PRESCRIBED FOR GATE (SEE SPECIFICATION 09 97 02.00 25, PAINTING:
HYDRAULIC STRUCTURES). CARE SHOULD BE TAKEN TO NOT PAINT ANY OF
THE MAGNESIUM ANODE MATERIAL.
7. MINOR ADJUSTMENT OF ANODE LOCATIONS SHALL BE ACCOMPLISHED, AS
COORDINATED WITH THE CONTRACTOR'S CORROSION ENGINEER, IN ORDER
TO AVOID CONFLICT WITH OTHER GATE STRUCTURAL OR MECHANICAL
COMPONENTS AND/OR OTHER OBSTACLES.
8. THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A CORROSION
ENGINEER TO SUPERVISE, COORDINATE, TEST, AND PERFORM ALL OTHER
SERVICES AS REQUIRED BY THE SPECIFICATIONS IN ORDER TO INSURE
THAT ALL ASPECTS OF THE CATHODIC PROTECTION LAYOUT AND
INSTALLATION ARE IN FULL COMPLIANCE WITH THE SPECIFICATION 26 42
14.00 10, CATHODIC PROTECTION SYSTEMS (SACRIFICIAL ANODE), AND
ACCEPTABLE INDUSTRY STANDARDS. THE CONTRACTOR'S CORROSION
ENGINEER SHALL COORDINATE WITH THE CATHODIC PROTECTION ANODE
SUPPLIER AND THE GENERAL CONTRACTOR TO INSURE THAT OPERATION
OF THE GATE IS NOT HINDERED, IN ANY MANNER, DUE TO THE MOUNTING
LOCATIONS OF ANODES. ANY MODIFICATIONS TO THE CATHODIC
PROTECTION SYSTEM SHALL BE SUBMITED BY THE CONTRACTOR'S
CORROSION ENGINEER, VIA THE CONTRACTOR, TO THE GOVERNMENT FOR
APPROVAL, PRIOR TO ACCOMPLISHING THE WORK.
9. TWO (2) SPARE ANODES OF EACH TYPE SHALL BE FURNISHED PER GATE
LEAF.
3/8" = 1'-0"
LOWER GATE, UPSTREAM SIDE - CATHODIC PROTECTION ANODE LAYOUT
B
4'0 2' 8'
24 POUND MAGNESIUM
ANODE, TYPICAL
NOTE: THE ABOVE VIEWS SHOW THE CATHODIC PROTECTION LAYOUT OF THE
SKIN PLATE (UPSTREAM) SIDE OF ONE UPPER AND LOWER SPILLWAY GATE.
6'-11" 6'-11" 6'-11" 6'-11"
GATE
MAGNESIUM ROD
ANODE, TYPICAL
SKIN PLATE
6'-11" 6'-11" 6'-11" 6'-11"
GATE
24 POUND MAGNESIUM
ANODE, TYPICAL
MAGNESIUM ROD
ANODE, TYPICAL
SKIN PLATE
A
CP501
A
CP501
D
CP501
VIBRATION-DAMPING
ROUTING CLAMP
VIBRATION-DAMPING
ROUTING CLAMP
D
CP501
1'-0"
CP103
A
UPPER GATE ROLLER
ASSEMBLY
CP103
C
LOWER GATE ROLLER
ASSEMBLY
CP103
C
CP103
B
CP103
A
CP103
C
CP103
C
CP103
B
O.H.
O.H.
O.H.
O.H.
C A
T H
O D
C
O
T E
C T
I O
N
A N
O D
E
L
A Y
O U
T
CP101
5"
1'-0"
5"
NOTE: ROD ANODE
DIMENSIONS TYPICAL
BOTH SIDES
NOTE: ROD ANODE
DIMENSIONS TYPICAL
BOTH SIDES
W
2D W
R
File details come from the government source that posted it. Updated .